Li J, Deng Y, Zhang J, Wang B, Huang K, Liu H, Rong X. Combined effect of artificial cervical disc replacement and facet tropism on the index-level facet joints: a finite element study. BMC Musculoskelet Disord 2024; 25:839. [PMID: 39443893 PMCID: PMC11515681 DOI: 10.1186/s12891-024-07895-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2024] [Accepted: 09/23/2024] [Indexed: 10/25/2024] Open
Abstract
BACKGROUND Artificial Cervical Disc Replacement (ACDR) is an effective treatment for cervical degenerative disc diseases. However, clinical information regarding the facet joint alterations after ACDR was limited. Facet tropism is common in the sub-axial cervical spine. Our previous research indicated that facet tropism could lead to increased pressure on the cervical facet joints. This study aimed to assess the impact of facet tropism on the facet contact force and facet capsule stress after ACDR. METHODS A C2-T1 cervical finite element model was constructed from computed tomography (CT) scans of a 28-year-old male volunteer. Symmetrical, moderate asymmetrical (7 degrees tropism), and severe asymmetrical (14 degrees tropism) models were created at the C5/C6 level by altering the facet orientation at the C5-C6 level. The C5/C6 ACDR was simulated in the intact, moderate asymmetrical and severe asymmetrical models. A 75-N follower load with 1.0-Nm moments was applied to the top of C2 vertebra in the models to simulate flexion, extension, lateral bending, and axial rotation with the T1 vertebra fixed. The range of motions (ROMs) under all moments, facet contact forces (FCFs) and facet capsule strains were tested. RESULTS In the asymmetrical model, the right FCFs considerably increased under flexion, extension, right bending, left rotation, especially under right bending the right sided FCF of the severe asymmetrical model was about 5.44 times of the neutral position, and 3.14 times of the symmetrical model. and concentrated on the cephalad part of the facets. The facet capsule stresses on both sides remarkably increased under extension, lateral bending and right rotation. In the moderate and severe asymmetrical models, the capsule strain was greater on both sides of each position than in the symmetric model. CONCLUSIONS The face tropism increased facet contact force and facet capsule strain after ACDR, especially under extension, lateral bending, and rotation, and also could result in abnormal stress distribution on the facet joint surface and facet joint capsule. The results suggest that face tropism might be a risk factor for post-operative facet joint degeneration progression after ACDR. Facet tropism may be noteworthy when ACDR is considered as a surgical option.
Collapse
Affiliation(s)
- Jing Li
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China
| | - Yuxiao Deng
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China
| | - Junqi Zhang
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China
| | - Beiyu Wang
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China
| | - Kangkang Huang
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China
| | - Hao Liu
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China
| | - Xin Rong
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China.
| |
Collapse
|
2
|
Wo J, Lv Z, Wang J, Shen K, Zhu H, Liu Y, Huang Y, Sun G, Li Z. Biomechanical Analysis of Cervical Artificial Disc Replacement Using Cervical Subtotal Discectomy Prosthesis. Front Bioeng Biotechnol 2021; 9:680769. [PMID: 34336799 PMCID: PMC8317600 DOI: 10.3389/fbioe.2021.680769] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 06/11/2021] [Indexed: 01/22/2023] Open
Abstract
