1
|
Aldag N, Nogueira W. Psychoacoustic and electroencephalographic responses to changes in amplitude modulation depth and frequency in relation to speech recognition in cochlear implantees. Sci Rep 2024; 14:8181. [PMID: 38589483 PMCID: PMC11002021 DOI: 10.1038/s41598-024-58225-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Accepted: 03/26/2024] [Indexed: 04/10/2024] Open
Abstract
Temporal envelope modulations (TEMs) are one of the most important features that cochlear implant (CI) users rely on to understand speech. Electroencephalographic assessment of TEM encoding could help clinicians to predict speech recognition more objectively, even in patients unable to provide active feedback. The acoustic change complex (ACC) and the auditory steady-state response (ASSR) evoked by low-frequency amplitude-modulated pulse trains can be used to assess TEM encoding with electrical stimulation of individual CI electrodes. In this study, we focused on amplitude modulation detection (AMD) and amplitude modulation frequency discrimination (AMFD) with stimulation of a basal versus an apical electrode. In twelve adult CI users, we (a) assessed behavioral AMFD thresholds and (b) recorded cortical auditory evoked potentials (CAEPs), AMD-ACC, AMFD-ACC, and ASSR in a combined 3-stimulus paradigm. We found that the electrophysiological responses were significantly higher for apical than for basal stimulation. Peak amplitudes of AMFD-ACC were small and (therefore) did not correlate with speech-in-noise recognition. We found significant correlations between speech-in-noise recognition and (a) behavioral AMFD thresholds and (b) AMD-ACC peak amplitudes. AMD and AMFD hold potential to develop a clinically applicable tool for assessing TEM encoding to predict speech recognition in CI users.
Collapse
Affiliation(s)
- Nina Aldag
- Department of Otolaryngology, Hannover Medical School and Cluster of Excellence 'Hearing4all', Hanover, Germany
| | - Waldo Nogueira
- Department of Otolaryngology, Hannover Medical School and Cluster of Excellence 'Hearing4all', Hanover, Germany.
| |
Collapse
|
2
|
Maruthurkkara S, Bennett C. Development of Custom Sound® Pro software utilising big data and its clinical evaluation. Int J Audiol 2024; 63:87-98. [PMID: 36542487 DOI: 10.1080/14992027.2022.2155880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Revised: 12/01/2022] [Accepted: 12/02/2022] [Indexed: 12/24/2022]
Abstract
OBJECTIVES To inform and optimise a cochlear implant (CI) fitting software design through an analysis of big data to define array-specific comfort (C) level profiles, frequently-used MAP parameters, and the minimum number of Neural Response Telemetry thresholds (tNRT) needed to create an accurate profile. To evaluate the software's ease of use and completion time for AutoNRT®s. DESIGN MAPs analysis. Clinical study evaluating software use in creating MAPs, addressing sound-quality issues and setting patient goals. STUDY SAMPLE MAPs (N = 39,885); CI recipients (N = 47) and clinicians (N = 19). RESULTS Distinct C-level profiles were observed for lateral-wall, contour, and slim-modiolar electrode arrays. Default settings were used for most MAP parameters (13/16) except for Pulse Width, Rate, and Maxima. Nine tNRT measurements were required for an accurate C-level profile. Measurement-time of nine tNRTs via the new algorithm was comparable to five tNRTs using the previous algorithm. Nearly all (99%) clinical tasks were completed by clinicians with the first use of the software. Most CI recipients (79.5%) rated goal-setting as valuable. CONCLUSION Custom Sound Pro fitting software developed based on big data analysis incorporates a guided fitting workflow and expected fitting ranges. It helps to improve clinical efficiency, is easy to use and supports patient-centred care.
Collapse
|
3
|
Konrad S, Büchner A, Lenarz T, Paasche G. Impedance development after implantation of hybrid-L24 cochlear implant electrodes. Int J Audiol 2023; 62:1137-1144. [PMID: 36193989 DOI: 10.1080/14992027.2022.2125914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Accepted: 09/13/2022] [Indexed: 11/05/2022]
Abstract
OBJECTIVE Shorter and thinner electrodes were developed for preserving residual hearing after cochlear implantation by minimising trauma. As trauma is regarded as one of the causes of fibrous tissue formation after implantation, and increase in impedance is considered to be connected to fibrous tissue formation, the aim of the current study was to evaluate impedance development after implantation of Hybrid-L electrodes. DESIGN Impedance values were retrospectively collected from our clinical database and evaluated for all active contacts and basal, middle and apical contacts separately for up to 10 years. STUDY SAMPLES All 137 adult patients received a Hybrid-L electrode and had to be implanted for at least 1 year. RESULTS On average impedances increased to 13 kOhm before first fitting and dropped to 5-7 kOhm under electrical stimulation with lower values measured on apical contacts. Mean values remained stable over years, but variability increased. Values before first fitting were independent of age at implantation whereas lower values were found later in patients of higher age at implantation. CONCLUSION Despite smaller contacts, impedance values after start of electrical stimulation were comparable to published values of Contour electrodes. This might suggest less tissue growth with the Hybrid-L electrode array.
Collapse
Affiliation(s)
- Simon Konrad
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
| | - Andreas Büchner
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
- Hearing4all Cluster of Excellence, Hannover Medical School, Hannover, Germany
| | - Thomas Lenarz
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
- Hearing4all Cluster of Excellence, Hannover Medical School, Hannover, Germany
| | - Gerrit Paasche
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
- Hearing4all Cluster of Excellence, Hannover Medical School, Hannover, Germany
| |
Collapse
|
4
|
Ding L, Zhang L, Li J, Lin T. Electrode-Modiolus Distance Affects Speech Perception for Lateral Wall Electrodes. Otol Neurotol 2023; 44:e702-e709. [PMID: 37939358 DOI: 10.1097/mao.0000000000004019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2023]
Abstract
OBJECTIVES The goal of this study was to use cone-beam computed tomography to locate the electrode-modiolus distance (EMD) and correlate this with speech perception in cochlear implant (CI) recipients of the 31.5-mm lateral wall (LW) electrode arrays. STUDY DESIGN Retrospective review. PATIENTS Forty-five child CI recipients with prelingual profound sensorineural hearing loss of inserted 31.5-mm LW arrays listening with a CI-alone device. INTERVENTIONS Stepwise forward multiple linear regression was performed to control and reduce the variability in implant performance to determine whether EMD affects speech perception. MAIN OUTCOME MEASURES Electrode location (angular insertion depth [AID], EMD), together with the electrode impedance (EI), surgical approach, sex, CI age, and preimplant hearing aid usage were estimated as independent variables. The dependent variables were the Meaningful Use of Speech Scale (MUSS) and parents' evaluation of children's aural/oral performance (PEACH) assessed with the CI alone at 12 months postactivation. RESULTS EMD and CI age were predictive variables for PEACH/MUSS. A negative correlation was found between AID and EMD (r = -0.56, p < 0.01), whereas EMD had a moderately positive correlation with EI (r = 0.32, p < 0.01). CONCLUSIONS The best "location-related" predictor of postoperative speech perception was EMD with a 31.5-mm array among CI-alone users.
Collapse
Affiliation(s)
- Ling Ding
- Department of Otorhinolaryngology-Head and Neck Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
| | - Luguang Zhang
- Department of Medical Imaging, The Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
| | - Jing Li
- Department of Otorhinolaryngology-Head and Neck Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
| | - Tao Lin
- Department of Neurosurgery, Shandong Second Provincial General Hospital, Jinan, Shandong, 250022, China
| |
Collapse
|
5
|
Dambon J, Munder P, Mewes A, Böhnke B, Beyer A, Kolonko J, Brademann G, Hey M. Optimizing the efficiency of ECAP measurements due to interpolation. Acta Otolaryngol 2023; 143:971-978. [PMID: 38189322 DOI: 10.1080/00016489.2023.2298467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Accepted: 12/11/2023] [Indexed: 01/09/2024]
Abstract
BACKGROUND Thresholds of electrically evoked compound action potentials (TECAP) may serve as starting points for electrophysiologically based fitting of cochlear implants. Absent TECAP data at single electrodes reduces the number of data points available for fitting and can be substituted by interpolation of measured data points. AIM To compare complete TECAP profiles with interpolated TECAP profiles of 5/22 (∼22.7%) and 11/22 (50%) electrode contacts. MATERIAL AND METHODS Single-centre, retrospective, observational study of data from 624 ears implanted with a Slim Modiolar (CI ×32) or Contour Advance (CI ×12, CI24RE(CA)) electrode array (Cochlear Ltd). The deviation of the complete measured TECAP profile from the same profile with missing and therefore interpolated TECAP values was quantified. RESULTS Interpolated TECAP profiles significantly differ from complete measured profiles especially at the basal and apical electrodes. Reference data for Slim Modiolar and Contour Advance electrodes mean profiles are provided. CONCLUSIONS AND SIGNIFICANCE Reducing the number of measured TECAP electrodes has to be weighted against losses in the TECAP accuracy of interpolated values. A clinically acceptable compromise may be a reduction from 22 to 11 even non-equidistant data points. While reducing ECAP measurement time, it is accompanied by a minimal loss of accuracy of the TECAP threshold profile.
Collapse
Affiliation(s)
- Jan Dambon
- Department of Otorhinolaryngology, Head and Neck Surgery, Audiology, University Hospital Schleswig-Holstein (UKSH), Kiel, Germany
| | - Patrick Munder
- itap - Institut für technische und angewandte Physik GmbH, Oldenburg, Germany
| | - Alexander Mewes
- Department of Otorhinolaryngology, Head and Neck Surgery, Audiology, University Hospital Schleswig-Holstein (UKSH), Kiel, Germany
| | - Britta Böhnke
- Department of Otorhinolaryngology, Head and Neck Surgery, Audiology, University Hospital Schleswig-Holstein (UKSH), Kiel, Germany
| | - Annika Beyer
- Department of Otorhinolaryngology, Head and Neck Surgery, Audiology, University Hospital Schleswig-Holstein (UKSH), Kiel, Germany
| | - Johannes Kolonko
- Department of Otorhinolaryngology, Head and Neck Surgery, Audiology, University Hospital Schleswig-Holstein (UKSH), Kiel, Germany
| | - Goetz Brademann
- Department of Otorhinolaryngology, Head and Neck Surgery, Audiology, University Hospital Schleswig-Holstein (UKSH), Kiel, Germany
| | - Matthias Hey
- Department of Otorhinolaryngology, Head and Neck Surgery, Audiology, University Hospital Schleswig-Holstein (UKSH), Kiel, Germany
| |
Collapse
|
6
|
Wei X, Lu S, Chen B, Chen J, Zhang L, Li Y, Kong Y. Cochlear implantation programming characteristics and outcomes of cochlear nerve deficiency. Eur Arch Otorhinolaryngol 2023; 280:4409-4418. [PMID: 37036510 DOI: 10.1007/s00405-023-07949-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 03/29/2023] [Indexed: 04/11/2023]
Abstract
PURPOSE Due to the specificity of cochlear implantation (CI) programming parameters and outcomes in cochlear nerve deficiency (CND) patients, this study aimed to investigate the correlation between programming parameters and outcomes and further compare the difference between normal and CND groups. METHODS Ninety (95 ears) CND patients (normal cochlea, 39; malformed cochlea, 56) and seventy-nine (81 ears) normal cochlea patients who underwent CI surgery with either Med-El or Cochlear devices were included. The programming parameters and outcomes evaluated by the questionnaires were collected and compared among the normal CND, malformed CND, and normal groups in the two device groups, and their correlation was analyzed. RESULTS In the CND group, a reduced stimulation rate, higher pulse width, and triphasic pulse were needed in some cases. The stimulus levels of the CND group were significantly higher than that of the normal group (p < 0.05), but the outcomes of the CND group were significantly worse than that of the normal group (p < 0.05), and the stimulus level was significantly correlated with the outcomes (p < 0.05). However, there was no difference between normal and malformed CND groups. The non-auditory response was observed in the CND group, especially the ones with malformations. CONCLUSION The CI programming parameters of some CND patients need to be adjusted, and a slower stimulation rate and higher pulse width are required sometimes. CND patients need a higher stimulus level than normal patients but their outcomes are poorer. Non-auditory response should be noticed in CND patients during programming.
