1
|
Ochiai Y, Odagiri H, Hayasaka J, Okamura T, Suzuki Y, Mitsunaga Y, Fuchinoue K, Tanaka M, Nomura K, Yamashita S, Matsui A, Kikuchi D, Hoteya S. Feasibility of Rescue Colonoscopy Using a Short-type Enteroscope (SIF-H290S) without Overtube after Incomplete Colonoscopy: A Single-center Retrospective Pilot Study. J Anus Rectum Colon 2022; 6:282-288. [PMID: 36348946 PMCID: PMC9613409 DOI: 10.23922/jarc.2022-005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 05/06/2022] [Indexed: 11/05/2022] Open
Abstract
Objectives: Recently, a newly designed short-type single-balloon enteroscope (SBE), SIF-H290S, has been developed with a smaller outer diameter and a longer working length than conventional colonoscopes. It has passive bending and high-force transmission, making insertion easier. However, it is difficult to perform rescue colonoscopy with an SBE after incomplete colonoscopy in the same session. Therefore, this study evaluated the feasibility of consecutive rescue colonoscopy using SIF-H290S without overtube after incomplete colonoscopy. Methods: This was a single-center retrospective study. We included 19 rescue colonoscopies (19 patients) with SIF-H290S without overtube performed by 11 endoscopists in the SIF group and 38 rescue colonoscopies (38 patients) using a small-caliber colonoscope (PCF-PQ260L) were randomly selected for the control group from procedures performed by the same 11 endoscopists. We compared the cecal intubation rate and other outcomes, such as insertion time, between the two groups. Results: The median age of the patients was 72 and 69 years, with 8 and 26 males in the SIF and control groups, respectively. The median body mass index was 21.6 and 22.7 kg/m2 in the SIF and control groups, respectively. There were no significant differences in the patient backgrounds between the groups, except for the reason for incomplete colonoscopy (p = 0.048). The cecal intubation rate was 78.9% (15/19 procedures) and 92.1% (35/38 procedures) in the SIF and control groups, respectively. Conclusions: This study revealed the real-world experience and feasibility of rescue colonoscopy using SIF-H290S, which could be a potential rescue device option after incomplete colonoscopy.
Collapse
Affiliation(s)
| | | | | | | | - Yugo Suzuki
- Department of Gastroenterology, Toranomon Hospital
| | | | | | | | | | | | - Akira Matsui
- Department of Gastroenterology, Toranomon Hospital
| | | | - Shu Hoteya
- Department of Gastroenterology, Toranomon Hospital
| |
Collapse
|
2
|
Al-Toma A, Oude Hergelink DM, Tenthof van Noorden J, Koornstra JJ. Prospective evaluation of the motorized spiral enteroscope for previous incomplete colonoscopy. Endosc Int Open 2022; 10:E1112-E1117. [PMID: 36238532 PMCID: PMC9552671 DOI: 10.1055/a-1869-2541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 05/30/2022] [Indexed: 11/23/2022] Open
Abstract
Background and study aims A significant percentage of colonoscopies remain incomplete because of failure to intubate the cecum. The motorized spiral enteroscope (MSE) technique, originally developed for deep small bowel enteroscopy, may be an effective alternative technique in cases of incomplete examination of abnormally long colons (dolichocolon). We prospectively evaluated the success rate of cecal intubation, safety and the therapeutic consequences of using MSE after incomplete conventional colonoscopy. Patients and methods A total of 36 consecutive patients with an indication for diagnostic and/or therapeutic colonoscopy were prospectively enrolled in this multicenter trial. All patients had undergone at least one incomplete colonoscopy attributed to abnormally long colons. Patients with incomplete colonoscopy due to stenosis were excluded. Results Twenty-two men and 14 women (median age 66 years, range 35-82) were enrolled. Median procedure time was 30 minutes (range 16-50). Cecal intubation rate was 100 % and median cecal intubation time was 10 minutes (range 4-30). Abnormalities, mostly neoplastic lesions, were detected in 23 of 36 patients, corresponding to a diagnostic yield of 64 %. All these findings were in the right side of the colon and had not been described by the antecedent incomplete coloscopy. No adverse events occurred. Conclusions In case of a difficult and long colon, MSE is safe and effective for diagnostic and therapeutic colonoscopy. It may provide an attractive solution to accomplish completeness of previous incomplete colonoscopies in these patients.
