1
|
Tawfik KO, Khan MMR, Patro A, Smetak MR, Haynes D, Labadie RF, Gifford RH, Noble JH. Cochlear Implantation of Slim Precurved Arrays Using Automatic Preoperative Insertion Plans. Otol Neurotol 2025:00129492-990000000-00809. [PMID: 40364437 DOI: 10.1097/mao.0000000000004525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/15/2025]
Abstract
HYPOTHESIS Preoperative cochlear implant (CI) electrode array (EL) insertion plans created by automated image analysis methods can improve positioning of slim precurved EL. BACKGROUND This study represents the first evaluation of a system for patient-customized EL insertion planning for a slim precurved EL. METHODS Twenty-one temporal bone specimens were divided into experimental and control groups and underwent cochlear implantation. For the control group, the surgeon performed a traditional insertion without an insertion plan. For the experimental group, customized insertion plans guided entry site, trajectory, curl direction, and base insertion depth. An additional 35 clinical insertions from the same surgeon were analyzed, 7 of which were conducted using the insertion plans. EL positioning was analyzed using postoperative imaging auto-segmentation techniques, allowing measurement of angular insertion depth (AID), mean modiolar distance (MMD), and scalar position. RESULTS In the cadaveric temporal bones, three scalar translocations, including two foldovers, occurred in 14 control group insertions. In the clinical insertions, translocations occurred in 2 of 28 control cases. No translocations or folds occurred in the seven experimental temporal bone and the seven experimental clinical insertions. Among the nontranslocated cases, overall AID and MMD were 401 ± 41 degrees and 0.34 ± 0.13 mm for the control insertions. AID and MMD for the experimental insertions were 424 ± 43 degrees and 0.34 ± 0.09 mm overall and were 432 ± 19 degrees and 0.30 ± 0.07 mm for cases where the planned insertion depth was achieved. CONCLUSIONS Trends toward improved EL positioning within scala tympani were observed when EL insertion plans are used. Variability in MMD was significantly reduced (0.07 versus 0.13 mm, p = 0.039) when the planned depth was achieved.
Collapse
Affiliation(s)
- Kareem O Tawfik
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Mohammad M R Khan
- Department of Computer and Data Science, Meharry Medical College, Nashville, Tennessee
| | - Ankita Patro
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Miriam R Smetak
- Department of Otolaryngology-Head & Neck Surgery, Washington University School of Medicine, St. Louis, Missouri
| | - David Haynes
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Robert F Labadie
- Department of Otolaryngology-Head & Neck Surgery, Medical University of South Carolina, Charleston, South Carolina
| | | | | |
Collapse
|
2
|
Chabuz CA, Hartl RMB, Rodriguez K, Gonzalez J, Cass SP, Greene NT. Characterization of Tip Fold-Over Using Fluoroscopy and Intracochlear Pressure in Cadaver Specimens. Laryngoscope 2025; 135:1795-1802. [PMID: 39719824 PMCID: PMC11981849 DOI: 10.1002/lary.31977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 12/03/2024] [Accepted: 12/05/2024] [Indexed: 12/26/2024]
Abstract
OBJECTIVES Cochlear implant array malpositioning is associated with impaired speech perception, vertigo, and facial nerve stimulation. Tip fold-over is a subset of malpositioning that occurs more often with perimodiolar electrodes, but historically it has not been characterized due to lack of knowledge regarding electrode movements of the electrode within the cochlea. The aim of this study was to characterize the mechanics of tip fold-over events and their associated insertion pressure profiles. METHODS Cadaveric human heads were surgically prepared with a mastoidectomy and facial recess. Fiberoptic pressure sensors were inserted into the scala vestibuli and tympani to measure intracochlear pressures. Perimodiolar CI electrodes (Cochlear Slim-Modiolar, CI532) were inserted via round window under fluoroscopy. RESULTS Three types of tip fold-over events were observed: anterior-posterior C-shaped, medial-lateral C-shaped, and S-shaped roll-overs. The largest transient pressures occurred with anterior-posterior and S-type roll-over, and were associated with rotation or twisting inside the cochlea. CONCLUSIONS Results demonstrate at least three subtypes of tip fold-overs. Elevated pressure transients were noted before and during the tip fold-over event related to electrode twisting. The characterization of tip fold-over into subtypes is novel and may aid identification of tip fold-over events intraoperatively in the future. It remains important to identify tip fold-over events, and they should be recognized early using a multimodal verification system. Further investigation is still required to determine the significance of these changes and other possible patterns of intracochlear electrode movement. LEVEL OF EVIDENCE NA: Cadaver study Laryngoscope, 135:1795-1802, 2025.
Collapse
Affiliation(s)
- Carolyn A Chabuz
- Department of Otolaryngology, University of Colorado School of Medicine, Aurora, Colorado
| | - Renee M Banakis Hartl
- Department of Otolaryngology-Head and Neck Surgery, University of Michigan, Ann Arbor, MI
| | - Kenny Rodriguez
- Cedar Valley Center for ENT Sinus & Allergy - Waterloo Clinic, Waterloo, IA
| | | | - Stephen P Cass
- Department of Otolaryngology, University of Colorado School of Medicine, Aurora, Colorado
| | - Nathaniel T Greene
- Department of Otolaryngology, University of Colorado School of Medicine, Aurora, Colorado
| |
Collapse
|
3
|
Arambula AM, Piper R, Murray G, Mowry SE, Rivas A, Semaan M, Manzoor NF, Killeen DE, Kelsall DC, Lupo JE, Biever A, Stidham KR, Albinus R, Morgan S, Kaplan BJ, Presley R, Menendez S, Tejani VD. Sensitivity and Specificity of Intraoperative TransImpedance Matrix Recordings Compared With X-ray Imaging in Detecting Perimodiolar Cochlear Implant Tip Foldovers: A Multicenter Study. Otol Neurotol 2025:00129492-990000000-00784. [PMID: 40210225 DOI: 10.1097/mao.0000000000004502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/12/2025]
Abstract
OBJECTIVE Characterize the sensitivity and specificity of TransImpedance Matrix (TIM) recordings compared with x-rays in detecting cochlear implant tip foldovers. STUDY DESIGN Retrospective. SETTING Multi-institutional, academic and private surgery centers. PATIENTS Patients 6 months and older undergoing cochlear implantation. INTERVENTIONS After cochlear implant array insertion, intraoperative TIM recordings and x-rays were conducted to confirm appropriate placement. If a foldover was identified, repeat insertion, followed by TIM and x-ray, was performed. MAIN OUTCOME MEASURES Presence of tip foldovers as determined by TIM recordings and x-rays. RESULTS There were 13 tip foldovers out of 484 insertions, yielding a 2.7% tip foldover rate. Using x-rays as the "gold standard," TIM recordings showed 100% sensitivity, 99.6% specificity, 84.6% positive predictive value (PPV), and 100% negative predicative value in detecting tip foldovers. The x-ray images for two TIM-identified tip foldovers were interpreted as normal intraoperatively (apparent false positives), but then were interpreted as foldovers when presented to the operating surgeon postoperatively in a blinded fashion. If these false positives had been reclassified as true positives, TIM specificity and PPV would both improve to 100%. CONCLUSIONS These results provide further support regarding the utility of TIM recordings to evaluate appropriate cochlear implant electrode array position. Despite the low tip foldover rate reported across the literature and within this study, this multicenter patient group provided a large sample size to calculate the sensitivity and specificity of TIM recordings in identifying tip foldovers. Compared with the reference-standard, x-ray imaging, TIM recordings show equivalent, and in some cases superior, performance in identification of tip foldovers. Thus, use of TIM can potentially preclude the need for routine intraoperative x-rays without compromising patient care.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Nauman F Manzoor
- Department of Otolaryngology-Head and Neck Surgery, Virginia Commonwealth University, Richmond, Virginia
| | | | | | - J Eric Lupo
- Rocky Mountain Ear Center, Englewood, Colorado
| | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Knörle E, Vazzana C, Stöver T, Helbig S. Influence of surgeon experience on the incidence of tip fold-over with slim preformed cochlear implant electrodes. Eur Arch Otorhinolaryngol 2025:10.1007/s00405-025-09235-w. [PMID: 39891694 DOI: 10.1007/s00405-025-09235-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2024] [Accepted: 01/14/2025] [Indexed: 02/03/2025]
Abstract
PURPOSE To assess whether increasing experience with implantation of a thin preformed electrode array for perimodiolar insertion reduces the incidence of tip fold-over (TFO). METHODS The retrospective study included 100 patients who received a cochlear implant (CI) with the Slim Modiolar (SM) electrode array (Cochlear, Sydney, Australia) at a university CI centre between November 2015 and December 2022. Postoperative radiological imaging was performed to verify electrode position. Surgical reports and radiological images were reviewed and the incidence of TFO was analyzed for three experienced CI surgeons. In addition, the incidence of intraoperative measurements showing evidence of electrode malposition and the mean duration of surgery over time were documented. RESULTS 129 SM implantations in 100 patients were included. In seven cases (5.4%) TFO was radiologically detected and successfully revised. In eight cases (6.2%), electrophysiological measurements indicated misplacement and the position was corrected during the same surgery. For one surgeon, five out of 67 implantations (7.5%) were affected by TFO, with the frequency of this complication decreasing over time. The average surgery time for all surgeons was 122.2 (± 44.2) minutes, with two surgeons showing a decrease over time. CONCLUSION The results show a tendency that the SM electrodes can be implanted with a lower complication rate and faster over time. Therefore, it can be assumed that the implantation of the SM electrode requires a certain amount of practice, even for experienced surgeons. As intraoperative electrophysiological measurements detected 71.4% of all radiologically confirmed TFOs, their use is highly recommended.
Collapse
Affiliation(s)
- Esther Knörle
- Department of Otorhinolaryngology, Head and Neck Surgery, Goethe University Frankfurt, University Hospital, Theodor-Stern-Kai 7, D-60590, Frankfurt am Main, Germany
| | - Caterina Vazzana
- Department of Otorhinolaryngology, Head and Neck Surgery, Goethe University Frankfurt, University Hospital, Theodor-Stern-Kai 7, D-60590, Frankfurt am Main, Germany
| | - Timo Stöver
- Department of Otorhinolaryngology, Head and Neck Surgery, Goethe University Frankfurt, University Hospital, Theodor-Stern-Kai 7, D-60590, Frankfurt am Main, Germany
| | - Silke Helbig
- Department of Otorhinolaryngology, Head and Neck Surgery, Goethe University Frankfurt, University Hospital, Theodor-Stern-Kai 7, D-60590, Frankfurt am Main, Germany.
| |
Collapse
|
5
|
Radomska K, Talar M, Haber K, Mierzwińska-Dolny P, Fishman AJ, Mierzwiński J. Transimpedance Matrix Measurement (TIM) Parameters Evaluation for the Assessment of Cochlear Implant Electrode Placement and Modiolar Proximity in Children. Biomedicines 2025; 13:319. [PMID: 40002732 PMCID: PMC11852905 DOI: 10.3390/biomedicines13020319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2024] [Revised: 01/03/2025] [Accepted: 01/22/2025] [Indexed: 02/27/2025] Open
Abstract
Introduction: Transimpedance matrix measurement (TIM) is an electrophysiological measurement protocol of the impedance patterns of electrode contacts within the cochlea. Several studies have reported that TIM is an effective tool for the identification of abnormal electrode array placement. However, the normative values for properly inserted electrodes, as well as correlation of the TIM patterns with the electrode position, are not completely determined. Objectives: The first aim of this study is to establish normative values of TIM measurements obtained in children with proper electrode array insertion and tip fold-over, with proper inner ear anatomy and in congenital anomalies. The second aim of this study is to compare TIM measurements in Slim Modiolar (SM) and in Contour Advance (CA) electrodes, as their position is different according to the modiolus proximity. Methods: A total of 55 pediatric patients were included in the study and underwent cochlear implantation. 62 intraoperative measurements were conducted in this group-50 in children with normal inner ear anatomy and 12 in children with inner ear malformations. After each implantation, a plain x-ray was obtained. Results: There were clear statistically significant differences in TIM patterns in patients where electrode fold-over was confirmed and between SM and CA electrodes. Conclusions: TIM is a promising technique for intraoperative analysis of electrode placement. TIM patterns differ and correlate consistently with the different models of array implanted. This study is the first to report TIM patterns observed in children with normal inner ear anatomy and in inner ear malformations.
Collapse
Affiliation(s)
- Katarzyna Radomska
- Department of Otolaryngology, Pomeranian University of Medicine, ul. Unii Lubelskiej 1, 71-252 Szczecin, Poland
| | - Marcin Talar
- Department of Otolaryngology, Pomeranian University of Medicine, ul. Unii Lubelskiej 1, 71-252 Szczecin, Poland
- Medicus Sp. z o.o., pl. Strzelecki 24, 50-224 Wrocław, Poland
| | - Karolina Haber
- Pediatric Cochlear Implant Program, Department of Otolaryngology, Audiology and Phoniatrics, Children’s Hospital of Bydgoszcz, Ul. Chodkiewicza 44, 85-667 Bydgoszcz, Poland
- Department of Developmental Age Diseases, Nicolaus Copernicus University, 87-100 Torun, Poland
| | - Paulina Mierzwińska-Dolny
- Pediatric Cochlear Implant Program, Department of Otolaryngology, Audiology and Phoniatrics, Children’s Hospital of Bydgoszcz, Ul. Chodkiewicza 44, 85-667 Bydgoszcz, Poland
| | - Andrew J. Fishman
- Pediatric Cochlear Implant Program, Department of Otolaryngology, Audiology and Phoniatrics, Children’s Hospital of Bydgoszcz, Ul. Chodkiewicza 44, 85-667 Bydgoszcz, Poland
- Department of ORL, Military Medical Academy, 11000 Belgrade, Serbia
- Department of Otolaryngology, University of Missouri, Columbia, MO 65211, USA
| | - Józef Mierzwiński
- Pediatric Cochlear Implant Program, Department of Otolaryngology, Audiology and Phoniatrics, Children’s Hospital of Bydgoszcz, Ul. Chodkiewicza 44, 85-667 Bydgoszcz, Poland
- Department of Developmental Age Diseases, Nicolaus Copernicus University, 87-100 Torun, Poland
| |
Collapse
|
6
|
Tejani V, Piper R, Murray G, Manzoor NF, Mowry S, Semaan M, Rivas A. Sensitivity and Costs of Intraoperative Trans-Impedance Matrix Recordings, Spread of Excitation Functions, and X-ray Imaging in Detecting Cochlear Implant Tip Foldovers. Otol Neurotol 2024; 45:e763-e771. [PMID: 39514433 DOI: 10.1097/mao.0000000000004361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2024]
Abstract
OBJECTIVE Evaluate the sensitivity and financial costs of Trans-Impedance Matrix recordings, Spread of Excitation functions, and x-rays in detecting cochlear implant tip foldovers. SETTING Tertiary academic medical center. PATIENTS 113 ears of 108 patients. INTERVENTIONS Following cochlear implantation and before concluding surgery, intraoperative Trans-Impedance Matrix recordings, Spread of Excitation functions, and x-rays were conducted to evaluate presence of tip foldover. MAIN OUTCOME MEASURES Presence of tip foldover; recording time necessary for and costs of Trans-Impedance Matrix, spread of excitation, and x-rays. RESULTS There were six tip foldovers. Trans-Impedance Matrix showed 100% sensitivity, 100% specificity, 100% positive predictive value, and 100% negative predicative value in detecting tip foldovers. Spread of excitation showed 29% sensitivity, 99% specificity, 67% positive predictive value, and 95% negative predicative value. Trans-Impedance Matrix recordings were completed significantly faster than spread of excitation and x-rays. Elimination of x-rays from our intraoperative workflow results in a twofold cost reduction. CONCLUSION Trans-Impedance Matrix recordings have potential great clinical utility in evaluating proper CI placement intraoperatively and reducing costs of surgery while not compromising patient care. Given the low tip foldover rate, a multicenter study is in progress to evaluate the sensitivity, specificity, positive predictive value, and negative predicative value of Trans-Impedance Matrix in a larger dataset. This can provide better guidance to cochlear implant clinics interested in evaluating the impact of using Trans-Impedance Matrix on patient care as well as the economics of reducing use of intraoperative imaging.