Collapse
Affiliation(s)
- Xingmei Wei
- Key Laboratory of Otolaryngology Head and Neck Surgery, Department of Otorhinolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Ministry of Education, 1, Dongjiaominxiang, Dongcheng District, Beijing, 100730, People's Republic of China
| | - Simeng Lu
- Key Laboratory of Otolaryngology Head and Neck Surgery, Department of Otorhinolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Ministry of Education, 1, Dongjiaominxiang, Dongcheng District, Beijing, 100730, People's Republic of China
| | - Biao Chen
- Key Laboratory of Otolaryngology Head and Neck Surgery, Department of Otorhinolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Ministry of Education, 1, Dongjiaominxiang, Dongcheng District, Beijing, 100730, People's Republic of China
| | - Jingyuan Chen
- Key Laboratory of Otolaryngology Head and Neck Surgery, Department of Otorhinolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Ministry of Education, 1, Dongjiaominxiang, Dongcheng District, Beijing, 100730, People's Republic of China
| | - Lifang Zhang
- Key Laboratory of Otolaryngology Head and Neck Surgery, Department of Otorhinolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Ministry of Education, 1, Dongjiaominxiang, Dongcheng District, Beijing, 100730, People's Republic of China
| | - Yongxin Li
- Key Laboratory of Otolaryngology Head and Neck Surgery, Department of Otorhinolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Ministry of Education, 1, Dongjiaominxiang, Dongcheng District, Beijing, 100730, People's Republic of China.
| | - Ying Kong
- Key Laboratory of Otolaryngology Head and Neck Surgery, Department of Otorhinolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Ministry of Education, 1, Dongjiaominxiang, Dongcheng District, Beijing, 100730, People's Republic of China.
| |
Collapse
|
7
|
Berg KA, Chen C, Noble JH, Dawant BM, Dwyer RT, Labadie RF, Gifford RH. Effects of the Number of Channels and Channel Stimulation Rate on Speech Recognition and Sound Quality Using Precurved Electrode Arrays. Am J Audiol 2023; 32:403-416. [PMID: 37249492 PMCID: PMC10468116 DOI: 10.1044/2023_aja-22-00032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Revised: 06/16/2022] [Accepted: 02/05/2023] [Indexed: 05/31/2023] Open
Abstract
PURPOSE This study investigated the relationship between the number of active electrodes, channel stimulation rate, and their interaction on speech recognition and sound quality measures while controlling for electrode placement. Cochlear implant (CI) recipients with precurved electrode arrays placed entirely within scala tympani and closer to the modiolus were hypothesized to be able to utilize more channels and possibly higher stimulation rates to achieve better speech recognition performance and sound quality ratings than recipients in previous studies. METHOD Participants included seven postlingually deafened adult CI recipients with Advanced Bionics Mid-Scala electrode arrays confirmed to be entirely within scala tympani using postoperative computerized tomography. Twelve conditions were tested using four, eight, 12, and 16 electrodes and channel stimulation rates of 600 pulse per second (pps), 1,200 pps, and each participant's maximum allowable rate (1,245-4,800 pps). Measures of speech recognition and sound quality were acutely assessed. RESULTS For the effect of channels, results showed no significant improvements beyond eight channels for all measures. For the effect of channel stimulation rate, results showed no significant improvements with higher rates, suggesting that 600 pps was sufficient for maximum speech recognition performance and sound quality ratings. However, across all conditions, there was a significant relationship between mean electrode-to-modiolus distance and all measures, suggesting that a lower mean electrode-to-modiolus distance was correlated with higher speech recognition scores and sound quality ratings. CONCLUSION These findings suggest that even well-placed precurved electrode array recipients may not be able to take advantage of more than eight channels or higher channel stimulation rates (> 600 pps), but that closer electrode array placement to the modiolus correlates with better outcomes for these recipients.
Collapse
Affiliation(s)
- Katelyn A. Berg
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN
| | - Chen Chen
- Research and Technology, Advanced Bionics, LLC, Valencia, CA
| | - Jack H. Noble
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN
| | - Benoit M. Dawant
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN
| | - Robert T. Dwyer
- Research and Technology, Advanced Bionics, LLC, Valencia, CA
| | - Robert F. Labadie
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, Charleston
| | - René H. Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN
| |
Collapse
|
8
|
Lambriks L, van Hoof M, Debruyne J, Janssen M, Hof J, Hellingman K, Devocht E, George E. Toward neural health measurements for cochlear implantation: The relationship among electrode positioning, the electrically evoked action potential, impedances and behavioral stimulation levels. Front Neurol 2023; 14:1093265. [PMID: 36846130 PMCID: PMC9948626 DOI: 10.3389/fneur.2023.1093265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 01/10/2023] [Indexed: 02/11/2023] Open
Abstract
Introduction Estimating differences in neural health across different sites within the individual cochlea potentially enables clinical applications for subjects with a cochlear implant. The electrically evoked compound action potential (ECAP) is a measure of neural excitability that possibly provides an indication of a neural condition. There are many factors, however, that affect this measure and increase the uncertainty of its interpretation. To better characterize the ECAP response, its relationship with electrode positioning, impedances, and behavioral stimulation levels was explored. Methods A total of 14 adult subjects implanted with an Advanced Bionics cochlear electrode array were prospectively followed up from surgery to 6 months postoperative. Insertion depth, distance to the modiolus, and distance to the medial wall were assessed for each electrode by postoperative CT analysis. ECAPs were measured intraoperatively and at three visits postoperatively on all 16 electrodes using the NRI feature of clinical programming software and characterized using multiple parameters. Impedances and behavioral stimulation levels were measured at every fitting session. Results Patterns in ECAPs and impedances were consistent over time, but high variability existed among subjects and between different positions in the cochlea. Electrodes located closer to the apex of the cochlea and closer to the modiolus generally showed higher neural excitation and higher impedances. Maximum loudness comfort levels were correlated strongly with the level of current needed to elicit a response of 100 μV ECAP. Conclusion Multiple factors contribute to the ECAP response in subjects with a cochlear implant. Further research might address whether the ECAP parameters used in this study will benefit clinical electrode fitting or the assessment of auditory neuron integrity.
Collapse
Affiliation(s)
- Lars Lambriks
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands,*Correspondence: Lars Lambriks ✉
| | - Marc van Hoof
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Joke Debruyne
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Miranda Janssen
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands,Department of Methodology and Statistics, Care and Public Health Research Institute, Maastricht University, Maastricht, Netherlands
| | - Janny Hof
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Katja Hellingman
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Elke Devocht
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Erwin George
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| |
Collapse
|
9
|
Singh J, Singh RK, Mishra SK, Jha S. Effect of the vertical facial canal to round window distance concerning neural response telemetry during cochlear implantation in children. Int J Pediatr Otorhinolaryngol 2022; 163:111349. [PMID: 36308882 DOI: 10.1016/j.ijporl.2022.111349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/06/2022] [Revised: 05/29/2022] [Accepted: 10/11/2022] [Indexed: 11/07/2022]
Abstract
OBJECTIVE To assess the correlation of the distance from the round window (RW) to the vertical facial canal (VFC) with neural response telemetry thresholds (T-NRT), which may have an influence on the insertion trajectory and aid in preoperative surgical planning and electrode selection. METHODS An observational study was conducted on 30 prelingually deaf children under five years diagnosed with bilateral severe to profound hearing loss and received a cochlear implant. The preoperative high resolution computed tomography (HRCT) images in the axial cut bone window setting at the round window level was used to calculate the distance from the RW to the VFC on the RadiAnt DICOM Viewer. The intraoperative distance was measured with ScopyDoc version 8.2.4 software. In Auto-NRT mode, software-based recordings (Cochlear's Custom Sound EP 6.0) were used to measure and evaluate the T-NRT current level. RESULTS A statistically significant positive correlation of the RW to VFC distance with the average T-NRT p = 0.02, r = -0.4 and with the mid-frequency, T-NRT p = 0.003, r = -0.5 was found. CONCLUSION The insertion trajectory can be ascertained by a statistically significant correlation between average T-NRT and mid-frequency T-NRT with RW and VFC distance, and this reliable factor can be taken into account in future surgical technique modulation, electrode selection, and electrode design.
Collapse
Affiliation(s)
- Jyoti Singh
- Department of ENT, Indira Gandhi Institute of Medical Sciences, Patna, India
| | - Rakesh Kumar Singh
- Department of ENT, Indira Gandhi Institute of Medical Sciences, Patna, India.
| | | | - Shruti Jha
- Department of ENT, Indira Gandhi Institute of Medical Sciences, Patna, India
| |
Collapse
|
10
|
Bratu EL, Sunderhaus LW, Berg KA, Dwyer RT, Labadie RF, Gifford RH, Noble JH. Activation region overlap visualization for image-guided cochlear implant programming. Biomed Phys Eng Express 2022; 9:10.1088/2057-1976/ac9aba. [PMID: 36594887 PMCID: PMC10072294 DOI: 10.1088/2057-1976/ac9aba] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Accepted: 10/17/2022] [Indexed: 11/24/2022]
Abstract
Objective. The cochlear implant is a neural prosthesis designed to directly stimulate auditory nerve fibers to induce the sensation of hearing in those experiencing severe-to-profound hearing loss. After surgical implantation, audiologists program the implant's external processor with settings intended to produce optimal hearing outcomes. The likelihood of achieving optimal outcomes increases when audiologists have access to tools that objectively present information related to the patient's own anatomy and surgical outcomes. This includes visualizations like the one presented here, termed the activation region overlap image, which is designed to decrease subjectivity when determining amounts of overlapping stimulation between implant electrodes.Approach. This visualization uses estimates of electric field strength to indicate spread of neural excitation due to each electrode. Unlike prior visualizations, this method explicitly defines regions of nerves receiving substantial stimulation from each electrode to help clinicians assess the presence of significant overlapping stimulation. A multi-reviewer study compared this and an existing technique on the consistency, efficiency, and optimality of plans generated from each method. Statistical significance was evaluated using the two-sided Wilcoxon rank sum test.Main results. The study showed statistically significant improvements in consistency (p < 10-12), efficiency (p < 10-15), and optimality (p < 10-5) when generating plans using the proposed method versus the existing method.Significance. This visualization addresses subjectivity in assessing overlapping stimulation between implant electrodes, which currently relies on reviewer estimates. The results of the evaluation indicate the provision of such objective information during programming sessions would likely benefit clinicians in making programming decisions.
Collapse
Affiliation(s)
- Erin L. Bratu
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, TN, USA
| | - Linsey W. Sunderhaus
- Vanderbilt University Medical Center, Department of Hearing and Speech Sciences, Nashville, TN, USA
| | - Katelyn A. Berg
- Vanderbilt University Medical Center, Department of Hearing and Speech Sciences, Nashville, TN, USA
| | - Robert T. Dwyer
- Vanderbilt University Medical Center, Department of Hearing and Speech Sciences, Nashville, TN, USA
| | - Robert F. Labadie
- Vanderbilt University Medical Center, Department of Hearing and Speech Sciences, Nashville, TN, USA
| | - René H. Gifford
- Vanderbilt University Medical Center, Department of Hearing and Speech Sciences, Nashville, TN, USA
| | - Jack H. Noble
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, TN, USA
- Vanderbilt University Medical Center, Department of Hearing and Speech Sciences, Nashville, TN, USA
- Vanderbilt University Medical Center, Department of Otolaryngology – Head & Neck Surgery, Nashville, TN, USA
| |
Collapse
|
11
|
Munhall CC, Noble JH, Dawant B, Labadie RF. Cochlear Implant Translocation: Diagnosis, Prevention, and Clinical Implications. CURRENT OTORHINOLARYNGOLOGY REPORTS 2022. [DOI: 10.1007/s40136-022-00434-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
12
|
Hoffmann JAC, Warnecke A, Timm ME, Kludt E, Prenzler NK, Gärtner L, Lenarz T, Salcher RB. Cochlear Implantation in Obliterated Cochlea: A Retrospective Analysis and Comparison between the IES Stiff Custom-Made Device and the Split-Array and Regular Electrodes. J Clin Med 2022; 11:jcm11206090. [PMID: 36294411 PMCID: PMC9605638 DOI: 10.3390/jcm11206090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 10/12/2022] [Accepted: 10/13/2022] [Indexed: 11/07/2022] Open
Abstract
Anatomical malformations, obliterations of the cochlea, or re-implantations pose particular challenges in cochlear implantation. Treatment methods rely on radiological and intraoperative findings and include incomplete insertion, the implantation of a double array, and radical cochleostomy. In addition, a stiff electrode array, e.g., the IE stiff (IES) custom-made device (CMD, MED-EL), was prescribed individually for those special cases and pre-inserted prior to facilitate cochlear implantation in challenging cases. Data on outcomes after implantation in obliterated cochleae are usually based on individual case reports since standardised procedures are lacking. A retrospective analysis was conducted to analyse our cases on obliterated cochleae treated with MED-EL devices in order to allow the different cases to be compared. Impedances and speech perception data of patients treated with the IES CMD and the double array were retrospectively compared to patients treated with a STANDARD or FLEX electrode array (the REGULAR group). Patients with a Split-Array CMD had a poor speech perception when compared to patients treated with the IES CMD device. Thus, the IES CMD can successfully be used in patients with obliterated cochleae who would otherwise be non-users, candidates for a Split-Array CMD, or candidates for partial insertion with insufficient cochlear coverage.