Background: Anterior cervical discectomy and fusion (ACDF) sacrifices segmental mobility, which can lead to the acceleration of adjacent segment degeneration. The challenge has promoted cervical artificial disc replacement (CADR) as a substitute for ACDF. However, CADR has revealed a series of new issues that are not found in ACDF, such as hypermobility, subsidence, and wear phenomenon. This study designed a cervical subtotal discectomy prosthesis (CSDP) consisting of a cervical disc prosthesis structure (CDP structure), cervical vertebra fixation structure (CVF structure), link structure, and locking screw, aiming to facilitate motion control and reduce subsidence. The aim of this study was to assess the biomechanics of the CSDP using finite element (FE) analysis, friction-wear test, and non-human primates implantation study. Study Design: For the FE analysis, based on an intact FE C2-C7 spinal model, a CSDP was implanted at C5-C6 to establish the CSDP FE model and compare it with the Prestige LP prosthesis (Medtronic Sofamor Danek, Minneapolis, MN, United States). The range of motion (ROM), bone-implant interface stress, and facet joint force were calculated under flexion extension, lateral bending, and axial rotation. In addition, CSDP was elevated 1 mm to mimic an improper implantation technique to analyze the biomechanics of CSDP errors in the FE model. Moreover, the friction-wear test was conducted in vitro to research CSDP durability and observe surface wear morphology and total wear volume. Finally, the CSDP was implanted into non-human primates, and its properties were evaluated and verified by radiology. Results: In the FE analysis, the ROM of the CSDP FE model was close to that of the intact FE model in the operative and adjacent segments. In the operative segment, the CSDP error FE model increased ROM in flexion extension, lateral bending, and axial rotation. The maximum stress in the CSDP FE model was similar to that of the intact FE model and was located in the peripheral cortical bone region. The facet joint force changes were minimal in extension, lateral bending, and axial rotation loads in CSDP. In the friction-wear test, after the 150-W movement simulation, both the CVF-link-junction and the CDP-link-junction had slight wear. In the CSDP non-human primate implantation study, no subsidence, dislocation, or loosening was observed. Conclusion: In the FE analysis, the biomechanical parameters of the CSDP FE model were relatively close to those of the intact FE model when compared with the Prestige LP FE model. In terms of CSDP error FE models, we demonstrated that the implantation position influences CSDP performance, such as ROM, bone-implant interface stress, and facet joint force. In addition, we performed a friction-wear test on the CSDP to prove its durability. Finally, CSDP studies with non-human primates have shown that the CSDP is effective.
Collapse
Affiliation(s)
- Jin Wo
- Department of Orthopedics, First Affiliated Hospital, Jinan University, Guangzhou, China
| | - Zhenjing Lv
- Department of Spine Orthopedics, Guangdong Hospital of Integrated Traditional Chinese and Western Medicine, Foshan, China
| | - Jing Wang
- Department of Neurosurgery, First Affiliated Hospital, Jinan University, Guangzhou, China
| | - Kui Shen
- Department of Orthopedics, First Affiliated Hospital, Jinan University, Guangzhou, China
| | - Haoran Zhu
- Department of Orthopedics, First Affiliated Hospital, Jinan University, Guangzhou, China
| | - Yang Liu
- Department of Orthopedics, First Affiliated Hospital, Jinan University, Guangzhou, China
| | - Yuen Huang
- Department of Rehabilitation, First Affiliated Hospital, Jinan University, Guangzhou, China
| | - Guodong Sun
- Department of Orthopedics, First Affiliated Hospital, Jinan University, Guangzhou, China.,Department of Orthopedics, Fifth Affiliated Hospital, Heyuan Shenhe People's Hospital, Jinan University, Heyuan, China
| | - Zhizhong Li
- Department of Orthopedics, First Affiliated Hospital, Jinan University, Guangzhou, China.,Department of Orthopedics, Fifth Affiliated Hospital, Heyuan Shenhe People's Hospital, Jinan University, Heyuan, China.,Department of Orthopedics, Heyuan People's Hospital, Heyuan Affiliated Hospital of Jinan University, Heyuan, China
| |
Collapse
|
3
|
