1
|
Fung AA, Fung AH, Li Z, Shi L. Single-Frame Vignetting Correction for Post-Stitched-Tile Imaging Using VISTAmap. NANOMATERIALS (BASEL, SWITZERLAND) 2025; 15:563. [PMID: 40214608 PMCID: PMC11990085 DOI: 10.3390/nano15070563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/12/2025] [Revised: 04/03/2025] [Accepted: 04/05/2025] [Indexed: 04/14/2025]
Abstract
Stimulated Raman Scattering (SRS) nanoscopy imaging offers unprecedented insights into tissue molecular architecture but often requires stitching multiple high-resolution tiles to capture large fields of view. This process is time-consuming and frequently introduces vignetting artifacts-grid-like intensity fluctuations that degrade image quality and hinder downstream quantitative analyses and processing such as super-resolution deconvolution. We present VIgnetted Stitched-Tile Adjustment using Morphological Adaptive Processing (VISTAmap), a simple tool that corrects these shading artifacts directly on the final stitched image. VISTAmap automatically detects the tile grid configuration by analyzing intensity frequency variations and then applies sequential morphological operations to homogenize the image. In contrast to conventional approaches that require increased tile overlap or pre-acquisition background sampling, VISTAmap offers a pragmatic, post-processing solution without the need for separate individual tile images. This work addresses pressing concerns by delivering a robust, efficient strategy for enhancing mosaic image uniformity in modern nanoscopy, where the smallest details make tremendous impacts.
Collapse
Affiliation(s)
- Anthony A. Fung
- Department of Biomedical Engineering, Yale University, New Haven, CT 06520, USA
| | - Ashley H. Fung
- Department of Medicine, Yale School of Medicine, New Haven, CT 06520, USA;
| | - Zhi Li
- Shu Chien-Gene Lay Department of Bioengineering, University of California San Diego, La Jolla, CA 92093, USA; (Z.L.); (L.S.)
| | - Lingyan Shi
- Shu Chien-Gene Lay Department of Bioengineering, University of California San Diego, La Jolla, CA 92093, USA; (Z.L.); (L.S.)
| |
Collapse
|
2
|
Behr M, Alizadeh L, Buckner-Baiamonte L, Roberts B, Sholl AB, Brown JQ. Structured illumination microscopy for cancer identification in diagnostic breast biopsies. PLoS One 2024; 19:e0302600. [PMID: 38722960 PMCID: PMC11081287 DOI: 10.1371/journal.pone.0302600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Accepted: 04/08/2024] [Indexed: 05/13/2024] Open
Abstract
Breast cancer is the second most common cancer diagnosed in women in the US with almost 280,000 new cases anticipated in 2023. Currently, on-site pathology for location guidance is not available during the collection of breast biopsies or during surgical intervention procedures. This shortcoming contributes to repeat biopsy and re-excision procedures, increasing the cost and patient discomfort during the cancer management process. Both procedures could benefit from on-site feedback, but current clinical on-site evaluation techniques are not commonly used on breast tissue because they are destructive and inaccurate. Ex-vivo microscopy is an emerging field aimed at creating histology-analogous images from non- or minimally-processed tissues, and is a promising tool for addressing this pain point in clinical cancer management. We investigated the ability structured illumination microscopy (SIM) to generate images from freshly-obtained breast tissues for structure identification and cancer identification at a speed compatible with potential on-site clinical implementation. We imaged 47 biopsies from patients undergoing a guided breast biopsy procedure using a customized SIM system and a dual-color fluorescent hematoxylin & eosin (H&E) analog. These biopsies had an average size of 0.92 cm2 (minimum 0.1, maximum 4.2) and had an average imaging time of 7:29 (minimum 0:22, maximum 37:44). After imaging, breast biopsies were submitted for standard histopathological processing and review. A board-certified pathologist returned a binary diagnostic accuracy of 96% when compared to diagnoses from gold-standard histology slides, and key tissue features including stroma, vessels, ducts, and lobules were identified from the resulting images.
