1
|
Nilforushan N, Yousefi M, Babic A, Gharehbaghi A. Clinical Validation of M-TONX: A Novel Combo Rebound Tonometer and Pachymeter. Transl Vis Sci Technol 2024; 13:34. [PMID: 39723679 DOI: 10.1167/tvst.13.12.34] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2024] Open
Abstract
Purpose This study aims to perform a clinical investigation of an innovative rebound technology-based device, the M-TONX, to simultaneously measure intraocular pressure (IOP) and central corneal thickness (CCT). Methods The IOP and CCT of the patients were first measured by the M-TONX. Then, the measurements were repeated by the Goldman applanation (GAT) and the Pentacam corneal topographer, as the standard devices. For the statistical analysis, the patients were stratified based on their IOPs to group 1 (IOP < = 16 millimeters of mercury [mm Hg]), group 2 (16 mm Hg < IOP < 23 mm Hg), and group 3 (IOP > = 23 mm Hg). The stratification was also performed for the CCTs as: class 1 (CCT < = 475 µm), class 2 (475 < CCT < 574 µm), and class 3 (CCT > = 575 µm). Results Of the 374 eyes (225 subjects and 43% women), 262, 66, and 46 eyes belonged to group 1, group 2, and group 3, respectively. Very high IOP (>35 mm Hg) was observed in 12 eyes. The overall confidence interval of the deviation (confidence level = 95%) from the standard devices was estimated to be 0.7 to 1.2 mm Hg for IOP, and -12.7 to -5.4 µm for CCT. The stratified analysis showed substantial agreement with the standard devices with the intraclass correlation > 0.65 and the Pearson Correlation > 0.8 calculated for all the groups and classes. Conclusions The M-TONX exhibited a reliable performance concerning the standards for measuring IOP and CCT. Its accuracy remains stable for a broad range of IOP and CCT. The M-TONX successfully incorporates two separate functionalities into a single compact user-friendly device. Translational Relevance This study uncovers the conformity of the technology with the standards, linking fundamental research to clinical care.
Collapse
Affiliation(s)
| | | | - Ankica Babic
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
- Department of Information Sciences and Media Studies, University of Bergen, Bergen, Norway
| | - Arash Gharehbaghi
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| |
Collapse
|
2
|
Sachdeva R, Iordanous Y, Lin T. Comparison of intraocular pressure measured by iCare tonometers and Goldmann applanation tonometer. CANADIAN JOURNAL OF OPHTHALMOLOGY 2023; 58:426-432. [PMID: 35809628 DOI: 10.1016/j.jcjo.2022.06.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Revised: 05/31/2022] [Accepted: 06/07/2022] [Indexed: 11/21/2022]
Abstract
OBJECTIVE To evaluate the relationship between the Goldmann applanation tonometer (GAT) and the iCare PRO and iCare IC200 tonometers in measuring intraocular pressure (IOP) in adult eyes with a diagnosis of glaucoma or glaucoma suspect. PARTICIPANTS AND METHODS One hundred and one eyes from 101 participants diagnosed with glaucoma or glaucoma suspect were evaluated in this study. IOP was measured by iCare PRO and iCare IC200 tonometers in a randomized sequence followed by IOP measurements by the GAT tonometer and then central corneal thickness measurements. After the IOP measurements, participants scored their comfort level using a visual analog scale with each tonometer. Intraclass correlation coefficient (ICC) and Bland-Altman analysis were used to investigate the agreement among tonometers. SPSS and Microsoft Excel programs were used for statistical analysis. RESULTS Overall, there was good agreement among the 3 tonometers used in this study. The ICC for the iCare PRO and the iCare IC200 was 0.95 (p < 0.001), and the ICC for the iCare PRO and the GAT and the iCare IC200 and the GAT was >0.80 (p < 0.001). However, both iCare tonometers underestimated IOP by approximately 2 mm Hg compared with the GAT. Furthermore, 84% of iCare readings fall within ±5 mm Hg of GAT measurements. Neither body mass index nor central corneal thickness affected the IOP agreement among the tonometers. Participant response on visual analog scale rated IOP measurements by iCare tonometers to be more comfortable than the GAT. CONCLUSION Our results demonstrated a good agreement between iCare tonometers and GAT; but iCare tonometers underestimated IOP compared to the GAT.
Collapse
Affiliation(s)
| | | | - Tony Lin
- Department of Ophthalmology, Western University, London, Ont
| |
Collapse
|
3
|
De Bernardo M, Pilone V, Di Paola I, Cione F, Cembalo G, Calabrese P, Rosa N. Intraocular Pressure Variations in Postural Changes: Comparison between Obese and Non-Obese Controls. J Clin Med 2023; 12:5883. [PMID: 37762825 PMCID: PMC10531973 DOI: 10.3390/jcm12185883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 08/31/2023] [Accepted: 09/07/2023] [Indexed: 09/29/2023] Open
Abstract
BACKGROUND Comparing intraocular pressure (IOP) changes (ΔIOP) between obese subjects and non-obese controls in relation to different positions: standing, sitting, supine. METHODS the IOP was measured in both obese patients and non-obese controls groups with Tono-Pen AVIA in different positions following this sequence: after 5 min (5') in the standing position, sitting, supine, supine after 5 min (supine 5') and immediately after standing. ΔIOP values obtained comparing all positions were, therefore, evaluated. RESULTS 92 eyes of 46 obese subjects aged between 18 and 59 years (mean 38.07 ± 11.51 years) and of a Body Mass Index (BMI) between 31.84 and 60.65 (mean 41.84 ± 7.05) were evaluated. A total of 48 eyes of 24 non-obese controls aged between 23 and 55 (mean 35.21 ± 11.96 years) and of a BMI between 18.20 and 26.79 (mean 21.04 ± 2.36) were also recruited. In obese subjects, there were statistically significant differences between the IOP in the supine position and the supine positions 5' with all other IOP measurements (p < 0.05). There were statistically significant differences between ΔIOP in both supine positions and prolonged standing positions obtained by obese subjects and non-obese controls (p < 0.05). CONCLUSIONS In obese subjects, there is a statistically significant increase in IOP in the supine positions that is significantly greater than the non-obese population. BMI is weakly correlated with IOP and ΔIOP in postural changes.
