1
|
Malaisrie SC, Mumtaz MA, Barnhart GR, Chitwood R, Ryan WH, Accola KD, Patel HJ, Woo YJ, Dewey TM, Koulogiannis K, Dorsey MP, Grossi EA. Midterm outcomes of aortic valve replacement using a rapid-deployment valve for aortic stenosis: TRANSFORM trial. JTCVS OPEN 2024; 17:55-63. [PMID: 38420551 PMCID: PMC10897657 DOI: 10.1016/j.xjon.2023.10.034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 10/12/2023] [Accepted: 10/26/2023] [Indexed: 03/02/2024]
Abstract
Background The use of rapid-deployment valves (RDVs) has been shown to reduce the operative time for surgical aortic valve replacement (AVR). Long-term core laboratory-adjudicated data are scarce, however. Here we report final 7-year data on RDV use. Methods TRANSFORM was a prospective, nonrandomized, multicenter, single-arm trial implanting a stented bovine pericardial valve with an incorporated balloon-expandable sealing frame. A prior published 1-year analysis included 839 patients from 29 centers. An additional 46 patients were enrolled and implanted, for a total of 885 patients. Annual clinical and core laboratory-adjudicated echocardiographic outcomes were collected through 8 years. Primary endpoints were structural valve deterioration (SVD), all-cause reintervention, all-cause valve explantation, and all-cause mortality. Secondary endpoints included hemodynamic performance assessed by echocardiography. The mean duration of follow-up was 5.0 ± 2.0 years. Results The mean patient age was 73.3 ± 8.2 years. Isolated AVR was performed in 62.1% of the patients, and AVR with concomitant procedures was performed in 37.9%. Freedom from all-cause mortality at 7 years was 76.0% for isolated AVR and 68.2% for concomitant AVR. Freedom from SVD, all-cause reintervention, and valve explantation at 7 years was 97.5%, 95.7%, and 97.8%, respectively. The mean gradient and effective orifice area at 7 years were 11.1 ± 5.3 mm Hg and 1.6 ± 0.3 cm2, respectively. Paravalvular leak at 7 years was none/trace in 88.6% and mild in 11.4%. In patients undergoing isolated AVR, the cumulative probability of pacemaker implantation was 13.9% at 30 days, 15.5% at 1 year, and 21.8% at 7 years. Conclusions AVR for aortic stenosis using an RDV is associated with low rates of late adverse events. This surgical pericardial tissue platform provides excellent and stable hemodynamic performance through 7 years.
Collapse
Affiliation(s)
| | - Mubashir A Mumtaz
- Department of Cardiovascular and Thoracic Surgery, University of Pittsburgh Medical Center Harrisburg, Harrisburg, Pa
| | - Glenn R Barnhart
- Structural Heart Program, Swedish Heart and Vascular Institute, Seattle, Wash
| | - Randolph Chitwood
- Department of Cardiovascular Sciences, East Carolina University, Greenville, NC
| | - William H Ryan
- Cardiac Surgery Specialists, Baylor Plano Heart Hospital, Plano, Tex
| | - Kevin D Accola
- Florida Hospital Cardiovascular Institute, Florida Hospital Orlando, Orlando, Fla
| | - Himanshu J Patel
- Department of Cardiac Surgery, University of Michigan, Ann Arbor, Mich
| | - Y Joseph Woo
- Department of Cardiothoracic Surgery, Stanford University, Palo Alto, Calif
| | | | | | - Michael P Dorsey
- Department of Cardiothoracic Surgery, New York University Langone Medical Center, New York, NY
| | - Eugene A Grossi
- Department of Cardiothoracic Surgery, New York University Langone Medical Center, New York, NY
| |
Collapse
|
2
|
Januszek R, Balan R. Predictors of New and Persistent New Left Bundle Branch Block One Year after the Implantation of a Sutureless and Rapid-Deployment Aortic Valve Prosthesis. Diseases 2023; 11:100. [PMID: 37606471 PMCID: PMC10443328 DOI: 10.3390/diseases11030100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2023] [Revised: 07/20/2023] [Accepted: 07/27/2023] [Indexed: 08/23/2023] Open
Abstract
INTRODUCTION Conduction disorders following aortic valve replacement therapy (AVR), either surgical or percutaneous, are related to a higher risk of complete atrioventricular block and permanent pacemaker implantation (PPI). AIM The objective of this study was to assess risk factors regarding the incidence of new postoperative and persistent new left bundle branch block (LBBB) 1 year after the implantation of a sutureless/rapid-deployment (SURD) aortic valve prosthesis. MATERIAL AND METHODS The current study included 200 consecutive patients treated with isolated or concomitant AVR between May 2014 and May 2017 at the Department of Cardiac Surgery in Pasawa with SURD aortic valve EDWARDS INTUITY EliteTM implantation. The patients were divided according to the presence of new postoperative LBBB (67 patients, 33.5%) and persistent new LBBB 1 year after AVR (35 patients, 17.5%). A comparative analysis was performed between patients with and without new LBBB after AVR and those with and without persistent LBBB 1 year after AVR. Univariate and multivariate regression analyses were conducted to extract the risk factors of LBBB occurrence. RESULTS Among the risk factors for the lack of new LBBB development after AVR, Euroscore II (p < 0.001) was found, while for the occurrence of persistent new LBBB 1 year after AVR, atrial fibrillation (p = 0.001), length of hospital stay (p = 0.001) and body mass index (p = 0.004) were noted. CONCLUSIONS Patients with new or persistent new LBBB 1 year after AVR had lower mean Euroscore II and BMI values. Their stay at the hospital was also shorter.
