1
|
Zhou Z, Wei D, Azhe S, Fu C, Zhou X, An J, Piccini D, Bastiaansen J, Guo Y, Wen L. Self-navigated coronary MR angiography for coronary aneurysm detection in Kawasaki disease at 3T: comparison with conventional diaphragm-navigated coronary MR angiography. Eur Radiol 2024; 34:3400-3410. [PMID: 37857903 DOI: 10.1007/s00330-023-10350-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 07/26/2023] [Accepted: 08/24/2023] [Indexed: 10/21/2023]
Abstract
OBJECTIVES To assess the scan time, image quality, and diagnostic performance of self-navigated coronary MR angiography (SN-CMRA) for coronary aneurysm (CAA) detection in Kawasaki disease (KD) patients and compare it with diaphragm-navigated CMRA (DN-CMRA). MATERIALS AND METHODS SN-CMRA and DN-CMRA were performed on 76 pediatric patients with KD (48 males, 6.75 ± 3.59 years). Thirty-three of whom underwent coronary CT angiography (CCTA)/invasive coronary angiography (ICA). The scan time and qualitative and quantitative image quality assessment were compared between the two sequences. The diagnostic performance for CAA detection by the two approaches using CCTA/ICA as the reference standard was compared on per-patient, per-vessel, and per-segment basis. RESULTS The scan time of SN-CMRA was significantly shorter than that of DN-CMRA (7.49 ± 2.31 min vs. 10.03 ± 4.47 min, p < 0.001). There was no difference in overall and segmental image quality to reach the clinical diagnostic criteria between the two sequences (all p > 0.05). No significant difference in vessel length of the three main coronary arteries was found between the two approaches (all p > 0.05). Moreover, SN-CMRA showed no difference from DN-CMRA in contrast ratio of blood-myocardium (1.25 (interquartile range [IQR], 1.06 to 1.51) vs. 1.18 (IQR, 0.95 to 1.64), p = 0.706). There was no difference in the diagnostic accuracy of SN-CMRA and DN-CMRA for CAA detection on per-patient, per-vessel, or per-segment basis (all p > 0.05). CONCLUSION SN-CMRA at 3T showed reliable diagnostic performance and application value for CAA detection in children with KD. Compared with DN-CMRA, SN-CMRA can simplify the scanning procedure and shorten the scan time, achieving comparable image quality and diagnostic accuracy. CLINICAL RELEVANCE STATEMENT Coronary aneurysm in children with Kawasaki disease (KD) can be detected by self-navigated coronary MR angiography (CMRA) non-invasively and without radiation, achieving comparable image quality and diagnostic performance as diaphragm-navigated CMRA while shortening scanning time. It can provide reference for risk stratification and treatment management of KD. KEY POINTS • Evaluating the size of coronary aneurysm is important for risk stratification and treatment of Kawasaki disease. • Self-navigated coronary MR angiography (SN-CMRA) shortens scan time and achieves comparable image quality and diagnostic performance compared with diaphragm-navigated coronary MR angiography. • SN-CMRA can evaluate coronary aneurysm non-invasively and without radiation, providing information for risk stratification and treatment.
Collapse
Affiliation(s)
- Zhongqin Zhou
- Department of Radiology, Key Laboratory of Birth Defects and Related Diseases of Women and Children (Sichuan University), Ministry of Education, West China Second University Hospital, Sichuan University, Chengdu, 610041, Sichuan Province, China
| | - Dongmei Wei
- Department of Gynecology and Obstetrics, Key Laboratory of Birth Defects and Related Diseases of Women and Children (Sichuan University), West China Second Hospital, Sichuan University, Chengdu, China
| | - Shiganmo Azhe
- Department of Radiology, Key Laboratory of Birth Defects and Related Diseases of Women and Children (Sichuan University), Ministry of Education, West China Second University Hospital, Sichuan University, Chengdu, 610041, Sichuan Province, China
| | - Chuan Fu
- Department of Radiology, Key Laboratory of Birth Defects and Related Diseases of Women and Children (Sichuan University), Ministry of Education, West China Second University Hospital, Sichuan University, Chengdu, 610041, Sichuan Province, China
| | - Xiaoyue Zhou
- Siemens Healthineers Digital Technology (Shanghai) Co., Ltd., Shanghai, 200131, China
| | - Jing An
- Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, China
| | - Davide Piccini
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland
| | - Jessica Bastiaansen
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, University Hospital Bern, University of Bern, Bern, Switzerland
- Translation Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
| | - Yingkun Guo
- Department of Radiology, Key Laboratory of Birth Defects and Related Diseases of Women and Children (Sichuan University), Ministry of Education, West China Second University Hospital, Sichuan University, Chengdu, 610041, Sichuan Province, China
| | - Lingyi Wen
- Department of Radiology, Key Laboratory of Birth Defects and Related Diseases of Women and Children (Sichuan University), Ministry of Education, West China Second University Hospital, Sichuan University, Chengdu, 610041, Sichuan Province, China.
| |
Collapse
|
2
|
Renz DM, Böttcher J, Eckstein J, Huisinga C, Pfeil A, Lücke C, Gutberlet M. [Imaging of congenital heart defects with a focus on magnetic resonance imaging and computed tomography]. RADIOLOGIE (HEIDELBERG, GERMANY) 2024; 64:382-391. [PMID: 38656344 DOI: 10.1007/s00117-024-01301-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 03/19/2024] [Indexed: 04/26/2024]
Abstract
CLINICAL ISSUE Due to advances in diagnostics and therapy, the survival rate of patients with congenital heart defects is continuously increasing. The aim of this review is to compare various imaging modalities that are used in the diagnosis of congenital heart defects. METHODS Transthoracic echocardiography is the imaging method of choice in the presence of a congenital heart defect because of its wide availability and non-invasiveness. It can be complemented by transesophageal echocardiography, cardiac catheterization, computed tomography (CT), and magnetic resonance imaging (MRI) of the heart and vessels close to the heart. METHODICAL INNOVATIONS The radiation exposure of CT examinations of the heart is continuously decreasing because of improved technologies. MRI is also being continuously optimized, e.g., by the acquisition of MR angiographies without contrast medium application or a thin three-dimensional (3D) visualization of the entire heart with the possibility of reconstruction in all spatial planes (whole-heart technique) as well as 2D to 4D flow. PRACTICAL RECOMMENDATION Due to the complexity of congenital heart defects and the variety of possible pathologies, the choice of imaging modality and its exact performance has to be coordinated in an interdisciplinary context and individually adapted.
Collapse
Affiliation(s)
- Diane Miriam Renz
- Institut für Diagnostische und Interventionelle Radiologie, Arbeitsbereich Kinderradiologie, Medizinische Hochschule Hannover, Carl-Neuberg-Str. 1, 30625, Hannover, Deutschland.
| | | | - Jan Eckstein
- Institut für Diagnostische und Interventionelle Radiologie, Arbeitsbereich Kinderradiologie, Medizinische Hochschule Hannover, Carl-Neuberg-Str. 1, 30625, Hannover, Deutschland
| | - Carolin Huisinga
- Institut für Diagnostische und Interventionelle Radiologie, Arbeitsbereich Kinderradiologie, Medizinische Hochschule Hannover, Carl-Neuberg-Str. 1, 30625, Hannover, Deutschland
| | - Alexander Pfeil
- Klinik für Innere Medizin III, Universitätsklinikum Jena, Jena, Deutschland
| | - Christian Lücke
- Abteilung für Diagnostische und Interventionelle Radiologie, Universität Leipzig - Herzzentrum Leipzig, Leipzig, Deutschland
| | - Matthias Gutberlet
- Abteilung für Diagnostische und Interventionelle Radiologie, Universität Leipzig - Herzzentrum Leipzig, Leipzig, Deutschland
| |
Collapse
|
3
|
Vollbrecht TM, Bissell MM, Kording F, Geipel A, Isaak A, Strizek BS, Hart C, Barker AJ, Luetkens JA. Fetal Cardiac MRI Using Doppler US Gating: Emerging Technology and Clinical Implications. Radiol Cardiothorac Imaging 2024; 6:e230182. [PMID: 38602469 PMCID: PMC11056758 DOI: 10.1148/ryct.230182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 02/13/2024] [Accepted: 02/27/2024] [Indexed: 04/12/2024]
Abstract
Fetal cardiac MRI using Doppler US gating is an emerging technique to support prenatal diagnosis of congenital heart disease and other cardiovascular abnormalities. Analogous to postnatal electrocardiographically gated cardiac MRI, this technique enables directly gated MRI of the fetal heart throughout the cardiac cycle, allowing for immediate data reconstruction and review of image quality. This review outlines the technical principles and challenges of cardiac MRI with Doppler US gating, such as loss of gating signal due to fetal movement. A practical workflow of patient preparation for the use of Doppler US-gated fetal cardiac MRI in clinical routine is provided. Currently applied MRI sequences (ie, cine or four-dimensional flow imaging), with special consideration of technical adaptations to the fetal heart, are summarized. The authors provide a literature review on the clinical benefits of Doppler US-gated fetal cardiac MRI for gaining additional diagnostic information on cardiovascular malformations and fetal hemodynamics. Finally, future perspectives of Doppler US-gated fetal cardiac MRI and further technical developments to reduce acquisition times and eliminate sources of artifacts are discussed. Keywords: MR Fetal, Ultrasound Doppler, Cardiac, Heart, Congenital, Obstetrics, Fetus Supplemental material is available for this article. © RSNA, 2024.
Collapse
Affiliation(s)
- Thomas M. Vollbrecht
- From the Department of Diagnostic and Interventional Radiology,
University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (T.M.V., A.I.,
C.H., J.A.L.); Quantitative Imaging Laboratory Bonn (QILaB), University Hospital
Bonn, Bonn, Germany (T.M.V., A.I., C.H., J.A.L.); Department of Biomedical
Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine,
University of Leeds, Leeds, United Kingdom (M.M.B.); Northh Medical, Hamburg,
Germany (F.K.); Departments of Obstetrics and Prenatal Medicine (A.G., B.S.S.)
and Pediatric Cardiology (C.H.), University Hospital Bonn, Bonn, Germany;
Department of Radiology, University of Colorado Anschutz Medical Campus, Aurora,
Colo (A.J.B.); Department of Pediatric Radiology, Children’s Hospital
Colorado, Aurora, Colo (A.J.B.)
| | - Malenka M. Bissell
- From the Department of Diagnostic and Interventional Radiology,
University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (T.M.V., A.I.,
C.H., J.A.L.); Quantitative Imaging Laboratory Bonn (QILaB), University Hospital
Bonn, Bonn, Germany (T.M.V., A.I., C.H., J.A.L.); Department of Biomedical
Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine,
University of Leeds, Leeds, United Kingdom (M.M.B.); Northh Medical, Hamburg,
Germany (F.K.); Departments of Obstetrics and Prenatal Medicine (A.G., B.S.S.)
and Pediatric Cardiology (C.H.), University Hospital Bonn, Bonn, Germany;
Department of Radiology, University of Colorado Anschutz Medical Campus, Aurora,
Colo (A.J.B.); Department of Pediatric Radiology, Children’s Hospital
Colorado, Aurora, Colo (A.J.B.)
| | - Fabian Kording
- From the Department of Diagnostic and Interventional Radiology,
University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (T.M.V., A.I.,
C.H., J.A.L.); Quantitative Imaging Laboratory Bonn (QILaB), University Hospital
Bonn, Bonn, Germany (T.M.V., A.I., C.H., J.A.L.); Department of Biomedical
Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine,
University of Leeds, Leeds, United Kingdom (M.M.B.); Northh Medical, Hamburg,
Germany (F.K.); Departments of Obstetrics and Prenatal Medicine (A.G., B.S.S.)
and Pediatric Cardiology (C.H.), University Hospital Bonn, Bonn, Germany;
Department of Radiology, University of Colorado Anschutz Medical Campus, Aurora,
Colo (A.J.B.); Department of Pediatric Radiology, Children’s Hospital
Colorado, Aurora, Colo (A.J.B.)
| | - Annegret Geipel
- From the Department of Diagnostic and Interventional Radiology,
University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (T.M.V., A.I.,
C.H., J.A.L.); Quantitative Imaging Laboratory Bonn (QILaB), University Hospital
Bonn, Bonn, Germany (T.M.V., A.I., C.H., J.A.L.); Department of Biomedical
Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine,
University of Leeds, Leeds, United Kingdom (M.M.B.); Northh Medical, Hamburg,
Germany (F.K.); Departments of Obstetrics and Prenatal Medicine (A.G., B.S.S.)
and Pediatric Cardiology (C.H.), University Hospital Bonn, Bonn, Germany;
Department of Radiology, University of Colorado Anschutz Medical Campus, Aurora,
Colo (A.J.B.); Department of Pediatric Radiology, Children’s Hospital
Colorado, Aurora, Colo (A.J.B.)
| | - Alexander Isaak
- From the Department of Diagnostic and Interventional Radiology,
University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (T.M.V., A.I.,
C.H., J.A.L.); Quantitative Imaging Laboratory Bonn (QILaB), University Hospital
Bonn, Bonn, Germany (T.M.V., A.I., C.H., J.A.L.); Department of Biomedical
Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine,
University of Leeds, Leeds, United Kingdom (M.M.B.); Northh Medical, Hamburg,
Germany (F.K.); Departments of Obstetrics and Prenatal Medicine (A.G., B.S.S.)
and Pediatric Cardiology (C.H.), University Hospital Bonn, Bonn, Germany;
Department of Radiology, University of Colorado Anschutz Medical Campus, Aurora,
Colo (A.J.B.); Department of Pediatric Radiology, Children’s Hospital
Colorado, Aurora, Colo (A.J.B.)
| | - Brigitte S. Strizek
- From the Department of Diagnostic and Interventional Radiology,
University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (T.M.V., A.I.,
C.H., J.A.L.); Quantitative Imaging Laboratory Bonn (QILaB), University Hospital
Bonn, Bonn, Germany (T.M.V., A.I., C.H., J.A.L.); Department of Biomedical
Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine,
University of Leeds, Leeds, United Kingdom (M.M.B.); Northh Medical, Hamburg,
Germany (F.K.); Departments of Obstetrics and Prenatal Medicine (A.G., B.S.S.)
and Pediatric Cardiology (C.H.), University Hospital Bonn, Bonn, Germany;
Department of Radiology, University of Colorado Anschutz Medical Campus, Aurora,
Colo (A.J.B.); Department of Pediatric Radiology, Children’s Hospital
Colorado, Aurora, Colo (A.J.B.)
| | - Christopher Hart
- From the Department of Diagnostic and Interventional Radiology,
University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (T.M.V., A.I.,
C.H., J.A.L.); Quantitative Imaging Laboratory Bonn (QILaB), University Hospital
Bonn, Bonn, Germany (T.M.V., A.I., C.H., J.A.L.); Department of Biomedical
Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine,
University of Leeds, Leeds, United Kingdom (M.M.B.); Northh Medical, Hamburg,
Germany (F.K.); Departments of Obstetrics and Prenatal Medicine (A.G., B.S.S.)
and Pediatric Cardiology (C.H.), University Hospital Bonn, Bonn, Germany;
Department of Radiology, University of Colorado Anschutz Medical Campus, Aurora,
Colo (A.J.B.); Department of Pediatric Radiology, Children’s Hospital
Colorado, Aurora, Colo (A.J.B.)
| | - Alex J. Barker
- From the Department of Diagnostic and Interventional Radiology,
University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (T.M.V., A.I.,
C.H., J.A.L.); Quantitative Imaging Laboratory Bonn (QILaB), University Hospital
Bonn, Bonn, Germany (T.M.V., A.I., C.H., J.A.L.); Department of Biomedical
Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine,
University of Leeds, Leeds, United Kingdom (M.M.B.); Northh Medical, Hamburg,
Germany (F.K.); Departments of Obstetrics and Prenatal Medicine (A.G., B.S.S.)
and Pediatric Cardiology (C.H.), University Hospital Bonn, Bonn, Germany;
Department of Radiology, University of Colorado Anschutz Medical Campus, Aurora,
Colo (A.J.B.); Department of Pediatric Radiology, Children’s Hospital
Colorado, Aurora, Colo (A.J.B.)
| | - Julian A. Luetkens
- From the Department of Diagnostic and Interventional Radiology,
University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (T.M.V., A.I.,
C.H., J.A.L.); Quantitative Imaging Laboratory Bonn (QILaB), University Hospital
Bonn, Bonn, Germany (T.M.V., A.I., C.H., J.A.L.); Department of Biomedical
Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine,
University of Leeds, Leeds, United Kingdom (M.M.B.); Northh Medical, Hamburg,
Germany (F.K.); Departments of Obstetrics and Prenatal Medicine (A.G., B.S.S.)
and Pediatric Cardiology (C.H.), University Hospital Bonn, Bonn, Germany;
Department of Radiology, University of Colorado Anschutz Medical Campus, Aurora,
Colo (A.J.B.); Department of Pediatric Radiology, Children’s Hospital
Colorado, Aurora, Colo (A.J.B.)
| |
Collapse
|
4
|
McMahon CJ, Milanesi O, Pitkänen-Argillander O, Albert-Brotons DC, Michel-Behnke I, Voges I, Sendzikaite S, Heying R. Assessment for learning of paediatric cardiology trainees in 41 centres from 19 European countries. Cardiol Young 2024; 34:588-596. [PMID: 37641941 DOI: 10.1017/s1047951123003098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/31/2023]
Abstract
BACKGROUND Limited data exist on how trainees in paediatric cardiology are assessed among countries affiliated with the Association of European Paediatric and Congenital Cardiology. METHODS A structured and approved questionnaire was circulated to educationalists/trainers in 95 Association for European Paediatric and Congenital Cardiology training centres. RESULTS Trainers from 46 centres responded with complete data in 41 centres. Instructional design included bedside teaching (41/41), didactic teaching (38/41), problem-based learning (28/41), cardiac catheterisation calculations (34/41), journal club (31/41), fellows presenting in the multidisciplinary meeting (41/41), fellows reporting on echocardiograms (34/41), clinical simulation (17/41), echocardiography simulation (10/41), and catheterisation simulation (3/41). Assessment included case-based discussion (n = 27), mini-clinical evaluation exercise (mini-CEX) (n = 12), directly observed procedures (n = 12), oral examination (n = 16), long cases (n = 11), written essay questions (n = 6), multiple choice questions (n = 5), and objective structured clinical examination (n = 2). Entrustable professional activities were utilised in 10 (24%) centres. Feedback was summative only in 17/41 (41%) centres, formative only in 12/41 (29%) centres and a combination of formative and summative feedback in 10/41 (24%) centres. Written feedback was provided in 10/41 (24%) centres. Verbal feedback was most common in 37/41 (90 %) centres. CONCLUSION There is a marked variation in instructional design and assessment across European paediatric cardiac centres. A wide mix of assessment tools are used. Feedback is provided by the majority of centres, mostly verbal summative feedback. Adopting a programmatic assessment focusing on competency/capability using multiple assessment tools with regular formative multisource feedback may promote assessment for learning of paediatric cardiology trainees.