Roch PJ, Wagner M, Weiland J, Gezzi R, Spiering S, Lehmann W, Saul D, Weiser L, Viezens L, Wachowski MM. Total disc arthroplasties change the kinematics of functional spinal units during lateral bending. Clin Biomech (Bristol, Avon) 2020; 73:130-139. [PMID: 31982810 DOI: 10.1016/j.clinbiomech.2020.01.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Revised: 01/08/2020] [Accepted: 01/10/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND Information about kinematics in different functional spinal units before and after total disc arthroplasties is necessary to improve prostheses and determine indications. There is little information about the nonstationary instantaneous helical axis of rotation under lateral bending in the cervical spine before and after total disc arthroplasty. METHODS Kinematic analyses were performed with an established measuring apparatus on 8 human functional spinal units (C3/C4, C5/C6) under intact conditions and after total disc arthroplasty with two different types of prostheses: Bryan and Prestige. The instantaneous helical axis, migration, and stiffness of the segments were calculated. FINDINGS The instantaneous helical axis direction was always inclined ventrally. Ventral inclination was significantly higher in segment C3/C4 than in segment C5/C6 under all conditions (p < 0.001). Both types of arthroplasties significantly increased ventral inclination compared to intact conditions. In both segments, the path length of the instantaneous helical axis' migration was significantly longer after total disc arthroplasty with Bryan (p = 0.001) and shorter after Prestige (p < 0.001) prostheses than under intact conditions. After both types of arthroplasties, the migration path length was significantly longer and the stiffness was significantly lower in segment C3/C4 than in segment C5/C6. INTERPRETATION Both types of arthroplasties changed the kinematics of both segments during lateral bending. Altered instantaneous helical axis migration, greater ventral inclination and less stiffness after both arthroplasties indicate unphysiological motion. Both arthroplasties had greater impact on segment C3/C4 than on segment C5/C6 in terms of hypermobility. Increased translational motion after total disc arthroplasty with a Bryan prosthesis might be caused by the prosthetic design.
Collapse
Affiliation(s)
- Paul Jonathan Roch
- Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University of Göttingen, Robert-Koch-Str. 40, 37075 Göttingen, Germany.
| | - Markus Wagner
- Department of Ophthalmology, University Hospital Magdeburg, Leipziger Straße 44, 39120 Magdeburg, Germany
| | - Jan Weiland
- Department of Trauma Surgery and Orthopaedics, Hospital Düren gGmbH, Roonstraße 30, 52351 Düren, Germany
| | - Riccardo Gezzi
- Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University of Göttingen, Robert-Koch-Str. 40, 37075 Göttingen, Germany
| | - Stefan Spiering
- Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University of Göttingen, Robert-Koch-Str. 40, 37075 Göttingen, Germany
| | - Wolfgang Lehmann
- Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University of Göttingen, Robert-Koch-Str. 40, 37075 Göttingen, Germany.
| | - Dominik Saul
- Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University of Göttingen, Robert-Koch-Str. 40, 37075 Göttingen, Germany.
| | - Lukas Weiser
- Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University of Göttingen, Robert-Koch-Str. 40, 37075 Göttingen, Germany.
| | - Lennart Viezens
- Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University of Göttingen, Robert-Koch-Str. 40, 37075 Göttingen, Germany.
| | - Martin Michael Wachowski
- Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University of Göttingen, Robert-Koch-Str. 40, 37075 Göttingen, Germany; DUO - Duderstadt Trauma Surgery and Orthopaedics, Westertorstr. 7, 37115 Duderstadt, Germany
| |
Collapse
|
4
|
Sang D, Cui W, Guo Z, Sang H, Liu B. The Differences Among Kinematic Parameters for Evaluating the Quality of Intervertebral Motion of the Cervical Spine in Clinical and Experimental Studies: Concepts, Research and Measurement Techniques. A Literature Review. World Neurosurg 2020; 133:343-357.e1. [DOI: 10.1016/j.wneu.2019.09.075] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 09/13/2019] [Accepted: 09/14/2019] [Indexed: 12/23/2022]
|
5
|
Hu X, Jiang M, Liu H, Rong X, Hong Y, Ding C, Wang B. Five-Year Trends in Center of Rotation After Single-Level Cervical Arthroplasty with the Prestige-LP Disc. World Neurosurg 2019; 132:e941-e948. [DOI: 10.1016/j.wneu.2019.07.042] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Revised: 07/02/2019] [Accepted: 07/03/2019] [Indexed: 12/19/2022]
