1
|
Gaillard-Campbell D, Gross T. Magnum metal-on-metal uncemented total hip replacement: 8- to 18-year outcomes of 211 cases. Musculoskelet Surg 2024:10.1007/s12306-024-00831-3. [PMID: 38833069 DOI: 10.1007/s12306-024-00831-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Accepted: 05/17/2024] [Indexed: 06/06/2024]
Abstract
BACKGROUND Reports of adverse reactions to metal debris contributed in part to a decline in use of large-bearing metal-on-metal total hip devices. We hypothesize an optimal trunnion design may reduce risk of this failure mode in large-bearing total hip arthroplasty systems. The purpose of this study is to report mid- to long-term outcomes for a single-surgeon series of 211 total hip arthroplasties using the large-bearing Biomet Magnum metal-on-metal system. MATERIALS AND METHODS Between December 2004 and January 2016, the primary surgeon performed 211 uncemented Magnum total hip arthroplasties in 181 patients. The average length of follow-up was 10.1 ± 3.5 years (range 8-18 years). RESULTS Using failure of any component as the endpoint, the overall survivorship rate was 98.1% at 10 years and 97.4% at 18 years. These eight failures (3.8% of cohort) included one case of adverse wear-related failure (0.5%), two cases of acetabular ingrowth failure (0.9%), three cases of trunnion corrosion (1.4%), one failure of late infection (0.5%), and one inappropriate revision of components for trochanteric nonunion without instability (0.5%). Excluding failed cases, all components were radiographically stable with no radiolucencies. Except for the one wear failure, ion testing revealed that 97.2% of cases were within optimal whole blood metal ion levels with the remaining ion test results within acceptable levels. CONCLUSIONS With the uncemented Magnum metal-on-metal total hip, we achieved 97.4% 18-year implant survivorship, exceeding the NICE criteria and registry benchmarks for implant survivorship. We observed a trunnion corrosion rate of 1.4% and no cases of instability. The single case of adverse wear-related failure was caused by acetabular component malposition.
Collapse
Affiliation(s)
- D Gaillard-Campbell
- Midlands Orthopaedics and Neurosurgery, PA, 1910 Blanding Street, Columbia, SC, 29201, USA.
| | - T Gross
- Midlands Orthopaedics and Neurosurgery, PA, 1910 Blanding Street, Columbia, SC, 29201, USA
| |
Collapse
|
2
|
Murylev VY, Elizarov PM, Muzychenkov AV, Rukin YA, Kukovenko GA, Alekseev SS, Elizarov MP. Сomparative analysis of large diameter bearing ceramic monoblock acetabular components. J Orthop 2022; 34:67-73. [PMID: 36035201 PMCID: PMC9411175 DOI: 10.1016/j.jor.2022.08.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 08/07/2022] [Indexed: 10/31/2022] Open
Abstract
Introduction The goal of total hip arthroplasty (THA) is to provide ease to patients with persistent and exhausting pain. Durability is the main challenge associated with any tribological pair, with the aim of minimizing wear and thus avoiding problems with aseptic loosening of components and osteolysis. When polyethylene inserts are used in young patients, we should always consider their disadvantages, e.g., increased wear of the interacting components. Proper selection of friction pairs allows prolonged implant life. Ceramic-on-ceramic (CoC) friction pairs should provide long-term wear of the friction components. Objectives To evaluate the mid-term results of using the monoblock Maxera Cup (Zimmer Biomet) acetabular system in cementless THA. Methods We operated on 151 patients using the monoblock Maxera Cup (Zimmer Biomet) acetabular system. The mean follow-up duration was 6 years (73.8 ± 11.7 months). Fifty-seven women and 94 men aged 19-64 years were surgically treated. All 170 THA cases in 151 patients were divided into 3 groups according to the diameters of the CoC friction pairs used (40, 44, and 48 mm). As a control group, we have taken 50 patients who received 50 THA using a standard 36 mm CoC friction pair. The achieved functional results were evaluated using the HHS scale, WOMAC scale, and SF36 scale. We also evaluated the mean duration of surgical intervention and blood loss. Results When assessing long-term results, the average HHS significantly increased from 34.10 (before surgery) to 87.50 (postoperation) points in the 1st group, from 46.24 to 96.5 points in the 2nd group, and from 38.70 to 92.10 points in the 3rd group. From preoperative examination to 1 year after surgery, there was a 2.4-fold improvement in the functional results in group 1 and 1,8 and 2.9 -fold improvement in groups 2 and 3, indicating excellent treatment results. Inconsistent creaking in the implanted joint was noted in only 2.6% of cases in which a CoC friction pair with a diameter of 44 mm was used. We did not observe any complications associated with aseptic or septic loosening of the components either clinically or radiologically during the 7-year follow-up period after surgery in the entire patient population. Conclusions 1Use of the CoC monoblock allowed us to expect an increase in the life cycle of the implant and provided good joint function and perception by the patient.2Monoblock cups provided good joint function and perception by the patient.3Acoustic effects, in the form of minor creaking, did not affect the functional results.
Collapse
Affiliation(s)
- Valery Yu Murylev
- First Moscow State Medical University named after I.M. Sechenov (Sechenov University), Ministry of Health of Russia St. Trubetskaya, 8/2, 119991, Moscow, Russia
- GBUZ City Clinical Hospital. S.P. Botkin of the Moscow Department of Health, 2nd Botkinsky pr-d, 5, 125284, Moscow, Russia
| | - Pavel M. Elizarov
- First Moscow State Medical University named after I.M. Sechenov (Sechenov University), Ministry of Health of Russia St. Trubetskaya, 8/2, 119991, Moscow, Russia
- GBUZ City Clinical Hospital. S.P. Botkin of the Moscow Department of Health, 2nd Botkinsky pr-d, 5, 125284, Moscow, Russia
| | - Aleksei V. Muzychenkov
- First Moscow State Medical University named after I.M. Sechenov (Sechenov University), Ministry of Health of Russia St. Trubetskaya, 8/2, 119991, Moscow, Russia
- GBUZ City Clinical Hospital. S.P. Botkin of the Moscow Department of Health, 2nd Botkinsky pr-d, 5, 125284, Moscow, Russia
| | - Yaroslav A. Rukin
- First Moscow State Medical University named after I.M. Sechenov (Sechenov University), Ministry of Health of Russia St. Trubetskaya, 8/2, 119991, Moscow, Russia
| | - Grigory A. Kukovenko
- First Moscow State Medical University named after I.M. Sechenov (Sechenov University), Ministry of Health of Russia St. Trubetskaya, 8/2, 119991, Moscow, Russia
- GBUZ City Clinical Hospital. S.P. Botkin of the Moscow Department of Health, 2nd Botkinsky pr-d, 5, 125284, Moscow, Russia
| | - Semen S. Alekseev
- GBUZ City Clinical Hospital. S.P. Botkin of the Moscow Department of Health, 2nd Botkinsky pr-d, 5, 125284, Moscow, Russia
| | - Michail P. Elizarov
- First Moscow State Medical University named after I.M. Sechenov (Sechenov University), Ministry of Health of Russia St. Trubetskaya, 8/2, 119991, Moscow, Russia
| |
Collapse
|
3
|
Warschawski Y, Morgan S, Garceau SP, Kuzyk PR, Safir OA, Gross AE. Does Revision of an Acetabular Shell With Insertion of an Uncemented Constrained Liner Confer Benefit Over Cementing Into a Well-Ingrown Shell? J Arthroplasty 2022; 37:1631-1635. [PMID: 35358646 DOI: 10.1016/j.arth.2022.03.065] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 03/13/2022] [Accepted: 03/18/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND During revision total hip arthroplasty (THA), a constrained acetabular liner (CAL) may be inserted to enhance hip stability. It is unclear, however, whether cementation of a CAL into a retained cup offers an advantage compared to revision of the acetabular cup and insertion of an uncemented CAL. The purpose of our study was to compare outcomes and survivorship between the 2 methods. METHODS We identified a total of 177 patients who underwent revision THA with a specific CAL at our center between July 2004 and May 2019 (114 cup revisions and insertion of an uncemented CAL, 63 cementations of a CAL into a retained cup). Kaplan-Meier (KM) survival analysis was performed for implant survival free from aseptic failure of the CAL for both cohorts. RESULTS The average follow-up time was 7.2 and 7.02 years for the cemented and uncemented cohort, respectively (P = .55). Five patients (7.93%) in the cemented CAL group experienced failure of the CAL, whereas 10 patients (8.77%) in the uncemented CAL cohort experienced failure (P = .21). Kaplan-Meier (KM) survival analysis demonstrated comparable survivorship at 10 years (P = .055). CONCLUSION The results of our study suggest comparable survivorship between cementing a CAL into a retained cup and inserting an uncemented CAL in a revised acetabular cup. As a result of these findings along with the benefits associated with cementing a CAL, we encourage surgeons to readily consider this option in the management of recurrent instability.
Collapse
Affiliation(s)
- Yaniv Warschawski
- Division of Orthopedics, Affiliated to the Sackler Faculty of Medicine, Tel Aviv Sourasky Medical Center, Tel Aviv University, Tel Aviv, Israel
| | - Samuel Morgan
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Simon P Garceau
- Department of Orthopedic, The Ottawa Hospital - General Campus, Ottawa, Canada
| | - Paul R Kuzyk
- Mount Sinai Hospital, Division of Orthopaedics, Joseph and Wolf Lebovic Health Complex, Toronto, ON, Canada
| | - Oleg A Safir
- Mount Sinai Hospital, Division of Orthopaedics, Joseph and Wolf Lebovic Health Complex, Toronto, ON, Canada
| | - Allan E Gross
- Mount Sinai Hospital, Division of Orthopaedics, Joseph and Wolf Lebovic Health Complex, Toronto, ON, Canada
| |
Collapse
|
4
|
Hip stability parameters with dual mobility, modular dual mobility and fixed bearing in total hip arthroplasty: an analytical evaluation. BMC Musculoskelet Disord 2022; 23:373. [PMID: 35443656 PMCID: PMC9022332 DOI: 10.1186/s12891-022-05280-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Accepted: 03/30/2022] [Indexed: 11/17/2022] Open
Abstract
Background Use of dual mobility (DM) in total hip arthroplasty has gained popularity due to the ability to reduce dislocation through increased jumping distance and impingement-free arc of movement. Recently, modular dual mobility (modDM) systems were introduced to give the possibility to use DM with standard metal-backed shells, however few has been studied to date regarding how jumping distance and the center of rotation change with modDM. The objective of this study was to evaluate, through analytical simulation, how jumping distance, center of rotation and arc of movement change between DM and standard cups with modDM or fixed bearings (FB). Methods 3D-models of DM and standard press-fit cups with modDM or FB liners were used to simulate DM, modDM and FB implant configurations, matched for same cup size, according to same cup position and different femoral head diameters. Jumping distance was calculated and center of rotation lateralization and oscillation angles were measured for each size of these three implant configurations. Results Jumping distance with modDM was reduced by -3.9 mm to -8.6 mm in comparison with DM, from 48 to 64 mm size, but resulted comparable to polyethylene 36 mm FB and increased by + 1.1 mm and + 1.4 mm than ceramic 36 and 40 mm FBs for sizes > 54 mm. ModDM lateralized the center of rotation up to + 2.5 mm and + 4.0 mm in comparison with DM and FBs, respectively. Oscillation angle with modDM resulted higher than + 16°, + 23°, + 17° and + 14° in comparison to DM, 28 mm, 32 mm and 36 mm FB cups, respectively, for 56 mm cup size. Conclusions According to its specific design, modDM might change hip stability parameters in comparison to DM, worsening jumping distance and center of rotation position, but increasing arc of movement. As not restoring stability parameters in the same fashion, modDM implants should be properly used when DM cups are not feasible.