Collapse
Affiliation(s)
- Colin J McMahon
- Department of Paediatric Cardiology, Children's Health Ireland at Crumlin, Dublin, Ireland
- School of Medicine, University College Dublin, Belfield, Dublin 4, Ireland
- School of Health Professions Education (SHE), Maastricht University, Maastricht, Netherlands
| | - Ornella Milanesi
- Paediatric Cardiac Unit, Department of Paediatrics, University of Padova, School of Medicine, Padua, Italy
| | | | | | - Ina Michel-Behnke
- Division of Pediatric Cardiology, University Hospital for Children and Adolescent Medicine, Paediatric Heart Centre, Medical University Vienna, Vienna, Austria
| | - Inga Voges
- Department for Congenital Heart Disease and Paediatric Cardiology, University Hospital Schleswig Holstein, Kiel, Germany
| | | | - Ruth Heying
- Department of Paediatric Cardiology, University Hospital Leuven, Leuven, Belgium
| |
Collapse
|
5
|
Vollbrecht TM, Hart C, Zhang S, Katemann C, Sprinkart AM, Isaak A, Attenberger U, Pieper CC, Kuetting D, Geipel A, Strizek B, Luetkens JA. Deep learning denoising reconstruction for improved image quality in fetal cardiac cine MRI. Front Cardiovasc Med 2024; 11:1323443. [PMID: 38410246 PMCID: PMC10894983 DOI: 10.3389/fcvm.2024.1323443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 01/10/2024] [Indexed: 02/28/2024] Open
Abstract
Purpose This study aims to evaluate deep learning (DL) denoising reconstructions for image quality improvement of Doppler ultrasound (DUS)-gated fetal cardiac MRI in congenital heart disease (CHD). Methods Twenty-five fetuses with CHD (mean gestational age: 35 ± 1 weeks) underwent fetal cardiac MRI at 3T. Cine imaging was acquired using a balanced steady-state free precession (bSSFP) sequence with Doppler ultrasound gating. Images were reconstructed using both compressed sensing (bSSFP CS) and a pre-trained convolutional neural network trained for DL denoising (bSSFP DL). Images were compared qualitatively based on a 5-point Likert scale (from 1 = non-diagnostic to 5 = excellent) and quantitatively by calculating the apparent signal-to-noise ratio (aSNR) and contrast-to-noise ratio (aCNR). Diagnostic confidence was assessed for the atria, ventricles, foramen ovale, valves, great vessels, aortic arch, and pulmonary veins. Results Fetal cardiac cine MRI was successful in 23 fetuses (92%), with two studies excluded due to extensive fetal motion. The image quality of bSSFP DL cine reconstructions was rated superior to standard bSSFP CS cine images in terms of contrast [3 (interquartile range: 2-4) vs. 5 (4-5), P < 0.001] and endocardial edge definition [3 (2-4) vs. 4 (4-5), P < 0.001], while the extent of artifacts was found to be comparable [4 (3-4.75) vs. 4 (3-4), P = 0.40]. bSSFP DL images had higher aSNR and aCNR compared with the bSSFP CS images (aSNR: 13.4 ± 6.9 vs. 8.3 ± 3.6, P < 0.001; aCNR: 26.6 ± 15.8 vs. 14.4 ± 6.8, P < 0.001). Diagnostic confidence of the bSSFP DL images was superior for the evaluation of cardiovascular structures (e.g., atria and ventricles: P = 0.003). Conclusion DL image denoising provides superior quality for DUS-gated fetal cardiac cine imaging of CHD compared to standard CS image reconstruction.
Collapse
Affiliation(s)
- Thomas M Vollbrecht
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany
- Quantitative Imaging Lab Bonn (QILaB), Bonn, Germany
| | - Christopher Hart
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany
- Quantitative Imaging Lab Bonn (QILaB), Bonn, Germany
- Department of Pediatric Cardiology, University Hospital Bonn, Bonn, Germany
| | - Shuo Zhang
- Philips GmbH Market DACH, PD Clinical Science, Hamburg, Germany
| | | | - Alois M Sprinkart
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany
- Quantitative Imaging Lab Bonn (QILaB), Bonn, Germany
| | - Alexander Isaak
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany
- Quantitative Imaging Lab Bonn (QILaB), Bonn, Germany
| | - Ulrike Attenberger
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany
| | - Claus C Pieper
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany
| | - Daniel Kuetting
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany
- Quantitative Imaging Lab Bonn (QILaB), Bonn, Germany
| | - Annegret Geipel
- Department of Obstetrics and Prenatal Medicine, University Hospital Bonn, Bonn, Germany
| | - Brigitte Strizek
- Department of Obstetrics and Prenatal Medicine, University Hospital Bonn, Bonn, Germany
| | - Julian A Luetkens
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany
- Quantitative Imaging Lab Bonn (QILaB), Bonn, Germany
| |
Collapse
|
6
|
Kocaoglu M, Pednekar A, Fleck RJ, Dillman JR. Cardiothoracic Magnetic Resonance Angiography. Curr Probl Diagn Radiol 2024; 53:154-165. [PMID: 37891088 DOI: 10.1067/j.cpradiol.2023.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Revised: 09/01/2023] [Accepted: 10/18/2023] [Indexed: 10/29/2023]
Abstract
Catheter-based angiography is regarded as the clinical reference imaging technique for vessel imaging; however, it is invasive and is currently used for intervention or physiologic measurements. Contrast enhanced magnetic resonance angiography (MRA) with gadolinium-based contrast agents can be performed as a three-dimensional (3D) MRA or as a time resolved 3D (4D) MRA without physiologic synchronization, in which case cardiac and respiratory motion may blur the edges of the vessels and cardiac chambers. Ferumoxytol has recently been a popular contrast agent for MRA in patients with chronic renal failure. Noncontrast 3D MRA with ECG gating and respiratory navigation are safe and accurate noninvasive cross-sectional imaging techniques for the visualization of great vessels of the heart and coronary arteries in a variety of cardiovascular disorders including complex congenital heart diseases. Noncontrast flow dependent MRA techniques such as time of flight, phase contrast, and black-blood MRA techniques can be used as complementary or primary techniques. Here we review both conventional and relatively new contrast enhanced and non-contrast enhanced MRA techniques including ferumoxytol enhanced MRA, and bright-blood and water-fat separation based noncontrast 3D MRA techniques.
Collapse
Affiliation(s)
- Murat Kocaoglu
- Department of Radiology, Cincinnati Children's Hospital Medical Center, MLC1 5031, 3333 Burnet Ave, Cincinnati, OH 45229, USA; Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA.
| | - Amol Pednekar
- Department of Radiology, Cincinnati Children's Hospital Medical Center, MLC1 5031, 3333 Burnet Ave, Cincinnati, OH 45229, USA; Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Robert J Fleck
- Department of Radiology, Cincinnati Children's Hospital Medical Center, MLC1 5031, 3333 Burnet Ave, Cincinnati, OH 45229, USA; Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Jonathan R Dillman
- Department of Radiology, Cincinnati Children's Hospital Medical Center, MLC1 5031, 3333 Burnet Ave, Cincinnati, OH 45229, USA; Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| |
Collapse
|
7
|
Leo I, Sabatino J, Avesani M, Moscatelli S, Bianco F, Borrelli N, De Sarro R, Leonardi B, Calcaterra G, Surkova E, Di Salvo G. Non-Invasive Imaging Assessment in Patients with Aortic Coarctation: A Contemporary Review. J Clin Med 2023; 13:28. [PMID: 38202035 PMCID: PMC10779918 DOI: 10.3390/jcm13010028] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Revised: 12/08/2023] [Accepted: 12/12/2023] [Indexed: 01/12/2024] Open
Abstract
Coarctation of the aorta (CoA) is a congenital abnormality characterized by a narrowing of the aortic lumen, which can lead to significant morbidity and mortality if left untreated. Even after repair and despite significant advances in therapeutic management, these patients have overall reduced long-term survival due to the consequences of chronic afterload increase. Cardiovascular imaging is key from the first diagnosis to serial follow-up. In recent years, novel imaging techniques have emerged, increasing accessibility to advanced imaging modalities and enabling early and non-invasive identification of complications after repair. The aim of this paper is to provide a comprehensive review of the role of different imaging techniques in the evaluation and management of patients with native or repaired CoA, highlighting their unique strengths and limitations.
Collapse
Affiliation(s)
- Isabella Leo
- Department of Experimental and Clinical Medicine, Magna Graecia University, 88100 Catanzaro, Italy; (I.L.)
- CMR Unit, Royal Brompton and Harefield Hospitals, London SW3 5NP, UK;
| | - Jolanda Sabatino
- Department of Experimental and Clinical Medicine, Magna Graecia University, 88100 Catanzaro, Italy; (I.L.)
- Pediatric Cardiology Unit, Department of Woman’s and Child’s Health, University Hospital of Padova, 35128 Padova, Italy;
| | - Martina Avesani
- Pediatric Cardiology Unit, Department of Woman’s and Child’s Health, University Hospital of Padova, 35128 Padova, Italy;
| | - Sara Moscatelli
- Centre for Inherited Cardiovascular Disease, Great Ormond Street Hospital, London WC1N 3JH, UK;
- Institute of Cardiovascular Sciences, University College London, London WC1E 6BT, UK
| | - Francesco Bianco
- Cardiovascular Sciences Department, AOU “Ospedali Riuniti”, 60126 Ancona, Italy;
| | - Nunzia Borrelli
- Adult Congenital Heart Disease Unit, AO dei Colli, Monaldi Hospital, 80131 Naples, Italy
| | - Rosalba De Sarro
- Department of Experimental and Clinical Medicine, University of Messina, 98166 Messina, Italy;
| | - Benedetta Leonardi
- Department of Pediatric Cardiology, Cardiac Surgery and Heart Lung Transplantation, Bambino Gesù Children’s Hospital, IRCCS, 00165 Rome, Italy;
| | | | - Elena Surkova
- CMR Unit, Royal Brompton and Harefield Hospitals, London SW3 5NP, UK;
| | - Giovanni Di Salvo
- Pediatric Cardiology Unit, Department of Woman’s and Child’s Health, University Hospital of Padova, 35128 Padova, Italy;
- Paediatric Research Institute (IRP), Città Della Speranza, 35127 Padua, Italy
| | | |
Collapse
|
8
|
Moscatelli S, Leo I, Bianco F, Surkova E, Pezel T, Donald NA, Triumbari EKA, Bassareo PP, Pradhan A, Cimini A, Perrone MA. The Role of Multimodality Imaging in Patients with Congenital Heart Disease and Infective Endocarditis. Diagnostics (Basel) 2023; 13:3638. [PMID: 38132222 PMCID: PMC10742664 DOI: 10.3390/diagnostics13243638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2023] [Revised: 12/02/2023] [Accepted: 12/09/2023] [Indexed: 12/23/2023] Open
Abstract
Infective endocarditis (IE) represents an important medical challenge, particularly in patients with congenital heart diseases (CHD). Its early and accurate diagnosis is crucial for effective management to improve patient outcomes. Multimodality imaging is emerging as a powerful tool in the diagnosis and management of IE in CHD patients, offering a comprehensive and integrated approach that enhances diagnostic accuracy and guides therapeutic strategies. This review illustrates the utilities of each single multimodality imaging, including transthoracic and transoesophageal echocardiography, cardiac computed tomography (CCT), cardiovascular magnetic resonance imaging (CMR), and nuclear imaging modalities, in the diagnosis of IE in CHD patients. These imaging techniques provide crucial information about valvular and intracardiac structures, vegetation size and location, abscess formation, and associated complications, helping clinicians make timely and informed decisions. However, each one does have limitations that influence its applicability.
Collapse
Affiliation(s)
- Sara Moscatelli
- Inherited Cardiovascular Diseases, Great Ormond Street Hospital, Children NHS Foundation Trust, London WC1N 3JH, UK; (S.M.); (N.A.D.)
- Institute of Cardiovascular Sciences, University College London, London WC1E 6BT, UK
| | - Isabella Leo
- Department of Experimental and Clinical Medicine, Magna Graecia University, 88100 Catanzaro, Italy;
- CMR Unit, Cardiology Department, Royal Brompton and Harefield Hospitals, Guys’ and St Thomas’ NHS Trust, London SW3 5NP, UK
| | - Francesco Bianco
- Cardiovascular Sciences Department, AOU “Ospedali Riuniti”, 60126 Ancona, Italy;
| | - Elena Surkova
- Department of Echocardiography, Royal Brompton and Harefield Hospitals, Guy’s and St Thomas’ NHS Foundation Trust, London SW3 5NP, UK;
| | - Théo Pezel
- Département de Cardiologie, Université Paris-Cité, Hôpital Universitaire de Lariboisière, Assistance Publique des Hôpitaux de Paris (APHP), Inserm UMRS 942, 75010 Paris, France;
| | - Natasha Alexandra Donald
- Inherited Cardiovascular Diseases, Great Ormond Street Hospital, Children NHS Foundation Trust, London WC1N 3JH, UK; (S.M.); (N.A.D.)
| | | | - Pier Paolo Bassareo
- School of Medicine, University College of Dublin, Mater Misericordiae University Hospital, Children’s Health Ireland Crumlin, D07 R2WY Dublin, Ireland;
| | - Akshyaya Pradhan
- Department of Cardiology, King George’s Medical University, Lucknow 226003, India;
| | - Andrea Cimini
- Nuclear Medicine Unit, St. Salvatore Hospital, 67100 L’Aquila, Italy
| | - Marco Alfonso Perrone
- Division of Cardiology and CardioLab, Department of Clinical Sciences and Translational Medicine, University of Rome Tor Vergata, 00133 Rome, Italy
- Clinical Pathways and Epidemiology Unit, Bambino Gesù Children’s Hospital IRCCS, 00165 Rome, Italy
| |
Collapse
|
9
|
Moscatelli S, Gatehouse P, Krupickova S, Mohiaddin R, Voges I, Giese D, Nielles-Vallespin S, Pennell DJ. Impact of compressed sensing (CS) acceleration of two-dimensional (2D) flow sequences in clinical paediatric cardiovascular magnetic resonance (CMR). MAGMA (NEW YORK, N.Y.) 2023; 36:869-876. [PMID: 37202654 PMCID: PMC10667407 DOI: 10.1007/s10334-023-01098-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Revised: 05/02/2023] [Accepted: 05/03/2023] [Indexed: 05/20/2023]
Abstract
OBJECTIVES Two-dimensional (2D) through-plane phase-contrast (PC) cine flow imaging assesses shunts and valve regurgitations in paediatric CMR and is considered the reference standard for Clinical quantification of blood Flow (COF). However, longer breath-holds (BH) can reduce compliance with possibly large respiratory manoeuvres altering flow. We hypothesize that reduced BH time by application of CS (Short BH quantification of Flow) (SBOF) retains accuracy while enabling faster, potentially more reliable flows. We investigate the variance between COF and SBOF cine flows. METHODS Main pulmonary artery (MPA) and sinotubular junction (STJ) planes were acquired at 1.5 T in paediatric patients by COF and SBOF. RESULTS 21 patients (mean age 13.9, 10-17y) were enrolled. The BH times were COF mean 11.7 s (range 8.4-20.9 s) vs SBOF mean 6.5 s (min 3.6-9.1 s). The differences and 95% CI between the COF and SBOF flows were LVSV -1.43 ± 13.6(ml/beat), LVCO 0.16 ± 1.35(l/min) and RVSV 2.95 ± 12.3(ml/beat), RVCO 0.27 ± 0.96(l/min), QP/QS were SV 0.04 ± 0.19, CO 0.02 ± 0.23. Variability between COF and SBOF did not exceed intrasession variation of COF. CONCLUSION SBOF reduces breath-hold duration to 56% of COF. RV flow by SBOF was biased compared to COF. The variation (95% CI) between COF and SBOF was similar to the COF intrasession test-retest 95% CI.
Collapse
Affiliation(s)
- Sara Moscatelli
- Department of Paediatric Cardiology, Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- Department of CMR, Royal Brompton Hospital, Part of Guy's and St Thomas' NHS Foundation Trust, Sydney Street, London, SW3 6NP, UK
| | - Peter Gatehouse
- Department of CMR, Royal Brompton Hospital, Part of Guy's and St Thomas' NHS Foundation Trust, Sydney Street, London, SW3 6NP, UK.
- National Heart and Lung Institute, Imperial College, London, England.
| | - Sylvia Krupickova
- Department of Paediatric Cardiology, Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
- Department of CMR, Royal Brompton Hospital, Part of Guy's and St Thomas' NHS Foundation Trust, Sydney Street, London, SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, London, England
| | - Raad Mohiaddin
- Department of CMR, Royal Brompton Hospital, Part of Guy's and St Thomas' NHS Foundation Trust, Sydney Street, London, SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, London, England
| | - Inga Voges
- Department of Congenital Heart Disease and Pediatric Cardiology, University Hospital Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Daniel Giese
- Magnetic Resonance, Siemens Healthcare GmbH, Erlangen, Germany
| | - Sonia Nielles-Vallespin
- Department of CMR, Royal Brompton Hospital, Part of Guy's and St Thomas' NHS Foundation Trust, Sydney Street, London, SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, London, England
| | - Dudley J Pennell
- Department of CMR, Royal Brompton Hospital, Part of Guy's and St Thomas' NHS Foundation Trust, Sydney Street, London, SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, London, England
| |
Collapse
|
10
|
Moscatelli S, Pergola V, Motta R, Fortuni F, Borrelli N, Sabatino J, Leo I, Avesani M, Montanaro C, Surkova E, Mapelli M, Perrone MA, di Salvo G. Multimodality Imaging Assessment of Tetralogy of Fallot: From Diagnosis to Long-Term Follow-Up. CHILDREN (BASEL, SWITZERLAND) 2023; 10:1747. [PMID: 38002838 PMCID: PMC10670209 DOI: 10.3390/children10111747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 10/21/2023] [Accepted: 10/24/2023] [Indexed: 11/26/2023]
Abstract
Tetralogy of Fallot (TOF) is the most common complex congenital heart disease with long-term survivors, demanding serial monitoring of the possible complications that can be encountered from the diagnosis to long-term follow-up. Cardiovascular imaging is key in the diagnosis and serial assessment of TOF patients, guiding patients' management and providing prognostic information. Thorough knowledge of the pathophysiology and expected sequalae in TOF, as well as the advantages and limitations of different non-invasive imaging modalities that can be used for diagnosis and follow-up, is the key to ensuring optimal management of patients with TOF. The aim of this manuscript is to provide a comprehensive overview of the role of each modality and common protocols used in clinical practice in the assessment of TOF patients.
