1
|
O'Connor A, Byrne CM, Vasant DH, Sharma A, Liao D, Klarskov N, Kiff ES, Telford K. Current and future perspectives on the utility of provocative tests of anal sphincter function: A state-of-the-art summary. Neurogastroenterol Motil 2022:e14496. [PMID: 36377815 DOI: 10.1111/nmo.14496] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Revised: 10/18/2022] [Accepted: 11/01/2022] [Indexed: 11/16/2022]
Abstract
BACKGROUND The maintenance of fecal continence depends upon coordinated interactions between the pelvic floor, anorectum, and anal sphincter complex orchestrated by central and peripheral neural activities. The current techniques to objectively measure anorectal function rely on fixed diameter catheters placed inside the anal canal with a rectal balloon to obtain measurements of anal resting and squeeze function, and rectal compliance. Until recently it had not been possible to measure the distensibility of the anal canal, or in other words its ability to resist opening against an increasing pressure, which has been proposed as the main determinant of a biological sphincter's function. Anal acoustic reflectometry (AAR) and the functional lumen imaging probe (FLIP) are two novel, provocative techniques that dynamically assess the anal sphincter complex under volume-controlled distension. In doing so, both provide information on the viscoelastic properties of the anal canal and offer new insights into its function. PURPOSE This review details the current and potential future applications of AAR and FLIP and highlights the unanswered questions relevant to these new technologies.
Collapse
Affiliation(s)
- Alexander O'Connor
- Faculty of Biology, Medicine, and Health, The University of Manchester, Manchester, UK.,Department of Colorectal Surgery, Wythenshawe Hospital, Manchester University NHS Foundation Trust, Manchester, UK
| | - Caroline M Byrne
- Department of Colorectal Surgery, Wythenshawe Hospital, Manchester University NHS Foundation Trust, Manchester, UK
| | - Dipesh H Vasant
- Neurogastroenterology Unit, Gastroenterology, Wythenshawe Hospital, Manchester University NHS Foundation Trust, Manchester, UK.,Division of Diabetes, Endocrinology and Gastroenterology, The University of Manchester, Manchester, UK
| | - Abhiram Sharma
- Faculty of Biology, Medicine, and Health, The University of Manchester, Manchester, UK.,Department of Colorectal Surgery, Wythenshawe Hospital, Manchester University NHS Foundation Trust, Manchester, UK
| | - Donghua Liao
- Mech-Sense, Department of Gastroenterology and Hepatology, Aalborg University Hospital, Aalborg, Denmark
| | - Niels Klarskov
- Department of Obstetrics and Gynecology, Herlev University Hospital, Herlev, Denmark.,Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Edward S Kiff
- Department of Colorectal Surgery, Wythenshawe Hospital, Manchester University NHS Foundation Trust, Manchester, UK
| | - Karen Telford
- Faculty of Biology, Medicine, and Health, The University of Manchester, Manchester, UK.,Department of Colorectal Surgery, Wythenshawe Hospital, Manchester University NHS Foundation Trust, Manchester, UK
| |
Collapse
|
2
|
Mittal RK, Tuttle LJ. Anorectal Anatomy and Function. Gastroenterol Clin North Am 2022; 51:1-23. [PMID: 35135656 DOI: 10.1016/j.gtc.2021.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2023]
Abstract
Anatomy of pelvic floor muscles has long been controversial. Novel imaging modalities, such as three-dimensional transperineal ultrasound imaging, MRI, and diffusion tensor imaging, have revealed unique myoarchitecture of the external anal sphincter and puborectalis muscle. High-resolution anal manometry, high-definition anal manometry, and functional luminal imaging probe are important new tools to assess anal sphincter and puborectalis muscle function. Increased understanding of the structure and function of anal sphincter complex/pelvic floor muscle has improved the ability to diagnose patients with pelvic floor disorders. New therapeutic modalities to treat anal/fecal incontinence and other pelvic floor disorders will emerge in the near future.
Collapse
Affiliation(s)
- Ravinder K Mittal
- Department of Medicine/Gastroenterology, University of California, San Diego, ACTRI, 9500 Gilman Drive, MC 0061, La Jolla, CA 92093-0990, USA.
