1
|
Wang H, Liu R, Yu Y, Xue H, Shen R, Zhang Y, Ding J. Effects of cell shape and nucleus shape on epithelial-mesenchymal transition revealed using chimeric micropatterns. Biomaterials 2025; 317:123013. [PMID: 39733514 DOI: 10.1016/j.biomaterials.2024.123013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2024] [Revised: 11/16/2024] [Accepted: 12/13/2024] [Indexed: 12/31/2024]
Abstract
Epithelial-mesenchymal transition (EMT) is a key phenotypic switch in cancer metastasis, leading to fatal consequences for patients. Under geometric constraints, the morphology of cancer cells changes in both cellular and subcellular levels, whose effects on EMT are, however, not fully understood. Herein, we designed and fabricated chimeric micropatterns of polystyrene (PS) with adhesion contrast to reveal the impacts of cell shapes and nuclear shapes on EMT in a decoupled way. Cell elongation was modulated via microwell aspect ratios (ARs), and nuclear deformation was generated through a micropillar array in the microwell. Human non-small cell lung cancer cells (A549) were cultured on the quasi-three dimensional micropatterned surfaces, and transforming growth factor-β1 (TGF-β1) was added to induce EMT. We found that chimeric micropatterns upregulated EMT with an increase of cellular AR and nuclear indentation under given TGF-β1. The subsequent assessment of the contractility and oriented assembly of microfilaments elucidated the key role of mechanotransduction in cell elongation and EMT, as proved by myosin inhibition, while it was obstructed by micropillars in the chimeric micropattern. Hence, the micropillar array possessed a nonmonotonic influence, enhancing the EMT of cells with AR of 1, but hindering the EMT with an impact more significant on microwells with large ARs due to the impeded cytoskeleton assembly. This fundamental research has illustrated the complex of cellular and subcellular geometries on cell behaviors including phenotype transition in cancer metastasis.
Collapse
Affiliation(s)
- Hongyu Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| | - Ruili Liu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| | - Yue Yu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| | - Hongrui Xue
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| | - Runjia Shen
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| | - Yanshuang Zhang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| | - Jiandong Ding
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China.
| |
Collapse
|
2
|
Yu Y, Dai M, Li M, Song G, Yin Y, Wang J. Bioabsorbable Stent-Covering with Sustained Anticoagulant Activity Fabricated via Alternate Layer-by-Layer Self-Assembly of Heparin and Silk Fibroin. ACS APPLIED MATERIALS & INTERFACES 2025; 17:17921-17931. [PMID: 40067147 DOI: 10.1021/acsami.4c16643] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/28/2025]
Abstract
For severe local vasculopathy, covered stents are considered the major medical devices in interventional therapy due to their function to isolate lesions and deliver drugs. However, commercial stent-coverings have unsatisfactory drug-loading capacity and lack bioactivity. Silk fibroin (SF) possesses excellent biocompatibility, biodegradability, and endothelialization ability. In this study, we developed a bioabsorbable SF stent-covering loaded with heparin (Hep) via layer-by-layer self-assembly. Hep was embedded in the stent-covering via interfacial adsorption (Hep-SF) or direct blending with SF (Hep/SF). For interfacial adsorption, the Hep loading capacity increased with adsorption time and Hep concentration, reaching up to 589 μg/cm2. All Hep-modified SF stent-coverings were nonhemolytic. After Hep modification, the recalculation time of the Hep-SF stent-covering was significantly prolonged (>2 h), platelet adhesion to its surface was reduced, and no obvious clots formed. Compared to the Hep/SF stent-coverings, the release quantity of Hep from the Hep-SF stent-covering was higher at each time point, regardless of diffusion or enzymatic degradation, but its diffusion release rate was lower than that of the high-dosage Hep/SF stent-covering, suggesting that the Hep-SF stent-covering had more sustained Hep release. Moreover, the released Hep maintained a high anticoagulant activity to significantly prolong activated partial thromboplastin time and thrombin time after long-time diffusion or enzymatic degradation. The results indicated that the Hep-SF stent-covering developed in this study not only had a high loading capacity for anticoagulant drugs (on-demand adjustable) but also could achieve effective and sustained anticoagulant function until the SF material was completely degraded.
Collapse
Affiliation(s)
- Yangxiao Yu
- College of Textile and Clothing Engineering, Soochow University, Suzhou, Jiangsu 215123, China
| | - Mengnan Dai
- College of Textile and Clothing Engineering, Soochow University, Suzhou, Jiangsu 215123, China
| | - Meng Li
- College of Textile and Clothing Engineering, Soochow University, Suzhou, Jiangsu 215123, China
| | - Guangzhou Song
- College of Textile and Clothing Engineering, Soochow University, Suzhou, Jiangsu 215123, China
| | - Yin Yin
- Department of Medicine, Soochow University, Suzhou, Jiangsu 215123, China
| | - Jiannan Wang
- College of Textile and Clothing Engineering, Soochow University, Suzhou, Jiangsu 215123, China
- National Engineering Laboratory for Modern Silk, Soochow University, Suzhou, Jiangsu 215123, China
| |
Collapse
|
3
|
Shi D, Kang Y, Wang W, Liu R, Tang Q, Li Z, Jiang H, Ding J. Biodegradable polymeric occluder with controllable locking structure for closure of atrial septal defect via interventional treatment. Regen Biomater 2025; 12:rbaf016. [PMID: 40248504 PMCID: PMC12005900 DOI: 10.1093/rb/rbaf016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2025] [Revised: 02/24/2025] [Accepted: 03/17/2025] [Indexed: 04/19/2025] Open
Abstract
Atrial septal defect (ASD) is one of the major congenital heart diseases, and transcatheter closure with a cardiac occluder is a modern method to treat ASD with the advantage of mini-invasiveness over traditional surgical closure. While current occlusion devices are mainly made of non-degradable nitinol with superelasticity, the permanent existence of a metal in vivo may trigger potential complications and especially has an adverse effect on the heart development for children. However, it is challenging to invent a superelasticity-free occluder that can be delivered through a catheter but firmly locked after being opened at the target site; it is also much desired for research and development to quickly assess the feasibility of a superelasticity-free occluder in vitro. Herein, a biodegradable poly(L-lactide) (PLLA) occluder composed of a braided PLLA frame as the skeleton and a nonwoven PLLA fabric as the flow-blocking membrane is developed, and a controllable locking structure is designed to enable firm closure for a device even without superelasticity. We also suggest and justify a series of in vitro methods to assess the efficacy of the biodegradable occluder, and the results confirm the reliability of locking, water-blocking, mechanical strength and degradability. It is found that the PLLA fabric with moderate fiber density is optimal for surface endothelialization. We also carry out biological assessments; significant endothelialization and alleviated inflammation response are observed after 6 months of subcutaneous implantation into rabbits. The porcine model illustrates that the biodegradable polymeric occluder can be successfully implanted into the atrial septum via transcatheter intervention; the follow-ups have confirmed the safety and efficacy of this biodegradable polymeric occluder with the controllable locking structure.
Collapse
Affiliation(s)
- Daokun Shi
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Yahong Kang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
- Shanghai Key Laboratory of Interventional Medical Devices and Equipment, Shanghai MicroPort Medical Group Co, Ltd, Shanghai 201203, China
- AccuPath Group Co., Ltd, Jiaxing 314000, China
| | - Weijie Wang
- Shanghai Key Laboratory of Interventional Medical Devices and Equipment, Shanghai MicroPort Medical Group Co, Ltd, Shanghai 201203, China
- AccuPath Group Co., Ltd, Jiaxing 314000, China
| | - Ruili Liu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Quansheng Tang
- Shanghai Key Laboratory of Interventional Medical Devices and Equipment, Shanghai MicroPort Medical Group Co, Ltd, Shanghai 201203, China
- AccuPath Group Co., Ltd, Jiaxing 314000, China
| | - Zhaomin Li
- Shanghai Key Laboratory of Interventional Medical Devices and Equipment, Shanghai MicroPort Medical Group Co, Ltd, Shanghai 201203, China
- AccuPath Group Co., Ltd, Jiaxing 314000, China
| | - Hongyan Jiang
- Shanghai Key Laboratory of Interventional Medical Devices and Equipment, Shanghai MicroPort Medical Group Co, Ltd, Shanghai 201203, China
| | - Jiandong Ding
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| |
Collapse
|
4
|
Wu H, Feng E, Yin H, Zhang Y, Chen G, Zhu B, Yue X, Zhang H, Liu Q, Xiong L. Biomaterials for neuroengineering: applications and challenges. Regen Biomater 2025; 12:rbae137. [PMID: 40007617 PMCID: PMC11855295 DOI: 10.1093/rb/rbae137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2024] [Revised: 10/19/2024] [Accepted: 11/03/2024] [Indexed: 02/27/2025] Open
Abstract
Neurological injuries and diseases are a leading cause of disability worldwide, underscoring the urgent need for effective therapies. Neural regaining and enhancement therapies are seen as the most promising strategies for restoring neural function, offering hope for individuals affected by these conditions. Despite their promise, the path from animal research to clinical application is fraught with challenges. Neuroengineering, particularly through the use of biomaterials, has emerged as a key field that is paving the way for innovative solutions to these challenges. It seeks to understand and treat neurological disorders, unravel the nature of consciousness, and explore the mechanisms of memory and the brain's relationship with behavior, offering solutions for neural tissue engineering, neural interfaces and targeted drug delivery systems. These biomaterials, including both natural and synthetic types, are designed to replicate the cellular environment of the brain, thereby facilitating neural repair. This review aims to provide a comprehensive overview for biomaterials in neuroengineering, highlighting their application in neural functional regaining and enhancement across both basic research and clinical practice. It covers recent developments in biomaterial-based products, including 2D to 3D bioprinted scaffolds for cell and organoid culture, brain-on-a-chip systems, biomimetic electrodes and brain-computer interfaces. It also explores artificial synapses and neural networks, discussing their applications in modeling neural microenvironments for repair and regeneration, neural modulation and manipulation and the integration of traditional Chinese medicine. This review serves as a comprehensive guide to the role of biomaterials in advancing neuroengineering solutions, providing insights into the ongoing efforts to bridge the gap between innovation and clinical application.