Collapse
Affiliation(s)
- Rafał Januszek
- Department of Cardiology and Cardiovascular Interventions, University Hospital, 30-688 Kraków, Poland
| | - Robert Balan
- Department of Cardiac Surgery, Klinikum Passau, 94-032 Passau, Germany;
| |
Collapse
|
3
|
Mogilansky C, Massoudy P, Czesla M, Balan R. Conduction Disorders after Surgical Aortic Valve Replacement Using a Rapid Deployment Aortic Valve Prosthesis: Medium-Term Follow-Up. J Clin Med 2023; 12:jcm12052083. [PMID: 36902870 PMCID: PMC10004204 DOI: 10.3390/jcm12052083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 02/25/2023] [Accepted: 02/28/2023] [Indexed: 03/09/2023] Open
Abstract
BACKGROUND We have previously reported that the incidence of postoperative conduction disorders, especially left bundle branch block (LBBB), after implantation of a rapid deployment Intuity™ Elite aortic valve prosthesis (Edwards Lifesciences, Irvine, CA, USA), was significantly increased compared with conventional aortic valve replacement. We were now interested in how these disorders behaved at intermediate follow-up. METHODS All 87 patients who had undergone surgical aortic valve replacement (SAVR) using the rapid deployment Intuity™ Elite prosthesis and were shown to have conduction disorders at the time of hospital discharge were followed up after surgery. These patients' ECGs were recorded at least 1 year after surgery, and the persistence of the new postoperative conduction disorders was assessed. RESULTS At hospital discharge, 48.1% of the patients had developed new postoperative conduction disorders, with LBBB being the predominant conduction disturbance (36.5%). At medium-term follow-up (526 days, standard deviation (SD) = 169.6, standard error (SE) = 19.3 days, respectively), 44% of the new LBBB and 50% of the new right bundle branch block (RBBB) had disappeared. There was no new atrio-ventricular block III (AVB III) that occurred. One new pacemaker (PM) was implanted during follow-up because of AVB II Mobitz type II. CONCLUSIONS At medium-term follow-up after the implantation of a rapid deployment Intuity™ Elite aortic valve prosthesis, the number of new postoperative conduction disorders, especially LBBB, has considerably decreased but remains high. The incidence of postoperative AV block III remained stable.