Collapse
|
5
|
Kay A, Klavas D, Haghshenas V, Phan M, Le D. Two year follow up of supercapsular percutaneously assisted total hip arthroplasty. BMC Musculoskelet Disord 2021; 22:478. [PMID: 34030681 PMCID: PMC8147097 DOI: 10.1186/s12891-021-04351-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2020] [Accepted: 05/10/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Dislocation after primary total hip arthroplasty (THA) has an incidence of 2-3%. Approximately 77% of dislocations occur within the first year after surgery. The SuperPATH technique is a minimally invasive approach for THA that preserves soft tissue attachments. The purpose of this study is to describe the dislocation rate at 1 year after SuperPATH primary THA. METHODS All elective primary THAs performed by the senior author using the SuperPATH approach. Exclusion criteria were acute femoral neck fracture, revision surgery, or malignancy. There were 214 of 279 eligible patients available for telephone interviews (76.7%). Medical records were reviewed for secondary outcomes including early and late complications, cup positioning, distance ambulated on postoperative day one, discharge destination, and blood transfusions. RESULTS Mean age at surgery was 64 ± 10.8 years and mean time to telephone follow up was 773 ± 269.7 days. There were 104 female and 110 male patients. There were zero dislocations reported. Blood transfusions were performed in 3.7% of patients, and 75.7% were discharged to home at an average of 2.3 ± 1.0 days. Cup position averaged 43.6 ± 5.2° abduction and 20.9 ± 6.2° anteversion, with an average leg length discrepancy of 3.6 ± 3.32 mm. Complications included three intraoperative calcar fractures, one periprosthetic femur fracture, one early femoral revision, three superficial infections, and one instance of wound necrosis. CONCLUSION SuperPATH approach is safe for use in primary THA resulting in a low dislocation rate.
Collapse
Affiliation(s)
- Andrew Kay
- Department of Orthopedics and Sports Medicine, Houston Methodist Hospital, 6445 Fannin St. Suite 2500, Houston, TX, 77030, USA
| | - Derek Klavas
- Department of Orthopedics and Sports Medicine, Houston Methodist Hospital, 6445 Fannin St. Suite 2500, Houston, TX, 77030, USA
| | - Varan Haghshenas
- Department of Orthopedics and Sports Medicine, Houston Methodist Hospital, 6445 Fannin St. Suite 2500, Houston, TX, 77030, USA.
| | - Mimi Phan
- Texas A&M College of Medicine, 8447 Bryan Rd, Bryan, TX, 77807, USA
| | - Daniel Le
- Department of Orthopedics and Sports Medicine, Houston Methodist Willowbrook Hospital, 18220 TX-249, Houston, TX, 77070, USA
| |
Collapse
|
6
|
Sutphen SA, Lipman JD, Jerabek SA, Mayman DJ, Esposito CI. Treatment of Recurrent Dislocation after Total Hip Arthroplasty Using Advanced Imaging and Three-Dimensional Modeling Techniques: A Case Series. HSS J 2020; 16:245-255. [PMID: 33380954 PMCID: PMC7749901 DOI: 10.1007/s11420-019-09704-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Accepted: 07/01/2019] [Indexed: 02/07/2023]
Abstract
BACKGROUND Surgical treatment options for addressing recurrent dislocation after total hip arthroplasty (THA) vary. Identifying impingement mechanisms in an unstable THA may be beneficial in determining appropriate treatment. QUESTIONS/PURPOSES We sought to assess the effectiveness of developing pre-operative plans for treating hip instability after THA. We used advanced imaging and three-dimensional modeling techniques to perform impingement analyses in patients with unstable THA. METHODS We evaluated a series of eight patients who would require revision THA to treat recurrent dislocation. Using a pre-operative algorithmic approach, we built patient-specific models and evaluated hip range of motion with computed tomographic scanning and biplanar radiography. This information was used to determine a surgical treatment plan that was then executed intra-operatively. Patients were followed for 2 years to determine whether they experienced another hip dislocation following treatment. RESULTS Pre-operative kinematic modeling showed four of the eight patients had limited hip range of motion during flexion and internal rotation; a prominent anterior inferior iliac spine (AIIS) was found to limit hip range of motion in some of these cases. In the other four patients, range of motion was acceptable, suggesting soft-tissue causes of dislocation. No patients in this series experienced dislocation after undergoing revision THA. CONCLUSION Advanced modeling techniques may be useful for identifying the impingement mechanisms responsible for instability after THA. Once variables contributing to limited hip range of motion are identified, surgeons can develop treatment plans to improve patient outcomes. Resecting a hypertrophic AIIS may improve hip range of motion and may be an important consideration for hip surgeons when revising unstable THAs.
Collapse
Affiliation(s)
- Sean A. Sutphen
- Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021 USA
| | - Joseph D. Lipman
- Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021 USA
| | - Seth A. Jerabek
- Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021 USA
| | - David J. Mayman
- Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021 USA
| | | |
Collapse
|
7
|
Pedneault C, Tanzer D, Nooh A, Smith K, Tanzer M. Capsular closure outweighs head size in preventing dislocation following revision total hip arthroplasty. Hip Int 2020; 30:141-146. [PMID: 31074310 DOI: 10.1177/1120700019848107] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION The high dislocation rate following revision total hip arthroplasty (THA) has been shown to be significantly reduced by closing the posterior capsule and by the use of large diameter femoral heads. The relative importance of each of these strategies on the rate of dislocation remains unknown. We undertook a study to determine if increasing femoral head diameter, in addition to posterior capsular closure would influence the dislocation rate following revision THA. METHODS We retrospectively reviewed 144 patients who underwent a revision THA. We included all patients who underwent revision THA with closure of the posterior capsule and who had at least a 2-year minimum follow-up. 48 patients had a 28-mm femoral head, 47 had a 32-mm head and 49 patients had a 36-mm femoral head. RESULTS At a minimum follow-up of 2 years, there were 3 dislocations. There were no dislocations in the 28-mm group (0%), 2 in the 32-mm group (4%) and 1 in the 36-mm group (2%). Head size alone was not found to significantly decrease the risk of dislocation (28-mm versus 32-mm p = 0.12; 28-mm versus 36-mm p = 0.27; 32-mm versus 36-mm p = 0.40). CONCLUSION Both large diameter heads and careful attention to surgical technique with posterior capsular closure can decrease the historically high dislocation rate after revision THA when utilising the posterolateral approach. Capsular closure outweighs the effect of femoral head diameter in preventing dislocation following revision THA through a posterolateral approach.
Collapse
Affiliation(s)
| | - Dylan Tanzer
- Jo Miller Orthopaedic Laboratory, Research Institute of the McGill University, Montreal, Canada
| | - Anas Nooh
- Division of Orthopaedic Surgery, McGill University, Montreal, Canada
| | - Karen Smith
- Jo Miller Orthopaedic Laboratory, Research Institute of the McGill University, Montreal, Canada
| | - Michael Tanzer
- Division of Orthopaedic Surgery, McGill University, Montreal, Canada
| |
Collapse
|
8
|
Lack of early dislocation for dual mobility vs. fixed bearing total hip arthroplasty: A multi-center analysis of comparable cohorts. J Orthop 2020; 21:1-5. [PMID: 32071524 DOI: 10.1016/j.jor.2020.02.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Accepted: 02/02/2020] [Indexed: 02/06/2023] Open
Abstract
Background Dislocation is a major cause of morbidity and revision surgery following total hip arthroplasty (THA). To address such issues, dual mobility (DM) bearings were introduced as a more stable alternative to fixed-bearing (FB) prostheses. As such, we compared DM and FB systems in a cohort study in terms of dislocations, readmissions, and revisions. Methods A 27 multi-center retrospective review was performed of 664 DM and 218 FB cases from the same manufacturer with mean follow-up of 2.09 years and 1.83 years, respectively. Patient reported outcome measures (PROMs) including Harris Hip Score (HHS), SF12, EQ5D, and Lower Extremity Activity Score (LEAS) were evaluated as well as dislocation rates, readmissions, and revisions rates. We also performed a survivorship analysis through Kaplan-Meier estimator. Students t-test was used for normally distributed continuous data and Fisher exact test (P < 0.05) was used for discrete data. Results There were 0 dislocations in the DM (0%) group and 2 dislocations in the FB (0.92%) group (p = 0.06). Latest follow up HHS revealed a significant difference between groups (91.44 DM and 87.81 FB; p = 0.006). In addition, there was significant difference between DM and FB on SF12 Physical Component Score (PCS) (46.83 and 44.55, respectively, p = 0.015). Also, readmission rates at 30, 60 and 90 days remained lower for DM than for FB at each time point (1.05% vs. 2.75%, 1.81% vs. 2.75%, and 1.81% vs. 2.75, respectively). Overall, DM had a lower revision rate at 1.51% compared to 2.29% for FB (p = 0.24). The revision breakdown for DM revealed 0 (0%) for both Anatomic Dual Mobility (ADM) and Modular Dual Mobility (MDM) due to the acetabular component.) There was a difference, 14 (87.5%) for ADM and 2 (12.5%) due to the femoral component. The survivorship analysis revealed no significance difference between DM and FB at 4 years (97.90% and 97.26%, respectively). Conclusion In comparison to patients who undergo FB THA, DM bearings have improved PROMs and a lower rate of dislocation, readmission, and revision.
Collapse
|
9
|
MRI Evaluation of Posterior Capsular Dehiscence After Posterior Approach Total Hip Arthroplasty. J Am Acad Orthop Surg 2019; 27:e1052-e1058. [PMID: 31765329 DOI: 10.5435/jaaos-d-18-00655] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
INTRODUCTION To our knowledge, no previous study has evaluated the use of MRI to diagnose posterior capsule dehiscence after posterior approach total hip arthroplasty (THA) with capsular repair and its association with postoperative posterior hip dislocation. METHODS A retrospective chart review of patients who underwent posterior approach THA with capsulotomy repair was performed. Patients were identified who subsequently underwent MRI, and these studies were evaluated for signs of posterior capsular disruption. Each chart was then evaluated for episodes of postoperative hip dislocation. RESULTS Six hundred seventy-five patients were included in the retrospective review. Thirty-two patients (17 women [aged 37 to 78 years] and 15 men [aged 34 to 80 years]) met the inclusion criteria. Fifteen patients of 32 (48.4%) developed posterior capsule dehiscence after repair (group 1). Seventeen patients of 32 (51.6%) did not have MRI evidence of posterior capsule dehiscence (group 2). In group 1, 2 patients of 15 (13.3%) experienced a posterior hip dislocation. No group 2 patients experienced a posterior hip dislocation. Overall, only 2 patients of 32 (6.3%) developed posterior hip dislocations. In group 1, 12 patients of 15 (80%) developed dehiscence at the lateral capsule margin at the greater trochanter suture repair site. The two patients in group 1 with posterior hip dislocations displayed MRI evidence of capsular dehiscence in this region. Two patients of 15 (13.3%) in group 1 demonstrated dehiscence at the central third of the posterior capsule, whereas 1 patient of 15 (6.6%) in group 1 demonstrated dehiscence at the medial/acetabular margin. No significant difference was found between the dislocation rates between groups 1 and 2 (P = 0.212). The distribution of capsular dehiscence (lateral, middle, and medial capsule) in group 1 was significant (P = 0.0006). DISCUSSION MRI can effectively diagnose capsular dehiscence in patients who have undergone posterior THA. Most repaired capsules failed in the lateral repair region. MRI offers the potential to identify patients with a higher risk of implant dislocation. LEVEL OF EVIDENCE Therapeutic level III.
Collapse
|
10
|
Bayam L, Drampalos E, Nagai H, Kay P. Conversion of Failed Hip Hemiarthroplasty to Low Friction Arthroplasty (LFA). J Clin Med 2019; 8:jcm8040503. [PMID: 31013731 PMCID: PMC6518126 DOI: 10.3390/jcm8040503] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Revised: 03/31/2019] [Accepted: 04/10/2019] [Indexed: 01/04/2023] Open
Abstract
Purpose: We aimed to study clinical and radiological outcomes of conversion from hemiarthroplasty to Charnley hip replacement (CHR) with a particular concern over reported increased dislocation rate and literature review. Conversion of hip hemiarthroplasty to total hip replacement (THR) is a procedure reported to have high rates of complications. In the literature, there is no specific study on small head conversion. The purpose of this study was to evaluate the conversion of failed hip hemiarthroplasty to CHR with the use of modern implants. Methods: The study included 42 patients, who underwent the above procedure. The operations were carried out using a modern Charnley-type THR with a 22-mm diameter of femoral head and a trans-trochanteric approach. The mean follow-up was 75.7 months (range 25–171). Radiographs from the last follow up were evaluated for loosening and other reasons of failure. Clinical outcome was assessed using postoperative pain, function scores, complications and implant survivorship as well as radiological evaluation. Charnley’s modified pain and mobility scoring system were used for clinical and Hodgkinson and Harris’ criteria were used for radiological assessment. Results: Functionally, all of the patients showed improvement. Mean improvement in the pain level was by average of 2.4. On mobility assessment, 38 patients (90.4%) improved. Three patients (7.1%) had recurrent infections and three (4.8%) cases were treated with revision surgery and pseudarthrosis. Further complications occurred in 19.1%, not requiring operative treatment. On radiological evaluation, one (2.4%) case showed cup demarcation without bone loss, two (4.8%) cup migration, and one (2.4%) stem demarcation. Kaplan Meier survival analysis showed a survival of 90% at 96 months of follow up (95% CI (confidence interval), 60–90). Conclusion: Larger head might not be the answer to decrease the dislocation rate. Complication rates during revision of hip hemiarthroplasty to modern CHR with 22.225-mm head diameter were comparable to first-time THR revision despite having a smaller head.