Collapse
Affiliation(s)
- Huanghui Wu
- Translational Research Institute of Brain and Brain-Like Intelligence, Shanghai Key Laboratory of Anesthesiology and Brain Functional Modulation, Clinical Research Center for Anesthesiology and Perioperative Medicine, Department of Anesthesiology and Perioperative Medicine, Shanghai Fourth People’s Hospital, School of Medicine, Tongji University, Shanghai 200434, China
| | - Enduo Feng
- Translational Research Institute of Brain and Brain-Like Intelligence, Shanghai Key Laboratory of Anesthesiology and Brain Functional Modulation, Clinical Research Center for Anesthesiology and Perioperative Medicine, Department of Anesthesiology and Perioperative Medicine, Shanghai Fourth People’s Hospital, School of Medicine, Tongji University, Shanghai 200434, China
| | - Huanxin Yin
- Translational Research Institute of Brain and Brain-Like Intelligence, Shanghai Key Laboratory of Anesthesiology and Brain Functional Modulation, Clinical Research Center for Anesthesiology and Perioperative Medicine, Department of Anesthesiology and Perioperative Medicine, Shanghai Fourth People’s Hospital, School of Medicine, Tongji University, Shanghai 200434, China
| | - Yuxin Zhang
- Translational Research Institute of Brain and Brain-Like Intelligence, Shanghai Key Laboratory of Anesthesiology and Brain Functional Modulation, Clinical Research Center for Anesthesiology and Perioperative Medicine, Department of Anesthesiology and Perioperative Medicine, Shanghai Fourth People’s Hospital, School of Medicine, Tongji University, Shanghai 200434, China
| | - Guozhong Chen
- Translational Research Institute of Brain and Brain-Like Intelligence, Shanghai Key Laboratory of Anesthesiology and Brain Functional Modulation, Clinical Research Center for Anesthesiology and Perioperative Medicine, Department of Anesthesiology and Perioperative Medicine, Shanghai Fourth People’s Hospital, School of Medicine, Tongji University, Shanghai 200434, China
| | - Beier Zhu
- Translational Research Institute of Brain and Brain-Like Intelligence, Shanghai Key Laboratory of Anesthesiology and Brain Functional Modulation, Clinical Research Center for Anesthesiology and Perioperative Medicine, Department of Anesthesiology and Perioperative Medicine, Shanghai Fourth People’s Hospital, School of Medicine, Tongji University, Shanghai 200434, China
| | - Xuezheng Yue
- School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Haiguang Zhang
- Rapid Manufacturing Engineering Center, School of Mechatronical Engineering and Automation, Shanghai University, Shanghai 200444, China
- Shanghai Key Laboratory of Intelligent Manufacturing and Robotics, Shanghai University, Shanghai 200072, China
| | - Qiong Liu
- Translational Research Institute of Brain and Brain-Like Intelligence, Shanghai Key Laboratory of Anesthesiology and Brain Functional Modulation, Clinical Research Center for Anesthesiology and Perioperative Medicine, Department of Anesthesiology and Perioperative Medicine, Shanghai Fourth People’s Hospital, School of Medicine, Tongji University, Shanghai 200434, China
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Lize Xiong
- Translational Research Institute of Brain and Brain-Like Intelligence, Shanghai Key Laboratory of Anesthesiology and Brain Functional Modulation, Clinical Research Center for Anesthesiology and Perioperative Medicine, Department of Anesthesiology and Perioperative Medicine, Shanghai Fourth People’s Hospital, School of Medicine, Tongji University, Shanghai 200434, China
| |
Collapse
|
5
|
Jin J, Li H, Chen Z, Liu Q, Chen J, Tao Z, Hong X, Ding Y, Zhou Y, Chen A, Zhang X, Lv K, Zhu L, Zhu S. Endocytosis-mediated healing: recombinant human collagen type III chain-induced wound healing for scar-free recovery. Regen Biomater 2025; 12:rbae149. [PMID: 40124986 PMCID: PMC11930350 DOI: 10.1093/rb/rbae149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2024] [Revised: 11/03/2024] [Accepted: 11/17/2024] [Indexed: 03/25/2025] Open
Abstract
Scar formation can be effectively prevented when the proportion of collagen type I (Col I)/type III (Col III) is reduced. Unlike Col III, recombinant human collagen type III chain (RHC III chain) does not possess a triple helical structure. This study aimed to elucidate the capacity of fibroblasts to uptake RHC III chain, reduce the Col I/Col III ratio and determine its effects on wound healing and scar. RHC III chain demonstrates qualified cell compatibility. In cell experiments, immunofluorescence and western blot (WB) analyses revealed an increase in the polyhistidine tag level, indicating that RHC III chain in internalized by these cells. Transmission electron microscopy showed increased intracellular phagocytic activity, indicating that RHC III chain enters fibroblasts by endocytosis. The immunofluorescence and WB showed that Col III synthesis enhanced, and Col I/Col III ratio reduced. However, the polyhistidine tag disappeared with time, indicating that RHC III chain degraded within cells and then synthesized into Col III. The content of newly synthesized Col III increases, but real-time fluorescence quantitative showed a decrease in Col III related gene content suggests the formation of negative feedback. However, due to the sufficient raw materials, the amount of Col III synthesis is still increasing, leading to the reduction of the ratio of type I collagen/type III collagen, which beneficial to wound healing and reduce scar hyperplasia. In animal experiments, the SD rat full-thickness skin defect model of wound suggests that RHC III chain also takes effect through endocytosis and ultimately promotes wound healing. The rabbit ear scar model suggests that RHC III chain inhibits scar proliferation by reducing the ratio of Col I/Col III. In summary, RHC III chain was endocytosed by fibroblasts to promote native Col III synthesis, as well as promote wound healing and reduce scar hyperplasia.
Collapse
Affiliation(s)
- Jian Jin
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
- Shanghai Depeac Biotechnology Co., Ltd, Shanghai 200444, China
| | - Haihang Li
- Jiangsu Chuangjian Medical Technology Co., Ltd, Changzhou 213100, China
| | - Zhengli Chen
- Department of Burn Surgery, Changhai Hospital, The Naval Medical University, Shanghai 200433, China
| | - Qingsong Liu
- Department of Burn Surgery, Changhai Hospital, The Naval Medical University, Shanghai 200433, China
| | - Jiqiu Chen
- Department of Burn Surgery, Changhai Hospital, The Naval Medical University, Shanghai 200433, China
| | - Zihan Tao
- Department of Burn Surgery, Changhai Hospital, The Naval Medical University, Shanghai 200433, China
| | - Xudong Hong
- Department of Burns and Plastic Surgery, 903rd Hospital of PLA, Hangzhou 310012, China
| | - Yinjia Ding
- Department of Burns and Plastic Surgery, 903rd Hospital of PLA, Hangzhou 310012, China
| | - Yue Zhou
- Department of Burns and Plastic Surgery, 903rd Hospital of PLA, Hangzhou 310012, China
| | - Aifen Chen
- Department of Burns and Plastic Surgery, 903rd Hospital of PLA, Hangzhou 310012, China
| | - Xudong Zhang
- Department of Burns and Plastic Surgery, 903rd Hospital of PLA, Hangzhou 310012, China
| | - Kaiyang Lv
- Department of Plastic Surgery, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200092, China
| | - Liangliang Zhu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Shihui Zhu
- Department of Burns and Plastic Surgery, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, China
| |
Collapse
|
6
|
Chen W, Chen M, Chen S, Wang S, Huang Z, Zhang L, Wu J, Peng W, Li H, Wen F. Decellularization of fish tissues for tissue engineering and regenerative medicine applications. Regen Biomater 2024; 12:rbae138. [PMID: 39776859 PMCID: PMC11703550 DOI: 10.1093/rb/rbae138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2024] [Revised: 10/20/2024] [Accepted: 11/17/2024] [Indexed: 01/11/2025] Open
Abstract
Decellularization is the process of obtaining acellular tissues with low immunogenic cellular components from animals or plants while maximizing the retention of the native extracellular matrix structure, mechanical integrity and bioactivity. The decellularized tissue obtained through the tissue decellularization technique retains the structure and bioactive components of its native tissue; it not only exhibits comparatively strong mechanical properties, low immunogenicity and good biocompatibility but also stimulates in situ neovascularization at the implantation site and regulates the polarization process of recruited macrophages, thereby promoting the regeneration of damaged tissue. Consequently, many commercial products have been developed as promising therapeutic strategies for the treatment of different tissue defects and lesions, such as wounds, dura, bone and cartilage defects, nerve injuries, myocardial infarction, urethral strictures, corneal blindness and other orthopedic applications. Recently, there has been a growing interest in the decellularization of fish tissues because of the abundance of sources, less religious constraints and risks of zoonosis transmission between mammals. In this review, we provide a complete overview of the state-of-the-art decellularization of fish tissues, including the organs and methods used to prepare acellular tissues. We enumerated common decellularized fish tissues from various fish organs, such as skin, scale, bladder, cartilage, heart and brain, and elaborated their different processing methods and tissue engineering applications. Furthermore, we presented the perspectives of (i) the future development direction of fish tissue decellularization technology, (ii) expanding the sources of decellularized tissue and (iii) innovating decellularized tissue bio-inks for 3D bioprinting to unleash the great potential of decellularized tissue in tissue engineering and regenerative medicine applications.