Collapse
Affiliation(s)
| | - Athanasia Warnecke
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medial School, 30625 Hannover, Germany
- Cluster of Excellence “Hearing4all”, Hannover Medical School, 30625 Hannover, Germany
| | - Max Eike Timm
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medial School, 30625 Hannover, Germany
- Cluster of Excellence “Hearing4all”, Hannover Medical School, 30625 Hannover, Germany
| | - Eugen Kludt
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medial School, 30625 Hannover, Germany
- Cluster of Excellence “Hearing4all”, Hannover Medical School, 30625 Hannover, Germany
| | - Nils Kristian Prenzler
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medial School, 30625 Hannover, Germany
- Cluster of Excellence “Hearing4all”, Hannover Medical School, 30625 Hannover, Germany
| | - Lutz Gärtner
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medial School, 30625 Hannover, Germany
- Cluster of Excellence “Hearing4all”, Hannover Medical School, 30625 Hannover, Germany
| | - Thomas Lenarz
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medial School, 30625 Hannover, Germany
- Cluster of Excellence “Hearing4all”, Hannover Medical School, 30625 Hannover, Germany
| | - Rolf Benedikt Salcher
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medial School, 30625 Hannover, Germany
- Cluster of Excellence “Hearing4all”, Hannover Medical School, 30625 Hannover, Germany
- Correspondence:
| |
Collapse
|
13
|
Assessing the Placement of the Cochlear Slim Perimodiolar Electrode Array by Trans Impedance Matrix Analysis: A Temporal Bone Study. J Clin Med 2022; 11:jcm11143930. [PMID: 35887693 PMCID: PMC9317462 DOI: 10.3390/jcm11143930] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 06/28/2022] [Accepted: 07/01/2022] [Indexed: 01/25/2023] Open
Abstract
New cochlear implant (CI) electrode arrays provide softer insertion dynamics; however, due to their high flexibility, the possibilities of fold-overs or intraoperative displacements must be taken into account. The position of each individual electrode can only be determined by using high-resolution computed tomography or cone-beam CT. The trans-impedance matrix test (TIM) is an electrophysiological method based on electric field imaging that can provide images of electrode position and electrode folding. Objective: In this experimental research, we evaluated the result of TIM as a method of monitoring cochlear insertion for a precurved slim modiolar electrode array in fresh human temporal bones by analyzing the transimpedance matrix patterns and their correlation with electrode position using high-resolution computed tomography. Material and Methods: Sixteen slim modiolar electrode arrays were inserted into eight fresh Human Temporal Bones. Eight electrodes were inserted according to the correct methodology of insertion, and eight were intentionally folded over. After all insertions, a trans-impedance matrix analysis and a Cone Beam CT (CBCT) were performed in each temporal bone. Results: If we correlated the TIM patterns with the radiological electrode position, we observed that better electrode intracochlear positions indicated more “homogeneous” TIM patterns (intracochlear voltage dropped monotonically as the distance between stimulation and recording contact increased, both toward the apex and toward the base). A correlation where fold-over was detected in the TIM results was found in all eight temporal bone radiological findings. Conclusions: Trans-Impedance Matrix patterns were correlated with the radiological CI electrode position. When a tip fold-over appeared, a matrix with a secondary ridge in addition to the primary ridge was observed in all cases. TIM can be an effective method in the control of electrode positioning.
Collapse
|
14
|
Berg KA, Noble JH, Dawant BM, Dwyer RT, Labadie RF, Gifford RH. Speech recognition as a function of the number of channels for Mid-Scala electrode array recipients. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 152:67. [PMID: 35931512 PMCID: PMC9984239 DOI: 10.1121/10.0012163] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
This study investigated the number of channels needed for maximum speech understanding and sound quality in 15 adult cochlear implant (CI) recipients with Advanced Bionics (AB) Mid-Scala electrode arrays completely within scala tympani. In experiment I, CI programs used a continuous interleaved sampling (CIS)-based strategy and 4-16 active electrodes. In experiment II, CI programs used an n-of-m strategy featuring 16 active electrodes with either 8- or 12-maxima. Speech understanding and sound quality measures were assessed. For CIS programs, participants demonstrated performance gains using up to 4-10 electrodes on speech measures and sound quality ratings. For n-of-m programs, there was no significant effect of maxima, suggesting 8-maxima is sufficient for this sample's maximum performance and sound quality. These results are largely consistent with previous studies using straight electrode arrays [e.g., Fishman, Shannon, and Slattery (1997). J. Speech Lang. Hear. Res. 40, 1201-1215; Friesen, Shannon, Baskent, and Wang (2001). J. Acoust. Soc. Am. 110, 1150-1163; Shannon, Cruz, and Galvin (2011). Audiol. Neurotol. 16, 113-123; Berg, Noble, Dawant, Dwyer, Labadie, and Gifford (2020). J. Acoust. Soc. Am. 147, 3646-3656] and in contrast with recent studies looking at cochlear precurved electrode arrays [e.g., Croghan, Duran, and Smith (2017). J. Acoust. Soc. Am. 142, EL537-EL543; Berg, Noble, Dawant, Dwuer, Labadie, and Gifford (2019b). J. Acoust. Soc. Am. 145, 1556-1564], which found continuous improvements up to 16 independent channels. These findings suggest that Mid-Scala electrode array recipients demonstrate similar channel independence to straight electrode arrays rather than other manufacturer's precurved electrode arrays.
Collapse
Affiliation(s)
- Katelyn A Berg
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - Jack H Noble
- Department of Electrical Engineering and Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA
| | - Benoit M Dawant
- Department of Electrical Engineering and Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA
| | - Robert T Dwyer
- Advanced Bionics, 28515 Westinghouse Place, Valencia, California 91355, USA
| | - Robert F Labadie
- Department of Otolaryngology, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - René H Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| |
Collapse
|
15
|
Mewes A, Burg S, Brademann G, Dambon JA, Hey M. Quality-assured training in the evaluation of cochlear implant electrode position: a prospective experimental study. BMC MEDICAL EDUCATION 2022; 22:386. [PMID: 35596162 PMCID: PMC9121556 DOI: 10.1186/s12909-022-03464-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Accepted: 05/13/2022] [Indexed: 06/15/2023]
Abstract
BACKGROUND The objective of this study was to demonstrate the utility of an approach in training predoctoral medical students, to enable them to measure electrode-to-modiolus distances (EMDs) and insertion-depth angles (aDOIs) in cochlear implant (CI) imaging at the performance level of a single senior rater. METHODS This prospective experimental study was conducted on a clinical training dataset comprising patients undergoing cochlear implantation with a Nucleus® CI532 Slim Modiolar electrode (N = 20) or a CI512 Contour Advance electrode (N = 10). To assess the learning curves of a single medical student in measuring EMD and aDOI, interrater differences (senior-student) were compared with the intrarater differences of a single senior rater (test-retest). The interrater and intrarater range were both calculated as the distance between the 0.1th and 99.9th percentiles. A "deliberate practice" training approach was used to teach knowledge and skills, while correctives were applied to minimize faulty data-gathering and data synthesis. RESULTS Intrarater differences of the senior rater ranged from - 0.5 to 0.5 mm for EMD and - 14° to 16° for aDOI (respective medians: 0 mm and 0°). Use of the training approach led to interrater differences that matched this after the 4th (EMD) and 3rd (aDOI) feedback/measurement series had been provided to the student. CONCLUSIONS The training approach enabled the student to evaluate the CI electrode position at the performance level of a senior rater. This finding may offer a basis for ongoing clinical quality assurance for the assessment of CI electrode position.
Collapse
Affiliation(s)
- Alexander Mewes
- Universitätsklinikum Schleswig-Holstein (UKSH), Campus Kiel, Department of Otorhinolaryngology, Head and Neck Surgery, Kiel, Germany.
| | - Sebastian Burg
- Christian-Albrechts-Universität (CAU) zu Kiel, Faculty of Medicine, Kiel, Germany
| | - Goetz Brademann
- Universitätsklinikum Schleswig-Holstein (UKSH), Campus Kiel, Department of Otorhinolaryngology, Head and Neck Surgery, Kiel, Germany
| | - Jan Andreas Dambon
- Universitätsklinikum Schleswig-Holstein (UKSH), Campus Kiel, Department of Otorhinolaryngology, Head and Neck Surgery, Kiel, Germany
| | - Matthias Hey
- Universitätsklinikum Schleswig-Holstein (UKSH), Campus Kiel, Department of Otorhinolaryngology, Head and Neck Surgery, Kiel, Germany
| |
Collapse
|
16
|
Sijgers L, Huber A, Tabibi S, Grosse J, Roosli C, Boyle P, Koka K, Dillier N, Pfiffner F, Dalbert A. Predicting Cochlear Implant Electrode Placement Using Monopolar, Three-Point and Four-Point Impedance Measurements. IEEE Trans Biomed Eng 2022; 69:2533-2544. [PMID: 35143392 DOI: 10.1109/tbme.2022.3150239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE This study aimed to investigate the relationship between cochlear implant (CI) electrode distances to the cochleas inner wall (the modiolus) and electrical impedance measurements made at the CIs electrode contacts. We introduced a protocol for three-point impedances in which we recorded bipolar impedances in response to monopolar stimulation at a neighboring electrode. We aimed to assess the usability of three-point impedances and two existing CI impedance measurement methods (monopolar and four-point impedances) for predicting electrode positioning during CI insertion. METHODS Impedances were recorded during stepwise CI electrode array insertions in cadaveric human temporal bones. The positioning of the electrodes with respect to the modiolus was assessed at each step using cone beam computed tomography. Linear mixed regression analysis was performed to assess the relationship between the impedances and electrode-modiolar distances. The experimental results were compared to clinical impedance data and to an existing lumped-element model of an implanted CI. RESULTS Three-point and four-point impedances strongly correlated with electrode-modiolar distance. In contrast, monopolar impedances were only minimally affected by changes in electrode positioning with respect to the modiolus. An overall model specificity of 62% was achieved when incorporating all impedance parameters. This specificity could be increased beyond 73% when prior expectations of electrode positioning were incorporated in the model. CONCLUSION Three-point and four-point impedances are promising measures to predict electrode-modiolar distance in real-time during CI insertion. SIGNIFICANCE This work shows how electrical impedance measurements can be used to predict the CIs electrode positioning in a biologically realistic model.
