1
|
Sella R, Reitblat O, Durnford KM, Pettey JH, Olson RJ, Hahn TE, Bernhisel AA, Afshari NA. The effect of patient age on some new and older IOL power calculation formulas. Acta Ophthalmol 2024; 102:e696-e704. [PMID: 38155407 DOI: 10.1111/aos.16621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Revised: 12/12/2023] [Accepted: 12/18/2023] [Indexed: 12/30/2023]
Abstract
PURPOSE To assess the accuracy of intraocular lens (IOL) power calculation in different age groups using various IOL calculation formulas. METHODS Data from 421 eyes of 421 patients ≥60 years old (ages: 60-69, n = 131; 70-74, n = 105; 75-84, n = 158 and ≥85, n = 27), who underwent uneventful cataract surgery with SN60WF IOL implantation at John A. Moran Eye Center, Salt Lake City, USA, were retrospectively obtained. The SD of the prediction error (PE), median and mean absolute PEs and the percentage of eyes within ±0.25, ±0.50, ±0.75 and ±1.00 D were calculated after constant optimizations for the following formulas: Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO) 2.0, Haigis, Hoffer Q, Hoffer QST, Holladay 1, Kane, Radial Basis Function (RBF) 3.0 and SRK/T. Results were compared between the different age groups. RESULTS Predictability rates within 0.25D were lower for the eldest age group compared with the other groups using the EVO 2.0 (33% vs. 37%-53%, p = 0.045), Kane (26% vs. 35%-50%, p = 0.034) and SRK/T (22% vs. 31%-49%, p = 0.002). Higher median absolute refractive errors for all formulas were observed in the oldest group [range: 0.39 D (Haigis, Hoffer QSR)-0.48 D (Kane)], followed by the youngest group [range: 0.30 D (RBF 3.0)-0.39 D (Holladay 1, SRK/T)] but did not reach statistical significance. No significant differences between the groups in the distribution parameter were seen. CONCLUSION Current IOL power calculation formulas may have variable accuracy for different age groups. This should be taken into account when planning cataract surgery to improve refractive outcomes.
Collapse
Affiliation(s)
- Ruti Sella
- Department of Ophthalmology, Rabin Medical Center, Petah Tikva, Israel
- Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
- Department of Ophthalmology, Mayo Clinic, Rochester, Minnesota, USA
- Viterbi Family Department of Ophthalmology, Shiley Eye Institute, University of California San Diego, La Jolla, California, USA
| | - Olga Reitblat
- Department of Ophthalmology, Rabin Medical Center, Petah Tikva, Israel
- Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | | | - Jeff H Pettey
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Randall J Olson
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Tara E Hahn
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Ashlie A Bernhisel
- Department of Ophthalmology, Mayo Clinic, Rochester, Minnesota, USA
- Viterbi Family Department of Ophthalmology, Shiley Eye Institute, University of California San Diego, La Jolla, California, USA
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Natalie A Afshari
- Viterbi Family Department of Ophthalmology, Shiley Eye Institute, University of California San Diego, La Jolla, California, USA
| |
Collapse
|
2
|
Kato Y, Kojima T, Tamaoki A, Tanaka Y, Yamamoto N, Ichikawa K. Accuracy of the Majority Voting Method with Multiple IOL Power Formulae. Clin Ophthalmol 2024; 18:1341-1351. [PMID: 38765457 PMCID: PMC11100961 DOI: 10.2147/opth.s457627] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Accepted: 04/24/2024] [Indexed: 05/22/2024] Open
Abstract