Collapse
Affiliation(s)
- Wenhui Chen
- Yuhuan People’s Hospital, Taizhou, Zhejiang 317600, China
| | - Mengshi Chen
- Key Laboratory of Biomaterials and Biofabrication for Tissue Engineering, Gannan Medical University, Ganzhou, Jiangxi 341000, China
| | - Siyi Chen
- Zhejiang Top-Medical Medical Dressing Co. Ltd, Wenzhou, Zhejiang 325025, China
| | - Siran Wang
- Zhejiang Engineering Research Centre for Tissue Repair Materials, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325001, China
| | - Zijin Huang
- Yuhuan People’s Hospital, Taizhou, Zhejiang 317600, China
| | - Lining Zhang
- Zhejiang Mariculture Research Institute, Wenzhou, Zhejiang 325005, China
| | - Jiaming Wu
- Zhejiang Engineering Research Centre for Tissue Repair Materials, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325001, China
| | - Weijie Peng
- Key Laboratory of Biomaterials and Biofabrication for Tissue Engineering, Gannan Medical University, Ganzhou, Jiangxi 341000, China
| | - Huaqiong Li
- Zhejiang Engineering Research Centre for Tissue Repair Materials, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325001, China
| | - Feng Wen
- Zhejiang Top-Medical Medical Dressing Co. Ltd, Wenzhou, Zhejiang 325025, China
- Zhejiang Engineering Research Centre for Tissue Repair Materials, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325001, China
| |
Collapse
|
7
|
Li Y, Wang J, Li Y, Luo Z, Peng T, Zou T. Nanomaterials based on hollow gold nanospheres for cancer therapy. Regen Biomater 2024; 11:rbae126. [PMID: 39664940 PMCID: PMC11631698 DOI: 10.1093/rb/rbae126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2024] [Revised: 09/30/2024] [Accepted: 10/10/2024] [Indexed: 12/13/2024] Open
Abstract
Gold nanoparticles have recently been exploited as versatile nanocarriers in diagnostic and therapeutic drug delivery for cancer nanomedicine, owing to their biocompatibility, low biotoxicity, surface modifiability and plasma optical properties. A variety of gold nanoparticles have emerged for drug delivery, mainly including gold nanorods, gold nanocages, gold nanostars, gold solid nanospheres and hollow gold nanospheres (HGNs). Among these, HGNs have widely been studied for their higher photothermal conversion efficiency, wider spectral absorption range and stronger surface-enhanced Raman scattering compared with solid gold nanospheres. Therefore, nowadays, researchers prefer to use HGNs to other metal nanocarriers, which can not only play the role of controlled-release drugs but also act as photothermal agents for tumor therapy and diagnosis, due to their properties of surface modification. Combined with the Au-S bond on the surface of HGNs, the targeted preparation is loaded to achieve precise drug delivery. With the assistance of the photothermal characteristics of HGNs themselves, the efficacy of loaded drugs in HGNs is enhanced. In addition, HGNs also have vital values in the field of bioimaging, which serve as photothermal imaging agents and Raman scattering-guided preparations due to their surface-enhanced Raman scattering properties to assist researchers in achieving the purpose of tumor diagnosis. In this review, we summarize the synthesis methods of HGNs and the recent application of HGNs-based nanomaterials in the field of cancer diagnosis and therapy. In addition, the issues to be addressed were pointed out for a bright prospect of HGNs-based nanomaterials.
Collapse
Affiliation(s)
- You Li
- State Key Laboratory of Refractories and Metallurgy, Key Laboratory of Coal Conversion & New Carbon Materials of Hubei Province, School of Chemistry and Chemical Engineering, Wuhan University of Science and Technology, Wuhan 430081, P.R. China
| | - Jing Wang
- Laboratory for Genetic Engineering of Antibodies and Functional Proteins, Beijing Institute of Pharmacology and Toxicology, Beijing 100850, P.R. China
| | - Ying Li
- State Key Laboratory of Refractories and Metallurgy, Key Laboratory of Coal Conversion & New Carbon Materials of Hubei Province, School of Chemistry and Chemical Engineering, Wuhan University of Science and Technology, Wuhan 430081, P.R. China
| | - Ziqiang Luo
- State Key Laboratory of Refractories and Metallurgy, Key Laboratory of Coal Conversion & New Carbon Materials of Hubei Province, School of Chemistry and Chemical Engineering, Wuhan University of Science and Technology, Wuhan 430081, P.R. China
| | - Tao Peng
- GEM (Wuhan) Urban Mining Industrial Group Co., Ltd, Wuhan 430415, P.R. China
| | - Tao Zou
- State Key Laboratory of Refractories and Metallurgy, Key Laboratory of Coal Conversion & New Carbon Materials of Hubei Province, School of Chemistry and Chemical Engineering, Wuhan University of Science and Technology, Wuhan 430081, P.R. China
| |
Collapse
|
8
|
Zhang W, Gao X, Zhang H, Sun G, Zhang G, Li X, Qi H, Guo J, Qin L, Shi D, Shi X, Li H, Zhang D, Guo W, Ding J. Maglev-fabricated long and biodegradable stent for interventional treatment of peripheral vessels. Nat Commun 2024; 15:7903. [PMID: 39256371 PMCID: PMC11387404 DOI: 10.1038/s41467-024-52288-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2024] [Accepted: 08/30/2024] [Indexed: 09/12/2024] Open
Abstract
While chronic limb-threatening ischemia is a serious peripheral artery disease, the lack of an appropriate stent significantly limits the potential of interventional treatment. In spite of much progress in coronary stents, little is towards peripheral stents, which are expected to be both long and biodegradable and thus require a breakthrough in core techniques. Herein, we develop a long and biodegradable stent with a length of up to 118 mm based on a metal-polymer composite material. To achieve a well-prepared homogeneous coating on a long stent during ultrasonic spraying, a magnetic levitation is employed. In vivo degradation of the stent is investigated in rabbit abdominal aorta/iliac arteries, and its preclinical safety is evaluated in canine infrapopliteal arteries. First-in-man implantation of the stent is carried out in the below-the-knee artery. The 13 months' follow-ups demonstrate the feasibility of the long and biodegradable stent in clinical applications.
Collapse
Affiliation(s)
- Wanqian Zhang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, China
- National and Local Joint Engineering Laboratory of Interventional Medical Biotechnology and System, Biotyx Medical (Shenzhen) Co., Ltd, Lifetech Scientific (Shenzhen) Co. Ltd., Shenzhen, China
| | - Xian Gao
- National and Local Joint Engineering Laboratory of Interventional Medical Biotechnology and System, Biotyx Medical (Shenzhen) Co., Ltd, Lifetech Scientific (Shenzhen) Co. Ltd., Shenzhen, China
| | - Hongjie Zhang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, China
| | - Guoyi Sun
- Department of Vascular and Endovascular Surgery, First Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Gui Zhang
- National and Local Joint Engineering Laboratory of Interventional Medical Biotechnology and System, Biotyx Medical (Shenzhen) Co., Ltd, Lifetech Scientific (Shenzhen) Co. Ltd., Shenzhen, China
| | - Xin Li
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, China
| | - Haiping Qi
- National and Local Joint Engineering Laboratory of Interventional Medical Biotechnology and System, Biotyx Medical (Shenzhen) Co., Ltd, Lifetech Scientific (Shenzhen) Co. Ltd., Shenzhen, China
| | - Jingzhen Guo
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, China
| | - Li Qin
- National and Local Joint Engineering Laboratory of Interventional Medical Biotechnology and System, Biotyx Medical (Shenzhen) Co., Ltd, Lifetech Scientific (Shenzhen) Co. Ltd., Shenzhen, China
| | - Daokun Shi
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, China
| | - Xiaoli Shi
- National and Local Joint Engineering Laboratory of Interventional Medical Biotechnology and System, Biotyx Medical (Shenzhen) Co., Ltd, Lifetech Scientific (Shenzhen) Co. Ltd., Shenzhen, China
| | - Haifeng Li
- National and Local Joint Engineering Laboratory of Interventional Medical Biotechnology and System, Biotyx Medical (Shenzhen) Co., Ltd, Lifetech Scientific (Shenzhen) Co. Ltd., Shenzhen, China
| | - Deyuan Zhang
- National and Local Joint Engineering Laboratory of Interventional Medical Biotechnology and System, Biotyx Medical (Shenzhen) Co., Ltd, Lifetech Scientific (Shenzhen) Co. Ltd., Shenzhen, China.
| | - Wei Guo
- Department of Vascular and Endovascular Surgery, First Medical Center of Chinese PLA General Hospital, Beijing, China.
| | - Jiandong Ding
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, China.
| |
Collapse
|
9
|
Wang Y, Chen X, Chen Z, Wang X, Wang H, Zhai H, Ding J, Yu L. Autophagy inhibition mediated via an injectable and NO-releasing hydrogel for amplifying the antitumor efficacy of mild magnetic hyperthermia. Bioact Mater 2024; 39:336-353. [PMID: 38827171 PMCID: PMC11140189 DOI: 10.1016/j.bioactmat.2024.05.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2024] [Revised: 05/05/2024] [Accepted: 05/17/2024] [Indexed: 06/04/2024] Open
Abstract
While mild hyperthermia holds great potential in the treatment of solid tumors, the thermal stress-triggered self-repairing autophagy significantly compromises its efficacy. To circumvent this obstacle, an injectable hydrogel (NO-Gel) composed of thermosensitive poly(ethylene glycol)-polypeptide copolymers modified with abundant NO donors on their side chains is developed. Meanwhile, ferrimagnetic Zn0.5Fe2.5O4 magnetic nanoparticles (MNPs) with high magnetic-heat conversion efficiency are synthesized and loaded into NO-Gel to obtain MNPs@NO-Gel. The MNPs@NO-Gel system exhibits a sol-gel transition upon heating, and has the ability to perform multiple magnetic hyperthermia therapy (MHT) after only one administration due to the even distribution and strong immobilization of MNPs in NO-Gel. NO can be continuously liberated from NO-Gel and this process is markedly accelerated by MHT. Additionally, MNPs@NO-Gel maintains its integrity in vivo for over one month and the released MNPs are metabolized by the spleen. After a single administration of MNPs@NO-Gel at the tumor site, three mild MHT treatments with similar effects are fulfilled, and the sufficient supply of NO effectively inhibits MHT-induced autophagic flux via blocking the formation of autophagosomes and synchronously destroying lysosomes, thereby substantially boosting the efficacy of mild MHT. As a consequence, CT-26 colon tumors are completely eliminated without causing severe side-effects.