Collapse
Affiliation(s)
| | | | | | - Nauman F Manzoor
- Department of Otolaryngology-Head and Neck Surgery, Virginia Commonwealth University, Richmond, Virginia
| | | | | | | |
Collapse
|
7
|
Teramura A, Kashio A, Sahara T, Koyama H, Kamogashira T, Urata S, Ueha R, Yamasoba T. Crista Fenestra Heights Measured by HRCT Predicts the Necessity for Extended Round Window Approach for Slim Modiolar Electrode. Otol Neurotol 2024; 45:e696-e699. [PMID: 39514422 DOI: 10.1097/mao.0000000000004335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2024]
Abstract
OBJECTIVE To evaluate the morphology of the crista fenestra (CF) using three-dimensional reconstruction based on high-resolution computed tomography (HRCT) and to examine the influence of CF height on the insertion approach used for CI632/532 implants. STUDY DESIGN Retrospective study. SETTING Tertiary referral center. PATIENTS Forty-five ears of 37 patients who received CI632/532 implants were included. INTERVENTIONS HRCT images were reconstructed into three-dimensional images, and CF structures were identified. The patients were divided into two group based on the insertion approach: round window approach (RW; n = 27) and extended round window approach (eRW; n = 18). To evaluate CF interference, 10 cases in the eRW group in which the sheath or electrode did not pass through the RW before widening the RW niche (nRW group) were specifically included in the analysis. MAIN OUTCOME MEASURE The identified CF cross-sections were confirmed by HRCT axial sectioning, and CF heights were measured. RESULTS The mean CF height was significantly greater in the nRW group than in the RW group (0.97 vs. 0.78 mm). CONCLUSION CF was identified using three-dimensional computer graphics (3DCG) and the CF height on the HRCT axial sections. Thus, measuring the CF height using 3DCG reconstruction can facilitate the preoperative selection of the electrode insertion approach.
Collapse
Affiliation(s)
- Atsumu Teramura
- Department of Otolaryngology and Head and Neck Surgery, University of Tokyo, Tokyo, Japan
| | - Akinori Kashio
- Department of Otolaryngology and Head and Neck Surgery, University of Tokyo, Tokyo, Japan
| | - Toshihito Sahara
- Department of Otolaryngology and Head and Neck Surgery, University of Tokyo, Tokyo, Japan
| | - Hajime Koyama
- Department of Otolaryngology and Head and Neck Surgery, University of Tokyo, Tokyo, Japan
| | - Teru Kamogashira
- Department of Otolaryngology and Head and Neck Surgery, University of Tokyo, Tokyo, Japan
| | - Shinji Urata
- Department of Otolaryngology and Head and Neck Surgery, University of Tokyo, Tokyo, Japan
| | | | | |
Collapse
|
8
|
Alzhrani F, Aljazeeri I, Abdelsamad Y, Alsanosi A, Kim AH, Ramos-Macias A, Ramos-de-Miguel A, Kurz A, Lorens A, Gantz B, Buchman CA, Távora-Vieira D, Sprinzl G, Mertens G, Saunders JE, Kosaner J, Telmesani LM, Lassaletta L, Bance M, Yousef M, Holcomb MA, Adunka O, Thomasen PC, Skarzynski PH, Rajeswaran R, Briggs RJ, Oh SH, Plontke S, O’Leary SJ, Agrawal S, Yamasoba T, Lenarz T, Wesarg T, Kutz W, Connolly P, Anderson I, Hagr A. International Consensus Statements on Intraoperative Testing for Cochlear Implantation Surgery. Ear Hear 2024; 45:1418-1426. [PMID: 38915137 PMCID: PMC11487033 DOI: 10.1097/aud.0000000000001526] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Accepted: 04/29/2024] [Indexed: 06/26/2024]
Abstract
OBJECTIVES A wide variety of intraoperative tests are available in cochlear implantation. However, no consensus exists on which tests constitute the minimum necessary battery. We assembled an international panel of clinical experts to develop, refine, and vote upon a set of core consensus statements. DESIGN A literature review was used to identify intraoperative tests currently used in the field and draft a set of provisional statements. For statement evaluation and refinement, we used a modified Delphi consensus panel structure. Multiple interactive rounds of voting, evaluation, and feedback were conducted to achieve convergence. RESULTS Twenty-nine provisional statements were included in the original draft. In the first voting round, consensus was reached on 15 statements. Of the 14 statements that did not reach consensus, 12 were revised based on feedback provided by the expert practitioners, and 2 were eliminated. In the second voting round, 10 of the 12 revised statements reached a consensus. The two statements which did not achieve consensus were further revised and subjected to a third voting round. However, both statements failed to achieve consensus in the third round. In addition, during the final revision, one more statement was decided to be deleted due to overlap with another modified statement. CONCLUSIONS A final core set of 24 consensus statements was generated, covering wide areas of intraoperative testing during CI surgery. These statements may provide utility as evidence-based guidelines to improve quality and achieve uniformity of surgical practice.
Collapse
Affiliation(s)
- Farid Alzhrani
- King Abdullah Ear Specialist Center (KAESC), College of Medicine, King Saud University Medical City, King Saud University, Riyadh, Saudi Arabia
| | - Isra Aljazeeri
- King Abdullah Ear Specialist Center (KAESC), College of Medicine, King Saud University Medical City, King Saud University, Riyadh, Saudi Arabia
- Aljaber Ophthalmology and Otolaryngology Specialized Hospital, Ministry of Health, Ahsa, Saudi Arabia
- Isra Aljazeeri shared first author
| | - Yassin Abdelsamad
- Research Department, Research Department, MED-EL GmbH, Riyadh, Saudi Arabia
| | - Abdulrahman Alsanosi
- King Abdullah Ear Specialist Center (KAESC), College of Medicine, King Saud University Medical City, King Saud University, Riyadh, Saudi Arabia
| | - Ana H. Kim
- Columbia University Medical Center, New York, New York, USA
| | - Angel Ramos-Macias
- Department of Otolaryngology and Head and Neck Surgery, University of Las Palmas de Gran Canaria, Las Palmas, Spain
| | - Angel Ramos-de-Miguel
- Department of Otolaryngology and Head and Neck Surgery, University of Las Palmas de Gran Canaria, Las Palmas, Spain
| | - Anja Kurz
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, Comprehensive Hearing Center, Würzburg, Germany
| | - Artur Lorens
- Word Hearing Center, Institute of Physiology and Pathology of Hearing, Warsaw/Kajetany, Poland
| | - Bruce Gantz
- Department of Otolaryngology—Head and Neck Surgery/Neurosurgery, University of Iowa Hospitals and Clinics, University of Iowa, Iowa City, Iowa, USA
| | - Craig A. Buchman
- Department of Otolaryngology-Head & Neck Surgery, Washington University in St. Louis, St. Louis, MO
| | - Dayse Távora-Vieira
- Division of Surgery, Medical School, The University of Western Australia, Perth, Western Australia, Australia
- Department of Audiology, Fiona Stanley Fremantle Hospitals Group, Perth, Western Australia, Australia
- School of Population Health, Curtin University, Perth, Western Australia, Australia
| | - Georg Sprinzl
- Department of Otorhinolaryngology, Karl Landsteiner University of Health Sciences, University Hospital St. Poelten, St. Poelten, Austria
| | - Griet Mertens
- Department of Otorhinolaryngology, Head and Neck Surgery, Antwerp University Hospital, Antwerp, Belgium
- Faculty of Medicine and Health Sciences, Experimental Laboratory of Translational Neurosciences and Dento-Otolaryngology, University of Antwerp, Antwerp, Belgium
| | - James E. Saunders
- Section of Otolaryngology-Head and Neck Surgery, Department of Surgery, Dartmouth-Hitchcock Medical Center, Geisel School of Medicine at Dartmouth, New Hampshire, USA
| | - Julie Kosaner
- Meders Speech and Hearing Clinic, Meders İşitme ve Konuşma Merkezi, İstanbul, Turkey
| | - Laila M. Telmesani
- Department of Otolaryngology/Head and Neck Surgery, College of Medicine, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Luis Lassaletta
- Department of Otorhinolaryngology, Hospital La Paz, IdiPAZ Research Institute, Madrid, Spain
- Biomedical Research Networking Centre on Rare Diseases, Institute of Health Carlos III, Madrid, Spain
| | - Manohar Bance
- Department of Otolaryngology-Head and Neck Surgery, Addenbrooke’s Hospital, University of Cambridge, United Kingdom
| | - Medhat Yousef
- King Abdullah Ear Specialist Center (KAESC), College of Medicine, King Saud University Medical City, King Saud University, Riyadh, Saudi Arabia
- Audiology Unit, ENT Department, Menoufia University, Menoufia, Egypt
| | - Meredith A. Holcomb
- Hearing Implant Program, Department of Otolaryngology, University of Miami, Miami, Florida, USA
| | - Oliver Adunka
- Ohio State University Wexner Medical Center, The Ohio State University, Columbus, Ohio, USA
| | - Per Cayé- Thomasen
- Department of Otorhinolaryngology, Head and Neck Surgery and Audiology, Rigshospitalet, Denmark
| | - Piotr H. Skarzynski
- Department of Teleaudiology and Screening, World Hearing Center, Institute of Physiology and Pathology of Hearing, Warsaw, Poland
- Faculty of Dental Medicine, Heart Failure and Cardiac Rehabilitation Department, Medical University of Warsaw, Warsaw, Poland
- Institute of Sensory Organs, Nadarzyn/Kajetany, Poland
- Center of Hearing and Speech “Medincus,” Nadarzyn/Kajetany, Poland
| | - Ranjith Rajeswaran
- Madras ENT Research Foundation MERF Institute of Speech and Hearing, Chennai, India
| | - Robert J. Briggs
- Department of Surgery, Otolaryngology, The University of Melbourne, The Royal Victorian Eye and Ear Hospital, East Melbourne, Victoria, Australia
| | - Seung-Ha Oh
- Department of Otorhinolaryngology, Seoul National University College of Medicine, Seoul, Korea
| | - Stefan Plontke
- Department of Otorhinolaryngology, Head and Neck Surgery; Martin Luther University Halle-Wittenberg, Halle (Saale), Germany
| | - Stephen J. O’Leary
- Department of Surgery, Otolaryngology, The University of Melbourne, The Royal Victorian Eye and Ear Hospital, East Melbourne, Victoria, Australia
| | - Sumit Agrawal
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, Ontario, Canada
- Department of Electrical and Computer Engineering, School of Biomedical Engineering, Western University, London, Ontario, Canada
| | - Tatsuya Yamasoba
- Tokyo Teishin Hospital, Tokyo, Japan
- Department of Otolaryngology and Head and Neck Surgery, University of Tokyo, Tokyo, Japan
| | - Thomas Lenarz
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medical School, Hanover, Germany
| | - Thomas Wesarg
- Department of Otorhinolaryngology-Head and Neck Surgery, Medical Center–University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg im Breisgau, Germany
| | - Walter Kutz
- Department of Otolaryngology-Head and Neck Surgery, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | | | - Ilona Anderson
- Clinical Research Department, MED-EL GmbH, Innsbruck, Austria
| | - Abdulrahman Hagr
- King Abdullah Ear Specialist Center (KAESC), College of Medicine, King Saud University Medical City, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
9
|
Kopsch AC, Wagner L, Plontke SK, Kösling S. A Case Series Suggests Peaking Transimpedance as a Possible Marker for Scalar Dislocations in Cochlear Implantation. Audiol Neurootol 2024; 30:187-196. [PMID: 39462500 DOI: 10.1159/000541954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2024] [Accepted: 09/26/2024] [Indexed: 10/29/2024] Open
Abstract
INTRODUCTION During postoperative implant control, we observed extraordinary peaks in transimpedance measurements. While searching for a possible reason, it appeared that they might correlate with scalar dislocations. METHODS In this retrospective case series, six adult CI patients who underwent transimpedance measurements and postoperative imaging were analyzed. Intra- and postoperative transimpedance measurements were visual inspected. The intracochlear position of electrodes was radiologically identified. RESULTS From 6 patients with transimpedance matrices showing an extraordinary peak in the off-diagonal area, five electrode arrays showed no correct scalar localization in the scala tympani, and one had a correct scalar localization in the scala tympani. CONCLUSIONS A peaking transimpedance might be a marker for scalar dislocation in CIs.
Collapse
Affiliation(s)
- Anna C Kopsch
- Department of Otorhinolaryngology, Head and Neck Surgery, Martin Luther University Halle-Wittenberg, University Medicine Halle, Halle, Germany
| | - Luise Wagner
- Department of Otorhinolaryngology, Head and Neck Surgery, Martin Luther University Halle-Wittenberg, University Medicine Halle, Halle, Germany
| | - Stefan K Plontke
- Department of Otorhinolaryngology, Head and Neck Surgery, Martin Luther University Halle-Wittenberg, University Medicine Halle, Halle, Germany
| | - Sabrina Kösling
- Department of Radiology, Martin Luther University Halle-Wittenberg, University Medicine Halle, Halle, Germany
| |
Collapse
|
10
|
Jiam NT, Podury A, Quesnel AM, Handzel O. Worldwide differences in surgeon intraoperative practices for cochlear implantation. Cochlear Implants Int 2024; 25:344-351. [PMID: 38935802 DOI: 10.1080/14670100.2024.2367309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/29/2024]
Abstract
OBJECTIVE To characterize practice patterns of intraoperative imaging and/or functional confirmation of cochlear implant electrode location worldwide. METHODS A cross-sectional survey of otolaryngologists performing cochlear implantation was conducted between March 1 and May 6, 2023. Participants were recruited worldwide using an international otologic society membership email list and at professional meetings. Ninety-seven of the 125 invited participants (78%) completed the survey. Participants were categorized by continent. RESULTS North American surgeons use intraoperative X-rays more frequently than surgeons in Europe and Asia (p < 0.001). Otolaryngologists in Europe and Asia more frequently use no intraoperative imaging (p = 0.02). There is no regional difference between the intraoperative use of electrophysiologic instruments. European and Asian surgeons implant MED-EL devices (p = 0.012) more frequently than North American surgeons, who more frequently use Cochlear Corporation devices (p = 0.003). MED-EL use is related to less frequent intraoperative X-ray use (p = 0.02). Advanced Bionics use is related to more frequent intraoperative CT use (p = 0.03). No significant association existed between years of practice, number of cochlear implantation surgeries performed yearly, volume of pediatric CI practice, and use of intraoperative tools. CONCLUSION Intraoperative practice for radiologic and functional verification of cochlear implant electrode positioning varies worldwide. Practice guidelines may help establish a standard of care for cochlear implantation.
