1
|
Han X, Li M, Zhao J, Sun B, Zhang X, Xu H, Zhou X. Hydroxyproline Concentration and Associated Factors of Preserved Small Incision Lenticule Extraction-Derived Corneal Stromal Lenticules. Cornea 2024; 43:1285-1290. [PMID: 38967494 DOI: 10.1097/ico.0000000000003615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Accepted: 05/12/2024] [Indexed: 07/06/2024]
Abstract
PURPOSE To evaluate changes of hydroxyproline concentration and its influencing factors of small incision lenticule extraction (SMILE)-derived corneal stromal lenticules with different preservation methods. METHODS A total of 390 corneal stromal lenticules of 195 patients were derived from SMILE surgeries. Thirty of the lenticules were classified as the fresh (control) group, and the rest were randomly and evenly divided and stored in anhydrous glycerol, silicone oil, Optisol, and cryopreservation for 1 day, 1 week, or 1 month. A hydroxyproline assay kit (ab222941, Abcam) was used to measure the hydroxyproline concentration in each preservation method. Concentrations of MMP-2, TIMP-2, TNFα, TGFβ2, and reactive oxygen species were also evaluated. RESULTS In the anhydrous glycerol group, the concentration of hydroxyproline decreased within 1 week (fresh: 1 dΔ = 0.229, P < 0.001*; 1 d - 1 wΔ = 0.055, P < 0.001*) while that in the silicone oil group remained stable in 1 week (1 d - 1 wΔ = -0.005, P = 0.929) and decreased significantly in 1 m (1 m - 1 wΔ = -0.041, P = 0.003*). The sequence of hydroxyproline concentration in the Optisol group was 1 m > 1 day > 1 week. Hydroxyproline concentration in the cryopreservation group decreased within 1 m. Hydroxyproline concentration was highest in the Optisol group and lowest in the anhydrous glycerol group under the same preservation time. Hydroxyproline concentration was negatively correlated with MMP-2 (r = -0.16, P = 0.421) and TIMP-2 (r = -0.56, P = 0.002*) while MMP-2 and TNFα (r = 0.17, P = 0.242), TIMP-2 and TGFβ2 (r = 0.21, P = 0.207), and TNFα and reactive oxygen species (r = 0.52, P = 0.007*) were positively correlated. CONCLUSIONS More collagen was retained in SMILE lenticules preserved in Optisol under the same preservation time. The mechanism of the changes of collagen in preserved SMILE-derived lenticules and oxidative stress requires additional investigation.
Collapse
Affiliation(s)
- Xiaosong Han
- Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China ; and
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, China
| | - Meiyan Li
- Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China ; and
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, China
| | - Jing Zhao
- Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China ; and
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, China
| | - Bingqing Sun
- Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China ; and
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, China
| | - Xiaoyu Zhang
- Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China ; and
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, China
| | - Haipeng Xu
- Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China ; and
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, China
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China ; and
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, China
| |
Collapse
|
2
|
Holekamp NM, Yaqub M, Ranade SV, Cantrell RA, Singh S, Gazzard G. Systematic Literature Reviews Comparing the Long-Term Safety Outcomes for the Port Delivery System with Ranibizumab (PDS) Versus Other Ocular Implants. Ophthalmol Ther 2024; 13:2303-2329. [PMID: 39090513 PMCID: PMC11341515 DOI: 10.1007/s40123-024-01001-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Accepted: 07/15/2024] [Indexed: 08/04/2024] Open
Abstract
OBJECTIVES To determine whether the types and rates of post-surgical complications associated with the Port Delivery System with ranibizumab (PDS) are comparable with those reported for other ocular implants that cross the sclera. METHODS Systematic literature reviews were conducted to determine the long-term (≥ 18-month) safety of ocular implants that cross the sclera in clinical trials and real-world studies. Complication types and rates were compared with those reported for the PDS in phase III clinical trials (Archway, Pagoda, and Pavilion). RESULTS Sixteen clinical trials (24 publications) and 43 real-world studies were identified reporting 30 complications in eyes with 15 implant types and 8 ocular diseases. Implants were associated with an acceptable, well-characterized safety profile, with most complications resolving spontaneously or with treatment. Device-related complications were reported in 0.7% (0.0-5.0%) of study eyes in clinical trials and 1.3% (0.0-14.5%) of eyes in real-world studies. Rates of conjunctival complications were 2.1% (0.0-22.8%) and 2.2% (0.9-4.6%), respectively. The overall types and rates of adverse events of special interest reported for the PDS in phase III trials (cataract, conjunctival bleb, vitreous hemorrhage, conjunctival erosion, conjunctival retraction, endophthalmitis, implant dislocation, retinal detachment, and hyphema) were within the ranges reported for other ocular implants. CONCLUSIONS The rates of complications reported in phase III clinical trials for the PDS were within the ranges reported for other ocular implants that cross the sclera. This suggests that the long-term safety of the PDS is consistent with other ocular devices established in ophthalmology clinical practice. TRIAL REGISTRATION PROSPERO international prospective register of systematic reviews: CRD5202234129, CRD42022343129.