Collapse
|
4
|
Dokollari A, Torregrossa G, Sicouri S, Veshti A, Margaryan R, Cameli M, Mandoli GE, Maccherini M, Montesi G, Cabrucci F, Coku L, Arora R, Li QR, Bonacchi M, Gelsomino S. Pearls, pitfalls, and surgical indications of the Intuity TM heart valve: A rapid deployment bioprosthesis. A systematic review of the literature. J Card Surg 2022; 37:5411-5417. [PMID: 36403259 DOI: 10.1111/jocs.17231] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 10/27/2022] [Accepted: 10/31/2022] [Indexed: 11/21/2022]
Abstract
OBJECTIVES To highlight short- and long-term clinical outcomes of the Intuity TM rapid deployment prosthesis for surgical aortic valve replacement. METHODS We reviewed on PubMed/MEDLINE, Embase, SciELO, LILACS, CCTR/CENTRAL, and Google Scholar for clinical trials, retrospective clinical studies, meta-analysis, and gray literature. RESULTS Fourty-five clinical studies with 12.714 patients were included in the analysis. Thirty-day mortality ranged from 3.8% for Intuity and 3.9% for transcatheter aortic valve replacement (TAVR). The incidence of paravalvular leak (PVL) (Intuity 0% and TAVR 2.17%), permanent pacemaker implantation (Intuity 11.11% and TAVR 12.5%), stroke (Intuity 2.2% and TAVR 2.6%), myocardial infarction (MI) (Intuity 0% and TAVR 1%), were all higher in the TAVR group. Compared to other sutured bioprosthesis (SB), mortality ranged from 0% to 3.9% for Intuity and 0%-6.9% for SB. Long-term cardiac mortality ranged from 0.9% to 1.55% for Intuity and 1.4%-3.3% for the Perceval valve. The incidence of PVL (Intuity 0.24%-0.7% and Perceval 0%-1%), endocarditis (Intuity 0.2%-0.7% and Perceval 1.6%-6.6%), stroke (Intuity 0.36%-1.4% and Perceval 0%-0.8%), MI (Intuity 0.07%-0.26%), and SVD (Intuity 0.12%-0.7% and Perceval 0%) were comparable. Compared to standard full sternotomy (SFS), minimally invasive surgery (MINV) mortality ranged from 0% to 4.3% for MINV and 0%-2.1% for SFS. Hospital costs outcomes ranged from $37,187-$44,368 for the Intuity, $69,389 for TAVR, and $13,543 for SB. Intuity short-term mortality ranged between 0.9% and 12.4% while long-term mortality ranged between 2.6% and 20%. CONCLUSIONS This manuscript provides a 360° overview of the current rapid deployments, sutureless, and TAVR prosthesis.
Collapse
Affiliation(s)
- Aleksander Dokollari
- Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA.,Department of Cardiothoracic Surgery, Lankenau Medical Center, Lankenau Heart Institute, Main Line Health, Wynnewood, Pennsylvania, USA
| | - Gianluca Torregrossa
- Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA.,Department of Cardiothoracic Surgery, Lankenau Medical Center, Lankenau Heart Institute, Main Line Health, Wynnewood, Pennsylvania, USA
| | - Serge Sicouri
- Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA
| | - Altin Veshti
- Department of Cardiac Surgery, Mother Teresa Hospital, University of Tirana, Tirana, Albania
| | - Rafik Margaryan
- Department of Adult Cardiac Surgery, G. Pasquinucci Heart Hospital, Fondazione CNR-G. Monasterio, Massa, Italy
| | - Matteo Cameli
- Department of Experimental and Clinical Medicine, Cardiac Surgery Unit, University of Florence, Firenze, Italy
| | - Giulia Elena Mandoli
- Department of Experimental and Clinical Medicine, Cardiac Surgery Unit, University of Florence, Firenze, Italy
| | - Massimo Maccherini
- Department of Experimental and Clinical Medicine, Cardiac Surgery Unit, University of Florence, Firenze, Italy
| | - Gianfranco Montesi
- Department of Experimental and Clinical Medicine, Cardiac Surgery Unit, University of Florence, Firenze, Italy
| | - Francesco Cabrucci
- Department of Cardiac Surgery/Cardiology, University of Siena, Siena, Italy
| | - Lindita Coku
- Department of Cardiac Surgery, Appalachian Regional Health, University of Kentucky, Hazard, Kentucky, USA
| | - Rakesh Arora
- Department of Surgery, Section of Cardiac Surgery, Max Rady College of Medicine, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Qiao Ri Li
- 2010 Vision Associates, Toronto, Ontario, Canada
| | - Massimo Bonacchi
- Department of Cardiac Surgery/Cardiology, University of Siena, Siena, Italy
| | - Sandro Gelsomino
- Department of Cardiac Surgery, CARIM Maastricht Medical University, Maastricht, Netherlands
| |
Collapse
|
5
|
Mechulan A, Demoulin R, Dieuzaide P, Peret A, Vaillant A, Vicat J, Bouharaoua A, Leude-Vaillant E, Cornen A, Prevot S. Early pacemaker insertion after aortic valve replacement with an Edwards Intuity sutureless valve. Arch Cardiovasc Dis 2022; 115:490-495. [PMID: 36127272 DOI: 10.1016/j.acvd.2022.05.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 05/16/2022] [Accepted: 05/19/2022] [Indexed: 11/02/2022]
Abstract