Collapse
Affiliation(s)
- Nicole T Jiam
- Department of Otolaryngology-Head & Neck Surgery, Massachusetts Eye and Ear, Boston, MA, USA
- Department of Otolaryngology-Head & Neck Surgery, University of California - San Francisco, San Francisco, CA, USA
| | - Archana Podury
- Department of Otolaryngology, University of California - San Diego, San Diego, CA, USA
| | - Alicia M Quesnel
- Department of Otolaryngology-Head & Neck Surgery, Massachusetts Eye and Ear, Boston, MA, USA
| | - Ophir Handzel
- Department of Otolaryngology-Head & Neck Surgery, Massachusetts Eye and Ear, Boston, MA, USA
- Department of Otolaryngology-Head & Neck Surgery, Tel-Aviv Sourasky Medical Center, Tel-Aviv University, Tel Aviv-Yafo, Israel
| |
Collapse
|
11
|
Berg KA, DeFreese AJ, Sisler-Dinwiddie AL, Labadie RF, Tawfik KO, Gifford RH. Clinical Applications for Spread of Excitation Functions Obtained Via Electrically Evoked Compound Action Potentials (eCAP). Otol Neurotol 2024; 45:790-797. [PMID: 38923968 DOI: 10.1097/mao.0000000000004242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/28/2024]
Abstract
OBJECTIVES To assess the clinical utility of spread of excitation (SOE) functions obtained via electrically evoked compound action potentials (eCAP) to 1) identify electrode array tip fold-over, 2) predict electrode placement factors confirmed via postoperative computed tomography (CT) imaging, and 3) predict postoperative speech recognition through the first year post-activation in a large clinical sample. STUDY DESIGN Retrospective case review. SETTING Cochlear implant (CI) program at a tertiary medical center. PATIENTS Two hundred seventy-two ears (238 patients) with Cochlear Ltd. CIs (mean age = 46 yr, range = 9 mo-93 yr, 50% female) implanted between August 2014 and December 2022 were included. MAIN OUTCOME MEASURES eCAP SOE widths (mm) (probe electrodes 5, 11, and 17), incidence of electrode tip fold-over, CT imaging data (electrode-to-modiolus distance, angular insertion depth, scalar location), and speech recognition outcomes (consonant-nucleus-consonant [CNC], AzBio quiet, and +5 dB SNR) through the first year after CI activation. RESULTS 1) eCAP SOE demonstrated a sensitivity of 85.7% for identifying tip fold-over instances that were confirmed by CT imaging. In the current dataset, the tip fold-over incidence rate was 3.1% (7 patients), with all instances involving a precurved electrode array. 2) There was a significant positive relationship between eCAP SOE and mean electrode-to-modiolus distance for precurved arrays, and a significant positive relationship between eCAP SOE and angular insertion depth for straight arrays. No relationships between eCAP SOE and scalar location or cochlea diameter were found in this sample. 3) There were no significant relationships between eCAP SOE and speech recognition outcomes for any measure or time point, except for a weak negative correlation between average eCAP SOE widths and CNC word scores at 6 months post-activation for precurved arrays. CONCLUSIONS In the absence of intraoperative CT or fluoroscopic imaging, eCAP SOE is a reasonable alternative method for identifying electrode array tip fold-over and should be routinely measured intraoperatively, especially for precurved electrode arrays with a sheath.
Collapse
Affiliation(s)
- Katelyn A Berg
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Andrea J DeFreese
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
| | | | - Robert F Labadie
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, Charleston, South Carolina
| | | | - René H Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
| |
Collapse
|
12
|
Goffi-Gomez MVS, Corrêa FMDS, Magalhães AT, Hoshino AC, Samuel P, Sadowski T, Colalto C, Tsuji RK, Brito Neto R. Is the spread of excitation different between adults and children cochlear implants users? Eur Arch Otorhinolaryngol 2024; 281:3491-3498. [PMID: 38240771 DOI: 10.1007/s00405-024-08451-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Accepted: 01/02/2024] [Indexed: 06/29/2024]
Abstract
PURPOSE While cochlea is adult size at birth, etiologies and bone density may differ between children and adults. Differences in neural response thresholds (tNRT) and the spread of excitation (SOE) width may impact the use of artificial intelligence algorithms in speech processor fitting. AIM To identify whether neural response telemetry threshold and spread of excitation width are similar in adults and children. METHODS Retrospective cross-sectional study approved by the Ethical Board. Intraoperative tNRT and SOE recordings of consecutive cochlear implant surgeries in adults and children implanted with Cochlear devices (Cochlear™, Australia) were selected. SOE was recorded on electrode 11 (or adjacent, corresponding to the medial region of the cochlea) through the standard forward-masking technique in Custom Sound EP software, which provides SOE width in millimeters. Statistical comparison between adults and children was performed using the Mann-Whitney test (p ≤ 0.05). RESULTS Of 1282 recordings of intraoperative evaluations, 414 measurements were selected from children and adults. Despite the tNRT being similar between adults and children, SOE width was significantly different, with lower values in children with perimodiolar arrays. Besides, it was observed that there is a difference in the electrode where the SOE function peak occurred, more frequently shifted to electrode 12 in adults implanted. In straight arrays, there was no difference in any of the parameters analyzed on electrode 11. CONCLUSION Although eCAP thresholds are similar, SOE measurements differ between adults and children in perimodiolar electrodes.
Collapse
Affiliation(s)
- Maria Valéria Schmidt Goffi-Gomez
- ENT Department, Cochlear Implant Group at Clinical Hospital of the Medical School at University of São Paulo, Av. Dr. Eneas de Carvalho Aguiar 255, São Paulo, Brazil.
| | - Francyelle Machado da Silva Corrêa
- ENT Department, Cochlear Implant Group at Clinical Hospital of the Medical School at University of São Paulo, Av. Dr. Eneas de Carvalho Aguiar 255, São Paulo, Brazil
| | - Ana Tereza Magalhães
- ENT Department, Cochlear Implant Group at Clinical Hospital of the Medical School at University of São Paulo, Av. Dr. Eneas de Carvalho Aguiar 255, São Paulo, Brazil
| | - Ana Cristina Hoshino
- ENT Department, Cochlear Implant Group at Clinical Hospital of the Medical School at University of São Paulo, Av. Dr. Eneas de Carvalho Aguiar 255, São Paulo, Brazil
| | - Paola Samuel
- ENT Department, Cochlear Implant Group at Clinical Hospital of the Medical School at University of São Paulo, Av. Dr. Eneas de Carvalho Aguiar 255, São Paulo, Brazil
| | - Tatiana Sadowski
- ENT Department, Cochlear Implant Group at Clinical Hospital of the Medical School at University of São Paulo, Av. Dr. Eneas de Carvalho Aguiar 255, São Paulo, Brazil
| | - Claudia Colalto
- ENT Department, Cochlear Implant Group at Clinical Hospital of the Medical School at University of São Paulo, Av. Dr. Eneas de Carvalho Aguiar 255, São Paulo, Brazil
| | - Robinson Koji Tsuji
- ENT Department, Cochlear Implant Group at Clinical Hospital of the Medical School at University of São Paulo, Av. Dr. Eneas de Carvalho Aguiar 255, São Paulo, Brazil
| | - Rubens Brito Neto
- ENT Department, Cochlear Implant Group at Clinical Hospital of the Medical School at University of São Paulo, Av. Dr. Eneas de Carvalho Aguiar 255, São Paulo, Brazil
| |
Collapse
|
13
|
Burck I, Yel I, Martin S, Albrecht MH, Koch V, Booz C, Pinto Dos Santos D, Kaltenbach B, Ackermann H, Koivisto J, Helbig S, Stöver T, Vogl TJ, Scholtz JE. Comparison of 96-kV and 120-kV cone-beam CT for the assessment of cochlear implants. BMC Med Imaging 2024; 24:145. [PMID: 38872126 PMCID: PMC11177440 DOI: 10.1186/s12880-024-01322-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Accepted: 06/04/2024] [Indexed: 06/15/2024] Open
Abstract
BACKGROUND To compare the diagnostic value of 120-kV with conventional 96-kV Cone-Beam CT (CBCT) of the temporal bone after cochlear implant (CI) surgery. METHODS This retrospective study included CBCT scans after CI surgery between 06/17 and 01/18. CBCT allowed examinations with 96-kV or 120-kV; other parameters were the same. Two radiologists independently evaluated following criteria on 5-point Likert scales: osseous spiral lamina, inner and outer cochlear wall, semi-circular canals, mastoid trabecular structure, overall image quality, metal and motion artefacts, depiction of intracochlear electrode position and visualisation of single electrode contacts. Effective radiation dose was assessed. RESULTS Seventy-five patients (females, n = 39 [52.0%], mean age, 55.8 ± 16.5 years) were scanned with 96-kV (n = 32, 42.7%) and 120-kV (n = 43, 57.3%) protocols including CI models from three vendors (vendor A n = 7; vendor B n = 43; vendor C n = 25). Overall image quality, depiction of anatomical structures, and electrode position were rated significantly better in 120-kV images compared to 96-kV (all p < = 0.018). Anatomical structures and electrode position were rated significantly better in 120-kV CBCT for CI models from vendor A and C, while 120-kV did not provide improved image quality in CI models from vendor B. Radiation doses were significantly higher for 120-kV scans compared to 96-kV (0.15 vs. 0.08 mSv, p < 0.001). CONCLUSIONS 120-kV and 96-kV CBCT provide good diagnostic images for the postoperative CI evaluation. While 120-kV showed improved depiction of temporal bone and CI electrode position compared to 96-kV in most CI models, the 120-kV protocol should be chosen wisely due to a substantially higher radiation exposure.
Collapse
Affiliation(s)
- Iris Burck
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany.
| | - Ibrahim Yel
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Simon Martin
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Moritz H Albrecht
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Vitali Koch
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Christian Booz
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Daniel Pinto Dos Santos
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Benjamin Kaltenbach
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Hanns Ackermann
- Institute of Biostatistics and Mathematical Modeling, University Hospital Frankfurt, Frankfurt, Germany
- Department of Otorhinolaryngology, University Hospital Frankfurt, Frankfurt, Germany
| | | | - Silke Helbig
- Department of Otorhinolaryngology, University Hospital Frankfurt, Frankfurt, Germany
| | - Timo Stöver
- Department of Otorhinolaryngology, University Hospital Frankfurt, Frankfurt, Germany
| | - Thomas J Vogl
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Jan-Erik Scholtz
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| |
Collapse
|
14
|
Zhang L, Schmidt FH, Oberhoffner T, Ehrt K, Cantré D, Großmann W, Schraven SP, Mlynski R. Transimpedance Matrix Can Be Used to Estimate Electrode Positions Intraoperatively and to Monitor Their Positional Changes Postoperatively in Cochlear Implant Patients. Otol Neurotol 2024; 45:e289-e296. [PMID: 38346796 DOI: 10.1097/mao.0000000000004145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/14/2024]
Abstract
OBJECTIVE Accurate positioning of the electrode array during cochlear implant (CI) surgery is crucial for achieving optimal hearing outcomes. Traditionally, postoperative radiological imaging has been used to assess electrode position. Transimpedance matrix (TIM) measurements have also emerged as a promising method for assessing electrode position. This involves utilizing electric field imaging to create an electric distance matrix by analyzing voltage variations among adjacent electrodes. This study aimed to investigate the feasibility of using intraoperative TIM measurements to estimate electrode position and monitor postoperative changes. STUDY DESIGN Retrospective cohort study. SETTING University Medical center, tertiary academic referral center. PATIENTS Patients undergoing CI (CI622) surgery between January 2019 and June 2022. INTERVENTION CI electrode positions and maximal angular insertion depths (maxAID) were determined using X-ray imaging according to Stenvers' projection. The mean gradient phase (MGP) was extracted from the TIM, and a correlation between the MGP and maxAID was examined. A model was then built to estimate the maxAID using the MGP, and changes in electrode location over time were assessed using this model. MAIN OUTCOME MEASURES Twenty-four patients were included in this study. A positive correlation between the maxAID and the MGP ( R = 0.7, p = 0.0001) was found. The established model was able to predict the maxAID with an accuracy of 27.7 ± 4.4°. Comparing intraoperative and postoperative TIM measurements, a decrease of 24.1° ± 10.7° in maxAID over time was observed. CONCLUSION TIM measurements are useful for estimating the insertion depth of the electrode and monitoring changes in the electrode's position over time.
Collapse
Affiliation(s)
- Lichun Zhang
- Departments of Otorhinolaryngology, Head and Neck Surgery, "Otto Körner,"
| | | | - Tobias Oberhoffner
- Departments of Otorhinolaryngology, Head and Neck Surgery, "Otto Körner,"
| | - Karsten Ehrt
- Departments of Otorhinolaryngology, Head and Neck Surgery, "Otto Körner,"
| | - Daniel Cantré
- Radiology, Rostock University Medical Center, Rostock, Germany
| | - Wilma Großmann
- Departments of Otorhinolaryngology, Head and Neck Surgery, "Otto Körner,"
| | | | - Robert Mlynski
- Departments of Otorhinolaryngology, Head and Neck Surgery, "Otto Körner,"
| |
Collapse
|
15
|
Ayas M, Muzaffar J, Borsetto D, Eitutis S, Phillips V, Tam YC, Salorio-Corbetto M, Bance ML. A scoping review on the clinical effectiveness of Trans-Impedance Matrix (TIM) measurements in detecting extracochlear electrodes and tip fold overs in Cochlear Ltd devices. PLoS One 2024; 19:e0299597. [PMID: 38452034 PMCID: PMC10919746 DOI: 10.1371/journal.pone.0299597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Accepted: 02/12/2024] [Indexed: 03/09/2024] Open
Abstract
BACKGROUND Extrusion of electrodes outside the cochlea and tip fold overs may lead to suboptimal outcomes in cochlear implant (CI) recipients. Intraoperative measures such as Trans-Impedance Matrix (TIM) measurements may enable clinicians to identify electrode malposition and direct surgeons to correctly place the electrode array during surgery. OBJECTIVES To assess the current literature on the effectiveness of TIM measurements in identifying extracochlear electrodes and tip fold overs. METHODS A scoping review of studies on TIM-based measurements were carried out using the Databases-Medline/PubMed, AMED, EMBASE, CINAHL and the Cochrane Library following PRISMA guidelines. Eleven full texts articles met the inclusion criteria. Only human studies pertaining to TIM as a tool used in CI were included in the review. Further, patient characteristics, electrode design, and TIM measurement outcomes were reported. RESULTS TIM measurements were available for 550 implanted ears with the subjects age ranged between 9 months to 89 years. Abnormal TIM measurements were reported for 6.55% (36). Tip fold over was detected in 3.64% (20) of the cases, extracochlear electrodes in 1.45% (8), and 1.45% (8) were reported as buckling. Slim-modiolar electrode array designs were more common (54.71%) than pre-curved (23.34%) or lateral wall (21.95%) electrode array. Abnormal cochlear anatomy was reported for five ears (0.89%), with normal cochlear anatomy for all other patients. CONCLUSION TIM measurement is a promising tool for the intraoperative detection of electrode malposition. TIM measurement has a potential to replace intraoperative imaging in future. Though, TIM measurement is in its early stages of clinical utility, intuitive normative data sets coupled with standardised criteria for detection of abnormal electrode positioning would enhance its sensitivity.
Collapse
Affiliation(s)
- Muhammed Ayas
- College of Health Sciences, University of Sharjah, Sharjah, United Arab Emirates
- Emmeline Centre, Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom
- Cambridge Hearing Group, University of Cambridge, Cambridge, United Kingdom
| | - Jameel Muzaffar
- Cambridge Hearing Group, University of Cambridge, Cambridge, United Kingdom
- Department of Ear, Nose and Throat Surgery, University Hospitals Birmingham NHS Foundation Trust, Birmingham, United Kingdom
| | - Daniele Borsetto
- Cambridge Hearing Group, University of Cambridge, Cambridge, United Kingdom
- Department of ENT, Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom
| | - Susan Eitutis
- Emmeline Centre, Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom
- Cambridge Hearing Group, University of Cambridge, Cambridge, United Kingdom
| | - Veronica Phillips
- Medical Library, University of Cambridge School of Clinical Medicine, Cambridge, United Kingdom
| | - Yu Chuen Tam
- Emmeline Centre, Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom
- Cambridge Hearing Group, University of Cambridge, Cambridge, United Kingdom
| | - Marina Salorio-Corbetto
- Emmeline Centre, Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom
- Cambridge Hearing Group, University of Cambridge, Cambridge, United Kingdom
| | - Manohar L. Bance
- Cambridge Hearing Group, University of Cambridge, Cambridge, United Kingdom
- Department of ENT, Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom
| |
Collapse
|
16
|
Beck R, Aschendorff A, Arndt S, Hildenbrand T, Rauch AK, Ketterer MC. Evaluation of insertion quality of a slim perimodiolar electrode array. Eur Arch Otorhinolaryngol 2024; 281:1215-1220. [PMID: 37773530 PMCID: PMC10858093 DOI: 10.1007/s00405-023-08212-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Accepted: 08/25/2023] [Indexed: 10/01/2023]
Abstract
OBJECTIVES The influence of cochlear morphology and electrode array design on scalar position and dislocation rates is of great interest in CI surgery. The aim of this study is to evaluate scalar position and specific points of dislocation in relation to cochlear morphology in patients implanted with a new slim perimodiolar electrode array. MATERIALS AND METHODS Patients were implanted using the slim modiolar electrode array (= SMA) (= 532/632 electrode array of Cochlear™). Postoperative imaging was performed via cone beam computed tomography (CBCT) and the scans were analyzed regarding cochlear morphology (distances A and B and cochlear height), scalar location of the electrode array, basal insertion depth and apical insertion angle. Furthermore, electrode array design and surgical protocols were evaluated. RESULTS 81 ears implanted with the SMA were retrospectively included. We evaluated 3 electrode array tip fold over intraoperatively via X-ray imaging and performed revision during the same surgery. The CBCT scans showed 76 initial scala tympani (ST) insertions without dislocation. Two ears showed a dislocated array, one at 77° and the other at 163°. Three arrays were inserted into scala vestibuli (SV) via cochleostomy. These patients showed no signs of obliteration. Cochlear morphology showed no influence on angular insertion depth and scalar position. CONCLUSIONS The SMA showed a very low rate of scalar dislocations due to its slim electrode array design (2.7%). We could find a learning curve regarding the handling and the risk of dislocation and tip fold over with this electrode array. The rate of intraoperative tip fold over detection via X-ray imaging was 3.7%. Therefore, we highly recommend X-ray imaging and transimpedance matrix measurements within the surgery protocol. Scala vestibuli insertions happened in patients with cochleostomy only. We could identify two specific points of dislocation depending on electrode array design.
