1
|
Mao H, Zhang H, Luo Y, Yang J, Liu Y, Zhang S, Chen W, Li Q, Dai Z. Primary study of the relative and compound biological effectiveness model for boron neutron capture therapy based on nanodosimetry. Med Phys 2024; 51:3076-3092. [PMID: 38408025 DOI: 10.1002/mp.16998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 12/31/2023] [Accepted: 02/07/2024] [Indexed: 02/28/2024] Open
Abstract
BACKGROUND The current radiobiological model employed for boron neutron capture therapy (BNCT) treatment planning, which relies on microdosimetry, fails to provide an accurate representation the biological effects of BNCT. The precision in calculating the relative biological effectiveness (RBE) and compound biological effectiveness (CBE) plays a pivotal role in determining the therapeutic efficacy of BNCT. Therefore, this study focuses on how to improve the accuracy of the biological effects of BNCT. PURPOSE The purpose of this study is to propose new radiation biology models based on nanodosimetry to accurately assess RBE and CBE for BNCT. METHODS Nanodosimetry, rooted in ionization cluster size distributions (ICSD), introduces a novel approach to characterize radiation quality by effectively delineating RBE through the ion track structure at the nanoscale. In the context of prior research, this study presents a computational model for the nanoscale assessment of RBE and CBE. We establish a simplified model of DNA chromatin fiber using the Monte Carlo code TOPAS-nBio to evaluate the applicability of ICSD to BNCT and compute nanodosimetric parameters. RESULTS Our investigation reveals that both homogeneous and heterogeneous nanodosimetric parameters, as well as the corresponding biological model coefficients α and β, along with RBE values, exhibit variations in response to varying intracellular 10B concentrations. Notably, the nanodosimetric parameterM 1 C 2 $M_1^{{{\mathrm{C}}}_2}$ effectively captures the fluctuations in model coefficients α and RBE. CONCLUSION Our model facilitates a nanoscale analysis of BNCT, enabling predictions of nanodosimetric quantities for secondary ions as well as RBE, CBE, and other essential biological metrics related to the distribution of boron. This contribution significantly enhances the precision of RBE calculations and holds substantial promise for future applications in treatment planning.
Collapse
Affiliation(s)
- Haijun Mao
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
- School of Nuclear Science and Technology, Lanzhou University, Lanzhou, China
| | - Hui Zhang
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Ying Luo
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Jingfen Yang
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Yinuo Liu
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
- School of Future Technology, Xi'an Jiaotong University, Xi'an, Shaanxi, China
| | - Shichao Zhang
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
- School of Nuclear Science and Technology, Lanzhou University, Lanzhou, China
| | - Weiqiang Chen
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
- University of Chinese Academy of Sciences, Beijing, China
- Putian Lanhai Nuclear Medicine Research Center, Putian, China
| | - Qiang Li
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
- University of Chinese Academy of Sciences, Beijing, China
- Putian Lanhai Nuclear Medicine Research Center, Putian, China
| | - Zhongying Dai
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
- University of Chinese Academy of Sciences, Beijing, China
| |
Collapse
|
2
|
Han Y, Geng C, D-Kondo JN, Li M, Ramos-Méndez J, Altieri S, Liu Y, Tang X. Microdosimetric Analysis for Boron Neutron Capture Therapy via Monte Carlo Track Structure Simulation with Modified Lithium Cross-sections. Radiat Phys Chem Oxf Engl 1993 2023; 209:110956. [PMID: 37206625 PMCID: PMC10191410 DOI: 10.1016/j.radphyschem.2023.110956] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Boron neutron capture therapy (BNCT) is a cellular-level hadron therapy achieving therapeutic effects via the synergistic action of multiple particles, including Lithium, alpha, proton, and photon. However, evaluating the relative biological effectiveness (RBE) in BNCT remains challenging. In this research, we performed a microdosimetric calculation for BNCT using the Monte Carlo track structure (MCTS) simulation toolkit, TOPAS-nBio. This paper reports the first attempt to derive the ionization cross-sections of low-energy (>0.025 MeV/u) Lithium for MCTS simulation based on the effective charge cross-section scalation method and phenomenological double-parameter modification. The fitting parameters λ1=1.101,λ2=3.486 were determined to reproduce the range and stopping power data from the ICRU report 73. Besides, the lineal energy spectra of charged particles in BNCT were calculated, and the influence of sensitive volume (SV) size was discussed. Condensed history simulation obtained similar results with MCTS when using Micron-SV while overestimating the lineal energy when using Nano-SV. Furthermore, we found that the microscopic boron distribution can significantly affect the lineal energy for Lithium, while the effect for alpha is minimal. Similar results to the published data by PHITS simulation were observed for the compound particles and monoenergetic protons when using micron-SV. Spectra with nano-SV reflected that the different track densities and absorbed doses in the nucleus together result in the dramatic difference in the macroscopic biological response of BPA and BSH. This work and the developed methodology could impact the research fields in BNCT where understanding radiation effects is crucial, such as the treatment planning system, source evaluation, and new boron drug development.