| | - Lori J Tuttle
- Department of Medicine/Gastroenterology, University of California, San Diego, USA; San Diego State University, San Diego, CA, USA
| |
Collapse
|
3
|
Sorkhi S, Seo Y, Bhargava V, Rajasekaran MR. Preclinical applications of high-definition manometry system to investigate pelvic floor muscle contribution to continence mechanisms in a rabbit model. Am J Physiol Gastrointest Liver Physiol 2022; 322:G134-G141. [PMID: 34877885 PMCID: PMC8742739 DOI: 10.1152/ajpgi.00295.2021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
External anal sphincter (EAS), external urethral sphincters, and puborectalis muscle (PRM) have important roles in the genesis of anal and urethral closure pressures. In the present study, we defined the contribution of these muscles alone and in combination with the sphincter closure function using a rabbit model and a high-definition manometry (HDM) system. A total of 12 female rabbits were anesthetized and prepared to measure anal, urethral, and vaginal canal pressures using a HDM system. Pressure was recorded at rest and during electrical stimulation of the EAS and PRM. A few rabbits (n = 6) were subjected to EAS injury and the impact of EAS injury on the closure pressure profile was also evaluated. Anal, urethral, and vaginal canal pressures recorded at rest and during electrical stimulation of EAS and PRM demonstrated distinct pressure profiles. EAS stimulation induced anal canal pressure increase, whereas PRM stimulation increased the pressures in all the three orifices. Electrical stimulation of EAS after injury resulted in about 19% decrease in anal canal pressure. Simultaneous electrical stimulation of EAS and PRM resulted in an insignificant increase of individual anal canal pressures when compared with pressures recorded after EAS or PRM stimulations alone. Our data confirm that HDM is a viable system to measure dynamic pressure changes within the three orifices and to define the role of each muscle in the development of closure pressures within these orifices in preclinical studies.NEW & NOTEWORTHY We anticipate that with this new HDM technology, physiological changes within these orifices may be redefined using the extensive data that are generated from 96 sensors. When compared with conventional methods, HDM offers the advantages of an increased response rate, as well as the utilization of 96 circumferential sensors to simultaneously measure pressure along the three orifices. Our findings suggest a potential use of this technology to better define urinary leak point pressure.
Collapse
Affiliation(s)
- Samuel Sorkhi
- 1Department of Urology, University of California San Diego Medical Center, San Diego, California
| | - Youngjin Seo
- 1Department of Urology, University of California San Diego Medical Center, San Diego, California
| | - Valmik Bhargava
- 2Department of Medicine, University of California San Diego Medical Center, San Diego, California
| | - Mahadevan Raj Rajasekaran
- 1Department of Urology, University of California San Diego Medical Center, San Diego, California,3San Diego Veterans Affairs Health Care System, San Diego, California
| |
Collapse
|
4
|
Litta F, Marra AA, Ortega Torrecilla N, Orefice R, Parello A, De Simone V, Campennì P, Goglia M, Ratto C. Implant of Self-Expandable Artificial Anal Sphincter in Patients With Fecal Incontinence Improves External Anal Sphincter Contractility. Dis Colon Rectum 2021; 64:706-713. [PMID: 33496487 DOI: 10.1097/dcr.0000000000001857] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
BACKGROUND External anal sphincter contractility significantly contributes to control the passage of stool. An artificial anal sphincter placed into the intersphincteric space is a safe and effective procedure to treat fecal incontinence, even if its mechanism of action has not been fully elucidated. OBJECTIVE The aim of this study was to evaluate external anal sphincter contractility changes after a self-expandable hyexpan prostheses was implanted into the intersphincteric space of the anal canal and clinical outcomes compared. DESIGN This was a prospective clinical study. SETTINGS The study was conducted at a university teaching hospital. PATIENTS Consecutive patients affected by fecal incontinence for at least 6 months after failure of conservative treatment were included. INTERVENTIONS All of the patients underwent 10-prostheses implantation and were examined preoperatively and postoperatively by endoanal ultrasound and anorectal manometry. MAIN OUTCOME MEASURES Fecal incontinence symptoms were assessed by severity scores. The external anal sphincter muscle tension was calculated using a specific equation. RESULTS Thirty-nine patients (34 women; median age = 68 y) were included in the study; no morbidity was registered. After a median follow-up period of 14 months, both the median maximum voluntary squeeze pressure and the median inner radius of the external anal sphincter significantly increased. A statistically significant increase of external anal sphincter muscle tension was detected. A decrease of any fecal incontinence symptom and an improvement in severity scores were observed at the last follow-up examination. The external anal sphincter contractility was significantly higher in patients reducing incontinence episodes to solid stool by >50% and improving their ability to defer defecation for >15 minutes. LIMITATIONS This was a single-center experience with a relatively small and heterogeneous sample size, patients with a potentially more severe disease because our institution is a referral center, and an absence of quality-of-life evaluation. CONCLUSIONS Artificial anal sphincter implantation improved the external anal sphincter muscle tension; there was a positive correlation between its increase and the clinical outcome. See Video Abstract at http://links.lww.com/DCR/B468. IMPLANTE DE ESFNTER ANAL ARTIFICIAL AUTOEXPANDIBLE EN PACIENTES CON INCONTINENCIA FECAL MEJORA LA CONTRACTILIDAD