1
|
Nakayama LF, Zago Ribeiro L, de Oliveira JAE, de Matos JCRG, Mitchell WG, Malerbi FK, Celi LA, Regatieri CVS. Fairness and generalizability of OCT normative databases: a comparative analysis. Int J Retina Vitreous 2023; 9:48. [PMID: 37605208 PMCID: PMC10440930 DOI: 10.1186/s40942-023-00459-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Accepted: 03/26/2023] [Indexed: 08/23/2023] Open
Abstract
PURPOSE In supervised Machine Learning algorithms, labels and reports are important in model development. To provide a normality assessment, the OCT has an in-built normative database that provides a color base scale from the measurement database comparison. This article aims to evaluate and compare normative databases of different OCT machines, analyzing patient demographic, contrast inclusion and exclusion criteria, diversity index, and statistical approach to assess their fairness and generalizability. METHODS Data were retrieved from Cirrus, Avanti, Spectralis, and Triton's FDA-approval and equipment manual. The following variables were compared: number of eyes and patients, inclusion and exclusion criteria, statistical approach, sex, race and ethnicity, age, participant country, and diversity index. RESULTS Avanti OCT has the largest normative database (640 eyes). In every database, the inclusion and exclusion criteria were similar, including adult patients and excluding pathological eyes. Spectralis has the largest White (79.7%) proportionately representation, Cirrus has the largest Asian (24%), and Triton has the largest Black (22%) patient representation. In all databases, the statistical analysis applied was Regression models. The sex diversity index is similar in all datasets, and comparable to the ten most populous contries. Avanti dataset has the highest diversity index in terms of race, followed by Cirrus, Triton, and Spectralis. CONCLUSION In all analyzed databases, the data framework is static, with limited upgrade options and lacking normative databases for new modules. As a result, caution in OCT normality interpretation is warranted. To address these limitations, there is a need for more diverse, representative, and open-access datasets that take into account patient demographics, especially considering the development of supervised Machine Learning algorithms in healthcare.
Collapse
Affiliation(s)
- Luis Filipe Nakayama
- Laboratory of Computational Physiology, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA, 02139, United States of America.
- Department of Ophthalmology, São Paulo Federal University, Sao Paulo, SP, Brazil.
| | - Lucas Zago Ribeiro
- Department of Ophthalmology, São Paulo Federal University, Sao Paulo, SP, Brazil
| | | | - João Carlos Ramos Gonçalves de Matos
- Laboratory of Computational Physiology, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA, 02139, United States of America
- University of Porto, Porto, Portugal
| | | | | | - Leo Anthony Celi
- Laboratory of Computational Physiology, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA, 02139, United States of America
- Department of Biostatistics, United States of America, Harvard TH Chan School of Public Health, Boston, MA, United States of America
- Department of Medicine, Beth Israel Deaconess Medical Center, Boston, MA, United States of America
| | | |
Collapse
|
2
|
El-Nimri NW, Moghimi S, Nishida T, Yarmohammadi A, Zangwill LM, Hou H, Proudfoot J, Walker E, Fazio MA, Girkin CA, Liebmann JM, Weinreb RN. Racial Differences in Detection of Glaucoma Using Retinal Nerve Fiber Layer Thickness and Bruch Membrane Opening Minimum Rim Width. Am J Ophthalmol 2023; 246:223-235. [PMID: 36662535 DOI: 10.1016/j.ajo.2022.10.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 10/13/2022] [Accepted: 10/15/2022] [Indexed: 02/01/2023]
Abstract
PURPOSE To compare the sensitivities and specificities of the retinal nerve fiber layer thickness (RNFLT) and Bruch membrane opening minimum rim width (BMO-MRW) reference database-based criteria for detection of glaucoma in individuals of European descent (ED) and individuals of African descent (AD). DESIGN Comparative diagnostic analysis by race METHODS: 382 eyes of 255 glaucoma patients (ED = 170, AD = 85) and 94 eyes of 50 healthy individuals (ED = 30, AD = 20) with global and sectoral RNFLT and BMO-MRW measured with Spectralis optical coherence tomography (OCT) were included. Six diagnostic criteria were evaluated: global measurement below the 5th or 1st percentile, ≥1 of the 6 sector measurements below the 5th or 1st percentile, and superotemporal (ST) and/or inferotemporal (IT) measurement below the 5th or 1st percentile. The sensitivities and specificities of these measurements for detection of glaucoma were compared using bootstrapping methods. RESULTS ST and/or IT RNFLT below the 5th percentile has the best performance for detection of glaucoma among RNFLT classifications with a sensitivity (95% CI) of 89.5% (86.1, 92.5) and specificity of 87.2% (77.8, 95.1). In AD individuals, sensitivities of ST and IT RNFLT and BMO-MRW measurements below the 5th percentile criteria were lower than in ED individuals (RNFLT: 83.7% vs 92.5%, and BMO-MRW: 72.1% vs 88.5%, respectively), as well as specificities (AD RNFLT: 73.7% and BMO-MRW: 89.5% vs ED RNFLT: 96.4% and BMO-MRW: 98.2%, respectively). CONCLUSIONS RNFLT and BMO-MRW had consistently lower diagnostic performance in AD individuals compared with ED individuals. BMO-MRW criteria might fail to detect as many as one-third of eyes with glaucoma, specifically in AD individuals. With the current reference database, RNFLT, and especially BMO-MRW, criteria are not adequate for diagnosing glaucoma in AD individuals.