Purpose This study aimed to evaluate the efficacy of a majority decision algorithm that integrates intraoperative aberrometry (IA) and two intraocular lens (IOL) frequency formulas. The primary objective was to compare the accuracy of three formulas (IA; Sanders, Retzlaff, and Kraff/Theoretical (SRK/T); and Barrett Universal II (BUII)), in achieving emmetropia in eyes implanted with TFNT lenses (Alcon). Patients and Methods A total of 145 eyes of 145 patients were included in the evaluation. Preoperative data were obtained from IOLMaster 700, while intraoperative data were collected from ORA SYSTEMTM. Visual acuity ≥0.8 at the 3-month post-surgery mark was confirmed. We assessed refractive prediction error (RPE), which is the difference between predicted refraction (PR) and postoperative subjective refraction. This evaluation aimed to identify the optimal IOL power with the implemented algorithm. Results Among the 145 eyes evaluated, 55.9%, 78.7%, and 97.2% achieved postoperative subjective refraction within ±0.13 Diopters (D), ±0.25 D, and ±0.50 D, respectively. The percentages of eyes within ±0.25 D of PR varied by formula type, with values of 57%, 57%, and 54% for IA, BUII, and SRK/T, respectively. For eyes with short to medium axial length (AL<26.00 mm), the percentages within ±0.25 D of RPE were 52%, 58%, and 58% for IA, SRK/T, and BUII, respectively. In contrast, for eyes with long axial length (≥26.00 mm) the percentages were 68%, 52%, and 45% for IA, BUII, and SRK/T, respectively. Conclusion The proposed majority decision algorithm incorporating IA and two IOL frequency formulas was effective in reducing postoperative refractive error. IA was particularly beneficial for eyes with long axial length. These findings suggest the algorithm has potential to optimize IOL power selection to improve quality of life of patients and clinical practice outcomes.
Collapse
Affiliation(s)
| | - Takashi Kojima
- Chukyo Eye Clinic, Nagoya, Aichi, Japan
- Nagoya Eye Clinic, Nagoya, Aichi, Japan
| | - Akeno Tamaoki
- Department of Ophthalmology, Japan Community Health Care Organization Chukyo Hospital, Nagoya, Aichi, Japan
| | | | - Naoki Yamamoto
- Center for Society-Academia Collaboration, Research Promotion Headquarters, Fujita Health University, Toyoake, Aichi, Japan
- International Center for Cell and Gene Therapy, Research Promotion Headquarters, Fujita Health University, Toyoake, Aichi, Japan
| | | |
Collapse
|
3
|
Nilsen C, Gundersen M, Graae Jensen P, Gundersen KG, Potvin R, Utheim ØA, Gjerdrum B. The Significance of Dry Eye Signs on Preoperative Keratometry Measurements in Patients Scheduled for Cataract Surgery. Clin Ophthalmol 2024; 18:151-161. [PMID: 38259819 PMCID: PMC10800283 DOI: 10.2147/opth.s448168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Accepted: 01/08/2024] [Indexed: 01/24/2024] Open
Abstract
Purpose The primary objective was to investigate if subjects with dry eyes had increased variability of keratometry measurements prior to cataract surgery compared to subjects with non-dry eyes. Secondary objectives were to determine which separate signs affected keratometry. Patients and Methods This study was part of a prospective interventional randomized controlled trial. After dry eye diagnostics were performed (signs only) subjects were divided into sign of dry eye (SDE) positive and negative groups. To investigate variability, we performed two keratometry measurements for each subject with three different optical biometers: Anterion (OCT optical biometer), Eyestar (combined OCT and reflection-based optical biometer), and Lenstar (reflection based-optical biometer). Results One hundred and thirty-one subjects were available for analysis. The variability of astigmatism was significantly higher for subjects with hyperosmolarity compared to normal eyes for the Lenstar, as was the percentage of eyes with variability of astigmatism greater than 0.25 D. The percentage of eyes with variability of average K greater than 0.25 D was higher for subjects with non-invasive keratograph break-up time <10 seconds (NIKBUT positive) compared to normal eyes for the Lenstar. Conclusion Combined diagnostic criteria (signs only) showed no statistically significant differences for keratometry measurements between SDE positive and negative. Eyes with hyperosmolarity and NIKBUT positive showed statistically higher variability of keratometry measurements compared to normal eyes for Lenstar, but not for the Anterion or Eyestar biometers.