Collapse
Affiliation(s)
- Yaoben Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Shanghai Stomatological Hospital & School of Stomatology, Fudan University, Shanghai, 200438, China
| | - Xiaobin Chen
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Shanghai Stomatological Hospital & School of Stomatology, Fudan University, Shanghai, 200438, China
| | - Zhiyong Chen
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Shanghai Stomatological Hospital & School of Stomatology, Fudan University, Shanghai, 200438, China
| | - Xin Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Shanghai Stomatological Hospital & School of Stomatology, Fudan University, Shanghai, 200438, China
| | - Hancheng Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Shanghai Stomatological Hospital & School of Stomatology, Fudan University, Shanghai, 200438, China
| | - Huajuan Zhai
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Shanghai Stomatological Hospital & School of Stomatology, Fudan University, Shanghai, 200438, China
| | - Jiandong Ding
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Shanghai Stomatological Hospital & School of Stomatology, Fudan University, Shanghai, 200438, China
| | - Lin Yu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Shanghai Stomatological Hospital & School of Stomatology, Fudan University, Shanghai, 200438, China
| |
Collapse
|
10
|
Cheng M, Xu Y, Liu W, Mu L, Lian X, Gao G, Sun L. Regulatory science promotes the translation of transcatheter tricuspid valve repair/replacement devices. Regen Biomater 2024; 11:rbae084. [PMID: 39220742 PMCID: PMC11364518 DOI: 10.1093/rb/rbae084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 06/01/2024] [Accepted: 06/08/2024] [Indexed: 09/04/2024] Open
Abstract
For patients with symptomatic and severe tricuspid regurgitation but inoperable with open surgery, transcatheter tricuspid valve intervention (TTVI) is a procedure of great clinical value. TTVI products include repair and replacement devices. TTVI products are one of the hotspots of investigation now, with different innovative biomaterials and structural designs in trials to satisfy divergent indications and reduce complications. With the emerging biomaterials, the technical difficulty of structural design will be greatly reduced, spurring further product innovation and development. The innovativeness and complexity of TTVI products have brought challenges to academia, industry, and regulatory agencies. Regulatory science provides a bridge to address these difficulties and challenges. This perspective article introduces the latest development of the TTVI products. With traditional methods, regulatory agencies face challenges in evaluating the safety and efficacy of TTVr/TTVR devices given the uncertainty of clinical use and the diversity of innovative structural design. This perspective article analyzes the regulatory challenges and discusses regulatory science that can be developed to assess the safety, efficacy, quality and performance of such products: including new approaches for innovative devices, pre-review path, computer modeling and simulation, accelerated wear testing methods for transcatheter heart valves and evidence-based research. This article reveals for the first time how to apply regulatory science systematically to TTVI products, which is of great relevance to their development and translation.
Collapse
Affiliation(s)
- Maobo Cheng
- Center for Medical Device Evaluation, National Medical Products Administration, Beijing 100081, China
| | - Yun Xu
- Center for Medical Device Evaluation, National Medical Products Administration, Beijing 100081, China
| | - Wei Liu
- Center for Medical Device Evaluation, National Medical Products Administration, Beijing 100081, China
| | - Lanlan Mu
- Center for Medical Device Evaluation, National Medical Products Administration, Beijing 100081, China
| | - Xiaoqi Lian
- Guangdong-Hong Kong-Macao Greater Bay Area, Center for Medical Device Evaluation and Inspection of NMPA, Shenzhen 518045, China
| | - Guobiao Gao
- Center for Medical Device Evaluation, National Medical Products Administration, Beijing 100081, China
| | - Lei Sun
- Center for Medical Device Evaluation, National Medical Products Administration, Beijing 100081, China
| |
Collapse
|
11
|
Zhang T, Dou Y, Li Y, Luo R, Yang L, Zhang W, Wang Y, Zhang X. Design and performance of double-layered artificial chordae. Regen Biomater 2024; 11:rbae076. [PMID: 39055301 PMCID: PMC11269677 DOI: 10.1093/rb/rbae076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2024] [Revised: 05/24/2024] [Accepted: 06/08/2024] [Indexed: 07/27/2024] Open
Abstract
Surgical repair with artificial chordae replacement has emerged as a standard treatment for mitral regurgitation. Expanded polytetrafluoroethylene (ePTFE) sutures are commonly employed as artificial chordae; however, they have certain limitations, such as potential long-term rupture and undesired material/tissue response. This study introduces a novel approach to artificial chordae design, termed the New Artificial Chordae (NAC), which incorporates a double-layered structure. The NAC comprises a multi-strand braided core composed of ultra-high molecular weight polyethylene (UHMWPE) fibers as the inner core, and an outer tube made of hydrophobic porous ePTFE. Compared to traditional ePTFE sutures, NAC exhibits increased flexibility, enhanced tensile strength, longer elongation and improved fatigue resistance. Moreover, NAC exhibits a more hydrophobic surface, which contributes to enhanced hemocompatibility. The study also includes in vivo investigations conducted on animal models to evaluate the biocompatibility and functional efficacy of the artificial chordae. These experiments demonstrate the enhanced durability and biocompatibility of the NAC, characterized by improved mechanical strength, minimal tissue response and reduced thrombus formation. These findings suggest the potential application of NAC as a prosthetic chordae replacement, offering promising prospects to address the limitations associated with current artificial chordae materials and providing novel ideas and approaches for the development of sustainable and biocompatible regenerative biomaterials.
Collapse
Affiliation(s)
- Tingchao Zhang
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, Chengdu, 610065, China
- Hangzhou Valgen Medtech Co, Ltd, Hangzhou, 310052, China
| | - Yichen Dou
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, Chengdu, 610065, China
| | - Yang Li
- Hangzhou Valgen Medtech Co, Ltd, Hangzhou, 310052, China
| | - Rifang Luo
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, Chengdu, 610065, China
| | - Li Yang
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, Chengdu, 610065, China
| | - Weiwei Zhang
- Hangzhou Valgen Medtech Co, Ltd, Hangzhou, 310052, China
| | - Yunbing Wang
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, Chengdu, 610065, China
| | - Xingdong Zhang
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, Chengdu, 610065, China
| |
Collapse
|
12
|
Liu R, Wang H, Ding J. Epithelial-Mesenchymal Transition of Cancer Cells on Micropillar Arrays. ACS APPLIED BIO MATERIALS 2024; 7:3997-4006. [PMID: 38815185 DOI: 10.1021/acsabm.4c00343] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2024]
Abstract
Epithelial-mesenchymal transition (EMT) is critical for tumor invasion and many other cell-relevant processes. While much progress has been made about EMT, no report concerns the EMT of cells on topological biomaterial interfaces with significant nuclear deformation. Herein, we prepared a poly(lactide-co-glycolide) micropillar array with an appropriate dimension to enable significant deformation of cell nuclei and examined EMT of a human lung cancer epithelial cell (A549). We show that A549 cells undergo serious nuclear deformation on the micropillar array. The cells express more E-cadherin and less vimentin on the micropillar array than on the smooth surface. After transforming growth factor-β1 (TGF-β1) treatment, the expression of E-cadherin as an indicator of the epithelial phenotype is decreased and the expression of vimentin as an indicator of the mesenchymal phenotype is increased for the cells both on smooth surfaces and on micropillar arrays, indicating that EMT occurs even when the cell nuclei are deformed and the culture on the micropillar array more enhances the expression of vimentin. Expression of myosin phosphatase targeting subunit 1 is reduced in the cells on the micropillar array, possibly affecting the turnover of myosin light chain phosphorylation and actin assembly; this makes cells on the micropillar array prefer the epithelial-like phenotype and more sensitive to TGF-β1. Overall, the micropillar array exhibits a promoting effect on the EMT.
Collapse
Affiliation(s)
- Ruili Liu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Hongyu Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Jiandong Ding
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| |
Collapse
|
13
|
Wang Q, Gao C, Zhai H, Peng C, Yu X, Zheng X, Zhang H, Wang X, Yu L, Wang S, Ding J. Electrospun Scaffolds are Not Necessarily Always Made of Nanofibers as Demonstrated by Polymeric Heart Valves for Tissue Engineering. Adv Healthc Mater 2024; 13:e2303395. [PMID: 38554036 DOI: 10.1002/adhm.202303395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Revised: 02/09/2024] [Indexed: 04/01/2024]
Abstract
In the last 30 years, there are ≈60 000 publications about electrospun nanofibers, but it is still unclear whether nanoscale fibers are really necessary for electrospun tissue engineering scaffolds. The present report puts forward this argument and reveals that compared with electrospun nanofibers, microfibers with diameter of ≈3 µm (named as "oligo-micro fiber") are more appropriate for tissue engineering scaffolds owing to their better cell infiltration ability caused by larger pores with available nuclear deformation. To further increase pore sizes, electrospun poly(ε-caprolactone) (PCL) scaffolds are fabricated using latticed collectors with meshes. Fiber orientation leads to sufficient mechanical strength albeit increases porosity. The latticed scaffolds exhibit good biocompatibility and improve cell infiltration. Under aortic conditions in vitro, the performances of latticed scaffolds are satisfactory in terms of the acute systolic hemodynamic functionality, except for the higher regurgitation fraction caused by the enlarged pores. This hierarchical electrospun scaffold with sparse fibers in macropores and oligo-micro fibers in filaments provides new insights into the design of tissue engineering scaffolds, and tissue engineering may provide living heart valves with regenerative capabilities for patients with severe valve disease in the future.