|
6
|
Havey RM, Khayatzadeh S, Voronov LI, Blank KR, Carandang G, Harding DP, Patwardhan AG. Motion response of a polycrystalline diamond adaptive axis of rotation cervical total disc arthroplasty. Clin Biomech (Bristol, Avon) 2019; 62:34-41. [PMID: 30665037 DOI: 10.1016/j.clinbiomech.2018.12.023] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2018] [Revised: 12/10/2018] [Accepted: 12/20/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND Cervical fusion is associated with adjacent segment degeneration. Cervical disc arthroplasty is considered an alternative to reduce risk of adjacent segment disease. Kinematics after arthroplasty should closely replicate healthy in vivo kinematics to reduce adjacent segment stresses. The purpose of this study was to assess the kinematics of a polycrystalline diamond cervical disc prosthesis. METHODS Nine cadaveric C3-T1 spines were tested intact and after one (C5-C6) and two level (C5-C7) arthroplasty (Triadyme-C, Dymicron Inc., Orem, UT, USA). Kinematics were evaluated in flexion-extension, lateral bending, and axial rotation. FINDINGS Prosthesis placement at C5-C6 and C6-C7 was 0.5 mm anterior and 0.6 mm posterior to midline respectively. C5-C6 flexion-extension motion was 12.8° intact and 10.5° after arthroplasty. C6-C7 flexion-extension motion was 10.0 and 11.4° after arthroplasty. C5-C6 lateral bending reduced from 8.5 to 3.7° after arthroplasty and at C6-C7 from 7.5 to 5.1°. C5-C6 axial rotation decreased from 10.4 to 6.2° after arthroplasty and at C6-C7 from 7.8 to 5.3°. Segmental lordosis increased by 4.2°, and middle disc height by 1.4 mm after arthroplasty. Change in center of rotation from intact to arthroplasty averaged 0.9 mm posteriorly and 0.1 mm caudally at C5-C6, and 1.4 mm posteriorly and 0.3 mm cranially at C6-C7. INTERPRETATION The cervical disc arthroplasty evaluated restored flexion-extension motion to intact levels and moderately increased segmental stiffness. Disc height increased by up to 1.5 mm and segmental lordosis by 4.2°. The unique prosthesis design allowed the axis of rotation after arthroplasty to closely mimic the native location.
Collapse
Affiliation(s)
- Robert M Havey
- Edward Hines Jr. VA Hospital, Hines, IL, USA; Loyola University Medical Center, Maywood, IL, USA.
| | | | - Leonard I Voronov
- Edward Hines Jr. VA Hospital, Hines, IL, USA; Loyola University Medical Center, Maywood, IL, USA
| | | | | | | | - Avinash G Patwardhan
- Edward Hines Jr. VA Hospital, Hines, IL, USA; Loyola University Medical Center, Maywood, IL, USA
| |
Collapse
|
7
|
Chang CC, Huang WC, Wu JC, Mummaneni PV. The Option of Motion Preservation in Cervical Spondylosis: Cervical Disc Arthroplasty Update. Neurospine 2018; 15:296-305. [PMID: 30545210 PMCID: PMC6347355 DOI: 10.14245/ns.1836186.093] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Accepted: 08/28/2018] [Indexed: 12/22/2022] Open
Abstract
Cervical disc arthroplasty (CDA), or total disc replacement, has emerged as an option in the past two decades for the management of 1- and 2-level cervical disc herniation and spondylosis causing radiculopathy, myelopathy, or both. Multiple prospective randomized controlled trials have demonstrated CDA to be as safe and effective as anterior cervical discectomy and fusion, which has been the standard of care for decades. Moreover, CDA successfully preserved segmental mobility in the majority of surgical levels for 5–10 years. Although CDA has been suggested to have long-term efficacy for the reduction of adjacent segment disease in some studies, more data are needed on this topic. Surgery for CDA is more demanding for decompression, because indirect decompression by placement of a tall bone graft is not possible in CDA. The artificial discs should be properly sized, centered, and installed to allow movement of the vertebrae, and are commonly 6 mm high or less in most patients. The key to successful CDA surgery includes strict patient selection, generous decompression of the neural elements, accurate sizing of the device, and appropriately centered implant placement.