BACKGROUND Postoperative conduction disorders are serious adverse events in patients undergoing aortic valve replacement, and may prolong the duration of hospitalization and require pacemaker insertion. AIM Our aim was to evaluate the rate of pacemaker insertion after implantation of an Edwards Intuity sutureless aortic valve (Edwards Lifesciences, Irvine, CA, USA) compared with a standard surgical bioprosthesis. METHODS This retrospective single-centre study included patients who underwent aortic valve replacement with an Intuity sutureless aortic valve or a standard bioprosthetic valve between 4 June 2014 and 27 June 2016. The main outcome criterion was the rate of postoperative pacemaker insertion. Secondary outcome criteria included the rate of new conduction disorders, the rate of atrial arrhythmia or paroxysmal conduction disorders, mortality and duration of hospital stay. RESULTS Ninety-three patients received an Intuity sutureless aortic valve (median age 76 years, interquartile range 71-80 years), and 176 were implanted with a standard biological aortic valve (median age 73 years, interquartile range 68-79 years; P=0.007). The rate of postoperative pacemaker insertion, after adjustment, was 22.44% in the Intuity group and 5.66% in the standard aortic valve group (P=0.030). The main indications for postoperative pacemaker insertion were complete atrioventricular block and left bundle branch block with prolongation of the H-V interval. The rate of new postoperative left bundle branch block conduction disorders was significantly higher in patients implanted with an Intuity valve (odds ratio 5.28, 95% confidence interval 1.59 to 23.05; P=0.012). CONCLUSION Higher rates of pacemaker insertion and new conduction disorders were observed in patients implanted with an Intuity sutureless bioprosthesis compared with those who received a standard surgical aortic valve.
Collapse
Affiliation(s)
- Alexis Mechulan
- Service de cardiologie, Ramsay Santé, hôpital privé Clairval, 13009 Marseille, France.
| | - Raphaël Demoulin
- Service de cardiologie, hôpital d'instruction des armées Sainte-Anne, 83800 Toulon, France
| | - Pierre Dieuzaide
- Service de cardiologie, Ramsay Santé, hôpital privé Clairval, 13009 Marseille, France
| | - Angélique Peret
- Service de cardiologie, Ramsay Santé, hôpital privé Clairval, 13009 Marseille, France
| | - Alain Vaillant
- Service de chirurgie cardiaque, Ramsay Santé, hôpital privé Clairval, 13009 Marseille, France
| | - Jacques Vicat
- Service de chirurgie cardiaque, Ramsay Santé, hôpital privé Clairval, 13009 Marseille, France
| | - Ahmed Bouharaoua
- Service de cardiologie, Ramsay Santé, hôpital privé Clairval, 13009 Marseille, France
| | | | - Alain Cornen
- Service de chirurgie cardiaque, Ramsay Santé, hôpital privé Clairval, 13009 Marseille, France
| | - Sébastien Prevot
- Service de cardiologie, Ramsay Santé, hôpital privé Clairval, 13009 Marseille, France
| |
Collapse
|
6
|
Hori D, Yamamoto T, Kusadokoro S, Fujimori T, Mieno MN, Kimura N, Yamaguchi A. Evaluation of oversizing in association with conduction disorder after implantation of a rapid deployment valve. J Artif Organs 2021; 25:238-244. [PMID: 34727259 DOI: 10.1007/s10047-021-01301-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Accepted: 10/21/2021] [Indexed: 10/19/2022]
Abstract
Rapid deployment valve has expanded surgical indication for high-risk patients with aortic stenosis despite its accommodated risk for conduction disorder (CD). The purpose of this study was to evaluate the degree of oversizing in association with postoperative CD. During June 2019 to September 2021, 25 patients underwent aortic valve replacement with Edwards INTUITY. Device size selection was evaluated intraoperatively using provided sizers. Oversizing was evaluated retrospectively by measuring the difference of the dimension of the annulus and left ventricular outflow tract (LVOT) compared to the dimensions of the device used by preoperative-computed tomography. Although there was no incidence of pacemaker implantation, seven patients (28.0%) experienced CD after surgery. There was no difference in device area and annulus area (CD: - 37 ± 22.7 mm2 vs. no CD: - 56 ± 63.6 mm2, p = 0.47), and device circumference and annulus circumference (CD: - 4.4 ± 2.77 mm vs. no CD: - 6.9 ± 5.60 mm, p = 0.26) in patients with and without CD. However, there was a significant difference in area of the device skirt and sub-annular area at the LVOT (CD: 114 ± 28.4 mm2 vs. no CD: - 8 ± 80.0 mm2, p < 0.001), and circumference of device skirt and the LVOT (CD: 3.9 ± 2.08 mm vs. no CD: - 4.6 ± 5.24 mm, p < 0.001) between the two groups. Receiver operating characteristic curve analysis showed that an area difference of 77.7 mm2 and circumference difference of 0.91 mm at LVOT were associated with postoperative CD with specificities of 0.83, 0.78 and sensitivity of 1.0, 1.0, respectively. Preoperative measurement of the LVOT may be useful in evaluating the risk of postoperative CD in patients receiving rapid deployment valve.