Collapse
Affiliation(s)
- Qunsong Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| | - Caiyun Gao
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| | - Huajuan Zhai
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| | - Chen Peng
- Institute for Biomechanics, Department of Aeronautics and Astronautics, Fudan University, Shanghai, 200433, China
| | - Xiaoye Yu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| | - Xiaofan Zheng
- Institute for Biomechanics, Department of Aeronautics and Astronautics, Fudan University, Shanghai, 200433, China
| | - Hongjie Zhang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| | - Xin Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| | - Lin Yu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| | - Shengzhang Wang
- Institute for Biomechanics, Department of Aeronautics and Astronautics, Fudan University, Shanghai, 200433, China
| | - Jiandong Ding
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| |
Collapse
|
14
|
Karadeli HH, Kuram E. Single Component Polymers, Polymer Blends, and Polymer Composites for Interventional Endovascular Embolization of Intracranial Aneurysms. Macromol Biosci 2024; 24:e2300432. [PMID: 37992206 DOI: 10.1002/mabi.202300432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 11/03/2023] [Indexed: 11/24/2023]
Abstract
Intracranial aneurysm is the abnormal focal dilation in brain arteries. When untreated, it can enlarge to rupture points and account for subarachnoid hemorrhage cases. Intracranial aneurysms can be treated by blocking the flow of blood to the aneurysm sac with clipping of the aneurysm neck or endovascular embolization with embolics to promote the formation of the thrombus. Coils or an embolic device are inserted endovascularly into the aneurysm via a micro-catheter to fill the aneurysm. Many embolization materials have been developed. An embolization coil made of soft and thin platinum wire called the "Guglielmi detachable coil" (GDC) enables safer treatment for brain aneurysms. However, patients may experience aneurysm recurrence because of incomplete coil filling or compaction over time. Unsatisfactory recanalization rates and incomplete occlusion are the drawbacks of endovascular embolization. So, the fabrication of new medical devices with less invasive surgical techniques is mandatory to enhance the long-term therapeutic performance of existing endovascular procedures. For this aim, the current article reviews polymeric materials including blends and composites employed for embolization of intracranial aneurysms. Polymeric materials used in embolic agents, their advantages and challenges, results of the strategies used to overcome treatment, and results of clinical experiences are summarized and discussed.
Collapse
Affiliation(s)
- Hasan Hüseyin Karadeli
- Department of Neurology, Istanbul Medeniyet University Göztepe Prof. Dr. Süleyman Yalçın City Hospital, Istanbul, 34722, Turkey
| | - Emel Kuram
- Department of Mechanical Engineering, Gebze Technical University, Kocaeli, 41400, Turkey
| |
Collapse
|
15
|
Yu X, Wang P, Gao J, Fu Y, Wang Q, Chen J, Chen S, Ding J. Wet 3D printing of biodegradable porous scaffolds to enable room-temperature deposition modeling of polymeric solutions for regeneration of articular cartilage. Biofabrication 2024; 16:035007. [PMID: 38569492 DOI: 10.1088/1758-5090/ad3a12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2023] [Accepted: 04/03/2024] [Indexed: 04/05/2024]
Abstract
Tissue engineering has emerged as an advanced strategy to regenerate various tissues using different raw materials, and thus it is desired to develop more approaches to fabricate tissue engineering scaffolds to fit specific yet very useful raw materials such as biodegradable aliphatic polyester like poly (lactide-co-glycolide) (PLGA). Herein, a technique of 'wet 3D printing' was developed based on a pneumatic extrusion three-dimensional (3D) printer after we introduced a solidification bath into a 3D printing system to fabricate porous scaffolds. The room-temperature deposition modeling of polymeric solutions enabled by our wet 3D printing method is particularly meaningful for aliphatic polyester, which otherwise degrades at high temperature in classic fuse deposition modeling. As demonstration, we fabricated a bilayered porous scaffold consisted of PLGA and its mixture with hydroxyapatite for regeneration of articular cartilage and subchondral bone. Long-termin vitroandin vivodegradation tests of the scaffolds were carried out up to 36 weeks, which support the three-stage degradation process of the polyester porous scaffold and suggest faster degradationin vivothanin vitro. Animal experiments in a rabbit model of articular cartilage injury were conducted. The efficacy of the scaffolds in cartilage regeneration was verified through histological analysis, micro-computed tomography (CT) and biomechanical tests, and the influence of scaffold structures (bilayerversussingle layer) onin vivotissue regeneration was examined. This study has illustrated that the wet 3D printing is an alternative approach to biofabricate tissue engineering porous scaffolds based on biodegradable polymers.
Collapse
Affiliation(s)
- Xiaoye Yu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, People's Republic of China
| | - Peng Wang
- Department of Sports Medicine, Huashan Hospital & State Key Laboratory of Molecular Engineering of Polymers, Fudan University, Shanghai 200040, People's Republic of China
| | - Jingming Gao
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, People's Republic of China
| | - Ye Fu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, People's Republic of China
| | - Qunsong Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, People's Republic of China
| | - Jun Chen
- Department of Sports Medicine, Huashan Hospital & State Key Laboratory of Molecular Engineering of Polymers, Fudan University, Shanghai 200040, People's Republic of China
| | - Shiyi Chen
- Department of Sports Medicine, Huashan Hospital & State Key Laboratory of Molecular Engineering of Polymers, Fudan University, Shanghai 200040, People's Republic of China
| | - Jiandong Ding
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, People's Republic of China
| |
Collapse
|
16
|
Shi D, Kang Y, Jiang Z, Li X, Zhang H, Wang Q, Guo J, Jiang H, Luo Q, Ding J. Hybrid interpenetrating network of polyester coronary stent with tunable biodegradation and mechanical properties. Biomaterials 2024; 304:122411. [PMID: 38061184 DOI: 10.1016/j.biomaterials.2023.122411] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 11/20/2023] [Accepted: 11/26/2023] [Indexed: 12/30/2023]
Abstract
Poly(l-lactide) (PLLA) is an important candidate raw material of the next-generation biodegradable stent for percutaneous coronary intervention, yet how to make a polyester stent with sufficient mechanical strength and relatively fast biodegradation gets to be a dilemma. Herein, we put forward a hybrid interpenetrating network (H-IPN) strategy to resolve this dilemma. As such, we synthesize a multi-functional biodegradable macromer of star-like poly(d,l-lactide-co-ɛ-caprolactone) with six acrylate end groups, and photoinitiate it, after mixing with linear PLLA homopolymer, to trigger the free radical polymerization. The resultant crosslinked polymer blend is different from the classic semi-interpenetrating network, and partial chemical crosslinking occurs between the linear polymer and the macromer network. Combined with the tube blow molding and the postprocessing laser cutting, we fabricate a semi-crosslinked-polyester biodegradable coronary stent composed of H-IPN, which includes a physical network of polyester spherulites and a chemical crosslinking network of copolyester macromers and a part of homopolymers. Compared with the currently main-stream PLLA stent in research, this H-IPN stent realizes a higher and more appropriate biodegradation rate while maintaining sufficient radial strength. A series of polymer chemistry, polymer physics, polymer processing, and in vitro and in vivo biological assessments of medical devices have been made to examine the H-IPN material. The interventional implanting of the H-IPN stent into aorta abdominalis of rabbits and the follow-ups to 12 months have confirmed the safety and effectiveness.
Collapse
Affiliation(s)
- Daokun Shi
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| | - Yahong Kang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China; Shanghai Key Laboratory of Interventional Medical Devices and Equipment, Shanghai MicroPort Medical Group Co., Ltd, Shanghai, 201203, China
| | - Zailai Jiang
- Shanghai Key Laboratory of Interventional Medical Devices and Equipment, Shanghai MicroPort Medical Group Co., Ltd, Shanghai, 201203, China
| | - Xin Li
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| | - Hongjie Zhang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| | - Qunsong Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| | - Jingzhen Guo
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| | - Hongyan Jiang
- Shanghai Key Laboratory of Interventional Medical Devices and Equipment, Shanghai MicroPort Medical Group Co., Ltd, Shanghai, 201203, China.
| | - Qiyi Luo
- Shanghai Key Laboratory of Interventional Medical Devices and Equipment, Shanghai MicroPort Medical Group Co., Ltd, Shanghai, 201203, China
| | - Jiandong Ding
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China.
| |
Collapse
|
17
|
Zhang H, Li X, Qu Z, Zhang W, Wang Q, Cao D, Wang Y, Wang X, Wang Y, Yu L, Ding J. Effects of serum proteins on corrosion rates and product bioabsorbability of biodegradable metals. Regen Biomater 2023; 11:rbad112. [PMID: 38173765 PMCID: PMC10761199 DOI: 10.1093/rb/rbad112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Revised: 12/03/2023] [Accepted: 12/08/2023] [Indexed: 01/05/2024] Open
Abstract
Corrodible metals are the newest kind of biodegradable materials and raise a new problem of the corrosion products. However, the removal of the precipitated products has been unclear and even largely ignored in publications. Herein, we find that albumin, an abundant macromolecule in serum, enhances the solubility of corrosion products of iron in blood mimetic Hank's solution significantly. This is universal for other main biodegradable metals such as magnesium, zinc and polyester-coated iron. Albumin also influences corrosion rates in diverse trends in Hank's solution and normal saline. Based on quantitative study theoretically and experimentally, both the effects on corrosion rates and soluble fractions are interpreted by a unified mechanism, and the key factor leading to different corrosion behaviors in corrosion media is the interference of albumin to the Ca/P passivation layer on the metal surface. This work has illustrated that the interactions between metals and media macromolecules should be taken into consideration in the design of the next-generation metal-based biodegradable medical devices in the formulism of precision medicine. The improved Hank's solution in the presence of albumin and with a higher content of initial calcium salt is suggested to access biodegradable metals potentially for cardiovascular medical devices, where the content of calcium salt is calculated after consideration of chelating of calcium ions by albumin, resulting in the physiological concentration of free calcium ions.