Collapse
Affiliation(s)
- Nevin W El-Nimri
- From the Hamilton Glaucoma Center, Shiley Eye Institute, and the Viterbi Family Department of Ophthalmology, University of California San Diego, La Jolla, California (N.W.E.-N., S.M., T.N., A.Y., L.M.Z., H.H., J.P., E.W., R.N.W.)
| | - Sasan Moghimi
- From the Hamilton Glaucoma Center, Shiley Eye Institute, and the Viterbi Family Department of Ophthalmology, University of California San Diego, La Jolla, California (N.W.E.-N., S.M., T.N., A.Y., L.M.Z., H.H., J.P., E.W., R.N.W.).
| | - Takashi Nishida
- From the Hamilton Glaucoma Center, Shiley Eye Institute, and the Viterbi Family Department of Ophthalmology, University of California San Diego, La Jolla, California (N.W.E.-N., S.M., T.N., A.Y., L.M.Z., H.H., J.P., E.W., R.N.W.)
| | - Adeleh Yarmohammadi
- From the Hamilton Glaucoma Center, Shiley Eye Institute, and the Viterbi Family Department of Ophthalmology, University of California San Diego, La Jolla, California (N.W.E.-N., S.M., T.N., A.Y., L.M.Z., H.H., J.P., E.W., R.N.W.)
| | - Linda M Zangwill
- From the Hamilton Glaucoma Center, Shiley Eye Institute, and the Viterbi Family Department of Ophthalmology, University of California San Diego, La Jolla, California (N.W.E.-N., S.M., T.N., A.Y., L.M.Z., H.H., J.P., E.W., R.N.W.)
| | - Huiyuan Hou
- From the Hamilton Glaucoma Center, Shiley Eye Institute, and the Viterbi Family Department of Ophthalmology, University of California San Diego, La Jolla, California (N.W.E.-N., S.M., T.N., A.Y., L.M.Z., H.H., J.P., E.W., R.N.W.)
| | - James Proudfoot
- From the Hamilton Glaucoma Center, Shiley Eye Institute, and the Viterbi Family Department of Ophthalmology, University of California San Diego, La Jolla, California (N.W.E.-N., S.M., T.N., A.Y., L.M.Z., H.H., J.P., E.W., R.N.W.)
| | - Evan Walker
- From the Hamilton Glaucoma Center, Shiley Eye Institute, and the Viterbi Family Department of Ophthalmology, University of California San Diego, La Jolla, California (N.W.E.-N., S.M., T.N., A.Y., L.M.Z., H.H., J.P., E.W., R.N.W.)
| | - Massimo A Fazio
- Department of Ophthalmology and Visual Sciences, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama (M.A.F., C.A.G.) and
| | - Christopher A Girkin
- Department of Ophthalmology and Visual Sciences, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama (M.A.F., C.A.G.) and
| | - Jeffrey M Liebmann
- Bernard and Shirlee Brown Glaucoma Research Laboratory, Department of Ophthalmology, Edward S. Harkness Eye Institute, Columbia University Irving Medical Center, New York, New York (J.M.L.), USA
| | - Robert N Weinreb
- From the Hamilton Glaucoma Center, Shiley Eye Institute, and the Viterbi Family Department of Ophthalmology, University of California San Diego, La Jolla, California (N.W.E.-N., S.M., T.N., A.Y., L.M.Z., H.H., J.P., E.W., R.N.W.)