Collapse
Affiliation(s)
- Levent Bayam
- Orthopaedics, Sakarya University, Sakarya 54100, Turkey.
- Orthopaedics, Manchester University Hospitals, Manchester M23 9LT, UK.
| | | | - Hajime Nagai
- Orthopaedics, Wrightington Hospital, Wigan WN6 9EP, UK.
| | - Peter Kay
- Orthopaedics, Wrightington Hospital, Wigan WN6 9EP, UK.
| |
Collapse
|
11
|
Diamond OJ, Konan S, Greidanus NV, Garbuz DS, Duncan CP, Masri BS. An Early Report of the Use of a Modular Dual Mobility Articulation in Revision Acetabular Reconstruction. J Arthroplasty 2018; 33:2961-2966. [PMID: 29807791 DOI: 10.1016/j.arth.2018.05.005] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2018] [Revised: 04/24/2018] [Accepted: 05/02/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Instability remains one of the main problems after revision hip surgery. The aim of this study was to review the clinical, radiological, and patient-reported outcomes with the use of modular dual-mobility articulation for revision acetabular reconstruction and investigate the risk of fretting corrosion by measuring serum trace metal ion levels. METHODS Sixty consecutive patients with a minimum of 24-month follow-up after the insertion of a modular dual-mobility (Stryker, Mahwah, NJ) cup at the time of revision hip surgery were identified. Follow-up included clinical and radiological patient review and functional outcome measures, and a subset of patients had their metal ion (cobalt and chromium) levels checked. RESULTS At the most recent follow-up, 5 patients had died, 3 patients have been revised because of ongoing instability, and 3 patients have had revision surgery due to infection. Overall functional outcome (mean Western Ontario and McMaster Universities Osteoarthritis Indexfunction 76, University of California, Los Angeles 5.6, mean Oxford 74.7, Short Form-12 physical 41.6/mental 53.3) and overall pain relief (mean Western Ontario and McMaster Universities Osteoarthritis Index pain score 78.3) scores were good. The mean satisfaction score was 78 of 100. The median serum trace metal chromium and cobalt levels at the most recent follow-up were 0.4 µg/L (range 0.1-6.1 µg/L) and 0.42 µg/L (range 0.21-9.42 µg/L), respectively. The survival with revision as the end point was 90%. CONCLUSIONS Dual-mobility cups with modularity represent an excellent option for the patient having revision hip surgery at high risk of instability. This series presents good patient-reported outcome measures and a low complication and revision rate.
Collapse
Affiliation(s)
- Owen J Diamond
- University of British Columbia, Department of Orthopaedics (Adult Hip and Knee Reconstruction Service), Gordon & Leslie Diamond Health Care Centre, Vancouver, British Columbia, Canada
| | - Sujith Konan
- University of British Columbia, Department of Orthopaedics (Adult Hip and Knee Reconstruction Service), Gordon & Leslie Diamond Health Care Centre, Vancouver, British Columbia, Canada
| | - Nelson V Greidanus
- University of British Columbia, Department of Orthopaedics (Adult Hip and Knee Reconstruction Service), Gordon & Leslie Diamond Health Care Centre, Vancouver, British Columbia, Canada
| | - Donald S Garbuz
- University of British Columbia, Department of Orthopaedics (Adult Hip and Knee Reconstruction Service), Gordon & Leslie Diamond Health Care Centre, Vancouver, British Columbia, Canada
| | - Clive P Duncan
- University of British Columbia, Department of Orthopaedics (Adult Hip and Knee Reconstruction Service), Gordon & Leslie Diamond Health Care Centre, Vancouver, British Columbia, Canada
| | - Bassam S Masri
- University of British Columbia, Department of Orthopaedics (Adult Hip and Knee Reconstruction Service), Gordon & Leslie Diamond Health Care Centre, Vancouver, British Columbia, Canada
| |
Collapse
|
12
|
Park SH, Lu Z, Hastings RS, Campbell PA, Ebramzadeh E. Five Hundred Fifty-five Retrieved Metal-on-metal Hip Replacements of a Single Design Show a Wide Range of Wear, Surface Features, and Histopathologic Reactions. Clin Orthop Relat Res 2018. [PMID: 29529655 PMCID: PMC6259711 DOI: 10.1007/s11999.0000000000000044] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND In 2010, a widely used metal-on-metal hip implant design was voluntarily recalled by the manufacturer because of higher than anticipated failure rates at 5 years. Although there was a large published range of revision rates, numerous studies had reported a higher risk of revision for excessive wear and associated adverse tissue reactions when compared with other metal-on-metal total hips. The reasons for this were suggested by some to be related to cup design features. QUESTIONS/PURPOSES From retrievals of ASR metal-on-metal implants and tissue samples obtained at revision surgery, we asked the following questions: (1) What were the common and uncommon surface features? (2) What were the common and uncommon linear and volumetric wear characteristics? (3) Were there common taper corrosion characteristics? (4) What aseptic lymphocytic vasculitis-associated lesion (ALVAL) features were present in the tissues? METHODS Five hundred fifty-five ASRs, including 23 resurfacings, were studied at one academic research center. Features of wear (eg, light and moderate scratching), damage (eg, deposits, gouges), and bone attachment on the porous coating were semiquantitatively ranked from 0 (none) to 3 (> 75%) based on the amount of a feature in each region of interest by the same experienced observer throughout the study. Visible features of head taper corrosion were ranked (Goldberg score) from 1 (none) to 4 (severe) by the same observer using a previously published scoring method. An experienced tribologist measured component wear depth using a coordinate measuring machine and quantified wear volume using previously validated methods. All available tissues were sampled and examined for features of ALVAL and scored from 0 to 10 by a single observer using a method they previously developed and published. A score from 0 to 4 is considered low, 5 to 8 is considered moderate, and 9 or 10 is considered high with regard to the risk of metal hypersensitivity features in the tissues. RESULTS The most common bearing surface features were light and moderate scratches and removal or postremoval damage. Discoloration and deposits were commonly observed on femoral heads (55% [305 of 553]) and less commonly on cups (30% [165 of 546]). There was no evidence of impingement or dislocation damage. There was typically a small amount of bone attachment in at least one of eight designated regions of interest (84% [460 of 546]); extensive or no bone attachment was uncommon. Edge wear was highly prevalent. The maximum wear of 469 cups (88%) occurred near the edge, whereas the maximum wear of 508 femoral heads (94%) occurred between the pole and 45° from the pole. The median combined head-cup wear volume was 14 mm (range, 1-636 mm). One hundred sixty-nine pairs (32%) had a combined wear volume of < 10 mm, 42 pairs (8%) had volumetric wear of > 100 mm, and 319 pairs (60%) had wear volume between 10 and 100 mm³. Seventy-four percent of tapers (390 of 530) received a Goldberg score of 4, 22% (116 of 530) a score of 3, < 5% (24 of 530) a score of 2, and none received a score of 1. The most frequent ALVAL score was 5 out of 10 (35 of 144 hips [24%]) and ranged from 2 (one hip) to 10 (nine hips); 92 of 144 (64%) had a moderate score, 17 of 144 (12%) had a high score, and 35 (24%) had a low score. CONCLUSIONS Although edge wear was prevalent, in most cases, this was not associated with high wear. The increased diameter and decreased coverage angle of the ASR design may have resulted in the observed high incidence of edge wear while perhaps decreasing the risk for impingement and dislocation. CLINICAL RELEVANCE The role of bearing wear in the revisions of metal-on-metal implants is controversial, because it is known that there is a large range of in vivo wear rates even within the same implant type and that patient variability affects local tissue responses to wear debris. The observations from our study of 555 retrieved ASR implant sets indicate that there was a wide range of wear including a subset with very high wear. The results suggested that the failure of the ASR and ASR XL was multifactorial, and the failure of different subgroups such as those with low wear may be the result of mechanisms other than reaction to wear debris.
Collapse
Affiliation(s)
- Sang-Hyun Park
- S.-H. Park, Z. Lu, P. A. Campbell, E. Ebramzadeh, The J. Vernon Luck, Sr, MD Orthopaedic Research Center, Orthopaedic Institute for Children and UCLA Department of Orthopaedic Surgery, Los Angeles, CA, USA R. S. Hastings, DePuy, Inc, Warsaw, IN, USA
| | | | | | | | | |
Collapse
|
13
|
Sutter EG, McClellan TR, Attarian DE, Bolognesi MP, Lachiewicz PF, Wellman SS. Outcomes of Modular Dual Mobility Acetabular Components in Revision Total Hip Arthroplasty. J Arthroplasty 2017; 32:S220-S224. [PMID: 28413142 DOI: 10.1016/j.arth.2017.03.035] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2016] [Revised: 02/18/2017] [Accepted: 03/13/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND There is a high rate of dislocation after revision total hip arthroplasty. This study evaluated the outcomes of 1 modular dual mobility component in revision total hip arthroplasty in patients at high risk of dislocation. METHODS We reviewed 64 revisions performed in 27 (42%) patients for recurrent dislocation, 16 (25%) for adverse local tissue reaction, 11 (17%) for reimplantation infection, and 10 (16%) for aseptic loosening, malposition, or fracture. Complications, reoperations, and survivorship were evaluated. RESULTS Three-year survival was 98% with failure defined as aseptic loosening and 91% with failure as cup removal for any reason. With mean follow-up time of 38 months, there were 14 complications, including 2 dislocations treated with closed reduction, 9 infections, and 12 reoperations. All complications occurred in patients revised for instability, adverse local tissue reaction, or infection. CONCLUSION The early results of this component are promising, with good overall survival and low rate of dislocation.
Collapse
Affiliation(s)
- E Grant Sutter
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - Taylor R McClellan
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - David E Attarian
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - Michael P Bolognesi
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - Paul F Lachiewicz
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - Samuel S Wellman
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| |
Collapse
|
14
|
Patnaik S, Nayak B, Sahoo AK, Sahu NK. Minimally Invasive Total Hip Replacement in an Ipsilateral Post-traumatic above-knee Amputation: A Case Report. J Orthop Case Rep 2017; 7:3-6. [PMID: 28819590 PMCID: PMC5553831 DOI: 10.13107/jocr.2250-0685.722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Introduction: Total hip replacement (THR) is a highly successful operation in alleviating pain and improving the overall function of the hip, in end-stage arthritis of the hip, in otherwise fit patients. However, THR as a surgical option in post-traumatic hip arthritis with ipsilateral above-knee amputation is rarely reported. Case Report: We are presenting a case report of a 30-year-old male, who had previously underwent an above-knee amputation due to road-traffic accident, presenting 24 h after the injury with segmental fracture femur and popliteal artery laceration, for which the limb could not be salvaged. He had an impacted anteroinferior dislocation of the ipsilateral hip with significant cartilage damage of the femoral head which required open reduction. Subsequently, he developed traumatic arthritis of the involved hip which required conversion to an uncemented THR, using a minimally invasive (MIS) anterolateral approach. The preoperative management, surgical technique, and postoperative rehabilitation are described to highlight the technical challenges, these lower limb amputees may present along with review of literature of such rare cases. Conclusion: THR in an above-knee amputee with posttraumatic hip arthritis using MIS technique is an encouraging surgical option for early functional recovery and minimizing surgical complications.