DEL ESFNTER ANAL EXTERNO ANTECEDENTES:La contractilidad del esfínter anal externo contribuye significativamente al control del paso de las heces. Un esfínter anal artificial colocado en el espacio interesfinteriano es un procedimiento seguro y eficaz para tratar la incontinencia fecal, incluso si su mecanismo de acción no se ha definido por completo.OBJETIVO:El objetivo de este estudio fue evaluar los cambios en la contractilidad del esfínter anal externo después de la implantación de una prótesis de hyexpan autoexpandible en el espacio interesfinteriano del canal anal y comparar los resultados clínicos.DISEÑO:Estudio clínico prospectivo.ENTORNO CLINICO:El estudio se realizó en un hospital universitario.PACIENTES:Pacientes consecutivos afectados por incontinencia fecal durante al menos 6 meses, tras fracaso de tratamiento conservador.INTERVENCIONES:Todos los pacientes fueron sometidos a la implantación de 10 prótesis, y fueron examinados pre y postoperatoriamente mediante ecografía endoanal y manometría anorrectal.PRINCIPALES MEDIDAS DE VALORACION:Los síntomas de incontinencia fecal se evaluaron mediante puntuaciones de gravedad. La tensión del músculo del esfínter anal externo se calculó mediante una formula específica.RESULTADOS:Treinta y nueve pacientes (34 mujeres; mediana de edad 68 años) fueron incluidos en el estudio; no se registró morbilidad. Después de un período de seguimiento medio de 14 meses, tanto la presión de compresión voluntaria máxima media como el radio interior medio del esfínter anal externo aumentaron significativamente. Se detectó un aumento estadísticamente significativo de la tensión del músculo del esfínter anal externo. En el último examen de seguimiento se observó una disminución de cualquier síntoma de incontinencia fecal y una mejora en las puntuaciones de gravedad. La contractilidad del esfínter anal externo fue significativamente mayor en los pacientes que redujeron los episodios de incontinencia a heces sólidas en más del 50% y mejoraron la capacidad para diferir la defecación durante más de 15 minutos.LIMITACIONES:Experiencia de un solo centro; tamaño de muestra relativamente pequeño y heterogéneo; pacientes con una enfermedad potencialmente más grave porque nuestra institución es un centro de referencia; ausencia de evaluación de la calidad de vida.CONCLUSIONES:La implantación del esfínter anal artificial mejoró la tensión muscular del esfínter anal externo; hubo una correlación positiva entre su aumento y el resultado clínico. Consulte Video Resumen en http://links.lww.com/DCR/B468.
Collapse
Affiliation(s)
- Francesco Litta
- Proctology Unit, Fondazione Policlinico Universitario Agostino Gemelli IRCCS Rome, Italy
| | - Angelo A Marra
- Proctology Unit, Fondazione Policlinico Universitario Agostino Gemelli IRCCS Rome, Italy
| | | | - Raffaele Orefice
- Proctology Unit, Fondazione Policlinico Universitario Agostino Gemelli IRCCS Rome, Italy
| | - Angelo Parello
- Proctology Unit, Fondazione Policlinico Universitario Agostino Gemelli IRCCS Rome, Italy
| | - Veronica De Simone
- Proctology Unit, Fondazione Policlinico Universitario Agostino Gemelli IRCCS Rome, Italy
| | - Paola Campennì
- Proctology Unit, Fondazione Policlinico Universitario Agostino Gemelli IRCCS Rome, Italy
| | - Marta Goglia
- Proctology Unit, Fondazione Policlinico Universitario Agostino Gemelli IRCCS Rome, Italy
| | - Carlo Ratto
- Proctology Unit, Fondazione Policlinico Universitario Agostino Gemelli IRCCS Rome, Italy
- Università Cattolica del Sacro Cuore, Rome, Italy
| |
Collapse
|
5
|
Zifan A, Mittal RK, Kunkel DC, Swartz J, Barr G, Tuttle LJ. Loop analysis of the anal sphincter complex in fecal incontinent patients using functional luminal imaging probe. Am J Physiol Gastrointest Liver Physiol 2020; 318:G66-G76. [PMID: 31736339 PMCID: PMC6985842 DOI: 10.1152/ajpgi.00164.2019] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Cardiac loops have been used extensively to study myocardial function. With changes in cardiac pump function, loops are shifted to the right or left. Functional luminal imaging probe (FLIP) recordings allow for loop analysis of the anal sphincter and puborectalis muscle (PRM) function. The goal was to characterize anal sphincter area-pressure/tension loop changes in fecal incontinence (FI) patients. Fourteen healthy subjects and 14 patients with FI were studied. A custom-designed FLIP was placed in the vagina and then in the anal canal, and deflated in 20-ml steps, from 90 to 30 ml. At each volume, subjects performed maximal voluntary squeezes. Area-pressure (AP) and area-tension (AT) loops were generated for each squeeze cycle. Three-dimensional ultrasound imaging of the anal sphincter and PRM were obtained to determine the relationship between anal sphincter muscle damage and loop movements. With the increase in bag volume, AP loops and AT loops shifted to the right and upward in normal subjects (both anal and vaginal). The shift to the right was greater, and the upward movement was less in FI patients. The difference in the location of AP loops and AT loops was statistically significant at volumes of 50 ml to 90 ml (P < 0.05). A similar pattern was found in the vaginal loops. There is a significant relationship between the damage to the anal sphincter and PRM, and loop location of FI patients. We propose AP and AT loops as novel ways to assess the anal sphincter and PRM function. Such loops can be generated by real-time measurement of pressure and area within the anal canal.NEW & NOTEWORTHY We describe the use of area-pressure (AP) and area-tension (AT)-loop analysis of the anal sphincters and puborectalis muscles in normal subjects and fecal incontinent patients using the functional luminal imaging probe (FLIP). There are differences in the magnitude of the displacement of the loops with increase in the FLIP bag volume between normal subjects and patients with fecal incontinence. The latter group shifts more to the right in AP and AT space.