Collapse
|
17
|
Heshmat A, Sajedi S, Schrott-Fischer A, Rattay F. Polarity Sensitivity of Human Auditory Nerve Fibers Based on Pulse Shape, Cochlear Implant Stimulation Strategy and Array. Front Neurosci 2021; 15:751599. [PMID: 34955717 PMCID: PMC8692583 DOI: 10.3389/fnins.2021.751599] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Accepted: 11/08/2021] [Indexed: 11/28/2022] Open
Abstract
Neural health is of great interest to determine individual degeneration patterns for improving speech perception in cochlear implant (CI) users. Therefore, in recent years, several studies tried to identify and quantify neural survival in CI users. Among all proposed techniques, polarity sensitivity is a promising way to evaluate the neural status of auditory nerve fibers (ANFs) in CI users. Nevertheless, investigating neural health based on polarity sensitivity is a challenging and complicated task that involves various parameters, and the outcomes of many studies show contradictory results of polarity sensitivity behavior. Our computational study benefits from an accurate three-dimensional finite element model of a human cochlea with realistic human ANFs and determined ANF degeneration pattern of peripheral part with a diminishing of axon diameter and myelination thickness based on degeneration levels. In order to see how different parameters may impact the polarity sensitivity behavior of ANFs, we investigated polarity behavior under the application of symmetric and asymmetric pulse shapes, monopolar and multipolar CI stimulation strategies, and a perimodiolar and lateral CI array system. Our main findings are as follows: (1) action potential (AP) initiation sites occurred mainly in the peripheral site in the lateral system regardless of stimulation strategies, pulse polarities, pulse shapes, cochlear turns, and ANF degeneration levels. However, in the perimodiolar system, AP initiation sites varied between peripheral and central processes, depending on stimulation strategies, pulse shapes, and pulse polarities. (2) In perimodiolar array, clusters formed in threshold values based on cochlear turns and degeneration levels for multipolar strategies only when asymmetric pulses were applied. (3) In the perimodiolar array, a declining trend in polarity (anodic threshold/cathodic threshold) with multipolar strategies was observed between intact or slight degenerated cases and more severe degenerated cases, whereas in the lateral array, cathodic sensitivity was noticed for intact and less degenerated cases and anodic sensitivity for cases with high degrees of degeneration. Our results suggest that a combination of asymmetric pulse shapes, focusing more on multipolar stimulation strategies, as well as considering the distances to the modiolus wall, allows us to distinguish the degeneration patterns of ANFs across the cochlea.
Collapse
Affiliation(s)
- Amirreza Heshmat
- Institute for Analysis and Scientific Computing, Vienna University of Technology, Vienna, Austria.,Laboratory for Inner Ear Biology, Department of Otorhinolaryngology, Medical University of Innsbruck, Innsbruck, Austria
| | - Sogand Sajedi
- Institute for Analysis and Scientific Computing, Vienna University of Technology, Vienna, Austria
| | - Anneliese Schrott-Fischer
- Laboratory for Inner Ear Biology, Department of Otorhinolaryngology, Medical University of Innsbruck, Innsbruck, Austria
| | - Frank Rattay
- Institute for Analysis and Scientific Computing, Vienna University of Technology, Vienna, Austria
| |
Collapse
|
18
|
Sunwoo W, Jeon HW, Choi BY. Effect of initial switch-on within 24 hours of cochlear implantation using slim modiolar electrodes. Sci Rep 2021; 11:22809. [PMID: 34815432 PMCID: PMC8611070 DOI: 10.1038/s41598-021-01862-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Accepted: 11/01/2021] [Indexed: 11/09/2022] Open
Abstract
Reducing electrode impedance is an important factor in improving the functional benefits of cochlear implants (CIs). The immediate effect of early switch-on within 24 h of surgery on impedance among CI recipients with various types of electrodes has been reported previously; however, the immediate change and the evolution of electrode impedances of slim modiolar electrodes after early switch-on within 24 h of implantation has not. Therefore, the focus of this retrospective cohort study of CI patients was to compare the effect of early switch-on (n = 36) and conventional switch-on (n = 72) 2–4 weeks post-operation on impedance. Compared with impedance measured intraoperatively, our results demonstrate a significant decrease in impedance from 11.5 to 8.9 kΩ (p < 0.001) at 2–4 weeks after implantation in the early switch-on group, which sharply contrasted with elevated impedance values for conventional switch-on 2–4 weeks after implantation (from 10.7 to 14.2 kΩ, p = 0.001). Notably, a comparatively lower impedance than the conventional switch-on protocol was observed for up to 2 months post-operation. Most importantly, a much earlier stabilization of impedance can be achieved with the early switch-on protocol coupled with the slim modiolar electrode array compared to the conventional switch-on protocol, offering the advantage of reducing the number of required mapping sessions in the early stages of rehabilitation.
Collapse
Affiliation(s)
- Woongsang Sunwoo
- Department of Otorhinolaryngology-Head and Neck Surgery, Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea
| | - Hyoung Won Jeon
- Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, 300 Gumi-dong, Bundang-gu, Seongnam, 13620, Republic of Korea
| | - Byung Yoon Choi
- Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, 300 Gumi-dong, Bundang-gu, Seongnam, 13620, Republic of Korea.
| |
Collapse
|
19
|
Dong Y, Briaire JJ, Siebrecht M, Stronks HC, Frijns JHM. Detection of Translocation of Cochlear Implant Electrode Arrays by Intracochlear Impedance Measurements. Ear Hear 2021; 42:1397-1404. [PMID: 33974777 PMCID: PMC8378542 DOI: 10.1097/aud.0000000000001033] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Misplacement of the electrode array is associated with impaired speech perception in patients with cochlear implants (CIs). Translocation of the electrode array is the most common misplacement. When a CI is translocated, it crosses the basilar membrane from the scala tympani into the scala vestibuli. The position of the implant can be determined on a postoperative CT scan. However, such a scan is not obtained routinely after CI insertion in many hospitals, due to radiation exposure and processing time. Previous studies have shown that impedance measures might provide information on the placement of the electrode arrays. The electrode impedance was measured by dividing the plateau voltage at the end of the first phase of the pulse by the injected current. The access resistance was calculated using the so-called access voltage at the first sampled time point after the start of the pulse divided by the injected current. In our study, we obtained the electrode impedance and the access resistance to detect electrode translocations using electrical field imaging. We have investigated how reliably these two measurements can detect electrode translocation, and which method performed best. DESIGN We calculated the electrode impedances and access resistances using electrical field imaging recordings from 100 HiFocus Mid-Scala CI (Advanced Bionics, Sylmar, CA) recipients. We estimated the normal values of these two measurements as the baselines of the implant placed in the cochlea without translocation. Next, we calculated the maximal electrode impedance deviation and the maximal access-resistance deviation from the respective baselines as predictors of translocation. We classified these two predictors as translocations or nontranslocations based on the bootstrap sampling method and receiver operating characteristics curves analysis. The accuracy could be calculated by comparing those predictive results to a gold standard, namely the clinical CT scans. To determine which measurement more accurately detected translocation, the difference between the accuracies of the two measurements was calculated. RESULTS Using the bootstrap sampling method and receiver operating characteristics-based optimized threshold criteria, the 95% confidence intervals of the accuracies of translocation detections ranged from 77.8% to 82.1% and from 89.5% to 91.2% for the electrode impedance and access resistance, respectively. The accuracies of the maximal access-resistance deviations were significantly larger than that of the maximal electrode impedance deviations. The location of the translocation as predicted by the access resistance was significantly correlated with the result derived from the CT scans. In contrast, no significant correlation was observed for the electrode impedance. CONCLUSIONS Both the electrode impedance and access resistance proved reliable metrics to detect translocations for HiFocus Mid-Scala electrode arrays. The access resistance had, however, significantly better accuracy and it also reliably detected the electrode-location of translocations. The electrode impedance did not correlate significantly with the location of translocation. Measuring the access resistance is, therefore, the recommended method to detect electrode-array translocations. These measures can provide prompt feedback for surgeons after insertion, improving their surgical skills, and ultimately reducing the number of translocations. In the future, such measurements may allow near-real-time monitoring of the electrode array during insertion, helping to avoid translocations.
Collapse
Affiliation(s)
- Yu Dong
- ENT-Department, Leiden University Medical Centre, RC Leiden, the Netherlands
| | - Jeroen J. Briaire
- ENT-Department, Leiden University Medical Centre, RC Leiden, the Netherlands
| | - Michael Siebrecht
- ENT-Department, Leiden University Medical Centre, RC Leiden, the Netherlands
| | | | - Johan H. M. Frijns
- ENT-Department, Leiden University Medical Centre, RC Leiden, the Netherlands
- Leiden Institute for Brain and Cognition, RC Leiden, the Netherlands
| |
Collapse
|
20
|
Ramos-de-Miguel A, Falcón-González JC, Ramos-Macias A. Analysis of Neural Interface When Using Modiolar Electrode Stimulation. Radiological Evaluation, Trans-Impedance Matrix Analysis and Effect on Listening Effort in Cochlear Implantation. J Clin Med 2021; 10:jcm10173962. [PMID: 34501410 PMCID: PMC8432261 DOI: 10.3390/jcm10173962] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2021] [Revised: 08/11/2021] [Accepted: 08/31/2021] [Indexed: 11/24/2022] Open
Abstract
Background: The proximity of the electrode to the modiolar wall may be of interest to investigate the effect of pitch discrimination. This research establishes the relation between these factors and whether perimodiolar positions may provide benefits regarding improved electrode discrimination. Methods: A prospective randomized study including 24 post-lingual deaf adults was performed. A psychoacoustic study was done by using a psychoacoustic research platform. Radiological study, and a cone-beam computed tomography was used to assess post cochlear implantation electrodes’ position. Trans-impedance matrix (TIM) analysis was performed after cochlear implant insertion in all cases, and pupillometry test was also performed. Results: 12 patients received a slim perimodiolar electrode array, and 12 patients received a straight electrode array. Although all the patients showed similar speech test results after 12 months follow-up, those implanted with a perimodiolar electrode obtained better scores in electrode discrimination test and pupillometry test, and showed more homogenous TIM patterns. Conclusions: The better positioning of the electrode array seams to provide a better hearing resolution and less listening effort trans-impedance matrix seems to be a useful tool to analyze positioning of the perimodiolar array.
Collapse
Affiliation(s)
- Angel Ramos-de-Miguel
- Hearing and Balance Laboratory, Las Palmas de Gran Canaria University (SIANI), 35001 Las Palmas, Spain;
- Correspondence:
| | - Juan Carlos Falcón-González
- Department of Otolaryngology, Head and Neck Surgery, Complejo Hospitalario Universitario Insular Materno Infantil de Gran Canaria, 35016 Las Palmas, Spain;
| | - Angel Ramos-Macias
- Hearing and Balance Laboratory, Las Palmas de Gran Canaria University (SIANI), 35001 Las Palmas, Spain;
- Department of Otolaryngology, Head and Neck Surgery, Complejo Hospitalario Universitario Insular Materno Infantil de Gran Canaria, 35016 Las Palmas, Spain;
| |
Collapse
|
21
|
Relationship Between Speech Recognition in Quiet and Noise and Fitting Parameters, Impedances and ECAP Thresholds in Adult Cochlear Implant Users. Ear Hear 2021; 41:935-947. [PMID: 31702597 DOI: 10.1097/aud.0000000000000814] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The objective of this study was to identify parameters which are related to speech recognition in quiet and in noise of cochlear implant (CI) users. These parameters may be important to improve current fitting practices. DESIGN Adult CI users who visited the Amsterdam UMC, location VUmc, for their annual follow-up between January 2015 and December 2017 were retrospectively identified. After applying inclusion criteria, the final study population consisted of 138 postlingually deaf adult Cochlear CI users. Prediction models were built with speech recognition in quiet and in noise as the outcome measures, and aided sound field thresholds, and parameters related to fitting (i.e., T and C levels, dynamic range [DR]), evoked compound action potential thresholds and impedances as the independent variables. A total of 33 parameters were considered. Separate analyses were performed for postlingually deafened CI users with late onset (LO) and CI users with early onset (EO) of severe hearing impairment. RESULTS Speech recognition in quiet was not significantly different between the LO and EO groups. Speech recognition in noise was better for the LO group compared with the EO group. For CI users in the LO group, mean aided thresholds, mean electrical DR, and measures to express the impedance profile across the electrode array were identified as predictors of speech recognition in quiet and in noise. For CI users in the EO group, the mean T level appeared to be a significant predictor in the models for speech recognition in quiet and in noise, such that CI users with elevated T levels had worse speech recognition in quiet and in noise. CONCLUSIONS Significant parameters related to speech recognition in quiet and in noise were identified: aided thresholds, electrical DR, T levels, and impedance profiles. The results of this study are consistent with previous study findings and may guide audiologists in their fitting practices to improve the performance of CI users. The best performance was found for CI users with aided thresholds around the target level of 25 dB HL, and an electrical DR between 40 and 60 CL. However, adjustments of T and/or C levels to obtain aided thresholds around the target level and the preferred DR may not always be acceptable for individual CI users. Finally, clinicians should pay attention to profiles of impedances other than a flat profile with mild variations.