Collapse
Affiliation(s)
- Chih-Chang Chang
- Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan.,School of Medicine, National Yang-Ming University, Taipei, Taiwan
| | - Wen-Cheng Huang
- Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan.,School of Medicine, National Yang-Ming University, Taipei, Taiwan
| | - Jau-Ching Wu
- Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan.,School of Medicine, National Yang-Ming University, Taipei, Taiwan
| | - Praveen V Mummaneni
- Department of Neurosurgery, University of California, San Francisco, San Francisco, CA, USA
| |
Collapse
|
8
|
Lou J, Li Y, Wang B, Meng Y, Wu T, Liu H. In vitro biomechanical comparison after fixed- and mobile-core artificial cervical disc replacement versus fusion. Medicine (Baltimore) 2017; 96:e8291. [PMID: 29019902 PMCID: PMC5662325 DOI: 10.1097/md.0000000000008291] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
In vitro biomechanical analysis after cervical disc replacement (CDR) with a novel artificial disc prosthesis (mobile core) was conducted and compared with the intact model, simulated fusion, and CDR with a fixed-core prosthesis. The purpose of this experimental study was to analyze the biomechanical changes after CDR with a novel prosthesis and the differences between fixed- and mobile-core prostheses.Six human cadaveric C2-C7 specimens were biomechanically tested sequentially in 4 different spinal models: intact specimens, simulated fusion, CDR with a fixed-core prosthesis (Discover, DePuy), and CDR with a mobile-core prosthesis (Pretic-I, Trauson). Moments up to 2 Nm with a 75 N follower load were applied in flexion-extension, left and right lateral bending, and left and right axial rotation. The total range of motion (ROM), segmental ROM, and adjacent intradiscal pressure (IDP) were calculated and analyzed in 4 different spinal models, as well as the differences between 2 disc prostheses.Compared with the intact specimens, the total ROM, segmental ROM, and IDP at the adjacent segments showed no significant difference after arthroplasty. Moreover, CDR with a mobile-core prosthesis presented a little higher values of target segment (C5/6) and total ROM than CDR with a fixed-core prosthesis (P > .05). Besides, the difference in IDP at C4/5 after CDR with 2 prostheses was without statistical significance in all the directions of motion. However, the IDP at C6/7 after CDR with a mobile-core prosthesis was lower than CDR with a fixed-core prosthesis in flexion, extension, and lateral bending, with significant difference (P < .05), but not under axial rotation.CDR with a novel prosthesis was effective to maintain the ROM at the target segment and did not affect the ROM and IDP at the adjacent segments. Moreover, CDR with a mobile-core prosthesis presented a little higher values of target segment and total ROM, but lower IDP at the inferior adjacent segment than CDR with a fixed-core prosthesis.
Collapse
Affiliation(s)
- Jigang Lou
- Department of Orthopedics, West China Hospital, Sichuan University, Chengdu, Sichuan
| | - Yuanchao Li
- Department of Biomechanical Research Laboratory, Shanghai Jiao Tong University, Shanghai, China
| | - Beiyu Wang
- Department of Orthopedics, West China Hospital, Sichuan University, Chengdu, Sichuan
| | - Yang Meng
- Department of Orthopedics, West China Hospital, Sichuan University, Chengdu, Sichuan
| | - Tingkui Wu
- Department of Orthopedics, West China Hospital, Sichuan University, Chengdu, Sichuan
| | - Hao Liu
- Department of Orthopedics, West China Hospital, Sichuan University, Chengdu, Sichuan
| |
Collapse
|
9
|