Collapse
Affiliation(s)
- Madeline Behr
- Department of Biomedical Engineering, Tulane University, New Orleans, LA, United States of America
| | - Layla Alizadeh
- Department of Pathology, Ochsner Medical Center, New Orleans, LA, United States of America
| | | | - Brett Roberts
- Department of Radiology, Ochsner Medical Center, New Orleans, LA, United States of America
| | - Andrew B. Sholl
- Department of Pathology, Touro Infirmary, New Orleans, LA, United States of America
| | - J. Quincy Brown
- Department of Biomedical Engineering, Tulane University, New Orleans, LA, United States of America
| |
Collapse
|
3
|
Lee M, Jeong H, Lee C, Lee MJ, Delmo BR, Heo WD, Shin JH, Park Y. High-resolution assessment of multidimensional cellular mechanics using label-free refractive-index traction force microscopy. Commun Biol 2024; 7:115. [PMID: 38245624 PMCID: PMC10799850 DOI: 10.1038/s42003-024-05788-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Accepted: 01/03/2024] [Indexed: 01/22/2024] Open
Abstract
A critical requirement for studying cell mechanics is three-dimensional assessment of cellular shapes and forces with high spatiotemporal resolution. Traction force microscopy with fluorescence imaging enables the measurement of cellular forces, but it is limited by photobleaching and a slow acquisition speed. Here, we present refractive-index traction force microscopy (RI-TFM), which simultaneously quantifies the volumetric morphology and traction force of cells using a high-speed illumination scheme with 0.5-Hz temporal resolution. Without labelling, our method enables quantitative analyses of dry-mass distributions and shear (in-plane) and normal (out-of-plane) tractions of single cells on the extracellular matrix. When combined with a constrained total variation-based deconvolution algorithm, it provides 0.55-Pa shear and 1.59-Pa normal traction sensitivity for a 1-kPa hydrogel substrate. We demonstrate its utility by assessing the effects of compromised intracellular stress and capturing the rapid dynamics of cellular junction formation in the spatiotemporal changes in non-planar traction components.
Collapse
Affiliation(s)
- Moosung Lee
- Department of Physics, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, South Korea
- KAIST Institute for Health Science and Technology, KAIST, Daejeon, 34141, South Korea
- Institute for Functional Matter and Quantum Technologies, Universität Stuttgart, 70569, Stuttgart, Germany
| | - Hyuntae Jeong
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, South Korea
| | - Chaeyeon Lee
- Department of Biological Sciences, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, South Korea
| | - Mahn Jae Lee
- KAIST Institute for Health Science and Technology, KAIST, Daejeon, 34141, South Korea
- Graduate School of Medical Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, South Korea
| | - Benedict Reve Delmo
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, South Korea
| | - Won Do Heo
- Department of Biological Sciences, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, South Korea.
- KAIST Institute for the BioCentury (KIB), KAIST, Jaejeo, Daejeon, 34141, South Korea.
| | - Jennifer H Shin
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, South Korea.
| | - YongKeun Park
- Department of Physics, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, South Korea.
- KAIST Institute for Health Science and Technology, KAIST, Daejeon, 34141, South Korea.
- Tomocube Inc., Daejeon, 34109, South Korea.
| |
Collapse
|
4
|
Paul TC, Hagen G. Improving optical sectioning with spinning disk structured illumination microscopy. OPTICS EXPRESS 2023; 31:38831-38839. [PMID: 38017977 DOI: 10.1364/oe.499277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Accepted: 10/04/2023] [Indexed: 11/30/2023]
Abstract
A new fluorescence microscopy technique for optical sectioning was investigated. This technique combined Spinning Disk microscopy (SD) with Structured Illumination Microscopy (SIM), resulting in more background removal than either method. Spinning Disk Structured Illumination Microscopy (SD-SIM) resulted in higher signal-to-background ratios. The method detected and quantified a dendritic spine neck that was impossible to detect with either SIM or SD alone.