Collapse
|
22
|
Risk Factors for Facial Nerve and Other Nonauditory Side Effects Following Cochlear Implantation. Otol Neurotol 2021; 42:e1022-e1029. [PMID: 34398109 DOI: 10.1097/mao.0000000000003162] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The purpose of this study was to characterize a cohort of patients with nonauditory side-effects (NASx) following cochlear implant (CI) surgery. STUDY DESIGN Retrospective case review. SETTING Tertiary referral center. PATIENTS One hundred twenty three multichannel CI recipients with intraoperative facial nerve stimulation (FNS). INTERVENTIONS Intraoperative electrical auditory brainstem responses (eABR) during CI surgery. MAIN OUTCOME MEASURES Nonauditory side effects post-CI activation. RESULTS Intraoperative FNS was identified in 2.26% of patients (123/5441), of whom, 34% (42/123) experienced VII stimulation on CI activation. Pain was experienced by 22% (27/123) and vestibular dysfunction was experienced by 4% (5/123) of cases. All case who experienced pain and/or vestibular NASx also experienced VII stimulation. The majority of cases were managed by CI remapping or observation and habituation.Significant relationships were found between etiology of hearing loss and presence of FNS upon initial activation (p < 0.05). No significance was found between FNS intraoperatively and at initial activation for all assumed mechanisms of hearing loss (p > 0.05) with the exceptions of acquired hearing loss of undetermined etiology and toxic etiology group (p < 0.05).There was no significant impact of implant array design (p > 0.05). CONCLUSIONS This study has characterized patients with NASx in a large cohort of CI patients. One third of cases identified with FNS intraoperatively, developed NASx post-CI activation. Risk factors for NASx postactivation include high-risk etiologies and intraoperative objective measures (i.e., eABR). This may assist surgeons and audiologists to identify at-risk patients who may need modifications in CI program planning.
Collapse
|
23
|
Schurzig D, Fröhlich M, Raggl S, Scheper V, Lenarz T, Rau TS. Uncoiling the Human Cochlea-Physical Scala Tympani Models to Study Pharmacokinetics Inside the Inner Ear. Life (Basel) 2021; 11:life11050373. [PMID: 33919445 PMCID: PMC8143569 DOI: 10.3390/life11050373] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 04/15/2021] [Accepted: 04/20/2021] [Indexed: 11/16/2022] Open
Abstract
In the field of cochlear implantation, artificial/physical models of the inner ear are often employed to investigate certain phenomena like the forces occurring during implant insertions. Up to now, no such models are available for the analysis of diffusion processes inside the cochlea although drug delivery is playing an increasingly important role in this field. For easy access of the cochlea along its whole profile, e.g., for sequential sampling in an experimental setting, such a model should ideally be longitudinal/uncoiled. Within this study, a set of 15 micro-CT imaging datasets of human cochleae was used to derive an average representation of the scala tympani. The spiral profile of this model was then uncoiled along different trajectories, showing that these trajectories influence both length and volume of the resulting longitudinal model. A volumetric analysis of the average spiral model was conducted to derive volume-to-length interrelations for the different trajectories, which were then used to generate two tubular, longitudinal scala tympani models with volume and length properties matching the original, spiral profile. These models can be downloaded for free and used for reproducible and comparable simulative and experimental investigations of diffusion processes within the inner ear.
Collapse
Affiliation(s)
- Daniel Schurzig
- MED-EL Research Center, 30625 Hannover, Germany;
- Department of Otolaryngology, Hannover Medical School, 30625 Hannover, Germany; (V.S.); (T.L.); (T.S.R.)
- Correspondence: ; Tel.: +49-511-1659-4795
| | - Max Fröhlich
- MED-EL Research Center, 30625 Hannover, Germany;
- Department of Otolaryngology, Hannover Medical School, 30625 Hannover, Germany; (V.S.); (T.L.); (T.S.R.)
| | - Stefan Raggl
- MED-EL Medical Electronics, 6020 Innsbruck, Austria;
| | - Verena Scheper
- Department of Otolaryngology, Hannover Medical School, 30625 Hannover, Germany; (V.S.); (T.L.); (T.S.R.)
| | - Thomas Lenarz
- Department of Otolaryngology, Hannover Medical School, 30625 Hannover, Germany; (V.S.); (T.L.); (T.S.R.)
| | - Thomas S. Rau
- Department of Otolaryngology, Hannover Medical School, 30625 Hannover, Germany; (V.S.); (T.L.); (T.S.R.)
| |
Collapse
|
24
|
Audiologic Outcomes of Cochlear Implantation in Cochlear Malformations: A Comparative Analysis of Lateral Wall and Perimodiolar Electrode Arrays. Otol Neurotol 2021; 41:e1201-e1206. [PMID: 33433084 DOI: 10.1097/mao.0000000000002833] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Cochlear implantation in children with inner ear malformations has been shown to be beneficial. The aims of this study are to evaluate open set word recognition outcomes among children with cochlear implants who have cochlear malformations, and to further assess if either the lateral wall (LW) or perimodiolar (PM) electrode arrays confer any performance outcome advantages. STUDY DESIGN Retrospective case series. SETTING Tertiary referral center. PATIENTS Pediatric cochlear implant recipients with cochlear malformations who were implanted at our institution within the last 10 years and had speech perception scores were eligible for inclusion in the study. Potential participants were excluded if they had less than 1 year of listening experience with the cochlear implant or suspected cochlear nerve deficiency. INTERVENTION None. MAIN OUTCOME MEASURE Most recent consonant-nucleus-consonant word score. RESULTS ANOVA analysis demonstrated that the type of cochlear malformation was significantly associated with speech perception outcome (p = 0.006). Those with IP2 malformations had significantly better word recognition outcomes than the remaining cochlear malformations. Array type (LW or PM) was not associated with better word recognition outcomes in long-term follow-up of patients with IP2 malformations (p = 0.13). CONCLUSIONS In children who have cochlear malformations, cochlear implantation results in varying word recognition outcomes based on the type of malformation. While the participants in this study demonstrated postoperative open set word recognition skills, those with IP2 malformations demonstrated the most benefit. Electrode type was not found to significantly impact outcomes in this cohort.
Collapse
|
25
|
Abstract
OBJECTIVE The intracochlear position of an electrode array may influence the outcome after cochlear implantation. The design of the electrode array can increase the risk of trauma causing penetration of the basilar membrane or shift of the electrode array into the scala vestibuli. The aim of the present study was to identify a scalar shift after implantation of two different electrode arrays developed by one manufacturer. STUDY DESIGN Retrospective analysis. SETTING Tertiary referral center. PATIENTS AND INTERVENTION Cochlear implant recipients implanted between 2010 and 2014 and receiving either a mid-scala (n = 30) or a perimodiolar (n = 30) electrode array. MAIN OUTCOME MEASURE Occurrence of scalar shift in association with the electrode type. RESULTS Scalar shift occurred in 26.7% (8 of 30) of the patients implanted with a perimodiolar electrode array and in 6.7% (2 of 30) of the patients implanted with the mid-scala electrode array. The mean insertion depth in the patients experiencing scalar shift after implantation of the mid-scala electrode was much deeper (21.59 ± 0.34 mm) when compared with the mean insertion depth of the patients with scalar shift after implantation with a perimodiolar electrode array (17.85 ± 2.19 mm). There tends to be a correlation between the cochlear length and the occurrence of a scalar shift. However, the number of patients with scalar shift in the mid-scala group is rather small. CONCLUSION Based on the presented data, more patients implanted with a perimodiolar electrode array have a scalar shift when compared with the midscalar electrode array.
Collapse
|
26
|
Berg KA, Noble JH, Dawant BM, Dwyer RT, Labadie RF, Gifford RH. Speech recognition as a function of the number of channels for an array with large inter-electrode distances. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:2752. [PMID: 33940865 PMCID: PMC8062138 DOI: 10.1121/10.0004244] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 03/22/2021] [Accepted: 03/22/2021] [Indexed: 05/28/2023]
Abstract
This study investigated the number of channels available to cochlear implant (CI) recipients for maximum speech understanding and sound quality for lateral wall electrode arrays-which result in large electrode-to-modiolus distances-featuring the greatest inter-electrode distances (2.1-2.4 mm), the longest active lengths (23.1-26.4 mm), and the fewest number of electrodes commercially available. Participants included ten post-lingually deafened adult CI recipients with MED-EL electrode arrays (FLEX28 and STANDARD) entirely within scala tympani. Electrode placement and scalar location were determined using computerized tomography. The number of channels was varied from 4 to 12 with equal spatial distribution across the array. A continuous interleaved sampling-based strategy was used. Speech recognition, sound quality ratings, and a closed-set vowel recognition task were measured acutely for each electrode condition. Participants did not demonstrate statistically significant differences beyond eight channels at the group level for almost all measures. However, several listeners showed considerable improvements from 8 to 12 channels for speech and sound quality measures. These results suggest that channel interaction caused by the greater electrode-to-modiolus distances of straight electrode arrays could be partially compensated for by a large inter-electrode distance or spacing.
Collapse
Affiliation(s)
- Katelyn A Berg
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - Jack H Noble
- Department of Electrical Engineering and Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA
| | - Benoit M Dawant
- Department of Electrical Engineering and Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA
| | - Robert T Dwyer
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - Robert F Labadie
- Department of Otolaryngology, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - René H Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| |
Collapse
|
27
|
Shader MJ, Gordon-Salant S, Goupell MJ. Impact of Aging and the Electrode-to-Neural Interface on Temporal Processing Ability in Cochlear-Implant Users: Amplitude-Modulation Detection Thresholds. Trends Hear 2020; 24:2331216520936160. [PMID: 32833587 PMCID: PMC7448135 DOI: 10.1177/2331216520936160] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Although cochlear implants (CIs) are a viable treatment option for severe hearing loss in adults of any age, older adults may be at a disadvantage compared with younger adults. CIs deliver signals that contain limited spectral information, requiring CI users to attend to the temporal information within the signal to recognize speech. Older adults are susceptible to acquiring auditory temporal processing deficits, presenting a potential age-related limitation for recognizing speech signals delivered by CIs. The goal of this study was to measure auditory temporal processing ability via amplitude-modulation (AM) detection as a function of age in CI users. The contribution of the electrode-to-neural interface, in addition to age, was estimated using electrically evoked compound action potential (ECAP) amplitude growth functions. Within each participant, two electrodes were selected: one with the steepest ECAP slope and one with the shallowest ECAP slope, in order to represent electrodes with varied estimates of the electrode-to-neural interface. Single-electrode AM detection thresholds were measured using direct stimulation at these two electrode locations. Results revealed that AM detection ability significantly declined as a function of chronological age. ECAP slope did not significantly impact AM detection, but ECAP slope decreased (became shallower) with increasing age, suggesting that factors influencing the electrode-to-neural interface change with age. Results demonstrated a significant negative impact of chronological age on auditory temporal processing. The locus of the age-related limitation (peripheral vs. central origin), however, is difficult to evaluate because the peripheral influence (ECAPs) was correlated with the central factor (age).
Collapse
Affiliation(s)
- Maureen J Shader
- Department of Hearing and Speech Sciences, University of Maryland
| | | | | |
Collapse
|
28
|
Heshmat A, Sajedi S, Johnson Chacko L, Fischer N, Schrott-Fischer A, Rattay F. Dendritic Degeneration of Human Auditory Nerve Fibers and Its Impact on the Spiking Pattern Under Regular Conditions and During Cochlear Implant Stimulation. Front Neurosci 2020; 14:599868. [PMID: 33328872 PMCID: PMC7710996 DOI: 10.3389/fnins.2020.599868] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Accepted: 10/22/2020] [Indexed: 12/04/2022] Open
Abstract
Due to limitations of human in vivo studies, detailed computational models enable understanding the neural signaling in the degenerated auditory system and cochlear implants (CIs). Four human cochleae were used to quantify hearing levels depending on dendritic changes in diameter and myelination thickness from type I of the auditory nerve fibers (ANFs). Type I neurons transmit the auditory information as spiking pattern from the inner hair cells (IHCs) to the cochlear nucleus. The impact of dendrite diameter and degree of myelination on neural signal transmission was simulated for (1) synaptic excitation via IHCs and (2) stimulation from CI electrodes. An accurate three-dimensional human cochlear geometry, along with 30 auditory pathways, mimicked the CI environment. The excitation properties of electrical potential distribution induced by two CI were analyzed. Main findings: (1) The unimodal distribution of control dendrite diameters becomes multimodal for hearing loss cases; a group of thin dendrites with diameters between 0.3 and 1 μm with a peak at 0.5 μm appeared. (2) Postsynaptic currents from IHCs excite such thin dendrites easier and earlier than under control conditions. However, this advantage is lost as their conduction velocity decreases proportionally with the diameter and causes increased spike latency and jitter in soma and axon. Firing probability reduces through the soma passage due to the low intracellular current flow in thin dendrites during spiking. (3) Compared with dendrite diameter, variations in myelin thickness have a small impact on spiking performance. (4) Contrary to synaptic excitation, CIs cause several spike initiation sites in dendrite, soma region, and axon; moreover, fiber excitability reduces with fiber diameter. In a few cases, where weak stimuli elicit spikes of a target neuron (TN) in the axon, dendrite diameter reduction has no effect. However, in many cases, a spike in a TN is first initiated in the dendrite, and consequently, dendrite degeneration demands an increase in threshold currents. (5) Threshold currents of a TN and co-stimulation of degenerated ANFs in other frequency regions depend on the electrode position, including its distance to the outer wall, the cochlear turn, and the three-dimensional pathway of the TN.