Collapse
Affiliation(s)
- Ali Zifan
- 1Division of Gastroenterology, Department of Medicine, University of California San Diego, California
| | - Ravinder K. Mittal
- 1Division of Gastroenterology, Department of Medicine, University of California San Diego, California
| | - David C. Kunkel
- 1Division of Gastroenterology, Department of Medicine, University of California San Diego, California
| | - Jessica Swartz
- 2Doctor of Physical Therapy Program, School of Exercise and Nutritional Sciences, San Diego State University, San Diego, California
| | - Garrett Barr
- 2Doctor of Physical Therapy Program, School of Exercise and Nutritional Sciences, San Diego State University, San Diego, California
| | - Lori J. Tuttle
- 2Doctor of Physical Therapy Program, School of Exercise and Nutritional Sciences, San Diego State University, San Diego, California
| |
Collapse
|
6
|
Grossi U, De Simone V, Parello A, Litta F, Donisi L, Di Tanna GL, Goglia M, Ratto C. Gatekeeper Improves Voluntary Contractility in Patients With Fecal Incontinence. Surg Innov 2018; 26:321-327. [PMID: 30547721 PMCID: PMC6535806 DOI: 10.1177/1553350618818924] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Background. Gatekeeper (GK) has shown to be safe and effective in patients with fecal incontinence (FI). We aimed to understand its mechanism of action by comparing pre- and post-implant change in the external anal sphincter (EAS) contractility. Methods. Study of EAS contractility was conducted in 16 FI females (median age = 69 years) before and after implant of 6 GK prostheses. Muscle tension (Tm), expressed in millinewtons per centimeter squared, mN(cm2)−1, was calculated using the equation Tm = P(ri)(tm)−1, where P is the average maximum squeeze pressure and ri and tm the inner radius and thickness of the EAS, respectively. The effect of a predefined set of covariates on Tm was tested by restricted maximum likelihood models. Results. Compared with baseline, despite unchanged tm (2.7 [2.5-2.8] vs 2.5 [2.2-2.8] mm; P = .31 mm), a significant increase in P (median = 45.8 [26.5-75.8] vs 60.4 [43.1-88.1] mm Hg; P = .017), and ri (12.4 [11.5-13.4] vs 18.7 [17.3-19.6] mm; P < .001) resulted in an increase in Tm (233.2 [123.8-303.2] vs 490.8 [286.9-562.4] mN(cm2)−1; P < .001) at 12 months after GK implant. Twelve-month follow-up improvements were also observed on Cleveland Clinic FI score (8-point median decrease; P = .0001), St Marks FI score (10-point median decrease; P < .0001), and American Medical Systems score (39-point median decrease; P < .0001). Restricted maximum likelihood models showed that years of onset of FI was negatively associated with change in Tm (P = .048). Conclusions. GK-related EAS compression positively influences muscle contractility by increasing ri, with consequent increase in Tm (length-tension relationship). Further studies are needed to confirm the long-term effectiveness of GK.