Collapse
|
5
|
Paul TC, Johnson KA, Hagen GM. Super-Resolution Imaging of Neuronal Structures with Structured Illumination Microscopy. Bioengineering (Basel) 2023; 10:1081. [PMID: 37760183 PMCID: PMC10525192 DOI: 10.3390/bioengineering10091081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2023] [Accepted: 09/09/2023] [Indexed: 09/29/2023] Open
Abstract
Super-resolution structured illumination microscopy (SR-SIM) is an optical fluorescence microscopy method which is suitable for imaging a wide variety of cells and tissues in biological and biomedical research. Typically, SIM methods use high spatial frequency illumination patterns generated by laser interference. This approach provides high resolution but is limited to thin samples such as cultured cells. Using a different strategy for processing raw data and coarser illumination patterns, we imaged through a 150-micrometer-thick coronal section of a mouse brain expressing GFP in a subset of neurons. The resolution reached 144 nm, an improvement of 1.7-fold beyond conventional widefield imaging.
Collapse
Affiliation(s)
| | | | - Guy M. Hagen
- UCCS BioFrontiers Center, University of Colorado Colorado Springs, 1420 Austin Bluffs Parkway, Colorado Springs, CO 80918, USA; (T.C.P.); (K.A.J.)
| |
Collapse
|
6
|
Paul TC, Johnson KA, Hagen GM. Super-resolution imaging of neuronal structure with structured illumination microscopy. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.05.26.542523. [PMID: 37292949 PMCID: PMC10245995 DOI: 10.1101/2023.05.26.542523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Super-resolution structured illumination microscopy (SR-SIM) is a method in optical fluorescence microscopy which is suitable for imaging a wide variety of cells and tissues in biological and biomedical research. Typically, SIM methods use high spatial frequency illumination patterns generated by laser interference. This approach provides high resolution but is limited to thin samples such as cultured cells. Using a different strategy for processing the raw data and coarser illumination patterns, we imaged through a 150 µm thick coronal section of a mouse brain expressing GFP in a subset of neurons. The resolution reached 144 nm, an improvement of 1.7 fold beyond conventional widefield imaging.
Collapse
Affiliation(s)
- Tristan C. Paul
- UCCS BioFrontiers Center, University of Colorado Colorado Springs, 1420 Austin Bluffs Parkway, Colorado Springs, Colorado, 80918
| | - Karl A. Johnson
- UCCS BioFrontiers Center, University of Colorado Colorado Springs, 1420 Austin Bluffs Parkway, Colorado Springs, Colorado, 80918
| | - Guy M. Hagen
- UCCS BioFrontiers Center, University of Colorado Colorado Springs, 1420 Austin Bluffs Parkway, Colorado Springs, Colorado, 80918
| |
Collapse
|
7
|
Rapid On-Site Microscopy and Mapping of Diagnostic Biopsies for See-And-Treat Guidance of Localized Prostate Cancer Therapy. Cancers (Basel) 2023; 15:cancers15030792. [PMID: 36765751 PMCID: PMC9913800 DOI: 10.3390/cancers15030792] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 01/25/2023] [Accepted: 01/25/2023] [Indexed: 01/31/2023] Open
Abstract
Prostate cancer continues to be the most diagnosed non-skin malignancy in men. While up to one in eight men will be diagnosed in their lifetimes, most diagnoses are not fatal. Better lesion location accuracy combined with emerging localized treatment methods are increasingly being utilized as a treatment option to preserve healthy function in eligible patients. In locating lesions which are generally <2cc within a prostate (average size 45cc), small variance in MRI-determined boundaries, tumoral heterogeneity, patient characteristics including location of lesion and prostatic calcifications, and patient motion during the procedure can inhibit accurate sampling for diagnosis. The locations of biopsies are recorded and are then fully processed by histology and diagnosed via pathology, often days to weeks later. Utilization of real-time feedback could improve accuracy, potentially prevent repeat procedures, and allow patients to undergo treatment of clinically localized disease at earlier stages. Unfortunately, there is currently no reliable real-time feedback process for confirming diagnosis of biopsy samples. We examined the feasibility of implementing structured illumination microscopy (SIM) as a method for on-site diagnostic biopsy imaging to potentially combine the diagnostic and treatment appointments for prostate cancer patients, or to confirm tumoral margins for localized ablation procedures. We imaged biopsies from 39 patients undergoing image-guided diagnostic biopsy using a customized SIM system and a dual-color fluorescent hematoxylin & eosin (H&E) analog. The biopsy images had an average size of 342 megapixels (minimum 78.1, maximum 842) and an average imaging duration of 145 s (minimum 56, maximum 322). Comparison of urologist's suspicion of malignancy based on MRI, to pathologist diagnosis of biopsy images obtained in real time, reveals that real-time biopsy imaging could significantly improve confirmation of malignancy or tumoral margins over medical imaging alone.