| |
Collapse
|
3
|
A Myopic Normative Database for Retinal Nerve Fiber Layer Thickness using Optical Coherence Tomography. J Glaucoma 2022; 31:816-825. [PMID: 35882029 DOI: 10.1097/ijg.0000000000002084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Accepted: 07/07/2022] [Indexed: 11/26/2022]
Abstract
PRCIS The purpose of this study was to determine changes in OCT color codes after applying a myopic normative database. The diagnostic performance of the retinal nerve fiber layer analysis improved with the use of this database. PURPOSE To evaluate the pRNFL color codes based on a newly generated myopic normative database in comparison to the built-in normative database. METHODS A total of 371 subjects were included in this validation study in an attempt to generate a myopic normative database. Eighty myopic glaucomatous and 80 myopic healthy eyes were evaluated to determine the diagnostic performance of this database. The distribution of the color codes was investigated among the groups with reference to the built-in and myopic normative databases, and the two databases were compared in terms of abnormal color code frequency. The diagnostic performance of the myopic database was presented with sensitivity, specificity and area under the receiver operating characteristics curve (AUROC) values. RESULTS The agreement between the databases decreased with increasing myopia degree. The distribution of the color codes of the built-in software significantly differed among the study groups in all sectors (P=0.009 for the temporal sector and P<0.001 for the remaining sectors). When the myopic database was used, there were no longer significant differences among the groups for the temporosuperior, temporoinferior, temporal and nasal sectors (P=0.561, 0.299, 0.201, and 0.089 respectively). After applying the myopic normative database, the specificity of the pRNFL color codes increased from 70.1% to 90.2%, and the AUROC value from 0.851 to 0.945. CONCLUSIONS The use of a myopic normative database for pRNFL using SD-OCT significantly decreased differences among myopia severity groups, and may help to more reliably assess glaucoma in myopic eyes.
Collapse
|
4
|
Wu J, Du Y, Lin C, Zhu Y, Chen W, Pan Q, Zhuo Y, Wang N. Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study. Br J Ophthalmol 2022:bjophthalmol-2021-320618. [PMID: 35383049 PMCID: PMC10359552 DOI: 10.1136/bjophthalmol-2021-320618] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Accepted: 03/13/2022] [Indexed: 12/17/2022]
Abstract
PURPOSE To examine the normative profile of retinal nerve fibre layer (RNFL) thickness and ocular parameters based on spectral-domain optical coherence tomography (SD-OCT) and its associations with related parameters among the Chinese population. METHODS This population-based cohort Handan Eye Study (HES) recruited participants aged≥30 years. All subjects underwent a standardised ophthalmic examination. Peripapillary RNFL thickness was obtained using SD-OCT. Mixed linear models were adopted to evaluate the correlation of RNFL thickness with ocular parameters as well as systemic factors. R V.3.6.1 software was used for statistical analysis. RESULTS 3509 subjects (7024 eyes) with the average age of 55.54±10.37 were collected in this analysis. Overall mean RNFL thickness measured was 113.46±10.90 µm, and the thickest quadrant of parapapillary RNFL was the inferior quadrant, followed by the superior quadrant, the nasal quadrant and the temporal quadrant. In the multivariate linear regression model, thinner RNFL thickness was remarkable association with male (p<0.001), older age (p<0.001), increased body mass index (>30, p=0.018), absence of diabetes (p=0.009), history of cataract surgery (p=0.001), higher intraocular pressure (p=0.007), lower spherical equivalent (p<0.001) and increased axial length (p=0.048). CONCLUSIONS In non-glaucoma individuals, this difference of RNFL thickness in Chinese population should be noted in making disease diagnoses. Meanwhile, multiple ocular and systemic factors are closely related to the thickness of RNFL. Our findings further emphasise the need to demonstrate ethnic differences in RNFL thickness and the specificity of associated ocular and systemic factors, as well as to develop better normative databases worldwide. TRIAL REGISTRATION NUMBER HES was registered in Chinese Clinical Trial Registry website, and the registry number was ChiCTR-EOC-17013214.