Collapse
Affiliation(s)
- Ugo Grossi
- 1 Proctology Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Veronica De Simone
- 1 Proctology Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Angelo Parello
- 1 Proctology Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Francesco Litta
- 1 Proctology Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Lorenza Donisi
- 1 Proctology Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | | | - Marta Goglia
- 1 Proctology Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Carlo Ratto
- 1 Proctology Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.,3 Università Cattolica del Sacro Cuore, Rome, Italy
| |
Collapse
|
7
|
Tuttle LJ, Zifan A, Sun C, Swartz J, Roalkvam S, Mittal RK. Measuring length-tension function of the anal sphincters and puborectalis muscle using the functional luminal imaging probe. Am J Physiol Gastrointest Liver Physiol 2018; 315:G781-G787. [PMID: 30160982 PMCID: PMC6293252 DOI: 10.1152/ajpgi.00414.2017] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
The functional luminal imaging probe (FLIP) has been used to measure the distensibility of the anal canal. We hypothesized that with increasing distension of the anal canal with FLIP there will be an increase in length of the anal sphincter muscle allowing measurement of the length-tension function of anal sphincter and puborectalis muscles (PRM). We studied 14 healthy nulliparous women. A custom-designed FLIP bag (30-mm diameter) was placed in the vagina and then in the anal canal, distended in 10-ml steps with volumes ranging from 30 to 90 ml. At each volume, subject performed maximal voluntary squeezes. Length-tension measurements were also made with a manometric probe system. Tension was calculated (pressure × radius) in Newtons per meter using a custom software program. Peak tensions at different FLIP volumes were compared with the manometric data. No change in the luminal CSA was noted at low fluid volumes; the sphincter muscles were able to fully collapse the FLIP bag within the anal canal/vagina even at rest. At larger volumes, with each squeeze there was an increase in the bag pressure and reduction in the cross-sectional area, which represents concentric contraction of the muscle. Both rest and squeeze tension increased with the increase in volume in the anal as well as vaginal canal indicating that the external anal sphincter and puborectalis muscles produce more tension when lengthened. FLIP device, which has been used to describe the distensibility of the anal canal can also provide information on the length-tension function of the anal sphincters and PRM. NEW & NOTEWORTHY The functional luminal imaging probe (FLIP) has been used to describe the distensibility of the anal canal. This report is the first to describe the use of the FLIP in the vaginal canal and the anal canal to provide information on the length-tension function of the anal sphincter and puborectalis muscles, which may provide clinicians with additional information regarding the active components of muscle contraction involved in the anal closure function.
Collapse
Affiliation(s)
- Lori J. Tuttle
- 1Doctor of Physical Therapy Program, School of Exercise and Nutritional Sciences, San Diego State University, San Diego, California
| | - Ali Zifan
- 2Division of Gastroenterology, Department of Medicine, University of California, San Diego, California
| | - Catherine Sun
- 2Division of Gastroenterology, Department of Medicine, University of California, San Diego, California
| | - Jessica Swartz
- 1Doctor of Physical Therapy Program, School of Exercise and Nutritional Sciences, San Diego State University, San Diego, California
| | - Sophia Roalkvam
- 2Division of Gastroenterology, Department of Medicine, University of California, San Diego, California
| | - Ravinder K. Mittal
- 2Division of Gastroenterology, Department of Medicine, University of California, San Diego, California
| |
Collapse
|
8
|
Rajasekaran MR, Kanoo S, Fu J, Nguyen MUL, Bhargava V, Mittal RK. Age-related external anal sphincter muscle dysfunction and fibrosis: possible role of Wnt/β-catenin signaling pathways. Am J Physiol Gastrointest Liver Physiol 2017; 313:G581-G588. [PMID: 28838987 DOI: 10.1152/ajpgi.00209.2017] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2017] [Revised: 08/02/2017] [Accepted: 08/15/2017] [Indexed: 01/31/2023]
Abstract
Studies show an age-related increase in the prevalence of anal incontinence and sphincter muscle atrophy. The Wnt/β-catenin signaling pathway has been recently recognized as the major molecular pathway involved in age-related skeletal muscle atrophy and fibrosis. The goals of our study were to 1) evaluate the impact of normal aging on external anal sphincter (EAS) muscle length-tension (L-T) function and morphology and 2) specifically examine the role of Wnt signaling pathways in anal sphincter muscle fibrosis. New Zealand White female rabbits [6 young (6 mo of age) and 6 old (36 mo of age)] were anesthetized, and anal canal pressure was measured to determine the L-T function of EAS. Animals were killed at the end of the study, and the anal canal was harvested and processed for histochemical studies (Masson trichrome stain for muscle/connective tissue) as well as for molecular markers for fibrosis and atrophy [collagen I, β-catenin, transforming growth factor-β (TGF-β), atrogin-1, and muscle-specific RING finger protein-1 (MuRF-1)]. The L-T was significantly impaired in older animals compared with young animals. Anal canal sections stained with trichrome showed a significant decrease in the muscle content (52% in old compared with 70% in young) and an increase in the connective tissue/collagen content in the old animals. An increased protein and mRNA expression of all the fibrosis markers was seen in the older animals. Aging EAS muscle exhibits impairment of function and increase in connective tissue. Upregulation of atrophy and profibrogenic proteins with aging may be the reason for the age-related decrease in anal sphincter muscle thickness and function.NEW & NOTEWORTHY Our studies using a female rabbit model show age-related alterations in the structure and function of the external anal sphincter (EAS) muscle. We used endoluminal ultrasound to measure age-related changes in EAS muscle thickness. We employed Western blot and quantitative PCR to demonstrate age-related changes in the levels of important fibrogenic as well as atrophy markers. Our findings may have significant clinical implications, i.e., use of specific antagonists to prevent age-related EAS muscle dysfunction.