Collapse
Affiliation(s)
- Sanjeev Patnaik
- Department of Orthopaedics, Apollo Hospital, Bhubaneswar, Odisha, India
| | - Biswaranjan Nayak
- Department of Orthopaedics, Apollo Hospital, Bhubaneswar, Odisha, India
| | | | - Nabin Kumar Sahu
- Department of Orthopaedics, Apollo Hospital, Bhubaneswar, Odisha, India
| |
Collapse
|
15
|
Falez F, Papalia M, Favetti F, Panegrossi G, Casella F, Mazzotta G. Total hip arthroplasty instability in Italy. INTERNATIONAL ORTHOPAEDICS 2016; 41:635-644. [PMID: 27999925 DOI: 10.1007/s00264-016-3345-6] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2016] [Accepted: 11/09/2016] [Indexed: 01/25/2023]
Abstract
Hip dislocation is a major and common complication of total hip arthroplasty (THA), which appears with an incidence between 0.3% and 10% in primary total hip arthroplasties and up to 28% in revision THA. The hip dislocations can be classified into three groups: early, intermediate and late. Approximately two-thirds of cases can be treated successfully with a non-operative approach. The rest require further surgical intervention. The prerequisite to developing an appropriate treatment strategy is a thorough evaluation to identify the causes of the dislocation. In addition, many factors that contribute to THA dislocation are related to the surgical technique, mainly including component orientation, femoral head diameter, restoration of femoral offset and leg length, cam impingement and condition of the soft tissues. The diagnosis of a dislocated hip is relatively easy because the clinical situation is very typical. Having identified a dislocated hip, the first step is to perform a closed reduction of the implant. After reduction you must perform a computed tomography scan to evaluate the surgical options for treatment of recurrent dislocation that include: revision arthroplasty, modular components exchange, dual-mobility cups, large femoral heads, constrained cups, elimination of impingement and soft tissue procedures. The objective is to avoid further dislocation, a devastating event which is increasing the number of operations on the hip. To obtain this goal is useful to follow an algorithm of treatment, but the best treatment remains prevention.
Collapse
Affiliation(s)
- Francesco Falez
- Orthopaedic and Traumatology Department, S. Spirito Hospital, Lungotevere in Sassia,1, Rome, Italy.
| | - Matteo Papalia
- Orthopaedic and Traumatology Department, Nuova Itor Clinic, Rome, Italy
| | - Fabio Favetti
- Orthopaedic and Traumatology Department, S. Spirito Hospital, Lungotevere in Sassia,1, Rome, Italy
| | - Gabriele Panegrossi
- Orthopaedic and Traumatology Department, S. Spirito Hospital, Lungotevere in Sassia,1, Rome, Italy
| | - Filippo Casella
- Orthopaedic and Traumatology Department, S. Spirito Hospital, Lungotevere in Sassia,1, Rome, Italy
| | - Gianluca Mazzotta
- Orthopaedic and Traumatology Department, S. Spirito Hospital, Lungotevere in Sassia,1, Rome, Italy
| |
Collapse
|
16
|
Wear of dual-mobility cups: a review article. INTERNATIONAL ORTHOPAEDICS 2016; 41:625-633. [DOI: 10.1007/s00264-016-3326-9] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2016] [Accepted: 10/17/2016] [Indexed: 12/26/2022]
|
17
|
Chalmers BP, Arsoy D, Sierra RJ, Lewallen DG, Trousdale RT. High Failure Rate of Modular Exchange With a Specific Design of a Constrained Liner in High-Risk Patients Undergoing Revision Total Hip Arthroplasty. J Arthroplasty 2016; 31:1963-9. [PMID: 26975601 DOI: 10.1016/j.arth.2016.02.021] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2015] [Revised: 02/01/2016] [Accepted: 02/09/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Addressing recurrent instability in patients with poor bone stock and inadequate abductor tensioning remains a challenge in revision total hip arthroplasty. One treatment method is implantation of a constrained liner. The purpose of this study was to determine clinical outcomes, redislocation rate, and revisions of a focally constrained liner in a high-risk patient cohort. METHODS Fifty-eight hips between 2008 and 2011 underwent implantation of a focally constrained liner. Nineteen were placed concurrent with acetabular component revision and 39 were placed into a well-fixed acetabular shell. Mean age was 69 years and mean number of previous ipsilateral hip surgeries was 4.2. At mean follow-up of 3.5 years, we analyzed clinical outcomes, redislocation, and revisions. RESULTS Mean Harris Hip Scores was 74. Fourteen hips (24%) were revised and 3 hips (5%) required reoperation at final follow-up. Eleven hips (19%) redislocated at a mean time to dislocation of 12.2 months; 31% (11 of 36 patients) that underwent modular exchange specifically for instability redislocated. Risk factors for redislocation included number of previous surgeries (P = .013), implantation of a 28 mm femoral head (hazards ratio 12.8), revision indication of instability (P = .04), and modular exchange with constrained liner implantation without acetabular shell revision (P = .01). CONCLUSION Implantation of a focally constrained liner in revision total hip arthroplasty for recurrent instability has a high failure rate, especially with a modular exchange. Although concurrent acetabular revision had a lower redislocation rate, the decision to revise a well-fixed cup should be weighed with potential complications associated with cup revision.
Collapse
Affiliation(s)
- Brian P Chalmers
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Diren Arsoy
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Rafael J Sierra
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - David G Lewallen
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | | |
Collapse
|
18
|
Yassin M, Garti A, Khatib M, Weisbrot M, Robinson D. Retentive Cup Arthroplasty in Selected Hip Fracture Patients-A Prospective Series With a Minimum 3-Year Follow-Up. Geriatr Orthop Surg Rehabil 2016; 7:178-182. [PMID: 27847676 PMCID: PMC5098687 DOI: 10.1177/2151458516661384] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Objective: To evaluate the efficacy of the use of retentive cup primary total hip replacement (THR) in high-dislocation risk subcapital fracture patients. Methods: During the years 2008 to 2012, 354 patients with displaced subcapital fracture were operated at our institute. The patients were selected to undergo primary constrained THR according to the following criteria: (1) a preinjury grade 4 or more on the Functional Independence Measure mobility item “5. Locomotion: walking/wheelchair” and grade 4 is defined as “4. Minimal assistance Requiring incidental hands-on help only” (patient performs >75% of the task) and (2) a disease leading to poor motor control. Exclusion criteria were normal muscular control and known infection of the involved joint. Results: Of the 354 patients, 87 fulfilled the inclusion criteria and underwent constrained total hip. Average age was 78 years with a female predominance (73%). Fifteen patients had prior hemiparesis, 19 had Parkinson disease, and 35 had generalized sarcopenia. Eighty-five patients had an uneventful recovery, with an average Hip Disability and Osteoarthritis Outcome Score (HOOS) of 76 ± 7 at 2 years. In 2 patients, the prostheses dislocated. In both cases, the dislocation was due to ring displacement and the inner head dislocated. One case was infected and the patient was treated by a Girdlestone procedure. In the other case, the prosthetic head was revised. The patient remained asymptomatic and at 4-year follow-up had an HOOS of 85. Discussion: It appears that constrained prosthesis is a suitable treatment for patients with poor muscular control having subcapital fractures. The functional results appear to be superior to those of bipolar arthroplasty and similar to the results of primary total hip arthroplasty while the dislocation risk is <3%. Conclusion: Semielective total hip arthroplasty using a retentive cup liner appears to offer good functional results with a low dislocation rate in patients with poor muscular control.
Collapse
Affiliation(s)
- Mustafa Yassin
- Department of Orthopedic Surgery, Rabin Medical Center, Hasharon Hospital, Tel Aviv University Medical School, Petah Tikva, Israel
| | - Avraham Garti
- Department of Orthopedic Surgery, Rabin Medical Center, Hasharon Hospital, Tel Aviv University Medical School, Petah Tikva, Israel
| | - Muhammad Khatib
- Department of Orthopedic Surgery, Rabin Medical Center, Hasharon Hospital, Tel Aviv University Medical School, Petah Tikva, Israel
| | - Moshe Weisbrot
- Department of Orthopedic Surgery, Rabin Medical Center, Hasharon Hospital, Tel Aviv University Medical School, Petah Tikva, Israel
| | - Dror Robinson
- Department of Orthopedic Surgery, Rabin Medical Center, Hasharon Hospital, Tel Aviv University Medical School, Petah Tikva, Israel
| |
Collapse
|
19
|
Abstract
There is no published literature to support mid to long term results of hip resurfacing (HR) arthroplasty in patients over the age of 70 years. The purpose of our study was to evaluate the function HR in this age group (70 or older at the time of surgery) at medium to long term follow-up. Between July 1997 and November 2002, the Oswestry Outcome Centre independently and prospectively collected data on 5000 Birmingham Hip Resurfacings (BHRs). 106 had been implanted in elderly patients who were 70 years of age or older. The post-operative Harris and Merle D'Aubigné and Postel (MDP) hip scores and causes for revision were used to ascertain function and implant survival. Hip scores for the older BHR patients were compared with those from younger patients. The average age at surgery of the elderly BHR cohort was 73.2 years (range, 70.0 to 87.9 years) with a mean follow-up of 7.1 years (range, 0.5 to 10.9 years). Four patients had a femoral neck fracture and required conversion to a conventional total hip replacement. There were no patients lost to follow-up and no dislocations in this series. The median Harris hip score (HHS) was significantly better in the younger BHR group compared with the elderly BHR group, (96 vs. 94 p=0.008). There was no significant difference in recovery rates after surgery. There was a significantly higher rate of revision in women than men among the elderly patients (male= 1 of 65 (1.5%); women = 3 of 19 (15.8%), p=0.03). At latest follow-up the elderly patients continued to function well when compared with the younger BHR patients. There was a high mid to long term success rate after HR in patients who were 70 years of age or older, without the failure burden possibly anticipated. Elderly patients had a poorer functional outcome, but a difference in HHS of two points may be of only minor clinical significance.
Collapse
|
20
|
Yoshimoto K, Nakashima Y, Aota S, Kaneuji A, Fukui K, Hirakawa K, Nakura N, Kinoshita K, Naito M, Iwamoto Y. Re-dislocation after revision total hip arthroplasty for recurrent dislocation: a multicentre study. INTERNATIONAL ORTHOPAEDICS 2016; 41:253-258. [PMID: 26893219 DOI: 10.1007/s00264-016-3127-1] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/25/2015] [Accepted: 02/08/2016] [Indexed: 11/26/2022]
Abstract
PURPOSE Although most case of dislocations after total hip arthroplasty (THA) can be managed with conservative treatment, recurrent dislocation may require surgical intervention. This multicentre study was conducted to evaluate the re-dislocation rate after revision THA for recurrent dislocation, and to determine the risk factors for re-dislocation. METHODS We retrospectively reviewed the 88 hips in 88 patients who underwent revision THA for recurrent dislocation at five institutions between 1995 and 2014. The mean patient age at surgery was 68.5 years and the mean follow-up period was 53.1 months. Multivariate logistic regression was performed to identify risk factors for re-dislocation. RESULTS Sixteen hips in 16 patients (18.2 %) re-dislocated at a mean of 25.5 months (range, 1-83 months) after revision THA. Multivariate analysis identified osteonecrosis of the femoral head (odds ratio [OR] = 5.62 vs. osteoarthritis) and a femoral head size < 32 mm (OR = 3.86) as independent risk factors for re-dislocation. Eight hips required additional revision THA for re-dislocation. CONCLUSION The re-dislocation rate after revision THA for recurrent dislocation remains high, suggesting the need for prevention measures. We recommend the use of a femoral head size ≥ 32 mm.