Collapse
Affiliation(s)
- R Beck
- Faculty of Medicine, Department of Otorhinolaryngology, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | - A Aschendorff
- Faculty of Medicine, Department of Otorhinolaryngology, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | - S Arndt
- Faculty of Medicine, Department of Otorhinolaryngology, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | - T Hildenbrand
- Faculty of Medicine, Department of Otorhinolaryngology, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | - A K Rauch
- Faculty of Medicine, Department of Otorhinolaryngology, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | - M C Ketterer
- Faculty of Medicine, Department of Otorhinolaryngology, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany.
- Department of Otorhinolaryngology - Head and Neck Surgery, University of Freiburg, Killianstrasse 5, 79106, Freiburg, Germany.
| |
Collapse
|
17
|
Song B, Oh S, Kim D, Cho YS, Moon IJ. Changes in Revision Cochlear Implantation and Device Failure Profiles. Clin Exp Otorhinolaryngol 2024; 17:37-45. [PMID: 38228133 PMCID: PMC10933811 DOI: 10.21053/ceo.2023.00010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 11/10/2023] [Accepted: 12/27/2023] [Indexed: 01/18/2024] Open
Abstract
OBJECTIVES As cochlear implantation (CI) experiences rapid innovations and its indications expand, the characteristics of revision CI (RCI) are evolving. This study investigated changes in the RCI profile and explored their clinical implications. METHODS A retrospective chart review was conducted of all CIs performed at a tertiary medical institution between October 2001 and January 2023. The rates of and reasons for RCI were evaluated in relation to the manufacturer and device model. Kaplan-Meier analysis was employed to examine cumulative and device survival curves. Cumulative and device survival rates were additionally analyzed based on age group, period of primary CI, and manufacturer. A Cox proportional hazards model was employed to evaluate the association between RCI and the device manufacturer. RESULTS Among 1,430 CIs, 73 (5.1%) required RCI. The predominant reason for RCI was device failure (40 of 73 RCIs [54.8%]), with an overall device failure rate of 2.8%. This was followed by flap-associated problems and migration (nine of 73 RCIs each [12.3%]). Flap retention issues emerged as a new cause in three cases (two involving the CI 632 and one involving the SYNCHRONY 2 implant), and six instances of electrode tip fold-over arose (four for the CI 600 series and two for the CI 500 series). The overall 10-year cumulative and device survival rates were 93.4% and 95.8%, respectively. After excluding models with recall issues, significant differences in cumulative (P =0.010) and device (P =0.001) survival rates were observed across manufacturers. CONCLUSION While the overall CI survival rate is stable, device failure persists as the predominant reason for RCI. Moreover, the types of complications leading to revision (including issues with flap retention and electrode tip fold-over) have shifted, particularly for newer implant models. Given the clinical importance of device failure and subsequent reoperation, clinicians should remain informed about and responsive to these trends.
Collapse
Affiliation(s)
- Bokhyun Song
- Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Subi Oh
- Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Doyun Kim
- Hearing Research Laboratory, Samsung Medical Center, Seoul, Korea
| | - Young Sang Cho
- Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
- Hearing Research Laboratory, Samsung Medical Center, Seoul, Korea
| | - Il Joon Moon
- Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
- Hearing Research Laboratory, Samsung Medical Center, Seoul, Korea
| |
Collapse
|
18
|
Oh H, Kim Y, Lee SJ, Carandang M, Song JJ, Choi BY. Two Discrete Types of Tip Fold-Over in Cochlear Implantation Using Slim Modiolar Electrodes: Influence of Cochlear Duct Length on Tip Fold-Over. Otol Neurotol 2023; 44:1011-1014. [PMID: 37733985 DOI: 10.1097/mao.0000000000004022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/23/2023]
Abstract
OBJECTIVE Precise electrode positioning is crucial for achieving optimal audiological outcomes in cochlear implantation. The slim modiolar electrode (SME), a thin, flexible, and precurved electrode, exhibits favorable modiolar proximity. However, tip fold-over can affect optimal electrode placement. Herein, we share our experiences with tip fold-over in SMEs and present an analysis of conditions that may predispose to tip fold-over. STUDY DESIGN Retrospective medical record review. PATIENTS In total, 475 patients (671 ears) underwent cochlear implantation using SMEs (Nucleus CI532 or CI632 from Cochlear) performed by a single surgeon at a tertiary center between June 14, 2018, and December 1, 2022. INTERVENTIONS Intraoperative x-ray scans (cochlear view), operative records, and cochlear duct length (CDL) were reviewed. MAIN OUTCOME MEASURES Tip fold-over patterns on plain x-ray images (proximal versus distal). RESULTS Electrode tip fold-over was observed in 18 (2.7%) of the 671 ears with SMEs. This fold-over occurred more frequently in cases with long CDL (>36 mm). Among the 14 cases with available initial x-rays before correction of the tip fold-over, half were classified as proximal and the other half as distal. A predilection for proximal tip fold-over was found in those with a CDL of 36 mm or longer, and longer CDLs were observed for proximal cases than for distal cases. Our pilot data suggest that identifying the type of tip fold-over can aid in correcting it more efficiently. CONCLUSIONS Tip fold-over of SME does not occur uniformly and is more common in ears with long CDL. This tendency is particularly pronounced for the proximal type of tip fold-over. Therefore, preoperative measurement of the CDL and meticulous examination of intraoperative imaging are essential for customized correction.
Collapse
Affiliation(s)
- Heonjeong Oh
- Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
| | - Yehree Kim
- Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
| | - Seung Jae Lee
- Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
| | - Marge Carandang
- Department of Otorhinolaryngology-Head and Neck Surgery, Department of Otorhinolaryngology-Head and Neck Surgery, Tondo Medical Center, Metro Manila, Philippines
| | | | | |
Collapse
|
19
|
Weller T, Timm ME, Lenarz T, Büchner A. Cochlear coverage with lateral wall cochlear implant electrode arrays affects post-operative speech recognition. PLoS One 2023; 18:e0287450. [PMID: 37437046 DOI: 10.1371/journal.pone.0287450] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Accepted: 06/06/2023] [Indexed: 07/14/2023] Open
Abstract
OBJECTIVES The goal was to investigate the relationship between the insertion angle/cochlear coverage of cochlear implant electrode arrays and post-operative speech recognition scores in a large cohort of patients implanted with lateral wall electrode arrays. METHODS Pre- and post-operative cone beam computed tomography scans of 154 ears implanted with lateral wall electrode arrays were evaluated. Traces of lateral wall and electrode arrays were combined into a virtual reconstruction of the implanted cochlea. This reconstruction was used to measure insertion angles and proportional cochlear coverage. Word recognition scores and sentence recognition scores measured 12 months after implantation using electric-only stimulation were used to examine the relationship between cochlear coverage/insertion angle and implantation outcomes. RESULTS Post-operative word recognition scores and the difference between post- and pre-operative word recognition scores were positively correlated with both cochlear coverage and insertion angle, however sentence recognition scores were not. A group-wise comparison of word recognition scores revealed that patients with cochlear coverage below 70% performed significantly worse than patients with coverage between 79%-82% (p = 0.003). Performance of patients with coverage above 82% was on average poorer than between 79%-82, although this finding was not statistically significant (p = 0.84). Dividing the cohort into groups based on insertion angle quadrants revealed that word recognition scores were highest above 450° insertion angle, sentence recognition scores were highest between 450° and 630° and the difference between pre- and post-operative word recognition scores was largest between 540° and 630°, however none of these differences reached statistical significance. CONCLUSIONS The results of this study show that cochlear coverage has an effect on post-operative word recognition abilities and the benefit patients receive from their implant. Generally, higher coverage led to better outcomes, however there were results indicating that insertion past 82% cochlear coverage may not provide an additional benefit for word recognition. These findings can be useful for choosing the optimal electrode array and thereby improving cochlear implantation outcomes on a patient-individual basis.
Collapse
Affiliation(s)
- Tobias Weller
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- German Hearing Center (DHZ), Hannover, Germany
- Cluster of Excellence "Hearing4All", Oldenburg, Germany
| | - Max Eike Timm
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
| | - Thomas Lenarz
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- German Hearing Center (DHZ), Hannover, Germany
- Cluster of Excellence "Hearing4All", Oldenburg, Germany
| | - Andreas Büchner
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- German Hearing Center (DHZ), Hannover, Germany
- Cluster of Excellence "Hearing4All", Oldenburg, Germany
| |
Collapse
|
20
|
Söderqvist S, Sivonen V, Koivisto J, Aarnisalo A, Sinkkonen ST. Spread of the intracochlear electrical field: Implications for assessing electrode array location in cochlear implantation. Hear Res 2023; 434:108790. [PMID: 37196460 DOI: 10.1016/j.heares.2023.108790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 05/03/2023] [Accepted: 05/10/2023] [Indexed: 05/19/2023]
Abstract
The electrode-generated intracochlear electrical field (EF) spreads widely along the scala tympani surrounded by poorly-conducting tissue and it can be measured with monopolar transimpedance matrix (TIMmp). Bipolar TIM (TIMbp) allows estimations of local potential differences. With TIMmp, the correct alignment of the electrode array can be assessed, and TIMbp may be useful in more subtle evaluations of the electrode array's intracochlear location. In this temporal bone study, we investigated the effect of the cross-sectional scala area (SA) and the electrode-medial-wall distance (EMWD) on both TIMmp and TIMbp using three types of electrode arrays. Also, multiple linear regressions based on the TIMmp and TIMbp measurements were used to estimate the SA and EMWD. Six cadaver temporal bones were consecutively implanted with a lateral-wall electrode array (Slim Straight) and with two different precurved perimodiolar electrode arrays (Contour Advance and Slim Modiolar) for variation in EMWD. The bones were imaged with cone-beam computed tomography with simultaneous TIMmp and TIMbp measurements. The results from imaging and EF measurements were compared. SA increased from apical to basal direction (r = 0.96, p < 0.001). Intracochlear EF peak negatively correlated with SA (r = -0.55, p < 0.001) irrespective of the EMWD. The rate of the EF decay did not correlate with SA but it was faster in the proximity of the medial wall than in more lateral positions (r = 0.35, p < 0.001). For a linear comparison between the EF decaying proportionally to squared distance and anatomic dimensions, a square root of inverse TIMbp was applied and found to be affected by both SA and EMWD (r = 0.44 and r = 0.49, p < 0.001 for both). A regression model confirmed that together TIMmp and TIMbp can be used to estimate both SA and EMWD (R2 = 0.47 and R2 = 0.44, respectively, p < 0.001 for both). In TIMmp, EF peaks grow from basal to apical direction and EF decay is steeper in the proximity of the medial wall than in more lateral positions. Local potentials measured via TIMbp correlate with both SA and EMWD. Altogether, TIMmp and TIMbp can be used to assess the intracochlear and intrascalar position of the electrode array, and they may reduce the need for intra- and postoperative imaging in the future.
Collapse
Affiliation(s)
- Samuel Söderqvist
- Department of Otorhinolaryngology - Head and Neck Surgery and Tauno Palva Laboratory, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, Helsinki 00130, Finland.
| | - Ville Sivonen
- Department of Otorhinolaryngology - Head and Neck Surgery and Tauno Palva Laboratory, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, Helsinki 00130, Finland
| | - Juha Koivisto
- Department of Physics, University of Helsinki, Helsinki, Finland
| | - Antti Aarnisalo
- Department of Otorhinolaryngology - Head and Neck Surgery and Tauno Palva Laboratory, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, Helsinki 00130, Finland
| | - Saku T Sinkkonen
- Department of Otorhinolaryngology - Head and Neck Surgery and Tauno Palva Laboratory, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, Helsinki 00130, Finland
| |
Collapse
|
21
|
Rader T, Nachtigäller P, Linke T, Weißgerber T, Baumann U. Exponential fitting of spread of excitation response measurements in cochlear implants. J Neurosci Methods 2023; 391:109854. [PMID: 37031765 DOI: 10.1016/j.jneumeth.2023.109854] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 03/31/2023] [Accepted: 04/06/2023] [Indexed: 04/11/2023]
Abstract
BACKGROUND Hearing performance in cochlear implant (CI) users is variable. An objective measure which can allow a prediction of this performance is desirable. Spread of neural excitation (SoE) curves are an objective measure that can be obtained using the fitting software of cochlear implants and might be able to be used as a predictor. A novel method to interpret SoE curves is presented. New Method Spread of excitation measurements for three recording sites were fitted using two exponential functions. An asymmetric width measure was developed, defined as the distance in mm to the point, where 25% or 50% of peak normalized amplitude was reached, for each half of the SoE separately. Also, a novel population of subjects with MED-EL CIs is used. Furthermore, speech perception (speech reception threshold, SRT) was evaluated using a matrix sentence test in a multi-source noise field. RESULTS SoE width was narrowest for the basal recording site and widest for the apical recording site. Fitted SoE exponential functions were most asymmetric for the apical recording site. A significant positive correlation between sentence test SRT and SoE width at the apical recording site was found. Comparison with Existing Methods The use of an asymmetric width measure correlated strongly and positively with speech perception for apical recording sites, unlike the symmetric width measure used in previous studies. Presumably, longer electrodes allow stimulation of a more apical part of the cochlear. At the apical part of the cochlea, dendrites from a large region of the basilar membrane map to a narrow portion on the spiral ganglion, which might explain the observed asymmetry. CONCLUSIONS For subjects implanted with long electrode arrays, an asymmetric width measure correlates positively with apical SoE distance. However, due to lack of a sufficient amount of data, the results are currently less conclusive and need to be consolidated in a larger cohort of subjects.
Collapse
Affiliation(s)
- Tobias Rader
- Division of Audiology, Department for Otorhinolaryngology, University Hospital, Ludwig-Maximilians-Universität München, Munich, Germany
| | - Pascal Nachtigäller
- Division of Audiology, Department for Otorhinolaryngology, University Hospital, Ludwig-Maximilians-Universität München, Munich, Germany
| | - Theresa Linke
- Dermatology Bad Soden, Bad Soden, Germany; Division of Audiological Acoustics, Department for Otorhinolaryngology, University Hospital Frankfurt, Frankfurt, Germany
| | - Tobias Weißgerber
- Division of Audiological Acoustics, Department for Otorhinolaryngology, University Hospital Frankfurt, Frankfurt, Germany.
| | - Uwe Baumann
- Division of Audiological Acoustics, Department for Otorhinolaryngology, University Hospital Frankfurt, Frankfurt, Germany
| |
Collapse
|
22
|
Inoue T, Tona Y, Okano T, Omori K, Yamamoto N. Detection of Tip Fold-Over of the Slim Modiolar Electrode Using Intraoperative Mobile Cone-Beam Computed Tomography. Otolaryngol Head Neck Surg 2023. [PMID: 36939567 DOI: 10.1002/ohn.240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Revised: 11/17/2022] [Accepted: 12/10/2022] [Indexed: 01/26/2023]
Abstract
OBJECTIVE This study aimed to evaluate the importance of mobile cone-beam computed tomography in detecting tip fold-over of a slim modiolar electrode within the cochlea during surgery. STUDY DESIGN Retrospective case review. SETTING Tertiary medical center. METHODS From January 2020 to June 2022, 33 ears of 30 patients with normal cochlear morphology underwent cochlear implantation with slim modiolar electrodes and intraoperative mobile cone-beam computed tomography imaging. Furthermore, we retrospectively reviewed the medical records and images. RESULTS The tip fold-over of the electrodes was detected using mobile cone-beam computed tomography in 3 out of 33 ears (9.1%). We could not identify the tip fold-over by scouting plain X-ray images in 2 out of 3 cases before taking the cone-beam computed tomography images. Electrode removal and reinsertion were performed before wound closure and the successful reinsertion was confirmed by mobile cone-beam computed tomography. The folded electrode tips were located at 238.8°, 152°, and 185.8°. CONCLUSION Intraoperative mobile cone-beam computed tomography is useful in detecting the tip fold-over of the slim modiolar electrodes during surgery. Therefore, it was possible to reinsert the electrodes in all cases before closing the wound, eliminating the need for revision surgeries. Moreover, the analysis of mobile cone-beam computed tomography images may help to elucidate the mechanisms of electrode tip fold-over.