Collapse
Affiliation(s)
- Hongjie Zhang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Xin Li
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Zehua Qu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Wanqian Zhang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Qunsong Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Dinglingge Cao
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Yaoben Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Xin Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Yang Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Lin Yu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Jiandong Ding
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| |
Collapse
|
18
|
Hong X, Tian G, Zhu Y, Ren T. Exogeneous metal ions as therapeutic agents in cardiovascular disease and their delivery strategies. Regen Biomater 2023; 11:rbad103. [PMID: 38173776 PMCID: PMC10761210 DOI: 10.1093/rb/rbad103] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Revised: 10/26/2023] [Accepted: 11/11/2023] [Indexed: 01/05/2024] Open
Abstract
Metal ions participate in many metabolic processes in the human body, and their homeostasis is crucial for life. In cardiovascular diseases (CVDs), the equilibriums of metal ions are frequently interrupted, which are related to a variety of disturbances of physiological processes leading to abnormal cardiac functions. Exogenous supplement of metal ions has the potential to work as therapeutic strategies for the treatment of CVDs. Compared with other therapeutic drugs, metal ions possess broad availability, good stability and safety and diverse drug delivery strategies. The delivery strategies of metal ions are important to exert their therapeutic effects and reduce the potential toxic side effects for cardiovascular applications, which are also receiving increasing attention. Controllable local delivery strategies for metal ions based on various biomaterials are constantly being designed. In this review, we comprehensively summarized the positive roles of metal ions in the treatment of CVDs from three aspects: protecting cells from oxidative stress, inducing angiogenesis, and adjusting the functions of ion channels. In addition, we introduced the transferability of metal ions in vascular reconstruction and cardiac tissue repair, as well as the currently available engineered strategies for the precise delivery of metal ions, such as integrated with nanoparticles, hydrogels and scaffolds.
Collapse
Affiliation(s)
- Xiaoqian Hong
- Department of Cardiology of the Second Affiliated Hospital and State Key Laboratory of Transvascular Implantation Devices, Cardiovascular Key Laboratory of Zhejiang Province, Zhejiang University School of Medicine, Hangzhou 310009, China
| | - Geer Tian
- Department of Cardiology of the Second Affiliated Hospital and State Key Laboratory of Transvascular Implantation Devices, Cardiovascular Key Laboratory of Zhejiang Province, Zhejiang University School of Medicine, Hangzhou 310009, China
- Binjiang Institute of Zhejiang University, Hangzhou 310053, China
| | - Yang Zhu
- Binjiang Institute of Zhejiang University, Hangzhou 310053, China
- MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou 310027, China
| | - Tanchen Ren
- Department of Cardiology of the Second Affiliated Hospital and State Key Laboratory of Transvascular Implantation Devices, Cardiovascular Key Laboratory of Zhejiang Province, Zhejiang University School of Medicine, Hangzhou 310009, China
| |
Collapse
|
19
|
Stonko DP, Edwards J, Abdou H, Treffalls RN, Walker P, DeMartino RR, Mendes BC, Hicks CW, Morrison JJ. Thoracic Endovascular Aortic RepairAcutely Augments Left Ventricular Biomechanics in An Animal Model: A Mechanism for Postoperative Heart Failure and Hypertension. Ann Vasc Surg 2023; 97:18-26. [PMID: 37068623 PMCID: PMC10754260 DOI: 10.1016/j.avsg.2023.04.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 03/27/2023] [Accepted: 04/05/2023] [Indexed: 04/19/2023]
Abstract
BACKGROUND Thoracic aortic stent grafts are thought to decrease aortic compliance and may contribute to hypertension and heart failure after thoracic endovascular aortic repair (TEVAR). Left ventricular (LV) biomechanics immediately after TEVAR, however, have not been quantified. Pressure-volume (PV) loop analysis provides gold-standard LV functional information. The aim of this study is to use an LV PV loop catheter and analysis to characterize the LV biomechanics before and acutely after TEVAR. METHODS Anesthetized Yorkshire swine (N = 6) were percutaneously instrumented with an LV PV loop catheter. A 20 mm × 10 cm stent graft was deployed distal to the left subclavian via the femoral artery under fluoroscopy. Cardiac biomechanics were assessed before and after TEVAR. As a sensitivity analysis, inferior vena cava occlusion with PV loop assessment was performed pre and post-TEVAR in 1 animal to obtain preload and afterload-independent end-systolic and end-diastolic PV relationships (ESPVR and EDPVR). RESULTS All animals underwent successful instrumentation and TEVAR. Post-TEVAR, all 6 animals had higher mean LV ESP (106 vs. 118 mm Hg, P = 0.04), with no change in the EDPVR. inferior vena cava occlusion also moved the ESPVR curve upward and leftward, indicating increased LV work per unit time. There was no augmentation of EDPVR following TEVAR (P > 0.05). Postmortem exams in all animals revealed appropriate stent placement and no technical complications. CONCLUSIONS TEVAR was associated with an acute increase in LV end-systolic pressure and shift in the ESPVR, indicating increased ventricular work. This data provides potential mechanistic insights into the development of post-TEVAR hypertension and heart failure. Future stent graft innovation should focus on minimizing the changes in cardiac physiology.
Collapse
Affiliation(s)
- David P Stonko
- Department of Surgery, The Johns Hopkins Hospital, Baltimore, MD; R. Adams Cowley Shock Trauma Center, University of Maryland, Baltimore, MD
| | - Joseph Edwards
- R. Adams Cowley Shock Trauma Center, University of Maryland, Baltimore, MD
| | - Hossam Abdou
- R. Adams Cowley Shock Trauma Center, University of Maryland, Baltimore, MD
| | | | - Patrick Walker
- R. Adams Cowley Shock Trauma Center, University of Maryland, Baltimore, MD
| | | | - Bernardo C Mendes
- Divison of Vascular and Endovascular Surgery, Mayo Clinic, Rochester, MN
| | - Caitlin W Hicks
- Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, The Johns Hopkins Hospital, Baltimore, MD
| | | |
Collapse
|
20
|
Guo W, Cao D, Rao W, Sun T, Wei Y, Wang Y, Yu L, Ding J. Achieving Long-Acting Local Analgesia Using an Intelligent Hydrogel Encapsulated with Drug and pH Regulator. ACS APPLIED MATERIALS & INTERFACES 2023; 15:42113-42129. [PMID: 37639647 DOI: 10.1021/acsami.3c03149] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/31/2023]
Abstract
Local anesthetics are important for the treatment of postoperative pain. Since a single injection of the solution of a drug such as bupivacaine (BUP) works only for a few hours, it is much required to develop a long-term injectable formulation that maintains its efficacy for more than 1 day. Herein, an intelligent copolymer hydrogel loaded with BUP microcrystals was invented. The biodegradable block copolymer was synthesized by us and composed of a central hydrophilic poly(ethylene glycol) (PEG) block and two hydrophobic poly(lactide-co-glycolide) (PLGA) blocks. The aqueous system of the amphiphilic copolymer underwent a sol-gel transition between room temperature and body temperature and, thus, physically gelled after injection. Considering the decrease of solubility of BUP with the increase of pH and the internal acidic environment due to the hydrolysis of PLGA, calcium carbonate (CaCO3) powder was introduced as a pH regulator. Then, the internal pH was found to be nearly neutral and many BUP microcrystals were dispersed in the gel network. In this way, BUP had achieved a sustained release out of the thermogel. The maximum possible effect (MPE) in a rat sciatic nerve blockade model was used to describe the sensory blockade effect. In vivo analgesic effects evaluated with a hot plate experiment of rats demonstrated that the thermogel encapsulated with BUP microcrystal and CaCO3 powder significantly prolonged analgesia up to 44 h, the duration time with respect to 50% MPE. The intramuscularly injected implant exhibited biocompatibility in histological analyses. Besides, the untreated leg of the rats was not influenced by the treated leg, indicating no obvious systematic anesthesia of this hydrogel formulation. Such an intelligent and composite formulation represents a potential strategy for long-acting analgesia therapy.
Collapse
Affiliation(s)
- Wen Guo
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Dinglingge Cao
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Weihan Rao
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Tao Sun
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Yiman Wei
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Yang Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Lin Yu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Jiandong Ding
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| |
Collapse
|
21
|
Chen Z, Chen Y, Wang Y, Deng J, Wang X, Wang Q, Liu Y, Ding J, Yu L. Polyetheretherketone implants with hierarchical porous structure for boosted osseointegration. Biomater Res 2023; 27:61. [PMID: 37370127 DOI: 10.1186/s40824-023-00407-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 06/19/2023] [Indexed: 06/29/2023] Open
Abstract
BACKGROUND Good osseointegration is the key to the long-term stability of bone implants. Thermoplastic polyetheretherketone (PEEK) has been widely used in orthopedics; however, its inherent biological inertia causes fibrous tissue to wrap its surface, which leads to poor osseointegration and thus greatly limits its clinical applications. METHODS Herein, we developed a facile yet effective surface modification strategy. A commonly used sulfonation coupled with "cold pressing" treatment in the presence of porogenic agent formed a three-dimensional hierarchical porous structure on PEEK surface. Subsequently, the effects of porous surface on the in vitro adhesion, proliferation and differentiation of rat bone marrow-derived mesenchymal stem cells (BMSCs) were evaluated. Finally, the osteoinduction and osseointegration of surface-porous PEEK implant were examined in the rat distal femoral defect model. RESULTS In vitro results showed that the surface modification did not significantly affect the mechanical performance and cytocompatibility of PEEK substance, and the porous structure on the modified PEEK substrate provided space for cellular ingrowth and enhanced osteogenic differentiation and mineralization of BMSCs. In vivo tests demonstrated that the surface-porous PEEK implant could effectively promote new bone formation and had higher bone-implant contact rate, thereby achieving good bone integration with the surrounding host bone. In addition, this modification technique was also successfully demonstrated on a medical PEEK interbody fusion cage. CONCLUSION The present study indicates that topological morphology plays a pivotal role in determining implant osseointegration and this facile and effective modification strategy developed by us is expected to achieve practical applications quickly.