Collapse
Affiliation(s)
- Jian Wu
- Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, China.,Department of Ophthalmology, Stanford University School of Medicine, Palo Alto, California, USA
| | - Yifan Du
- Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, China
| | - Caixia Lin
- Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, China
| | - Yingting Zhu
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Wei Chen
- Department of Ophthalmology, Stanford University School of Medicine, Palo Alto, California, USA
| | - Qing Pan
- Department of Epidemiology and Biostatistics, West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Yehong Zhuo
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Ningli Wang
- Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, China
| |
Collapse
|
5
|
Addis V, Chan L, Chen J, Goodyear K, Pistilli M, Salowe R, Lee R, Sankar P, Miller-Ellis E, Cui QN, Maguire MG, O’Brien J. Evaluation of the Cirrus High-Definition OCT Normative Database Probability Codes in a Black American Population. Ophthalmol Glaucoma 2022; 5:110-118. [PMID: 34033949 PMCID: PMC8608902 DOI: 10.1016/j.ogla.2021.05.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 04/26/2021] [Accepted: 05/17/2021] [Indexed: 02/06/2023]
Abstract
PURPOSE Race-adjusted interpretation of data from Cirrus high-definition OCT (HD-OCT) devices is not standard practice. The aim of this study is to evaluate differences in peripapillary retinal nerve fiber layer (RNFL) thickness between healthy Black Americans and the Cirrus HD-OCT normative database. DESIGN This is a cross-sectional observational study using control patients recruited from the greater Philadelphia, Pennsylvania, area. PARTICIPANTS A total of 466 eyes were included in this study. Subjects were retrospectively identified from the control cohort of the Primary Open-Angle African American Glaucoma Genetics (POAAGG) study. METHODS Using an age-stratified or linear regression method, we reclassified white-green-yellow-red color probability codes for RNFL thicknesses by quadrant. MAIN OUTCOME MEASURES The distribution of reclassified color codes was compared with the expected 5%-90%-4%-1% percentiles and to the original color codes by the Cirrus machine. RESULTS Average RNFL thickness in the POAAGG control cohort was thinner than in the Cirrus normative database in all except the nasal quadrant. The original color codes of the POAAGG cohort did not fall into the expected distributions, with more RNFL measurements assigned as white and red codes than expected (9.5% and 1.7%) and fewer measurements assigned as green and yellow codes than expected (85.3% and 3.5%) (P < 0.001). Compared with the original Cirrus machine, reclassification using linear regression produced color codes closest to the expected distributions (P = 0.09). The proportion of abnormal results shifted closer to the expected 5% in the nasal (1.3%, P < 0.001 vs. 3.0%, P = 0.048) and temporal (8.2%, P = 0.002 vs. 3.6%, P = 0.18) quadrants. CONCLUSIONS Results further establish the presence of structural differences in the RNFL of Black American patients. Color code reclassification suggests that the existing Cirrus database may not be accurately evaluating glaucomatous nerves in patients of African descent. This study addresses an unmet need to assess Cirrus HD-OCT color probability codes in a Black American population.
Collapse
Affiliation(s)
- Victoria Addis
- Scheie Eye Institute, University of Pennsylvania,
Philadelphia, PA, USA
| | - Lilian Chan
- Scheie Eye Institute, University of Pennsylvania,
Philadelphia, PA, USA
| | - Judy Chen
- Scheie Eye Institute, University of Pennsylvania,
Philadelphia, PA, USA
| | - Kendall Goodyear
- Scheie Eye Institute, University of Pennsylvania,
Philadelphia, PA, USA
| | - Maxwell Pistilli
- Scheie Eye Institute, University of Pennsylvania,
Philadelphia, PA, USA
| | - Rebecca Salowe
- Scheie Eye Institute, University of Pennsylvania,
Philadelphia, PA, USA
| | - Roy Lee
- Scheie Eye Institute, University of Pennsylvania,
Philadelphia, PA, USA
| | - Prithvi Sankar
- Scheie Eye Institute, University of Pennsylvania,
Philadelphia, PA, USA
| | | | - Qi N. Cui
- Scheie Eye Institute, University of Pennsylvania,
Philadelphia, PA, USA
| | | | - Joan O’Brien
- Scheie Eye Institute, University of Pennsylvania,
Philadelphia, PA, USA.,Corresponding Author: Scheie Eye Institute,
51 N. 39th Street, Philadelphia, PA 19104, USA,
(; phone: 215-662-8657; fax:
215-662-9676)
| |
Collapse
|
6
|