Collapse
Affiliation(s)
- Taishi Inoue
- Department of Otolaryngology, Japanese Red Cross Wakayama Medical Center, Wakayama, Japan
| | - Yosuke Tona
- Department of Otolaryngology-Head and Neck Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Takayuki Okano
- Department of Otolaryngology-Head and Neck Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Koichi Omori
- Department of Otolaryngology-Head and Neck Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Norio Yamamoto
- Department of Otolaryngology-Head and Neck Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan.,Department of Otolaryngology, Kobe City Medical Center General Hospital, Kobe, Hyogo, Japan
| |
Collapse
|
23
|
Söderqvist S, Sinkkonen ST, Sivonen V. The intraoperative relationship between intracochlear electrical field and excitability of the auditory nerve. Heliyon 2022; 8:e11970. [DOI: 10.1016/j.heliyon.2022.e11970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 10/10/2022] [Accepted: 11/22/2022] [Indexed: 12/03/2022] Open
|
24
|
Sharma RK, Smetak MR, Patro A, Lindquist NR, Perkins EL, Holder JT, Haynes DS, Tawfik KO. Speech Recognition Performance Differences Between Precurved and Straight Electrode Arrays From a Single Manufacturer. Otol Neurotol 2022; 43:1149-1154. [PMID: 36201525 DOI: 10.1097/mao.0000000000003703] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Precurved cochlear implant (CI) electrode arrays have demonstrated superior audiometric outcomes compared with straight electrodes in a handful of studies. However, previous comparisons have often failed to account for preoperative hearing and age. This study compares hearing outcomes for precurved and straight electrodes by a single manufacturer while controlling for these and other factors in a large cohort. STUDY DESIGN Retrospective cohort study. SETTING Tertiary academic medical center. PATIENTS Two hundred thirty-one adult CI recipients between 2015 and 2021 with cochlear (Sydney, Australia) 522/622 (straight) or 532/632 (precurved) electrode arrays. INTERVENTIONS Postactivation speech recognition and audiometric testing. MAIN OUTCOME MEASURES Speech recognition testing (consonant-nucleus-consonant word [CNCw] and AzBio) was collected at 6 and 12 months postactivation. Hearing preservation was characterized by a low-frequency pure-tone average shift, or the change between preoperative and postoperative low-frequency pure-tone average. RESULTS Two hundred thirty-one patients (253 ears) with 6-month and/or 12-month CNCw or AzBio testing were included. One hundred forty-nine (59%) and 104 (41%) ears were implanted with straight and precurved electrode arrays, respectively. Average age at implantation was 70 years (interquartile range [IQR], 58-77 y). There was no significant difference in mean age between groups. CNCw scores were significantly different ( p = 0.001) between straight (51%; IQR, 36-67%) and precurved arrays (64%; IQR, 48-72%). AzBio scores were not significantly different ( p = 0.081) between straight (72%; IQR, 51-87%) and precurved arrays (81%; IQR, 57-90%). Controlling for age, race, sex, preoperative hearing, and follow-up time, precurved electrode arrays performed significantly better on CNCw (b = 10.0; 95% confidence interval, 4.2-16.0; p < 0.001) and AzBio (b = 8.9; 95% confidence interval, 1.8-16.0;, p = 0.014) testing. Hearing preservation was not different between electrodes on adjusted models. CONCLUSION During the study period, patients undergoing placement of precurved electrode arrays had significantly higher CNC and AzBio scores than patients receiving straight electrodes, even after controlling for age, preoperative hearing, and follow-up time. PROFESSIONAL PRACTICE GAP AND EDUCATIONAL NEED Understanding the difference in audiometric outcomes between precurved and straight electrode arrays will help to guide electrode selection. LEARNING OBJECTIVE To understand differences in speech recognition scores postoperatively by electrode array type (precurved versus straight). DESIRED RESULT To demonstrate a difference in hearing performance postoperatively by electrode type. LEVEL OF EVIDENCE III. INDICATE IRB OR IACUC Approved by the Institutional IRB (090155).
Collapse
Affiliation(s)
- Rahul K Sharma
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| | - Miriam R Smetak
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| | - Ankita Patro
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| | - Nathan R Lindquist
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| | - Elizabeth L Perkins
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| | | | - David S Haynes
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| | - Kareem O Tawfik
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| |
Collapse
|
25
|
Claussen AD, Shibata SB, Kaufmann CR, Henslee A, Hansen MR. Comparative Analysis of Robotics-Assisted and Manual Insertions of Cochlear Implant Electrode Arrays. Otol Neurotol 2022; 43:1155-1161. [PMID: 36201552 PMCID: PMC10962863 DOI: 10.1097/mao.0000000000003707] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
HYPOTHESIS Robotics-assisted cochlear implant (CI) insertions will result in reduced intracochlear trauma when compared with manual, across multiple users. BACKGROUND Whether intracochlear trauma and translocations are two factors that may contribute to significant variability in CI outcomes remains to be seen. To address this issue, we have developed a robotics-assisted insertion system designed to aid the surgeon in inserting electrode arrays with consistent speeds and reduced variability. This study evaluated the effect of robotics-assisted insertions on the intracochlear trauma as compared with manual insertions in cadaveric cochleae in a simulated operative environment. METHODS Twelve neurotologists performed bilateral electrode insertions into cochleae of full cadaveric heads using both the robotics-assisted system and manual hand insertion. Lateral wall electrodes from three different manufacturers (n = 24) were used and randomized between surgeons. Insertion angle of the electrode and trauma scoring were evaluated using high-resolution three-dimensional x-ray microscopy and compared between robotics-assisted and manual insertions. RESULTS Three-dimensional x-ray microscopy provided excellent resolution to characterize the in situ trauma and insertion angle. Robotics-assisted insertions significantly decreased insertional intracochlear trauma as measured by reduced trauma scores compared with manual insertions (average: 1.3 versus 2.2, device versus manual, respectively; p < 0.05). There was no significant difference between insertion angles observed for manual and robotics-assisted techniques (311 ± 131° versus 307 ± 96°, device versus manual, respectively). CONCLUSIONS Robotics-assisted insertion systems enable standardized electrode insertions across individual surgeons and experience levels. Clinical trials are necessary to investigate whether insertion techniques that reduce insertional variability and the likelihood of intracochlear trauma also improve CI auditory outcomes.
Collapse
Affiliation(s)
| | - Seiji B Shibata
- Department of Otolaryngology-Head and Neck Surgery, University of Iowa
| | | | | | | |
Collapse
|
26
|
Leblans M, Zarowski A, Molisz A, van Dinther J, Dedeyne J, Lerut B, Kuhweide R, Offeciers E. Cochlear implant electrode array tip-foldover detection by electrode voltage telemetry. Cochlear Implants Int 2022:1-12. [DOI: 10.1080/14670100.2022.2148890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/05/2022]
Affiliation(s)
- Marc Leblans
- European Institute for ORL, GZA Sint-Augustinus, Antwerp, Belgium
| | - Andrzej Zarowski
- European Institute for ORL, GZA Sint-Augustinus, Antwerp, Belgium
| | - Andrzej Molisz
- Department of Family Medicine, Medical University of Gdansk, Gdańsk, Poland
| | | | - Janne Dedeyne
- ENT Department, AZ Sint-Jan Brugge-Oostende, Brugge, Belgium
| | - Bob Lerut
- ENT Department, AZ Sint-Jan Brugge-Oostende, Brugge, Belgium
| | - Rudolf Kuhweide
- ENT Department, AZ Sint-Jan Brugge-Oostende, Brugge, Belgium
| | - Erwin Offeciers
- European Institute for ORL, GZA Sint-Augustinus, Antwerp, Belgium
| |
Collapse
|
27
|
Munhall CC, Noble JH, Dawant B, Labadie RF. Cochlear Implant Translocation: Diagnosis, Prevention, and Clinical Implications. CURRENT OTORHINOLARYNGOLOGY REPORTS 2022. [DOI: 10.1007/s40136-022-00434-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
28
|
Matsumoto N, Akagi-Tsuchihashi N, Noda T, Komune N, Nakagawa T. Orientation of the Cochlea From a Surgeon's Perspective. OTOLOGY & NEUROTOLOGY OPEN 2022; 2:e017. [PMID: 38516627 PMCID: PMC10950153 DOI: 10.1097/ono.0000000000000017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Accepted: 06/23/2022] [Indexed: 03/23/2024]
Abstract
Background One of the mechanisms that cause tip fold-over is a misalignment between the electrode array's coiling direction and the cochlea's curving direction. Objectives We reviewed surgical videos and computed tomography (CT) datasets of the patients who underwent cochlear implantation procedures from January 2010 to December 2021, paying particular attention to the cochlea's orientation in the surgeon's microscopic view. Methods CT dataset and video recordings were analyzed to measure the "slope angle," which is the angle between the cochlea's coiling plane and the horizontal plane. Results There were 220 cases that met the criteria and completed the analysis. The mean slope angle was 12.1° ± 9.5°, with a minimum of -9.4° and maximum of 44.6°. However, each surgeon had a favored slope angle range. Conclusion Understanding the slope angle and making an effort to reduce the chance of misalignment during electrode insertion may help prevent tip fold-over of slim perimodiolar electrode arrays.
Collapse
Affiliation(s)
- Nozomu Matsumoto
- Department of Otorhinolaryngology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Nana Akagi-Tsuchihashi
- Department of Otorhinolaryngology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Teppei Noda
- Department of Otorhinolaryngology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Noritaka Komune
- Department of Otorhinolaryngology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Takashi Nakagawa
- Department of Otorhinolaryngology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| |
Collapse
|
29
|
Yu C, Debs S, Singh R, Kastetter S, Pierre-Louis A, Coelho DH. The case for intra-operative X-ray in cochlear implantation: Four illustrative cases and literature review. Cochlear Implants Int 2022; 23:332-338. [PMID: 36005270 DOI: 10.1080/14670100.2022.2112546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
Abstract
OBJECTIVES To demonstrate the utility of routine intraoperative plain film imaging in optimizing outcomes in cochlear implantation. INTRODUCTION Evolving surgical techniques, programming, and electrode arrays have all improved performance outcomes in cochlear implantation. Yet despite decreasing complication rates, electrode misplacement remains a common occurrence. Utilization of intraoperative confirmational tools (radiologic, electrophysiologic) remains unstandardized despite the acknowledged importance of proper electrode positioning. The purpose of this article is to illustrate the use and benefits of intraoperative X-ray (IOXR) in four cases, particularly in cases of normal electrophysiologic testing. METHODS Four cases performed by an experienced CI surgeon are discussed where electrode malposition was only detected through X-ray. Literature review was performed on the use of intraoperative imaging, focusing on plain film radiography. RESULTS Case 1-3 describe examples of resistance-free electrode insertion in patients with normal pre-operative imaging. Intraoperative impedances and neural response telemetry (NRT) were normal. However, IOXR ultimately revealed tip fold-over prompting array repositioning. Case 4 describes an elective replacement of a soft-failing device. Resistance was encountered during array insertion, with IOXR demonstrating incomplete insertion compared with prior imaging. Positioning was revised to achieve pre-revision insertion depth, demonstrating the utility of prior IOXR in revision cases. Literature review of IOXR is discussed. CONCLUSION Appropriate placement of the electrode is paramount to successful CI outcomes. These cases illustrate IOXR as a safe, effective method to ensure optimal placement even in cases of normal electrophysiologic testing, supporting its routine use even by the most seasoned surgeons.
Collapse
Affiliation(s)
- Cheryl Yu
- Department of Otolaryngology - Head & Neck Surgery, Virginia Commonwealth University Medical Center, Richmond, VA, USA
| | - Sarah Debs
- Department of Otolaryngology - Head & Neck Surgery, Virginia Commonwealth University Medical Center, Richmond, VA, USA
| | - Rhea Singh
- Department of Otolaryngology - Head & Neck Surgery, Virginia Commonwealth University Medical Center, Richmond, VA, USA
| | - Sean Kastetter
- Department of Otolaryngology - Head & Neck Surgery, Virginia Commonwealth University Medical Center, Richmond, VA, USA
| | - Akilah Pierre-Louis
- Department of Otolaryngology - Head & Neck Surgery, Virginia Commonwealth University Medical Center, Richmond, VA, USA
| | - Daniel H Coelho
- Department of Otolaryngology - Head & Neck Surgery, Virginia Commonwealth University Medical Center, Richmond, VA, USA
| |
Collapse
|
30
|
Waldeck S, Schmidt S, von Falck C, Chapot R, Brockmann M, Overhoff D. New hybrid multiplanar cone beam computed tomography-laser-fluoroscopic-guided approach in cochlear implant surgery. Int J Comput Assist Radiol Surg 2022; 17:1837-1843. [PMID: 35816271 PMCID: PMC9467958 DOI: 10.1007/s11548-022-02703-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2021] [Accepted: 06/10/2022] [Indexed: 11/05/2022]
Abstract
PURPOSE Cochlea implant surgery with proper positioning of the cochlear electrode can be challenging. Intraoperative real-time hybrid laser-fluoroscopic-guided navigation based on a multiplanar cone beam computed tomography (CBCT) dataset opens up the opportunity to immediate radiological control of primary electrode misalignments and offering new insights into the cochlea electrode insertion routes and favorable cochlear implant-insertion angle. METHODS In this retrospective study, 50 cases (29 males, 18 females) of conventional electrode implantation (without intraoperative image control; group A) and nine cases (7 males, 2 females) of CBCT-laser-fluoroscopic-guided surgery (group B) were included in the present study. CBCT-laser-guided surgery under real-time fluoroscopic control was conducted using an intraoperative C-arm CBCT. All patients received preoperative cross-sectional imaging (CT and MRI), in which cochlear malformation could be excluded. Postoperatively, we looked for electrode misplacements. RESULTS In group A, electrode misalignment was detected postoperatively in 14 of 50 cases (28.0%). In group B, primary electrode misalignment was detected intraoperatively in two patients (22.2%). In both patients, the misalignments were corrected in the same session. The comparison of cochlear insertion angles showed significant differences. Group A: 47.5 ± 2.6° (actual conventional surgery) vs 17.6 ± 2.8° (theoretical CBCT-laser-fluoroscopic-guided surgery) P < 0.001. Group A vs group B: 47.5 ± 2.6° (actual conventional surgery; Group A) vs 17.9 ± 2.5° (actual CBCT-laser-fluoroscopic-guided surgery; Group B) P < 0.001. CONCLUSION We consider that an intraoperative hybrid CBCT-laser-fluoroscopic-controlled approach in cochlear implant surgery using a C-arm CT can be beneficial, because electrode misalignments can be reduced and if it does occur, remedied in the same surgical session.