Collapse
Affiliation(s)
- Sara Moscatelli
- Centre for Inherited Cardiovascular Diseases, Great Ormond Street Hospital, London WC1N 3JH, UK
- Institute of Cardiovascular Sciences, University College London, London WC1E 6BT, UK
- Paediatric Cardiology Department, Royal Brompton and Harefield Hospitals, Guy's and St. Thomas' NHS Foundation Trust, London SW3 5NP, UK
| | - Valeria Pergola
- Dipartimento di Scienze Cardio-Toraco-Vascolari e Sanità pubblica, University Hospital of Padua, 35128 Padua, Italy
| | - Raffaella Motta
- Dipartimento di Scienze Cardio-Toraco-Vascolari e Sanità pubblica, University Hospital of Padua, 35128 Padua, Italy
| | - Federico Fortuni
- Department of Cardiology, San Giovanni Battista Hospital, 06034 Foligno, Italy
- Department of Cardiology, Leiden University Medical Center, 2300 Leiden, The Netherlands
| | - Nunzia Borrelli
- Adult Congenital Heart Disease Unit, A.O. dei Colli, Monaldi Hospital, 80131 Naples, Italy
| | - Jolanda Sabatino
- Experimental and Clinical Medicine Department, University Magna Graecia of Catanzaro, 88100 Catanzaro, Italy
| | - Isabella Leo
- Experimental and Clinical Medicine Department, University Magna Graecia of Catanzaro, 88100 Catanzaro, Italy
| | - Martina Avesani
- Division of Paediatric Cardiology, Department of Women and Children's Health, University Hospital of Padua, 35128 Padua, Italy
| | - Claudia Montanaro
- Adult Congenital Heart Centre and National Centre for Pulmonary Hypertension, Royal Brompton Hospital, Guy's and St. Thomas's NHS Foundation Trust, London SW3 5NP, UK
- CMR Unit, Cardiology Department, Royal Brompton and Harefield Hospitals, Guy's and St. Thomas' NHS Foundation Trust, London SW3 5NP, UK
- National Heart and Lung Institute, Imperial College London, London SW3 6LY, UK
| | - Elena Surkova
- Department of Echocardiography, Royal Brompton and Harefield Hospitals, Guy's and St. Thomas' NHS Foundation Trust, London SW3 5NP, UK
| | - Massimo Mapelli
- Centro Cardiologico Monzino, IRCCS, 20138 Milan, Italy
- Department of Clinical Sciences and Community Health, Cardiovascular Section, University of Milan, 20122 Milan, Italy
| | - Marco Alfonso Perrone
- Clinical Pathways and Epidemiology Unit, Bambino Gesù Children's Hospital IRCCS, 00165 Rome, Italy
- Division of Cardiology and Cardio Lab, Department of Clinical Science and Translational Medicine, University of Rome Tor Vergata, 00133 Rome, Italy
| | - Giovanni di Salvo
- Division of Paediatric Cardiology, Department of Women and Children's Health, University Hospital of Padua, 35128 Padua, Italy
| |
Collapse
|
11
|
Pednekar A, Kocaoglu M, Wang H, Tanimoto A, Tkach JA, Lang S, Taylor MD. Accelerated Cine Cardiac MRI Using Deep Learning-Based Reconstruction: A Systematic Evaluation. J Magn Reson Imaging 2023. [PMID: 37855257 DOI: 10.1002/jmri.29081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 10/05/2023] [Accepted: 10/05/2023] [Indexed: 10/20/2023] Open
Abstract
BACKGROUND Breath-holding (BH) for cine balanced steady state free precession (bSSFP) imaging is challenging for patients with impaired BH capacity. Deep learning-based reconstruction (DLR) of undersampled k-space promises to shorten BHs while preserving image quality and accuracy of ventricular assessment. PURPOSE To perform a systematic evaluation of DLR of cine bSSFP images from undersampled k-space over a range of acceleration factors. STUDY TYPE Retrospective. SUBJECTS Fifteen pectus excavatum patients (mean age 16.8 ± 5.4 years, 20% female) with normal cardiac anatomy and function and 12-second BH capability. FIELD STRENGTH/SEQUENCE 1.5-T, cine bSSFP. ASSESSMENT Retrospective DLR was conducted by applying compressed sensitivity encoding (C-SENSE) acceleration to systematically undersample fully sampled k-space cine bSSFP acquisition data over an acceleration/undersampling factor (R) considering a range of 2 to 8. Quality imperceptibility (QI) measures, including structural similarity index measure, were calculated using images reconstructed from fully sampled k-space as a reference. Image quality, including contrast and edge definition, was evaluated for diagnostic adequacy by three readers with varying levels of experience in cardiac MRI (>4 years, >18 years, and 1 year). Automated DL-based biventricular segmentation was performed commercially available software by cardiac radiologists with more than 4 years of experience. STATISTICAL TESTS Tukey box plots, linear mixed effects model, analysis of variance (ANOVA), weighted kappa, Kruskal-Wallis test, and Wilcoxon signed-rank test were employed as appropriate. A P-value <0.05 was considered statistically significant. RESULTS There was a significant decrease in the QI values and edge definition scores as R increased. Diagnostically adequate image quality was observed up to R = 5. The effect of R on all biventricular volumetric indices was non-significant (P = 0.447). DATA CONCLUSION The biventricular volumetric indices obtained from the reconstruction of fully sampled cine bSSFP acquisitions and DLR of the same k-space data undersampled by C-SENSE up to R = 5 may be comparable. EVIDENCE LEVEL 3 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Amol Pednekar
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA
| | - Murat Kocaoglu
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA
| | - Hui Wang
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA
- MR Clinical Science, Philips Healthcare, Cincinnati, Ohio, USA
| | - Aki Tanimoto
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA
| | - Jean A Tkach
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA
| | - Sean Lang
- The Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA
| | - Michael D Taylor
- The Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA
| |
Collapse
|
12
|
van der Ven JPG, van Genuchten W, Sadighy Z, Valsangiacomo Buechel ER, Sarikouch S, Boersma E, Helbing WA. Multivendor Evaluation of Automated MRI Postprocessing of Biventricular Size and Function for Children With and Without Congenital Heart Defects. J Magn Reson Imaging 2023; 58:794-804. [PMID: 36573004 DOI: 10.1002/jmri.28568] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 12/05/2022] [Accepted: 12/05/2022] [Indexed: 08/08/2023] Open
Abstract
BACKGROUND Manually segmenting cardiac structures is time-consuming and produces variability in MRI assessments. Automated segmentation could solve this. However, current software is developed for adults without congenital heart defects (CHD). PURPOSE To evaluate automated segmentation of left ventricle (LV) and right ventricle (RV) for pediatric MRI studies. STUDY TYPE Retrospective comparative study. POPULATION Twenty children per group of: healthy children, LV-CHD, tetralogy of Fallot (ToF), and univentricular CHD, aged 11.7 [8.9-16.0], 14.2 [10.6-15.7], 14.6 [11.6-16.4], and 12.2 [10.2-14.9] years, respectively. SEQUENCE/FIELD STRENGTH Balanced steady-state free precession at 1.5 T. ASSESSMENT Biventricular volumes and masses were calculated from a short-axis stack of images, which were segmented manually and using two fully automated software suites (Medis Suite 3.2, Medis, Leiden, the Netherlands and SuiteHeart 5.0, Neosoft LLC, Pewaukee, USA). Fully automated segmentations were manually adjusted to provide two further sets of segmentations. Fully automated and adjusted automated segmentation were compared to manual segmentation. Segmentation times and reproducibility for each method were assessed. STATISTICAL TESTS Bland Altman analysis and intraclass correlation coefficients (ICC) were used to compare volumes and masses between methods. Postprocessing times were compared by paired t-tests. RESULTS Fully automated methods provided good segmentation (ICC > 0.90 compared to manual segmentation) for the LV in the healthy and left-sided CHD groups (eg LV-EDV difference for healthy children 1.4 ± 11.5 mL, ICC: 0.97, for Medis and 3.0 ± 12.2 mL, ICC: 0.96 for SuiteHeart). Both automated methods gave larger errors (ICC: 0.62-0.94) for the RV in these populations, and for all structures in the ToF and univentricular CHD groups. Adjusted automated segmentation agreed well with manual segmentation (ICC: 0.71-1.00), improved reproducibility and reduced segmentation time in all patient groups, compared to manual segmentation. DATA CONCLUSION Fully automated segmentation eliminates observer variability but may produce large errors compared to manual segmentation. Manual adjustments reduce these errors, improve reproducibility, and reduce postprocessing times compared to manual segmentation. Adjusted automated segmentation is reasonable in children with and without CHD. EVIDENCE LEVEL 3. TECHNICAL EFFICACY Stage 2.
Collapse
Affiliation(s)
- Jelle P G van der Ven
- Department of Pediatrics, Division of Cardiology, Erasmus University Medical Center-Sophia Children's Hospital, Rotterdam, the Netherlands
- Netherlands Heart Institute, Utrecht, the Netherlands
| | - Wouter van Genuchten
- Department of Pediatrics, Division of Cardiology, Erasmus University Medical Center-Sophia Children's Hospital, Rotterdam, the Netherlands
- Netherlands Heart Institute, Utrecht, the Netherlands
| | - Zaheda Sadighy
- Department of Pediatrics, Division of Cardiology, Erasmus University Medical Center-Sophia Children's Hospital, Rotterdam, the Netherlands
| | | | - Samir Sarikouch
- Department of Heart, Thoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Eric Boersma
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Willem A Helbing
- Department of Pediatrics, Division of Cardiology, Erasmus University Medical Center-Sophia Children's Hospital, Rotterdam, the Netherlands
- Department of Radiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| |
Collapse
|
13
|
Moscatelli S, Leo I, Bianco F, Borrelli N, Beltrami M, Garofalo M, Milano EG, Bisaccia G, Iellamo F, Bassareo PP, Pradhan A, Cimini A, Perrone MA. The Role of Multimodality Imaging in Pediatric Cardiomyopathies. J Clin Med 2023; 12:4866. [PMID: 37510983 PMCID: PMC10381492 DOI: 10.3390/jcm12144866] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 07/17/2023] [Accepted: 07/18/2023] [Indexed: 07/30/2023] Open
Abstract
Cardiomyopathies are a heterogeneous group of myocardial diseases representing the first cause of heart transplantation in children. Diagnosing and classifying the different phenotypes can be challenging, particularly in this age group, where cardiomyopathies are often overlooked until the onset of severe symptoms. Cardiovascular imaging is crucial in the diagnostic pathway, from screening to classification and follow-up assessment. Several imaging modalities have been proven to be helpful in this field, with echocardiography undoubtedly representing the first imaging approach due to its low cost, lack of radiation, and wide availability. However, particularly in this clinical context, echocardiography may not be able to differentiate from cardiomyopathies with similar phenotypes and is often complemented with cardiovascular magnetic resonance. The latter allows a radiation-free differentiation between different phenotypes with unique myocardial tissue characterization, thus identifying the presence and extent of myocardial fibrosis. Nuclear imaging and computed tomography have a complementary role, although they are less used in daily clinical practice due to the concern related to the use of radiation in pediatric patients. However, these modalities may have some advantages in evaluating children with cardiomyopathies. This paper aims to review the strengths and limitations of each imaging modality in evaluating pediatric patients with suspected or known cardiomyopathies.
Collapse
Affiliation(s)
- Sara Moscatelli
- Inherited Cardiovascular Diseases, Great Ormond Street Hospital for Children NHS Foundation Trust, London WC1N 3JH, UK
- Paediatric Cardiology Department, Royal Brompton and Harefield Hospitals, Guy's and St. Thomas' NHS Foundation Trust, London SW3 5NP, UK
| | - Isabella Leo
- Department of Experimental and Clinical Medicine, Magna Graecia University, 88100 Catanzaro, Italy
- Cardiology Department, CMR Unit, Royal Brompton and Harefield Hospitals, Guys' and St. Thomas' NHS Trust, London SW3 5NP, UK
| | - Francesco Bianco
- Cardiovascular Sciences Department-AOU "Ospedali Riuniti", 60126 Ancona, Italy
| | - Nunzia Borrelli
- Adult Congenital Heart Disease Unit, A.O. dei Colli, Monaldi Hospital, 80131 Naples, Italy
| | | | - Manuel Garofalo
- Department of Clinical and Experimental Medicine, Careggi University Hospital, 50134 Florence, Italy
| | - Elena Giulia Milano
- Centre for Cardiovascular Imaging, Great Ormond Street Hospital for Children NHS Foundation Trust, London WC1N 3JH, UK
| | - Giandomenico Bisaccia
- Department of Neuroscience, Imaging and Clinical Sciences, "G.d'Annunzio" University of Chieti-Pescara, 66100 Chieti, Italy
| | - Ferdinando Iellamo
- Division of Cardiology and Cardio Lab, Department of Clinical Sciences and Translational Medicine, University of Rome Tor Vergata, 00133 Rome, Italy
| | - Pier Paolo Bassareo
- School of Medicine, University College of Dublin, Mater Misericordiae University Hospital and Children's Health Ireland Crumlin, D07 R2WY Dublin, Ireland
| | - Akshyaya Pradhan
- Department of Cardiology, King George's Medical University, Lucknow 226003, India
| | - Andrea Cimini
- Nuclear Medicine Unit, St. Salvatore Hospital, 67100 L'Aquila, Italy
| | - Marco Alfonso Perrone
- Division of Cardiology and Cardio Lab, Department of Clinical Sciences and Translational Medicine, University of Rome Tor Vergata, 00133 Rome, Italy
- Clinical Pathways and Epidemiology Unit, Bambino Gesù Children's Hospital IRCCS, 00165 Rome, Italy
| |
Collapse
|
14
|
Yang Y, Shah Z, Jacob AJ, Hair J, Chitiboi T, Passerini T, Yerly J, Di Sopra L, Piccini D, Hosseini Z, Sharma P, Sahu A, Stuber M, Oshinski JN. Deep learning-based left ventricular segmentation demonstrates improved performance on respiratory motion-resolved whole-heart reconstructions. FRONTIERS IN RADIOLOGY 2023; 3:1144004. [PMID: 37492382 PMCID: PMC10365088 DOI: 10.3389/fradi.2023.1144004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Accepted: 05/17/2023] [Indexed: 07/27/2023]
Abstract
Introduction Deep learning (DL)-based segmentation has gained popularity for routine cardiac magnetic resonance (CMR) image analysis and in particular, delineation of left ventricular (LV) borders for LV volume determination. Free-breathing, self-navigated, whole-heart CMR exams provide high-resolution, isotropic coverage of the heart for assessment of cardiac anatomy including LV volume. The combination of whole-heart free-breathing CMR and DL-based LV segmentation has the potential to streamline the acquisition and analysis of clinical CMR exams. The purpose of this study was to compare the performance of a DL-based automatic LV segmentation network trained primarily on computed tomography (CT) images in two whole-heart CMR reconstruction methods: (1) an in-line respiratory motion-corrected (Mcorr) reconstruction and (2) an off-line, compressed sensing-based, multi-volume respiratory motion-resolved (Mres) reconstruction. Given that Mres images were shown to have greater image quality in previous studies than Mcorr images, we hypothesized that the LV volumes segmented from Mres images are closer to the manual expert-traced left ventricular endocardial border than the Mcorr images. Method This retrospective study used 15 patients who underwent clinically indicated 1.5 T CMR exams with a prototype ECG-gated 3D radial phyllotaxis balanced steady state free precession (bSSFP) sequence. For each reconstruction method, the absolute volume difference (AVD) of the automatically and manually segmented LV volumes was used as the primary quantity to investigate whether 3D DL-based LV segmentation generalized better on Mcorr or Mres 3D whole-heart images. Additionally, we assessed the 3D Dice similarity coefficient between the manual and automatic LV masks of each reconstructed 3D whole-heart image and the sharpness of the LV myocardium-blood pool interface. A two-tail paired Student's t-test (alpha = 0.05) was used to test the significance in this study. Results & Discussion The AVD in the respiratory Mres reconstruction was lower than the AVD in the respiratory Mcorr reconstruction: 7.73 ± 6.54 ml vs. 20.0 ± 22.4 ml, respectively (n = 15, p-value = 0.03). The 3D Dice coefficient between the DL-segmented masks and the manually segmented masks was higher for Mres images than for Mcorr images: 0.90 ± 0.02 vs. 0.87 ± 0.03 respectively, with a p-value = 0.02. Sharpness on Mres images was higher than on Mcorr images: 0.15 ± 0.05 vs. 0.12 ± 0.04, respectively, with a p-value of 0.014 (n = 15). Conclusion We conclude that the DL-based 3D automatic LV segmentation network trained on CT images and fine-tuned on MR images generalized better on Mres images than on Mcorr images for quantifying LV volumes.
Collapse
Affiliation(s)
- Yitong Yang
- Wallace H. Coulter Department of Biomedical Engineering, Emory University and the Georgia Institute of Technology, Atlanta, GA, United States
| | - Zahraw Shah
- Wallace H. Coulter Department of Biomedical Engineering, Emory University and the Georgia Institute of Technology, Atlanta, GA, United States
| | - Athira J. Jacob
- Digital Technology and Innovation, Siemens Medical Solutions USA, Princeton, NJ, United States
| | - Jackson Hair
- Wallace H. Coulter Department of Biomedical Engineering, Emory University and the Georgia Institute of Technology, Atlanta, GA, United States
| | - Teodora Chitiboi
- Digital Technology and Innovation, Siemens Medical Solutions USA, Princeton, NJ, United States
| | - Tiziano Passerini
- Digital Technology and Innovation, Siemens Medical Solutions USA, Princeton, NJ, United States
| | - Jerome Yerly
- Diagnostic and Interventional Radiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Lorenzo Di Sopra
- Diagnostic and Interventional Radiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Davide Piccini
- Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland
| | - Zahra Hosseini
- MR R&D Collaboration, Siemens Medical Solutions USA, Atlanta, GA, United States
| | - Puneet Sharma
- Digital Technology and Innovation, Siemens Medical Solutions USA, Princeton, NJ, United States
| | - Anurag Sahu
- MR R&D Collaboration, Siemens Medical Solutions USA, Atlanta, GA, United States
| | - Matthias Stuber
- Diagnostic and Interventional Radiology, Lausanne University Hospital, Lausanne, Switzerland
| | - John N. Oshinski
- Wallace H. Coulter Department of Biomedical Engineering, Emory University and the Georgia Institute of Technology, Atlanta, GA, United States
- Department of Radiology & Imaging Science, Emory University School of Medicine, Atlanta, GA, United States
| |
Collapse
|
15
|
Jhaveri S, Battersby E, Stern KWD, Cohen J, Yang Y, Price A, Hughes E, Poston L, Pasupathy D, Taylor P, Vieira MC, Groves A. Normative ranges of biventricular volumes and function in healthy term newborns. J Cardiovasc Magn Reson 2023; 25:26. [PMID: 37095534 PMCID: PMC10127416 DOI: 10.1186/s12968-023-00932-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Accepted: 03/13/2023] [Indexed: 04/26/2023] Open
Abstract
BACKGROUND Cardiovascular magnetic resonance (CMR) is increasingly used in newborns with congenital heart disease. However, reporting on ventricular volumes and mass is hindered by an absence of normative data in this population. DESIGN/METHODS Healthy term (37-41 weeks gestation) newborns underwent non-sedated, free-breathing CMR within the first week of life using the 'feed and wrap' technique. End-diastolic volume (EDV), end-systolic volume (ESV) stroke volume (SV) and ejection fraction (EF) were calculated for both left ventricle (LV) and right ventricle (RV). Papillary muscles were separately contoured and included in the myocardial volume. Myocardial mass was calculated by multiplying myocardial volume by 1.05 g/ml. All data were indexed to weight and body surface area (BSA). Inter-observer variability (IOV) was performed on data from 10 randomly chosen infants. RESULTS Twenty healthy newborns (65% male) with a mean (SD) birth weight of 3.54 (0.46) kg and BSA of 0.23 (0.02) m2 were included. Normative LV parameters were indexed EDV 39.0 (4.1) ml/m2, ESV 14.5 (2.5) ml/m2 and ejection fraction (EF) 63.2 (3.4)%. Normative RV indexed EDV, ESV and EF were 47.4 (4.5) ml/m2, 22.6 (2.9) ml/m2 and 52.5 (3.3)% respectively. Mean LV and RV indexed mass were 26.4 (2.8) g/m2 and 12.5 (2.0) g/m2, respectively. There was no difference in ventricular volumes by gender. IOV was excellent with an intra-class coefficient > 0.95 except for RV mass (0.94). CONCLUSION This study provides normative data on LV and RV parameters in healthy newborns, providing a novel resource for comparison with newborns with structural and functional heart disease.