Collapse
Affiliation(s)
| | | | | | | | | | - Øygunn A Utheim
- Department of Medical Biochemistry, Oslo University Hospital, Oslo, Norway
- Department of Ophthalmology, Oslo University Hospital, Oslo, Norway
- The Norwegian Dry Eye Clinic, Oslo, Norway
| | | |
Collapse
|
4
|
Danilenko EV, Kulikov AN, Makarova NV. [Analysis of intraocular lens displacement relative to the haptic plane by ultrasound biomicroscopy data]. Vestn Oftalmol 2023; 139:11-16. [PMID: 37067927 DOI: 10.17116/oftalma202313902111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/18/2023]
Abstract
PURPOSE This study analyzed cases with postoperative displacement of intraocular lens (IOL) relative to the haptic plane using ultrasound biomicroscopy (UBM). MATERIAL AND METHODS The study analyzed biometry data of 231 patients (277 eyes) aged 72.39±7.77 years, among them 43.25% were males. IOL position and refraction were analyzed at 1, 3 and 6 months after standard phacoemulsification. RESULTS AND DISCUSSION UBM was performed to analyze the position of the IOL. Stabilization of lens position was observed by the 3rd month of observation. Among the cases with displacement of the optical part relative to the haptic plane, the forward shift was determined in 24.85%, backward - in 16.67% of cases. Eyes with opposite IOL displacements differed significantly in lens diameter, ciliary sulcus diameter and the power of implanted IOL. IOL shift towards the retina produced significant hyperopic refractive error. A discriminant function was compiled using preoperative biometry data comprising the model for predicting backward IOL displacement with high probability. However, we failed to obtain a qualitative model for forward IOL displacements. CONCLUSION Calculation error in modern formulas could occur because of IOL displacement, including the shift of the optical part relative to the haptic plane in postoperative period. Analysis of biometry data allows calculating IOL displacement towards the retina with a high probability, which could help avoid hyperopic refraction error postoperatively.
Collapse
Affiliation(s)
- E V Danilenko
- S.M. Kirov Medical Military Academy, Saint Petersburg, Russia
| | - A N Kulikov
- S.M. Kirov Medical Military Academy, Saint Petersburg, Russia
| | - N V Makarova
- Nikiforov Russian Center of Emergency and Radiation Medicine, Saint Petersburg, Russia
| |
Collapse
|
5
|
Li C, Wang M, Feng R, Liang F, Liu X, He C, Fan S. Comparison of Formula-Specific Factors and Artificial Intelligence Formulas with Axial Length Adjustments in Bilateral Cataract Patients with Long Axial Length. Ophthalmol Ther 2022; 11:1869-1881. [PMID: 35917084 PMCID: PMC9437155 DOI: 10.1007/s40123-022-00551-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2022] [Accepted: 07/18/2022] [Indexed: 11/11/2022] Open
Abstract
Introduction To evaluate and compare the effectiveness for reducing the prediction error (PE) of the second eye using formula-specific factors, artificial intelligence (AI) formulas (PEARL-DGS and Kane), and the Cooke-modified axial length (CMAL) methods in bilateral cataract patients with long axial length (AL). Methods A total of 98 patients with long AL who underwent sequential bilateral cataract surgeries were retrospectively enrolled. The second-eye IOL power was calculated by the formula-specific factors, AI formulas, and CMAL methods when the first eye suffered from refraction surprise. The correction factors of eight formulas were calculated by regression analysis. Results There was a significant correlation between bilateral preoperative biometric parameters (P < 0.05) as well as bilateral PE (P < 0.05). The Kane formula displayed the lowest median absolute error (MedAE) and highest proportion of PE within ± 0.50 and ± 1.00 D compared with other formulas for the first eye. For the second-eye refinement, all three methods could reduce the second-eye MedAE. The formula-specific correction factors were 0.250, 0.331, 0.343, 0.394, 0.409, 0.452, 0.503, and 0.520 for Kane, Barrett Universal II (BUII), PEARL-DGS, Holladay 2, Holladay 1, Haigis, Hoffer Q, and SRK/T, respectively. The new AI-based Kane and PEARL-DGS with or without the CMAL methods could improve the refractive outcomes of the second eye in sequential bilateral cataract patients with long AL. The Kane, BUII, and PEARL-DGS with specific correction factors displayed higher accuracy compared with the other two methods (P < 0.05). Conclusions The new AI-based Kane and PEARL-DGS with or without the CMAL methods could improve the refractive outcomes of the second eye in sequential bilateral cataract patients with long AL. Notably, the Kane, PEARL-DGS, and BUII with specific correction factors displayed higher accuracy. Supplementary Information The online version contains supplementary material available at 10.1007/s40123-022-00551-6.