A Biomechanical Analysis of an Artificial Disc With a Shock-absorbing Core Property by Using Whole-cervical Spine Finite Element Analysis. Spine (Phila Pa 1976) 2016; 41:E893-E901. [PMID: 26825785 DOI: 10.1097/brs.0000000000001468] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN A biomechanical comparison among the intact C2 to C7 segments, the C5 to C6 segments implanted with fusion cage, and three different artificial disc replacements (ADRs) by finite element (FE) model creation reflecting the entire cervical spine below C2. OBJECTIVE The aim of this study was to analyze the biomechanical changes in subaxial cervical spine after ADR and to verify the efficacy of a new mobile core artificial disc Baguera C that is designed to absorb shock. SUMMARY OF BACKGROUND DATA Scarce references could be found and compared regarding the cervical ADR devices' biomechanical differences that are consequently related to their different clinical results. METHODS One fusion device (CJ cage system, WINNOVA) and three different cervical artificial discs (Prodisc-C Nova (DePuy Synthes), Discocerv (Scient'x/Alphatec), Baguera C (Spineart)) were inserted at C5-6 disc space inside the FE model and analyzed. Hybrid loading conditions, under bending moments of 1 Nm along flexion, extension, lateral bending, and axial rotation with a compressive force of 50 N along the follower loading direction, were used in this study. Biomechanical behaviors such as segmental mobility, facet joint forces, and possible wear debris phenomenon inside the core were investigated. RESULTS The segmental motions as well as facet joint forces were exaggerated after ADR regardless of type of the devices. The Baguera C mimicked the intact cervical spine regarding the location of the center of rotation only during the flexion moment. It also showed a relatively wider distribution of the contact area and significantly lower contact pressure distribution on the core than the other two devices. A "lift off" phenomenon was noted for other two devices according to the specific loading condition. CONCLUSION The mobile core artificial disc Baguera C can be considered biomechanically superior to other devices by demonstrating no "lift off" phenomenon, and significantly lower contact pressure distribution on core. LEVEL OF EVIDENCE N/A.
Collapse
|
10
|
TANG QIAOHONG, WANG LIZHEN, MO ZHONGJUN, LI QI, YAO JIE, DU CHENGFEI, FAN YUBO. BIOMECHANICAL ANALYSIS OF DIFFERENT PRODISC-C ARTHROPLASTY DESIGNS AFTER IMPLANTATION: A NUMERICAL SENSITIVITY STUDY. J MECH MED BIOL 2015. [DOI: 10.1142/s0219519415500074] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Ball-and-socket disc prostheses are the leading type of artificial disc replacement (ADR) and are typically used to treat degenerative cervical spine instability. Previous publications focused on the influence of different ProDisc-C design parameters in view of biomechanics. However, more beneficial data could be gathered if the implant was implanted prior to testing. Therefore, this study aimed to estimate the effect of different ProDisc-C arthroplasty designs and alignments when implanted at the C5-6 segment. This research can provide advice on the design of artificial discs as well as optimal placement. The geometry of the vertebrae was developed based on computed tomography (CT) images of a 32-year-old healthy male (170 cm height and 68 kg weight) with a slice thickness of 0.625 mm. A finite element (FE) model of intact C5–C6 segments including vertebrae and disc was developed and validated. A ball-and-socket artificial disc prosthesis model (ProDisc-C, Synthes) was implanted into the validated FE model. The curvature of the ProDisc-C prosthesis as well as the implanted position was varied. All models were loaded with a 74 N compressive force and pure moments of 1.8 Nm in flexion-extension, bilateral bending and axial torsion. The radius of the artificial disc influenced the ROM, facet joint force and capsule ligament tension only in flexion, while the position influenced these aspects in all loading conditions. The disc with a 6 mm radius had a greater ROM in flexion, and lower stress on the polyethylene (PE) insert without apparent stress concentrations, but it had a greater facet joint force and ligament tension compared to other radii. For all the designs, the implant position in the anterior–posterior direction had a significant influence on the disc biomechanics. Disc design and surgical procedure, such as implantation position, are important factors in postoperative rehabilitation, especially regarding the ROM in flexion/extension and implant stress. Thus, a suitable disc design should consider preserving an adequate range of motion (ROM) as well as a moderate facet joint force or stress, and proper implant positioning along the anterior–posterior direction should be monitored.