Collapse
Affiliation(s)
- Amirreza Heshmat
- Faculty of Mathematics and Geoinformation, Institute for Analysis and Scientific Computing, Vienna University of Technology, Vienna, Austria.,Laboratory for Inner Ear Biology, Department of Otorhinolaryngology, Medical University of Innsbruck, Innsbruck, Austria
| | - Sogand Sajedi
- Faculty of Mathematics and Geoinformation, Institute for Analysis and Scientific Computing, Vienna University of Technology, Vienna, Austria
| | - Lejo Johnson Chacko
- Laboratory for Inner Ear Biology, Department of Otorhinolaryngology, Medical University of Innsbruck, Innsbruck, Austria
| | - Natalie Fischer
- Laboratory for Inner Ear Biology, Department of Otorhinolaryngology, Medical University of Innsbruck, Innsbruck, Austria
| | - Anneliese Schrott-Fischer
- Laboratory for Inner Ear Biology, Department of Otorhinolaryngology, Medical University of Innsbruck, Innsbruck, Austria
| | - Frank Rattay
- Faculty of Mathematics and Geoinformation, Institute for Analysis and Scientific Computing, Vienna University of Technology, Vienna, Austria
| |
Collapse
|
29
|
Parreño M, Di Lella FA, Fernandez F, Boccio CM, Ausili SA. Toward Self-Measures in Cochlear Implants: Daily and “Homemade” Impedance Assessment. Front Digit Health 2020; 2:582562. [PMID: 34713054 PMCID: PMC8521944 DOI: 10.3389/fdgth.2020.582562] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Accepted: 10/15/2020] [Indexed: 11/13/2022] Open
Abstract
Introduction: Cochlear implant (CI) impedance reflects the status of the electro neural interface, potentially acting as a biomarker for inner ear injury. Most impedance shifts are diagnosed retrospectively because they are only measured in clinical appointments, with unknown behavior between visits. Here we study the application and discuss the benefits of daily and remote impedance measures with software specifically designed for this purpose. Methods: We designed software to perform CI impedance measurements without the intervention of health personnel. Ten patients were recruited to self-measure impedance for 30 days at home, between CI surgery and activation. Data were transferred to a secured online server allowing remote monitoring. Results: Most subjects successfully performed measurements at home without supervision. Only a subset of measurements was missed due to lack of patient engagement. Data were successfully and securely transferred to the online server. No adverse events, pain, or discomfort was reported by participants. Discussion: This work overviews a flexible and highly configurable platform for self-measurement CI impedance. This novel approach simplifies the CI standard of care by reducing the number of clinical visits and by proving useful and constant information to CI clinicians.
Collapse
Affiliation(s)
- Matias Parreño
- Department of Otolaryngology, Hospital Italiano, Buenos Aires, Argentina
| | - Federico A. Di Lella
- Department of Otolaryngology, Hospital Italiano, Buenos Aires, Argentina
- *Correspondence: Federico A. Di Lella
| | | | - Carlos M. Boccio
- Department of Otolaryngology, Hospital Italiano, Buenos Aires, Argentina
| | - Sebastian A. Ausili
- Department of Otolaryngology, University of Miami, Coral Gables, FL, United States
- Sebastian A. Ausili
| |
Collapse
|
30
|
Di Lella FA, Parreño M, Fernandez F, Boccio CM, Ausili SA. Measuring the Electrical Status of the Bionic Ear. Re-thinking the Impedance in Cochlear Implants. Front Bioeng Biotechnol 2020; 8:568690. [PMID: 33072726 PMCID: PMC7530401 DOI: 10.3389/fbioe.2020.568690] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Accepted: 08/26/2020] [Indexed: 11/13/2022] Open
Abstract
As in any biophysical electrode-tissue environment, impedance measurement shows a complex relationship which reflects the electrical characteristics of the medium. In cochlear implants (CIs), which is mostly a stimulation-oriented device, the actual clinical approach only considers one arbitrary time-measure of the impedance. However, to determine the main electrical properties of the cochlear medium, the overall impedance and its subcomponents (i.e., access resistance and polarization impedance) should be described. We here characterized, validated and discussed a novel method to calculate impedance subcomponents based on CI measurement capabilities. With an electronic circuit of the cochlear electrode-tissue interface and its computational simulation, the access resistance and polarization impedance were modeled. Values of each electrical component were estimated through a custom-made pulse delivery routine and the acquisition of multiple data points. Using CI hardware, results fell within the electronic components nominal errors (± 10%). Considering the method’s accuracy and reliability, it is readily available to be applied in research-clinical use. In the man-machine nature of the CI, this represents the basis to optimize the communication between a CI electrode and the spiral ganglion cells.
Collapse
Affiliation(s)
| | - Matias Parreño
- Department of Otolaryngology, Hospital Italiano, Buenos Aires, Argentina
| | | | - Carlos M Boccio
- Department of Otolaryngology, Hospital Italiano, Buenos Aires, Argentina
| | - Sebastián A Ausili
- Department of Otolaryngology, University of Miami, Miami, FL, United States
| |
Collapse
|
31
|
Saoji AA, Adkins WJ, Olund AP, Graham M, Patel NS, Neff BA, Carlson ML, Driscoll CLW. Increase in cochlear implant electrode impedances with the use of electrical stimulation. Int J Audiol 2020; 59:881-888. [PMID: 32749178 DOI: 10.1080/14992027.2020.1799251] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
OBJECTIVE Electrode impedances play a critical role in cochlear implant programming. It has been previously shown that impedances rise during periods of non-use, such as the post-operative recovery period. Then when the device is activated and use is initiated, impedances fall and are typically stable. In this study, we report a new pattern where electrode impedances increase with device use and decrease with device rest. DESIGN Electrode impedances were measured three to four times every day over a span of 1-3 months for two cochlear implant patients. STUDY SAMPLE Two patients with a Nucleus cochlear implant participated in this study. RESULTS Both subjects in this study show wide fluctuations in electrode impedances. By taking serial electrode impedance measurements throughout a day of use, we observe that electrode impedances consistently increase with device use and decrease with device rest. CONCLUSION In this study, we report two cases of electrode impedances increasing as a function of device use. Numerous management strategies were employed to reduce this effect but none prevailed; a clear pathophysiologic mechanism remains elusive. Further study into the cause of this electrode impedance pattern is warranted to establish a management strategy for these cochlear implant users.
Collapse
Affiliation(s)
- Aniket A Saoji
- Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic School of Medicine, Rochester, MN, USA
| | - Weston J Adkins
- Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic School of Medicine, Rochester, MN, USA
| | - Amy P Olund
- Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic School of Medicine, Rochester, MN, USA
| | - Madison Graham
- Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic School of Medicine, Rochester, MN, USA
| | - Neil S Patel
- Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic School of Medicine, Rochester, MN, USA
| | - Brian A Neff
- Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic School of Medicine, Rochester, MN, USA
| | - Matthew L Carlson
- Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic School of Medicine, Rochester, MN, USA
| | - Colin L W Driscoll
- Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic School of Medicine, Rochester, MN, USA
| |
Collapse
|
32
|
Abstract
OBJECTIVES Preservation of residual hearing is one of the main goals in present cochlear implantation surgery. Especially for this purpose, smaller and softer electrode carriers were developed that are to be inserted through the round window membrane to minimize trauma. By using these electrodes and insertion technique, residual hearing can be preserved in a large number of patients. Unfortunately, some of these patients with initially preserved residual hearing after cochlear implantation lose it later on. The reason for this is unknown but it is speculated about a correlation with an increase in impedance, since increased impedance values are linked to intracochlear inflammation and tissue reaction. Our hypothesis for this study design was that an increase in impedance predicts changes in residual hearing under clinical conditions. DESIGN Data of all adult patients (N = 122) receiving a Hybrid-L24 cochlear implant at our center between 2005 and early 2015 were retrospectively evaluated. Impedance values in Common Ground mode as measured during clinical routine and referring audiological test data (audiometric thresholds under headphones) were collected. Changes between consecutive measurements were calculated for impedance values and hearing thresholds for each patient. Correlations between changes in impedances and acoustic hearing thresholds were calculated. Average values were compared as well as patients with largest impedance changes within the observation period were evaluated separately. RESULTS Group mean values of impedances were between 5 and 7 kΩ and stable over time with higher values on basal electrode contacts compared with apical contacts. Average hearing thresholds at the time of initial fitting were between 40 to 50 dB (250 Hz) and 90 dB (1 kHz) with a loss of about 10 dB compared with preoperative values. Correlation between impedance changes and threshold changes was found, but too inconsistently to imply a true relationship. When evaluating the 20 patients with the largest impedance changes during the observation period (all >1 kΩ from one appointment to the next one), some patients were found where hearing loss is timely connected and highly correlated with an unusual impedance change. But large impedance changes were also observed without affecting hearing thresholds and hearing loss was found without impedance change. CONCLUSIONS Changes in impedance as measured during clinical routine cannot be taken as an indicator for a late acoustic hearing loss.
Collapse
|
33
|
Abstract
BACKGROUND The perimodiolar CI532 Slim Modiolar electrode has been designed to bring the electrode contacts close to auditory nerve while reducing cochlear trauma during its insertion. It is currently unknown to what extent the electrode position and electrophysiological outcomes of the Slim Modiolar electrode differ from other perimodiolar electrodes. OBJECTIVES The objective was to compare the electrode position and electrophysiological outcomes between the CI532 Slim Modiolar and CI512 Contour Advance electrode. METHOD Forty-six adult patients received a Slim Modiolar or Contour Advance electrode. Electrode types were compared using intraoperative electrode impedances, evoked compound action potential (ECAP) and stapedius reflex thresholds, as well as position parameters from postoperative computed tomography or digital volume tomography images (medial-lateral position, electrode-to-modiolus distance, insertion angle). RESULTS The medial-lateral position indicates a closer modiolar placement of the Slim Modiolar compared with the Contour Advance. Individual electrode contact measurements, however, showed significantly larger electrode-to-modiolus distances and higher ECAP thresholds for the Slim Modiolar in the basal region. On contacts E20-22 the Slim Modiolar is slightly closer to the modiolus compared with the Contour Advance, but this did not result in lower ECAP thresholds. CONCLUSIONS Perimodiolar electrodes can vary in their intracochlear position, leading to divergent electrophysiological outcomes. To detect these differences, investigations must be done for each electrode contact rather than using a global factor for the whole electrode array. While the electrode dislocation rate is lower with the Slim Modiolar than with the Contour Advance, electrode-to-modiolus proximity is smaller and ECAP thresholds are lower with the Contour Advance in the basal cochlear region.
Collapse
|
34
|
Abstract
OBJECTIVE Characterize differences in adult cochlear implant outcomes and programming parameters for a straight (CI422/522) and a precurved (CI532) electrode array. SETTING Cochlear implant (CI) program at a tertiary otologic center. PATIENTS Fifty-eight adults were included in the study; 29 were implanted with CI422 or CI522 and 29 were implanted with CI532. Each CI532 recipient was matched to a CI422/522 recipient in terms of age and preoperative hearing thresholds for comparison purposes. MAIN OUTCOME MEASURES Consonant-Nucleus-Consonant (CNC) words, AzBio sentences, residual audiometric thresholds, and Speech Spatial Qualities (SSQ) questionnaire collected 6 months postoperatively were used to characterize outcomes. Pulse duration, maxima, impedances, and overall charge measurements were used to characterize programming parameters. RESULTS Postoperative unaided low frequency pure-tone average (LFPTA) was significantly better for the CI532 group. CNC scores were significantly better for the CI532 group. Impedances and pulse duration were significantly lower for the CI532 group, but there was no difference in overall charge between the groups. CONCLUSION The CI532 group showed either similar or statistically superior results on all measures when compared with the CI422/522 suggesting that the CI532 electrode may be an advantageous substitute for the CI522.