Collapse
|
8
|
Zhao J, Han Z, Ma Y, Liu H, Yang T. Research progress in digital pathology: A bibliometric and visual analysis based on Web of Science. Pathol Res Pract 2022; 240:154171. [DOI: 10.1016/j.prp.2022.154171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Revised: 10/12/2022] [Accepted: 10/13/2022] [Indexed: 11/05/2022]
|
9
|
Flexible Multiplane Structured Illumination Microscope with a Four-Camera Detector. PHOTONICS 2022; 9. [PMID: 35966275 PMCID: PMC9373035 DOI: 10.3390/photonics9070501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
Abstract
Fluorescence microscopy provides an unparalleled tool for imaging biological samples. However, producing high-quality volumetric images quickly and without excessive complexity remains a challenge. Here, we demonstrate a four-camera structured illumination microscope (SIM) capable of simultaneously imaging multiple focal planes, allowing for the capture of 3D fluorescent images without any axial movement of the sample. This setup allows for the acquisition of many different 3D imaging modes, including 3D time lapses, high-axial-resolution 3D images, and large 3D mosaics. We imaged mitochondrial motions in live cells, neuronal structure in Drosophila larvae, and imaged up to 130 µm deep into mouse brain tissue. After SIM processing, the resolution measured using one of the four cameras improved from 357 nm to 253 nm when using a 30×/1.05 NA objective.
Collapse
|
10
|
Villegas-Hernández LE, Dubey V, Nystad M, Tinguely JC, Coucheron DA, Dullo FT, Priyadarshi A, Acuña S, Ahmad A, Mateos JM, Barmettler G, Ziegler U, Birgisdottir ÅB, Hovd AMK, Fenton KA, Acharya G, Agarwal K, Ahluwalia BS. Chip-based multimodal super-resolution microscopy for histological investigations of cryopreserved tissue sections. LIGHT, SCIENCE & APPLICATIONS 2022; 11:43. [PMID: 35210400 PMCID: PMC8873254 DOI: 10.1038/s41377-022-00731-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/22/2021] [Revised: 01/20/2022] [Accepted: 02/02/2022] [Indexed: 06/14/2023]
Abstract
Histology involves the observation of structural features in tissues using a microscope. While diffraction-limited optical microscopes are commonly used in histological investigations, their resolving capabilities are insufficient to visualize details at subcellular level. Although a novel set of super-resolution optical microscopy techniques can fulfill the resolution demands in such cases, the system complexity, high operating cost, lack of multi-modality, and low-throughput imaging of these methods limit their wide adoption for histological analysis. In this study, we introduce the photonic chip as a feasible high-throughput microscopy platform for super-resolution imaging of histological samples. Using cryopreserved ultrathin tissue sections of human placenta, mouse kidney, pig heart, and zebrafish eye retina prepared by the Tokuyasu method, we demonstrate diverse imaging capabilities of the photonic chip including total internal reflection fluorescence microscopy, intensity fluctuation-based optical nanoscopy, single-molecule localization microscopy, and correlative light-electron microscopy. Our results validate the photonic chip as a feasible imaging platform for tissue sections and pave the way for the adoption of super-resolution high-throughput multimodal analysis of cryopreserved tissue samples both in research and clinical settings.