Collapse
Affiliation(s)
- Zhiyong Chen
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Shanghai Stomatological Hospital & School of Stomatology, Fudan University, Shanghai, 200438, China
| | - Yu Chen
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Shanghai Stomatological Hospital & School of Stomatology, Fudan University, Shanghai, 200438, China
| | - Yang Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Shanghai Stomatological Hospital & School of Stomatology, Fudan University, Shanghai, 200438, China
| | - JiaJia Deng
- Department of Orthodontics, Shanghai Stomatological Hospital & School of Stomatology, Shanghai Key Laboratory of Craniomaxillofacial Development and Diseases, Fudan University, Shanghai, 200001, China
| | - Xin Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Shanghai Stomatological Hospital & School of Stomatology, Fudan University, Shanghai, 200438, China
| | - Qingqing Wang
- Department of Orthopaedic Surgery, Sir Run Run Shaw Hospital, Medical College of Zhejiang University, Hangzhou, 310016, Zhejiang, China
| | - Yuehua Liu
- Department of Orthodontics, Shanghai Stomatological Hospital & School of Stomatology, Shanghai Key Laboratory of Craniomaxillofacial Development and Diseases, Fudan University, Shanghai, 200001, China
| | - Jiandong Ding
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Shanghai Stomatological Hospital & School of Stomatology, Fudan University, Shanghai, 200438, China
| | - Lin Yu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Shanghai Stomatological Hospital & School of Stomatology, Fudan University, Shanghai, 200438, China.
| |
Collapse
|
22
|
Vidakis N, Petousis M, Moutsopoulou A, Papadakis V, Spiridaki M, Mountakis N, Charou C, Tsikritzis D, Maravelakis E. Nanocomposites with Optimized Polytetrafluoroethylene Content as a Reinforcement Agent in PA12 and PLA for Material Extrusion Additive Manufacturing. Polymers (Basel) 2023; 15:2786. [PMID: 37447432 DOI: 10.3390/polym15132786] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 06/12/2023] [Accepted: 06/21/2023] [Indexed: 07/15/2023] Open
Abstract
Herein, polytetrafluoroethylene (PTFE) is evaluated as a reinforcement agent in material extrusion (MEX) additive manufacturing (AM), aiming to develop nanocomposites with enhanced mechanical performance. Loadings up to 4.0 wt.% were introduced as fillers of polylactic acid (PLA) and polyamide 12 (PA12) matrices. Filaments for MEX AM were prepared to produce corresponding 3D-printed samples. For the thorough characterization of the nanocomposites, a series of standardized mechanical tests were followed, along with AFM, TGA, Raman spectroscopy, EDS, and SEM analyses. The results showed an improved mechanical response for filler concentrations between 2.0 and 3.0 wt.%. The enhancement for the PLA/PTFE 2.0 wt.% in the tensile strength reached 21.1% and the modulus of elasticity 25.5%; for the PA12/PTFE 3.0 wt.%, 34.1%, and 41.7%, respectively. For PLA/PTFE 2.0 wt.%, the enhancement in the flexural strength reached 57.6% and the modulus of elasticity 25.5%; for the PA12/PTFE 3.0 wt.%, 14.7%, and 17.2%, respectively. This research enables the ability to deploy PTFE as a reinforcement agent in the PA12 and PLA thermoplastic engineering polymers in the MEX AM process, expanding the potential applications.
Collapse
Affiliation(s)
- Nectarios Vidakis
- Department of Mechanical Engineering, Hellenic Mediterranean University, 71410 Heraklion, Greece
| | - Markos Petousis
- Department of Mechanical Engineering, Hellenic Mediterranean University, 71410 Heraklion, Greece
| | - Amalia Moutsopoulou
- Department of Mechanical Engineering, Hellenic Mediterranean University, 71410 Heraklion, Greece
| | - Vassilis Papadakis
- Department of Industrial Design and Production Engineering, University of West Attica, 12244 Athens, Greece
- Institute of Electronic Structure and Laser, Foundation for Research and Technology-Hellas, N. Plastira 100m, 70013 Heraklion, Greece
| | - Mariza Spiridaki
- Department of Mechanical Engineering, Hellenic Mediterranean University, 71410 Heraklion, Greece
| | - Nikolaos Mountakis
- Department of Mechanical Engineering, Hellenic Mediterranean University, 71410 Heraklion, Greece
| | - Chrysa Charou
- Department of Mechanical Engineering, Hellenic Mediterranean University, 71410 Heraklion, Greece
| | - Dimitris Tsikritzis
- Department of Electrical & Computer Engineering, Hellenic Mediterranean University, 71410 Heraklion, Greece
| | - Emmanuel Maravelakis
- Department of Electronic Engineering, Hellenic Mediterranean University (HMU), 73133 Chania, Greece
| |
Collapse
|
23
|
Wang G, Feng Y, Gao C, Zhang X, Wang Q, Zhang J, Zhang H, Wu Y, Li X, Wang L, Fu Y, Yu X, Zhang D, Liu J, Ding J. Biaxial stretching of polytetrafluoroethylene in industrial scale to fabricate medical ePTFE membrane with node-fibril microstructure. Regen Biomater 2023; 10:rbad056. [PMID: 37397871 PMCID: PMC10310521 DOI: 10.1093/rb/rbad056] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 05/19/2023] [Accepted: 05/25/2023] [Indexed: 07/04/2023] Open
Abstract
Expanded polytetrafluoroethylene (ePTFE) is promising in biomedical fields such as covered stents and plastic surgery owing to its excellent biocompatibility and mechanical properties. However, ePTFE material prepared by the traditional biaxial stretching process is with thicker middle and thinner sides due to the bowing effect, which poses a major problem in industrial-scale fabrication. To solve this problem, we design an olive-shaped winding roller to provide the middle part of the ePTFE tape with a greater longitudinal stretching amplitude than the two sides, so as to make up for the excessive longitudinal retraction tendency of the middle part when it is transversely stretched. The as-fabricated ePTFE membrane has, as designed, uniform thickness and node-fibril microstructure. In addition, we examine the effects of mass ratio of lubricant to PTFE powder, biaxial stretching ratio and sintering temperature on the performance of the resultant ePTFE membranes. Particularly, the relation between the internal microstructure of the ePTFE membrane and its mechanical properties is revealed. Besides stable mechanical properties, the sintered ePTFE membrane exhibits satisfactory biological properties. We make a series of biological assessments including in vitro hemolysis, coagulation, bacterial reverse mutation and in vivo thrombosis, intracutaneous reactivity test, pyrogen test and subchronic systemic toxicity test; all of the results meet the relevant international standards. The muscle implantation of the sintered ePTFE membrane into rabbits indicates acceptable inflammatory reactions of our sintered ePTFE membrane fabricated on industrial scale. Such a medical-grade raw material with the unique physical form and condensed-state microstructure is expected to afford an inert biomaterial potentially for stent-graft membrane.
Collapse
Affiliation(s)
- Gang Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
- R&D Center, Lifetech Scientific (Shenzhen) Co., Ltd., Shenzhen 518057, China
- R&D Center, Lifevalve Medical Scientific Co., Ltd., Shenzhen 518057, China
| | - Yusheng Feng
- R&D Center, Lifetech Scientific (Shenzhen) Co., Ltd., Shenzhen 518057, China
| | - Caiyun Gao
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Xu Zhang
- R&D Center, Lifetech Scientific (Shenzhen) Co., Ltd., Shenzhen 518057, China
- R&D Center, Lifevalve Medical Scientific Co., Ltd., Shenzhen 518057, China
| | - Qunsong Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Jie Zhang
- R&D Center, Lifetech Scientific (Shenzhen) Co., Ltd., Shenzhen 518057, China
- R&D Center, Lifevalve Medical Scientific Co., Ltd., Shenzhen 518057, China
| | - Hongjie Zhang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Yongqiang Wu
- R&D Center, Lifetech Scientific (Shenzhen) Co., Ltd., Shenzhen 518057, China
- R&D Center, Lifevalve Medical Scientific Co., Ltd., Shenzhen 518057, China
| | - Xin Li
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Lin Wang
- R&D Center, Lifetech Scientific (Shenzhen) Co., Ltd., Shenzhen 518057, China
- R&D Center, Lifevalve Medical Scientific Co., Ltd., Shenzhen 518057, China
| | - Ye Fu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Xiaoye Yu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Deyuan Zhang
- R&D Center, Lifetech Scientific (Shenzhen) Co., Ltd., Shenzhen 518057, China
| | - Jianxiong Liu
- R&D Center, Lifetech Scientific (Shenzhen) Co., Ltd., Shenzhen 518057, China
| | - Jiandong Ding
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| |
Collapse
|
24
|
Zhang T, Dou Y, Luo R, Yang L, Zhang W, Ma K, Wang Y, Zhang X. A review of the development of interventional devices for mitral valve repair with the implantation of artificial chords. Front Bioeng Biotechnol 2023; 11:1173413. [PMID: 37334267 PMCID: PMC10272602 DOI: 10.3389/fbioe.2023.1173413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Accepted: 05/19/2023] [Indexed: 06/20/2023] Open
Abstract
Mitral regurgitation (MR) was the most common heart valve disease. Surgical repair with artificial chordal replacement had become one of the standard treatments for mitral regurgitation. Expanded polytetrafluoroethylene (ePTFE) was currently the most commonly used artificial chordae material due to its unique physicochemical and biocompatible properties. Interventional artificial chordal implantation techniques had emerged as an alternative treatment option for physicians and patients in treating mitral regurgitation. Using either a transapical or a transcatheter approach with interventional devices, a chordal replacement could be performed transcatheter in the beating heart without cardiopulmonary bypass, and the acute effect on the resolution of mitral regurgitation could be monitored in real-time by transesophageal echo imaging during the procedure. Despite the in vitro durability of the expanded polytetrafluoroethylene material, artificial chordal rupture occasionally occurred. In this article, we reviewed the development and therapeutic results of interventional devices for chordal implantation and discuss the possible clinical factors responsible for the rupture of the artificial chordal material.