Collapse
Affiliation(s)
- Maddalena De Bernardo
- Eye Unit, Department of Medicine, Surgery and Dentistry, Scuola Medica Salernitana, University of Salerno, 84084 Salerno, Italy; (M.D.B.); (N.R.)
| | - Vincenzo Pilone
- Unit of General, Emergency and Bariatric Surgery, Department of Medicine, Surgery and Dentistry, Scuola Medica Salernitana, University of Salerno, 84084 Salerno, Italy; (V.P.)
| | - Ilenia Di Paola
- Eye Unit, Department of Medicine, Surgery and Dentistry, Scuola Medica Salernitana, University of Salerno, 84084 Salerno, Italy; (M.D.B.); (N.R.)
| | - Ferdinando Cione
- Eye Unit, Department of Medicine, Surgery and Dentistry, Scuola Medica Salernitana, University of Salerno, 84084 Salerno, Italy; (M.D.B.); (N.R.)
| | - Giovanni Cembalo
- Eye Unit, Department of Medicine, Surgery and Dentistry, Scuola Medica Salernitana, University of Salerno, 84084 Salerno, Italy; (M.D.B.); (N.R.)
| | - Pietro Calabrese
- Unit of General, Emergency and Bariatric Surgery, Department of Medicine, Surgery and Dentistry, Scuola Medica Salernitana, University of Salerno, 84084 Salerno, Italy; (V.P.)
| | - Nicola Rosa
- Eye Unit, Department of Medicine, Surgery and Dentistry, Scuola Medica Salernitana, University of Salerno, 84084 Salerno, Italy; (M.D.B.); (N.R.)
| |
Collapse
|
4
|
Wong PPY, Tsim NC, Chan KKW, Lau IHW, Mak ACY, Chen GLJ, Iu LPL, Ho M, Young AL, Brelén M. Rise in intraocular pressure with elevator travel in post-vitrectomy patients. Sci Rep 2023; 13:14088. [PMID: 37640777 PMCID: PMC10462696 DOI: 10.1038/s41598-023-40416-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Accepted: 08/09/2023] [Indexed: 08/31/2023] Open
Abstract
To evaluate the impact of elevator travel on intraocular pressure after vitreoretinal surgery with gas tamponade. Patients undergoing pars plana vitreoretinal surgery with and without gas insertion were recruited on post-operative day 1. All intraocular pressures were measured three times by Tono-Pen AVIA (Reichert, USA) on the fourth floor and, after rapid ascent in an elevator, on the 12th floor of the hospital. All patients were observed and asked for any symptoms of pain or nausea for at least 15 min. In this study, 54 patients were recruited. Twenty-seven patients underwent vitreoretinal procedures with gas insertion, while 27 patients without gas insertion acted as controls. The mean age of patients was 60.9 years. The mean changes in intraocular pressure of the patients with gas insertion (+ 1.39 mmHg) were greater than those without gas insertion (- 0.43 mmHg) and statistically significantly different (95% CI 1.17-2.48, P < 0.0001). Patients undergoing vitreoretinal surgery with gas insertion had statistically significant intraocular pressure rise even with 8-floor ascent in the immediate post-operative period. Further studies are needed to evaluate the change in intraocular pressure with a larger range of altitudes and different gases.
Collapse
Affiliation(s)
- Posey P Y Wong
- Department of Ophthalmology and Visual Sciences, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, Hong Kong
| | - Nicole C Tsim
- Department of Ophthalmology and Visual Sciences, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, Hong Kong
| | - Karen K W Chan
- Department of Ophthalmology and Visual Sciences, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, Hong Kong
| | - Ivan H W Lau
- Department of Ophthalmology and Visual Sciences, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, Hong Kong
| | - Andrew C Y Mak
- Department of Ophthalmology and Visual Sciences, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, Hong Kong
| | - Guy L J Chen
- Department of Ophthalmology and Visual Sciences, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, Hong Kong
- Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, 4/F Hong Kong Eye Hospital, 147K Argyle Street, Kowloon, Hong Kong
| | - Lawrence P L Iu
- Department of Ophthalmology and Visual Sciences, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, Hong Kong
| | - Mary Ho
- Department of Ophthalmology and Visual Sciences, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, Hong Kong
| | - Alvin L Young
- Department of Ophthalmology and Visual Sciences, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, Hong Kong
| | - Mårten Brelén
- Department of Ophthalmology and Visual Sciences, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, Hong Kong.
- Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, 4/F Hong Kong Eye Hospital, 147K Argyle Street, Kowloon, Hong Kong.
| |
Collapse
|
5
|
Gui H, Zhang Y, Chang RT, Wang SY. Real-world agreement of same-visit Tono-Pen vs Goldmann applanation intraocular pressure measurements using electronic health records. Heliyon 2023; 9:e18703. [PMID: 37576221 PMCID: PMC10412763 DOI: 10.1016/j.heliyon.2023.e18703] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 06/26/2023] [Accepted: 07/25/2023] [Indexed: 08/15/2023] Open
Abstract
Purpose To compare intraocular pressure (IOP) obtained with Tono-Pen (TP) and Goldmann applanation (GAT) using large-scale electronic health records (EHR). Design Retrospective cohort study. Methods A single pair of eligible TP/GAT IOP readings was randomly selected from the EHR for each ophthalmology patient at an academic ophthalmology center (2013-2022), yielding 4550 eligible measurements. We used Bland-Altman analysis to describe agreement between TP/GAT IOP differences and mean IOP measurements. We also used multivariable logistic regression to identify factors associated with different IOP readings in the same eye, including demographics, glaucoma diagnosis, and central corneal thickness (CCT). Primary outcome metrics were discrepant measurements between TP and GAT as defined by two methods: Outcome A (normal TP despite elevated GAT measurements), and Outcome B (TP and GAT IOP differences ≥6 mmHg). Result The mean TP/GAT IOP difference was 0.15 mmHg ( ± 5.49 mmHg 95% CI). There was high correlation between the measurements (r = 0.790, p < 0.001). We found that TP overestimated pressures at IOP <16.5 mmHg and underestimated at IOP >16.5 mmHg (Fig. 4). Discrepant measurements accounted for 2.6% (N = 116) and 5.2% (N = 238) for outcomes A and B respectively. Patients with thinner CCT had higher odds of discrepant IOP (OR 0.88 per 25 μm increase, CI [0.84-0.92], p < 0.0001; OR 0.88 per 25 μm increase, CI [0.84-0.92], p < 0.0001 for outcomes A and B respectively). Conclusion In a real-world academic practice setting, TP and GAT IOP measurements demonstrated close agreement, although 2.6% of measurements showed elevated GAT IOP despite normal TP measurements, and 5.2% of measurements were ≥6 mmHg apart.