Collapse
Affiliation(s)
- M Raj Rajasekaran
- Division of Gastroenterology, Department of Medicine, Veterans Affairs San Diego Healthcare System and University of California, San Diego, California; .,Department of Urology, Veterans Affairs San Diego Healthcare System and University of California, San Diego, California; and
| | - Sadhana Kanoo
- Division of Gastroenterology, Department of Medicine, Veterans Affairs San Diego Healthcare System and University of California, San Diego, California
| | - Johnny Fu
- Division of Gastroenterology, Department of Medicine, Veterans Affairs San Diego Healthcare System and University of California, San Diego, California
| | - My-Uyen Lilly Nguyen
- Division of Gastroenterology, Department of Medicine, Veterans Affairs San Diego Healthcare System and University of California, San Diego, California
| | - Valmik Bhargava
- Division of Cardiology, Veterans Affairs San Diego Healthcare System and University of California, San Diego, California
| | - Ravinder K Mittal
- Division of Gastroenterology, Department of Medicine, Veterans Affairs San Diego Healthcare System and University of California, San Diego, California
| |
Collapse
|
9
|
Rajasekaran MR, Kanoo S, Fu J, Bhargava V, Mittal RK. Wnt-β Catenin Signaling Pathway: A Major Player in the Injury Induced Fibrosis and Dysfunction of the External Anal Sphincter. Sci Rep 2017; 7:963. [PMID: 28424479 PMCID: PMC5430485 DOI: 10.1038/s41598-017-01131-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2016] [Accepted: 03/23/2017] [Indexed: 12/19/2022] Open
Abstract
Wnt-β catenin is an important signaling pathway in the genesis of fibrosis in many organ systems. Our goal was to examine the role of Wnt pathway in the external anal sphincter (EAS) injury-related fibrosis and muscle dysfunction. New Zealand White female rabbits were subjected to surgical EAS myotomy and administered local injections of either a Wnt antagonist (sFRP-2; daily for 7 days) or saline. Anal canal pressure and EAS length-tension (L-T) were measured for 15 weeks after which the animals were sacrificed. Anal canal was harvested and processed for histochemical studies (Masson trichrome stain), molecular markers of fibrosis (collagen and transforming growth factor-β) and immunostaining for β catenin. Surgical myotomy of the EAS resulted in significant impairment in anal canal pressure and EAS muscle L-T function. Following myotomy, the EAS muscle was replaced with fibrous tissue. Immunostaining revealed β catenin activation and molecular studies revealed 1.5–2 fold increase in the levels of markers of fibrosis. Local injection of sFRP-2 attenuated the β catenin activation and fibrosis. EAS muscle content and function was significantly improved following sFRP-2 treatment. Our studies suggest that upregulation of Wnt signaling is an important molecular mechanism of injury related EAS muscle fibrosis and sphincter dysfunction.
Collapse
Affiliation(s)
- M Raj Rajasekaran
- Department of Medicine, Division of Gastroenterology, San Diego VA Health Care System & University of California, San Diego, CA, USA.
| | - Sadhana Kanoo
- Department of Medicine, Division of Gastroenterology, San Diego VA Health Care System & University of California, San Diego, CA, USA
| | - Johnny Fu
- Department of Medicine, Division of Gastroenterology, San Diego VA Health Care System & University of California, San Diego, CA, USA
| | - Valmik Bhargava
- Department of Medicine, Division of Gastroenterology, San Diego VA Health Care System & University of California, San Diego, CA, USA
| | - Ravinder K Mittal
- Department of Medicine, Division of Gastroenterology, San Diego VA Health Care System & University of California, San Diego, CA, USA
| |
Collapse
|
10
|
Ratto C, Donisi L, Litta F, Campennì P, Parello A. Implantation of SphinKeeper(TM): a new artificial anal sphincter. Tech Coloproctol 2015; 20:59-66. [PMID: 26658726 PMCID: PMC4751162 DOI: 10.1007/s10151-015-1396-0] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/03/2015] [Accepted: 10/30/2015] [Indexed: 12/17/2022]
Abstract
Introduction A new artificial anal sphincter, SphinKeeperTM, was devised with the aim to treat fecal incontinence (FI) by implanting specifically designed self-expandable prostheses into the intersphincteric space. Preliminary data concerning the procedure feasibility and prosthesis localization at 3 months are presented. Methods SphinKeeperTM prostheses in the native state are dehydrated, thin, solid cylinder (length 29 mm, diameter 3 mm), changing their state (shorter—length 23 mm, thicker—diameter 7 mm—and softer, with shape memory) within 48 h of contact with fluids. In this study, 10 prostheses were implanted in each patient with FI under local anesthesia and under endoanal ultrasound (EAUS) guidance, into the upper-middle intersphincteric space of the anal canal by a specifically designed delivery system. EAUS was used postoperatively to assess prostheses dislocation. Results Ten patients (5 females; median age 58 years, range 20–75) were enrolled and treated with SphinKeeperTM implantation. Median duration of procedure (performed by endoanal ultrasound guidance) was 40 min (range 30–45). Neither intraoperative nor postoperative complications were reported after a 3-month follow-up. In one patient, a partial dislocation of a single prosthesis was documented by EAUS, causing anal discomfort which resolved after 1 week. Conclusion SphinKeeperTM can be safely implanted in patients with FI of different etiology. Implantation was well tolerated with no dislodgment of implants at 3-month follow-up.