Collapse
|
35
|
Berg KA, Noble JH, Dawant BM, Dwyer RT, Labadie RF, Gifford RH. Speech recognition with cochlear implants as a function of the number of channels: Effects of electrode placement. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 147:3646. [PMID: 32486813 PMCID: PMC7255811 DOI: 10.1121/10.0001316] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Revised: 05/08/2020] [Accepted: 05/08/2020] [Indexed: 05/28/2023]
Abstract
This study investigated the effects of cochlear implant (CI) electrode array type and scalar location on the number of channels available to CI recipients for maximum speech understanding and sound quality. Eighteen post-lingually deafened adult CI recipients participated, including 11 recipients with straight electrode arrays entirely in scala tympani and 7 recipients with translocated precurved electrode arrays. Computerized tomography was used to determine electrode placement and scalar location. In each condition, the number of channels varied from 4 to 22 with equal spatial distribution across the array. Speech recognition (monosyllables, sentences in quiet and in noise), subjective speech sound quality, and closed-set auditory tasks (vowels, consonants, and spectral modulation detection) were measured acutely. Recipients with well-placed straight electrode arrays and translocated precurved electrode arrays performed similarly, demonstrating asymptotic speech recognition scores with 8-10 channels, consistent with the classic literature. This finding contrasts with recent work [Berg, Noble, Dawant, Dwyer, Labadie, and Gifford. (2019). J. Acoust. Soc. Am. 145, 1556-1564] that found precurved electrode arrays well-placed in scala tympani demonstrate continuous performance gains beyond 8-10 channels. Given these results, straight and translocated precurved electrode arrays are theorized to have less channel independence secondary to their placement farther away from neural targets.
Collapse
Affiliation(s)
- Katelyn A Berg
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - Jack H Noble
- Department of Electrical Engineering & Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA
| | - Benoit M Dawant
- Department of Electrical Engineering & Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA
| | - Robert T Dwyer
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - Robert F Labadie
- Department of Otolaryngology, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - René H Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| |
Collapse
|
36
|
Comparison of electrophysiological parameters between perimodiolar and lateral wall electrodes in paediatric cochlear implant users. Eur Arch Otorhinolaryngol 2020; 277:2693-2699. [DOI: 10.1007/s00405-020-05927-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Accepted: 03/16/2020] [Indexed: 11/26/2022]
|
37
|
Speech Perception Outcomes for Adult Cochlear Implant Recipients Using a Lateral Wall or Perimodiolar Array. Otol Neurotol 2020; 40:608-616. [PMID: 31083082 DOI: 10.1097/mao.0000000000002189] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
AIM To assess the speech perception outcomes of adult CI recipients with significant preimplant low frequency hearing, examining differences between perimodiolar and lateral wall electrode placement in order to provide clinical guidance for clinicians and surgeons. METHODS A prospective cohort study was undertaken identifying all adults who received a thin straight electrode array (TSEA) at the Royal Victorian Eye & Ear Hospital (RVEEH) from 2010 to 2015 and who had a preimplant low frequency pure tone median ≤70 dB HL (n = 63). A retrospective review was completed of the RVEEH database to identify a comparison group who had been implanted with a perimodiolar electrode array, comprising adults implanted between 2004 and 2011 (PM Group) with preimplant hearing equivalent to the TSEA group (n = 70). The TSEA Group were further divided into subgroups in which n = 19 used EAS (TSEA-EAS) and n = 44 who used electric-only hearing (TSEA-Standard). RESULTS There was no significant difference in median speech perception outcomes between the TSEA and PM Groups (TSEA 61.7%, PM 67.3%, p = 0.954). A significant difference was found between the TSEA-EAS and TSEA-Standard subgroups for median speech perception outcome (TSEA-EAS median 73.5%, TSEA-Standard median 58.3%, p = 0.043). CONCLUSIONS Significant speech perception benefit following cochlear implantation was achieved with both the perimodiolar and lateral wall electrode arrays and no significant difference was found between outcomes with those array types in this population of adults with functional low frequency hearing pre-implant. Those that received a TSEA, had preserved hearing, and utilised an EAS sound processor performed better than their peers with a TSEA and electric-only hearing.
Collapse
|
38
|
Polarity Sensitivity as a Potential Correlate of Neural Degeneration in Cochlear Implant Users. J Assoc Res Otolaryngol 2020; 21:89-104. [PMID: 32020417 DOI: 10.1007/s10162-020-00742-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2019] [Accepted: 01/16/2020] [Indexed: 12/19/2022] Open
Abstract
Cochlear implant (CI) performance varies dramatically between subjects. Although the causes of this variability remain unclear, the electrode-neuron interface is thought to play an important role. Here we evaluate the contribution of two parameters of this interface on the perception of CI listeners: the electrode-to-modiolar wall distance (EMD), estimated from cone-beam computed tomography (CT) scans, and a measure of neural health. Since there is no objective way to quantify neural health in CI users, we measure stimulus polarity sensitivity, which is assumed to be related to neural degeneration, and investigate whether it also correlates with subjects' performance in speech recognition and spectro-temporal modulation detection tasks. Detection thresholds were measured in fifteen CI users (sixteen ears) for partial-tripolar triphasic pulses having an anodic or a cathodic central phase. The polarity effect was defined as the difference in threshold between cathodic and anodic stimuli. Our results show that both the EMD and the polarity effect correlate with detection thresholds, both across and within subjects, although the within-subject correlations were weak. Furthermore, the mean polarity effect, averaged across all electrodes for each subject, was negatively correlated with performance on a spectro-temporal modulation detection task. In other words, lower cathodic thresholds were associated with better spectro-temporal modulation detection performance, which is also consistent with polarity sensitivity being a marker of neural degeneration. Implications for the design of future subject-specific fitting strategies are discussed.
Collapse
|
39
|
Needham K, Stathopoulos D, Newbold C, Leavens J, Risi F, Manouchehri S, Durmo I, Cowan R. Electrode impedance changes after implantation of a dexamethasone-eluting intracochlear array. Cochlear Implants Int 2019; 21:98-109. [DOI: 10.1080/14670100.2019.1680167] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Affiliation(s)
- Karina Needham
- The HEARing CRC, Carlton, Australia
- Department of Audiology and Speech Pathology, The University of Melbourne, Carlton, Australia
- Otolaryngology, Department of Surgery, The University of Melbourne, East Melbourne, Australia
| | - Dimitra Stathopoulos
- The HEARing CRC, Carlton, Australia
- Department of Audiology and Speech Pathology, The University of Melbourne, Carlton, Australia
| | - Carrie Newbold
- The HEARing CRC, Carlton, Australia
- Department of Audiology and Speech Pathology, The University of Melbourne, Carlton, Australia
- Otolaryngology, Department of Surgery, The University of Melbourne, East Melbourne, Australia
| | - Jason Leavens
- Cochlear Ltd, Macquarie University, Sydney, Australia
| | - Frank Risi
- Cochlear Ltd, Macquarie University, Sydney, Australia
| | | | - Irfan Durmo
- Cochlear Ltd, Macquarie University, Sydney, Australia
| | - Robert Cowan
- The HEARing CRC, Carlton, Australia
- Department of Audiology and Speech Pathology, The University of Melbourne, Carlton, Australia
| |
Collapse
|
40
|
Electrophysiological detection of electrode fold-over in perimodiolar cochlear implant electrode arrays: a multi-center study case series. Eur Arch Otorhinolaryngol 2019; 277:31-35. [PMID: 31552525 DOI: 10.1007/s00405-019-05653-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Accepted: 09/12/2019] [Indexed: 10/26/2022]
Abstract
PURPOSE It is important for the surgeon to determine the position of the CI electrode array during and after its placement within the cochlea. Most preferably, this should be within the scala tympani to obtain the best audiological outcome. Thus, misplacement into the scala vestibuli or tip fold-over should be prevented. Since there are different ways to ensure proper positioning of the electrode array within the scala tympani (e.g., intraoperative radiography, electrophysiological recordings), our study was aimed at detecting intraoperative electrophysiologic characteristics to better understand the mechanisms of those electrode tip fold-overs. MATERIAL AND METHODS In a multi-centric, retrospective case-control series, patients with a postoperatively by radiography detected tip fold-over in perimodiolar electrodes were included. The point of fold-over (i.e., the electrode position) was determined and the intraoperative Auto-NRT recordings were analysed and evaluated. RESULTS Four patients were found to have an electrode tip fold-over (out of 85 implantees). Significant changes of the Auto-NRT recordings were not detected. All tip fold-overs occurred in the most apical part of the electrodes. DISCUSSION Cochlear implantation for hearing impaired patients plays a decisive role in modern auditory rehabilitation. Perimodiolar electrode arrays may fold over during the insertion and, hence, could have a negative impact on audiological outcome. Characteristic electrophysiologic changes to possibly predict this were not found in our series.
Collapse
|
41
|
Risi F. Considerations and Rationale for Cochlear Implant Electrode Design - Past, Present and Future. J Int Adv Otol 2019; 14:382-391. [PMID: 30644379 DOI: 10.5152/iao.2018.6372] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
The electrode array of a cochlear implant forms a permanent, often lifelong interface between the implanted electronics and neural structures of the cochlea. A cochlear implant is primarily prescribed to restore hearing via electrical stimulation of the auditory nerve. As with any neural stimulator intended to either deliver electrical stimulus or record a neural response, the aim is to place the electrodes in close proximity to the target neural structures. The broadening of indications and the concept of preservation of low-frequency residual hearing over the last two decades has resulted in an increased understanding of the mechanisms and implications of intracochlear trauma for both the hearing preservation surgery and electrical stimulation outcomes with cochlear implantation, as well as the influence of many biographic and audiological patient factors correlated with achieving better hearing outcomes. These two goals, the proximity to the cochlear nerve for electrical stimulation and the preservation of cochlear structures, have typically been viewed as mutually exclusive, with perimodiolar electrode arrays being preferred for the former, and lateral wall electrode arrays for the latter. The design evolution of both the lateral wall and perimodiolar electrodes is presented, considering the cochlea anatomy and continued understanding of the mechanics and dynamics of electrode insertion, along with the influence of the ongoing changes to the intracochlear environment to provide a rationale for the electrode design with the intent to provide the greatest patient benefit over their implanted lifetime.
Collapse
Affiliation(s)
- Frank Risi
- Group Product Manager, Surgical - Implants, Cochlear Limited, New South Wales, Australia
| |
Collapse
|
42
|
Lee JY, Hong SH, Moon IJ, Kim EY, Baek E, Seol HY, Kang S. Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types. J Audiol Otol 2019; 23:145-152. [PMID: 31315391 PMCID: PMC6646897 DOI: 10.7874/jao.2019.00164] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2019] [Accepted: 06/04/2019] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND AND OBJECTIVES The present study aims to investigate whether the cochlear implant electrode array design affects the electrophysiological and psychophysical measures. SUBJECTS AND METHODS Eighty five ears were used as data in this retrospective study. They were divided into two groups by the electrode array design: lateral wall type (LW) and perimodiolar type (PM). The electrode site was divided into three regions (basal, medial, apical). The evoked compound action potential (ECAP) threshold, T level, C level, dynamic range (DR), and aided air conduction threshold were measured. RESULTS The ECAP threshold was lower for the PM than for the LW, and decreased as the electrode site was closer to the apical region. The T level was lower for the PM than for the LW, and was lower on the apical region than on the other regions. The C level on the basal region was lower for the PM than for the LW whereas the C level was lower on the apical region than on the other regions. The DRs on the apical region was greater for the PM than for the LW whereas the DR was narrower on the apical region than on the other regions. The aided air conduction threshold was not different for the electrode design and frequency. CONCLUSIONS The current study would support the advantages of the PM over the LW in that the PM had the lower current level and greater DR, which could result in more localized neural stimulation and reduced power consumption.