Collapse
Affiliation(s)
- Kensei Yoshimoto
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| | - Yasuharu Nakashima
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
| | - Shigeo Aota
- Department of Orthopaedics, Fukushima Medical University, 1 Hikarigaoka, Fukushima, 960-1295, Japan
| | - Ayumi Kaneuji
- Department of Orthopaedic Surgery, Kanazawa Medical University, 1-1 Daigaku, Uchinada-machi, Kahokugun, Ishikawa, 920-0293, Japan
| | - Kiyokazu Fukui
- Department of Orthopaedic Surgery, Kanazawa Medical University, 1-1 Daigaku, Uchinada-machi, Kahokugun, Ishikawa, 920-0293, Japan
| | - Kazuo Hirakawa
- Shonan Kamakura Joint Reconstruction Center, 5-4-17 Dai, Kamakura, Kanagawa, 247-0061, Japan
| | - Nariaki Nakura
- Shonan Kamakura Joint Reconstruction Center, 5-4-17 Dai, Kamakura, Kanagawa, 247-0061, Japan
| | - Koichi Kinoshita
- Department of Orthopaedic Surgery, Fukuoka University School of Medicine, 7-45-1 Nanakuma, Jonan-ku, Fukuoka, 814-0133, Japan
| | - Masatoshi Naito
- Department of Orthopaedic Surgery, Fukuoka University School of Medicine, 7-45-1 Nanakuma, Jonan-ku, Fukuoka, 814-0133, Japan
| | - Yukihide Iwamoto
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| |
Collapse
|
21
|
Zajonz D, Philipp H, Schleifenbaum S, Möbius R, Hammer N, Grunert R, Prietzel T. [Larger heads compensate for an increased risk of THA dislocation in high-risk patients]. DER ORTHOPADE 2016; 44:381-91. [PMID: 25869176 DOI: 10.1007/s00132-015-3093-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND Dislocation is a devastating complication after total hip arthroplasty (THA) and occurs in 2-5% of primary THA cases and 5-10% of revision THA cases. Assuming correct implantation, dislocation risk can be reduced primarily by capsular repair and the use of larger prosthetic heads. However, larger heads are also associated with risks like accelerated wear or implant loosening, which is why heads with a maximum diameter of 36 mm are currently standard in primary THA. In cases with high dislocation risk, the use of 40 mm and 44 mm heads should be considered. OBJECTIVES This study aimed to quantify THA dislocation risk and retrospectively analyze the course of disease in high-risk patients treated with 40 mm or 44 mm femoral heads after primary or revision THA, concerning dislocation and other complications suffered. MATERIALS AND METHODS All patients with increased THA dislocation risk, treated from 2009-2014, were evaluated regarding dislocations. The cases with installation of 40 mm or 44 mm prosthetic heads were classified using a self-developed 5-level risk score and retrospectively analyzed. RESULTS During the observation period, 288 THA interventions with increased dislocation risk were performed. In 278 cases with ball diameters ≤ 36 mm the dislocation rate was 15.1% (n=42). In 10 high dislocation-risk cases (3A to 4B according to recommended scoring system), 40 mm and 44 mm heads were used. After a 22.8 month mean follow-up, no THA dislocations were reported. CONCLUSION Our results with 40 and 44 mm heads and the existing literature confirm much higher joint stability and, thus, significantly reduced dislocation risk with larger prosthetic heads in THA. Their use is, therefore, justified in high-risk patients and should be considered in future THA.
Collapse
Affiliation(s)
- D Zajonz
- Klinik und Poliklinik für Orthopädie, Unfallchirurgie und Plastische Chirurgie, Universitätsklinikum Leipzig, Liebigstr. 20, 04103, Leipzig, Deutschland
| | | | | | | | | | | | | |
Collapse
|
22
|
Cip J, Bach C, Widemschek M, Luegmair M, Martin A. Revision of Articular Surface Replacement (ASR) Total Hip Arthroplasty: Correlation of Perioperative Data and Early Post-Revision Outcome Results. J Arthroplasty 2015; 30:1607-17. [PMID: 25956526 DOI: 10.1016/j.arth.2015.04.010] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2014] [Revised: 03/24/2015] [Accepted: 04/06/2015] [Indexed: 02/01/2023] Open
Abstract
The articular surface replacement (ASR) total hip arthroplasty (THA) showed accelerated failure rates due to adverse-reaction to metal debris (ARMD). Literature correlating preoperative with intraoperative revision findings respectively post-revision outcome results are rare. 30 of 99 available ASR THA were revised due to ARMD. Mean post-revision follow-up term was 2.3 years. In part, preoperative data did not correlate with intraoperative revision findings. ARMD was even found in asymptomatic patients with non-elevated ion levels. Postoperative pain and metal ions decreased significantly (P ≤ 0.016). Cobalt decreased faster than chrome. Patients with intraoperative pseudotumors, osteolysis or bilateral THA did not have higher pre- or postoperative ion values (P ≥ 0.053). Females showed higher postoperative chrome levels (P=0.031). One major post-revision complication (femoral nerve palsy) and one re-revision (late onset infection) occurred.
Collapse
Affiliation(s)
- Johannes Cip
- Department of Orthopedic Surgery, Academic Teaching Hospital Feldkirch, Medical University of Innsbruck, Feldkirch, Austria
| | - Christian Bach
- Department of Orthopedic Surgery, Academic Teaching Hospital Feldkirch, Medical University of Innsbruck, Feldkirch, Austria
| | - Mark Widemschek
- Department of Orthopedic Surgery, Academic Teaching Hospital Feldkirch, Medical University of Innsbruck, Feldkirch, Austria
| | - Matthias Luegmair
- Department of Orthopedic Surgery, Academic Teaching Hospital Feldkirch, Medical University of Innsbruck, Feldkirch, Austria
| | - Arno Martin
- Department of Orthopedic Surgery, Academic Teaching Hospital Feldkirch, Medical University of Innsbruck, Feldkirch, Austria
| |
Collapse
|
23
|
Murtha AS, Roy ME, Whiteside LA, Tilden DS, Schmitt KL. Thin-Walled Cross-Linked Acetabular Liners Need Not Exhibit Reduced Locking Strength. Orthopedics 2015; 38:e727-32. [PMID: 26270761 DOI: 10.3928/01477447-20150804-62] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2014] [Accepted: 11/24/2014] [Indexed: 02/03/2023]
Abstract
Use of larger diameter femoral heads has emerged as a promising strategy to reduce the risk of dislocation after total hip arthroplasty, but thinning the walls of cross-linked ultra-high-molecular-weight polyethylene (UHMWPE) acetabular liners to accommodate these larger heads may compromise the locking mechanism of the liner. The purpose of this study was to test the mechanical integrity of the locking mechanism in cross-linked and re-melted UHMWPE acetabular components with reduced wall thickness. The locking mechanism of cross-linked (100 kGy/re-melted) acetabular liners in sizes 50/28, 50/36, and 52/36 mm of 1 design was evaluated by lever-out tests and torsion tests. Torsion tests were performed at 2 angles to isolate the liner's locking tabs independent of the contribution of its central post. Lever-out testing demonstrated nominally reduced failure strength in 50/36-mm liners (13.3 N · m) compared with 50/28-mm liners (12.3 N · m; P=.0502), whereas the lever-out strength of 52/36-mm liners was 12.2±0.94 N · m. Failure torques were similar between 50/28- and 50/36-mm liners at 45° and 90°, but the failure torque of size 52/36-mm liners was significantly higher at each angle. The use of larger diameter femoral heads does not compromise the locking mechanism of thinned MicroSeal (Signal Medical Corp, Marysville, Michigan) acetabular liners. Use of a cross-linked UHMWPE acetabular liner, with a locking mechanism that is not compromised when the liner is thinned to a thickness of at least 2.86 mm, appears to be a biomechanically sound construct when articulated with large diameter femoral heads.
Collapse
|
24
|
The Cumulative Risk of Re-dislocation After Revision THA Performed for Instability Increases Close to 35% at 15years. J Arthroplasty 2015; 30:1177-82. [PMID: 25686783 DOI: 10.1016/j.arth.2015.02.001] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/19/2014] [Revised: 01/30/2015] [Accepted: 02/03/2015] [Indexed: 02/01/2023] Open
Abstract
A retrospective analysis was conducted on 539 hips undergoing revision total hip arthroplasty done for instability to report the cumulative risk and factors associated with re-dislocation and re-revision. The cumulative risk of re-dislocation and re-revision for all cause was 34.5% and 45.9% at 15 years, respectively. Multiple variable analyses revealed history of 2 or more previous surgeries, use of head size less than 36 mm, and cup retention to be risk factors for re-dislocation and re-revision. The use of a constrained liner was protective against re-dislocation but was not associated with a lower re-revision rate. Understanding the risk factors associated with re-dislocation or re-revision may help with perioperative decision making in order to decrease the high failure rate seen in this study.
Collapse
|
25
|
Jassim SS, Patel S, Wardle N, Tahmassebi J, Middleton R, Shardlow DL, Stephen A, Hutchinson J, Haddad FS. Five-year comparison of wear using oxidised zirconium and cobalt–chrome femoral heads in total hip arthroplasty. Bone Joint J 2015; 97-B:883-9. [DOI: 10.1302/0301-620x.97b7.35285] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Oxidised zirconium (OxZi) has been developed as an alternative bearing surface for femoral heads in total hip arthroplasty (THA). This study has investigated polyethylene wear, functional outcomes and complications, comparing OxZi and cobalt–chrome (CoCr) as part of a three-arm, multicentre randomised controlled trial. Patients undergoing THA from four institutions were prospectively randomised into three groups. Group A received a CoCr femoral head and highly cross-linked polyethylene (XLPE) liner; Group B received an OxZi femoral head and XLPE liner; Group C received an OxZi femoral head and ultra-high molecular weight polyethylene (UHMWPE) liner. At five years, 368 patients had no statistically significant differences in short-form-36 (p = 0.176 mental, p = 0.756 physical), Western Ontario and McMaster Universities Osteoarthritis Index (p = 0.847), pain scores (p = 0.458) or complications. The mean rate of linear wear was 0.028 mm/year (standard deviation (sd) 0.010) for Group A, 0.023 mm/year (sd 0.010) for Group B, and 0.09 mm/year (sd 0.045) for Group C. Penetration was significantly higher in the UHMWPE liner group compared with both XLPE liner groups (p < 0.001) but no significant difference was noted between CoCr and OxZi when articulating with XLPE (p = 0.153). In this, the largest randomised study of this bearing surface, it appears that using a XLPE acetabular liner is more important in reducing THA component wear than the choice of femoral head bearing, at mid-term follow-up. There is a non-significant trend towards lower wear, coupling OxZi rather than CoCr with XLPE but long-term analysis is required to see if this observation changes with time and becomes significant. Cite this article: Bone Joint J 2015;97-B:883–9.
Collapse
Affiliation(s)
- S. S. Jassim
- Royal National Orthopaedic Hospital, Brockley
Hill, Stanmore HA7 4LP, UK
| | - S. Patel
- University College London Hospitals, 235
Euston Road, London NW1 2BU, UK
| | - N. Wardle
- Colchester Hospital University Foundation
Trust, Turner Road, Colchester
CO4 5JL, UK
| | - J. Tahmassebi
- Trauma and Orthopaedics , Ground
Floor Central, 250 Euston Road, London
NW1 2PG, UK
| | | | - D. L. Shardlow
- Yeovil District Hospital NHSFT, Higher
Kingston, Yeovil BA21 4AT, UK
| | - A. Stephen
- Royal Derby Hospital, Uttoxeter
New Road, Derby DE22 3NE, UK
| | - J. Hutchinson
- Royal Derby Hospital, Uttoxeter
New Road, Derby DE22 3NE, UK
| | - F. S. Haddad
- University College London Hospitals, 235
Euston Road, London NW1 2BU, UK
| |
Collapse
|
26
|
Risk factors for total hip arthroplasty dislocation and its functional outcomes. Rev Esp Cir Ortop Traumatol (Engl Ed) 2015. [DOI: 10.1016/j.recote.2014.11.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
27
|
Implication of femoral stem on performance of articular surface replacement (ASR) XL total hip arthroplasty. J Arthroplasty 2014; 29:2127-35. [PMID: 25108735 DOI: 10.1016/j.arth.2014.06.025] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/13/2014] [Revised: 06/14/2014] [Accepted: 06/29/2014] [Indexed: 02/01/2023] Open
Abstract
Taper junctions of large diameter metal-on-metal femoral heads and femoral stems were described as metal ion generator due to accelerated wear and corrosion. However, literature about the Articular Surface Replacement (ASR) total hip arthroplasty (THA) invariably deals with stems manufactured by DePuy Orthopedics (Warsaw, IN, USA). Nothing is known whether different stems with common 12/14 mm tapers affect failure rate or ion release. 99 ASR THA (88 patients) implanted with CoxaFit or ARGE Geradschaft stems (K-Implant, Hannover, Germany) were retrospectively analyzed. After a mean follow-up of 3.5 years revision rate was 24.5%, mostly due to adverse reaction to metal debris (ARMD). CT scan revealed component loosening in 10.3% and pseudotumoral lesions in 12.6%. Elevated ion concentrations (>7 μg/l) were found in 38.6%.