Collapse
Affiliation(s)
- Daijiro Hori
- Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma-cho, Omiya-ku, Saitama-Shi, Saitama, 330-8503, Japan.
| | - Takahiro Yamamoto
- Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma-cho, Omiya-ku, Saitama-Shi, Saitama, 330-8503, Japan
| | - Sho Kusadokoro
- Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma-cho, Omiya-ku, Saitama-Shi, Saitama, 330-8503, Japan
| | - Tomonari Fujimori
- Department of Medical Informatics, Center for Information, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke-shi, Tochigi, 329-0498, Japan
| | - Makiko Naka Mieno
- Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma-cho, Omiya-ku, Saitama-Shi, Saitama, 330-8503, Japan
| | - Naoyuki Kimura
- Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma-cho, Omiya-ku, Saitama-Shi, Saitama, 330-8503, Japan
| | - Atsushi Yamaguchi
- Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma-cho, Omiya-ku, Saitama-Shi, Saitama, 330-8503, Japan
| |
Collapse
|
7
|
Verlinden J, Bové T, de Kerchove L, Baert J, Radermecker M, Durieux R, Gutermann H, Van Kerrebroeck C, Szecel D, Meuris B. Early conduction disorders after aortic valve replacement with the sutureless Perceval prosthesis. Ann Thorac Surg 2021; 113:1911-1917. [PMID: 34536377 DOI: 10.1016/j.athoracsur.2021.08.020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 07/23/2021] [Accepted: 08/10/2021] [Indexed: 11/27/2022]
Abstract
BACKGROUND To determine the incidence of postoperative conduction disorders and need for pacemaker implantation after aortic valve replacement(AVR) with the Perceval prosthesis. METHODS From January 2007 to December 2017, 908 patients underwent AVR with Perceval S in 5 participating centers. Study endpoints focused on electrocardiographic changes after AVR and the incidence of new pacemaker(PM) implantation in 801 patients after exclusion of patients with previous PM(n=48) or patients undergoing tricuspid(n=28) and/or AF ablation(n=31) surgery. Logistic regression analysis was performed to determine risk factors for PM need. RESULTS Mean age was 79.7±5.2 years, 476(59.4%) were females. Median logistic Euroscore II was 4.1%(IQR 2.6-6.0). Isolated AVR was performed in 441(55.1%) patients. Associated procedures were CABG(n=309, 38.6%) and mitral valve surgery(n=51, 6.4%). Overall 30d-mortality was 3.9%, and 2.8% for isolated AVR. Electrocardiographic changes included a significant increase of LBBB (7.4 to 23.7%, p<0.001) and development of complete AV block, requiring PM implantation in 9.5%. Multivariable analysis revealed independent of a learning period(OR 1.91, 95%CI 1.16-3.13, p=0.011), pre-existing RBBB(OR 2.77, 95%CI 1.40-5.48, p=0.003), intra-operative prosthesis repositioning(OR 6.70, 95%CI 1.89-24.40, p=0.003) and size XL(OR 6.81, 95%CI 1.55-29.96, p=0.011) as significant predictors of PM implantation. CONCLUSIONS In a challenging elderly population, use of the Perceval S for AVR provides low operative mortality, but at the risk of an increased PM implantation rate. Besides to pre-existing right-bundle branch block, the significant effect of size XL, an increased valve size/BSA ratio and need for intra-operative repositioning on PM rate are underscoring the reappraisal of the annular sizing policy.