Collapse
Affiliation(s)
- QIAOHONG TANG
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, 100191 Beijing, P. R. China
- International Joint Research Center of Aerospace, Biotechnology and Medical Engineering, Ministry of Science and Technology of China, 100191 Beijing, P. R. China
| | - LIZHEN WANG
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, 100191 Beijing, P. R. China
- International Joint Research Center of Aerospace, Biotechnology and Medical Engineering, Ministry of Science and Technology of China, 100191 Beijing, P. R. China
| | - ZHONGJUN MO
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, 100191 Beijing, P. R. China
- International Joint Research Center of Aerospace, Biotechnology and Medical Engineering, Ministry of Science and Technology of China, 100191 Beijing, P. R. China
| | - QI LI
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, 100191 Beijing, P. R. China
- International Joint Research Center of Aerospace, Biotechnology and Medical Engineering, Ministry of Science and Technology of China, 100191 Beijing, P. R. China
| | - JIE YAO
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, 100191 Beijing, P. R. China
- International Joint Research Center of Aerospace, Biotechnology and Medical Engineering, Ministry of Science and Technology of China, 100191 Beijing, P. R. China
| | - CHENGFEI DU
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, 100191 Beijing, P. R. China
- International Joint Research Center of Aerospace, Biotechnology and Medical Engineering, Ministry of Science and Technology of China, 100191 Beijing, P. R. China
| | - YUBO FAN
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, 100191 Beijing, P. R. China
- International Joint Research Center of Aerospace, Biotechnology and Medical Engineering, Ministry of Science and Technology of China, 100191 Beijing, P. R. China
| |
Collapse
|
11
|
The effect of deviated center of rotation on flexion-extension range of motion after single-level cervical arthroplasty: an in vivo study. Spine (Phila Pa 1976) 2014; 39:B12-8. [PMID: 25271518 DOI: 10.1097/brs.0000000000000634] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN A retrospective study. OBJECTIVE To report the clinical outcomes and sagittal kinematics after cervical total disc replacement (TDR). To evaluate the in vivo effect of deviated center of rotation (COR) on flexion-extension range of motion (ROM) at the instrumented level. SUMMARY OF BACKGROUND DATA A few studies showed that the location of COR after cervical TDR deviated from its preoperative location or inherent location in healthy subjects. However, little is known about the effect of deviated COR on ROM at the instrumented level. METHODS A total of 24 patients who underwent C5-C6 single-level TDR with Prestige LP (Medtronic Sofamor Danek) were retrospectively included. Japanese Orthopedic Association score and visual analogue scale were used to assess the clinical outcomes. ROM and COR were measured for radiographical analysis. Patients were categorized into 2 groups according to the change of ROM for further evaluation. Group 1, characterized by decreased postoperative ROM, consisted of 16 patients; group 2, characterized by increased postoperative ROM, consisted of 8 patients. RESULTS Ten males and 14 females comprised the study cohort. The mean age was 45.05 years, and the mean follow-up time was 15.5 months. The Japanese Orthopedic Association score increased significantly and the neck and arm visual analogue scale decreased significantly after cervical TDR. On average, ROM was preserved after cervical TDR. The postoperative COR had a significant cranial shift from its preoperative location. The COR shift in anterior-posterior direction was larger in group 2 than that in group 1. No difference was observed in the COR shift in cranial-caudal direction between the 2 groups. CONCLUSION Single-level cervical TDR with Prestige LP obtained satisfactory clinical outcomes and partially restored the natural cervical kinematics. At instrumented level, the deviated COR had a negative correlation with the flexion-extension ROM.