Collapse
Affiliation(s)
- Luis E Villegas-Hernández
- Department of Physics and Technology, UiT The Arctic University of Norway, Klokkargårdsbakken N-9019, Tromsø, Norway
| | - Vishesh Dubey
- Department of Physics and Technology, UiT The Arctic University of Norway, Klokkargårdsbakken N-9019, Tromsø, Norway
| | - Mona Nystad
- Department of Clinical Medicine, Women's Health and Perinatology Research Group, UiT The Arctic University of Norway, Tromsø, Norway
- Department of Obstetrics and Gynecology, University Hospital of North Norway, Tromsø, Norway
| | - Jean-Claude Tinguely
- Department of Physics and Technology, UiT The Arctic University of Norway, Klokkargårdsbakken N-9019, Tromsø, Norway
| | - David A Coucheron
- Department of Physics and Technology, UiT The Arctic University of Norway, Klokkargårdsbakken N-9019, Tromsø, Norway
| | - Firehun T Dullo
- Department of Physics and Technology, UiT The Arctic University of Norway, Klokkargårdsbakken N-9019, Tromsø, Norway
| | - Anish Priyadarshi
- Department of Physics and Technology, UiT The Arctic University of Norway, Klokkargårdsbakken N-9019, Tromsø, Norway
| | - Sebastian Acuña
- Department of Physics and Technology, UiT The Arctic University of Norway, Klokkargårdsbakken N-9019, Tromsø, Norway
| | - Azeem Ahmad
- Department of Physics and Technology, UiT The Arctic University of Norway, Klokkargårdsbakken N-9019, Tromsø, Norway
| | - José M Mateos
- Center for Microscopy and Image Analysis, University of Zurich, Zürich, Switzerland
| | - Gery Barmettler
- Center for Microscopy and Image Analysis, University of Zurich, Zürich, Switzerland
| | - Urs Ziegler
- Center for Microscopy and Image Analysis, University of Zurich, Zürich, Switzerland
| | - Åsa Birna Birgisdottir
- Division of Cardiothoracic and Respiratory Medicine, University Hospital of North Norway, Tromsø, Norway
- Department of Clinical Medicine, Clinical Cardiovascular Research Group, UiT The Arctic University of Norway, Tromsø, Norway
| | - Aud-Malin Karlsson Hovd
- Department of Medical Biology, RNA and Molecular Pathology Research Group, UiT The Arctic University of Norway, Tromsø, Norway
| | - Kristin Andreassen Fenton
- Department of Medical Biology, RNA and Molecular Pathology Research Group, UiT The Arctic University of Norway, Tromsø, Norway
| | - Ganesh Acharya
- Department of Clinical Medicine, Women's Health and Perinatology Research Group, UiT The Arctic University of Norway, Tromsø, Norway
- Division of Obstetrics and Gynecology, Department of Clinical Science, Intervention and Technology, Karolinska Institute, Stockholm, Sweden
| | - Krishna Agarwal
- Department of Physics and Technology, UiT The Arctic University of Norway, Klokkargårdsbakken N-9019, Tromsø, Norway
| | - Balpreet Singh Ahluwalia
- Department of Physics and Technology, UiT The Arctic University of Norway, Klokkargårdsbakken N-9019, Tromsø, Norway.
- Division of Obstetrics and Gynecology, Department of Clinical Science, Intervention and Technology, Karolinska Institute, Stockholm, Sweden.
| |
Collapse
|
11
|
Wen G, Li S, Wang L, Chen X, Sun Z, Liang Y, Jin X, Xing Y, Jiu Y, Tang Y, Li H. High-fidelity structured illumination microscopy by point-spread-function engineering. LIGHT, SCIENCE & APPLICATIONS 2021; 10:70. [PMID: 33795640 PMCID: PMC8016956 DOI: 10.1038/s41377-021-00513-w] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 03/13/2021] [Accepted: 03/14/2021] [Indexed: 05/28/2023]
Abstract
Structured illumination microscopy (SIM) has become a widely used tool for insight into biomedical challenges due to its rapid, long-term, and super-resolution (SR) imaging. However, artifacts that often appear in SIM images have long brought into question its fidelity, and might cause misinterpretation of biological structures. We present HiFi-SIM, a high-fidelity SIM reconstruction algorithm, by engineering the effective point spread function (PSF) into an ideal form. HiFi-SIM can effectively reduce commonly seen artifacts without loss of fine structures and improve the axial sectioning for samples with strong background. In particular, HiFi-SIM is not sensitive to the commonly used PSF and reconstruction parameters; hence, it lowers the requirements for dedicated PSF calibration and complicated parameter adjustment, thus promoting SIM as a daily imaging tool.