Collapse
Affiliation(s)
- Simone Jhaveri
- Department of Pediatric Cardiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
- Zucker School of Medicine at Hofstra/Northwell, Cohen Children's Medical Center of New York, New Hyde Park, NY, USA.
| | - Ellie Battersby
- Center for the Developing Brain, Kings College London, London, UK
| | - Kenan W D Stern
- Department of Pediatric Cardiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Jennifer Cohen
- Department of Pediatric Cardiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Yang Yang
- Biomedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Anthony Price
- Center for the Developing Brain, Kings College London, London, UK
| | - Emer Hughes
- Center for the Developing Brain, Kings College London, London, UK
| | - Lucilla Poston
- Department of Women and Children's Health, School of Life Course and Population Sciences, Kings College London, London, UK
| | - Dharmintra Pasupathy
- Department of Women and Children's Health, School of Life Course and Population Sciences, Kings College London, London, UK
- Reproduction and Perinatal Centre, Faculty of Medicine and Health, University of Sydney, Syndey, NSW, Australia
| | - Paul Taylor
- Department of Women and Children's Health, School of Life Course and Population Sciences, Kings College London, London, UK
| | - Matias C Vieira
- Department of Women and Children's Health, School of Life Course and Population Sciences, Kings College London, London, UK
| | - Alan Groves
- Department of Pediatrics, Dell Medical School at the University of Austin, Austin, TX, USA
| |
Collapse
|
16
|
Moscatelli S, Leo I, Lisignoli V, Boyle S, Bucciarelli-Ducci C, Secinaro A, Montanaro C. Cardiovascular Magnetic Resonance from Fetal to Adult Life-Indications and Challenges: A State-of-the-Art Review. CHILDREN (BASEL, SWITZERLAND) 2023; 10:children10050763. [PMID: 37238311 DOI: 10.3390/children10050763] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 04/19/2023] [Accepted: 04/21/2023] [Indexed: 05/28/2023]
Abstract
Cardiovascular magnetic resonance (CMR) imaging offers a comprehensive, non-invasive, and radiation-free imaging modality, which provides a highly accurate and reproducible assessment of cardiac morphology and functions across a wide spectrum of cardiac conditions spanning from fetal to adult life. It minimises risks to the patient, particularly the risks associated with exposure to ionising radiation and the risk of complications from more invasive haemodynamic assessments. CMR utilises high spatial resolution and provides a detailed assessment of intracardiac and extracardiac anatomy, ventricular and valvular function, and flow haemodynamic and tissue characterisation, which aid in the diagnosis, and, hence, with the management of patients with cardiac disease. This article aims to discuss the role of CMR and the indications for its use throughout the different stages of life, from fetal to adult life.
Collapse
Affiliation(s)
- Sara Moscatelli
- Inherited Cardiovascular Diseases, Great Ormond Street, Children NHS Foundation Trust, London WC1N 3JH, UK
- Paediatric Cardiology Department, Royal Brompton and Harefield Hospitals, Guy's and St Thomas' NHS Foundation Trust, London SW3 5NP, UK
| | - Isabella Leo
- Department of Experimental and Clinical Medicine, Magna Graecia University, 88100 Catanzaro, Italy
- CMR Unit, Cardiology Department, Royal Brompton and Harefield Hospitals, Guy's and St Thomas' NHS Foundation Trust, London SW3 5NP, UK
| | - Veronica Lisignoli
- Department of Cardiac Surgery, Cardiology, Heart and Lung Transplantation, Bambino Gesù Children's Hospital IRCCS, 00165 Rome, Italy
- Adult Congenital Heart Disease Department, Royal Brompton and Harefield Hospitals, Guy's and St Thomas' NHS Foundation Trust, London SW3 5NP, UK
| | - Siobhan Boyle
- Adult Congenital Heart Disease Department, Royal Brompton and Harefield Hospitals, Guy's and St Thomas' NHS Foundation Trust, London SW3 5NP, UK
- Cardiology Department, Logan Hospital, Loganlea Rd, Meadowbrook, QLD 4131, Australia
| | - Chiara Bucciarelli-Ducci
- CMR Unit, Cardiology Department, Royal Brompton and Harefield Hospitals, Guy's and St Thomas' NHS Foundation Trust, London SW3 5NP, UK
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College University, London SW7 2BX, UK
| | - Aurelio Secinaro
- Radiology Department, Bambino Gesù Children's Hospital IRCCS, 00165 Rome, Italy
| | - Claudia Montanaro
- CMR Unit, Cardiology Department, Royal Brompton and Harefield Hospitals, Guy's and St Thomas' NHS Foundation Trust, London SW3 5NP, UK
- Adult Congenital Heart Disease Department, Royal Brompton and Harefield Hospitals, Guy's and St Thomas' NHS Foundation Trust, London SW3 5NP, UK
- National Heart and Lung Institute, Imperial Collage London, Dovehouse St, London SW3 6LY, UK
| |
Collapse
|
17
|
Kravchenko D, Isaak A, Zhang S, Katemann C, Mesropyan N, Bischoff LM, Pieper CC, Kuetting D, Attenberger U, Weber O, Hart C, Luetkens JA. Free-breathing pseudo-golden-angle bSSFP cine cardiac MRI for biventricular functional assessment in congenital heart disease. Eur J Radiol 2023; 163:110831. [PMID: 37059004 DOI: 10.1016/j.ejrad.2023.110831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 03/23/2023] [Accepted: 04/07/2023] [Indexed: 04/16/2023]
Abstract
PURPOSE To compare standard breath-hold (BH) cine imaging to a radial pseudo-golden-angle free-breathing (FB) technique in congenital heart disease (CHD). METHODS In this prospective study, short-axis and 4-chamber BH and FB cardiac MRI sequences of 25 participants with CHD acquired at 1.5 Tesla, were quantitatively compared regarding ventricular volumes, function, interventricular septum thickness (IVSD), apparent signal to noise ratio (aSNR), and estimated contrast to noise ratio (eCNR). For qualitative comparison, three image quality criteria (contrast, endocardial edge definition, and artefacts) were rated on a 5-point Likert scale (5: excellent, 1: non-diagnostic). Paired t-Test was used for group comparisons, Bland-Altman analysis for agreement between techniques. Inter-reader agreement was compared using intraclass correlation coefficient. RESULTS IVSD (BH 7.4 ± 2.1 mm vs FB 7.4 ± 1.9 mm, p =.71), biventricular ejection fraction (left ventricle [LV]: 56.4 ± 10.8% vs 56.1 ± 9.3%, p =.83; right ventricle [RV]: 49.5 ± 8.6% vs 49.7 ± 10.1%, p =.83), and biventricular end diastolic volume (LV: 176.3 ± 63.9 ml vs 173.9 ± 64.9 ml, p =.90; RV: 185.4 ± 63.8 ml vs 189.6 ± 66.6 ml, p =.34) were comparable. Mean measurement time for FB short-axis sequences was 8.1 ± 1.3 compared to 4.4 ± 1.3 min for BH (p <.001). Subjective image quality between sequences was deemed comparable, (4.6 ± 0.6 vs 4.5 ± 0.6, p =.26, for 4-chamber views) with a significant difference regarding short-axis views (4.9 ± 0.3 vs 4.5 ± 0.6, p =.008). aSNR was similar (BH 25.8 ± 11.2 vs FB 22.2 ± 9.5, p =.24), while eCNR was higher for BH (89.1 ± 36.1 vs 68.5 ± 32.1, p =.03). CONCLUSION FB sequences yielded comparable results to BH regarding image quality, biventricular volumetry, and function, though measurement times were longer. The FB sequence described might be clinically valuable when BHs are insufficiently performed.
Collapse
Affiliation(s)
- Dmitrij Kravchenko
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany; Quantitative Imaging Lab Bonn (QILaB), Germany
| | - Alexander Isaak
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany; Quantitative Imaging Lab Bonn (QILaB), Germany
| | - Shuo Zhang
- Philips GmbH Market DACH, Hamburg, Germany
| | | | - Narine Mesropyan
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany; Quantitative Imaging Lab Bonn (QILaB), Germany
| | - Leon M Bischoff
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany; Quantitative Imaging Lab Bonn (QILaB), Germany
| | - Claus C Pieper
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany
| | - Daniel Kuetting
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany; Quantitative Imaging Lab Bonn (QILaB), Germany
| | - Ulrike Attenberger
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany
| | | | - Christopher Hart
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany; Department of Pediatric Cardiology, University Hospital Bonn, Bonn, Germany
| | - Julian A Luetkens
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany; Quantitative Imaging Lab Bonn (QILaB), Germany.
| |
Collapse
|
18
|
Pickard SS, Armstrong AK, Balasubramanian S, Buddhe S, Crum K, Kong G, Lang SM, Lee MV, Lopez L, Natarajan SS, Norris MD, Parra DA, Parthiban A, Powell AJ, Priromprintr B, Rogers LS, Sachdeva S, Shah SS, Smith CA, Stern KWD, Xiang Y, Young LT, Sachdeva R. Appropriateness of cardiovascular computed tomography and magnetic resonance imaging in patients with conotruncal defects. J Cardiovasc Comput Tomogr 2023:S1934-5925(23)00048-5. [PMID: 36868899 DOI: 10.1016/j.jcct.2023.01.044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 12/11/2022] [Accepted: 01/24/2023] [Indexed: 03/05/2023]
Abstract
BACKGROUND To promote the rational use of cardiovascular imaging in patients with congenital heart disease, the American College of Cardiology developed Appropriate Use Criteria (AUC), but its clinical application and pre-release benchmarks have not been evaluated. We aimed to evaluate the appropriateness of indications for cardiovascular magnetic resonance (CMR) and cardiovascular computed tomography (CCT) in patients with conotruncal defects and to identify factors associated with maybe or rarely appropriate (M/R) indications. METHODS Twelve centers each contributed a median of 147 studies performed prior to AUC publication (01/2020) on patients with conotruncal defects. To incorporate patient characteristics and center-level effects, a hierarchical generalized linear mixed model was used. RESULTS Of the 1753 studies (80% CMR, and 20% CCT), 16% were rated M/R. Center M/R ranged from 4 to 39%. Infants accounted for 8.4% of studies. In multivariable analyses, patient- and study-level factors associated with M/R rating included: age <1 year (OR 1.90 [1.15-3.13]), truncus arteriosus (vs. tetralogy of Fallot, OR 2.55 [1.5-4.35]), and CCT (vs. CMR, OR 2.67 [1.87-3.83]). None of the provider- or center-level factors reached statistical significance in the multivariable model. CONCLUSIONS Most CMRs and CCTs ordered for the follow-up care of patients with conotruncal defects were rated appropriate. However, there was significant center-level variation in appropriateness ratings. Younger age, CCT, and truncus arteriosus were independently associated with higher odds of M/R rating. These findings could inform future quality improvement initiatives and further exploration of factors resulting in center-level variation.
Collapse
Affiliation(s)
- Sarah S Pickard
- Department of Cardiology, Boston Children's Hospital, Department of Pediatrics, Harvard Medical School, Boston, MA, USA
| | | | - Sowmya Balasubramanian
- Department of Pediatrics, University of Michigan, C.S. Mott Children's Hospital, AnnArbor, MI, USA
| | - Sujatha Buddhe
- Department of Cardiology, Seattle Children's Hospital, University of Washington School of Medicine, Seattle, WA, USA
| | - Kimberly Crum
- Department of Pediatrics, Monroe Carell Jr. Children's Hospital at Vanderbilt, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Grace Kong
- Department of Pediatrics, Division of Pediatric Cardiology, Icahn School of Medicine at Mount Sinai, Mount Sinai Kravis Children's Heart Center, New York, NY, USA
| | - Sean M Lang
- The Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Marc V Lee
- Nationwide Children's Hospital, The Heart Center, Columbus, OH, USA
| | - Leo Lopez
- Department of Pediatrics, Divison of Pediatric Cardiology, Lucile Packard Children's Hospital, Stanford University School of Medicine, Palo Alto, CA, USA
| | - Shobha S Natarajan
- Department of Pediatrics, Divison of Pediatric Cardiology, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Mark D Norris
- Department of Pediatrics, University of Michigan, C.S. Mott Children's Hospital, AnnArbor, MI, USA
| | - David A Parra
- Department of Pediatrics, Monroe Carell Jr. Children's Hospital at Vanderbilt, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Anitha Parthiban
- Department of Cardiology, Texas Children's Hospital, Baylor College of Medicine, Houston, TX, USA
| | - Andrew J Powell
- Department of Cardiology, Boston Children's Hospital, Department of Pediatrics, Harvard Medical School, Boston, MA, USA
| | - Bryant Priromprintr
- Department of Pediatrics, Divison of Pediatric Cardiology, Lucile Packard Children's Hospital, Stanford University School of Medicine, Palo Alto, CA, USA
| | - Lindsay S Rogers
- Department of Pediatrics, Divison of Pediatric Cardiology, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Shagun Sachdeva
- Department of Cardiology, Texas Children's Hospital, Baylor College of Medicine, Houston, TX, USA
| | - Sanket S Shah
- Department of Pediatrics, Divison of Pediatric Cardiology, Children's Mercy Kansas City, University of Missouri, Kansas City, MO, USA
| | - Clayton A Smith
- Pediatric Biostatistics Core, Department of Pediatrics, Children's Healthcare of Atlanta, Emory University, Atlanta, GA, USA
| | - Kenan W D Stern
- Department of Pediatrics, Division of Pediatric Cardiology, Icahn School of Medicine at Mount Sinai, Mount Sinai Kravis Children's Heart Center, New York, NY, USA
| | - Yijin Xiang
- Pediatric Biostatistics Core, Department of Pediatrics, Children's Healthcare of Atlanta, Emory University, Atlanta, GA, USA
| | - Luciana T Young
- Department of Cardiology, Seattle Children's Hospital, University of Washington School of Medicine, Seattle, WA, USA
| | - Ritu Sachdeva
- Department of Pediatrics, Division of Pediatric Cardiology, Emory University School of Medicine and Children's Healthcare of Atlanta, Atlanta, GA, USA.
| |
Collapse
|
19
|
Rashid I, Ginami G, Nordio G, Fotaki A, Neji R, Alam H, Pushparajah K, Frigiola A, Valverde I, Botnar RM, Prieto C. Magnetization Transfer BOOST Noncontrast Angiography Improves Pulmonary Vein Imaging in Adults With Congenital Heart Disease. J Magn Reson Imaging 2023; 57:521-531. [PMID: 35642573 PMCID: PMC10084321 DOI: 10.1002/jmri.28280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2022] [Revised: 05/14/2022] [Accepted: 05/17/2022] [Indexed: 01/20/2023] Open
Abstract
BACKGROUND Cardiac MRI plays an important role in the diagnosis and follow-up of patients with congenital heart disease (CHD). Gadolinium-based contrast agents are often needed to overcome flow-related and off-resonance artifacts that can impair the quality of conventional noncontrast 3D imaging. As serial imaging is often required in CHD, the development of robust noncontrast 3D MRI techniques is desirable. PURPOSE To assess the clinical utility of noncontrast enhanced magnetization transfer and inversion recovery prepared 3D free-breathing sequence (MTC-BOOST) compared to conventional 3D whole heart imaging in patients with CHD. STUDY TYPE Prospective, image quality. POPULATION A total of 27 adult patients (44% female, mean age 30.9 ± 14.8 years) with CHD. FIELD STRENGTH/SEQUENCE A 1.5 T; free-breathing 3D MTC-BOOST sequence. ASSESSMENT MTC-BOOST was compared to diaphragmatic navigator-gated, noncontrast T2 prepared 3D whole-heart imaging sequence (T2prep-3DWH) for comparison of vessel dimensions, lumen-to-myocardium contrast ratio (CR), and image quality (vessel wall sharpness and presence and type of artifacts) assessed by two experienced cardiologists on a 5-point scale. STATISTICAL TESTS Mann-Whitney test, paired Wilcoxon signed-rank test, Bland-Altman plots. P < 0.05 was considered statistically significant. RESULTS MTC-BOOST significantly improved image quality and CR of the right-sided pulmonary veins (PV): (CR: right upper PV 1.06 ± 0.50 vs. 0.58 ± 0.74; right lower PV 1.32 ± 0.38 vs. 0.81 ± 0.73) compared to conventional T2prep-3DWH imaging where the PVs were not visualized in some cases due to off-resonance effects. MTC-BOOST demonstrated resistance to degradation of luminal signal (assessed by CR) secondary to accelerated or turbulent flow conditions. T2prep-3DWH had higher image quality scores than MTC-BOOST for the aorta and coronary arteries; however, great vessel dimensions derived from MTC-BOOST showed excellent agreement with standard T2prep-3DWH imaging. DATA CONCLUSION MTC-BOOST allows for improved contrast-free imaging of pulmonary veins and regions characterized by accelerated or turbulent blood flow compared to standard T2prep-3DWH imaging, with excellent agreement of great vessel dimensions. EVIDENCE LEVEL 1 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Imran Rashid
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.,School of Medicine, Case Western Reserve University, Cleveland, Ohio, USA
| | - Giulia Ginami
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Giovanna Nordio
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Anastasia Fotaki
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Radhouene Neji
- MR Research Collaborations, Siemens Healthcare Limited, Frimley, UK
| | - Harith Alam
- Guy's and St Thomas' Hospital, Department of Cardiology, London, UK
| | - Kuberan Pushparajah
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.,Guy's and St Thomas' Hospital, Department of Cardiology, London, UK
| | | | - Israel Valverde
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.,Paediatric Cardiology Unit, Hospital Virgen del Rocio and Institute of Biomedicine of Seville, IBIS Ciber-CV, Seville, Spain
| | - René M Botnar
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| |
Collapse
|
20
|
The Use of Stress Cardiovascular Imaging in Pediatric Population. CHILDREN (BASEL, SWITZERLAND) 2023; 10:children10020218. [PMID: 36832347 PMCID: PMC9954485 DOI: 10.3390/children10020218] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 01/21/2023] [Accepted: 01/23/2023] [Indexed: 01/28/2023]
Abstract
Although not frequent in the pediatric population, ischemia could occur in children due to several congenital and acquired disease. Stress imaging is key for the non-invasive evaluation of myocardial abnormalities and perfusion defect in this clinical setting. Moreover, beyond ischemia assessment, it can provide complementary diagnostic and prognostic information in valvular heart disease and cardiomyopathies. When performed using cardiovascular magnetic resonance, it could detect, in addition, myocardial fibrosis and infarction, increasing the diagnostic yield. Several imaging modalities are currently available for the evaluation of stress myocardial perfusion. Advances in technologies have also increased the feasibility, safety and availability of these modalities in the pediatric age group. However, despite the established role of stress imaging and its increasing use in daily clinical practice, there are currently no specific guidelines, and little data are available in the literature on this topic. The aim of this review is to summarize the most recent evidence on pediatric stress imaging and its clinical application with a focus on the advantages and limitations of each imaging modality currently available.