Collapse
Affiliation(s)
- Yang Han
- Nanjing University of Aeronautics and Astronautics, Department of Nuclear Science and Technology, Nanjing, 210016, China
- Joint International Research Laboratory on Advanced Particle Therapy, Nanjing 211100, China
- University of Pavia, Department of Physics, Pavia, 27100, Italy
| | - Changran Geng
- Nanjing University of Aeronautics and Astronautics, Department of Nuclear Science and Technology, Nanjing, 210016, China
- Joint International Research Laboratory on Advanced Particle Therapy, Nanjing 211100, China
- (+86 13601582233), (+86 15380796769)
| | - J. Naoki D-Kondo
- University of California San Francisco, Department of Radiation Oncology, San Francisco, CA 94115, USA
| | - Mingzhu Li
- Nanjing University of Aeronautics and Astronautics, Department of Nuclear Science and Technology, Nanjing, 210016, China
- Joint International Research Laboratory on Advanced Particle Therapy, Nanjing 211100, China
| | - José Ramos-Méndez
- University of California San Francisco, Department of Radiation Oncology, San Francisco, CA 94115, USA
| | - Saverio Altieri
- University of Pavia, Department of Physics, Pavia, 27100, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), the section of Pavia, Pavia, 27100, Italy
| | - Yuanhao Liu
- Nanjing University of Aeronautics and Astronautics, Department of Nuclear Science and Technology, Nanjing, 210016, China
- Joint International Research Laboratory on Advanced Particle Therapy, Nanjing 211100, China
| | - Xiaobin Tang
- Nanjing University of Aeronautics and Astronautics, Department of Nuclear Science and Technology, Nanjing, 210016, China
- Joint International Research Laboratory on Advanced Particle Therapy, Nanjing 211100, China
- (+86 13601582233), (+86 15380796769)
| |
Collapse
|
3
|
Fattori S, Petringa G, Agosteo S, Bortot D, Conte V, Cuttone G, Di Fini A, Farokhi F, Mazzucconi D, Pandola L, Petrović I, Ristić-Fira A, Rosenfeld A, Weber U, Cirrone GAP. 4He dose- and track-averaged linear energy transfer: Monte Carlo algorithms and experimental verification. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac776f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2022] [Accepted: 06/09/2022] [Indexed: 11/12/2022]
Abstract
Abstract
Objective. In the present hadrontherapy scenario, there is a growing interest in exploring the capabilities of different ion species other than protons and carbons. The possibility of using different ions paves the way for new radiotherapy approaches, such as the multi-ions treatment, where radiation could vary according to target volume, shape, depth and histologic characteristics of the tumor. For these reasons, in this paper, the study and understanding of biological-relevant quantities was extended for the case of 4He ion. Approach. Geant4 Monte Carlo based algorithms for dose- and track-averaged LET (Linear Energy Transfer) calculations, were validated for 4He ions and for the case of a mixed field characterised by the presence of secondary ions from both target and projectile fragmentation. The simulated dose and track averaged LETs were compared with the corresponding dose and frequency mean values of the lineal energy,
y
D
¯
and
y
¯
F
, derived from experimental microdosimetric spectra. Two microdosimetric experimental campaigns were carried out at the Italian eye proton therapy facility of the Laboratori Nazionali del Sud of Istituto Nazionale di Fisica Nucleare (INFN-LNS, Catania, I) using two different microdosimeters: the MicroPlus probe and the nano-TEPC (Tissue Equivalent Proportional Counter). Main results. A good agreement of
L
¯
d
Total
and
L
¯
t
Total
with
y
¯
D
and
y
¯
T
experimentally measured with both microdosimetric detectors MicroPlus and nano-TEPC in two configurations: full energy and modulated 4He ion beam, was found. Significance. The results of this study certify the use of a very effective tool for the precise calculation of LET, given by a Monte Carlo approach which has the advantage of allowing detailed simulation and tracking of nuclear interactions, even in complex clinical scenarios.
Collapse
|
6
|
Bortot D, Mazzucconi D, Pola A, Fazzi A, Pullia M, Savazzi S, Colautti P, Conte V, Agosteo S. A nano-microdosimetric characterization of a therapeutic carbon ion beam at CNAO. Radiat Phys Chem Oxf Engl 1993 2020. [DOI: 10.1016/j.radphyschem.2019.108674] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|