Collapse
Affiliation(s)
- Abdulbaqi Al-Toma
- Department of Gastroenterology and hepatology, St. Antonius hospital, Nieuwegein, the Netherlands
| | - Dorien M. Oude Hergelink
- Department of Gastroenterology & Hepatology, University Medical Centre Groningen, University of Groningen, The Netherlands
| | | | - Jan Jacob Koornstra
- Department of Gastroenterology & Hepatology, University Medical Centre Groningen, University of Groningen, The Netherlands
| |
Collapse
|
3
|
Alexander R R, Anastasios K, Diana E Y, Christopher F, Artur N, Kenneth T, Ervin T, John N P, Gabriele WJ. Balloon-Assisted Colonoscopy after Incomplete Conventional Colonoscopy-Experience from Two European Centres with A Comprehensive Review of the Literature. J Clin Med 2020; 9:2981. [PMID: 32942749 PMCID: PMC7564861 DOI: 10.3390/jcm9092981] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Revised: 09/03/2020] [Accepted: 09/11/2020] [Indexed: 12/22/2022] Open
Abstract
Conventional colonoscopy (CC) allows access for colonic investigation and intervention; in the small group in whom CC is unsuccessful alternative imaging is often sufficient. There remains a subset, however, requiring full colonic visualisation or intervention. Balloon-assisted colonoscopy (BAC) gives a further option when access is difficult. Aims: This study aims to present the experience with BAC of two European tertiary referral centres. Methods: Procedures were carried out under local protocol over 15-years (2006-2020). Markers of procedural quality such as caecal intubation, complications and comfort were retrospectively compiled and analysed. Published evidence was summarised for comparison. Results: 122 procedures were undertaken, with polyps the most frequent indication and 90.2% having at least one previously incomplete CC. Features associated with difficult colonoscopy were common, including intraabdominal surgery (32.0%). 92.6% reached the caecum; completion was higher (96.3%) in those failing CC due to discomfort and lower in those failing due to anatomical difficulties (90.7%) or previous surgery (84.6%). Mean time to the caecum was 20.9 minutes and mean midazolam and fentanyl doses were 2.6 mg and 49.9 µg with low discomfort scores. Conclusion(s): Balloon-assisted colonoscopy is successful in >90% of patients, is well-tolerated, and is safe.
Collapse
Affiliation(s)
| | | | - Yung Diana E
- Centre for Liver & Digestive Disorders, The Royal Infirmary of Edinburgh, Edinburgh EH16 4SA, UK; (Y.D.E.); (T.K.); (P.J.N.)
| | - Fraser Christopher
- Endoscopy Unit, The Royal Infirmary of Edinburgh, Edinburgh EH16 4SA, UK;
| | - Nemeth Artur
- Department of Gastroenterology, Skane University Hospital, Lund University, 205 02 Malmö, Sweden; (N.A.); (T.E.); (W.J.G.)
| | - Trimble Kenneth
- Centre for Liver & Digestive Disorders, The Royal Infirmary of Edinburgh, Edinburgh EH16 4SA, UK; (Y.D.E.); (T.K.); (P.J.N.)
| | - Toth Ervin
- Department of Gastroenterology, Skane University Hospital, Lund University, 205 02 Malmö, Sweden; (N.A.); (T.E.); (W.J.G.)
| | - Plevris John N
- Centre for Liver & Digestive Disorders, The Royal Infirmary of Edinburgh, Edinburgh EH16 4SA, UK; (Y.D.E.); (T.K.); (P.J.N.)
| | - Wurm Johansson Gabriele
- Department of Gastroenterology, Skane University Hospital, Lund University, 205 02 Malmö, Sweden; (N.A.); (T.E.); (W.J.G.)