Collapse
Affiliation(s)
- Stephan Waldeck
- Department of Diagnostic and Interventional Radiology and Neuroradiology, Bundeswehr Central Hospital Koblenz, Rübenacher Straße 170, 56072, Koblenz, Germany. .,Institute of Neuroradiology, University Medical Centre Johannes Gutenberg University Mainz, Mainz, Langenbeckstraße 1, 55131, Germany.
| | - Sandra Schmidt
- Department of ENT Surgery, Bundeswehr Central Hospital Koblenz, Rübenacher Straße 170, 56072, Koblenz, Germany
| | - Christian von Falck
- Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Straße 1, 30625, Hanover, Germany
| | - René Chapot
- Department of Neuroradiology, Alfried Krupp Krankenhaus, Alfried-Krupp-Strasse 21, 45131, Essen, Germany
| | - Marc Brockmann
- Institute of Neuroradiology, University Medical Centre Johannes Gutenberg University Mainz, Mainz, Langenbeckstraße 1, 55131, Germany
| | - Daniel Overhoff
- Department of Diagnostic and Interventional Radiology and Neuroradiology, Bundeswehr Central Hospital Koblenz, Rübenacher Straße 170, 56072, Koblenz, Germany.,Department of Radiology and Nuclear Medicine, University Medical Centre Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| |
Collapse
|
31
|
Real-Time Data-Driven Approach for Prediction and Correction of Electrode Array Trajectory in Cochlear Implantation. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12136343] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Cochlear implants provide hearing perception to people with severe to profound hearing loss. The electrode array (EA) inserted during the surgery directly stimulates the hearing nerve, bypassing the acoustic hearing system. The complications during the EA insertion in the inner ear may cause trauma leading to infection, residual hearing loss, and poor speech perception. This work aims to reduce the trauma induced during electrode array insertion process by carefully designing a sensing method, an actuation system, and data-driven control strategy to guide electrode array in scala tympani. Due to limited intra-operative feedback during the insertion process, complex bipolar electrical impedance is used as a sensing element to guide EA in real time. An automated actuation system with three degrees of freedom was used along with a complex impedance meter to record impedance of consecutive electrodes. Prediction of EA direction (medial, middle, and lateral) was carried out by an ensemble of random forest, shallow neural network, and k-nearest neighbour in an offline setting with an accuracy of 86.86%. The trained ensemble was then utilized in vitro for prediction and correction of EA direction in real time in the straight path with an accuracy of 80%. Such a real-time system also has application in other electrode implants and needle and catheter insertion guidance.
Collapse
|
32
|
Misplaced Cochlear Implant Electrodes Outside the Cochlea: A Literature Review and Presentation of Radiological and Electrophysiological Findings. Otol Neurotol 2022; 43:567-579. [PMID: 35261380 DOI: 10.1097/mao.0000000000003523] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
HYPOTHESIS It is possible to detect when misplacement and malposition of the cochlear implant (CI) electrode array has occurred intraoperatively through different investigations. We aim to explore the literature surrounding cochlear implant misplacements and share our personal experience with such cases to formulate a quick-reference guide that may be able to help cochlear implant teams detect misplacements early. BACKGROUND Misplacement and malposition of a cochlear implant array can lead to poor hearing outcomes. Where misplacements go undetected during the primary surgery, patients may undergo further surgery to replace the implant array into the correct intracochlear position. METHODS Systematic literature review on cochlear implant misplacements and malpositions and a retrospective review of our program's cases in over 6,000 CI procedures. RESULTS Twenty-nine cases of CI misplacements are reported in the English literature. Sixteen cases of cochlear implant misplacements are reported from our institution with a rate of 0.28%. A further 12 cases of intracochlear malpositions are presented. The electrophysiological (CI electrically evoked auditory brainstem response, transimpedance matrix) and radiological (X-ray and computed tomography scan) findings from our experience are displayed in a tabulated quick-reference guide to show the possible characteristics of misplaced and malpositioned cochlear implant electrode arrays. CONCLUSION Both intraoperative electrophysiological and radiological tests can show when the array has been misplaced or if there is an intracochlear malposition, to prompt timely intra-operative reinsertion to yield better outcomes for patients.
Collapse
|
33
|
Leblans M, Sismono F, Vanpoucke F, van Dinther J, Lerut B, Kuhweide R, Offeciers E, Zarowski A. Novel Impedance Measures as Biomarker for Intracochlear Fibrosis. Hear Res 2022; 426:108563. [DOI: 10.1016/j.heares.2022.108563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 04/05/2022] [Accepted: 06/15/2022] [Indexed: 11/04/2022]
|
34
|
de Rijk SR, Hammond-Kenny A, Tam YC, Eitutis ST, Garcia C, Carlyon RP, Bance M. Detection of Extracochlear Electrodes Using Stimulation-Current- Induced Non-Stimulating Electrode Voltage Recordings With Different Electrode Designs. Otol Neurotol 2022; 43:e548-e557. [PMID: 35617005 DOI: 10.1097/mao.0000000000003512] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
HYPOTHESIS Stimulation-Current-Induced Non-Stimulating Electrode Voltage Recordings (SCINSEVs) can help detect extracochlear electrodes for a variety of Cochlear Implant (CI) devices. BACKGROUND Extracochlear electrodes (EEs) occur in 9 to 13% of cochlear implantations and commonly go unnoticed without imaging. Electrodes on the electrode array located extracochlearly are associated with non-auditory stimulation and a decrease in speech outcomes. We have previously shown that SCINSEVs, with hardware and software from one manufacturer, could detect EEs. Here, we test the generalizability to other manufacturers. METHODS Fresh-frozen human cadaveric heads were implanted with Cochlear Ltd. CI522 (CI-A) and MED-EL's FLEX24 (CI-B) electrodes. Contact impedances and SCIN- SEVs were measured, with Cochlear Ltd. research Custom Sound software (Transimpedance Matrix) and MED-EL's clinical MAESTRO (Impedance Field Telemetry), for full insertion and EEs in air, saline and soft tissue. An automated detection tool was optimized and tested for these implants. Intra-operative SCINSEVs with EEs were collected for clinical purposes for six patients. RESULTS The pattern of SCINSEVs changed in the transition zone from intracochlear to extracochlear electrodes, even with low contact impedances on EEs. Automated detection in the cadaveric specimens, with two or more EEs in saline or soft tissue, showed a mean 91% sensitivity and specificity for CI-A and 100% sensitivity and specificity for CI-B. Quantification of EEs showed significant correlations of r = 0.69 between estimated and actual EEs for CI-A and r = 0.76 for CI-B. CONCLUSION The applicability of SCINSEVs to detect extra- cochlear electrodes could be expanded to other cochlear implant companies despite differences in electrode array design and measurement software.
Collapse
Affiliation(s)
- Simone R de Rijk
- Department of Clinical Neurosciences, University of Cambridge
- Cambridge Hearing Group, University of Cambridge, Cambridge
| | | | - Yu C Tam
- Emmeline Centre, Cambridge University Hospitals NHS Foundation Trust
| | - Susan T Eitutis
- Cambridge Hearing Group, University of Cambridge, Cambridge
- Emmeline Centre, Cambridge University Hospitals NHS Foundation Trust
| | - Charlotte Garcia
- Cambridge Hearing Group, University of Cambridge, Cambridge
- MRC Cognition and Brain Sciences Unit, University of Cambridge, Cambridge, UK
| | - Robert P Carlyon
- Cambridge Hearing Group, University of Cambridge, Cambridge
- MRC Cognition and Brain Sciences Unit, University of Cambridge, Cambridge, UK
| | - Manohar Bance
- Department of Clinical Neurosciences, University of Cambridge
- Cambridge Hearing Group, University of Cambridge, Cambridge
| |
Collapse
|
35
|
Waldeck S, Helal R, Al-Dhamari I, Schmidt S, von Falck C, Chapot R, Brockmann M, Overhoff D. New ultra-fast algorithm for cochlear implant misalignment detection. Eur J Radiol 2022; 151:110283. [DOI: 10.1016/j.ejrad.2022.110283] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 03/07/2022] [Accepted: 03/30/2022] [Indexed: 02/08/2023]
|
36
|
Van de Heyning P, Roland P, Lassaletta L, Agrawal S, Atlas M, Baumgartner WD, Brown K, Caversaccio M, Dazert S, Gstoettner W, Hagen R, Hagr A, Jablonski GE, Kameswaran M, Kuzovkov V, Leinung M, Li Y, Loth A, Magele A, Mlynski R, Mueller J, Parnes L, Radeloff A, Raine C, Rajan G, Schmutzhard J, Skarzynski H, Skarzynski PH, Sprinzl G, Staecker H, Stöver T, Tavora-Viera D, Topsakal V, Usami SI, Van Rompaey V, Weiss NM, Wimmer W, Zernotti M, Gavilan J. Suitable Electrode Choice for Robotic-Assisted Cochlear Implant Surgery: A Systematic Literature Review of Manual Electrode Insertion Adverse Events. Front Surg 2022; 9:823219. [PMID: 35402479 PMCID: PMC8987358 DOI: 10.3389/fsurg.2022.823219] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Accepted: 02/09/2022] [Indexed: 12/05/2022] Open
Abstract
Background and Objective The cochlear implant (CI) electrode insertion process is a key step in CI surgery. One of the aims of advances in robotic-assisted CI surgery (RACIS) is to realize better cochlear structure preservation and to precisely control insertion. The aim of this literature review is to gain insight into electrode selection for RACIS by acquiring a thorough knowledge of electrode insertion and related complications from classic CI surgery involving a manual electrode insertion process. Methods A systematic electronic search of the literature was carried out using PubMed, Scopus, Cochrane, and Web of Science to find relevant literature on electrode tip fold over (ETFO), electrode scalar deviation (ESD), and electrode migration (EM) from both pre-shaped and straight electrode types. Results A total of 82 studies that include 8,603 ears implanted with a CI, i.e., pre-shaped (4,869) and straight electrodes (3,734), were evaluated. The rate of ETFO (25 studies, 2,335 ears), ESD (39 studies, 3,073 ears), and EM (18 studies, 3,195 ears) was determined. An incidence rate (±95% CI) of 5.38% (4.4-6.6%) of ETFO, 28.6% (26.6-30.6%) of ESD, and 0.53% (0.2-1.1%) of EM is associated with pre-shaped electrodes, whereas with straight electrodes it was 0.51% (0.1-1.3%), 11% (9.2-13.0%), and 3.2% (2.5-3.95%), respectively. The differences between the pre-shaped and straight electrode types are highly significant (p < 0.001). Laboratory experiments show evidence that robotic insertions of electrodes are less traumatic than manual insertions. The influence of round window (RW) vs. cochleostomy (Coch) was not assessed. Conclusion Considering the current electrode designs available and the reported incidence of insertion complications, the use of straight electrodes in RACIS and conventional CI surgery (and manual insertion) appears to be less traumatic to intracochlear structures compared with pre-shaped electrodes. However, EM of straight electrodes should be anticipated. RACIS has the potential to reduce these complications.
Collapse
Affiliation(s)
- Paul Van de Heyning
- Department of Otorhinolaryngology Head and Neck Surgery, Antwerp University Hospital, University of Antwerp, Antwerp, Belgium
- Department of Translational Neurosciences, University of Antwerp, Antwerp, Belgium
| | - Peter Roland
- Department of Otolaryngology, Head & Neck Surgery, University of Texas Southwestern Medical Center, Dallas, TX, United States
| | - Luis Lassaletta
- Hospital Universitario La Paz, Institute for Health Research (IdiPAZ), Madrid, Spain
| | - Sumit Agrawal
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, ON, Canada
| | - Marcus Atlas
- Ear Sciences Institute Australia, Lions Hearing Clinic, Perth, WA, Australia
| | | | - Kevin Brown
- UNC Ear and Hearing Center at Chapel Hill School of Medicine, Chapel Hill, NC, United States
| | - Marco Caversaccio
- Department for ENT, Head and Neck Surgery, Bern University Hospital, Bern, Switzerland
| | - Stefan Dazert
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth University Hospital Bochum, Bochum, Germany
| | | | - Rudolf Hagen
- Würzburg ENT University Hospital, Würzburg, Germany
| | - Abdulrahman Hagr
- King Abdullah Ear Specialist Center, King Saud University Medical City, King Saud University, Riyadh, Saudi Arabia
| | - Greg Eigner Jablonski
- Institute of Clinical Medicine, University of Oslo, Oslo, Norway
- Department of Otorhinolaryngology & Head and Neck Surgery, Oslo University Hospital, Rikshospitalet, Oslo, Norway
| | | | - Vladislav Kuzovkov
- St. Petersburg ENT and Speech Research Institute, St. Petersburg, Russia
| | - Martin Leinung
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Yongxin Li
- Department of Otorhinolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, China
- Key Laboratory of Otolaryngology Head and Neck Surgery (Capital Medical University), Ministry of Education, Beijing, China
| | - Andreas Loth
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Astrid Magele
- Ear, Nose and Throat Department, University Clinic St. Poelten, Karl Landsteiner Private University, St. Poelten, Austria
| | - Robert Mlynski
- Department of Otorhinolaryngology, Head and Neck Surgery, “Otto Körner” Rostock University Medical Center, Rostock, Germany
| | - Joachim Mueller
- Klinik und Poliklinik für Hals-, Nasen- und Ohrenheilkunde, Ludwig-Maximilians-Universitat Munchen, Munchen, Germany
| | - Lorne Parnes
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, ON, Canada
| | - Andreas Radeloff
- Division of Oto-Rhino-Laryngology, Evangelisches Krankenhaus Oldenburg, Research Center of Neurosensory Sciences, University Oldenburg, Oldenburg, Germany
| | - Chris Raine
- Bradford Royal Infirmary Yorkshire Auditory Implant Center, Bradford, United Kingdom
| | - Gunesh Rajan
- Department of Otolaryngology, Head and Neck Surgery, Luzerner Kantonsspital, Luzern, Medical Sciences Department of Health Sciences and Medicine. University of Lucerne, Luzern, Switzerland. Otolaryngology, Head & Neck Surgery, Medical School University of Western Australia, Perth, WA, Australia
| | - Joachim Schmutzhard
- Department of Otorhinolaryngology, Medical University of Innsbruck, Innsbruck, Austria
| | - Henryk Skarzynski
- Department of Teleaudiology and Screening, World Hearing Center of the Institute of Physiology and Pathology of Hearing, Kajetany, Poland
| | - Piotr H. Skarzynski
- Department of Teleaudiology and Screening, World Hearing Center of the Institute of Physiology and Pathology of Hearing, Kajetany, Poland
| | - Georg Sprinzl
- Ear, Nose and Throat Department, University Clinic St. Poelten, Karl Landsteiner Private University, St. Poelten, Austria
| | - Hinrich Staecker
- Kansas University Center for Hearing and Balance Disorders, Kansas City, KS, United States
| | - Timo Stöver
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Frankfurt, Frankfurt am Main, Germany
| | | | - Vedat Topsakal
- Department of ENT HNS, University Hospital Brussels, Brussels, Belgium
| | - Shin-Ichi Usami
- Department of Hearing Implant Sciences, Shinshu University School of Medicine, Nagano, Japan
| | - Vincent Van Rompaey
- Department of Otorhinolaryngology Head and Neck Surgery, Antwerp University Hospital, University of Antwerp, Antwerp, Belgium
- Department of Translational Neurosciences, University of Antwerp, Antwerp, Belgium
| | - Nora M. Weiss
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth University Hospital Bochum, Bochum, Germany
| | - Wilhelm Wimmer
- Department for ENT, Head and Neck Surgery, Bern University Hospital, Bern, Switzerland
| | - Mario Zernotti
- Catholic University of Córdoba and National University of Córdoba, Córdoba, Argentina
| | - Javier Gavilan
- Hospital Universitario La Paz, Institute for Health Research (IdiPAZ), Madrid, Spain
| |
Collapse
|
37
|
Burck I, Drath F, Albrecht MH, D Angelo T, Ackermann H, Scholtz JE, Yel I, Stöver T, Helbig S, Vogl TJ, Kaltenbach B, Scholtz JE. Visualization of Different Types of Cochlear Implants in Postoperative Cone-Beam CT Imaging. Acad Radiol 2022; 29 Suppl 3:S88-S97. [PMID: 33840600 DOI: 10.1016/j.acra.2021.02.025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2020] [Revised: 02/11/2021] [Accepted: 02/23/2021] [Indexed: 11/20/2022]
Abstract
RATIONALE AND OBJECTIVES To evaluate cone-beam computed-tomography (CBCT) images of the temporal bone for radiological delineation, metal artifacts, and accuracy for localization of six different electrode arrays after cochlear device implantation. MATERIALS AND METHODS This retrospective study included 116 patients who underwent CBCT (120kV, 7.1mA) within 24 hours after cochlear device implantation. Exclusion criteria were anatomical abnormalities, and electrode misinsertion. Six different CI electrodes were implanted: Advanced Bionics HiFocus Mid-Scala, Cochlear Contour Advance, Cochlear Slim-Straight, Cochlear Slim-Modiolar, MED-EL Flex 24 and MED-EL Flex 28. Two radiologists rated independently presence of metal artifacts, overall image quality, as well as dedicated visualization of the osseous spiral lamina, inner and outer cochlear wall, single electrode contacts, and electrode position using 5-point-Likert scales. Inter-rater agreement was calculated by using Cohen's kappa and intraclass correlation. RESULTS Of 116 patients, 94 (81.0%; 56.1 ± 16.9 years; age range, 13-86 years; 49 [52.1%] females) were included in the study. Overall image quality was rated good for all electrode models without significant differences (p = 0.061). Depiction of electrode contacts was rated significantly better for Advanced Bionics HiFocus Mid-Scala, Cochlear Slim-Straight, and MED-EL Flex 24 and 28 compared to Cochlear Contour Advance and Slim-Modiolar (p < 0.001). Depiction of the osseous spiral lamina (p = 0.20), inner (p = 0.42) and outer cochlear wall (p = 0.35), metal artifacts (p = 0.18), and electrode position (p = 0.31) did not show significant differences between electrode models. Inter-rater agreement varied from substantial to almost perfect (0.70-0.93). CONCLUSION CBCT provides excellent visualization of all evaluated CI electrode types, in particular electrode arrays with greater spacing between contacts and contact size allow improved radiologic evaluation.