Collapse
Affiliation(s)
- Ji Young Lee
- Department of Audiology and Speech-Language Pathology, Daegu Catholic University, Gyeongsan, Korea
| | - Sung Hwa Hong
- Department of Otorhinolaryngology-Head and Neck-Surgery, Samsung Changwon Hospital, School of Medicine, Sungkyunkwan University, Changwon, Korea
| | - Il Joon Moon
- Department of Otorhinolaryngology-Head and Neck-Surgery, Samsung Medical Center, School of Medicine, Sungkyunkwan University, Seoul, Korea.,Hearing Research Laboratory of Samsung Medical Center-Samsung Electronics Co., Seoul, Korea
| | - Eun Yeon Kim
- Department of Speech-Language Pathology, Graduate School of Social Education, Myongji University, Seoul, Korea
| | - Eunjoo Baek
- Department of Otorhinolaryngology-Head and Neck-Surgery, Samsung Medical Center, School of Medicine, Sungkyunkwan University, Seoul, Korea
| | - Hye Yoon Seol
- Hearing Research Laboratory of Samsung Medical Center-Samsung Electronics Co., Seoul, Korea.,Sungkyunkwan University Samsung Advanced Institute for Health Sciences and Technology, Seoul, Korea
| | - Sihyung Kang
- Department of Otorhinolaryngology-Head and Neck-Surgery, Samsung Changwon Hospital, School of Medicine, Sungkyunkwan University, Changwon, Korea
| |
Collapse
|
43
|
Electrical Impedance as a Biomarker for Inner Ear Pathology Following Lateral Wall and Peri-modiolar Cochlear Implantation. Otol Neurotol 2019; 40:e518-e526. [DOI: 10.1097/mao.0000000000002227] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
44
|
The Pull-Back Technique for the 532 Slim Modiolar Electrode. BIOMED RESEARCH INTERNATIONAL 2019; 2019:6917084. [PMID: 31240221 PMCID: PMC6556256 DOI: 10.1155/2019/6917084] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/26/2019] [Revised: 04/14/2019] [Accepted: 04/28/2019] [Indexed: 11/18/2022]
Abstract
Introduction The distance between the modiolus and the electrode array is one factor that has become the focus of many discussions and studies. Positioning the electrode array closer to the spiral ganglion with the goal of reducing the current spread has been shown to improve hearing outcomes. The perimodiolar electrode arrays can be complemented with a surgical manoeuvre called the pull-back technique. This study focuses its attention on the recently developed 532 slim modiolar electrode. Objective To investigate the intracochlear movements and pull-back technique for the 532 slim modiolar electrode. Material and Methods A decapping procedure of the cochlea was performed on 5 temporal bones. The electrode array was inserted, and the intracochlear movements were microscopically examined and digitally captured. Three situations were analysed: the initial insertion, the overinsertion, and the pull-back position. The position of the three white markers of the electrode array in relation to the round window (RW) was evaluated while performing these three actions. Results The initial insertion achieved an acceptable perimodiolar position of the electrode array, but a gap was still observed between the mid-portion of the array and the modiolus (the first white marker was seen in the RW). When we inserted the electrode more deeply, the mid-portion of the array was pushed away from the modiolus (the second and third white markers were seen in the RW). After applying the pull-back technique, the gap observed during the initial insertion disappeared, resulting in an optimal perimodiolar position (the first white marker was once again visible in the RW). Conclusion This temporal bone study demonstrated that when applying the pull-back technique for the 532 slim modiolar electrode, a closer proximity to the modiolus was achieved when the first white marker of the electrode array was visible in the round window.
Collapse
|
45
|
Gomez Serrano M, Patel S, Harris R, Selvadurai D. Initial surgical and clinical experience with the Nucleus CI532 slim modiolar electrode in the UK. Cochlear Implants Int 2019; 20:207-216. [PMID: 30947632 DOI: 10.1080/14670100.2019.1597461] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
OBJECTIVE The goal of this work is to describe the first experience in the UK with the slim pre-curved perimodiolar electrode Nucleus CI532 in a continuous series of patients in terms of surgical and clinical reliability and early performance outcomes. METHOD In this retrospective review we describe the complication rate (including electrode array tip fold-over), NRT thresholds, hearing preservation, power efficiency and CI performance outcomes in a continuous series of 40 cochlear implants CI532 performed between October 2016 and November 2017 in 17 adults and 13 children with severe to profound hearing loss. RESULTS Preliminary data from these groups reveals some low-frequency hearing preservation in the CI532 group although none of the patients were conventional hearing preservation candidates. NRT thresholds, power efficiency, and BKB sentences in quiet were measured at 3 and 6 months post activation. There were no significant differences in these results. The average BKB score in quiet increases from 22% pre-operatively to 58% at 3 months and 70% at 6 months. In addition, although hearing preservation was not an objective, low-frequency thresholds were preserved in 20% of cases at 3 and 6 months post-operatively. Complications were observed in 5 cases, one case with non-device related aerocoele and four related to the device array: two cases of tip roll over, one case of the electrode array being placed extra-cochlea, and one case with the electrode buckling into the middle ear. The last 2 cases were dealt with per-operatively. DISCUSSION Our preliminary results with the CI532 implant indicate that it may be reliably placed with standard surgical techniques but care is needed during the deployment of the electrode. Further initial data suggest that switch on and early electrophysiological measures are comparable to the existing CI 512 device. However whilst preliminary, our data suggest that it may be possible to use this electrode for hearing preservation. However, further studies are required to determine its definitive advantage over other electrode designs. CONCLUSION CI532 is a reliable device offering good initial results and could be an option for hearing preservation although further studies are required.
Collapse
Affiliation(s)
- Manuel Gomez Serrano
- a St George's Auditory Implant Service, St Georges NHS Foundation Trust London , London , UK
| | - Sharmila Patel
- a St George's Auditory Implant Service, St Georges NHS Foundation Trust London , London , UK
| | - Robert Harris
- a St George's Auditory Implant Service, St Georges NHS Foundation Trust London , London , UK
| | - David Selvadurai
- a St George's Auditory Implant Service, St Georges NHS Foundation Trust London , London , UK
| |
Collapse
|
46
|
Sanderson AP, Rogers ETF, Verschuur CA, Newman TA. Exploiting Routine Clinical Measures to Inform Strategies for Better Hearing Performance in Cochlear Implant Users. Front Neurosci 2019; 12:1048. [PMID: 30697145 PMCID: PMC6340939 DOI: 10.3389/fnins.2018.01048] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Accepted: 12/24/2018] [Indexed: 11/21/2022] Open
Abstract
Neuroprostheses designed to interface with the nervous system to replace injured or missing senses can significantly improve a patient's quality of life. The challenge remains to provide implants that operate optimally over several decades. Changes in the implant-tissue interface may precede performance problems. Tools to identify and characterize such changes using existing clinical measures would be highly valuable. Modern cochlear implant (CI) systems allow easy and regular measurements of electrode impedance (EI). This measure is routinely performed as a hardware integrity test, but it also allows a level of insight into the immune-mediated response to the implant, which is associated with performance outcomes. This study is a 5-year retrospective investigation of MED-EL CI users at the University of Southampton Auditory Implant Service including 176 adult ears (18-91) and 74 pediatric ears (1-17). The trend in EI in adults showed a decrease at apical electrodes. An increase was seen at the basal electrodes which are closest to the surgery site. The trend in the pediatric cohort was increasing EI over time for nearly all electrode positions, although this group showed greater variability and had a smaller sample size. We applied an outlier-labeling rule to statistically identify individuals that exhibit raised impedance. This highlighted 14 adult ears (8%) and 3 pediatric ears (5%) with impedance levels that deviated from the group distribution. The slow development of EI suggests intra-cochlear fibrosis and/or osteogenesis as the underlying mechanism. The usual clinical intervention for extreme impedance readings is to deactivate the relevant electrode. Our findings highlight some interesting clinical contradictions: some cases with raised (but not extreme) impedance had not prompted an electrode deactivation; and many cases of electrode deactivation had been informed by subjective patient reports. This emphasizes the need for improved objective evidence to inform electrode deactivations in borderline cases, for which our outlier-labeling approach is a promising candidate. A data extraction and analysis protocol that allows ongoing and automated statistical analysis of routinely collected data could benefit both the CI and wider neuroprosthetics communities. Our approach provides new tools to inform practice and to improve the function and longevity of neuroprosthetic devices.
Collapse
Affiliation(s)
- Alan P. Sanderson
- Institute of Sound and Vibration Research, Faculty of Engineering and the Environment, University of Southampton, Southampton, United Kingdom
| | - Edward T. F. Rogers
- Institute for Life Sciences and Optoelectronics Research Centre, University of Southampton, Southampton, United Kingdom
| | - Carl A. Verschuur
- Auditory Implant Service, Faculty of Engineering and the Environment, University of Southampton, Southampton, United Kingdom
| | - Tracey A. Newman
- Clinical Neurosciences, Institute for Life Sciences, Faculty of Medicine, University of Southampton, Southampton, United Kingdom
| |
Collapse
|
47
|
Giardina CK, Krause ES, Koka K, Fitzpatrick DC. Impedance Measures During in vitro Cochlear Implantation Predict Array Positioning. IEEE Trans Biomed Eng 2019; 65:327-335. [PMID: 29346102 DOI: 10.1109/tbme.2017.2764881] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVE Improper electrode placement during cochlear implant (CI) insertion can adversely affect speech perception outcomes. However, the intraoperative methods to determine positioning are limited. Because measures of electrode impedance can be made quickly, the goal of this study was to assess the relationship between CI impedance and proximity to adjacent structures. METHODS An Advanced Bionics CI array was inserted into a clear, plastic cochlea one electrode contact at a time in a saline bath (nine trials). At each insertion depth, response to biphasic current pulses was used to calculate access resistance (Ra), polarization resistance (Rp), and polarization capacitance (Cp). These measures were correlated to actual proximity as assessed by microscopy using linear regression models. RESULTS Impedance increased with insertion depth and proximity to the inner wall. Specifically, Ra increased, Cp decreased, and Rp slightly increased. Incorporating all impedance measures afforded a prediction model (r = 0.88) while optimizing for sub-mm positioning afforded a model with 78.3% specificity. CONCLUSION Impedance in vitro greatly changes with electrode insertion depth and proximity to adjacent structures in a predicable manner. SIGNIFICANCE Assessing proximity of the CI to adjacent structures is a significant first step in qualifying the electrode-neural interface. This information should aid in CI fitting, which should help maximize hearing and speech outcomes with a CI. Additionally, knowledge of the relationship between impedance and positioning could have utility in other tissue implants in the brain, retina, or spinal cord.
Collapse
|
48
|
Galvin KL, Abdi R, Dowell RC, Nayagam B. A Comparison of Electrical Stimulation Levels Across Ears for Children With Sequential Bilateral Cochlear Implants. Ear Hear 2019; 40:1174-1186. [DOI: 10.1097/aud.0000000000000702] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
49
|
RETRACTED ARTICLE: Cochlear implant device activation after 7 days in cochlear implant recipients. Eur Arch Otorhinolaryngol 2019; 276:281. [DOI: 10.1007/s00405-018-5129-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Accepted: 09/11/2018] [Indexed: 10/28/2022]
|
50
|
Hey M, Wesarg T, Mewes A, Helbig S, Hornung J, Lenarz T, Briggs R, Marx M, Ramos A, Stöver T, Escudé B, James CJ, Aschendorff A. Objective, audiological and quality of life measures with the CI532 slim modiolar electrode. Cochlear Implants Int 2018; 20:80-90. [DOI: 10.1080/14670100.2018.1544684] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Matthias Hey
- Universitätsklinikum Schleswig-Holstein, Kiel, Germany
| | | | | | - Silke Helbig
- Klinikum der J. W. Goethe-Universität, Frankfurt, Germany
| | | | | | | | - Mathieu Marx
- Centre Hospitalier Universitaire de Toulouse, Toulouse, France
| | - Angel Ramos
- Complejo Hospitalario Universitario Insular Materno Infantil, Las Palmas, Spain
| | - Timo Stöver
- Klinikum der J. W. Goethe-Universität, Frankfurt, Germany
| | | | - Chris J. James
- Centre Hospitalier Universitaire de Toulouse, Toulouse, France
- Cochlear France SAS, Toulouse, France
| | | |
Collapse
|