| |
Collapse
|
4
|
Parsa N, Vemulapalli KC, Rex DK. Performance of radiographic imaging after incomplete colonoscopy for nonmalignant causes in clinical practice. Gastrointest Endosc 2020; 91:1371-1377. [PMID: 32032619 DOI: 10.1016/j.gie.2020.01.043] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Accepted: 01/22/2020] [Indexed: 02/08/2023]
Abstract
BACKGROUND AND AIMS CT colonography (CTC) or barium enema are commonly ordered to complete colorectal imaging after an incomplete colonoscopy. We evaluated the sensitivity of radiographic studies performed for this purpose in clinical practice outside clinical trials. METHODS Adult patients referred to an expert endoscopist for incomplete colonoscopy because of a redundant colon or a difficult sigmoid and who underwent previous radiographic imaging between July 2001 and July 2019 were identified. None of the patients had a malignant obstruction as the cause of incomplete colonoscopy. Data on polyp size, location, and pathology were obtained from colonoscopy and radiology reports. Polyps identified on imaging and colonoscopy were matched based on polyp size and location. RESULTS Among 769 patients referred for incomplete colonoscopy, we identified 65 with a radiographic examination performed within 36 months of colonoscopy at our center. Per-patient sensitivity for CTC was suboptimal (70%) and was very low for barium enema (26.7%). Per-polyp sensitivity for both CTC and barium enema was poor (23.8% and 7.6%). Quality of the examination did not seem to affect procedure sensitivity. CONCLUSIONS Radiographic imaging after incomplete colonoscopy for reasons other than malignant obstruction had poor sensitivity for polyps. Patients with incomplete colonoscopies should be considered for repeat colonoscopy by an expert.
Collapse
Affiliation(s)
- Nasim Parsa
- Division of Gastroenterology and Hepatology, University of Missouri, Columbia, Missouri, USA
| | - Krishna C Vemulapalli
- Division of Gastroenterology/Hepatology, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Douglas K Rex
- Division of Gastroenterology/Hepatology, Indiana University School of Medicine, Indianapolis, Indiana, USA
| |
Collapse
|
5
|
Baltes P, Bota M, Albert J, Philipper M, Hörster HG, Hagenmüller F, Steinbrück I, Jakobs R, Bechtler M, Hartmann D, Neuhaus H, Charton JP, Mayershofer R, Hohn H, Rösch T, Groth S, Nowak T, Wohlmuth P, Keuchel M. PillCamColon2 after incomplete colonoscopy - A prospective multicenter study. World J Gastroenterol 2018; 24:3556-3566. [PMID: 30131662 PMCID: PMC6102503 DOI: 10.3748/wjg.v24.i31.3556] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Revised: 07/18/2018] [Accepted: 07/21/2018] [Indexed: 02/06/2023] Open
Abstract
AIM To evaluate the ability of PillCamColon2 to visualize colonic segments missed by incomplete optical colonoscopy (OC) and to assess the diagnostic yield.
METHODS This prospective multicentre study included 81 patients from nine centres who underwent second-generation colon capsule endoscopy (CCE) following incomplete OC performed by an experienced gastroenterologist (> 1000 colonoscopies). Patients with stenosis were excluded. According to patient preferences, CCE was performed the following day (protocol A) after staying on clear liquids and 0.75 L Moviprep in the morning or within 30 d after new split-dose Moviprep (protocol B). Boosts consisted of 0.75 L and 0.25 L Moviprep, and phospho-soda was given as a rescue if the capsule was not excreted after seven hours.
RESULTS Seventy-four patients were analysed (51% of them in group A; 49% in group B). Bowel cleansing was adequate in 67% of cases, and CCE could visualize colonic segments missed by incomplete colonoscopy in 90% of patients under protocol A and 97% of patients under protocol B (P = 0.35, n.s.). Significant polyps including adenocarcinoma were detected in 24% of cases. Detection rates for all polyps and significant polyps per patient were similar in both protocols. Polyps were found predominantly in the right colon (86%) in segments that were not reached by OC. Extracolonic findings - such as reflux esophagitis, suspected Barrett esophagus, upper GI-bleeding, gastric polyps, gastric erosions and angiectasia - were detected in eight patients. PillCamColon2 capsule was retained in the ileum of one patient (1.4%) without symptoms and removed during an uneventful resection for unknown Crohn’s disease that was diagnosed as the cause of anemia, which was the indication for colonoscopy. CCE was well tolerated. One patient suffered from self-limiting vomiting after consuming the phospho-soda.
CONCLUSION Second-generation CCE using a low-volume preparation is useful after incomplete OC, and it allows for the detection of additional relevant findings, but cleansing efficiency could be improved.