Collapse
|
28
|
Cementless dual-mobility cup in total hip arthroplasty revision. INTERNATIONAL ORTHOPAEDICS 2014; 38:2463-8. [PMID: 25078366 DOI: 10.1007/s00264-014-2448-1] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2014] [Accepted: 06/23/2014] [Indexed: 10/25/2022]
Abstract
PURPOSE Dislocation is a frequent complication in total hip arthroplasty (THA) revision. Cup fixation is the second concern. In order to know outcomes at two years, we prospectively followed a continuous series of 78 patients to demonstrate that cementless dual-mobility cup (DMC) used in revision THA is safe as regards dislocation risk and bone fixation. METHOD We enrolled 78 consecutive patients (79 cases) in a prospective study. Mean interval between index surgery and revision was 12.9 years. Mean age at revision was 75.5 years. Two types of cementless DMC were used: a standard DMC in 68 cases with low-grade bone defect (Paprosky grade 1 and 2), and a specific design reconstruction DMC in 11 cases with severe bone loss (Paprosky grade 3). RESULTS At two years of follow-up, 68 patients were reviewed; four were lost to follow-up., and six patients were deceased. We identified three types of situations at risk:standard risk (33 cases), Paprosky grade 1 or 2; medium risk (37 cases), revision for recurrent instability (21), periprosthetic fractures (14) or severe loosening Paprosky grade 3 without femorotomy (2); high risk (nine cases), revision for severe loosening with a femorotomy. One (1.3%) patient dislocated her hip at one month without recurrence. Revision rate for dislocation was 0%; two (2.7%) early mechanical failures occurred. CONCLUSION Considering outcomes of this series, cementless DMC can be suggested in THA revision surgery.
Collapse
|
29
|
[Risk factors for total hip arthroplasty dislocation and its functional outcomes]. Rev Esp Cir Ortop Traumatol (Engl Ed) 2014; 59:19-25. [PMID: 25048273 DOI: 10.1016/j.recot.2014.05.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2013] [Revised: 07/29/2013] [Accepted: 05/29/2014] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVES To evaluate risk factors for dislocation after primary total hip arthroplasty (THA), and its functional outcomes. MATERIAL AND METHODS A retrospective study was conducted on 22 cases with dislocation and 431 controls without dislocation, all performed with lateral access. The data were collected prospectively with a minimum follow-up of 5 years. Patient related factors, from primary surgery, and position of components on simple radiographs were analyzed. Harris and Merle D'Aubigné hip scores, and short Womac questionnaire were used. RESULTS Demographic, patient-related or surgical technique factors were not risk predictors of dislocation. With regard to position of components, an acetabular abduction >50° (p = 0.003) and anteversion lower or higher than 10°- 20° (p = 0.044) were risk factors. Controls and dislocation treated conservatively had similar outcomes, and in both were better than in those treated with surgical revision (p = 0.03). DISCUSSION Factors relating to the patient and soft tissues status may influence the stability of the arthroplasty, but malposition of the acetabular component seems to be the most important and common risk factor for dislocation.
Collapse
|
30
|
Prietzel T, Hammer N, Schleifenbaum S, Kaßebaum E, Farag M, von Salis-Soglio G. On the permanent hip-stabilizing effect of atmospheric pressure. J Biomech 2014; 47:2660-5. [PMID: 24938930 DOI: 10.1016/j.jbiomech.2014.05.013] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2013] [Revised: 05/13/2014] [Accepted: 05/17/2014] [Indexed: 11/16/2022]
Abstract
Hip joint dislocations related to total hip arthroplasty (THA) are a common complication especially in the early postoperative course. The surgical approach, the alignment of the prosthetic components, the range of motion and the muscle tone are known factors influencing the risk of dislocation. A further factor that is discussed until today is atmospheric pressure which is not taken into account in the present THA concepts. The aim of this study was to investigate the impact of atmospheric pressure on hip joint stability. Five joint models (Ø 28-44 mm), consisting of THA components were hermetically sealed with a rubber capsule, filled with a defined amount of fluid and exposed to varying ambient pressure. Displacement and pressure sensors were used to record the extent of dislocation related to intraarticular and ambient pressure. In 200 experiments spontaneous dislocations of the different sized joint models were reliably observed once the ambient pressure was lower than 6.0 kPa. Increasing the ambient pressure above 6.0 kPa immediately and persistently reduced the joint models until the ambient pressure was lowered again. Displacement always exceeded half the diameter of the joint model and was independent of gravity effects. This experimental study gives strong evidence that the hip joint is permanently stabilized by atmospheric pressure, confirming the theories of Weber and Weber (1836). On basis of these findings the use of larger prosthetic heads, capsular repair and the deployment of an intracapsular Redon drain are proposed to substantially decrease the risk of dislocation after THA.
Collapse
Affiliation(s)
- Torsten Prietzel
- Department of Orthopedic Surgery, University of Leipzig, Liebigstraße 20, D-04103 Leipzig, Germany.
| | - Niels Hammer
- Institute of Anatomy, University of Leipzig, Liebigstraße 13, D-04103 Leipzig, Germany.
| | - Stefan Schleifenbaum
- Department of Orthopedic Surgery, University of Leipzig, Liebigstraße 20, D-04103 Leipzig, Germany.
| | - Eric Kaßebaum
- Lausitz University of Applied Sciences, Großenhainer Straße 57, D-01968 Senftenberg, Germany.
| | - Mohamed Farag
- Department of Spinal Surgery, Clinical Centre Bad Berka, Robert-Koch-Allee 9, D-99437 Bad Berka, Germany; Department of Orthopedic Surgery, University of Leipzig, Liebigstraße 20, D-04103 Leipzig, Germany.
| | - Georg von Salis-Soglio
- Department of Orthopedic Surgery, University of Leipzig, Liebigstraße 20, D-04103 Leipzig, Germany.
| |
Collapse
|
31
|
Karampinas PK, Evangelopoulos DS, Vlamis J, Nikolopoulos K, Korres DS. Confronting hip resurfacing and big femoral head replacement gait analysis. Orthop Rev (Pavia) 2014; 6:5221. [PMID: 24744841 PMCID: PMC3980157 DOI: 10.4081/or.2014.5221] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2013] [Accepted: 02/10/2014] [Indexed: 11/23/2022] Open
Abstract
Improved hip kinematics and bone preservation have been reported after resurfacing total hip replacement (THRS). On the other hand, hip kinematics with standard total hip replacement (THR) is optimized with large diameter femoral heads (BFH-THR). The purpose of this study is to evaluate the functional outcomes of THRS and BFH-THR and correlate these results to bone preservation or the large femoral heads. Thirty-one patients were included in the study. Gait speed, postural balance, proprioception and overall performance. Our results demonstrated a non-statistically significant improvement in gait, postural balance and proprioception in the THRS confronting to BFH-THR group. THRS provide identical outcomes to traditional BFH-THR. The THRS choice as bone preserving procedure in younger patients is still to be evaluated.
Collapse
Affiliation(s)
- Panagiotis K Karampinas
- Third Department of Orthopaedic Surgery, University of Athens, KAT Hospital , Athens, Greece
| | | | - John Vlamis
- Third Department of Orthopaedic Surgery, University of Athens, KAT Hospital , Athens, Greece
| | | | - Dimitrios S Korres
- Third Department of Orthopaedic Surgery, University of Athens, KAT Hospital , Athens, Greece
| |
Collapse
|
32
|
Charissoux JL, Asloum Y, Marcheix PS. Surgical management of recurrent dislocation after total hip arthroplasty. Orthop Traumatol Surg Res 2014; 100:S25-34. [PMID: 24434366 DOI: 10.1016/j.otsr.2013.11.008] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2013] [Revised: 06/18/2013] [Accepted: 11/06/2013] [Indexed: 02/02/2023]
Abstract
Dislocation is a major complication of total hip arthroplasty (THA), whose frequency has been unaffected by improvements in surgical techniques and implants. The dislocation rate depends on multiple factors related to the patient, hip disease, and surgical procedure and is therefore also dependent on the surgeon. The many published studies on THA dislocation, its causes, and its treatment have produced conflicting results. The objective of this work is to review the management of THA dislocation, which is a severe event for both the patient and the surgeon. This lecture starts with a brief review of data on THA dislocation rates and the many factors that influence them. Emphasis is then put on the evaluation for a cause and, more specifically, on the challenges raised by detecting suboptimal cup position. Next, reported techniques for treating THA dislocation and the outcomes of each are discussed. Finally, a management strategy for patients selected for revision surgery is suggested.
Collapse
Affiliation(s)
- J-L Charissoux
- Service d'orthopedie traumatologie, CHU Dupuytren, 2, avenue Martin-Luther-King, 87042 Limoges cedex, France.
| | - Y Asloum
- Service d'orthopedie traumatologie, CHU Dupuytren, 2, avenue Martin-Luther-King, 87042 Limoges cedex, France
| | - P-S Marcheix
- Service d'orthopedie traumatologie, CHU Dupuytren, 2, avenue Martin-Luther-King, 87042 Limoges cedex, France
| |
Collapse
|
33
|
Agarwala S, Mohrir G, Moonot P. Functional outcome following a large head total hip arthroplasty: A retrospective analysis of mid term results. Indian J Orthop 2014; 48:410-4. [PMID: 25143647 PMCID: PMC4137521 DOI: 10.4103/0019-5413.136295] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND One of the reasons that hip resurfacing and large head metal on metal (MOM) total hip arthroplasty (THA) became popular in Asia was the possible increased range of movement and thereby improved function of the hip joint. Due to concerns of MOM articulation an alternative bearing was sought. Hence, a shift from large head MOM to large head ceramic on ceramic (COC) was made. The aim of this study was to compare the functional outcome including range of motion (ROM) and dislocation rates following large head MOM and large head COC THA. MATERIALS AND METHODS Retrospectively, 39 primary THA with large head MOM with a mean age of 56 years (range 36-72 years) and average followup of 54 months (range 38-70 months) were compared with 23 primary THA with large head COC bearing with a mean age of 48 years (range 36-68 years) and an average followup of 18 months (range 12-26 months). Functional outcome was assessed using the Modified Harris Hip Score. Dislocation rate and ROM were compared. RESULTS Global ROM averaged 248 degrees with MOM group and 252 degrees with the COC group. One patient with metal bearing had dislocation at an average 3 year followup which required revision THA while there were no complications in the COC group. MHHS averaged 89 points in MOM and 94 in COC THR. CONCLUSION This study has shown that large head ceramic on ceramic THA is a good alternative to large head metal on metal THA with comparable dislocation rates and range of movements and without complications of metallosis in Asian patients.
Collapse
Affiliation(s)
- Sanjay Agarwala
- Department of Orthopedics, P.D. Hinduja National Hospital and MRC, Mumbai, India,Address for correspondence: Dr. Sanjay Agarwala, Department of orthopedics, P.D. Hinduja National Hospital and MRC, Veer Savarkar Marg, Mahim (W), Mumbai - 400 016, Maharashtra, India. E-mail:
| | - Ganesh Mohrir
- Department of Orthopedics, P.D. Hinduja National Hospital and MRC, Mumbai, India
| | - Pradeep Moonot
- Department of Orthopedics, P.D. Hinduja National Hospital and MRC, Mumbai, India
| |
Collapse
|
34
|
Munro JT, Vioreanu MH, Masri BA, Duncan CP. Acetabular liner with focal constraint to prevent dislocation after THA. Clin Orthop Relat Res 2013; 471:3883-90. [PMID: 23423623 PMCID: PMC3825877 DOI: 10.1007/s11999-013-2858-1] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Dislocation continues to commonly cause failure after primary and revision total hip arthroplasty (THA). Fully constrained liners intended to prevent dislocation are nonetheless associated with a substantial incidence of failure by redislocation, mechanical failure, aseptic loosening, or a combination. Constrained liners with cutouts of the elevated rims can theoretically increase range of movement and therefore decrease the risk dislocation, but it is unclear if they do so in practice and whether they are associated with early wear or loosening. QUESTIONS/PURPOSES We therefore determined (1) occurrence or recurrence of dislocation and (2) rate of complications associated with constrained implants with cutouts; and (3) assessed for early cup loosening. METHODS We retrospectively reviewed the records of 81 patients at high risk for dislocation who had 82 constrained liners inserted for primary (n = 10) or revision (n = 72) THA between 2008 and 2010. From the records we extracted demographic and implant data and instances of recurrent dislocation, implant failure, osteolysis, loosening, or construct failure. The minimum followup was 24 months (mean, 34 months; range, 24-49 months). RESULTS Three liners failed as a result of further dislocation (3%). Three deep infections occurred. One patient had progressive loosening at the shell-bone interface. CONCLUSIONS Our observations suggest this liner is associated with a relatively low risk of dislocation in patients at high risk for dislocation and those with recurrent dislocation.