Collapse
Affiliation(s)
- Gang Wen
- Jiangsu Key Laboratory of Medical Optics, CAS Center for Excellence in Molecular Cell Science, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, 215163, China
- Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
| | - Simin Li
- Jiangsu Key Laboratory of Medical Optics, CAS Center for Excellence in Molecular Cell Science, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, 215163, China
| | - Linbo Wang
- Jiangsu Key Laboratory of Medical Optics, CAS Center for Excellence in Molecular Cell Science, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, 215163, China
| | - Xiaohu Chen
- Jiangsu Key Laboratory of Medical Optics, CAS Center for Excellence in Molecular Cell Science, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, 215163, China
| | - Zhenglong Sun
- Jiangsu Key Laboratory of Medical Optics, CAS Center for Excellence in Molecular Cell Science, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, 215163, China
| | - Yong Liang
- Jiangsu Key Laboratory of Medical Optics, CAS Center for Excellence in Molecular Cell Science, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, 215163, China
| | - Xin Jin
- Jiangsu Key Laboratory of Medical Optics, CAS Center for Excellence in Molecular Cell Science, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, 215163, China
| | - Yifan Xing
- The Center for Microbes, Development and Health, Key Laboratory of Molecular Virology and Immunology, Institute Pasteur of Shanghai, Chinese Academy of Sciences, Shanghai, 200031, China
| | - Yaming Jiu
- The Center for Microbes, Development and Health, Key Laboratory of Molecular Virology and Immunology, Institute Pasteur of Shanghai, Chinese Academy of Sciences, Shanghai, 200031, China
| | - Yuguo Tang
- Jiangsu Key Laboratory of Medical Optics, CAS Center for Excellence in Molecular Cell Science, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, 215163, China.
| | - Hui Li
- Jiangsu Key Laboratory of Medical Optics, CAS Center for Excellence in Molecular Cell Science, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, 215163, China.
| |
Collapse
|
12
|
Johnson KA, Hagen GM. Artifact-free whole-slide imaging with structured illumination microscopy and Bayesian image reconstruction. Gigascience 2020; 9:giaa035. [PMID: 32285910 PMCID: PMC7155289 DOI: 10.1093/gigascience/giaa035] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Revised: 12/06/2019] [Accepted: 03/24/2020] [Indexed: 01/19/2023] Open
Abstract
BACKGROUND Structured illumination microscopy (SIM) is a method that can be used to image biological samples and can achieve both optical sectioning and super-resolution effects. Optimization of the imaging set-up and data-processing methods results in high-quality images without artifacts due to mosaicking or due to the use of SIM methods. Reconstruction methods based on Bayesian estimation can be used to produce images with a resolution beyond that dictated by the optical system. FINDINGS Five complete datasets are presented including large panoramic SIM images of human tissues in pathophysiological conditions. Cancers of the prostate, skin, ovary, and breast, as well as tuberculosis of the lung, were imaged using SIM. The samples are available commercially and are standard histological preparations stained with hematoxylin-eosin. CONCLUSION The use of fluorescence microscopy is increasing in histopathology. There is a need for methods that reduce artifacts caused by the use of image-stitching methods or optical sectioning methods such as SIM. Stitched SIM images produce results that may be useful for intraoperative histology. Releasing high-quality, full-slide images and related data will aid researchers in furthering the field of fluorescent histopathology.
Collapse
Affiliation(s)
- Karl A Johnson
- UCCS BioFrontiers Center, University of Colorado at Colorado Springs, 1420 Austin Bluffs Parkway, Colorado Springs, CO 80918, USA
| | - Guy M Hagen
- UCCS BioFrontiers Center, University of Colorado at Colorado Springs, 1420 Austin Bluffs Parkway, Colorado Springs, CO 80918, USA
| |
Collapse
|