Collapse
|
21
|
Si MS, Sood V, Biniwale R, Peng D. Considerations of valvular heart disease in children with ventricular assist devices. Front Cardiovasc Med 2023; 10:1056663. [PMID: 37034354 PMCID: PMC10075362 DOI: 10.3389/fcvm.2023.1056663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Accepted: 03/01/2023] [Indexed: 04/11/2023] Open
Abstract
Ventricular assist devices have become a valuable tool in the treatment of heart failure in children. The use of ventricular assist devices has decreased mortality in children with end-stage heart failure awaiting transplant. It is not uncommon for children with end-stage heart failure associated with cardiomyopathy or congenital heart disease to have significant systemic semilunar and atrioventricular valve regurgitation, which can impact the efficiency and efficacy of hemodynamic support provided by a ventricular assist device. Therefore, implanting clinicians should carefully assess for valve abnormalities that may need repair and impact device selection and cannulation strategy to effectively support this diverse population. The purpose of this review is to provide an overview of this important and relevant topic and to discuss strategies for managing these patients.
Collapse
Affiliation(s)
- Ming-Sing Si
- Department of Pediatrics, Division of Pediatric Cardiology, University of Michigan, C.S. Mott Children’s Hospital, Ann Arbor, MI, United States
- Correspondence: Ming-Sing Si
| | - Vikram Sood
- Department of Cardiac Surgery, C.S. Mott Children's Hospital, University of Michigan, Ann Arbor, MI, United States
| | - Reshma Biniwale
- Department of Pediatrics, Division of Pediatric Cardiology, University of Michigan, C.S. Mott Children’s Hospital, Ann Arbor, MI, United States
| | - David Peng
- Department of Cardiac Surgery, C.S. Mott Children's Hospital, University of Michigan, Ann Arbor, MI, United States
- Department of Surgery, Division of Cardiac Surgery, University of California, Los Angeles, Mattel Children’s Hospital, Los Angeles, CA, United States
| |
Collapse
|
22
|
Abstract
BACKGROUND Limited data exist on training of European paediatric and adult congenital cardiologists. METHODS A structured and approved questionnaire was circulated to national delegates of Association for European Paediatric and Congenital Cardiology in 33 European countries. RESULTS Delegates from 30 countries (91%) responded. Paediatric cardiology was not recognised as a distinct speciality by the respective ministry of Health in seven countries (23%). Twenty countries (67%) have formally accredited paediatric cardiology training programmes, seven (23%) have substantial informal (not accredited or certified) training, and three (10%) have very limited or no programme. Twenty-two countries have a curriculum. Twelve countries have a national training director. There was one paediatric cardiology centre per 2.66 million population (range 0.87-9.64 million), one cardiac surgical centre per 4.73 million population (range 1.63-10.72 million), and one training centre per 4.29 million population (range 1.63-10.72 million population). The median number of paediatric cardiology fellows per training programme was 4 (range 1-17), and duration of training was 3 years (range 2-5 years). An exit examination in paediatric cardiology was conducted in 16 countries (53%) and certification provided by 20 countries (67%). Paediatric cardiologist number is affected by gross domestic product (R2 = 0.41). CONCLUSION Training varies markedly across European countries. Although formal fellowship programmes exist in many countries, several countries have informal training or no training. Only a minority of countries provide both exit examination and certification. Harmonisation of training and standardisation of exit examination and certification could reduce variation in training thereby promoting high-quality care by European congenital cardiologists.
Collapse
|
23
|
Moscatelli S, Borrelli N, Sabatino J, Leo I, Avesani M, Montanaro C, Di Salvo G. Role of Cardiovascular Imaging in the Follow-Up of Patients with Fontan Circulation. CHILDREN (BASEL, SWITZERLAND) 2022; 9:children9121875. [PMID: 36553321 PMCID: PMC9777137 DOI: 10.3390/children9121875] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 11/27/2022] [Accepted: 11/28/2022] [Indexed: 12/02/2022]
Abstract
Since its first description in 1971, the Fontan procedure and its modifications have led to a substantial improvement in the survival rates of patients with a variety of types of complex Congenital Heart Disease (CHD) characterised by the presence of a single, dominant ventricle. However, despite the significant improvement of the prognosis over the years, Fontan patients are still exposed to several cardiovascular and systemic complications. It is, therefore, important to fully understand the pitfalls hidden behind a Fontan anatomy and the potential predictors of ventricular failure. Cardiovascular imaging plays a key role in this context, allowing for the early identification of complications with important prognostic implications. Echocardiography remains the first-line imaging modality for serial evaluation of Fontan patients. However, there is a growing role of cardiovascular magnetic resonance and cardiac computed tomography from pre-operative assessment to longitudinal follow-up. The aim of this paper will be to provide a comprehensive overview of the role, strengths, and weaknesses of each imaging modality in the assessment of congenital cardiac conditions palliated with the Fontan procedure.
Collapse
Affiliation(s)
- Sara Moscatelli
- Paediatric Cardiology Department, Royal Brompton Hospital Harefield NHS Foundation Trust, London SW3 5NP, UK
| | - Nunzia Borrelli
- Adult Congenital Heart Disease Unit, A.O. dei Colli, Monaldi Hospital, 80131 Naples, Italy
| | - Jolanda Sabatino
- Division of Paediatric Cardiology, Department of Women and Children’s Health, University Hospital Padua, 35128 Padua, Italy
- Paediatric Research Institute (IRP), Città Della Speranza, 35127 Padua, Italy
| | - Isabella Leo
- Department of Medical and Surgical Sciences, Magna Grecia University, 88100 Catanzaro, Italy
- Cardiac Magnetic Resonance Department, Royal Brompton Hospital Harefield NHS Foundation Trust, London SW3 5NP, UK
| | - Martina Avesani
- Division of Paediatric Cardiology, Department of Women and Children’s Health, University Hospital Padua, 35128 Padua, Italy
| | - Claudia Montanaro
- Adult Congenital Department, Royal Brompton Hospital & Harefield NHS Foundation Trust, London SW3 5NP, UK
| | - Giovanni Di Salvo
- Division of Paediatric Cardiology, Department of Women and Children’s Health, University Hospital Padua, 35128 Padua, Italy
- Paediatric Research Institute (IRP), Città Della Speranza, 35127 Padua, Italy
- Correspondence:
| |
Collapse
|
24
|
Ferumoxytol-Enhanced Cardiac Magnetic Resonance Angiography and 4D Flow: Safety and Utility in Pediatric and Adult Congenital Heart Disease. CHILDREN (BASEL, SWITZERLAND) 2022; 9:children9121810. [PMID: 36553257 PMCID: PMC9777095 DOI: 10.3390/children9121810] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 10/31/2022] [Accepted: 11/14/2022] [Indexed: 11/27/2022]
Abstract
Cardiac magnetic resonance imaging and angiography have a crucial role in the diagnostic evaluation and follow up of pediatric and adult patients with congenital heart disease. Although much of the information required of advanced imaging studies can be provided by standard gadolinium-enhanced magnetic resonance imaging, the limitations of precise bolus timing, long scan duration, complex imaging protocols, and the need to image small structures limit more widespread use of this modality. Recent experience with off-label diagnostic use of ferumoxytol has helped to mitigate some of these barriers. Approved by the U.S. FDA for intravenous treatment of anemia, ferumoxytol is an ultrasmall superparamagnetic iron oxide nanoparticle that has a long blood pool residence time and high relaxivity. Once metabolized by macrophages, the iron core is incorporated into the reticuloendothelial system. In this work, we aim to summarize the evolution of ferumoxytol-enhanced cardiovascular magnetic resonance imaging and angiography and highlight its many applications for congenital heart disease.
Collapse
|
25
|
Isaak A, Mesropyan N, Hart C, Zhang S, Kravchenko D, Endler C, Katemann C, Weber O, Pieper CC, Kuetting D, Attenberger U, Dabir D, Luetkens JA. Non-contrast free-breathing 3D cardiovascular magnetic resonance angiography using REACT (relaxation-enhanced angiography without contrast) compared to contrast-enhanced steady-state magnetic resonance angiography in complex pediatric congenital heart disease at 3T. J Cardiovasc Magn Reson 2022; 24:55. [PMID: 36384752 PMCID: PMC9670549 DOI: 10.1186/s12968-022-00895-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Accepted: 10/14/2022] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND To evaluate the great vessels in young children with complex congenital heart disease (CHD) using non-contrast cardiovascular magnetic resonance angiography (CMRA) based on three-dimensional relaxation-enhanced angiography without contrast (REACT) in comparison to contrast-enhanced steady-state CMRA. METHODS In this retrospective study from April to July 2021, respiratory- and electrocardiogram-gated native REACT CMRA was compared to contrast-enhanced single-phase steady-state CMRA in children with CHD who underwent CMRA at 3T under deep sedation. Vascular assessment included image quality (1 = non-diagnostic, 5 = excellent), vessel diameter, and diagnostic findings. For statistical analysis, paired t-test, Pearson correlation, Bland-Altman analysis, Wilcoxon test, and intraclass correlation coefficients (ICC) were applied. RESULTS Thirty-six young children with complex CHD (median 4 years, interquartile range, 2-5; 20 males) were included. Native REACT CMRA was obtained successfully in all patients (mean scan time: 4:22 ± 1:44 min). For all vessels assessed, diameters correlated strongly between both methods (Pearson r = 0.99; bias = 0.04 ± 0.61 mm) with high interobserver reproducibility (ICC: 0.99 for both CMRAs). Native REACT CMRA demonstrated comparable overall image quality to contrast-enhanced CMRA (3.9 ± 1.0 vs. 3.8 ± 0.9, P = 0.018). With REACT CMRA, better image quality was obtained at the ascending aorta (4.8 ± 0.5 vs. 4.3 ± 0.8, P < 0.001), coronary roots (e.g., left: 4.1 ± 1.0 vs. 3.3 ± 1.1, P = 0.001), and inferior vena cava (4.6 ± 0.5 vs. 3.2 ± 0.8, P < 0.001). In all patients, additional vascular findings were assessed equally with native REACT CMRA and the contrast-enhanced reference standard (n = 6). CONCLUSION In young children with complex CHD, REACT CMRA can provide gadolinium-free high image quality, accurate vascular measurements, and equivalent diagnostic quality compared to standard contrast-enhanced CMRA.
Collapse
Affiliation(s)
- Alexander Isaak
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.
- Quantitative Imaging Lab Bonn (QILaB), Bonn, Germany.
| | - Narine Mesropyan
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
- Quantitative Imaging Lab Bonn (QILaB), Bonn, Germany
| | - Christopher Hart
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
- Department of Pediatric Cardiology, University Hospital Bonn, Bonn, Germany
| | - Shuo Zhang
- Philips GmbH Market DACH, Hamburg, Germany
| | - Dmitrij Kravchenko
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
- Quantitative Imaging Lab Bonn (QILaB), Bonn, Germany
| | - Christoph Endler
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
- Quantitative Imaging Lab Bonn (QILaB), Bonn, Germany
| | | | | | - Claus C Pieper
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Daniel Kuetting
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
- Quantitative Imaging Lab Bonn (QILaB), Bonn, Germany
| | - Ulrike Attenberger
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Darius Dabir
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
- Quantitative Imaging Lab Bonn (QILaB), Bonn, Germany
| | - Julian A Luetkens
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
- Quantitative Imaging Lab Bonn (QILaB), Bonn, Germany
| |
Collapse
|
26
|
Yanovskiy A, Martelius L, Rahkonen O, Pihkala J, Happonen JM, Boldt T, Jaakkola I, Peltonen J, Kortesniemi M, Mattila I, Ojala T. Institutional transition from invasive to non-invasive imaging in children with univentricular heart defects: safety and cost savings. Cardiol Young 2022; 33:1-7. [PMID: 35993406 DOI: 10.1017/s1047951122002207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/17/2023]
Abstract
OBJECTIVES Patients with univentricular heart defects require lifelong imaging surveillance. Recent advances in non-invasive imaging have enabled replacing these patients' routine catheterisation. Our objective was to describe the safety and cost savings of transition of a tertiary care children's hospital from routine invasive to routine non-invasive imaging of low-risk patients with univentricular heart defects. METHODS This single-centre cohort study consists of 1) a retrospective analysis of the transition from cardiac catheterisation (n = 21) to CT angiography (n = 20) before bidirectional Glenn operation and 2) a prospective study (n = 89) describing cardiac magnetic resonance before and after the total cavopulmonary connection in low-risk patients with univentricular heart defects. RESULTS Pre-Glenn: The total length of CT angiography was markedly shorter compared to the catheterisation: 30 min (range: 20-60) and 125 min (range: 70-220), respectively (p < 0.001). Catheterisation used more iodine contrast agents than CT angiography, 19 ± 3.9 ml, and 10 ± 2.4 ml, respectively (p < 0.001). Controlled ventilation was used for all catheterised and 3 (15%) CT angiography patients (p < 0.001). No complications occurred during CT angiography, while they emerged in 19% (4/21) catheterisation cases (p < 0.001). CT angiography and catheterisation showed no significant difference in the radiation exposure. Pre-/post-total cavopulmonary connection: All cardiac magnetic resonance studies were successful, and no complications occurred. In 60% of the cardiac magnetic resonance (53/89), no sedation was performed, and peripheral venous pressure was measured in all cases. Cost analysis suggests that moving to non-invasive imaging yielded cost savings of at least €2500-4000 per patient. CONCLUSION Transition from routine invasive to routine non-invasive pre-and post-operative imaging is safely achievable with cost savings.
Collapse
Affiliation(s)
- Anna Yanovskiy
- HUS Medical Imaging Center, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| | - Laura Martelius
- HUS Medical Imaging Center, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| | - Otto Rahkonen
- Department of Pediatric Cardiology, New Children's Hospital, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| | - Jaana Pihkala
- Department of Pediatric Cardiology, New Children's Hospital, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| | - Juha-Matti Happonen
- Department of Pediatric Cardiology, New Children's Hospital, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| | - Talvikki Boldt
- Department of Pediatric Cardiology, New Children's Hospital, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| | - Ilkka Jaakkola
- Department of Pediatric Cardiology, New Children's Hospital, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| | - Juha Peltonen
- HUS Medical Imaging Center, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| | - Mika Kortesniemi
- HUS Medical Imaging Center, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| | - Ilkka Mattila
- Pediatric Cardiac and Transplantation Surgery, HUS New Children's Hospital, Helsinki University Hospital, Helsinki, Finland
| | - Tiina Ojala
- Department of Pediatric Cardiology, New Children's Hospital, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| |
Collapse
|
27
|
Fogel MA, Anwar S, Broberg C, Browne L, Chung T, Johnson T, Muthurangu V, Taylor M, Valsangiacomo-Buechel E, Wilhelm C. Society for Cardiovascular Magnetic Resonance/European Society of Cardiovascular Imaging/American Society of Echocardiography/Society for Pediatric Radiology/North American Society for Cardiovascular Imaging Guidelines for the use of cardiovascular magnetic resonance in pediatric congenital and acquired heart disease : Endorsed by The American Heart Association. J Cardiovasc Magn Reson 2022; 24:37. [PMID: 35725473 PMCID: PMC9210755 DOI: 10.1186/s12968-022-00843-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Accepted: 01/12/2022] [Indexed: 11/16/2022] Open
Abstract
Cardiovascular magnetic resonance (CMR) has been utilized in the management and care of pediatric patients for nearly 40 years. It has evolved to become an invaluable tool in the assessment of the littlest of hearts for diagnosis, pre-interventional management and follow-up care. Although mentioned in a number of consensus and guidelines documents, an up-to-date, large, stand-alone guidance work for the use of CMR in pediatric congenital 36 and acquired 35 heart disease endorsed by numerous Societies involved in the care of these children is lacking. This guidelines document outlines the use of CMR in this patient population for a significant number of heart lesions in this age group and although admittedly, is not an exhaustive treatment, it does deal with an expansive list of many common clinical issues encountered in daily practice.