Collapse
Affiliation(s)
- C Ratto
- Proctology Unit, Department of Surgical Sciences, Catholic University, Largo A. Gemelli, 8, 00168, Rome, Italy.
| | - L Donisi
- Proctology Unit, Department of Surgical Sciences, Catholic University, Largo A. Gemelli, 8, 00168, Rome, Italy
| | - F Litta
- Proctology Unit, Department of Surgical Sciences, Catholic University, Largo A. Gemelli, 8, 00168, Rome, Italy
| | - P Campennì
- Proctology Unit, Department of Surgical Sciences, Catholic University, Largo A. Gemelli, 8, 00168, Rome, Italy
| | - A Parello
- Proctology Unit, Department of Surgical Sciences, Catholic University, Largo A. Gemelli, 8, 00168, Rome, Italy
| |
Collapse
|
11
|
Mittal RK, Sheean G, Padda BS, Rajasekaran MR. Length tension function of puborectalis muscle: implications for the treatment of fecal incontinence and pelvic floor disorders. J Neurogastroenterol Motil 2014; 20:539-46. [PMID: 25273124 PMCID: PMC4204420 DOI: 10.5056/jnm14033] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2014] [Revised: 04/25/2014] [Accepted: 04/26/2014] [Indexed: 11/20/2022] Open
Abstract
BACKGROUND/AIMS External anal sphincter (EAS) and puborectalis muscle (PRM) play important role in anal continence function. Based on length-tension measurement, we recently reported that the human EAS muscle operates at short sarcomere length under phys-iological conditions. Goal of our study was to determine if PRM also operates at the short sarcomere length. METHODS Length-tension relationship of the PRM muscle was studied in vivo in 10 healthy nullipara women. Length was altered by vagi-nal distension using custom-designed probes of 5, 10, 15, 20, 25 and 30 mm diameters as well as by distending a poly-ethylene bag with different volumes of water. Probes were equipped with a reverse perfuse sleeve sensor to measure vaginal pressure (surrogate of PRM tension). PRM electromyogram (EMG) was recorded using wire electrodes. Three-dimensional ultra-sound images were obtained to determine effect of vaginal distension on PRM length. RESULTS Ultrasound images demonstrate distension volume dependent increase in PRM length. Rest and squeeze pressures of vaginal bag increased with the increase in bag volume. Similarly, the change in vaginal pressure, which represents the PRM contraction increased with the increase in the probe size. Increase in probe size was not associated with an increase in EMG activity (a marker of neural drive) of the PRM. CONCLUSIONS Probe size dependent increase in PRM contraction pressure, in the presence of constant EMG (neural input) proves that the hu-man PRM operates at short sarcomere length. Surgically adjusting the PRM length may represent a novel strategy to improve treat anal continence and possibly other pelvic floor disorders.(J Neurogastroenterol Motil 2014;20:539-546).
Collapse
Affiliation(s)
- Ravinder K Mittal
- Pelvic Floor Function and Diseases Group, Division of Gastroenterology, University of California, San Diego, CA, USA
| | - Geoff Sheean
- Pelvic Floor Function and Diseases Group, Department of Neurology, University of California, San Diego, CA, USA
| | - Bikram S Padda
- Pelvic Floor Function and Diseases Group, Division of Gastroenterology, University of California, San Diego, CA, USA
| | - Mahadevan R Rajasekaran
- Pelvic Floor Function and Diseases Group, Division of Gastroenterology, University of California, San Diego, CA, USA
| |
Collapse
|
12
|
Rajasekaran MR, Sinha S, Seo Y, Salehi M, Bhargava V, Mittal RK. Myoarchitectural and functional alterations in rabbit external anal sphincter muscle following experimental surgical trauma. Am J Physiol Gastrointest Liver Physiol 2014; 307:G445-51. [PMID: 24994856 DOI: 10.1152/ajpgi.00450.2013] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Obstetrical trauma to external anal sphincter (EAS) is extremely common; however, its role in the development of anal incontinence is not clear. We examined the regenerative process and functional impact of experimental surgical trauma to EAS muscle in an animal model. Surgical myotomy, a craniocaudal incision extending along the entire length and thickness of the EAS, was performed in rabbits. Animals were allowed to recover, and anal pressures were recorded at weekly intervals for 12 wk using a custom-designed probe system to determine the length-tension property of EAS muscle. Animals were killed at predetermined time intervals, and the anal canal was harvested for histochemical studies (for determination of muscle/connective tissue/collagen) and sarcomere length measurement. In addition, magnetic resonance diffusion tensor imaging (MR-DTI) and fiber tracking was performed to determine myoarchitectural changes in the EAS. Myotomy of the EAS muscle resulted in significant impairment of its length-tension property that showed only partial recovery during the 12-wk study period. Histology revealed marked increase in the fibrosis (connective tissue = 69% following myotomy vs. 28% in controls) at 3 wk, which persisted at 12 wk. Immunostaining studies confirmed deposition of collagen in the fibrotic tissue. There was no change in the sarcomere length following myotomy. MR-DTI studies revealed disorganized muscle fiber orientation in the regenerating muscle. We conclude that, following experimental injury, the EAS muscle heals with an increase in the collagen content and loss of normal myoarchitecture, which we suspect is the cause of impaired EAS function.