Collapse
Affiliation(s)
- Chuang Li
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, 510060, People's Republic of China
| | - Mingwei Wang
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, 510060, People's Republic of China
| | - Rui Feng
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, 510060, People's Republic of China
| | - Feiyan Liang
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, 510060, People's Republic of China
| | - Xialin Liu
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, 510060, People's Republic of China
| | - Chang He
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, 510060, People's Republic of China.
| | - Shuxin Fan
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, 510060, People's Republic of China.
| |
Collapse
|
6
|
Evaluation of IOL power calculation with the Kane formula for pediatric cataract surgery. Graefes Arch Clin Exp Ophthalmol 2022; 260:2877-2885. [PMID: 35895106 DOI: 10.1007/s00417-022-05779-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 06/07/2022] [Accepted: 07/19/2022] [Indexed: 11/04/2022] Open
Abstract
PURPOSE To assess the accuracy of the Kane formula for intraocular lens (IOL) power calculation in the pediatric population. METHODS The charts of pediatric patients who underwent cataract surgery with in-the-bag IOL implantation with one of two IOL models (SA60AT or MA60AC) between 2012 and 2018 in The Hospital for Sick Children, Toronto, Ontario, CanFada, were retrospectively reviewed. The accuracy of IOL power calculation with the Kane formula was evaluated in comparison with the Barrett Universal II (BUII), Haigis, Hoffer Q, Holladay 1, and Sanders-Retzlaff-Kraff Theoretical (SRK/T) formulas. RESULTS Sixty-two eyes of 62 patients aged 6.2 (IQR 3.2-9.2) years were included. The SD values of the prediction error obtained by Kane (1.38) were comparable with those by BUII (1.34), Hoffer Q (1.37), SRK/T (1.40), Holaday 1 (1.41), and Haigis (1.50), all p > 0.05. A significant difference was observed between the Hoffer Q and Haigis formulas (p = 0.039). No differences in the median and mean absolute errors were found between the Kane formula (0.54 D and 0.91 ± 1.04 D) and BUII (0.50 D and 0.88 ± 1.00 D), Hoffer Q (0.48 D and 0.88 ± 1.05 D), SRK/T (0.72 D and 0.97 ± 1.00 D), Holladay 1 (0.63 D and 0.94 ± 1.05 D), and Haigis (0.57 D and 0.98 ± 1.13 D), p = 0.099. CONCLUSION This is the first study to investigate the Kane formula in pediatric cataract surgery. Our results place the Kane among the noteworthy IOL power calculation formulas in this age group, offering an additional means for improving IOL calculation in pediatric cataract surgery. The heteroscedastic statistical method was first implemented to evaluate formulas' predictability in children.