Collapse
Affiliation(s)
- Mark A Fogel
- Departments of Pediatrics (Cardiology) and Radiology, The Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA. .,Division of Cardiology, Department of Pediatrics, The Children's Hospital of Philadelphia, Philadelphia, PA, USA.
| | - Shaftkat Anwar
- Department of Pediatrics (Cardiology) and Radiology, The University of California-San Francisco School of Medicine, San Francisco, USA
| | - Craig Broberg
- Division of Cardiovascular Medicine, Oregon Health and Sciences University, Portland, USA
| | - Lorna Browne
- Department of Radiology, University of Colorado, Denver, USA
| | - Taylor Chung
- Department of Radiology and Biomedical Imaging, The University of California-San Francisco School of Medicine, San Francisco, USA
| | - Tiffanie Johnson
- Department of Pediatrics (Cardiology), Indiana University School of Medicine, Indianapolis, USA
| | - Vivek Muthurangu
- Department of Pediatrics (Cardiology), University College London, London, UK
| | - Michael Taylor
- Department of Pediatrics (Cardiology), University of Cincinnati School of Medicine, Cincinnati, USA
| | | | - Carolyn Wilhelm
- Department of Pediatrics (Cardiology), University Hospitals-Cleveland, Cleaveland, USA
| |
Collapse
|
28
|
Fogel MA, Anwar S, Broberg C, Browne L, Chung T, Johnson T, Muthurangu V, Taylor M, Valsangiacomo-Buechel E, Wilhelm C. Society for Cardiovascular Magnetic Resonance/European Society of Cardiovascular Imaging/American Society of Echocardiography/Society for Pediatric Radiology/North American Society for Cardiovascular Imaging Guidelines for the Use of Cardiac Magnetic Resonance in Pediatric Congenital and Acquired Heart Disease: Endorsed by The American Heart Association. Circ Cardiovasc Imaging 2022; 15:e014415. [PMID: 35727874 PMCID: PMC9213089 DOI: 10.1161/circimaging.122.014415] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
Cardiovascular magnetic resonance has been utilized in the management and care of pediatric patients for nearly 40 years. It has evolved to become an invaluable tool in the assessment of the littlest of hearts for diagnosis, pre-interventional management and follow-up care. Although mentioned in a number of consensus and guidelines documents, an up-to-date, large, stand-alone guidance work for the use of cardiovascular magnetic resonance in pediatric congenital 36 and acquired 35 heart disease endorsed by numerous Societies involved in the care of these children is lacking. This guidelines document outlines the use of cardiovascular magnetic resonance in this patient population for a significant number of heart lesions in this age group and although admittedly, is not an exhaustive treatment, it does deal with an expansive list of many common clinical issues encountered in daily practice.
Collapse
Affiliation(s)
- Mark A Fogel
- Departments of Pediatrics (Cardiology) and Radiology, The Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA, (M.A.F.).,Division of Cardiology, Department of Pediatrics, The Children's Hospital of Philadelphia, Philadelphia, PA, USA, (M.A.F.)
| | - Shaftkat Anwar
- Department of Pediatrics (Cardiology) and Radiology, The University of California-San Francisco School of Medicine, San Francisco, USA, (S.A.)
| | - Craig Broberg
- Division of Cardiovascular Medicine, Oregon Health and Sciences University, Portland, USA, (C.B.)
| | - Lorna Browne
- Department of Radiology, University of Colorado, Denver, USA, (L.B.)
| | - Taylor Chung
- Department of Radiology and Biomedical Imaging, The University of California-San Francisco School of Medicine, San Francisco, USA, (T.C.)
| | - Tiffanie Johnson
- Department of Pediatrics (Cardiology), Indiana University School of Medicine, Indianapolis, USA, (T.J.)
| | - Vivek Muthurangu
- Department of Pediatrics (Cardiology), University College London, London, UK, (V.M.)
| | - Michael Taylor
- Department of Pediatrics (Cardiology), University of Cincinnati School of Medicine, Cincinnati, USA, (M.T.)
| | | | - Carolyn Wilhelm
- Department of Pediatrics (Cardiology), University Hospitals-Cleveland, Cleaveland, USA (C.W.)
| |
Collapse
|
29
|
Puricelli F, Voges I, Gatehouse P, Rigby M, Izgi C, Pennell DJ, Krupickova S. Performance of Cardiac MRI in Pediatric and Adult Patients with Fontan Circulation. Radiol Cardiothorac Imaging 2022; 4:e210235. [PMID: 35833165 PMCID: PMC9274315 DOI: 10.1148/ryct.210235] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2021] [Revised: 04/11/2022] [Accepted: 04/18/2022] [Indexed: 06/15/2023]
Abstract
Cardiac MRI has become a widely accepted standard for anatomic and functional assessment of complex Fontan physiology, because it is noninvasive and suitable for comprehensive follow-up evaluation after Fontan completion. The use of cardiac MRI in pediatric and adult patients after completion of the Fontan procedure are described, and a practical and experience-based cardiac MRI protocol for evaluating these patients is provided. The current approach and study protocol in use at the authors' institution are presented, which address technical considerations concerning sequences, planning, and optimal image acquisition in patients with Fontan circulation. Additionally, for each sequence, the information that can be obtained and guidance on how to integrate it into clinical decision-making is discussed. Keywords: Pediatrics, MRI, MRI Functional Imaging, Heart, Congenital © RSNA, 2022.
Collapse
|
30
|
Recommendations for cardiovascular magnetic resonance and computed tomography in congenital heart disease: a consensus paper from the CMR/CCT working group of the Italian Society of Pediatric Cardiology (SICP) and the Italian College of Cardiac Radiology endorsed by the Italian Society of Medical and Interventional Radiology (SIRM) Part I. Radiol Med 2022; 127:788-802. [PMID: 35608758 PMCID: PMC9308607 DOI: 10.1007/s11547-022-01490-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Accepted: 03/23/2022] [Indexed: 11/23/2022]
Abstract
Cardiovascular magnetic resonance (CMR) and computed tomography (CCT) are advanced imaging modalities that recently revolutionized the conventional diagnostic approach to congenital heart diseases (CHD), supporting echocardiography and often replacing cardiac catheterization. Nevertheless, correct execution and interpretation require in-depth knowledge of all technical and clinical aspects of CHD, a careful assessment of risks and benefits before each exam, proper imaging protocols to maximize diagnostic information, minimizing harm. This position paper, written by experts from the Working Group of the Italian Society of Pediatric Cardiology and from the Italian College of Cardiac Radiology of the Italian Society of Medical and Interventional Radiology, is intended as a practical guide for applying CCT and CMR in children and adults with CHD, wishing to support Radiologists, Pediatricians, Cardiologists and Cardiac Surgeons in the multimodality diagnostic approach to these patients. The first part provides a review of the most relevant literature in the field, describes each modality's advantage and drawback, making considerations on the main applications, image quality, and safety issues. The second part focuses on clinical indications and appropriateness criteria for CMR and CCT, considering the level of CHD complexity, the clinical and logistic setting and the operator expertise.
Collapse
|
31
|
Transcatheter Device Therapy and the Integration of Advanced Imaging in Congenital Heart Disease. CHILDREN 2022; 9:children9040497. [PMID: 35455541 PMCID: PMC9032030 DOI: 10.3390/children9040497] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Revised: 03/27/2022] [Accepted: 03/29/2022] [Indexed: 01/04/2023]
Abstract
Transcatheter device intervention is now offered as first line therapy for many congenital heart defects (CHD) which were traditionally treated with cardiac surgery. While off-label use of devices is common and appropriate, a growing number of devices are now specifically designed and approved for use in CHD. Advanced imaging is now an integral part of interventional procedures including pre-procedure planning, intra-procedural guidance, and post-procedure monitoring. There is robust societal and industrial support for research and development of CHD-specific devices, and the regulatory framework at the national and international level is patient friendly. It is against this backdrop that we review transcatheter implantable devices for CHD, the role and integration of advanced imaging, and explore the current regulatory framework for device approval.
Collapse
|
32
|
Influence of Subcutaneous Implantable Defibrillators on Cardiovascular Magnetic Resonance Image Quality in Pediatric Patients. HeartRhythm Case Rep 2022; 8:509-514. [PMID: 35860767 PMCID: PMC9289066 DOI: 10.1016/j.hrcr.2022.04.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
33
|
Ramirez-Suarez KI, Tierradentro-García LO, Otero HJ, Rapp JB, White AM, Partington SL, Harris MA, Vatsky SA, Whitehead KK, Fogel MA, Biko DM. Optimizing neonatal cardiac imaging (magnetic resonance/computed tomography). Pediatr Radiol 2022; 52:661-675. [PMID: 34657169 DOI: 10.1007/s00247-021-05201-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Revised: 07/28/2021] [Accepted: 09/01/2021] [Indexed: 10/20/2022]
Abstract
Magnetic resonance imaging (MRI) and CT perform an important role in the evaluation of neonates with congenital heart disease (CHD) when echocardiography is not sufficient for surgical planning or postoperative follow-up. Cardiac MRI and cardiac CT have complementary applications in the evaluation of cardiovascular disease in neonates. This review focuses on the indications and technical aspects of these modalities and special considerations for imaging neonates with CHD.
Collapse
Affiliation(s)
- Karen I Ramirez-Suarez
- Roberts Center for Pediatric Research, Children's Hospital of Philadelphia, 734 Schuylkill Ave, Philadelphia, PA, 19146, USA. .,Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA.
| | - Luis Octavio Tierradentro-García
- Roberts Center for Pediatric Research, Children's Hospital of Philadelphia, 734 Schuylkill Ave, Philadelphia, PA, 19146, USA.,Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Hansel J Otero
- Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA.,Perelman School of Medicine at The University of Pennsylvania, Philadelphia, PA, USA
| | - Jordan B Rapp
- Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA.,Perelman School of Medicine at The University of Pennsylvania, Philadelphia, PA, USA
| | - Ammie M White
- Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA.,Perelman School of Medicine at The University of Pennsylvania, Philadelphia, PA, USA
| | - Sara L Partington
- Division of Cardiology, Department of Pediatrics, Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Matthew A Harris
- Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA.,Perelman School of Medicine at The University of Pennsylvania, Philadelphia, PA, USA.,Division of Cardiology, Department of Pediatrics, Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Seth A Vatsky
- Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA.,Perelman School of Medicine at The University of Pennsylvania, Philadelphia, PA, USA
| | - Kevin K Whitehead
- Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA.,Perelman School of Medicine at The University of Pennsylvania, Philadelphia, PA, USA.,Division of Cardiology, Department of Pediatrics, Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Mark A Fogel
- Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA.,Perelman School of Medicine at The University of Pennsylvania, Philadelphia, PA, USA.,Division of Cardiology, Department of Pediatrics, Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - David M Biko
- Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA.,Perelman School of Medicine at The University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
34
|
Curione D, Ciliberti P, Monti CB, Capra D, Bordonaro V, Ciancarella P, Santangelo TP, Napolitano C, Ferrara D, Perrone MA, Secchi F, Secinaro A. Compressed Sensing Cardiac Cine Imaging Compared with Standard Balanced Steady-State Free Precession Cine Imaging in a Pediatric Population. Radiol Cardiothorac Imaging 2022; 4:e210109. [PMID: 35506130 DOI: 10.1148/ryct.210109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2021] [Revised: 03/21/2022] [Accepted: 03/29/2022] [Indexed: 11/11/2022]
Abstract
Purpose To compare real-time compressed sensing (CS) and standard balanced steady-state free precession (bSSFP) cardiac cine imaging in children. Materials and Methods Twenty children (mean age, 15 years ± 5 [SD], range, 7-21 years; 10 male participants) with biventricular congenital heart disease (n = 11) or cardiomyopathy (n = 9) were prospectively included. Examinations were performed with 1.5-T imagers by using both bSSFP and CS sequences in all participants. Quantification of ventricular volumes and function was performed for all images by two readers blinded to patient diagnosis and type of sequence. Values were correlated with phase-contrast flow measurements by one reader. Intra- and interreader agreement were analyzed. Results There were no significant differences between ventricular parameters measured on CS compared with those of bSSFP (P > .05) for reader 1. Only ejection fraction showed a significant difference (P = .02) for reader 2. Intrareader agreement was considerable for both sequences (bSSFP: mean difference range, +1 to -2.6; maximum CI, +7.9, -13; bias range, 0.1%-4.1%; intraclass correlation coefficient [ICC] range, 0.931-0.997. CS: mean difference range, +7.4 to -5.6; maximum CI, +37.2, -48.8; bias range, 0.5%-7.5%; ICC range, 0.717-0.997). Interreader agreement was acceptable but less robust, especially for CS (bSSFP: mean difference range, +2.6 to -5.6; maximum CI, +60.7, -65.3; bias range, 1.6%-6.2%; ICC range, 0.726-0.951. CS: mean difference range, +10.7 to -9.1; maximum CI, +87.5, -84.6; bias range, 1.1%-17.3%; ICC range, 0.509-0.849). The mean acquisition time was shorter for CS (20 seconds; range, 17-25 seconds) compared with that for bSSFP (160 seconds; range, 130-190 seconds) (P < .001). Conclusion CS cardiac cine imaging provided equivalent ventricular volume and function measurements with shorter acquisition times compared with those of bSSFP and may prove suitable for the pediatric population.Keywords: Compressed Sensing, Balanced Steady-State Free Precession, Cine Imaging, Cardiovascular MRI, Pediatrics, Cardiac, Heart, Cardiomyopathies, Congenital, Segmentation© RSNA, 2022.
Collapse
Affiliation(s)
- Davide Curione
- Advanced Cardiovascular Radiology Unit, Department of Radiology and Bioimaging (D. Curione, V.B., P. Ciancarella, T.P.S., C.N., A.S.), and Department of Pediatric Cardiology and Cardiac Surgery (P. Ciliberti, M.A.P.), Bambino Gesù Children's Hospital IRCCS, Piazza Sant'Onofrio 4, 00165 Rome, Italy; Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy (C.B.M., D. Capra, F.S.); Department of Radiology, Santobono-Pausilipon Children's Hospital, Naples, Italy (D.F.); and Unit of Radiology, IRCCS Policlinco San Donato, San Donato Milanese, Italy (F.S.)
| | - Paolo Ciliberti
- Advanced Cardiovascular Radiology Unit, Department of Radiology and Bioimaging (D. Curione, V.B., P. Ciancarella, T.P.S., C.N., A.S.), and Department of Pediatric Cardiology and Cardiac Surgery (P. Ciliberti, M.A.P.), Bambino Gesù Children's Hospital IRCCS, Piazza Sant'Onofrio 4, 00165 Rome, Italy; Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy (C.B.M., D. Capra, F.S.); Department of Radiology, Santobono-Pausilipon Children's Hospital, Naples, Italy (D.F.); and Unit of Radiology, IRCCS Policlinco San Donato, San Donato Milanese, Italy (F.S.)
| | - Caterina Beatrice Monti
- Advanced Cardiovascular Radiology Unit, Department of Radiology and Bioimaging (D. Curione, V.B., P. Ciancarella, T.P.S., C.N., A.S.), and Department of Pediatric Cardiology and Cardiac Surgery (P. Ciliberti, M.A.P.), Bambino Gesù Children's Hospital IRCCS, Piazza Sant'Onofrio 4, 00165 Rome, Italy; Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy (C.B.M., D. Capra, F.S.); Department of Radiology, Santobono-Pausilipon Children's Hospital, Naples, Italy (D.F.); and Unit of Radiology, IRCCS Policlinco San Donato, San Donato Milanese, Italy (F.S.)
| | - Davide Capra
- Advanced Cardiovascular Radiology Unit, Department of Radiology and Bioimaging (D. Curione, V.B., P. Ciancarella, T.P.S., C.N., A.S.), and Department of Pediatric Cardiology and Cardiac Surgery (P. Ciliberti, M.A.P.), Bambino Gesù Children's Hospital IRCCS, Piazza Sant'Onofrio 4, 00165 Rome, Italy; Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy (C.B.M., D. Capra, F.S.); Department of Radiology, Santobono-Pausilipon Children's Hospital, Naples, Italy (D.F.); and Unit of Radiology, IRCCS Policlinco San Donato, San Donato Milanese, Italy (F.S.)
| | - Veronica Bordonaro
- Advanced Cardiovascular Radiology Unit, Department of Radiology and Bioimaging (D. Curione, V.B., P. Ciancarella, T.P.S., C.N., A.S.), and Department of Pediatric Cardiology and Cardiac Surgery (P. Ciliberti, M.A.P.), Bambino Gesù Children's Hospital IRCCS, Piazza Sant'Onofrio 4, 00165 Rome, Italy; Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy (C.B.M., D. Capra, F.S.); Department of Radiology, Santobono-Pausilipon Children's Hospital, Naples, Italy (D.F.); and Unit of Radiology, IRCCS Policlinco San Donato, San Donato Milanese, Italy (F.S.)
| | - Paolo Ciancarella
- Advanced Cardiovascular Radiology Unit, Department of Radiology and Bioimaging (D. Curione, V.B., P. Ciancarella, T.P.S., C.N., A.S.), and Department of Pediatric Cardiology and Cardiac Surgery (P. Ciliberti, M.A.P.), Bambino Gesù Children's Hospital IRCCS, Piazza Sant'Onofrio 4, 00165 Rome, Italy; Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy (C.B.M., D. Capra, F.S.); Department of Radiology, Santobono-Pausilipon Children's Hospital, Naples, Italy (D.F.); and Unit of Radiology, IRCCS Policlinco San Donato, San Donato Milanese, Italy (F.S.)
| | - Teresa Pia Santangelo
- Advanced Cardiovascular Radiology Unit, Department of Radiology and Bioimaging (D. Curione, V.B., P. Ciancarella, T.P.S., C.N., A.S.), and Department of Pediatric Cardiology and Cardiac Surgery (P. Ciliberti, M.A.P.), Bambino Gesù Children's Hospital IRCCS, Piazza Sant'Onofrio 4, 00165 Rome, Italy; Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy (C.B.M., D. Capra, F.S.); Department of Radiology, Santobono-Pausilipon Children's Hospital, Naples, Italy (D.F.); and Unit of Radiology, IRCCS Policlinco San Donato, San Donato Milanese, Italy (F.S.)
| | - Carmela Napolitano
- Advanced Cardiovascular Radiology Unit, Department of Radiology and Bioimaging (D. Curione, V.B., P. Ciancarella, T.P.S., C.N., A.S.), and Department of Pediatric Cardiology and Cardiac Surgery (P. Ciliberti, M.A.P.), Bambino Gesù Children's Hospital IRCCS, Piazza Sant'Onofrio 4, 00165 Rome, Italy; Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy (C.B.M., D. Capra, F.S.); Department of Radiology, Santobono-Pausilipon Children's Hospital, Naples, Italy (D.F.); and Unit of Radiology, IRCCS Policlinco San Donato, San Donato Milanese, Italy (F.S.)
| | - Dolores Ferrara
- Advanced Cardiovascular Radiology Unit, Department of Radiology and Bioimaging (D. Curione, V.B., P. Ciancarella, T.P.S., C.N., A.S.), and Department of Pediatric Cardiology and Cardiac Surgery (P. Ciliberti, M.A.P.), Bambino Gesù Children's Hospital IRCCS, Piazza Sant'Onofrio 4, 00165 Rome, Italy; Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy (C.B.M., D. Capra, F.S.); Department of Radiology, Santobono-Pausilipon Children's Hospital, Naples, Italy (D.F.); and Unit of Radiology, IRCCS Policlinco San Donato, San Donato Milanese, Italy (F.S.)