Paulsen AJ, Pinto A, Merten N, Chen Y, Fischer ME, Huang GH, Klein BEK, Schubert CR, Cruickshanks KJ. Factors Associated with the Macular Ganglion Cell-Inner Plexiform Layer Thickness in a Cohort of Middle-aged U.S. Adults. Optom Vis Sci 2021; 98:295-305. [PMID: 33771958 PMCID: PMC8007043 DOI: 10.1097/opx.0000000000001650] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
Abstract
SIGNIFICANCE The macular ganglion cell-inner plexiform layer (mGCIPL) may serve as a quick and easily obtained measure of generalized neurodegeneration. Investigating factors associated with this thickness could help to understand neurodegenerative processes. PURPOSE This study aimed to characterize and identify associated factors of the mGCIPL thickness in a Beaver Dam Offspring Study cohort of middle-aged U.S. adults. METHODS Baseline examinations occurred from 2005 to 2008, with follow-up examinations every 5 years. Included participants had baseline data and measured mGCIPL at 10-year follow-up (N = 1848). The mGCIPL was measured using the Cirrus 5000 HD-OCT Macular Cube Scan. Associations between mean mGCIPL thickness and thin mGCIPL, defined as 1 standard deviation (SD) below the population mean, and baseline risk factors were investigated using generalized estimating equations. RESULTS Participants (mean [SD] baseline age, 48.9 [9.3] years; 54.4% women) had mean (SD) mGCIPL thicknesses of 78.4 (8.1) μm in the right eye and 78.1 (8.5) μm in the left (correlation coefficient = 0.76). In multivariable models, age (-1.07 μm per 5 years; 95% confidence interval [CI], -1.28 to -0.86 μm), high alcohol consumption (-1.44 μm; 95% CI, -2.72 to -0.16 μm), higher interleukin 6 levels (50% increase in level: -0.23 μm; 95% CI, -0.45 to 0.00 μm), myopia (-2.55 μm; 95% CI, -3.17 to -1.94 μm), and glaucoma (-1.74 μm; 95% CI, -2.77 to -0.70 μm) were associated with thinner mGCIPL. Age (per 5 years: odds ratio [OR], 1.38; 95% CI, 1.24 to 1.53), diabetes (OR, 1.89, 95% CI, 1.09 to 3.27), myopia (OR, 2.11; 95% CI, 1.63 to 2.73), and increasing and long-term high C-reactive protein (ORs, 1.46 [95% CI, 1.01 to 2.11] and 1.74 [95% CI, 1.14 to 2.65], respectively) were associated with increased odds of thin mGCIPL. CONCLUSIONS Factors associated cross-sectionally with mGCIPL thickness, older age, high alcohol consumption, inflammation, diabetes, myopia, and glaucoma may be important to neural retina structure and health and neuronal health system-wide.
Collapse
Affiliation(s)
| | - Alex Pinto
- Department of Ophthalmology and Visual Sciences, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin
| | - Natascha Merten
- Department of Population Health Sciences, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin
| | - Yanjun Chen
- Department of Ophthalmology and Visual Sciences, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin
| | - Mary E Fischer
- Department of Ophthalmology and Visual Sciences, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin
| | | | - Barbara E K Klein
- Department of Ophthalmology and Visual Sciences, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin
| | - Carla R Schubert
- Department of Ophthalmology and Visual Sciences, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin
| | | |
Collapse
|
7
|
Thakur S, Yu M, Tham YC, Majithia S, Soh ZD, Fang XL, Cheung C, Boey PY, Aung T, Wong TY, Cheng CY. Utilisation of poor-quality optical coherence tomography scans: adjustment algorithm from the Singapore Epidemiology of Eye Diseases (SEED) study. Br J Ophthalmol 2021; 106:962-969. [PMID: 33589436 DOI: 10.1136/bjophthalmol-2020-317756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Revised: 12/27/2020] [Accepted: 01/29/2021] [Indexed: 11/03/2022]
Abstract
PURPOSE To evaluate the effect of signal strength (SS) on optical coherence tomography (OCT) parameters, and devise an algorithm to adjust the effect, when acceptable SS cannot be obtained. METHODS 5085 individuals (9582 eyes), aged ≥40 years from the Singapore Epidemiology of Eye Diseases population-based study were included. Everyone underwent a standardised ocular examination and imaging with Cirrus HD-OCT. Effect of SS was evaluated using multiple structural breaks linear mixed-effect models. Expected change for increment in SS between 4 and 10 for individual parameter was calculated. Subsequently we devised and evaluated an algorithm to adjust OCT parameters to higher SS. RESULTS Average retinal nerve fibre layer (RNFL) thickness showed shift of 4.11 µm from SS of 5 to 6. Above 6, it increased by 1.72 and 3.35 µm to 7 and 8; and by 1.09 µm (per unit increase) above 8 SS. Average ganglion