Collapse
Affiliation(s)
- Haiwen Gui
- Stanford University School of Medicine, Stanford, United States
| | - Youchen Zhang
- Byers Eye Institute, Department of Ophthalmology, Stanford University, Palo Alto, United States
| | - Robert T. Chang
- Byers Eye Institute, Department of Ophthalmology, Stanford University, Palo Alto, United States
| | - Sophia Y. Wang
- Byers Eye Institute, Department of Ophthalmology, Stanford University, Palo Alto, United States
| |
Collapse
|
6
|
Lee YF, Chay J, Husain R, Wong TT, Ho CL, Lamoureux EL, Chew ACY. Three-year Outcomes of an Expanded Asynchronous Virtual Glaucoma Clinic in Singapore. Asia Pac J Ophthalmol (Phila) 2023; 12:364-369. [PMID: 37523427 DOI: 10.1097/apo.0000000000000620] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Accepted: 05/11/2023] [Indexed: 08/02/2023] Open
Abstract
PURPOSE Virtual glaucoma clinics can help increase health care capacity, easing the disease burden of glaucoma. This study assesses the safety, rate of glaucoma progression, time efficiency, and cost-savings of our expanded Glaucoma Observation Clinic (GLOC) at the Singapore National Eye Centre over 3 years. METHODS All patients seen at GLOC between July 2018 and June 2021 were included. Visual acuity, intraocular pressure, and visual fields or optic nerve head imaging were recorded, followed by a virtual review of the data by an ophthalmologist. An objective review of the management of 100 patients was conducted by 2 senior consultants independently as a safety audit. Patient outcomes including the rate of instability (due to worsening of clinical parameters necessitating a conventional clinic visit), glaucoma progression, the consultation review time efficiency, and cost-savings of GLOC were measured. RESULTS Of 3458 patients, 16% had glaucoma, and the others had risk factors for glaucoma. The safety audit demonstrated a 95% interobserver agreement. The rate of instability was 14.6%, of which true progression was observed in 3.12%. The time taken for a glaucoma specialist to review a GLOC patient was 5.75±0.75 minutes compared with 13.7±2.3 minutes in a conventional clinic. The per capita manpower cost per GLOC patient per visit was $36.77 compared with $65.62 in the conventional clinic. This translates to a cost-saving of $280.65 over the lifetime of a hypothetical patient. CONCLUSIONS Our expanded virtual glaucoma clinic is a safe, time-efficient, and cost-effective model with low rates of glaucoma progression, which could allow for significant health care capacity expansion.
Collapse
Affiliation(s)
- Yi Fang Lee
- Glaucoma Service, Singapore National Eye Centre, Singapore
- Singapore Eye Research Institute, Singapore
- Duke-NUS Medical School, Singapore
| | - Junxing Chay
- Health Services and Systems Research, Duke-NUS Medical School, Singapore
| | - Rahat Husain
- Glaucoma Service, Singapore National Eye Centre, Singapore
- Singapore Eye Research Institute, Singapore
- Duke-NUS Medical School, Singapore
| | - Tina T Wong
- Glaucoma Service, Singapore National Eye Centre, Singapore
- Singapore Eye Research Institute, Singapore
- Duke-NUS Medical School, Singapore
| | - Ching Lin Ho
- Glaucoma Service, Singapore National Eye Centre, Singapore
- Singapore Eye Research Institute, Singapore
- Duke-NUS Medical School, Singapore
| | - Ecosse L Lamoureux
- Glaucoma Service, Singapore National Eye Centre, Singapore
- Singapore Eye Research Institute, Singapore
- Duke-NUS Medical School, Singapore
- Health Services and Systems Research, Duke-NUS Medical School, Singapore
| | - Annabel C Y Chew
- Glaucoma Service, Singapore National Eye Centre, Singapore
- Singapore Eye Research Institute, Singapore
- Duke-NUS Medical School, Singapore
| |
Collapse
|
7
|
Soares PHA, Santos RDO, Filho CRADM, Neto SPM, Junior JAP. Goldmann Applanation Tonometry: Comparison of Intraocular Pressure Values Obtained with Disposable Tip and Conventional Applanation Prism in the Population without Clinical Signs of Glaucoma. J Curr Glaucoma Pract 2023; 17:75-78. [PMID: 37485456 PMCID: PMC10357021 DOI: 10.5005/jp-journals-10078-1401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Accepted: 01/27/2023] [Indexed: 07/25/2023] Open
Abstract
Aim Comparing intraocular pressure (IOP) measurements using Goldmann applanation prism and TonoSafe® in the population without signs of glaucoma. Material and methods Patients with no ocular pathologies, except ametropia (until ± 4 D) or IOP of <30 mm Hg without signs of glaucoma by optic disc structural analysis by fundus biomicroscopy. The IOP was measured sequentially using the traditional cone and the TonoSafe®, according to a randomization list to determine which device would be used first. The measurements from the right and left eyes were compared separately. Since there was no statistical difference, both eyes were considered in this study. Results A total of 385 eyes of 194 patients with a mean age of 66.4 ± 11.2 years old were included. The mean IOP with conventional prism was 14.2 ± 3.6 and 14.3 ± 3.6 mm Hg with TonoSafe®. Differences were not statistically significant by the Wilcoxon test (p = 0.3). The median was 14.0 mm Hg for both groups. The mean difference between measurements was 0.04 mm Hg, with the median equal to zero. There was no statistical difference in IOP readings according to which device was the first measurement. Conclusion No statistical difference was found in IOP was measured with conventional prism or TonoSafe® in the population without signs of glaucoma. Clinical significance The data provided by our study support the efficacy and safety of the disposable tonometer compared to the Goldman tonometer in measuring IOP in patients without glaucoma. How to cite this article Soares PHA, Santos RDO, Filho CRADM, et al. Goldmann Applanation Tonometry: Comparison of Intraocular Pressure Values Obtained with Disposable Tip and Conventional Applanation Prism in the Population without Clinical Signs of Glaucoma. J Curr Glaucoma Pract 2023;17(2):75-78.