Collapse
Affiliation(s)
| | | | | | - Jerome Baert
- University Hospital UCL St Luc-Brussels, Brussels, Belgium
| | | | | | | | | | | | - Bart Meuris
- University Hospital KUL Leuven, Leuven, Belgium
| |
Collapse
|
8
|
Herry M, Laghlam D, Touboul O, Nguyen LS, Estagnasié P, Brusset A, Squara P. Pacemaker implantation after aortic valve replacement: rapid-deployment Intuity® compared to conventional bioprostheses. Eur J Cardiothorac Surg 2021; 58:335-342. [PMID: 32215660 PMCID: PMC7373323 DOI: 10.1093/ejcts/ezaa068] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Revised: 02/03/2020] [Accepted: 02/05/2020] [Indexed: 02/06/2023] Open
Affiliation(s)
- Morgane Herry
- Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France
| | - Driss Laghlam
- Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France
| | - Olivier Touboul
- Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France
| | - Lee S Nguyen
- Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France
| | - Philippe Estagnasié
- Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France
| | - Alain Brusset
- Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France
| | - Pierre Squara
- Department of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France
- Corresponding author. Department of Cardiology and Critical Care, CERIC, Clinique Ambroise Paré, 27 Boulevard Victor Hugo, 92200 Neuilly-sur-Seine, France. Tel: +33-6-07370425; e-mail: (P. Squara)
| |
Collapse
|
9
|
Klop IDG, Kougioumtzoglou AM, Kloppenburg GTL, van Putte BP, Sprangers MAG, Klein P, Nieuwkerk PT. Short-term outcome of the intuity rapid deployment prosthesis: a systematic review and meta-analysis. Interact Cardiovasc Thorac Surg 2021; 31:427-436. [PMID: 32910171 DOI: 10.1093/icvts/ivaa131] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 05/15/2020] [Accepted: 06/17/2020] [Indexed: 01/18/2023] Open
Abstract
OBJECTIVES Limited access aortic valve replacement is an alternative approach for the treatment of calcified aortic valve disease. To facilitate limited access aortic valve replacement, rapid deployment valve prostheses have been developed aiming to reduce surgical impact. This systematic review gives an overview of current literature regarding the INTUITY or INTUITY Elite rapid deployment biological valve prosthesis. METHODS Cochrane, Embase and MEDLINE were searched to identify relevant studies. All studies reporting on patients who underwent isolated or combined surgical aortic valve replacement with the INTUITY or INTUITY Elite valve prosthesis were considered eligible. Primary end points were technical success rate, 30-day mortality, cerebrovascular accident, paravalvular leak and permanent pacemaker implantation. Secondary end points included procedural data such as aortic cross-clamping time, cardiopulmonary bypass time and procedural approach. RESULTS A total of 16 articles fulfilled the inclusion and exclusion criteria and comprised 4.184 patients. Thirty-day mortality was 2.7% (1.9-3.7%), cerebrovascular accident 2.6% (1.4-4.7%), permanent pacemaker implantation 7.9% (6.6-9.5%) and severe postoperative paravalvular leak requiring a reintervention 3.3% (1.7-6.1%). Technical success rate varied between 93.9% and 100%. Conventional median sternotomy was most commonly performed, ranging from 21.7% to 89.6%. Upper hemi-sternotomy was performed more often than anterior right thoracotomy, ranging from 10.4% to 63.3% and 2.2% to 26.1%. The mean transvalvular pressure gradient ranged between 9.0 and 10.3 mmHg at 1 year postoperatively. CONCLUSIONS This review demonstrates that the technical success rate of the INTUITY or INTUITY Elite rapid deployment valve system is high, also in limited access aortic valve replacement. Mortality and cerebrovascular accident rates are low, but the need for postoperative permanent pacemaker implantation and reintervention rate for paravalvular leakage is increased.