cell-inner plexiform layer (GCIPL) thickness shifted 5.15 µm from SS of 5 to 6. Above 6, increased by 0.94 µm from 7 to 8; and by 0.16 µm (per unit increase) above 8 SS. When compared with reference in an independent test set, the algorithm produced less systemic bias. Algorithm-adjusted average RNFL was 0.549 µm thinner than the reference, while the unadjusted one was 2.841 µm thinner (p<0.001). Algorithm-adjusted and unadjusted average GCIPL was 1.102 µm and 2.228 µm thinner (p<0.001). CONCLUSIONS OCT parameters can be adjusted for poor SS using an algorithm. This can potentially assist in diagnosis and monitoring of glaucoma when scans with acceptable SS cannot be acquired from patients in clinics.
Collapse
Affiliation(s)
| | - Marco Yu
- Singapore Eye Research Institute, Singapore
| | - Yih Chung Tham
- Singapore Eye Research Institute, Singapore
- Singapore National Eye Centre, Singapore
- Ophthalmology & Visual Sciences Academic Clinical Program (Eye ACP), Duke-NUS Medical School, Singapore
| | | | - Zhi-Da Soh
- Singapore Eye Research Institute, Singapore
| | - Xiao Ling Fang
- Singapore Eye Research Institute, Singapore
- Department of Ophthalmology, Shanghai Eye Diseases Prevention & Treatment Center/ Shanghai Eye Hospital, Shanghai, China
| | - Carol Cheung
- Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong, Hong Kong
| | - Pui Yi Boey
- Singapore National Eye Centre, Singapore
- Ophthalmology & Visual Sciences Academic Clinical Program (Eye ACP), Duke-NUS Medical School, Singapore
| | - Tin Aung
- Singapore Eye Research Institute, Singapore
- Singapore National Eye Centre, Singapore
- Ophthalmology & Visual Sciences Academic Clinical Program (Eye ACP), Duke-NUS Medical School, Singapore
- Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | - Tien Yin Wong
- Singapore Eye Research Institute, Singapore
- Singapore National Eye Centre, Singapore
- Ophthalmology & Visual Sciences Academic Clinical Program (Eye ACP), Duke-NUS Medical School, Singapore
- Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | - Ching-Yu Cheng
- Singapore Eye Research Institute, Singapore
- Singapore National Eye Centre, Singapore
- Ophthalmology & Visual Sciences Academic Clinical Program (Eye ACP), Duke-NUS Medical School, Singapore
- Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| |
Collapse
|
8
|
Perez CI, Chansangpetch S, Mora M, Nguyen A, Zhao J, Han Y, Lin SC. Ethnicity-Specific Database Improves the Diagnostic Ability of Peripapillary Retinal Nerve Fiber Layer Thickness to Detect Glaucoma. Am J Ophthalmol 2021; 221:311-322. [PMID: 32777372 DOI: 10.1016/j.ajo.2020.07.043] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2019] [Revised: 07/06/2020] [Accepted: 07/30/2020] [Indexed: 11/16/2022]
Abstract
PURPOSE To determine the changes in optical coherence tomography (OCT) color probability codes and diagnostic ability for peripapillary retinal nerve fiber layer (pRNFL) and ganglion cell complex (GCC) analysis after applying Chinese and white subjects normative databases. DESIGN Cross-sectional study. METHODS This study enrolled 219 healthy eyes (108 white and 111 Chinese patients) to construct an ethnicity-specific normative database for pRNFL and macular GCC thickness, which was tested then in 180 eyes with or without glaucoma (102 white and 78 Chinese patients). The percent of change of color probability codes were evaluated after applying the original built-in and the ethnicity-specific normative databases, respectively. Sensitivity and specificity were calculated to evaluate the change in diagnostic ability to detect glaucoma. RESULTS Healthy white subjects had a thinner pRNFL than Chinese subjects in the overall average thickness as well as the superior, inferior, and temporal quadrants (P < .001). Macular GCC did not differ between ethnicities. After applying an ethnicity-specific normative database, the percent of pRNFL abnormal color code labels decreased significantly for the overall average thickness in the white subjects. This resulted in a significant increase in the specificity to detect glaucoma in the white population (P < .001). No significant changes were seen when applying an ethnicity-specific normative database for macular GCC thickness. CONCLUSIONS After applying an ethnicity-specific normative database, the percent of pRNFL abnormal color codes decreased significantly, improving the specificity to detect glaucoma in the white population. These findings suggest there may be utility in having ethnicity-specific normative databases for pRNFL thickness.