Collapse
Affiliation(s)
- Pedro Henrique Alves Soares
- Department of Ophthalmology, Health Science Institute, Federal University of Triângulo Mineiro, Uberaba, Minas Gerais, Brazil
| | - Rafael de Oliveira Santos
- Department of Ophthalmology, Health Science Institute, Federal University of Triângulo Mineiro, Uberaba, Minas Gerais, Brazil
| | | | - Sebastião Pimenta Moraes Neto
- Department of Ophthalmology, Health Science Institute, Federal University of Triângulo Mineiro, Uberaba, Minas Gerais, Brazil
| | - João Antonio Prata Junior
- Department of Ophthalmology, Health Science Institute, Federal University of Triângulo Mineiro, Uberaba, Minas Gerais, Brazil
| |
Collapse
|
8
|
Keller WJ. International comparisons of intraocular pressures, as measured by Tono-Pen and Goldmann applanation tonometry, in healthy adults: A meta-analysis. Medicine (Baltimore) 2023; 102:e33078. [PMID: 36897721 PMCID: PMC9997780 DOI: 10.1097/md.0000000000033078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2023] [Accepted: 02/02/2023] [Indexed: 03/11/2023] Open
Abstract
BACKGROUND Investigate intraocular pressure (IOP), as measured by Tono-Pen (TP) and Goldmann applanation tonometry (GAT), in healthy adults. Provide an updated synthesis of multinational, primary studies, reported during the 10-year period 2011 to 2021 and offer an evidence-based benchmark, against which IOP can be evaluated across subject variables and pathologies. Three primary research questions are investigated: Is there a statistically significant difference between IOP measured by TP and GAT? If yes, is the difference clinically significant? Is measurement of IOP affected by the country or setting location, in which the measurements are made? METHODS An aggregate meta-analysis was conducted on 22 primary studies, from 15 different countries. IOP measurements were made from each healthy adult subject, with both the TP and GAT. Primary studies were identified and data extracted according to recommended preferred reporting items for systematic reviews and meta-analysis protocol guidelines. Meta-analysis summary results are reported as the point estimate of the raw mean difference of IOP. RESULTS Meta-analysis reveals a statistically significant difference in raw mean differences in IOP, when measured by TP and GAT, in the healthy adult population. Tono-Pen IOP measurements are higher than GAT IOP measurements. The point estimate for the summary effect size = -0.73 mm Hg, P = .03. The prediction interval for the true effect size, in 95% of all comparable populations, is -4.03 to 2.58 mm Hg. There is no clinically significance difference in IOP when measured by TP and GAT. Meta-regression analysis reveals statistically significant differences in measurement of IOP by countries, R2 analog = 0.75, P = .001. There is no statistically significant difference in measurement of IOP as a function of measurement location setting, R2 analog = -0.17, P = .65. CONCLUSIONS IOP measured by TP are marginally higher compared to GAT, in the healthy adult population. However, from a clinical practice perspective, TP and GAT produce similar IOP measurements. There is evidence of significant variabilities in IOP measurements as a function of country. IOP measurements collected in a research laboratory setting are similar to IOP collected in a clinical setting. Results have implications for the primary care physician requiring a portable, inexpensive, reliable, and easily administered instrument to assess IOP.
Collapse
Affiliation(s)
- William J. Keller
- Medical Education, Nova Southeastern University, Kiran C. Patel College of Allopathic Medicine (NSU-MD), Fort Lauderdale, Florida, USA
| |
Collapse
|
9
|
Molero-Senosiain M, Morales-Fernandez L, Saenz-Frances F, Kwan J, Garcia Feijoo J, Martínez-de-la-Casa JM. Analysis of the influence of corneal properties and densitometry on applanation and rebound tonometry in primary open angle glaucoma. J Fr Ophtalmol 2023; 46:249-257. [PMID: 36739259 DOI: 10.1016/j.jfo.2022.08.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 07/30/2022] [Accepted: 08/16/2022] [Indexed: 02/05/2023]
Abstract
PURPOSE To evaluate the influence of corneal densitometry on portable applanation (Perkins) and rebound (iCare ic100 and PRO) tonometry. A secondary goal was to assess if there was a relationship between various corneal properties and the severity of primary open angle glaucoma (POAG). MATERIAL AND METHODS Seventy-five eyes of 75 patients with primary open angle glaucoma were studied, divided by severity into 3 groups: 25 mild, 25 moderate and 25 advanced. Intraocular pressure (IOP) was measured 3 times in each participant with a Perkins applanation tonometer (PAT), a handheld version of the Goldman applanation tonometer (GAT), an iCare PRO and an iCare ic100. Mean values were then calculated. Corneal topography with the Pentacam HR (Oculus, Wetzlar, Germany) was also performed in all individuals. RESULTS Mean age and sex were comparable in all groups, as were densitometry values (P>0.05). The mean visual field defect (MD) was 2.85 (±1.23) dB in the mild glaucoma group, 8.26 (±1.90) dB in the moderate group and 15.66 (±3.46) dB in the advanced group. Three multivariate regression analyses were performed. The first and second calculations assessed the effect of IOP obtained with iCare ic100 and PAT as dependent variables with age, sex, CCT and mean keratometry (Km) within the glaucoma subgroups and the global sample. The third analysis was carried out to assess the relationship between corneal densitometry as the dependant variable and the aforementioned corneal parameters among the glaucoma groups. In the first multivariate regression analysis, a statistically significant correlation was found between ic100 rebound tonometry and CCT in the POAG global sample (coef. 0.117; IC [-0.21-(-0.01)]; P=0.025). No statistically significant correlation was found in the subgroup analyses. In the second multivariate analysis, no significant correlation was found between PAT and CCT, Km, age or sex (P>0.05). In the third analysis, densitometry was correlated with age in all glaucoma subgroups (P<0.001) and with CCT in the moderate glaucoma subgroup (coef. -0.037; IC [-0.67-(-0.01)]; P=0.021). Tonometry appeared to be minimally influenced by corneal densitometry, with a mild positive linear correlation seen (R=0.03). IOP values were similar with 3 of the tonometers: PAT 16.07 (±3.18) mmHg, PRO 16.27 (±3.42) mmHg and ic100 15.17 (±4.28) mmHg. There was, however, a significant underestimation of IOP with ic100 (-0.89mmHg) compared to PAT (P=0.007). CONCLUSION Corneal densitometry did not show significant differences between glaucoma severity groups. A positive correlation was seen with CCT and both corneal densitometry and age. No correlation was found with keratometry or severity of glaucoma. The influence of corneal densitometry on IOP measurements appears weak, with little clinical relevance identified.