Collapse
Affiliation(s)
- Jacob T. Munro
- Department of Orthopaedics, University of British Columbia, Room 3114, 910 West 10th Avenue, Vancouver, BC V5Z 4E3 Canada
| | - Mihai H. Vioreanu
- Department of Orthopaedics, University of British Columbia, Room 3114, 910 West 10th Avenue, Vancouver, BC V5Z 4E3 Canada
| | - Bassam A. Masri
- Department of Orthopaedics, University of British Columbia, Room 3114, 910 West 10th Avenue, Vancouver, BC V5Z 4E3 Canada
| | - Clive P. Duncan
- Department of Orthopaedics, University of British Columbia, Room 3114, 910 West 10th Avenue, Vancouver, BC V5Z 4E3 Canada
| |
Collapse
|
35
|
Abstract
Dislocation remains one of the most common complications after total hip arthroplasty, regardless of the surgical approach. While multiple reasons as laxity, implant position, improper implant choice, and impingement etc. might be leading factors for dislocation, an exact identification of the exact reason is of major importance, to plan for a proper surgical or nonsurgical correction. This article describes in detail the definition, etiology, reduction, and possible treatment options for dislocation after primary and revision total hip arthroplasty that are currently used at the Endo Klinik in Hamburg. It furthermore includes a distinct overview of possible surgical treatment options, based on the main pathology leading to dislocation.
Collapse
|
36
|
Reproductive toxicity in adult male rats following intra-articular injection of cobalt-chromium nanoparticles. J Orthop Sci 2013; 18:1020-6. [PMID: 24085379 DOI: 10.1007/s00776-013-0458-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2013] [Accepted: 08/12/2013] [Indexed: 02/09/2023]
Abstract
BACKGROUND Recent studies have reported that metallic nanoparticles and ions from cobalt-chromium (CoCr) alloy prostheses had potential adverse effects. However, the biological effects of CoCr nanoparticles on male reproductive function remain unclear. The objective of this study is to investigate the reproductive toxicity in adult male rats following intra-articular injection of cobalt-chromium nanoparticles. METHODS CoCr nanoparticles were generated by a spark discharge method. Adult male rats received intra-articular injections of CoCr nanoparticles once a week at a low (20 μg/kg b.w.), medium (100 μg/kg b.w.) or high dose (500 μg/kg b.w.) for 10 consecutive weeks. The control group received intra-articular injections of physiological saline. After the final injection, all rats were held for a 7-day post-exposure period. The effects on male reproductive function were observed, including the coefficient of testicular to body weight, the epididymal sperm parameters, the concentration of metal ions in serum and testis, the activity of antioxidase and the content of lipid peroxide in the testis, and histopathological examination. RESULTS Compared with the control group, intra-articular injection of high dose CoCr nanoparticles could significantly reduce epididymal sperm motility, viability and concentration, increase abnormal sperm rate and levels of Co and Cr ions in serum and in the testis, and induce testicular damage and pathological changes via oxidative stress. CONCLUSIONS Intra-articular injection of high dose CoCr nanoparticles from MOM articulation may have potential reproductive toxicity in adult male rats.
Collapse
|
37
|
Stroh DA, Issa K, Johnson AJ, Delanois RE, Mont MA. Reduced dislocation rates and excellent functional outcomes with large-diameter femoral heads. J Arthroplasty 2013; 28:1415-20. [PMID: 23602233 DOI: 10.1016/j.arth.2012.11.017] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2012] [Revised: 11/14/2012] [Accepted: 11/26/2012] [Indexed: 02/01/2023] Open
Abstract
The purpose of this study was to compare the dislocation rates, functional outcomes, and radiographic results between large- and small-diameter femoral head components. A total of 225 patients (248-hips) who received total hip arthroplasties with large-diameter components (36mm or greater) were compared to 501 patients (559-hips) who received smaller diameter components (less than 36mm). Rates of dislocation and revision, Harris hip score, radiographic findings, and complications were compared between the groups. At a mean follow-up of approximately 5years, a significantly higher rate of dislocation was noted in the small-diameter group (10 of 559) compared to the large-diameter group (0 of 248). The overall implant survivorship, mean Harris hip scores, complication rates, and radiographic outcomes were similar for the two groups. The authors believe that large-diameter components significantly reduced the risk of dislocation in susceptible patients, while preserving good to excellent functional outcomes.
Collapse
Affiliation(s)
- D Alex Stroh
- Center for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, Maryland 21215, USA
| | | | | | | | | |
Collapse
|
38
|
Johnson AJ, Le Duff MJ, Yoon JP, Al-Hamad M, Amstutz HC. Metal ion levels in total hip arthroplasty versus hip resurfacing. J Arthroplasty 2013; 28:1235-7. [PMID: 23618754 DOI: 10.1016/j.arth.2013.03.015] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2013] [Revised: 03/04/2013] [Accepted: 03/19/2013] [Indexed: 02/01/2023] Open
Abstract
Recent studies suggest that the tapered interface between stem and femoral head may be a substantial source of cobalt and chromium ion release after metal-on-metal (MOM) total hip arthroplasty (THA). This study compared patient ion levels after MOM hip resurfacing (HR) and MOM THA performed with identical acetabular components. 110 HRs were compared with 22 THAs. All had well-oriented components, unilateral implants, and serum ion studies beyond one year post-operatively. The HR group's median cobalt value was 1.11 μg/L vs. 2.86 μg/L for the THA patients. The HR group's median chromium value was 1.49 μg/L vs. 2.94 μg/L for THA. Significantly higher THA ion levels suggest a source of ions other than the MOM bearing itself.
Collapse
Affiliation(s)
- Alicia J Johnson
- Joint Replacement Institute, St Vincent Medical Center, Los Angeles, CA, USA
| | | | | | | | | |
Collapse
|
39
|
The Irish National Joint Registry: where are we now? Ir J Med Sci 2013; 183:77-83. [PMID: 23775278 DOI: 10.1007/s11845-013-0979-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2013] [Accepted: 06/11/2013] [Indexed: 10/26/2022]
Abstract
BACKGROUND Ireland is currently in the process of establishing a National Joint Registry. AIM We aim to determine which implants and surgical techniques are currently being used by Irish orthopaedic surgeons and to examine the impact that a National Joint Registry may have on arthroplasty practice in Ireland. METHODS The study consisted of a postal questionnaire sent to all public service consultant orthopaedic surgeons in The Republic of Ireland. RESULTS We had a response rate of 76.6 %. Of this 76.6, 86.4 % regularly perform total hip arthroplasty (THA) and 84.7 % perform total knee arthroplasty. Of those who perform THA, 86.3 % use different implants in younger patients. Thirteen different femoral implants are used, and seven different knee implants. We conservatively estimate that at least 3,918 total hip arthroplasties and 2,604 total knee arthroplasties are performed in Ireland each year. At present we have no way to precisely monitor the number of arthroplasty procedures being performed, and we have no way of accurately monitoring the short- or long-term outcomes of the many implants used. CONCLUSIONS The establishment of a National Joint Registry for Ireland would benefit the Irish orthopaedic community, and given the large number of procedures being performed, may also be of benefit to the international orthopaedic community.
Collapse
|
40
|
Mukka SS, Mahmood SS, Sjödén GO, Sayed-Noor AS. Dual mobility cups for preventing early hip arthroplasty dislocation in patients at risk: experience in a county hospital. Orthop Rev (Pavia) 2013; 5:48-51. [PMID: 23888200 PMCID: PMC3718234 DOI: 10.4081/or.2013.e10] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2013] [Revised: 04/19/2013] [Accepted: 04/21/2013] [Indexed: 11/25/2022] Open
Abstract
Dislocation remains a major concern after hip arthroplasty. We asked whether dual mobility cups (DMC) would improve early hip stability in patients with high risk of dislocation. We followed 34 patients (21 females, 13 males) treated between 2009 and 2012 with cemented DMC for hip revisions caused recurrent hip prosthetic dislocation or as a primary procedure in patients with high risk of instability. Functional outcome and quality of life were evaluated using Harris Hip Score and EQ-5D respectively. We found that the cemented DMC gave stability in 94%. Seven patients (20%) were re-operated due to infection. One patient sustained a periprosthetic fracture. At follow-up (6 to 36 months, mean 18), the mean Harris hip score was 67 (standard deviation: 14) and mean EQ-5D was 0.76 (standard deviation: 0.12). We concluded that treating patients with high risk of dislocation with DMC can give good stability. However, complications such as postoperative infection can be frequent and should be managed carefully.
Collapse
Affiliation(s)
- Sebastian S Mukka
- Department of Orthopaedics, Sundsvall Teaching Hospital; Department of Surgical and Perioperative Science, Umeå University , Sweden
| | | | | | | |
Collapse
|
41
|
Results of metal-on-metal hip resurfacing in patients 40 years old and younger. Arch Orthop Trauma Surg 2013; 133:267-73. [PMID: 23135156 DOI: 10.1007/s00402-012-1640-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/29/2012] [Indexed: 10/27/2022]
Abstract
The prevalence of total hip arthroplasty in young patients is small but increasing. We analyzed the results of metal-on-metal hip resurfacing (MMHR) in patients aged 40 years or less. In total 74 operations were performed on 64 patients. Mean age at operation was 33.2 years. HHS averaged 92.3 points at latest follow-up, mean UCLA activity was 8.2. Patients with comorbidity evinced lower scores in HHS, in UCLA activity and in quality of life than patients without comorbidities. Eight revisions (10.8 %) were performed, of which seven due to adverse reaction to metal debris. Seven-year survival was 90.5 %. The functional outcome of hip resurfacing in this cohort was excellent, but overall survival was unsatisfactory. Further analysis is required to verify the role of hip resurfacing among young and active patients.
Collapse
|
42
|
Civinini R, Carulli C, Matassi F, Nistri L, Innocenti M. A dual-mobility cup reduces risk of dislocation in isolated acetabular revisions. Clin Orthop Relat Res 2012; 470:3542-8. [PMID: 22700131 PMCID: PMC3492645 DOI: 10.1007/s11999-012-2428-y] [Citation(s) in RCA: 82] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2012] [Accepted: 05/31/2012] [Indexed: 01/31/2023]
Abstract
BACKGROUND Isolated acetabular revisions using standard cups are at risk of dislocation. The introduction of a nonconstrained dual-mobility cup was designed to improve prosthetic stability without increasing loosening rates, but it is unclear whether the risk of dislocation is reduced. QUESTIONS/PURPOSES We therefore determined: (1) if the rate of dislocation in isolated acetabular revisions is lower with a dual-mobility cup, (2) implant survival, (3) patient function, and (4) radiographic incidence of migration, loosening, and osteolysis. METHODS We prospectively followed 33 selected patients who underwent isolated acetabular revisions with a minimum of 2 years' followup (mean, 3 years; range, 2-5 years). In 24 patients a stainless steel dual-mobility cup was cemented into an antiprotrusio cage, whereas in nine we used a hyaluronan dual-mobility revision cup with a foramen hook and superior and posterior flanges screw fixations. We determined Harris hip (HHS) and WOMAC scores and examined radiographs for migration, loosening, and osteolysis. RESULTS There were no dislocations. Survivorship rates of the femoral and acetabular components were 97% at 5 years; the rerevision rate for any reason was 3%. At last followup, the mean HHS increased from 48 points preoperatively to 86 points. No patients had progressive osteolysis, component migration, or loosening on radiographs. CONCLUSION In this select group of isolated acetabular revisions, our data suggest the use of a dual-mobility cup reduced the risk of dislocation without increasing loosening from 2 to 5 years. LEVEL OF EVIDENCE Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Roberto Civinini
- First Orthopaedic Clinic, Department of Special Surgical Science, University of Florence, CTO-Largo Palagi 1, 50139 Florence, Italy
| | - Christian Carulli
- First Orthopaedic Clinic, Department of Special Surgical Science, University of Florence, CTO-Largo Palagi 1, 50139 Florence, Italy
| | - Fabrizio Matassi
- First Orthopaedic Clinic, Department of Special Surgical Science, University of Florence, CTO-Largo Palagi 1, 50139 Florence, Italy
| | - Lorenzo Nistri
- First Orthopaedic Clinic, Department of Special Surgical Science, University of Florence, CTO-Largo Palagi 1, 50139 Florence, Italy
| | - Massimo Innocenti
- First Orthopaedic Clinic, Department of Special Surgical Science, University of Florence, CTO-Largo Palagi 1, 50139 Florence, Italy
| |
Collapse
|
43
|
Abstract
Large femoral heads have been used with increasing frequency over the last decade. The prime reason is likely the effect of large heads on stability. The larger head neck ratio, combined with the increased jump distance of larger heads result in a greater arc of impingement free motion, and greater resistance to dislocation in a provocative position. Multiple studies have demonstrated clear clinical efficacy in diminishing dislocation rates with the use of large femoral heads. With crosslinked polyethylene, wear has been shown to be equivalent between larger and smaller heads. However, the stability advantages of increasing diameter beyond 38 mm have not been clearly demonstrated. More importantly, recent data implicates large heads in the increasing prevalence of groin pain and psoas impingement. There are clear benefits with larger femoral head diameters, but the advantages of diameters beyond 38 mm have not yet been demonstrated clinically.