Collapse
Affiliation(s)
- Nancy M Holekamp
- Pepose Vision Institute, Chesterfield, MO, USA.
- F. Hoffmann-La Roche Ltd, Basel, Switzerland.
| | - Manejeh Yaqub
- Genentech, Inc., a Member of the Roche Group, South San Francisco, CA, USA
| | - Shrirang V Ranade
- Genentech, Inc., a Member of the Roche Group, South San Francisco, CA, USA
| | - Ronald A Cantrell
- Genentech, Inc., a Member of the Roche Group, South San Francisco, CA, USA
| | | | - Gus Gazzard
- Institute of Ophthalmology, University College London, London, UK
- NIHR Moorsfield Biomedical Research Centre, Moorfield Eye Hospital NHS Foundation Trust, London, UK
| |
Collapse
|
3
|
Ianchulev T, Weinreb RN, Kamthan G, Calvo E, Pamnani R, Ahmed IK. Biotissue stent for supraciliary outflow in open-angle glaucoma patients: surgical procedure and first clinical results of an aqueous drainage biostent. Br J Ophthalmol 2024; 108:217-222. [PMID: 36593090 PMCID: PMC10850681 DOI: 10.1136/bjo-2022-322536] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Accepted: 12/16/2022] [Indexed: 01/03/2023]
Abstract
BACKGROUND/AIMS To report a first-in-human trial in open-angle glaucoma (OAG) subjects treated with a new microinterventional biostent-reinforced cyclodialysis technique to enhance supraciliary aqueous drainage. METHODS Subjects (N=10; 74.1±7.9 years old) with OAG and cataracts underwent combined phacoemulsification cataract surgery with implantation of a permanent endoscleral supraciliary biostent to reinforce a controlled cyclodialysis cleft. The biostent comprised decellularised scleral allograft tissue microtrephined into a polymer tubular implant intraoperative/postoperative safety, intraocular pressure (IOP) and glaucoma medications were tracked through 12 months postimplantation. RESULTS Baseline medicated IOP averaged 24.2±6.9 mm Hg with subjects using 1.3±0.8 IOP-lowering medications. Successful biostent implantation was achieved in all individuals without significant complications. Immediate IOP lowering was sustained through 1 year. Twelve-month mean IOP was reduced 40% from baseline to 14.6±3.2 mm Hg (p=0.004; paired two-tailed t-test), and 80% of patients achieved >20% IOP reduction. Biostenting reduced glaucoma medication use 62%, from a baseline mean of 1.3 required medications to 0.5 medications (p=0.037) at postoperative 12 months. The biotissue implant was well tolerated and demonstrated good endothelial safety with only 11% endothelial cell loss at 12 months after combined phaco-biostenting surgery, similar to that expected after phacoemulsification alone. Mean BCVA increased from baseline 20/130 Snellen to 20/36 at postoperative 12 months (p=0.001). CONCLUSION Supraciliary biostenting in OAG patients is well tolerated, has a good safety profile and produces long-term IOP-lowering while reducing glaucoma medication requirements.
Collapse
Affiliation(s)
- Tsontcho Ianchulev
- Ophthalmology, New York Eye and Ear Infirmary of Mount Sinai, New York City, New York, USA
- UCSD, La Jolla, California, USA
| | | | - Gautam Kamthan
- New York Eye and Ear Infirmary of Mount Sinai, New York City, New York, USA
| | | | | | - Iqbal K Ahmed
- Ophthalmology and Vision Sciences, University of Toronto, Mississauga, Ontario, Canada
| |
Collapse
|
4
|
Dítě J, Netuková M, Procházková A, Poláchová M, Krivosheev K, Studený P. Scleral Grafts in Ophthalmic Surgery. A Review. CESKA A SLOVENSKA OFTALMOLOGIE : CASOPIS CESKE OFTALMOLOGICKE SPOLECNOSTI A SLOVENSKE OFTALMOLOGICKE SPOLECNOSTI 2024; 80:231-238. [PMID: 38925901 DOI: 10.31348/2024/11] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/29/2024]
Abstract
AIM To summarize the history and current trends in the use of scleral grafts in ophthalmology. MATERIALS AND METHODS We conducted a review of the literature through the MEDLINE and Cochrane Library databases. The search terms were "sclera", "graft", and "surgery". The search resulted in 1596 articles, of which we evaluated 192 as relevant. The relevant articles were sorted chronologically and according to the method of using scleral grafts, which enabled the development of a review article. RESULTS The sclera has been routinely used in ophthalmology since the 1950s in many different indications. Some of these indications have become practically obsolete over time (for example, use in the surgical management of retinal detachment), but a large number still find application today (especially use in glaucoma or oculoplastic surgery, or as a patch for a defect in the sclera or cornea). CONCLUSION Even though allogeneic sclera is currently used less frequently in ophthalmology compared to other tissue banking products and the range of its indications has partially narrowed, it remains a useful material due to its availability and properties.