Collapse
Affiliation(s)
| | | | | | - J Kwan
- Univeristy Hospitals of Leicester, England, Leicester, United Kingdom
| | | | | |
Collapse
|
10
|
Du B, Wang Q, Luo Y, Jin N, Rong H, Wang X, Nian H, Guo L, Liang M, Wei R. Prediction of spherical equivalent difference before and after cycloplegia in school-age children with machine learning algorithms. Front Public Health 2023; 11:1096330. [PMID: 37113174 PMCID: PMC10126339 DOI: 10.3389/fpubh.2023.1096330] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2022] [Accepted: 03/17/2023] [Indexed: 04/29/2023] Open
Abstract
Purpose To predict the need for cycloplegic assessment, as well as refractive state under cycloplegia, based on non-cycloplegic ocular parameters in school-age children. Design Random cluster sampling. Methods The cross-sectional study was conducted from December 2018 to January 2019. Random cluster sampling was used to select 2,467 students aged 6-18 years. All participants were from primary school, middle school and high school. Visual acuity, optical biometry, intraocular pressure, accommodation lag, gaze deviation in primary position, non-cycloplegic and cycloplegic autorefraction were conducted. A binary classification model and a three-way classification model were established to predict the necessity of cycloplegia and the refractive status, respectively. A regression model was also developed to predict the refractive error using machine learning algorithms. Results The accuracy of the model recognizing requirement of cycloplegia was 68.5-77.0% and the AUC was 0.762-0.833. The model for prediction of SE had performances of R^2 0.889-0.927, MSE 0.250-0.380, MAE 0.372-0.436 and r 0.943-0.963. As the prediction of refractive error status, the accuracy and F1 score was 80.3-81.7% and 0.757-0.775, respectively. There was no statistical difference between the distribution of refractive status predicted by the machine learning models and the one obtained under cycloplegic conditions in school-age students. Conclusion Based on big data acquisition and machine learning techniques, the difference before and after cycloplegia can be effectively predicted in school-age children. This study provides a theoretical basis and supporting evidence for the epidemiological study of myopia and the accurate analysis of vision screening data and optometry services.
Collapse
Affiliation(s)
- Bei Du
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Qingxin Wang
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Yuan Luo
- School of Medical Technology, Tianjin Medical University, Tianjin, China
| | - Nan Jin
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Hua Rong
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Xilian Wang
- Tianjin Beichen Traditional Chinese Medicine Hospital, Tianjin, China
| | - Hong Nian
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Li Guo
- School of Medical Technology, Tianjin Medical University, Tianjin, China
- *Correspondence: Li Guo,
| | - Meng Liang
- School of Medical Technology, Tianjin Medical University, Tianjin, China
- Meng Liang,
| | - Ruihua Wei
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
- Ruihua Wei,
| |
Collapse
|
11
|
Félix H, Oliveira ES. Non-Invasive Intracranial Pressure Monitoring and Its Applicability in Spaceflight. Aerosp Med Hum Perform 2022; 93:517-531. [DOI: 10.3357/amhp.5922.2022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
INTRODUCTION: Neuro-ophthalmic findings collectively defined as Spaceflight-Associated Neuro-ocular Syndrome (SANS) are one of the leading health priorities in astronauts engaging in long duration spaceflight or prolonged microgravity exposure. Though multifactorial in etiology,
similarities to terrestrial idiopathic intracranial hypertension (IIH) suggest these changes may result from an increase or impairing in intracranial pressure (ICP). Finding a portable, accessible, and reliable method of monitoring ICP is, therefore, crucial in long duration spaceflight. A
review of recent literature was conducted on the biomedical literature search engine PubMed using the search term “non-invasive intracranial pressure”. Studies investigating accuracy of noninvasive and portable methods were assessed. The search retrieved different methods that
were subsequently grouped by approach and technique. The majority of publications included the use of ultrasound-based methods with variable accuracies. One of which, noninvasive ICP estimation by optical nerve sheath diameter measurement (nICP_ONSD), presented the highest statistical correlation
and prediction values to invasive ICP, with area under the curve (AUC) ranging from 0.75 to 0.964. One study even considers a combination of ONSD with transcranial Doppler (TCD) for an even higher performance. Other methods, such as near-infrared spectroscopy (NIRS), show positive and promising
results [good statistical correlation with invasive techniques when measuring cerebral perfusion pressure (CPP): r = 0.83]. However, for its accessibility, portability, and accuracy, ONSD seems to present itself as the up to date, most reliable, noninvasive ICP surrogate and a valuable spaceflight
asset.Félix H, Santos Oliveira E. Non-invasive intracranial pressure monitoring and its applicability in spaceflight. Aerosp Med Hum Perform. 2022; 93(6):517–531.
Collapse
|
12
|
Abstract
PURPOSE OF REVIEW The current article reviews enhancements to the delivery of glaucoma care that developed in response to the coronavirus disease 19 (COVID-19) pandemic and are likely to persist beyond its resolution. RECENT FINDINGS Literature from the review period (2020-2021) includes reports highlighting contributions of the ophthalmology community to global health during the pandemic. Glaucoma practices worldwide have instituted more robust infection control measures to mitigate severe acute respiratory syndrome coronavirus 2 transmission in the outpatient setting, and many of these modifications will endure in the post-COVID era. Operational adjustments have led to the provision of more efficient glaucoma care. A hybrid care model involving technician-based diagnostic testing and subsequent virtual consultation with a glaucoma specialist has evolved as a useful adjunct to traditional face-to-face encounters with patients. SUMMARY Glaucoma specialists, patients, and staff have adapted to a 'new normal' of glaucoma care delivery during the COVID-19 pandemic. Although innovation has propelled several improvements to glaucoma care during this global health crisis, significant barriers to more widespread implementation of teleglaucoma still exist. Whether, and in what capacity, the pandemic has permanently altered glaucoma practice patterns remains to be seen.
Collapse
Affiliation(s)
- Kateki Vinod
- Department of Ophthalmology, Icahn School of Medicine at Mount Sinai and New York Eye and Ear Infirmary of Mount Sinai, New York, New York USA
| | | |
Collapse
|
13
|
Liinamaa MJ, Stoor K, Leiviskä I, Saarela V. Correlation of iCare ic100 tonometry with iCare TA01i in screening of unselected population in Northern Finland Birth Cohort Eye study. Eur J Ophthalmol 2021; 32:11206721211014387. [PMID: 33951959 DOI: 10.1177/11206721211014387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE iCare tonometers are easy-to-use and portable devices for measuring the intraocular pressure (IOP). Purpose was to evaluate the IOP values measured by both novel iCare ic100 and conventional model TA01i devices in unselected population. METHODS IOP was measured with iCare ic100 and TA01i tonometers in 149 participants aged 32-33 years (born in 1985 or 1986) of the Northern Finland Birth Cohort Eye 2 study. The right eye of each participant was selected for analysis. We also collected data on axial length, corneal curvature and central corneal thickness (CCT). Bland-Altman plot was used for comparing the values obtained by these devices. RESULTS Mean IOP measured with the ic100 device was 13.8 (3.4) mmHg, with TA01i it was 12.5 (3.0) mmHg. The mean difference between these devices was 1.30 mmHg (p < 0.001) and R2 was 0.694. In Bland-Altman analysis, the agreement between the two tonometers ic100 and TA01i was constantly good (mean difference -1.30, ic100 device showing higher measures). There was a correlation between IOP and CCT (r = 0.269, p < 0.001 for ic100 and r = 0.255, p = 0.002 for TA01i), but not with IOP and corneal curvature or IOP and axial length. CONCLUSION In summary, we found ic100 rebound tonometry to be both reliable and effective, although CCT may influence IOP measurements with ic100 and TA01i. Therefore, iCare ic100 is suitable for IOP measurement in large cohort studies.