Collapse
|
12
|
Smith JS, Helgeson MD, Albert TJ. The Argument for Anterior Cervical Diskectomy and Fusion Over Total Disk Replacement. ACTA ACUST UNITED AC 2012. [DOI: 10.1053/j.semss.2011.11.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
13
|
Jaumard NV, Welch WC, Winkelstein BA. Spinal facet joint biomechanics and mechanotransduction in normal, injury and degenerative conditions. J Biomech Eng 2011; 133:071010. [PMID: 21823749 DOI: 10.1115/1.4004493] [Citation(s) in RCA: 214] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
The facet joint is a crucial anatomic region of the spine owing to its biomechanical role in facilitating articulation of the vertebrae of the spinal column. It is a diarthrodial joint with opposing articular cartilage surfaces that provide a low friction environment and a ligamentous capsule that encloses the joint space. Together with the disc, the bilateral facet joints transfer loads and guide and constrain motions in the spine due to their geometry and mechanical function. Although a great deal of research has focused on defining the biomechanics of the spine and the form and function of the disc, the facet joint has only recently become the focus of experimental, computational and clinical studies. This mechanical behavior ensures the normal health and function of the spine during physiologic loading but can also lead to its dysfunction when the tissues of the facet joint are altered either by injury, degeneration or as a result of surgical modification of the spine. The anatomical, biomechanical and physiological characteristics of the facet joints in the cervical and lumbar spines have become the focus of increased attention recently with the advent of surgical procedures of the spine, such as disc repair and replacement, which may impact facet responses. Accordingly, this review summarizes the relevant anatomy and biomechanics of the facet joint and the individual tissues that comprise it. In order to better understand the physiological implications of tissue loading in all conditions, a review of mechanotransduction pathways in the cartilage, ligament and bone is also presented ranging from the tissue-level scale to cellular modifications. With this context, experimental studies are summarized as they relate to the most common modifications that alter the biomechanics and health of the spine-injury and degeneration. In addition, many computational and finite element models have been developed that enable more-detailed and specific investigations of the facet joint and its tissues than are provided by experimental approaches and also that expand their utility for the field of biomechanics. These are also reviewed to provide a more complete summary of the current knowledge of facet joint mechanics. Overall, the goal of this review is to present a comprehensive review of the breadth and depth of knowledge regarding the mechanical and adaptive responses of the facet joint and its tissues across a variety of relevant size scales.
Collapse
Affiliation(s)
- Nicolas V Jaumard
- Dept. of Neurosurgery, University of Pennsylvania, Philadelphia, PA 19104, USA.
| | | | | |
Collapse
|
14
|
[Cervical arthroplasty using the Bryan Cervical Disc System]. OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE 2010; 22:468-79. [PMID: 21153006 DOI: 10.1007/s00064-010-9031-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE Treatment of radicular or myelopathic symptoms of the vertebral segments from C2 through Th1. INDICATIONS Discogenic and/or spondylotic radiculopathy. Acute myelopathy. Acute or progressive functional neurological deficit. Persistent pain resistant toward conservative treatment for > 6 weeks. CONTRAINDICATIONS Chronic myelopathy. Spondylotic myelopathy. Infection. Tumor in the vertebral segment. Ossification of the posterior longitudinal ligament (OPLL). Metabolic bone disease. Osteoporosis. Long-lasting steroid medication. Allergy to titanium, polyurethane and ethylene oxide. Bekhterev's disease. Bony segmental fusion. Instability. SURGICAL TECHNIQUE Using the Bryan Cervical Disc Template Set together with magnetic resonance or computer tomographic images, the exact size of the prosthesis will be selected. The patient is lying in a supine position and the level of surgery is verified fluoroscopically. Diskectomy and decompression are performed via an anterior approach. After preparation of the implant bed, the center of the disk space is established using a transverse centering tool and inserting the Bryan cervical distractor. Before the prosthesis can be inserted, the end plates have to be milled. The prosthesis is filled with sterile saline solution and inserted. Proper fitting is verified fluoroscopically. POSTOPERATIVE MANAGEMENT Depending on the clinical situation postoperatively, the patient is discharged. Wound clamps are distracted on day 8, support by a cervical collar is not necessary. Light physical manipulations for muscle relaxation can be performed. RESULTS Since 2002, 178 patients have received at least one Bryan Cervical Disc Prosthesis. 92 patients had a complete follow- up. Examinations were performed 8 and 12 weeks, respectively, as well as 6 up to 44 months postoperatively. 29 patients received a hybrid implantation. Cobb's angle and range of motion were determined radiologically, the degree of heterotopic ossification was classified according to McAfee. Disk prosthesis placement was measured in relation to the dorsal edge of the vertebral body, the center of the spine, as well as the body axes. For clinical evaluation, the Oswestry Neck Disability Index was used, and the neurostatus was determined.
Collapse
|
15
|
Cervical Spine Arthroplasty: Kinematics of Cervical Arthroplasty. Tech Orthop 2010. [DOI: 10.1097/bto.0b013e3181de3793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|