Collapse
|
7
|
Guo C, Yin S, Qiu K, Zhang M. Comparison of accuracy of intraocular lens power calculation for eyes with an axial length greater than 29.0 mm. Int Ophthalmol 2022; 42:2029-2038. [PMID: 35536455 PMCID: PMC9085560 DOI: 10.1007/s10792-021-02194-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Accepted: 12/19/2021] [Indexed: 02/05/2023]
Abstract
PURPOSE To evaluate and compare the accuracy of six different formulas (Emmetropia Verifying Optical version 2.0, Kane, SRK/T, Barrett Universal II, Haigis and Olsen) in intraocular lens (IOL) power calculation for extremely long eyes. METHODS Retrospective case-series. Seventy-three eyes with axial length (AL) ≥ 29.0 mm and underwent phacoemulsification cataract surgery with Rayner (Hove, UK) 920H IOL implantation from January 2018 to March 2020 were included. Prediction errors (PE) were calculated and compared between different formulas to evaluate the accuracy of formulas. Multiple regression analysis was performed to investigate factors associated with the PE. RESULTS The Kane formula had mean prediction error close to zero (- 0.01 ± 0.51 D, P = 0.841), whereas the EVO 2.0, SRK/T, Barrett Universal II, Haigis and Olsen formulas produced hyperopic outcomes (all P < 0.001). The median absolute error [inter-quartile range] produced by the EVO 2.0, Kane, Barrett Universal II and Olsen formulas showed no significant difference (0.33 D [0.48], 0.30 D [0.44], 0.34 D [0.39], 0.29 D [0.37], respectively, pairwise comparison P > 0.05), but was significantly lower than that of the SRK/T and Haigis formulas (0.85 D [0.66], 0.80 D [0.54], respectively, pairwise comparison P < 0.001). The AL and the PE produced by the SRK/T formula were significantly positively correlated in extremely myopic eyes (β = 0.248, P < 0.001), whereas the trend was not demonstrated in other formulas. CONCLUSIONS For cataract patients with axial length greater than 29.0 mm, the accuracy of the EVO 2.0, Kane, Barrett Universal II and Olsen formulas is comparable and significantly better than that of the SRK/T and Haigis formulas.
Collapse
Affiliation(s)
- Chengyao Guo
- Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, North Dongxia Road, Shantou, 515041, Guangdong, China
- Shantou University Medical College, Shantou, Guangdong, China
| | - Shengjie Yin
- Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, North Dongxia Road, Shantou, 515041, Guangdong, China
| | - Kunliang Qiu
- Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, North Dongxia Road, Shantou, 515041, Guangdong, China
| | - Mingzhi Zhang
- Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, North Dongxia Road, Shantou, 515041, Guangdong, China
| |
Collapse
|
8
|
Abstract
PURPOSE OF REVIEW We review recent studies comparing intraocular lens (IOL) formulas with an emphasis on selection of the highest performing formulas based on patient axial length, age, and history of previous corneal refractive surgery. RECENT FINDINGS The Barrett Universal II formula based on a theoretical model has consistently demonstrated high accuracy. The Olsen four-factor formula using ray tracing optics and the Hill-RBF calculator using artificial intelligence have also demonstrated good prediction results after being updated. Notably, the Kane formula, incorporating artificial intelligence, has overall shown the best performance for all axial lengths. Although newly developed and updated IOL formulas have improved refractive prediction in patients with short or long axial length eyes or prior history of corneal refractive surgery, these challenging cases still require special consideration. The Barrett True-K formula has shown accurate results regardless of preoperative data in eyes with previous myopic refractive surgery. SUMMARY Advancements in optical biometry and IOL calculation formulas continue to improve refractive outcomes. The clinician can optimize refractive outcomes in the majority of patients with the use of formulas that have shown consistent results and accuracy in several large studies.