Collapse
Affiliation(s)
| | - Athiná M Kougioumtzoglou
- Department of Cardiothoracic Surgery, Amsterdam University Medical Centers, Academic Medical Center, Amsterdam, Netherlands
| | | | - Bart P van Putte
- Department of Cardiothoracic Surgery, St. Antonius Ziekenhuis, Nieuwegein, Netherlands.,Department of Cardiothoracic Surgery, Amsterdam University Medical Centers, Academic Medical Center, Amsterdam, Netherlands
| | - Mirjam A G Sprangers
- Department of Psychology, Amsterdam University Medical Centers, Academic Medical Center, University of Amsterdam, Amsterdam Public Health Research Institute, Amsterdam, Netherlands
| | - Patrick Klein
- Department of Cardiothoracic Surgery, St. Antonius Ziekenhuis, Nieuwegein, Netherlands
| | - Pythia T Nieuwkerk
- Department of Psychology, Amsterdam University Medical Centers, Academic Medical Center, University of Amsterdam, Amsterdam Public Health Research Institute, Amsterdam, Netherlands
| |
Collapse
|
10
|
Sohn SH, Kim KH, Kang Y, Kim JS, Choi JW. Recovery from Conduction Abnormalities after Aortic Valve Replacement using Edwards Intuity. Ann Thorac Surg 2021; 112:1356-1362. [PMID: 33905729 DOI: 10.1016/j.athoracsur.2021.04.036] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 03/31/2021] [Accepted: 04/05/2021] [Indexed: 11/15/2022]
Abstract
PURPOSE This study investigated the incidences of various conduction abnormalities after rapid-deployment aortic valve replacement(RDAVR) using Edwards Intuity and the temporal changes of these abnormalities during the postoperative course. DESCRIPTION We modified the procedure by placing additional anchoring sutures and using a 5-mm videoscope to achieve 'complete annulus fitting'. Direct visual inspection by videoscopy inside and outside the valve guaranteed 'complete annulus fitting'. EVALUATION Overall 167 patients who underwent RDAVR during the study period were included in the analysis of postoperative conduction abnormalities. After RDAVR, third-degree atrioventricular block occurred in 18 patients(10.8%), but 15 patients recovered to sinus rhythm at median postoperative 10 days. Left or right bundle branch block occurred in 67 patients(40.1%), but 44 patients returned to their original rhythm at median postoperative 12 days. Delayed-onset conduction abnormalities occurred in 35 patients(21.0%) at median postoperative day 4, but they spontaneously regressed in 28 patients. CONCLUSIONS The incidence of conduction abnormalities after RDAVR was high, but most of these abnormalities spontaneously recovered. These good results may be attributed to our implantation technique.
Collapse
Affiliation(s)
- Suk Ho Sohn
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Kyung Hwan Kim
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
| | - Yoonjin Kang
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Ji Seong Kim
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Jae Woong Choi
- Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| |
Collapse
|
11
|
Deutsch O, Deisenhofer I, Koch-Buettner K, Lange R, Krane M. Need for permanent pacemaker implantation following implantation of the rapid deployment valve in combined procedures: a single centre cohort study. J Thorac Dis 2021; 13:2128-2136. [PMID: 34012563 PMCID: PMC8107573 DOI: 10.21037/jtd-20-3120] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background Rapid deployment aortic valves may interfere with the cardiac conduction system. We investigated the need for permanent pacemaker implantation (PPI) following the implantation of Edwards INTUITY valve (Edwards Lifesciences, Irvine, CA). Methods One hundred twenty patients underwent aortic valve replacement (AVR) with the INTUITY valve in a combined procedure at the German Heart Centre Munich between April 2016 and December 2019. Twenty-four patients with prior PPI or concomitant ablation procedures (24/120, 20%) were excluded. Patient-specific, procedural and post-procedural outcomes were assessed in the remaining 96 cases. Results AVR was successful in all cases. Seventy-four percent of the study population were men. Mean age was 69.5±7.6 years. EuroSCORE II was 3.2±2.9. Forty-six patients (46/96, 47.9%) presented with pre-operative conduction disorders, right bundle branch block (RBBB) (17/96, 17.7%) and first-degree or second degree atrio-ventricular block (AVB) (18/96, 18.8%), in particular. In total, 9 patients (9/96, 9.4%) underwent PPI. PPI was required in 3 patients (3/50, 6.0%) who did not have a pre-existing conduction disorder due to new high degree AVB. 6 patients with pre-operative conduction disorders (6/46, 13%) needed PPI. Timing of PPI was 5.2±1.5 days (median 5). Independent predictors of PPI were preoperative RBBB [odds ratio (OR) =4.554, P=0.049] and large valve size (#27) (OR =5.527, P=0.031). Conclusions The analysis of the data collected enabled us to identify patient factors associated with higher risk for post-operative PPI following AVR with the INTUITY valve. Patient factors associated with post-operative PPI, were RBBB and large valve size. These patients should be closely monitored following the procedure, in particular.