Collapse
Affiliation(s)
- Claudio I Perez
- Department of Ophthalmology, University of California, San Francisco, San Francisco, California, USA; Fundación Oftalmológica Los Andes, Universidad de los Andes, Santiago, Chile.
| | - Sunee Chansangpetch
- Department of Ophthalmology, University of California, San Francisco, San Francisco, California, USA; Faculty of Medicine, Chulalongkorn University, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand
| | - Marta Mora
- Department of Ophthalmology, University of California, San Francisco, San Francisco, California, USA
| | - Anwell Nguyen
- Department of Ophthalmology, University of California, San Francisco, San Francisco, California, USA
| | - Jing Zhao
- Department of Ophthalmology, University of California, San Francisco, San Francisco, California, USA; Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Key Laboratory of Ophthalmology and Visual Sciences, Beijing, China
| | - Ying Han
- Department of Ophthalmology, University of California, San Francisco, San Francisco, California, USA
| | - Shan C Lin
- Department of Ophthalmology, University of California, San Francisco, San Francisco, California, USA; Glaucoma Center of San Francisco, San Francisco, California, USA
| |
Collapse
|
9
|
Tham YC, Chee ML, Dai W, Lim ZW, Majithia S, Siantar R, Thakur S, Rim T, Cheung CY, Sabanayagam C, Aung T, Wong TY, Cheng CY. Profiles of Ganglion Cell-Inner Plexiform Layer Thickness in a Multi-Ethnic Asian Population: The Singapore Epidemiology of Eye Diseases Study. Ophthalmology 2020; 127:1064-1076. [PMID: 32197910 DOI: 10.1016/j.ophtha.2020.01.055] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2019] [Revised: 12/31/2019] [Accepted: 01/30/2020] [Indexed: 02/07/2023] Open
Abstract
PURPOSE To examine the normative profile and determinants of macular ganglion cell-inner plexiform layer (GCIPL) thickness based on spectral-domain OCT (SD-OCT) in a nonglaucoma, multi-ethnic Asian population. DESIGN Population-based, cross-sectional study. PARTICIPANTS Ethnic Chinese, Malay, and Indian adults aged ≥40 years recruited from the Singapore Epidemiology of Eye Diseases Study. METHODS All participants underwent standardized examinations. The GCIPL thickness was measured using Cirrus HD-OCT (Carl Zeiss Meditec, Dublin, CA). Participants with glaucoma or poor-quality scans were excluded. Eye-specific data were used. Associations of ocular and systemic factors with GCIPL thickness parameters were investigated using multivariable linear regression with generalized estimating equation models to account for correlation between both eyes. MAIN OUTCOME MEASURES GCIPL thickness. RESULTS A total of 4464 participants (7520 eyes) consisting of 1625 Chinese, 1212 Malay, and 1627 Indian adults contributed to this analysis. Average GCIPL thickness was 82.6±6.1 μm in Chinese, 81.5±6.8 μm in Malays, and 78.0±6.9 μm in Indians (P < 0.001 by analysis of variance). The 5th percentile limit of average GCIPL thickness was 72 μm in Chinese, 70 μm in Malays, and 67 μm in Indians. In multivariable analysis adjusting for age, gender, axial length, presence of cataract, OCT signal strength, disc area, hypertension, diabetes, and hyperlipidemia, eyes of Indians were observed to have 3.43 μm thinner GCIPL on average compared with Chinese (P < 0.001) and 3.36 μm thinner GCIPL compared with Malays (P < 0.001). In addition, older age (per decade; β = -2.51), female (β = -1.57), longer axial length (per mm; β = -1.54), and presence of chronic kidney disease (β = -1.49) were significantly associated with thinner average GCIPL (all P ≤ 0.008). Larger optic disc area (per mm2; β = 0.78; P < 0.001) was associated with thicker GCIPL. These factors were consistently observed to be significant for superior and inferior hemisphere GCIPL thickness. CONCLUSIONS GCIPL thickness profiles were significantly thinner in Indians compared with Chinese and Malays. Our findings further highlight the need of a more refined, ethnic-specific normative database for GCIPL thickness, which in turn may improve the detection and diagnosis of glaucoma in Asians.