| | - Marco Alfonso Perrone
- Advanced Cardiovascular Radiology Unit, Department of Radiology and Bioimaging (D. Curione, V.B., P. Ciancarella, T.P.S., C.N., A.S.), and Department of Pediatric Cardiology and Cardiac Surgery (P. Ciliberti, M.A.P.), Bambino Gesù Children's Hospital IRCCS, Piazza Sant'Onofrio 4, 00165 Rome, Italy; Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy (C.B.M., D. Capra, F.S.); Department of Radiology, Santobono-Pausilipon Children's Hospital, Naples, Italy (D.F.); and Unit of Radiology, IRCCS Policlinco San Donato, San Donato Milanese, Italy (F.S.)
| | - Francesco Secchi
- Advanced Cardiovascular Radiology Unit, Department of Radiology and Bioimaging (D. Curione, V.B., P. Ciancarella, T.P.S., C.N., A.S.), and Department of Pediatric Cardiology and Cardiac Surgery (P. Ciliberti, M.A.P.), Bambino Gesù Children's Hospital IRCCS, Piazza Sant'Onofrio 4, 00165 Rome, Italy; Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy (C.B.M., D. Capra, F.S.); Department of Radiology, Santobono-Pausilipon Children's Hospital, Naples, Italy (D.F.); and Unit of Radiology, IRCCS Policlinco San Donato, San Donato Milanese, Italy (F.S.)
| | - Aurelio Secinaro
- Advanced Cardiovascular Radiology Unit, Department of Radiology and Bioimaging (D. Curione, V.B., P. Ciancarella, T.P.S., C.N., A.S.), and Department of Pediatric Cardiology and Cardiac Surgery (P. Ciliberti, M.A.P.), Bambino Gesù Children's Hospital IRCCS, Piazza Sant'Onofrio 4, 00165 Rome, Italy; Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy (C.B.M., D. Capra, F.S.); Department of Radiology, Santobono-Pausilipon Children's Hospital, Naples, Italy (D.F.); and Unit of Radiology, IRCCS Policlinco San Donato, San Donato Milanese, Italy (F.S.)
| |
Collapse
|
35
|
Buddhe S, Soriano BD, Powell AJ. Survey of centers performing cardiovascular magnetic resonance in pediatric and congenital heart disease: a report of the Society for Cardiovascular Magnetic Resonance. J Cardiovasc Magn Reson 2022; 24:10. [PMID: 35109865 PMCID: PMC8812017 DOI: 10.1186/s12968-021-00830-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Accepted: 11/22/2021] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND There are few data on practice patterns and trends for cardiovascular magnetic resonance (CMR) in pediatric and congenital heart disease. The Society for Cardiovascular Magnetic Resonance (SCMR) sought to address this deficiency by performing an international survey of CMR centers. METHODS Surveys consisting of 31 (2014) and 33 (2018) items were designed to collect data on the use of CMR for the evaluation of pediatric and congenital heart disease patients. They were sent to all SCMR members in 2014 and 2018. One response per center was collected. RESULTS There were 93 centers that responded in 2014 and 83 in 2018. The results that follow show data from 2014 and 2018 separated by a dash. The median annual number of pediatric/congenital CMR cases per center was 183-209. The median number of scanners for CMR was 2-2 (range, 1-8) with 58-63% using only 1.5T scanners and 4-4% using only 3T scanners. The mean number of attending/staff reading CMRs was 3.7-2.6; among them, 52-61% were pediatric or adult cardiologists and 47-38% were pediatric or adult radiologists. The median annual case volume per attending was 54-86. The median number of technologists per center doing CMRs was 4-5. The median scanner time allocated for a non-sedated examination was 75-75 min (range, 45-120). Among the 21 centers responding to both surveys, the mean annual case volume increased from 320 in 2014 to 445 in 2018; 17 (81%) of the centers had an increase in annual case volume. For this subgroup, the median attending/staff per center was 4 in both 2014 and 2018. The median scanner time allotted per study was unchanged at 90 min. The mean time for an attending/staff physician to perform a typical CMR examination including reporting was 143-141 min. CONCLUSION These survey data provide a novel comprehensive view of CMR practice in pediatric and congenital heart disease. This information is useful for internal benchmarking, resource allocation, addressing practice variation, quality improvement initiatives, and identifying unmet needs.
Collapse
Affiliation(s)
- Sujatha Buddhe
- Division of Cardiology, Department of Pediatrics, University of Washington School of Medicine and Seattle Children's Hospital, Seattle, WA, USA.
| | - Brian D Soriano
- Division of Cardiology, Department of Pediatrics, University of Washington School of Medicine and Seattle Children's Hospital, Seattle, WA, USA
| | - Andrew J Powell
- Department of Cardiology, Department of Pediatrics, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
36
|
Garg A, Azad S, Kumar K, Bhatia M, Radhakrishnan S. Role of Cardiac Magnetic Resonance Imaging in Hypocalcemia-Induced Dilated Cardiomyopathy in Pediatric Population. Indian J Radiol Imaging 2022; 31:837-843. [PMID: 35136494 PMCID: PMC8817823 DOI: 10.1055/s-0041-1740541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Background
Hypocalcemia is a rare reversible cause of dilated cardiomyopathy in pediatric population. Myocarditis is another more frequent cause of cardiomyopathy with overlapping presenting features. Cardiac magnetic resonance imaging (CMRI) is a vital modality capable of tissue characterization for the evaluation of cardiomyopathy. The present study is the first attempt to determine if any specific characteristics on CMR exist in patients with hypocalcemic dilated cardiomyopathy.
Methods
A retrospective analysis of 10 cases of hypocalcemic dilated cardiomyopathy (August 2012–August 2019), among which CMRI of nine patients were analyzed. Patients were categorized in to three categories; category 1 defined as absence of edema and late gadolinium enhancement (LGE), category 2 having edema only, and category 3 with presence of both edema and LGE. A diagnosis of myocarditis was considered if both edema and LGE were present.
Results
The mean age of the cohort was 5.5 ± 3.3 months. The mean ejection fraction of the cohort was 20.5 ± 6.85% that improved significantly to 35.22 ± 9.3% at the time of discharge. Five of nine patients had no edema or LGE (category 1), whereas two patients each were categorized into category 2 and 3. All cases in category 1 had normalized ventricular function on follow-up. One patient in category 2 had normal ejection fraction and one was lost to follow-up. Out of the two patients in category 3, there was one mortality and another was lost to follow-up. Of the six patients at follow-up (19 ± 11.0 months), the mean left ventricle ejection fraction improved to 56.5 ± 6.1%.
Conclusion
Hypocalcemic dilated cardiomyopathy has a favorable outcome on rapid initiation of treatment. CMR can be utilized for further prognostication of these patients. Absence of edema and LGE predicts a good outcome, whereas presence of LGE and/or edema either indicates a worse prognosis or an underlying coexistent myocarditis warranting an early myocardial biopsy.
Collapse
Affiliation(s)
- Ankit Garg
- Department of Pediatric Cardiology, Fortis Escorts Heart Institute, New Delhi, India
| | - Sushil Azad
- Department of Pediatric Cardiology, Fortis Escorts Heart Institute, New Delhi, India
| | - Khemendra Kumar
- Department of Radiodiagnosis, Fortis Escorts Heart Institute, New Delhi, India
| | - Mona Bhatia
- Department of Radiodiagnosis, Fortis Escorts Heart Institute, New Delhi, India
| | - S. Radhakrishnan
- Department of Pediatric Cardiology, Fortis Escorts Heart Institute, New Delhi, India
| |
Collapse
|
37
|
Franson D, Dupuis A, Gulani V, Griswold M, Seiberlich N. A System for Real-Time, Online Mixed-Reality Visualization of Cardiac Magnetic Resonance Images. J Imaging 2021; 7:jimaging7120274. [PMID: 34940741 PMCID: PMC8709155 DOI: 10.3390/jimaging7120274] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Revised: 12/07/2021] [Accepted: 12/09/2021] [Indexed: 11/16/2022] Open
Abstract
Image-guided cardiovascular interventions are rapidly evolving procedures that necessitate imaging systems capable of rapid data acquisition and low-latency image reconstruction and visualization. Compared to alternative modalities, Magnetic Resonance Imaging (MRI) is attractive for guidance in complex interventional settings thanks to excellent soft tissue contrast and large fields-of-view without exposure to ionizing radiation. However, most clinically deployed MRI sequences and visualization pipelines exhibit poor latency characteristics, and spatial integration of complex anatomy and device orientation can be challenging on conventional 2D displays. This work demonstrates a proof-of-concept system linking real-time cardiac MR image acquisition, online low-latency reconstruction, and a stereoscopic display to support further development in real-time MR-guided intervention. Data are acquired using an undersampled, radial trajectory and reconstructed via parallelized through-time radial generalized autocalibrating partially parallel acquisition (GRAPPA) implemented on graphics processing units. Images are rendered for display in a stereoscopic mixed-reality head-mounted display. The system is successfully tested by imaging standard cardiac views in healthy volunteers. Datasets comprised of one slice (46 ms), two slices (92 ms), and three slices (138 ms) are collected, with the acquisition time of each listed in parentheses. Images are displayed with latencies of 42 ms/frame or less for all three conditions. Volumetric data are acquired at one volume per heartbeat with acquisition times of 467 ms and 588 ms when 8 and 12 partitions are acquired, respectively. Volumes are displayed with a latency of 286 ms or less. The faster-than-acquisition latencies for both planar and volumetric display enable real-time 3D visualization of the heart.
Collapse
Affiliation(s)
- Dominique Franson
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA;
- Correspondence: (D.F.); (A.D.)
| | - Andrew Dupuis
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA;
- Correspondence: (D.F.); (A.D.)
| | - Vikas Gulani
- Department of Radiology, University of Michigan, Ann Arbor, MI 48109, USA; (V.G.); (N.S.)
| | - Mark Griswold
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA;
- Department of Radiology, Case Western Reserve University, Cleveland, OH 44106, USA
| | - Nicole Seiberlich
- Department of Radiology, University of Michigan, Ann Arbor, MI 48109, USA; (V.G.); (N.S.)
| |
Collapse
|
38
|
Gamal El-Deen MA, Ibrahim AS, Abdeldayem EH, Elia RZ, Romeih S. Assessment of superior cavo-pulmonary anastomoses (Glenn shunt) by cardiac magnetic resonance imaging in comparison with multi-slice computed tomography. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2021. [DOI: 10.1186/s43055-021-00676-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
Multi-slice computed tomography (MSCT) angiography is the gold standard imaging modality to evaluate the patency of Glenn shunt and the presence of veno–veno collaterals. The goal of this study is to evaluate the ability of two cardiac magnetic resonance imaging (MRI) techniques to assess the patency of Glenn shunt and the presence of veno–veno collaterals compared to MSCT angiography.
Results
Patients with Glenn shunt had MSCT angiography and cardiac MRI using two techniques: TWIST (Time-resolved angiography With Stochastic Trajectories) and the three-dimensional (3D) post-contrast whole heart techniques. MSCT angiography and cardiac MRI images were post-processed for quantitative and qualitative assessment of Glenn shunt and veno–veno collaterals. Our study included 29 patients (17 male, 59%) with Glenn shunt, the median age was 22 years (range 3–36 years). 3D post-contrast whole heart images give similar results compared to MSCT angiography results in the evaluation of Glenn shunt and veno–veno collaterals, 100% agreement in Glenn shunt visualization and agreement was 86.2% in the detection of veno–veno collaterals with a perfect agreement (kappa = 1) as regards their proximal connection to superior vena cava (SVC). While TWIST showed lower agreement compared to MSCT angiography results, 87.5% agreement in Glenn shunt visualization and agreement was 68.9% in the detection of veno–veno collaterals with poor agreement (kappa = 0.266) as regards their proximal connection to SVC.
Conclusions
3D post-contrast whole heart MRI images have similar results as MSCT angiography in the evaluation of superior cavo-pulmonary anastomosis and can be a good and safer alternative to MSCT angiography.
Collapse
|
39
|
Saraya S, Ahmad YM, Soliman HH, Saraya M, Louis M. Validity of cardiovascular magnetic resonance in pre- and post-operative evaluation of pulmonary arteries and ventricular functions in pediatric conotruncal anomalies. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2021. [DOI: 10.1186/s43055-021-00510-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
The aim of this work is to evaluate the validity of magnetic resonance (MR) imaging in assessment of pulmonary arteries and ventricular functions with conotruncal anomalies in the pediatric population.
Results
Between March 2018 and December 2019, 42 patients ranging in age from 6 months to 18 years and diagnosed with conotruncal anomalies by echocardiographic examination were submitted for cardiac MRI followed by assessment of their morphological (intra- and extra-cardiac anatomy) and functional parameters. The most common conotruncal anomaly was tetralogy of Fallot which represented 45% of the cases. Cardiac magnetic resonance (CMR) compared to echocardiography showed 46% agreement in the assessment of right ventricular volumes and function. There was only 37% agreement between echocardiography and MRI in delineation of MAPCAS.
Conclusion
CMR provides a powerful tool, giving anatomical and physiological information that echocardiography and catheterization alone cannot provide in conotruncal anomalies.
Collapse
|
40
|
Schwaiger JP, Reinstadler SJ, Holzknecht M, Tiller C, Reindl M, Begle J, Lechner I, Lamina C, Mayr A, Graziadei I, Bauer A, Metzler B, Klug G. Prognostic value of depressed cardiac index after STEMI: a phase-contrast magnetic resonance study. EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE 2021; 11:53-61. [PMID: 34750623 DOI: 10.1093/ehjacc/zuab098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 05/14/2021] [Accepted: 10/18/2021] [Indexed: 11/15/2022]
Abstract
AIMS An invasively measured cardiac index (CI) of ≤2.2 L/min/m2 is one of the strongest prognostic indicators after ST-elevation myocardial infarction (STEMI), however, knowledge is mainly based on invasive evaluations performed in the pre-stent era. Velocity-encoded phase-contrast cardiac magnetic resonance (PC-CMR) allows non-invasive determination of CI. METHODS AND RESULTS In this prospective study, CMR was performed in 406 stable and contemporarily revascularized patients a median of 3 days after STEMI. Forward stroke volume was assessed at the level of the ascending aorta by PC-CMR. Left ventricular ejection fraction (LVEF) and global longitudinal strain (GLS) were determined by cine CMR. Major adverse cardiac events (MACE) were defined as the composite of death, myocardial infarction, or hospitalization for heart failure. Median CI was 2.52 L/min/m2 and 27% of patients had ≤2.2 L/min/m2. Median LVEF was 53% and median GLS was -12.2%. During a median follow-up of 14.2 [95% confidence interval (95% CI) 13.6-14.7] months, 41 patients (10.1%) experienced a MACE. A depressed CI was significantly associated with MACE after adjustment for LVEF, GLS, Thrombolysis in Myocardial Infarction (TIMI) risk score, and infarct size [hazard ratio = 3.15 (95% CI 1.53-6.47); P = 0.002] and led to significant discrimination improvement [net reclassification improvement 0.61 (95% CI 0.25-0.97); P < 0.001]. CONCLUSIONS A CI of 2.2 L/min/m2 or less as measured by PC-CMR was present in 27% of clinically stable patients after STEMI and strongly and independently predicted medium-term MACE. The prognostic value of a depressed CI was superior and incremental to LVEF, GLS, TIMI risk score, and infarct size.
Collapse
Affiliation(s)
- Johannes P Schwaiger
- Department of Internal Medicine, Academic Teaching Hospital Hall in Tirol, Milser Strasse 10, 6060 Hall in Tirol, Austria
| | - Sebastian J Reinstadler
- University Clinic of Internal Medicine III, Cardiology and Angiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria
| | - Magdalena Holzknecht
- University Clinic of Internal Medicine III, Cardiology and Angiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria
| | - Christina Tiller
- University Clinic of Internal Medicine III, Cardiology and Angiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria
| | - Martin Reindl
- University Clinic of Internal Medicine III, Cardiology and Angiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria
| | - Jana Begle
- University Clinic of Internal Medicine III, Cardiology and Angiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria
| | - Ivan Lechner
- University Clinic of Internal Medicine III, Cardiology and Angiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria
| | - Claudia Lamina
- Department of Genetics and Pharmacology, Institute of Genetic Epidemiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria
| | - Agnes Mayr
- Department of Radiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria
| | - Ivo Graziadei
- Department of Internal Medicine, Academic Teaching Hospital Hall in Tirol, Milser Strasse 10, 6060 Hall in Tirol, Austria
| | - Axel Bauer
- University Clinic of Internal Medicine III, Cardiology and Angiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria
| | - Bernhard Metzler
- University Clinic of Internal Medicine III, Cardiology and Angiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria
| | - Gert Klug
- University Clinic of Internal Medicine III, Cardiology and Angiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria
| |
Collapse
|
41
|
Kocaoglu M, Pednekar A, Tkach JA, Taylor MD. Quantitative assessment of velocity and flow using compressed SENSE in children and young adults with adequate acquired temporal resolution. J Cardiovasc Magn Reson 2021; 23:113. [PMID: 34663351 PMCID: PMC8522244 DOI: 10.1186/s12968-021-00811-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Accepted: 09/03/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Phase contrast (PC) cardiovascular magnetic resonance (CMR) imaging with parallel imaging acceleration is established and validated for measuring velocity and flow. However, additional acceleration to further shorten acquisition times would be beneficial in patients with complex vasculature who need multiple PC-CMR measurements, especially pediatric patients with higher heart rates. METHODS PC-CMR images acquired with compressed sensitivity encoding (C-SENSE) factors of 3 to 6 and standard of care PC-CMR with sensitivity encoding (SENSE) factor of 2 (S2) acquired as part of clinical CMR examinations performed between November 2020 and January 2021 were analyzed retrospectively. The velocity and flow through the ascending aorta (AAo), descending aorta (DAo), and superior vena cava (SVC) in a transverse plane at the level of pulmonary artery bifurcation were compared. Additionally, frequency power distribution and dynamic time warp distance were calculated for these acquisitions. To further validate the adequate temporal resolution requirement, patients with S2 PC-CMR in the same acquisition plane were added in frequency power distribution analysis. RESULTS Twenty-eight patients (25 males; 15.9 ± 1.9 years; body surface area (BSA) 1.7 ± 0.2 m2; heart rate 81 ± 16 bpm) underwent all five PC-CMR acquisitions during the study period. An additional 22 patients (16 males; 17.5 ± 7.7 years; BSA 1.6 ± 0.5 m2; heart rate 91 ± 16 bpm) were included for frequency power spectrum analysis. As expected, scan time decreased with increasing C-SENSE acceleration factor = 3 (37.5 ± 6.5 s, 26.4 ± 7.6%), 4 (28.1 ± 4.9 s, 44.7 ± 5.6%), 5 (21.6 ± 3.6 s, 57.6 ± 4.4%), and 6 (19.1 ± 3.2 s, 62.3 ± 4.2%) relative to SENSE = 2 (51.3 ± 10.1 s) PC-CMR acquisition. Mean peak velocity, net flow, and cardiac output were comparable (p > 0.87) between the five PC-CMR acquisitions with mean differences less than < 4%, < 2%, and < 3% respectively. All individual blood vessels showed a non-significant dependence of difference in fmax99 (< 4 Hz, p > 0.2), and dynamic time warp distance (p > 0.3) on the C-SENSE acceleration factor used. There was a strongly correlated (r = 0.74) increase in fmax99 (10.5 ± 2.2, range: 7.1-16.4 Hz) with increasing heart rate. The computed minimum required cardiac phase number was 15 ± 2.0 (range: 11-20) over the heart rate of 86 ± 15 bpm (range: 58-113 bpm). CONCLUSIONS Stroke volume, cardiac output, and mean peak velocity measurements using PC-CMR with C-SENSE of up to 6 agree with measurements by standard of care PC-CMR with SENSE = 2 and resulted in up to a 65% reduction in acquisition time. Adequate temporal sampling can be ensured by acquiring 20 cardiac phases throughout the entire cardiac cycle over a wide range of pediatric and young adult heart rates.