Collapse
Affiliation(s)
- Oliver Deutsch
- Department of Cardiovascular Surgery, German Heart Centre Munich of the Technical University Munich, Munich, Germany.,INSURE (Institute for Translational Cardiac Surgery), German Heart Centre Munich, Munich, Germany
| | - Isabell Deisenhofer
- Department of Cardiology, German Heart Centre Munich of the Technical University Munich, Munich, Germany
| | - Katharina Koch-Buettner
- Department of Cardiology, German Heart Centre Munich of the Technical University Munich, Munich, Germany
| | - Rüdiger Lange
- Department of Cardiovascular Surgery, German Heart Centre Munich of the Technical University Munich, Munich, Germany.,INSURE (Institute for Translational Cardiac Surgery), German Heart Centre Munich, Munich, Germany.,DZHK (German Centre for Cardiovascular Research)-Partner Site Munich, Munich Heart Alliance, Munich, Germany
| | - Markus Krane
- Department of Cardiovascular Surgery, German Heart Centre Munich of the Technical University Munich, Munich, Germany.,INSURE (Institute for Translational Cardiac Surgery), German Heart Centre Munich, Munich, Germany.,DZHK (German Centre for Cardiovascular Research)-Partner Site Munich, Munich Heart Alliance, Munich, Germany
| |
Collapse
|
12
|
Berretta P, Montecchiani L, Vagnarelli F, Cefarelli M, Alfonsi J, Zingaro C, Capestro F, Pierri MD, D'alfonso A, Di Eusanio M. Conduction disorders after aortic valve replacement: what is the real impact of sutureless and rapid deployment valves? Ann Cardiothorac Surg 2020; 9:386-395. [PMID: 33102177 DOI: 10.21037/acs-2020-surd-26] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background Although sutureless and rapid deployment aortic valve replacement (SURD-AVR) has been associated with an increased rate of permanent pacemaker (PPM) implantation compared to conventional AVR (c-AVR), the predictors of new conduction abnormalities remain to be clarified. This study aimed to identify risk factors for conduction disorders in patients undergoing AVR surgery. Methods Data from 243 patients receiving minimally invasive AVR were prospectively collected. SURD-AVR was performed in 103 (42.4%) patients and c-AVR in 140 (57.6%). The primary endpoint was the occurrence of new-onset conduction disorders, defined as first degree atrioventricular (AV) block, advanced AV block requiring PPM implantation, left anterior fascicular block (LAFB), left bundle branch block (LBBB) and right bundle branch block (RBBB). Results The unadjusted comparison revealed that SURD-AVR was associated with a higher rate of advanced AV block requiring PPM when compared with c-AVR (10.5% vs. 2.1%, P=0.01). After adjusting for other measured covariates (OR: 1.6, P=0.58) and for the estimated propensity of SURD-AVR (OR: 5.1, P=0.1), no significant relationship between type of AVR and PPM implantation emerged. On multivariable analysis, preoperative first-degree AV block (OR: 6.9, P=0.04) and RBBB (OR: 6.9, P=0.03) were independent risk factors for PPM. Subgroup analysis of patients with normal preoperative conduction revealed similar incidence of PPM between SURD-AVR and c-AVR (1.3% vs. 1.9%, P=0.6). When compared with c-AVR, SURD-AVR was associated with a greater incidence of postoperative new onset LBBB (18.1% vs. 3.2%, P<0.001). This finding was confirmed after adjusting for the estimated propensity of SURD-AVR (OR: 6.3, P=0.009). Conclusions Our study revealed that the risk of PPM implantation in patients receiving surgical AVR is heavily influenced by the presence of pre-existing conduction disturbances rather than the type of valve prosthesis. Conversely, SURD-AVR emerged as an independent predictor for LBBB and was associated with an increased risk of PPM in patients presenting with RBBB.
Collapse
Affiliation(s)
- Paolo Berretta
- Cardiac Surgery Unit, Lancisi Cardiovascular Center, Polytechnic University of Marche, Ancona, Italy
| | - Luca Montecchiani
- Cardiac Surgery Unit, Lancisi Cardiovascular Center, Polytechnic University of Marche, Ancona, Italy
| | | | - Mariano Cefarelli
- Cardiac Surgery Unit, Lancisi Cardiovascular Center, Polytechnic University of Marche, Ancona, Italy
| | - Jacopo Alfonsi
- Cardiac Surgery Unit, Lancisi Cardiovascular Center, Polytechnic University of Marche, Ancona, Italy
| | - Carlo Zingaro
- Cardiac Surgery Unit, Lancisi Cardiovascular Center, Polytechnic University of Marche, Ancona, Italy
| | - Filippo Capestro
- Cardiac Surgery Unit, Lancisi Cardiovascular Center, Polytechnic University of Marche, Ancona, Italy
| | - Michele D Pierri
- Cardiac Surgery Unit, Lancisi Cardiovascular Center, Polytechnic University of Marche, Ancona, Italy
| | - Alessandro D'alfonso
- Cardiac Surgery Unit, Lancisi Cardiovascular Center, Polytechnic University of Marche, Ancona, Italy
| | - Marco Di Eusanio
- Cardiac Surgery Unit, Lancisi Cardiovascular Center, Polytechnic University of Marche, Ancona, Italy
| |
Collapse
|