Collapse
Affiliation(s)
- Tingchao Zhang
- National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu, China
- Hangzhou Valgen Medtech Co., Ltd., Hangzhou, China
| | - Yichen Dou
- National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu, China
| | - Rifang Luo
- National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu, China
| | - Li Yang
- National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu, China
| | - Weiwei Zhang
- Hangzhou Valgen Medtech Co., Ltd., Hangzhou, China
| | - Kangmu Ma
- Hangzhou Valgen Medtech Co., Ltd., Hangzhou, China
| | - Yunbing Wang
- National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu, China
| | - Xingdong Zhang
- National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu, China
| |
Collapse
|
25
|
Wei Y, Cui S, Yu L, Ding J. Degradation-Influenced/Induced Self-Assembly of Copolymers with the Combinatory Effects of Changed Molecular Weight and Dispersity. Macromolecules 2023. [DOI: 10.1021/acs.macromol.2c02309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/30/2023]
|
26
|
Rao WH, Yu L, Ding JD. Stride Strategy to Enable a Quasi-ergodic Search of Reaction Pathways Demonstrated by Ring-opening Polymerization of Cyclic Esters. CHINESE JOURNAL OF POLYMER SCIENCE 2023. [DOI: 10.1007/s10118-023-2930-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/25/2023]
|
27
|
Li X, Ding J. Establishment of coverage-mass equation to quantify the corrosion inhomogeneity and examination of medium effects on iron corrosion. Regen Biomater 2023; 10:rbad007. [PMID: 36817974 PMCID: PMC9933843 DOI: 10.1093/rb/rbad007] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2022] [Revised: 01/19/2023] [Accepted: 01/30/2023] [Indexed: 02/04/2023] Open
Abstract
Metal corrosion is important in the fields of biomedicine as well as construction and transportation etc. While most corrosion occurs inhomogeneously, there is so far no satisfactory parameter to characterize corrosion inhomogeneity. Herein, we employ the Poisson raindrop question to model the corrosion process and derive an equation to relate corrosion coverage and corrosion mass. The resultant equation is named coverage-mass equation, abbreviated as C-M equation. We also suggest corrosion mass at 50% coverage, termed as half-coverage mass M corro50%, as an inhomogeneity parameter to quantify corrosion inhomogeneity. The equation is confirmed and the half-coverage mass M corro50% is justified in our experiments of iron corrosion in five aqueous media, normal saline, phosphate-buffered saline, Hank's solution, deionized water and artificial seawater, where the former three ones are biomimetic and very important in studies of biomedical materials. The half-coverage mass M corro50% is proved to be more comprehensive and mathematically convergent than the traditional pitting factor. Iron corrosion is detected using visual observation, scanning electron microscopy with a build-in energy dispersive spectrometer, inductive coupled plasma emission spectrometry and electrochemical measurements. Both rates and inhomogeneity extents of iron corrosion are compared among the five aqueous media. The factors underlying the medium effects on corrosion rate and inhomogeneity are discussed and interpreted. Corrosion rates of iron in the five media differ about 7-fold, and half-coverage mass values differ about 300 000-fold. The fastest corrosion and the most significant inhomogeneity occur both in biomimetic media, but not the same one. The new equation (C-M equation) and the new quantity (half-coverage mass) are stimulating for dealing with a dynamic and stochastic process with global inhomogeneity including but not limited to metal corrosion. The findings are particularly meaningful for research and development of next-generation biodegradable materials.
Collapse
Affiliation(s)
- Xin Li
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | | |
Collapse
|
28
|
Wang Q, Liu Q, Gao J, He J, Zhang H, Ding J. Stereo Coverage and Overall Stiffness of Biomaterial Arrays Underly Parts of Topography Effects on Cell Adhesion. ACS APPLIED MATERIALS & INTERFACES 2023; 15:6142-6155. [PMID: 36637977 DOI: 10.1021/acsami.2c19742] [Citation(s) in RCA: 23] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Surface topography is a biophysical factor affecting cell behaviors, yet the underlying cues are still not clear. Herein, we hypothesized that stereo coverage and overall stiffness of biomaterial arrays on the scale of single cells underly parts of topography effects on cell adhesion. We fabricated a series of microarrays (micropillar, micropit, and microtube) of poly(l-lactic acid) (PLLA) using mold casting based on pre-designed templates. The characteristic sizes of array units were less than that of a single cell, and thus, each cell could sense the micropatterns with varied roughness. With human umbilical vein endothelial cells (HUVECs) as the model cell type, we examined spreading areas and cell viabilities on different surfaces. "Stereo coverage" was defined to quantify the actual cell spreading fraction on a topographic surface. Particularly in the case of high micropillars, cells were confirmed not able to touch the bottom and had to partially hang among the micropillars. Then, in our opinion, a cell sensed the overall stiffness combining the bulk stiffness of the raw material and the stiffness of the culture medium. Spreading area and single cell viability were correlated to coverage and topographic feature of the prepared microarrays in particular with the significantly protruded geometry feather. Cell traction forces exerted on micropillars were also discussed. These findings provide new insights into the surface modifications toward biomedical implants.
Collapse
Affiliation(s)
- Qunsong Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai200438, China
| | - Qingsong Liu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai200438, China
| | - Jingming Gao
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai200438, China
| | - Junhao He
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai200438, China
| | - Hongjie Zhang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai200438, China
| | - Jiandong Ding
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai200438, China
| |
Collapse
|
29
|
Gao J, Xu X, Yu X, Fu Y, Zhang H, Gu S, Cao D, Guo Q, Xu L, Ding J. Quantitatively relating magnetic resonance T1 and T2 to glycosaminoglycan and collagen concentrations mediated by penetrated contrast agents and biomacromolecule-bound water. Regen Biomater 2023; 10:rbad035. [PMID: 37206162 PMCID: PMC10191676 DOI: 10.1093/rb/rbad035] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2023] [Revised: 04/03/2023] [Accepted: 04/07/2023] [Indexed: 05/21/2023] Open
Abstract
Magnetic resonance imaging (MRI) is a promising non-invasive method to assess cartilage regeneration based on the quantitative relationship between MRI features and concentrations of the major components in the extracellular matrix (ECM). To this end, in vitro experiments are performed to investigate the relationship and reveal the underlying mechanism. A series of collagen (COL) and glycosaminoglycan (GAG) solutions at different concentrations are prepared, and T1 and T2 relaxation times are measured with or without a contrast agent (Gd-DTPA2-) by MRI. Fourier transform infrared spectrometry is also used to measure the contents of biomacromolecule-bound water and other water, allowing theoretical derivation of the relationship between biomacromolecules and the resulting T2 values. It has been revealed that the MRI signal in the biomacromolecule aqueous systems is mainly influenced by the protons in hydrogens of biomacromolecule-bound water, which we divide into inner-bound water and outer-bound water. We have also found that COL results in higher sensitivity of bound water than GAG in T2 mapping. Owing to the charge effect, GAG regulates the penetration of the contrast agent during dialysis and has a more significant effect on T1 values than COL. Considering that COL and GAG are the most abundant biomacromolecules in the cartilage, this study is particularly useful for the real-time MRI-guided assessment of cartilage regeneration. A clinical case is reported as an in vivo demonstration, which is consistent with our in vitro results. The established quantitative relation plays a critical academic role in establishing an international standard ISO/TS24560-1:2022 'Clinical evaluation of regenerative knee articular cartilage using delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) and T2 mapping' drafted by us and approved by International Standard Organization.
Collapse
Affiliation(s)
- Jingming Gao
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Xian Xu
- Correspondence address. E-mail: (X.X.); (J.D.)
| | - Xiaoye Yu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Ye Fu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Hongjie Zhang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Siyi Gu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Dinglingge Cao
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Quanyi Guo
- Institute of Orthopedics, The First Medical Center, Chinese PLA General Hospital, Beijing Key Lab of Regenerative Medicine in Orthopedics, Key Laboratory of Musculoskeletal Trauma and War Injuries of PLA, Beijing 100853, China
| | - Liming Xu
- Institute for Medical Device Control, National Institutes for Food and Drug Control, Beijing 102629, China
| | | |
Collapse
|
30
|
Cao D, Ding J. Recent advances in regenerative biomaterials. Regen Biomater 2022; 9:rbac098. [PMID: 36518879 PMCID: PMC9745784 DOI: 10.1093/rb/rbac098] [Citation(s) in RCA: 110] [Impact Index Per Article: 36.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 11/23/2022] [Accepted: 12/01/2022] [Indexed: 07/22/2023] Open
Abstract
Nowadays, biomaterials have evolved from the inert supports or functional substitutes to the bioactive materials able to trigger or promote the regenerative potential of tissues. The interdisciplinary progress has broadened the definition of 'biomaterials', and a typical new insight is the concept of tissue induction biomaterials. The term 'regenerative biomaterials' and thus the contents of this article are relevant to yet beyond tissue induction biomaterials. This review summarizes the recent progress of medical materials including metals, ceramics, hydrogels, other polymers and bio-derived materials. As the application aspects are concerned, this article introduces regenerative biomaterials for bone and cartilage regeneration, cardiovascular repair, 3D bioprinting, wound healing and medical cosmetology. Cell-biomaterial interactions are highlighted. Since the global pandemic of coronavirus disease 2019, the review particularly mentions biomaterials for public health emergency. In the last section, perspectives are suggested: (i) creation of new materials is the source of innovation; (ii) modification of existing materials is an effective strategy for performance improvement; (iii) biomaterial degradation and tissue regeneration are required to be harmonious with each other; (iv) host responses can significantly influence the clinical outcomes; (v) the long-term outcomes should be paid more attention to; (vi) the noninvasive approaches for monitoring in vivo dynamic evolution are required to be developed; (vii) public health emergencies call for more research and development of biomaterials; and (viii) clinical translation needs to be pushed forward in a full-chain way. In the future, more new insights are expected to be shed into the brilliant field-regenerative biomaterials.
Collapse
Affiliation(s)
- Dinglingge Cao
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | - Jiandong Ding
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| |
Collapse
|