Collapse
Affiliation(s)
- M Johanna Liinamaa
- Department of Ophthalmology, Oulu University Hospital, Oulu, Finland
- MRC Oulu, University of Oulu, Oulu, Finland
- PEDEGO Research Unit, University of Oulu, Oulu, Finland
| | - Katri Stoor
- Department of Ophthalmology, Oulu University Hospital, Oulu, Finland
- MRC Oulu, University of Oulu, Oulu, Finland
- PEDEGO Research Unit, University of Oulu, Oulu, Finland
| | - Ilmari Leiviskä
- Department of Ophthalmology, Oulu University Hospital, Oulu, Finland
- MRC Oulu, University of Oulu, Oulu, Finland
- PEDEGO Research Unit, University of Oulu, Oulu, Finland
| | - Ville Saarela
- Department of Ophthalmology, Oulu University Hospital, Oulu, Finland
- MRC Oulu, University of Oulu, Oulu, Finland
- PEDEGO Research Unit, University of Oulu, Oulu, Finland
| |
Collapse
|
14
|
Gillmann K, Wasilewicz R, Hoskens K, Simon-Zoula S, Mansouri K. Continuous 24-hour measurement of intraocular pressure in millimeters of mercury (mmHg) using a novel contact lens sensor: Comparison with pneumatonometry. PLoS One 2021; 16:e0248211. [PMID: 33755676 PMCID: PMC7987168 DOI: 10.1371/journal.pone.0248211] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2020] [Accepted: 02/18/2021] [Indexed: 11/18/2022] Open
Abstract
PURPOSE To address the unmet need of continuous IOP monitoring, a Pressure-Measuring Contact Lens (PMCL) was developed to measure IOP in millimeters of mercury (mmHg) continuously over 24 hours. The present study assessed the reliability of the novel PMCL. METHODS In this prospective open-label clinical study, healthy and open-angle glaucoma (OAG) subjects were fitted with the PMCL, and pneumatonometry was performed on study eyes (in absence of the PMCL) and on fellow eyes before, during, and after provocative tests. The primary outcome measures were (1) mean IOP difference between same-eye measurements, and (2) percentage of timepoints at which IOP measured by the PMCL was within 5 mmHg of that measured by pneumatonometry in the fellow eye. RESULTS Eight subjects were analysed (4 healthy, 4 OAG). The average difference in successive IOP measurements made by pneumatonometry and with the PMCL was 2.0±4.3mmHg at placement-time, and 6.5±15.2mmHg at removal time. During water drinking test, a significant increase in IOP was detected both by PMCL in the study eye (2.4±2.5mmHg, p = 0.03) and by pneumatonometry in the fellow eye (1.9±1.9mmHg, p = 0.02). Over the 24-hour recording, 88.0% of IOP variations measured by the PMCL were within 5mmHg of that measured with the pneumatonometer in the fellow eye. A transient corneal erosion of severe intensity was observed following removal of the PMCL on one single eye, and may have affected measurement accuracy in that eye. CONCLUSIONS This study is a proof-of-concept for this novel PMCL, and its results are encouraging, with a fair accuracy in IOP values measurement and good sensitivity to subtle IOP variations.
Collapse
Affiliation(s)
- Kevin Gillmann
- Glaucoma Research Centre, Montchoisi Clinic, Swiss Visio Network, Lausanne, Switzerland
| | | | - Kirsten Hoskens
- Glaucoma Research Centre, Montchoisi Clinic, Swiss Visio Network, Lausanne, Switzerland
| | | | - Kaweh Mansouri
- Glaucoma Research Centre, Montchoisi Clinic, Swiss Visio Network, Lausanne, Switzerland
- Department of Ophthalmology, University of Colorado School of Medicine, Aurora, Colorado, United States of America
- * E-mail:
| |
Collapse
|
15
|
Blumberg MJ, Varikuti VNV, Weiner A. Real-world comparison between the Tonopen and Goldmann applanation tonometry in a university glaucoma clinic. Int Ophthalmol 2021; 41:1815-1825. [PMID: 33651312 DOI: 10.1007/s10792-021-01742-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Accepted: 02/06/2021] [Indexed: 11/29/2022]
Abstract
PURPOSE To determine whether Tonopen intraocular pressure (IOP) measurements by Ophthalmic technicians are interchangeable with Goldmann applanation tonometry (GAT) by a specialist in our glaucoma clinic. METHODS Ophthalmic technician Tonopen and glaucoma specialist GAT IOP measurements were performed on both undilated eyes of 300 consecutive patients during the same visit to our glaucoma clinic. RESULTS Among all 600 eyes of 300 patients (age 65.4, range: 23-92 years, male: 44.3%), Tonopen and GAT IOPs were similar (15.5 ± 0.6 vs. 15.4 ± 0.7 mmHg, respectively, p = 0.63) and directly correlated (r2 = 0.58, p < 0.0001). However, among 120 patients with bilateral primary open-angle glaucoma GAT IOP was significantly higher than Tonopen in the right eyes (17.1 ± 1.1 vs. 16.2 ± 0.9 mmHg, p = 0.024) and in the left eyes (17.0 ± 1.0 vs. 16.3 ± 1.0 mmHg, p = 0.029). In all 300 right eyes, Tonopen underestimated IOP in 48.3% of eyes and overestimated in 39% (difference range: ( - )14 to ( + )12 mmHg), with IOP difference > ± 3 mmHg in 34% of eyes. In eyes with GAT IOP ≥ 22 mmHg, Tonopen IOP was significantly lower (24.7 ± 2.6, range: 11-43 mmHg vs. 28.2 ± 2.2, range: 22-43 mmHg, p = 0.0002, mean difference: - 3.6 ± 1.7 mmHg), and the Tonopen measured IOP ≤ 21 mmHg in 33.3% of eyes. In eyes with Tonopen IOP ≤ 10 mmHg GAT measured IOP of 11-17 mmHg in 65.7% of eyes. CONCLUSIONS Tonopen may mask a third of eyes with elevated IOP and two third of eyes with potentially above-goal IOP. The Tonopen may not be interchangeable with GAT or sufficiently reliable for patient management or screening in our glaucoma clinic. However, further study is recommended to assess the limitations of the Tonopen IOP measurements in eyes with higher or lower GAT IOPs. CLINICAL TRIALS REGISTRATION The Institutional review board, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY does not require this retrospective study to register.