Collapse
|
9
|
Ryu S, Jun I, Kim TI, Kim EK, Seo KY. Accuracy of the Kane Formula for Intraocular Lens Power Calculation in Comparison with Existing Formulas: A Retrospective Review. Yonsei Med J 2021; 62:1117-1124. [PMID: 34816642 PMCID: PMC8612861 DOI: 10.3349/ymj.2021.62.12.1117] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 09/14/2021] [Accepted: 09/27/2021] [Indexed: 11/27/2022] Open
Abstract
PURPOSE To evaluate the accuracy of the Kane formula for intraocular lens (IOL) power calculation in comparison with existing formulas by incorporating optional variables into calculation. MATERIALS AND METHODS This retrospective review consisted of 78 eyes of patients who had undergone uneventful phacoemulsification with intraocular implantation at Severance Hospital in Seoul, Korea between February 2020 and January 2021. The Kane formula was compared with six of the existing IOL formulas (SRK/T, Hoffer-Q, Haigis, Holladay1, Holladay2, Barrett Universal II) based on the mean absolute error (MAE), median absolute error (MedAE), and the percentages of eyes within prediction errors of ±0.25D, ±0.50D, and ±1.00D. RESULTS The Barrett Universal II formula demonstrated the lowest MAEs (0.26±0.17D), MedAEs (0.28D), and percentage of eyes within prediction errors of ±0.25D, ± 0.50D, and ±1.00D, although there was no statistically significant difference between Barrett Universal II-SRK/T (p=0.06), and Barrett Universal II-Kane formula (p<0.51). Following the Barrett Universal II formula, the Kane formula demonstrated the second most accurate formula with MAEs (0.30±0.19D) and MedAEs (0.28D). However, no statistical difference was shown between Kane-Barrett Universal II (p=0.51) and Kane-SRK/T (p=0.14). CONCLUSION Although slightly better refractory outcome was noted in the Barrett Universal II formula, the performance of the Kane formula in refractive prediction was comparable in IOL power calculation, marking its superiority over many conventional IOL formulas, such as HofferQ, Haigis, Holladay1, and Holladay2.
Collapse
Affiliation(s)
- Soyoung Ryu
- The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea
| | - Ikhyun Jun
- The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea
- Corneal Dystrophy Research Institute, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea.
| | - Tae-Im Kim
- The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea
- Corneal Dystrophy Research Institute, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea
| | - Eung Kweon Kim
- Corneal Dystrophy Research Institute, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea
- Saevit Eye Hospital, Goyang, Korea
| | - Kyoung Yul Seo
- The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea
- Corneal Dystrophy Research Institute, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea.
| |
Collapse
|
10
|
Lin L, Xu M, Mo E, Huang S, Qi X, Gu S, Sun W, Su Q, Li J, Zhao YE. Accuracy of Newer Generation IOL Power Calculation Formulas in Eyes With High Axial Myopia. J Refract Surg 2021; 37:754-758. [PMID: 34756144 DOI: 10.3928/1081597x-20210712-08] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To compare the accuracy of the Barrett Universal II, Emmetropia Verifying Optical (EVO), Haigis, Kane, and SRK/T formulas for intraocular lens power calculation in patients with high axial myopia. METHODS In this retrospective study, 175 eyes (175 patients) that underwent uneventful cataract surgery were enrolled. According to the axial length (AL), the eyes were divided into long AL (26 ⩽ AL < 28 mm), super long AL (28 ⩽ AL < 30 mm), and extremely long AL (⩾ 30 mm). The mean absolute prediction errors (MAE) 3 months postoperatively and the percentage of eyes within different prediction error were compared, followed by subgroup analysis. RESULTS The MAE and percentage of eyes within ±0.50 diopters (D) of the five formulas were as follows: Barrett Universal II (0.342, 74.9%), EVO 2.0 (0.314, 82.3%), Haigis (0.336, 74.9%), Kane (0.318, 78.9%), and SRK/T (0.398, 69.7%) (P = .552 and .071, respectively). Although no significant difference was found among the five formulas in the super and extremely long AL groups (P = .792 and .227, respectively), the EVO 2.0 formula achieved the highest accuracy (88.9%, 72 of 81) in the long AL group (P = .049). Moreover, the accuracy of the EVO 2.0 and Haigis formulas was stable, regardless of AL. The SRK/T formula showed a negative trend in the long and super long AL groups, whereas the Barrett Universal II, Kane, and SRK/T formulas showed positive trends in the extremely long AL group. CONCLUSIONS Overall, the EVO 2.0 and Kane formulas achieved better results in patients with high axial myopia, whereas the other three formulas showed slightly poor outcomes. [J Refract Surg. 2021;37(11):754-758.].
Collapse
|