Collapse
Affiliation(s)
- J. A. Rodriguez
- Center For joint Preservation & Reconstruction, North Shore LIJ/Lenox Hill Hospital, 130 E 77th street, 11th floor, New York, NY-10075, USA
| | - P. A. Rathod
- Center For joint Preservation & Reconstruction, North Shore LIJ/Lenox Hill Hospital, 130 E 77th street, 11th floor, New York, NY-10075, USA
| |
Collapse
|
44
|
Plate JF, Seyler TM, Stroh DA, Issa K, Akbar M, Mont MA. Risk of dislocation using large- vs. small-diameter femoral heads in total hip arthroplasty. BMC Res Notes 2012; 5:553. [PMID: 23039109 PMCID: PMC3508897 DOI: 10.1186/1756-0500-5-553] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2012] [Accepted: 09/20/2012] [Indexed: 11/22/2022] Open
Abstract
Background Dislocation remains a difficult problem in total hip arthroplasty. Large-diameter femoral heads may lower the incidence of dislocation by enhancing the jump distance and decreasing impingement, but their performance against small-diameter heads has not been assessed. This study compared the mid-term radiographic and functional outcomes of two matched cohorts of patients undergoing total hip arthroplasty who had a high pre-operative risk for dislocation and who received either small-diameter (26- or 28-millimeters) or large-diameter (≥36-millimeters) femoral heads. Methods All patients who received large-diameter heads (≥36-millimeter) between 2002 and 2005, and who had pre-operative risk factors for dislocation, were identified in the institution’s joint registry. Forty-one patients (52 hips) who received large-diameter heads were identified, and these patients were matched to 48 patients (52 hips) in the registry who received small-diameter femoral heads. Results At mean final follow-up of 62 months (range, 49 to 101 months), both groups achieved excellent functional outcomes as measured by Harris Hip scores, with slightly better final scores in the large-diameter group (90 vs. 83 points). No patient showed any radiographic signs of loosening. No patient dislocated in the large-diameter femoral head group; the smaller-diameter group had a greater rate of dislocation (3.8%, 2 out of 52). Conclusions Large-diameter femoral head articulations may reduce dislocation rates in patients who have a high pre-operative risk for dislocation while providing the same functional improvements and safety as small-diameter bearings.
Collapse
Affiliation(s)
- Johannes F Plate
- Department of Orthopaedic Surgery, Wake Forest School of Medicine,Medical Center Boulevard, Winston-Salem, NC 27157-1070, USA
| | | | | | | | | | | |
Collapse
|
45
|
Mertl P, Combes A, Leiber-Wackenheim F, Fessy MH, Girard J, Migaud H. Recurrence of dislocation following total hip arthroplasty revision using dual mobility cups was rare in 180 hips followed over 7 years. HSS J 2012; 8:251-6. [PMID: 23144637 PMCID: PMC3470678 DOI: 10.1007/s11420-012-9301-0] [Citation(s) in RCA: 72] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2011] [Accepted: 07/06/2012] [Indexed: 02/06/2023]
Abstract
BACKGROUND Dual mobility (DM) cups of mobile polyethylene were introduced to prevent total hip arthroplasty (THA) dislocation, but no large series with this design to treat recurrent instability have been reported. PURPOSE Our retrospective investigation ascertained the efficiency of DM cups in correction of recurrent dislocation and assessed any adverse effects. METHODS One hundred eighty THAs with recurrent instability were revised to DM cups in 180 patients (mean age, 67.4 ± 11.7 years; range, 19 to 92 years). Thirty-one patients (17.2%) underwent at least one earlier THA revision, and 15 (10.3%) incurred non-union of the greater trochanter. Of the initial group in 2009, 145 patients had completed evaluations which included assessment of the Harris Hip Score and a radiographic assessment at a mean follow-up of 7.7 ± 2.2 years (range, 4 to 14 years). The rate of survival was calculated considering any reason for revision as failure. RESULTS At follow-up, Harris hip score was 83.9 ± 16.1 (range, 21 to 100). Dislocation of the large articulation occurred in seven hips (4.8%), and only two recurred (1.4%) (one requiring additional revision). In addition, two intra-prosthetic dislocations of the small articulation (1.4%) were observed and needed revision surgery. The large number of earlier surgeries and non-union of the greater trochanter were related to recurrent instability. Two cups (1.4%) showed signs of definite loosening; six (4.1%) presented signs of possible loosening. Twenty-nine hips manifested femoral or acetabular osteolysis (20%), but only three were severe. Eight-year survival rate considering revision for any reason was 92.6% (95% CI, 85.5-96.4%). CONCLUSIONS This series indicates that DM cups are a viable option to treat recurrent THA instability. Their design provides a low risk of recurrent instability without increasing mechanical complications.
Collapse
Affiliation(s)
- Patrice Mertl
- Orthopaedics Department, University of Amiens, place Victor-Pauchet, 80054 Amiens, France
| | - Antoine Combes
- Roger Salengro Hospital, Centre Hospitalier Régional Universitaire de Lille, 2 avenue Oscar Lambret, 59037 Lille Cedex, France ,Orthopaedics Department, University of Lille, 2 avenue Oscar Lambret, 59037 Lille Cedex, France
| | | | - Michel Henri Fessy
- Department of Orthopaedics, Traumatology and Sports Medicine, Centre Hospitalier Lyon Sud, chemin du Grand-Revoyet, 69495 Pierre Bénite Cedex, France
| | - Julien Girard
- Roger Salengro Hospital, Centre Hospitalier Régional Universitaire de Lille, 2 avenue Oscar Lambret, 59037 Lille Cedex, France ,Orthopaedics Department, University of Lille, 2 avenue Oscar Lambret, 59037 Lille Cedex, France
| | - Henri Migaud
- Roger Salengro Hospital, Centre Hospitalier Régional Universitaire de Lille, 2 avenue Oscar Lambret, 59037 Lille Cedex, France ,Orthopaedics Department, University of Lille, 2 avenue Oscar Lambret, 59037 Lille Cedex, France
| |
Collapse
|
46
|
Werner BC, Brown TE. Instability after total hip arthroplasty. World J Orthop 2012; 3:122-30. [PMID: 22919568 PMCID: PMC3425631 DOI: 10.5312/wjo.v3.i8.122] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2011] [Revised: 07/01/2012] [Accepted: 08/07/2012] [Indexed: 02/06/2023] Open
Abstract
Instability following total hip arthroplasty (THA) is an unfortunately frequent and serious problem that requires thorough evaluation and preoperative planning before surgical intervention. Prevention through optimal index surgery is of great importance, as the management of an unstable THA is challenging even for an experienced joints surgeon. However, even after well-planned surgery, a significant incidence of recurrent instability still exists. Non-operative management is often successful if the components are well-fixed and correctly positioned in the absence of neurocognitive disorders. If conservative management fails, surgical options include revision of malpositioned components; exchange of modular components such as the femoral head and acetabular liner; bipolar arthroplasty; tripolar arthroplasty; use of a larger femoral head; use of a constrained liner; soft tissue reinforcement and advancement of the greater trochanter.
Collapse
|
47
|
Saragaglia D, Ruatti S, Refaie R. Relevance of a press-fit dual mobility cup to deal with recurrent dislocation of conventional total hip arthroplasty: a 29-case series. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2012; 23:431-6. [DOI: 10.1007/s00590-012-1002-3] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/29/2012] [Accepted: 04/11/2012] [Indexed: 11/29/2022]
|
48
|
Vasukutty NL, Middleton RG, Matthews EC, Young PS, Uzoigwe CE, Minhas THA. The double-mobility acetabular component in revision total hip replacement. ACTA ACUST UNITED AC 2012; 94:603-8. [DOI: 10.1302/0301-620x.94b5.27876] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
We present our experience with a double-mobility acetabular component in 155 consecutive revision total hip replacements in 149 patients undertaken between 2005 and 2009, with particular emphasis on the incidence of further dislocation. The mean age of the patients was 77 years (42 to 89) with 59 males and 90 females. In all, five patients died and seven were lost to follow-up. Indications for revision were aseptic loosening in 113 hips, recurrent instability in 29, peri-prosthetic fracture in 11 and sepsis in two. The mean follow-up was 42 months (18 to 68). Three hips (2%) in three patients dislocated within six weeks of surgery; one of these dislocated again after one year. All three were managed successfully with closed reduction. Two of the three dislocations occurred in patients who had undergone revision for recurrent dislocation. All three were found at revision to have abductor deficiency. There were no dislocations in those revised for either aseptic loosening or sepsis. These results demonstrate a good mid-term outcome for this component. In the 29 patients revised for instability, only two had a further dislocation, both of which were managed by closed reduction.
Collapse
Affiliation(s)
- N. L. Vasukutty
- Pilgrim Hospital, Department
of Trauma and Orthopaedics, Sibsey Road, Boston, Lincolnshire
PE21 9QS, UK
| | - R. G. Middleton
- Cheltenham General Hospital, Department
of Trauma and Orthopaedics, Sandford Road, Cheltenham, Gloucestershire
GL53 7AN, UK
| | - E. C. Matthews
- Pilgrim Hospital, Department
of Trauma and Orthopaedics, Sibsey Road, Boston, Lincolnshire
PE21 9QS, UK
| | - P. S. Young
- Southern General Hospital, Department
of Orthopaedics, 1345 Govan Road, Glasgow G51
4TF, UK
| | - C. E. Uzoigwe
- Leicester Royal Infirmary, Department
of Orthopaedics, Infirmary Square, Leicester LE1
5WW, UK
| | - T. H. A. Minhas
- Pilgrim Hospital, Department
of Trauma and Orthopaedics, Sibsey Road, Boston, Lincolnshire
PE21 9QS, UK
| |
Collapse
|
49
|
Wera GD, Ting NT, Moric M, Paprosky WG, Sporer SM, Della Valle CJ. Classification and management of the unstable total hip arthroplasty. J Arthroplasty 2012; 27:710-5. [PMID: 22036933 DOI: 10.1016/j.arth.2011.09.010] [Citation(s) in RCA: 79] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2011] [Accepted: 09/08/2011] [Indexed: 02/01/2023] Open
Abstract
Seventy-five total hip arthroplasty revisions for instability were classified into 6 primary etiologies: I, acetabular component malposition; II, femoral component malposition; III, abductor deficiency; IV, impingement; V, late wear; or VI, unresolved etiology. The most common etiologies were cup malposition (type I; 33%) and abductor deficiency (type III; 36%). At a mean of 35.3 months, 11 redislocations occurred (14.6%). Acetabular revisions were protective against redislocation (P < .015). The number of previous operations (P = .0379) and previously failed constrained liners (P < .02) were risk factors for failure. Tripolar constrained liners demonstrated improved survivorship vs locking ring types (P < .02); cemented constrained liners failed more often than modular constrained liners (P < .0018). The highest risk of failure was in patients with abductor insufficiency with revisions for other etiologies having a success rate of 90%.
Collapse
Affiliation(s)
- Glenn D Wera
- Department of Orthopaedic Surgery, Case Western Reserve University, Cleveland, Ohio 44116, USA
| | | | | | | | | | | |
Collapse
|
50
|
Abstract
Modular femoral components have been developed to aid in recreating native femoral version, limb length, and offset in total hip arthroplasty. Use of modular implants results in cost savings, as well. Inventory can be reduced while allowing intraoperative flexibility and options. With modular implants, the femoral prosthesis can be built in situ, which is helpful in minimizing incision length and surgical dissection. However, additional modular junctions are associated with increased concern for component failure through taper fretting, fatigue fracture, and local corrosion, which may contribute to elevated serum metal ion levels. The recent trend toward using larger diameter femoral heads may impart higher loads and stress than were seen previously. Although modular components offer a plethora of intraoperative options in primary and revision total hip arthroplasty, the long-term effects of these additional junctions remains unknown.
Collapse
|