Collapse
Affiliation(s)
- Iris Burck
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt 60590, Germany.
| | - Franziska Drath
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt 60590, Germany
| | - Moritz H Albrecht
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt 60590, Germany
| | - Tommaso D Angelo
- Department of Biomedical Sciences and Morphological and Functional Imaging, University Hospital Messsina, Messina, Italy
| | - Hanns Ackermann
- Institute of Biostatistics and Mathematical Modeling, University Hospital Frankfurt, Frankfurt, Germany
| | - Jan-Erik Scholtz
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt 60590, Germany
| | - Ibrahim Yel
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt 60590, Germany
| | - Timo Stöver
- Department of Otorhinolaryngology, University Hospital Frankfurt, Frankfurt, Germany
| | - Silke Helbig
- Department of Otorhinolaryngology, University Hospital Frankfurt, Frankfurt, Germany
| | - Thomas J Vogl
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt 60590, Germany
| | - Benjamin Kaltenbach
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt 60590, Germany
| | - Jan-Erik Scholtz
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt 60590, Germany
| |
Collapse
|
38
|
Sijgers L, Huber A, Tabibi S, Grosse J, Roosli C, Boyle P, Koka K, Dillier N, Pfiffner F, Dalbert A. Predicting Cochlear Implant Electrode Placement Using Monopolar, Three-Point and Four-Point Impedance Measurements. IEEE Trans Biomed Eng 2022; 69:2533-2544. [PMID: 35143392 DOI: 10.1109/tbme.2022.3150239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE This study aimed to investigate the relationship between cochlear implant (CI) electrode distances to the cochleas inner wall (the modiolus) and electrical impedance measurements made at the CIs electrode contacts. We introduced a protocol for three-point impedances in which we recorded bipolar impedances in response to monopolar stimulation at a neighboring electrode. We aimed to assess the usability of three-point impedances and two existing CI impedance measurement methods (monopolar and four-point impedances) for predicting electrode positioning during CI insertion. METHODS Impedances were recorded during stepwise CI electrode array insertions in cadaveric human temporal bones. The positioning of the electrodes with respect to the modiolus was assessed at each step using cone beam computed tomography. Linear mixed regression analysis was performed to assess the relationship between the impedances and electrode-modiolar distances. The experimental results were compared to clinical impedance data and to an existing lumped-element model of an implanted CI. RESULTS Three-point and four-point impedances strongly correlated with electrode-modiolar distance. In contrast, monopolar impedances were only minimally affected by changes in electrode positioning with respect to the modiolus. An overall model specificity of 62% was achieved when incorporating all impedance parameters. This specificity could be increased beyond 73% when prior expectations of electrode positioning were incorporated in the model. CONCLUSION Three-point and four-point impedances are promising measures to predict electrode-modiolar distance in real-time during CI insertion. SIGNIFICANCE This work shows how electrical impedance measurements can be used to predict the CIs electrode positioning in a biologically realistic model.
Collapse
|
39
|
Högerle C, Englhard A, Simon F, Grüninger I, Mlynski R, Hempel JM, Müller J. Cochlear Implant Electrode Tip Fold-Over: Our Experience With Long and Flexible Electrode. Otol Neurotol 2022; 43:64-71. [PMID: 34619728 DOI: 10.1097/mao.0000000000003362] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The aim of this study was to retrospectively investigate if there is any incidence of electrode tip fold-over with 31.5 mm long and flexible lateral wall electrodes implanted in two high-volume Cochlear Implant (CI) centers in Germany. In addition, a detailed literature review was performed to capture all the peer-reviewed publications reporting on tip fold-over with CI electrodes from different CI brands for comparison. METHODS Post-operative X-ray images of FLEX SOFT electrode from MED-EL in Stenver's view were retrospectively investigated for the presence of electrode tip fold-over from 378 consecutive cases in two high-volume CI centers in Germany. All patients were implanted between 2010 and 2018 by three individual experienced CI surgeons using round window and extended round window approach for CI electrode insertion. A literature review was performed following a thorough PubMed (https://www.ncbi.nlm.nih.gov/pubmed/) search using the keywords "cochlear implant electrode tip fold-over" or "cochlear implant electrode tip roll-over" to capture articles that were published until December 2020 in English language only. Articles selection was based on electrode-related issues investigated only in-patient cases applying imaging modality. Those studies investigated tip fold-over in cadaveric temporal bones and cases with inner-ear malformation excluded. RESULTS No single case of tip fold-over was clinically detected from the retrospective investigation of post-operative X-ray images from 378 consecutive cases. The electrode angular insertion depth as measured applying the cochlear coordinate system, varied from a minimum of 560° to a maximum of 720°. The literature review on the tip fold-over issue resulted in 24 peer-reviewed published articles in total. Tip fold-over with pre-curved modiolar-hugging electrodes was reported in 85 cases out of 1,606 implantations making an incidence rate of 5.3%. With the straight lateral wall electrodes, the tip fold-over was reported in four cases out of 398 implantations making an incidence rate of 1%, not including the number of implantations reported in the current study. Otherwise it would be 0.5%. CONCLUSION Electrode tip fold-over with 31.5 mm long flexible lateral wall electrodes is highly exceptional and this can be generalized to any of the straight lateral wall electrodes from any CI brand. The literature review on tip fold-over revealed an incidence rate of 5.3% with pre-curved or modiolar-hugging electrodes and 1% with straight lateral wall electrodes from CI brands. Including this series of 0% tip fold-over, the incidence rate of electrode tip fold-over with LW electrode type would be 0.5%.
Collapse
Affiliation(s)
- Catalina Högerle
- Department of Otorhinolaryngology, Head and Neck Surgery, Ludwig Maximilians University, Munich
| | - Anna Englhard
- Department of Otorhinolaryngology, Head and Neck Surgery, Ludwig Maximilians University, Munich
| | - Florian Simon
- Department of Otorhinolaryngology, Head and Neck Surgery, Ludwig Maximilians University, Munich
| | - Ivo Grüninger
- Department of Otorhinolaryngology, Head and Neck Surgery, Ludwig Maximilians University, Munich
| | - Robert Mlynski
- Department of Otorhinolaryngology, Head and Neck Surgery "Otto Körner," Rostock University Medical Center, Rostock, Germany
| | - John-Martin Hempel
- Department of Otorhinolaryngology, Head and Neck Surgery, Ludwig Maximilians University, Munich
| | - Joachim Müller
- Department of Otorhinolaryngology, Head and Neck Surgery, Ludwig Maximilians University, Munich
| |
Collapse
|
40
|
Horvath B, Perenyi A, Molnar FA, Nagy R, Csanady M, Kiss JG, Rovo L. A new method of preoperative assessment of correct electrode array alignment based on post-operative measurements in a cochlear implanted cohort. Eur Arch Otorhinolaryngol 2022; 279:5631-5638. [PMID: 35727414 PMCID: PMC9649508 DOI: 10.1007/s00405-022-07421-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Accepted: 04/25/2022] [Indexed: 01/04/2023]
Abstract
PURPOSE During cochlear implantation surgery, a range of complications may occur such as tip fold-over. We recently developed a method to estimate the insertion orientation of the electrode array. The aim of the study was to determine the optimal angle of orientation in a cohort of cochlear implanted patients. METHODS On eighty-five CT scans (80 uncomplicated insertions and 5 cases with tip fold-over), location of the electrode array's Insertion Guide (IG), Orientation marker (OM) and two easily identifiable landmarks (the round window (RW) and the incus short process (ISP)) were manually marked. The angle enclosed by ISP-RW line and the Cochlear™ Slim Modiolar electrode array's OM line determined the electrode array insertion angle. RESULTS The average insertion angle was 45.0-47.2° ± 10.4-12° SD and was validated with 98% confidence interval. Based on the measurements obtained, patients' sex and age had no impact on the size of this angle. Although the angles of the tip fold-over cases (44.9°, 46.9°, 34.2°, 54.3°, 55.9°) fell within this average range, the further it diverted from the average it increased the likelihood for tip fold-over. CONCLUSION Electrode array insertion in the individually calculated angle relative to the visible incus short process provides a useful guide for the surgeon when aiming for the optimal angle, and potentially enhances good surgical outcomes. Our results show that factors other than the orientation angle may additionally contribute to failures in implantation when the Slim Modiolar electrode is used.
Collapse
Affiliation(s)
- Bence Horvath
- Doctoral School of Clinical Medicine, University of Szeged, Szeged, Hungary.
- Department of Oto-Rhino- Laryngology and Head- Neck Surgery, University of Szeged, Szeged, Hungary.
| | - Adam Perenyi
- Department of Oto-Rhino- Laryngology and Head- Neck Surgery, University of Szeged, Szeged, Hungary
| | | | - Roland Nagy
- Department of Oto-Rhino- Laryngology and Head- Neck Surgery, University of Szeged, Szeged, Hungary
| | - Miklos Csanady
- Department of Oto-Rhino- Laryngology and Head- Neck Surgery, University of Szeged, Szeged, Hungary
| | - Jozsef Geza Kiss
- Department of Oto-Rhino- Laryngology and Head- Neck Surgery, University of Szeged, Szeged, Hungary
| | - Laszlo Rovo
- Department of Oto-Rhino- Laryngology and Head- Neck Surgery, University of Szeged, Szeged, Hungary
| |
Collapse
|
41
|
Fan Y, Zhang D, Banalagay R, Wang J, Noble JH, Dawant BM. Hybrid active shape and deep learning method for the accurate and robust segmentation of the intracochlear anatomy in clinical head CT and CBCT images. J Med Imaging (Bellingham) 2021; 8:064002. [PMID: 34853805 DOI: 10.1117/1.jmi.8.6.064002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2020] [Accepted: 11/08/2021] [Indexed: 11/14/2022] Open
Abstract
Purpose: Robust and accurate segmentation methods for the intracochlear anatomy (ICA) are a critical step in the image-guided cochlear implant programming process. We have proposed an active shape model (ASM)-based method and a deep learning (DL)-based method for this task, and we have observed that the DL method tends to be more accurate than the ASM method while the ASM method tends to be more robust. Approach: We propose a DL-based U-Net-like architecture that incorporates ASM segmentation into the network. A quantitative analysis is performed on a dataset that consists of 11 cochlea specimens for which a segmentation ground truth is available. To qualitatively evaluate the robustness of the method, an experienced expert is asked to visually inspect and grade the segmentation results on a clinical dataset made of 138 image volumes acquired with conventional CT scanners and of 39 image volumes acquired with cone beam CT (CBCT) scanners. Finally, we compare training the network (1) first with the ASM results, and then fine-tuning it with the ground truth segmentation and (2) directly with the specimens with ground truth segmentation. Results: Quantitative and qualitative results show that the proposed method increases substantially the robustness of the DL method while having only a minor detrimental effect (though not significant) on its accuracy. Expert evaluation of the clinical dataset shows that by incorporating the ASM segmentation into the DL network, the proportion of good segmentation cases increases from 60/177 to 119/177 when training only with the specimens and increases from 129/177 to 151/177 when pretraining with the ASM results. Conclusions: A hybrid ASM and DL-based segmentation method is proposed to segment the ICA in CT and CBCT images. Our results show that combining DL and ASM methods leads to a solution that is both robust and accurate.
Collapse
Affiliation(s)
- Yubo Fan
- Vanderbilt University, Department of Computer Science, Nashville, Tennessee, United States
| | | | - Rueben Banalagay
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
| | - Jianing Wang
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
| | - Jack H Noble
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
| | - Benoit M Dawant
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
| |
Collapse
|
42
|
Transimpedance Matrix Measurements Reliably Detect Electrode Tip Fold-over in Cochlear Implantation. Otol Neurotol 2021; 42:e1494-e1502. [PMID: 34766947 DOI: 10.1097/mao.0000000000003334] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE During cochlear implantation, electrophysiological tests are performed to document safe technical functioning of implant and electrodes. In rare cases, the apical part of the electrode folds over during insertion. The data from transimpedance matrix (TIM) measurements enable the generation of a heat map or TIM profile measuring the spatial distribution of voltage. The aim of this study was to determine the accuracy of heat-map TIM profiles and compare them with spread of excitation (SOE) measurements and intraoperative imaging for prediction of electrode malposition. STUDY DESIGN Non-randomized study. SETTING Tertiary referral center. PATIENTS AND INTERVENTIONS One hundred patients who underwent cochlear implantation with completed TIM measurements, SOE data and perioperative imaging met the inclusion criteria and were enrolled. MAIN OUTCOME MEASURE The electrophysiological data on the electrode array positioning was compared with temporal bone imaging. RESULTS In seven cases, TIM measurements showed irregular results. In two cases, irregular TIM profiles were registered, but SOE data and 3D x-ray of the temporal bone didn't display deviated electrode positioning. A 3D x-ray of the skull displayed electrode tip fold-over in four cases and electrode buckling in one case. Sensitivity of TIM measurements and SOE data was 100%, specificity of TIM measurements was 97.89%, and specificity of SOE data was 98.93%. CONCLUSION Out of 100 patients using TIM measurements for detection of electrode malpositioning, no false negative cases were detected. TIM measurements successfully detect electrode malposition in an intraoperative setting. Different heat map patterns may be observed depending on location and type of malposition.
Collapse
|
43
|
Hou L, Du X, Boulgouris NV, Hafeez N, Coulson C, Irving R, Begg P, Brett P. A Capacitive Cochlear Implant Electrode Array Sensing System to Discriminate Fold-Over Pattern. JOURNAL OF SPEECH, LANGUAGE, AND HEARING RESEARCH : JSLHR 2021; 64:3685-3696. [PMID: 34407380 DOI: 10.1044/2021_jslhr-21-00067] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Purpose During insertion of the cochlear implant electrode array, the tip of the array may fold back on itself and can cause serious complications to patients. This article presents a sensing system for cochlear implantation in a cochlear model. The electrode array fold-over behaviors can be detected by analyzing capacitive information from the array tip. Method Depending on the angle of the array tip against the cochlear inner wall when it enters the cochlear model, different insertion patterns of the electrode array could occur, including smooth insertion, buckling, and fold-over. The insertion force simulating the haptic feedback for surgeons and bipolar capacitance signals during the insertion progress were collected and compared. The Pearson correlation coefficient (PCC) was applied to the collected capacitive signals to discriminate the fold-over pattern. Results Forty-six electrode array insertions were conducted and the deviation of the measured insertion force varies between a range of 20% and 30%. The capacitance values from electrode pair (1, 2) were recorded for analyzing. A threshold for the PCC is set to be 0.94 that can successfully discriminate the fold over insertions from the other two types of insertions, with a success rate of 97.83%. Conclusions Capacitive measurement is an effective method for the detection of faulty insertions and the maximization of the outcome of cochlear implantation. The proposed capacitive sensing system can be used in other tissue implants in vessels, spinal cord, or heart.