Collapse
Affiliation(s)
- Murat Kocaoglu
- Department of Radiology, Cincinnati Children’s Hospital Medical Center, S1.533, 3333 Burnet Ave, Cincinnati, OH 45229 USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH USA
| | - Amol Pednekar
- Department of Radiology, Cincinnati Children’s Hospital Medical Center, S1.533, 3333 Burnet Ave, Cincinnati, OH 45229 USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH USA
| | - Jean A. Tkach
- Department of Radiology, Cincinnati Children’s Hospital Medical Center, S1.533, 3333 Burnet Ave, Cincinnati, OH 45229 USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH USA
| | - Michael D. Taylor
- The Heart Institute, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH USA
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH USA
| |
Collapse
|
42
|
Latus H, Meierhofer C. Role of cardiovascular magnetic resonance in pediatric pulmonary hypertension-novel concepts and imaging biomarkers. Cardiovasc Diagn Ther 2021; 11:1057-1069. [PMID: 34527532 DOI: 10.21037/cdt-20-270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Accepted: 04/15/2020] [Indexed: 11/06/2022]
Abstract
Pulmonary hypertension (PH) in children is a heterogenous disease of the small pulmonary arteries characterized by a progressive increase in pulmonary vascular resistance. Despite adequate medical therapy, long-term pressure overload is frequently associated with a progressive course leading to right ventricular failure and ultimately death. Invasive hemodynamic assessment by cardiac catheterization is crucial for initial diagnosis, risk stratification and therapeutic strategy. Although echocardiography remains the most important imaging modality for the assessment of right ventricular function and pulmonary hemodynamics, cardiovascular magnetic resonance (CMR) has emerged as a valuable non-invasive imaging technique that enables comprehensive evaluation of biventricular performance, blood flow, morphology and the myocardial tissue. In this review, we summarize the principles and applications of CMR in the evaluation of pediatric PH patients and present an update about novel CMR based concepts and imaging biomarkers that may provide further diagnostic, therapeutic and prognostic information.
Collapse
Affiliation(s)
- Heiner Latus
- Clinic for Congenital Heart Disease and Pediatric Cardiology, German Heart Center Munich, Munich, Germany
| | - Christian Meierhofer
- Clinic for Congenital Heart Disease and Pediatric Cardiology, German Heart Center Munich, Munich, Germany
| |
Collapse
|
43
|
Scannell CM, Hasaneen H, Greil G, Hussain T, Razavi R, Lee J, Pushparajah K, Duong P, Chiribiri A. Automated Quantitative Stress Perfusion Cardiac Magnetic Resonance in Pediatric Patients. Front Pediatr 2021; 9:699497. [PMID: 34540764 PMCID: PMC8446614 DOI: 10.3389/fped.2021.699497] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Accepted: 08/05/2021] [Indexed: 11/13/2022] Open
Abstract
Background: Myocardial ischemia occurs in pediatrics, as a result of both congenital and acquired heart diseases, and can lead to further adverse cardiac events if untreated. The aim of this work is to assess the feasibility of fully automated, high resolution, quantitative stress myocardial perfusion cardiac magnetic resonance (CMR) in a cohort of pediatric patients and to evaluate its agreement with the coronary anatomical status of the patients. Methods: Fourteen pediatric patients, with 16 scans, who underwent dual-bolus stress perfusion CMR were retrospectively analyzed. All patients also had anatomical coronary assessment with either CMR, CT, or X-ray angiography. The perfusion CMR images were automatically processed and quantified using an analysis pipeline previously developed in adults. Results: Automated perfusion quantification was successful in 15/16 cases. The coronary perfusion territories supplied by vessels affected by a medium/large aneurysm or stenosis (according to the AHA guidelines), induced by Kawasaki disease, an anomalous origin, or interarterial course had significantly reduced myocardial blood flow (MBF) (median (interquartile range), 1.26 (1.05, 1.67) ml/min/g) as compared to territories supplied by unaffected coronaries [2.57 (2.02, 2.69) ml/min/g, p < 0.001] and territories supplied by vessels with a small aneurysm [2.52 (2.45, 2.83) ml/min/g, p = 0.002]. Conclusion: Automatic CMR-derived MBF quantification is feasible in pediatric patients, and the technology could be potentially used for objective non-invasive assessment of ischemia in children with congenital and acquired heart diseases.
Collapse
Affiliation(s)
- Cian M. Scannell
- School of Biomedical Engineering and Imaging Sciences, St Thomas' Hospital, King's College London, London, United Kingdom
| | - Hadeer Hasaneen
- School of Biomedical Engineering and Imaging Sciences, St Thomas' Hospital, King's College London, London, United Kingdom
| | - Gerald Greil
- Department of Pediatrics, University of Texas Southwestern Medical Center, Dallas, TX, United States
| | - Tarique Hussain
- Department of Pediatrics, University of Texas Southwestern Medical Center, Dallas, TX, United States
| | - Reza Razavi
- School of Biomedical Engineering and Imaging Sciences, St Thomas' Hospital, King's College London, London, United Kingdom
| | - Jack Lee
- School of Biomedical Engineering and Imaging Sciences, St Thomas' Hospital, King's College London, London, United Kingdom
| | - Kuberan Pushparajah
- School of Biomedical Engineering and Imaging Sciences, St Thomas' Hospital, King's College London, London, United Kingdom
| | - Phuoc Duong
- School of Biomedical Engineering and Imaging Sciences, St Thomas' Hospital, King's College London, London, United Kingdom
| | - Amedeo Chiribiri
- School of Biomedical Engineering and Imaging Sciences, St Thomas' Hospital, King's College London, London, United Kingdom
| |
Collapse
|
44
|
Hazekamp MG, Barron DJ, Dangel J, Homfray T, Jongbloed MRM, Voges I. Consensus document on optimal management of patients with common arterial trunk. Eur J Cardiothorac Surg 2021; 60:7-33. [PMID: 34017991 DOI: 10.1093/ejcts/ezaa423] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Revised: 09/18/2020] [Accepted: 09/30/2020] [Indexed: 01/12/2023] Open
Affiliation(s)
- Mark G Hazekamp
- Department of Cardiothoracic Surgery, University Hospital Leiden, Leiden, Netherlands
| | - David J Barron
- Division of Cardiovascular Surgery, The Hospital for Sick Children, Toronto, Canada
| | - Joanna Dangel
- Department of Perinatal Cardiology and Congenital Anomalies, Centre of Postgraduate Medical Education, Warsaw, Poland
| | - Tessa Homfray
- Department of Medical Genetics, Royal Brompton and Harefield hospitals NHS Trust, London, UK
| | - Monique R M Jongbloed
- Department of Anatomy and Embryology, Leiden University Medical Center, Leiden, Netherlands
| | - Inga Voges
- Department for Congenital Cardiology and Pediatric Cardiology, University Medical Center of Schleswig-Holstein, Kiel, Germany
| | | |
Collapse
|
45
|
Zou Q, Xu HY, Fu C, Zhou XY, Xu R, Yang MX, Yang ZG, Guo YK. Utility of single-shot compressed sensing cardiac magnetic resonance cine imaging for assessment of biventricular function in free-breathing and arrhythmic pediatric patients. Int J Cardiol 2021; 338:258-264. [PMID: 34181995 DOI: 10.1016/j.ijcard.2021.06.043] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Revised: 06/11/2021] [Accepted: 06/23/2021] [Indexed: 02/05/2023]
Abstract
BACKGROUND This study aimed to explore the feasibility and accuracy of single-shot compressed-sensing (CS) cardiac magnetic resonance cine technology for the assessment of biventricular function and morphology in free-breathing (FB) pediatrics, especially those with arrhythmia. METHODS Seventy consecutive pediatric participants (6.27 ± 3.8 years, range:0.5-14 years) were enrolled between August 2019 and July 2020. Single-shot CS and conventional balanced steady-state free-precession (bSSFP) cine were obtained. The total scanning time, image quality and biventricular function parameters were compared for both sequences. RESULTS Single-shot CS cine had shorter acquisition time compared with the conventional bSSFP cine (all P < 0.001). The single-shot CS cine also had fewer artifacts than conventional bSSFP cine (breath-hold (BH): 4.6 ± 0.6 vs. 4.3 ± 0.6; FB without ongoing arrhythmia: 4.5 ± 0.6 vs. 3.6 ± 0.9; FB with ongoing arrhythmia: 4.7 ± 0.5 vs. 2.6 ± 1.1; all P < 0.05). No statistical difference of left ventricular parameters and right ventricular end-systolic volume/ejection fraction were found between the single-shot CS and conventional bSSFP cine in both BH and FB without ongoing arrhythmia group. There was an excellent correlation (R2 = 0.60-0.98, all P < 0.001) and good intra-(range: R2 = 0.57-0.99, P < 0.001)/inter-observer agreements (range: R2 = 0.76-1, P < 0.001) for single-shot CS cine images in terms of biventricular function parameters. CONCLUSIONS The single-shot CS cine can significantly reduce the image acquisition time, offering reliable quantification of biventricular function in free breathing condition for arrhythmic patients.
Collapse
Affiliation(s)
- Qing Zou
- Department of Radiology, West China Second University Hospital, Sichuan University, 20# Section 3 South Renmin Road, Chengdu, Sichuan 610041, China; Department of Radiology, Deyang People's Hospital, 173# Section 3 Tai Shan Road, Deyang, Sichuan 618400, China
| | - Hua-Yan Xu
- Department of Radiology, West China Second University Hospital, Sichuan University, 20# Section 3 South Renmin Road, Chengdu, Sichuan 610041, China
| | - Chuan Fu
- Department of Radiology, West China Second University Hospital, Sichuan University, 20# Section 3 South Renmin Road, Chengdu, Sichuan 610041, China
| | - Xiao-Yue Zhou
- MR Collaboration, Siemens Healthineers Ltd., Shanghai, China
| | - Rong Xu
- Department of Radiology, West China Second University Hospital, Sichuan University, 20# Section 3 South Renmin Road, Chengdu, Sichuan 610041, China
| | - Meng-Xi Yang
- Key Laboratory of Birth Defects and Related Diseases of Women and Children of Ministry of Education, West China Second University Hospital, Sichuan University, Chengdu 610041, China
| | - Zhi-Gang Yang
- Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041, China
| | - Ying-Kun Guo
- Department of Radiology, West China Second University Hospital, Sichuan University, 20# Section 3 South Renmin Road, Chengdu, Sichuan 610041, China.
| |
Collapse
|
46
|
Pushparajah K. Non-invasive Imaging in the Evaluation of Cardiac Shunts for Interventional Closure. Front Cardiovasc Med 2021; 8:651726. [PMID: 34222361 PMCID: PMC8253251 DOI: 10.3389/fcvm.2021.651726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2021] [Accepted: 04/08/2021] [Indexed: 11/13/2022] Open
Abstract
Multimodality imaging provides important information to guide patient selection and pre-procedural decision making for shunt lesions in CHD. While echocardiography, CT, and CMR are well-established, 3D printing and now virtual reality imaging are beginning to show promise.
Collapse
Affiliation(s)
- Kuberan Pushparajah
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, United Kingdom.,Department of Paediatric Cardiology, Evelina London Children's Hospital, London, United Kingdom
| |
Collapse
|
47
|
|
48
|
Tretter JT, Jacobs JP. Global leadership in paediatric and congenital cardiac care: "Humility in Leadership - an interview with Katarina Hanséus, MD, PhD, President of the Association for European Paediatric and Congenital Cardiology (AEPC)". Cardiol Young 2021; 31:689-695. [PMID: 34011430 DOI: 10.1017/s1047951121001669] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Dr. Katarina Hanséus is the focus of our fourth in a series of interviews in Cardiology in the Young entitled, "Global Leadership in Paediatric and Congenital Cardiac Care". Dr. Hanséus was born in Malmö, Sweden. She attended undergraduate school in her home town in Malmö, Sweden, graduating in 1974. Dr. Hanséus then went on to complete medical school at University of Lund in Lund, Sweden, graduating in 1980, where additionally she completed a Doctoral Dissertation in the evaluation of cardiac function and chamber size in children using Doppler and cross-sectional echocardiography. Under the Swedish Board of National Welfare, Dr. Hanséus completed her authorisation as a paediatrician in 1986, followed by her authorisation as a paediatric cardiologist in 1988, at University of Lund. She was appointed head of Paediatric Cardiology in 2000 at the Children's Heart Center, Skane University Hospital, Lund, Sweden. The programme at Lund serves as one of the two national referral centres for comprehensive paediatric and congenital cardiac care, including paediatric cardiac surgery, in Sweden. From 2006 to 2013, she served as the clinical and administrative head of the Department of Neonatology, Paediatric Surgery, Paediatric Intensive Care, Paediatric Cardiology, and Paediatric Cardiac Surgery, returning as the head of Paediatric Cardiology in 2013, for which she currently holds the position.Dr. Hanséus is a recognised leader in the field of Paediatric Cardiology and has been involved in leadership within the Swedish Pediatric Society, the Swedish Association for Pediatric Cardiology, and the Association for European Paediatric and Congenital Cardiology throughout her career. Within the Association for European Paediatric and Congenital Cardiology, she served as the Secretary General from 2011 to 2016, the President Elect in 2018, and is the current President serving from 2019 until 2022. This article presents our interview with Dr. Hanséus, an interview that covers her experience as a leader in the field of Paediatric Cardiology, including the history and goals of the Association for European Paediatric and Congenital Cardiology, and her role and vision as their current President.
Collapse
Affiliation(s)
- Justin T Tretter
- The Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Jeffrey P Jacobs
- Congenital Heart Center, UF Health Shands Children's Hospital, Gainesville, Florida, USA
- Division of Cardiovascular Surgery, Department of Surgery, University of Florida, Gainesville, Florida, USA
- Cardiology in the Young, Cambridge University Press, Cambridge, UK
| |
Collapse
|
49
|
Sun L, Lee FT, van Amerom JFP, Freud L, Jaeggi E, Macgowan CK, Seed M. Update on fetal cardiovascular magnetic resonance and utility in congenital heart disease. JOURNAL OF CONGENITAL CARDIOLOGY 2021. [DOI: 10.1186/s40949-021-00059-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
Congenital heart disease (CHD) is the most common birth defect, affecting approximately eight per thousand newborns. Between one and two neonates per thousand have congenital cardiac lesions that require immediate post-natal treatment to stabilize the circulation, and the management of these patients in particular has been greatly enhanced by prenatal detection. The antenatal diagnosis of CHD has been made possible through the development of fetal echocardiography, which provides excellent visualization of cardiac anatomy and physiology and is widely available. However, late gestational fetal echocardiographic imaging can be hampered by suboptimal sonographic windows, particularly in the setting of oligohydramnios or adverse maternal body habitus.
Main body
Recent advances in fetal cardiovascular magnetic resonance (CMR) technology now provide a feasible alternative that could be helpful when echocardiography is inconclusive or limited. Fetal CMR has also been used to study fetal circulatory physiology in human fetuses with CHD, providing new insights into how these common anatomical abnormalities impact the distribution of blood flow and oxygen across the fetal circulation. In combination with conventional fetal and neonatal magnetic resonance imaging (MRI) techniques, fetal CMR can be used to explore the relationship between abnormal cardiovascular physiology and fetal development. Similarly, fetal CMR has been successfully applied in large animal models of the human fetal circulation, aiding in the evaluation of experimental interventions aimed at improving in utero development. With the advent of accelerated image acquisition techniques, post-processing approaches to correcting motion artifacts and commercial MRI compatible cardiotocography units for acquiring gated fetal cardiac imaging, an increasing number of CMR methods including angiography, ventricular volumetry, and the quantification of vessel blood flow and oxygen content are now possible.
Conclusion
Fetal CMR has reached an exciting stage whereby it may now be used to enhance the assessment of cardiac morphology and fetal hemodynamics in the setting of prenatal CHD.
Collapse
|
50
|
Reduced scan time and superior image quality with 3D flow MRI compared to 4D flow MRI for hemodynamic evaluation of the Fontan pathway. Sci Rep 2021; 11:6507. [PMID: 33753790 PMCID: PMC7985309 DOI: 10.1038/s41598-021-85936-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Accepted: 03/03/2021] [Indexed: 12/14/2022] Open
Abstract
Long scan times prohibit a widespread clinical applicability of 4D flow MRI in Fontan patients. As pulsatility in the Fontan pathway is minimal during the cardiac cycle, acquiring non-ECG gated 3D flow MRI may result in a reduction of scan time while accurately obtaining time-averaged clinical parameters in comparison with 2D and 4D flow MRI. Thirty-two Fontan patients prospectively underwent 2D (reference), 3D and 4D flow MRI of the Fontan pathway. Multiple clinical parameters were assessed from time-averaged flow rates, including the right-to-left pulmonary flow distribution (main endpoint) and systemic-to-pulmonary collateral flow (SPCF). A ten-fold reduction in scan time was achieved [4D flow 15.9 min (SD 2.7 min) and 3D flow 1.6 min (SD 7.8 s), p < 0.001] with a superior signal-to-noise ratio [mean ratio of SNRs 1.7 (0.8), p < 0.001] and vessel sharpness [mean ratio 1.2 (0.4), p = 0.01] with 3D flow. Compared to 2D flow, good–excellent agreement was shown for mean flow rates (ICC 0.82–0.96) and right-to-left pulmonary flow distribution (ICC 0.97). SPCF derived from 3D flow showed good agreement with that from 4D flow (ICC 0.86). 3D flow MRI allows for obtaining time-averaged flow rates and derived clinical parameters in the Fontan pathway with good–excellent agreement with 2D and 4D flow, but with a tenfold reduction in scan time and significantly improved image quality compared to 4D flow.
Collapse
|