Collapse
|
5
|
Kitnarong N, Srikulsasitorn B, Aurboonsong T. Response to Letter to the Editor: Glycerin-preserved, Human-donor, Corneoscleral Patch Grafts for Glaucoma Drainage Devices. J Glaucoma 2022; 31:e13. [PMID: 34954751 DOI: 10.1097/ijg.0000000000001976] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Affiliation(s)
- Naris Kitnarong
- Department of Ophthalmology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | | | | |
Collapse
|
6
|
Capasso L, Salerno G, Tortori A, De Bernardo M. Letter to the Editor: Glycerin-preserved, Human-donor, Corneoscleral Patch Grafts for Glaucoma Drainage Devices. J Glaucoma 2021; 30:1018. [PMID: 33927151 DOI: 10.1097/ijg.0000000000001863] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Affiliation(s)
- Luigi Capasso
- Department of Ophthalmology, Ospedale delMare, ASL NA1 Centro, Naples
| | - Giulio Salerno
- Department of Medicine, Surgery and Dentistry, "Salerno Medical School," University of Salerno, Salerno, Italy
| | - Antonia Tortori
- Department of Ophthalmology, Ospedale delMare, ASL NA1 Centro, Naples
| | - Maddalena De Bernardo
- Department of Medicine, Surgery and Dentistry, "Salerno Medical School," University of Salerno, Salerno, Italy
| |
Collapse
|
7
|
Karaca U, Usta G. The usability of lamellar scleral autograft in ocular perforation treatment. Int Ophthalmol 2021; 42:377-383. [PMID: 34176032 DOI: 10.1007/s10792-021-01922-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Accepted: 06/19/2021] [Indexed: 11/27/2022]
Abstract
IMPORTANCE Open globe injury is a frequent and preventable healthcare problem with an annual incidence of 3.5/100,000 worldwide. Management and treatment methods aim to ensure globe integrity. Unfortunately, it is not possible to achieve globe integrity in some of the cases, and these can result in poor visual outcomes. PURPOSE To evaluate the usability of lamellar scleral graft in the repair of ocular perforations. METHODS This was a retrospective review of 11 patients who underwent lamellar scleral graft surgery for ocular perforation between June 2015 and June 2020. Due to the failure of the repairs when other techniques were used, the perforation zones were sealed with lamellar scleral autografts. The primary measures of the outcomes were globe integrity, postoperative best corrected visual acuity, and intraocular pressure (IOP). Visual acuity was determined using the Snellen eye chart, and IOP was measured using the automated pneumatic tonometry during standard examination. RESULTS The participants enrolled in this study included 11 patients who underwent lamellar scleral patch graft between 2015 and 2020. The mean age of the patients was 58.81 ± 16.6 years (range, 16-77), and the mean follow-up period was 12.5 ± 3.8 months (range, 8-20). During the surgery, the perforation zone was treated and no leakage was observed. IOP significantly increased, and visual acuity improved in almost all eyes. The factors that made it necessary to use scleral grafts in patients were star-shaped wounds, delayed presentation, lost corneal / scleral tissue. CONCLUSION Lamellar scleral graft is a method that can be used in the treatment of defective ocular perforation with acceptable complications and provides adequate functional and structural stability. Scleral patch grafting can be considered as an alternative option for surgeons treating a variety of ocular conditions that cause tectonic imbalance or poor cosmesis.
Collapse
Affiliation(s)
- Umut Karaca
- Department of Ophthalmology, Faculty of Medicine, Isparta Suleyman Demirel University, Isparta, Turkey.
| | - Gulsah Usta
- Department of Ophthalmology, Faculty of Medicine, Isparta Suleyman Demirel University, Isparta, Turkey
| |
Collapse
|