Collapse
Affiliation(s)
- Yih-Chung Tham
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore; Ophthalmology and Visual Sciences Academic Clinical Program (Eye ACP), Duke-NUS Medical School, Singapore
| | - Miao Li Chee
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
| | - Wei Dai
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
| | - Zhi Wei Lim
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
| | - Shivani Majithia
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
| | | | - Sahil Thakur
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
| | - Tyler Rim
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore; Ophthalmology and Visual Sciences Academic Clinical Program (Eye ACP), Duke-NUS Medical School, Singapore
| | - Carol Y Cheung
- Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong
| | - Charumathi Sabanayagam
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore; Ophthalmology and Visual Sciences Academic Clinical Program (Eye ACP), Duke-NUS Medical School, Singapore
| | - Tin Aung
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore; Ophthalmology and Visual Sciences Academic Clinical Program (Eye ACP), Duke-NUS Medical School, Singapore; Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | - Tien Yin Wong
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore; Ophthalmology and Visual Sciences Academic Clinical Program (Eye ACP), Duke-NUS Medical School, Singapore; Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | - Ching-Yu Cheng
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore; Ophthalmology and Visual Sciences Academic Clinical Program (Eye ACP), Duke-NUS Medical School, Singapore; Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore.
| |
Collapse
|
10
|
Yoo YJ, Hwang JM, Yang HK. Inner macular layer thickness by spectral domain optical coherence tomography in children and adults: a hospital-based study. Br J Ophthalmol 2019; 103:1576-1583. [DOI: 10.1136/bjophthalmol-2018-312349] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2018] [Revised: 12/02/2018] [Accepted: 12/19/2018] [Indexed: 12/19/2022]
Abstract
PurposeTo establish the normative ranges of macular ganglion cell layer (mGCL) and macular inner plexiform layer (mIPL) thickness using Spectralis spectral domain optical coherence tomography (SD-OCT) (Heidelberg Engineering, Inc., Heidelberg, Germany) in both Korean children and adults, and to determine factors associated with mGCL and mIPL thickness.MethodsWe conducted a retrospective, observational study of 573 healthy subjects (5–70 years old) who underwent comprehensive ophthalmic examinations in a single institution. Each inner retinal layer thickness was measured using SD-OCT and automatic segmentation software. Cross-sectional analysis was used to evaluate the effect of gender, age and ocular parameters on mGCL and mIPL thickness. Normative ranges of mGCL and mIPL thickness according to age, gender and factors associated with mGCL and mIPL thickness were measured.ResultsThe mean mGCL and mIPL thickness were 40.6±2.8 and 33.8±2.0 µm, respectively. Determinants of inner sector mGCL thickness were circumpapillary retinal nerve fibre layer (cpRNFL) thickness (β=1.172, p<0.001), age (β=−0.019, p=0.021) and male gender (β=1.452, p<0.001). Determinants of inner sector mIPL thickness were cpRNFL (β=0.952, p<0.001) and male gender (β=1.163, p<0.001). The inner sector mGCL and mIPL thickness increased significantly with age in children (β=0.174, p=0.009 and β=0.115, p=0.013), and then decreased in adults (β=−0.070, p<0.001 and β=−0.024, p=0.032). In the case of outer sectors, mGCL and mIPL thickness were not significantly related to age and gender.ConclusionsThis study ensured a normative range of the mGCL and mIPL thickness using Spectralis OCT. Gender, age and cpRNFL thickness significantly correlated with mGCL and mIPL thickness. This information should be considered in the interpretation of SD-OCT data.
Collapse
|