Collapse
Affiliation(s)
- M Raj Rajasekaran
- Division of Gastroenterology, Department of Medicine, San Diego Veterans Affairs Health Care System; and
| | - Shantanu Sinha
- Muscle Imaging and Modeling Laboratory, Department of Radiology, University of California, San Diego, California
| | - Youngjin Seo
- Division of Gastroenterology, Department of Medicine, San Diego Veterans Affairs Health Care System; and
| | - Mitra Salehi
- Division of Gastroenterology, Department of Medicine, San Diego Veterans Affairs Health Care System; and
| | - Valmik Bhargava
- Division of Gastroenterology, Department of Medicine, San Diego Veterans Affairs Health Care System; and
| | - Ravinder K Mittal
- Division of Gastroenterology, Department of Medicine, San Diego Veterans Affairs Health Care System; and
| |
Collapse
|
13
|
Kim YS, Weinstein M, Raizada V, Jiang Y, Bhargava V, Rajasekaran MR, Mittal RK. Anatomical disruption and length-tension dysfunction of anal sphincter complex muscles in women with fecal incontinence. Dis Colon Rectum 2013; 56:1282-9. [PMID: 24105004 PMCID: PMC3802525 DOI: 10.1097/dcr.0b013e3182a18e87] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
BACKGROUND Anal sphincter complex muscles, the internal anal sphincter, external anal sphincter, and puborectalis muscles, play an important role in the anal continence mechanism. Patients with symptoms of fecal incontinence have weak anal sphincter complex muscles; however, their length-tension properties and relationship to anatomical disruption have never been studied. OBJECTIVE This study aimed to assess the anatomy of the anal sphincter complex muscles with the use of a 3-dimensional ultrasound imaging system and to determine the relationship between the anatomical defects and the length-tension property of external anal sphincter and puborectalis muscles in women with incontinence symptoms and in control subjects. DESIGN Severity of anal sphincter muscle damage was determined by static and dynamic 3-dimensional ultrasound imaging. The length-tension property was determined by anal and vaginal pressure with the use of custom-designed probes. PATIENTS Forty-four asymptomatic controls and 24 incontinent patients participated in this study. MAIN OUTCOME MEASURES The anatomical defects and length-tension dysfunction of anal sphincter complex muscles in patients with fecal incontinence were evaluated. RESULTS The prevalence of injury to sphincter muscles is significantly greater in the incontinent patients than in the controls. Eighty-five percent of patients but only 9% controls reveal damage to ≥2 of the 3 muscles of the anal sphincter complex. Anal and vaginal squeeze pressures increased with the increase in the probe size (length-tension curve) in the majority of controls. In patients, the increase in anal and vaginal squeeze pressures was either significantly smaller than in controls or it decreased with the increasing probe size (abnormal length-tension). LIMITATIONS We studied patients with severe symptoms. Whether our findings are applicable to patients with mild to moderate symptoms remains to be determined. CONCLUSIONS The length-tension property of the external anal sphincter and puborectalis muscles is significantly impaired in incontinent patients. Our findings have therapeutic implications for the treatment of anal incontinence.
Collapse
Affiliation(s)
- Young Sun Kim
- 1 Department of Medicine, Division of Gastroenterology, San Diego VA Health Care System & University of California, San Diego, California 2 Department of Internal Medicine, Seoul National University Hospital Healthcare System Gangnam Center, Seoul, South Korea
| | | | | | | | | | | | | |
Collapse
|
14
|
Abstract
Up to 80% of patients with rectal cancer undergo sphincter-preserving surgery. It is widely accepted that up to 90% of such patients will subsequently have a change in bowel habit, ranging from increased bowel frequency to faecal incontinence or evacuatory dysfunction. This wide spectrum of symptoms after resection and reconstruction of the rectum has been termed anterior resection syndrome. Currently, no precise definition or causal mechanisms have been established. This disordered bowel function has a substantial negative effect on quality of life. Previous reviews have mainly focused on different colonic reconstructive configurations and their comparative effects on daily function and quality of life. The present Review explores the potential mechanisms underlying disturbed functions, as well as current, novel, and future treatment options.
Collapse
Affiliation(s)
- Catherine L C Bryant
- Academic Surgical Unit, Barts and The London School of Medicine & Dentistry, Queen Mary University of London, London, UK
| | | | | | | | | |
Collapse
|