Collapse
Affiliation(s)
- Max J Blumberg
- Jacobs School of Medicine and Biomedical Sciences, University at Buffalo/State University of New York (SUNY), Buffalo, NY, USA.,Albany Medical Center, PGY-1 Ophthalmology, Albany, NY, USA
| | - Venkata N V Varikuti
- Department of Ophthalmology and Ira G. Ross Eye Institute, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo/State University of New York (SUNY), 1176 Main Street, Buffalo, NY, 14209, USA.,Lexitas Pharma Services, Durham, NC, USA
| | - Asher Weiner
- Department of Ophthalmology and Ira G. Ross Eye Institute, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo/State University of New York (SUNY), 1176 Main Street, Buffalo, NY, 14209, USA.
| |
Collapse
|
16
|
Abstract
PURPOSE OF REVIEW The current article reviews the impact of the coronavirus disease 2019 (COVID-19) pandemic on the delivery of ophthalmic, and specifically, glaucoma care. RECENT FINDINGS Literature from the review period includes case series demonstrating the presence of severe acute respiratory syndrome coronavirus 2 RNA in the conjunctival secretions of patients with laboratory-confirmed COVID-19. The global ophthalmology community published reports outlining the enhanced infection control measures undertaken by different institutions around the world to mitigate transmission of the novel coronavirus. Telemedicine has been increasingly implemented in glaucoma practices to reduce in-office patient volume. New data regarding the efficacy and feasibility of tools for home monitoring of intraocular pressure, virtual visual field testing, and remote disc photography are reviewed. SUMMARY COVID-19 has posed a global public health threat due to the severity of its contagion and associated morbidity and mortality. Glaucoma specialists have responded to the pandemic with innovative modifications to reduce viral transmission and optimize patient and staff safety in the office and operating room. The role of teleglaucoma has expanded and will continue to evolve as remote diagnostic devices undergo further refinement and validation.
Collapse
Affiliation(s)
- Kateki Vinod
- Department of Ophthalmology, Icahn School of Medicine at Mount Sinai
- Department of Ophthalmology, New York Eye and Ear Infirmary of Mount Sinai, New York, New York, USA
| | - Paul A Sidoti
- Department of Ophthalmology, Icahn School of Medicine at Mount Sinai
- Department of Ophthalmology, New York Eye and Ear Infirmary of Mount Sinai, New York, New York, USA
| |
Collapse
|
17
|
Subramaniam AG, Allen P, Toh T. Comparison of the Icare ic100 Rebound Tonometer and the Goldmann Applanation Tonometer in 1,000 Eyes. Ophthalmic Res 2020; 64:321-326. [PMID: 32906125 DOI: 10.1159/000511455] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Accepted: 09/08/2020] [Indexed: 11/19/2022]
Abstract
BACKGROUND Measurement of intraocular pressure (IOP) forms a crucial component in the diagnosis and management of glaucoma. Many devices have been developed to measure IOP with Goldmann applanation tonometry (GAT) considered the gold standard for IOP measurement. OBJECTIVES The objective was to compare the IOP measured using Icare ic100 and GAT. METHODS This cross-sectional study measured IOP in 1,000 eyes (500 left and 500 right) using the Icare ic100 and GAT. Central corneal thickness (CCT) was measured using a hand-held pachymeter. IOP measurements were investigated in all eyes, by IOP substrata, by CCT group, by number of topical glaucoma medications, and diagnosis. RESULTS There was moderate agreement between ic100 and GAT IOP measurements (intraclass correlation coefficient 0.73). Mean IOP was significantly lower when measured by ic100 than by GAT (12.1 vs. 16.2 mm Hg, p < 0.0001). Mean ic100 IOPs were also significantly lower than mean GAT IOPs within each IOP strata ≤12 (7.9 vs. 9.7 mm Hg, p < 0.0001), 13-21 (12.1 vs. 16.6 mm Hg, p < 0.0001), and ≥22 (18.4 vs. 25.2 mm Hg, p < 0.0001) and within each subanalysis. CONCLUSIONS The Icare tonometer consistently under estimated IOP compared to GAT, irrespective of CCT ranges and other subgroup analyses. The mean difference of 4.2 mm Hg can have significant clinical implications, particularly in the management of glaucoma patients.
Collapse
Affiliation(s)
- Arjun Gopal Subramaniam
- Tasmanian Eye Institute, Launceston, Tasmania, Australia.,Launceston Clinical School, College of Health and Medicine, University of Tasmania, Launceston General Hospital, Launceston, Tasmania, Australia
| | - Penelope Allen
- Tasmanian Eye Institute, Launceston, Tasmania, Australia, .,Rural Clinical School, College of Health and Medicine, University of Tasmania, Hospitals' Campus, Burnie, Tasmania, Australia,
| | - Tze'Yo Toh
- Tasmanian Eye Institute, Launceston, Tasmania, Australia
| |
Collapse
|
18
|
Almazyad EM, Ameen S, Khan MA, Malik R. Guidelines and Recommendations for Tonometry Use during the COVID-19 Era. Middle East Afr J Ophthalmol 2020; 27:73-78. [PMID: 32874038 PMCID: PMC7442084 DOI: 10.4103/meajo.meajo_237_20] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2020] [Revised: 06/20/2020] [Accepted: 06/21/2020] [Indexed: 11/10/2022] Open
Abstract
The novel coronavirus disease COVID-19 caused by Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) has resulted in a substantial change in eye care and clinical practice. There has been conflicting information and weak evidence on the virus's transmission through tears. Yet, virus detection on cornea and conjunctiva surface as a gateway for infection is not well-studied. Moreover, there have been no reported cases of SARS-CoV-2 transmission through tonometry to date. Thus, this uncertainty has urged this review on evidence-based guidelines and recommendations on tonometer use in the COVID-19 era. The aim of this article is to provide ophthalmologists with recommendations for tonometry practice based on current evidence and best practice guidelines.