Collapse
Affiliation(s)
- Lei Hou
- Brunel University London, United Kingdom
| | - Xinli Du
- Brunel University London, United Kingdom
| | | | | | - Chris Coulson
- Queen Elizabeth Hospital Birmingham, University Hospitals Birmingham, United Kingdom
| | - Richard Irving
- Queen Elizabeth Hospital Birmingham, University Hospitals Birmingham, United Kingdom
| | - Philip Begg
- Queen Elizabeth Hospital Birmingham, University Hospitals Birmingham, United Kingdom
| | - Peter Brett
- University of Southern Queensland, Toowoomba, Australia
| |
Collapse
|
44
|
Detection of Extracochlear Electrodes in Cochlear Implants with Electric Field Imaging/Transimpedance Measurements: A Human Cadaver Study. Ear Hear 2021; 41:1196-1207. [PMID: 31923041 PMCID: PMC7115972 DOI: 10.1097/aud.0000000000000837] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Objectives: Extracochlear electrodes in cochlear implants (CI), defined as individual electrodes on the electrode array located outside of the cochlea, are not a rare phenomenon. The presence of extracochlear electrodes frequently goes unnoticed and could result in them being assigned stimulation frequencies that are either not delivered to, or stimulating neurons that overlap with intracochlear electrodes, potentially reducing performance. The current gold-standard for detection of extracochlear electrodes is computed tomography (CT), which is time-intensive, costly and involves radiation. It is hypothesized that a collection of Stimulation-Current-Induced Non-Stimulating Electrode Voltage recordings (SCINSEVs), commonly referred to as “transimpedance measurements (TIMs)” or electric field imaging (EFI), could be utilized to detect extracochlear electrodes even when contact impedances are low. An automated analysis tool is introduced for detection and quantification of extracochlear electrodes. Design: Eight fresh-frozen human cadaveric heads were implanted with the Advanced Bionics HiRes90K with a HiFocus 1J lateral-wall electrode. The cochlea was flushed with 1.0% saline through the lateral semicircular canal. Contact impedances and SCINSEVs were recorded for complete insertion and for 1 to 5 extracochlear electrodes. Measured conditions included: air in the middle ear (to simulate electrodes situated in the middle ear), 1.0% saline in the middle ear (to simulate intraoperative conditions with saline or blood in the middle ear), and soft tissue (temporal muscle) wrapped around the extracochlear electrodes (to simulate postoperative soft-tissue encapsulation of the electrodes). Intraoperative SCINSEVs from patients were collected, for clinical purposes during slow insertion of the electrode array, as well as from a patient postoperatively with known extracochlear electrodes. Results: Full insertion of the cochlear implant in the fresh-frozen human cadaveric heads with a flushed cochlea resulted in contact impedances in the range of 6.06 ± 2.99 kΩ (mean ± 2SD). Contact impedances were high when the extracochlear electrodes were located in air, but remained similar to intracochlear contact impedances when in saline or soft tissue. SCINSEVs showed a change in shape for the extracochlear electrodes in air, saline, and soft tissue. The automated analysis tool showed a specificity and sensitivity of 100% for detection of two or more extracochlear electrodes in saline and soft tissue. The quantification of two or more extracochlear electrodes was correct for 84% and 81% of the saline and soft tissue measurements, respectively. Conclusions: Our analysis of SCINSEVs (specifically the EFIs from this manufacturer) shows good potential as a detection tool for extracochlear electrodes, even when contact impedances remain similar to intracochlear values. SCINSEVs could potentially replace CT in the initial screening for extracochlear electrodes. Detecting migration of the electrode array during the final stages of surgery could potentially prevent re-insertion surgery for some CI users. The automated detection tool could assist in detection and quantification of two or more extracochlear electrodes.
Collapse
|
45
|
Reduced Spread of Electric Field After Surgical Removal of Intracochlear Schwannoma and Cochlear Implantation. Otol Neurotol 2021; 41:e1297-e1303. [PMID: 33492805 DOI: 10.1097/mao.0000000000002884] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
OBJECTIVE The primary aim of the study was to explore whether reduced spread of electrical field is observed after partial or subtotal cochleoectomy and cochlear implantation compared with standard cochlear implantation. Secondarily, the influence on speech perception was explored comparing both groups. STUDY DESIGN Nonconcurrent cohort study. SETTING Monocentric study at a tertiary referral center. PATIENTS Twenty adult cochlear implant (CI) users after tumor resection with cochleoectomy of varying extent and 20 electrode-matched CI users with standard electrode insertion. INTERVENTIONS Partial and subtotal cochleoectomy for tumor removal and CI. OUTCOME MEASURES Trans-impedance, electrically evoked compound action potentials, and word recognition were measured. Relative impedance was computed as a function of distance between the stimulation and recording electrode. RESULTS Trans-impedance was smaller and more homogeneous in patients with partial or subtotal cochleoectomy than in the control group. In the tumor group, the mean relative impedance decreased to 0.20 (standard deviation [SD] = 0.03) at a distance of 1 electrode and to 0.25 (SD = 0.04) in the control group. After excluding seven patients with a second tumor in the internal auditory canal or cerebellopontine angle, with transmodiolar tumors, after near total cochleoectomy, or only extended cochleostomy, word recognition was 61% (SD = 19%) at 3 months and 75% (SD = 19%) at 12 months after activation of the audio processor in the tumor group. At 12 months, it was significantly (p < 0.05) better than in the control group (3 mo: 45%, SD = 25%; 12 mo: 53%, SD = 26%). A smaller trans-impedance is associated with a better word recognition. CONCLUSION We conclude that the surgical technique used for CI surgery after subtotal cochleoectomy reduces the spread of the electric field and overcomes the potential drawbacks in structure preservation associated with that technique.
Collapse
|
46
|
Söderqvist S, Lamminmäki S, Aarnisalo A, Hirvonen T, Sinkkonen ST, Sivonen V. Intraoperative transimpedance and spread of excitation profile correlations with a lateral-wall cochlear implant electrode array. Hear Res 2021; 405:108235. [PMID: 33901994 DOI: 10.1016/j.heares.2021.108235] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Revised: 03/21/2021] [Accepted: 03/25/2021] [Indexed: 01/18/2023]
Abstract
A limiting factor of cochlear implant technology is the spread of electrode-generated intracochlear electrical field (EF) leading to spread of neural excitation (SOE). In this study, we investigated the relation of the spread of the intracochlear EF, assessed via transimpedance matrix (TIM), and SOE. A total of 43 consecutive patients (ages 0.7-82 years; 31.0 ± 25.7 years, mean ± SD) implanted with a Cochlear Nucleus CI522 or CI622 cochlear implant with Slim Straight electrode array (altogether 51 ears) were included in the study. Cochlear nerve was visualized for all patients in preoperative imaging and there were no cochlear anomalies in the study sample. The stimulated electrodes were in the basal, middle, and apical parts of the electrode array (electrode numbers 6, 11, and 19, respectively). The stimulation level was 210 CL on average for the TIM measurement and always 230 CL for the SOE measurement. Approximately 90% of the individual TIM and SOE profiles correlated with each other (p < .05; r = 0.61-0.99). Also, the widths of the TIM and SOE peaks, computed at 50% of the maximum height, exhibited a weak correlation (r = 0.39, p = .007). The 50% widths of TIM and SOE were the same only in the apical part of the electrode array; in the basal part SOE was wider than TIM, and in the middle part TIM was wider than SOE (p < .01 and p = .048, respectively). Within each measurement, TIM 50% widths were different between all three parts of the electrode array, while for SOE, only the basal electrode differed from the middle electrode. Finally, the size of the cochlea and the 50% widths of TIM and SOE had the strongest correlation in the middle part of the electrode array (r = -0.63, and -0.37, respectively). Our results suggest that there is a correlation between the spread of intracochlear EF and neural SOE at least in the apical part of the electrode array used in this study, and that larger cochleae are associated with more focused TIM and SOE.
Collapse
Affiliation(s)
- Samuel Söderqvist
- Department of Otorhinolaryngology - Head and Neck Surgery, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, 00130 Helsinki, Finland.
| | - Satu Lamminmäki
- Department of Otorhinolaryngology - Head and Neck Surgery, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, 00130 Helsinki, Finland
| | - Antti Aarnisalo
- Department of Otorhinolaryngology - Head and Neck Surgery, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, 00130 Helsinki, Finland
| | - Timo Hirvonen
- Department of Otorhinolaryngology - Head and Neck Surgery, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, 00130 Helsinki, Finland
| | - Saku T Sinkkonen
- Department of Otorhinolaryngology - Head and Neck Surgery, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, 00130 Helsinki, Finland
| | - Ville Sivonen
- Department of Otorhinolaryngology - Head and Neck Surgery, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, 00130 Helsinki, Finland
| |
Collapse
|
47
|
Abstract
OBJECTIVE The intracochlear position of an electrode array may influence the outcome after cochlear implantation. The design of the electrode array can increase the risk of trauma causing penetration of the basilar membrane or shift of the electrode array into the scala vestibuli. The aim of the present study was to identify a scalar shift after implantation of two different electrode arrays developed by one manufacturer. STUDY DESIGN Retrospective analysis. SETTING Tertiary referral center. PATIENTS AND INTERVENTION Cochlear implant recipients implanted between 2010 and 2014 and receiving either a mid-scala (n = 30) or a perimodiolar (n = 30) electrode array. MAIN OUTCOME MEASURE Occurrence of scalar shift in association with the electrode type. RESULTS Scalar shift occurred in 26.7% (8 of 30) of the patients implanted with a perimodiolar electrode array and in 6.7% (2 of 30) of the patients implanted with the mid-scala electrode array. The mean insertion depth in the patients experiencing scalar shift after implantation of the mid-scala electrode was much deeper (21.59 ± 0.34 mm) when compared with the mean insertion depth of the patients with scalar shift after implantation with a perimodiolar electrode array (17.85 ± 2.19 mm). There tends to be a correlation between the cochlear length and the occurrence of a scalar shift. However, the number of patients with scalar shift in the mid-scala group is rather small. CONCLUSION Based on the presented data, more patients implanted with a perimodiolar electrode array have a scalar shift when compared with the midscalar electrode array.
Collapse
|
48
|
Ludwig S, Riemann N, Hans S, Christov F, Ludwig JM, Saxe J, Arweiler-Harbeck D. Evaluation of hearing preservation in adults with a slim perimodiolar electrode. Eur Arch Otorhinolaryngol 2021; 279:1233-1242. [PMID: 33830367 PMCID: PMC8897335 DOI: 10.1007/s00405-021-06755-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Accepted: 03/12/2021] [Indexed: 12/01/2022]
Abstract
PURPOSE Numerous endeavors have been undertaken to preserve hearing in cochlear implant (CI) patients. Particularly, optimization of electrode array design aims at preservation of residual hearing (RH). This study examines whether a slim perimodiolar (PM) electrode array could bear the capability to preserve hearing. METHODS A total of 47 patients underwent cochlear implantation receiving the PM electrode. (i) Patients with pure tone audiogram (PTA) thresholds better than 85 dB and/or hearing loss for Freiburg speech test numbers less than 60 dB and more than 50% maximum monosyllabic understanding were assigned to the RH group (n = 17), while all others belonged to the noRH group (n = 30). (ii) Another group implanted with a slim straight, lateral wall (LW) electrode was recruited for comparison. RESULTS We compared 17 RH-30 noRH patients all receiving the PM electrode. RH in PM recipients decreased faster than in LW recipients. No significant differences were observed between both (RH v/s noRH) groups in NRT thresholds, Freiburg speech test and A§E® phonemes. Analogous satisfaction levels were indicated through the questionnaires in terms of sound quality, hearing in silence, noise and directional hearing in both groups. CONCLUSIONS The results suggest that hearing preservation is influenced not only by electrode shape but various factors. This study opens an avenue for further investigations to elucidate and enumerate the causes for progressive hearing loss.
Collapse
Affiliation(s)
- Sonja Ludwig
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty Mannheim, University Hospital Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, Mannheim, Germany.
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University of Duisburg-Essen, Essen, Germany.
| | - Niklas Riemann
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Stefan Hans
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Florian Christov
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
- ENT Practice Cologne-Bonn, Wesseling, Germany
| | - Johannes Maximilian Ludwig
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Judith Saxe
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Diana Arweiler-Harbeck
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| |
Collapse
|
49
|
Trecca EMC, Adunka OF, Mattingly JK, Hiss MM, Cassano M, Malhotra PS, Riggs WJ. Electrocochleography Observations in a Series of Cochlear Implant Electrode Tip Fold-Overs. Otol Neurotol 2021; 42:e433-e437. [PMID: 33196531 DOI: 10.1097/mao.0000000000003008] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE Tip fold-over is a rare but serious complication of cochlear implant (CI) surgery. The purpose of this study was to present intraoperative electrocochleography (ECochG) observations in a series of CI electrode tip fold-overs. PATIENTS Five pediatric subjects undergoing CI surgery through a round window (RW) approach with a perimodiolar electrode array, who were diagnosed with either auditory neuropathy spectrum disorder or enlarged vestibular aqueduct. INTERVENTIONS Intraoperative RW ECochG during CI surgery: tone burst stimuli were presented from 95 to 110 dB SPL. MAIN OUTCOME MEASURES Magnitude and phase characteristics of ECochG responses obtained intraoperatively before and immediately after electrode insertion were examined for patients with and without tip fold-over. RESULTS Three subjects presented with tip fold-over and two formed the control group. Among fold-over cases, one participant exhibited an inversion in the starting phase of the cochlear microphonic response and a decrease in spectral magnitude from pre- to postinsertion. Both subjects who did not exhibit a change in phase had an increase in the ECochG-total response (ECochG-TR) magnitude. No case in the control group exhibited a change in starting phase. In regard to the ECochG-TR, all controls showed a decrease in the magnitude. CONCLUSIONS Despite the small number of patients, heterogeneous ECochG response patterns were observed within the fold-over group. Though these results are not conclusive, they can serve as a framework to begin to understand ECochG's utility in detecting intraoperative tip fold-over.
Collapse
Affiliation(s)
- Eleonora M C Trecca
- Department of Otolaryngology - Head and Neck Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.,Department of Otolaryngology - Head and Neck Surgery, University Hospital of Foggia, Foggia, Italy
| | - Oliver F Adunka
- Department of Otolaryngology - Head and Neck Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
| | - Jameson K Mattingly
- Department of Otolaryngology - Head and Neck Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
| | - Meghan M Hiss
- Department of Otolaryngology - Head and Neck Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
| | - Michele Cassano
- Department of Otolaryngology - Head and Neck Surgery, University Hospital of Foggia, Foggia, Italy
| | - Prashant S Malhotra
- Department of Otolaryngology - Head and Neck Surgery, Nationwide Children's Hospital, Columbus, Ohio, USA
| | - William J Riggs
- Department of Otolaryngology - Head and Neck Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
| |
Collapse
|
50
|
Transimpedance Matrix (TIM) Measurement for the Detection of Intraoperative Electrode Tip Foldover Using the Slim Modiolar Electrode: A Proof of Concept Study. Otol Neurotol 2021; 42:e124-e129. [PMID: 32941298 DOI: 10.1097/mao.0000000000002875] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The aim of this study is to report on our preliminary experience with Transimpedance Matrix (TIM)-measurement for the detection of cochlear implant electrode tip foldovers compared with intraoperative imaging in patients implanted with the slim modiolar electrode (SME). STUDY DESIGN Proof of concept study. SETTING Tertiary university referral center. PATIENTS Twenty five ears (in 22 patients) implanted consecutively with the SME. INTERVENTIONS Following cochlear implantation, intraoperative TIM-measurement and fluoroscopy were performed. One week postoperatively, the electrode position was evaluated using Computed Tomography (CT)-imaging. MAIN OUTCOME MEASURES Electrode array tip foldover. RESULTS Electrode array tip foldover occurred in three of the 25 cochlear implantations performed (12%). In each case, the foldover was detected by both TIM and fluoroscopy, leading to reposition and correct intracochlear placement of the array. CONCLUSIONS TIM-measurement is a promising method for the intraoperative detection of an electrode array tip foldover. The TIM-tool with intuitive heatmap display is easy to use, fast, and readily available to clinics using TIM-software in the operating theatre.
Collapse
|