Collapse
Affiliation(s)
- Enmar M. Almazyad
- Research Department, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia
| | - Sally Ameen
- Western Eye Hospital, Imperial NHS Foundation Trust, London, UK
| | - Mohammad A. Khan
- Department of Microbiology, Prince Mohammed Bin Abdul Aziz Hospital, Riyadh, Saudi Arabia
| | - Rizwan Malik
- Glaucoma Division, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia
| |
Collapse
|
19
|
Kumar V, Frolov M, Dushina G, Shradqa A, Bezzabotnov A, Abu Zaalan K. Reverse meridional cyclodialysis ab interno in management of open angle glaucoma — a preliminary report. BULLETIN OF RUSSIAN STATE MEDICAL UNIVERSITY 2019. [DOI: 10.24075/brsmu.2019.081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The uveoscleral outflow as an alternate route of aqueous drainage is of great interest in glaucoma surgical treatment. A cyclodialysis cleft allows one to create a direct connection between the anterior chamber (AC) and the suprachoroidal space (SCS) which is the key element of uveoscleral outflow. The purpose of the study was to evaluate the safety and effectiveness of reverse meridional cyclodialysis ab interno (RMCai) in decreasing intraocular pressure (IOP) in patients with primary open-angle glaucoma (POAG) and refractory glaucoma (RG). Fourteen patients who exhibited POAG and RG (11 men and 3 women, age 77.3 ± 7.8 years) were included in the study. All patients underwent RMCai with the help of custom-designed spatula. The spatula, inserted through a clear corneal incision, was used to detach the ciliary body from the scleral spur to create a 2.0–2.5 mm wide and 6.0–6.5 mm deep cleft. Outcome measures were IOP change, use of hypotensive medication(s), complications, and need for a second surgery. Decrease in IOP by more than 20% and IOP between 6 and 21 mmHg without hypotensive medication constituted complete success. Similar changes in IOP with medication constituted partial success. Need for second surgery constituted failure. The follow-up period was >3 months. Baseline IOP and hypotensive medication use were 22.0 ± 8.5 mmHg (95% confidence interval (CI), 17.6–26.4) and 2.6 ± 0.9 (95% CI, 2.2–3.1). At 3, 6, 12, 18, and 24 months, complete success was achieved in 64.3%, 77.8%, 55.6%, 37.5%, and 40% of patients respectively; partial success — in 14.3%, 22.2%, 44.4%, 50.0%, and 60.0%. Four patients required a second surgery. Failure occurred because of cleft closure by fibrosis. It was concluded that RMCai is safe and effective in decreasing IOP in POAG and RG patients.
Collapse
Affiliation(s)
- V. Kumar
- Peoples' Friendship University of Russia, Moscow, Russia; Skhodnya City Hospital, Khimki, Moscow Region, Russia; Centre for eye microsurgery "Pro zrenie", Khimki, Moscow Region, Russia
| | - M.A. Frolov
- Peoples' Friendship University of Russia, Moscow, Russia
| | - G.N. Dushina
- Peoples' Friendship University of Russia, Moscow, Russia; Centre for eye microsurgery “Pro zrenie”, Khimki, Moscow Region, Russia
| | - A.S. Shradqa
- Centre for eye microsurgery "Pro zrenie", Khimki, Moscow Region, Russia
| | - A.I. Bezzabotnov
- Skhodnya City Hospital, Khimki, Moscow Region, Russia; Centre for eye microsurgery "Pro zrenie", Khimki, Moscow Region, Russia
| | | |
Collapse
|
20
|
Edwards LA, Taylor DJ, Campbell P, Shah R, Edgar DF, Crabb DP. Feeling the pressure: a cross-sectional study exploring feasibility of a healthcare Pop-Up for intraocular pressure measurements in shopping centres in England. BMJ Open 2019; 9:e030523. [PMID: 31748291 PMCID: PMC6887061 DOI: 10.1136/bmjopen-2019-030523] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVES To test the hypothesis that a shopping centre Pop-Up health check combining an intraocular pressure (IOP) check with a general health check (blood pressure (BP)) is more readily accepted by the general public than an IOP check only. We investigate public awareness of IOP compared with BP and the feasibility of measuring IOP in large numbers in a Pop-Up. DESIGN A cross-sectional study using a tailor-made healthcare Pop-Up. SETTING The 'Feeling the Pressure' Pop-Up was sited in eight regionally-different shopping centres in England. PARTICIPANTS Adult members of the public in shopping centres. METHODS On one day we measured IOP only and on another measured BP and IOP. IOP was measured by Icare IC100 tonometer (Helsinki, Finland). Potential participants were asked about their awareness of IOP and BP and when they last visited their optometrist. RESULTS More people attended the combined BP + IOP days (461; 60%; 95% CI 56% to 64%) than IOP-only days (307; 40%, 95% CI 37% to 43%) over 16 days of testing. We recorded IOP in 652 participants (median (IQR) age and IOP of 54 (42 to 68) years and 13 (11 to 15) mm Hg, respectively). Fewer people reported awareness about IOP (19%, 95% CI 16% to 23%) compared with BP (71%, 95% CI 66% to 75%). Of 768 participants, 60 (8%) reported no previous optometric eye examination and 185 (24%) reported >2 years since their most recent examination. CONCLUSIONS Measuring IOP in large numbers of the public via a shopping centre Pop-Up is feasible. Public engagement was greater when a BP check was offered alongside an IOP check, suggesting unfamiliar health checks can be promoted by aligning them with a more familiar check. Our findings hint at strategies for public health schemes that engage the public with their eye health.
Collapse
Affiliation(s)
- Laura A Edwards
- Division of Optometry and Visual Science, School of Health Sciences, City University London, London, UK
| | - Deanna J Taylor
- Division of Optometry and Visual Science, School of Health Sciences, City University London, London, UK
| | - Peter Campbell
- Division of Optometry and Visual Science, School of Health Sciences, City University London, London, UK
| | - Rakhee Shah
- Division of Optometry and Visual Science, School of Health Sciences, City University London, London, UK
| | - David F Edgar
- Division of Optometry and Visual Science, School of Health Sciences, City University London, London, UK
| | - David P Crabb
- Division of Optometry and Visual Science, School of Health Sciences, City University London, London, UK
| |
Collapse
|
21
|
Kutzscher AE, Kumar RS, Ramgopal B, Rackenchath MV, Sathi Devi, Nagaraj S, Moe CA, Fry DM, Stamper RL, Keenan JD. Reproducibility of 5 Methods of Ocular Tonometry. ACTA ACUST UNITED AC 2019; 2:429-434. [DOI: 10.1016/j.ogla.2019.07.006] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Revised: 07/15/2019] [Accepted: 07/29/2019] [Indexed: 11/25/2022]
|