Collapse
Affiliation(s)
- Peter Baltes
- Clinic for Internal Medicine, Bethesda Krankenhaus Bergedorf, Hamburg 21029, Germany
| | - Marc Bota
- Clinic for Internal Medicine, Bethesda Krankenhaus Bergedorf, Hamburg 21029, Germany
| | - Jörg Albert
- Department of Internal Medicine I, Klinikum der JW. Goethe Universität, Frankfurt 60590, Germany
| | | | | | | | - Ingo Steinbrück
- 1st Medical Department, Asklepios Klinikum Altona, Hamburg 22763, Germany
| | - Ralf Jakobs
- Medical Clinic C, Klinikum der Stadt Ludwigshafen, Ludwigshafen 67063, Germany
| | - Matthias Bechtler
- Medical Clinic C, Klinikum der Stadt Ludwigshafen, Ludwigshafen 67063, Germany
| | - Dirk Hartmann
- Clinic for Internal Medicine, Sana Klinikum Lichtenberg, Berlin 10365, Germany
| | - Horst Neuhaus
- Clinic for Internal Medicine, Evangelisches Krankenhaus, Düsseldorf 40217, Germany
| | - Jean-Pierre Charton
- Clinic for Internal Medicine, Evangelisches Krankenhaus, Düsseldorf 40217, Germany
| | | | - Horst Hohn
- Schwerpunktpraxis Gastroenterologie, Koblenz 56068, Germany
| | - Thomas Rösch
- Clinic for Interdisciplinary Endoscopy, University Hospital Eppendorf, Hamburg 20251, Germany
| | - Stefan Groth
- Clinic for Interdisciplinary Endoscopy, University Hospital Eppendorf, Hamburg 20251, Germany
| | - Tanja Nowak
- CorporateHealth International, Hamburg 20149, Germany
| | - Peter Wohlmuth
- Biometry and Data Management, Asklepios Proresearch, Hamburg 20099, Germany
| | - Martin Keuchel
- Clinic for Internal Medicine, Bethesda Krankenhaus Bergedorf, Hamburg 21029, Germany
| |
Collapse
|
6
|
Hermans C, Zee DVD, Gilissen L. Double-Balloon Endoscopy after Incomplete Colonoscopy and Its Comparison with Computed Tomography Colonography. Clin Endosc 2018; 51:66-71. [PMID: 29316779 PMCID: PMC5806920 DOI: 10.5946/ce.2017.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2016] [Revised: 10/08/2017] [Accepted: 10/25/2017] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND/AIMS Because of the national screening program for colorectal carcinoma in The Netherlands, the number of colonoscopies has increased. In case of incomplete colonoscopy, computed tomography colonography (CTC) and double-balloon colonoscopy (DBc) are alternative options. This study evaluated cecal intubation rate and pathology detection rate in the previously unexplored part of the colon, complication rate of DBc, and CTC results after incomplete colonoscopy. METHODS Retrospective observational study in a tertiary referral hospital regarding DBc and CTC reports from cases with incomplete colonoscopy. RESULTS Sixty-three DBcs were performed after incomplete colonoscopy. Cecal intubation rate was 95%. Detection rate was 58% (5% carcinoma and 3% high-grade dysplastic adenoma). CTC preceded 54% of DBcs and 62% of CTC findings were confirmed. In 16%, a biopsy was taken, and in 60%, an intervention (mostly polypectomy) was performed. One major complication (1.5%) occurred, i.e., arterial bleeding due to polypectomy necessitating right hemicolectomy. CTC (n=213) showed a possible lesion in 35%, and could be confirmed by follow-up endoscopy or surgery in 65%. CONCLUSIONS DBc is effective and safe for completion of colon inspection in incomplete colonoscopy. In patients with a high likelihood of pathology, DBc is preferred over CTC.
Collapse
Affiliation(s)
- Carlijn Hermans
- Department of Gastroenterology and Hepatology, Catharina Hospital Eindhoven, Eindhoven, Netherlands
| | - Dennis van der Zee
- Department of Radiology, Catharina Hospital Eindhoven, Eindhoven, Netherlands
| | - Lennard Gilissen
- Department of Gastroenterology and Hepatology, Catharina Hospital Eindhoven, Eindhoven, Netherlands
| |
Collapse
|
7
|
Song KH, Lee BJ. Balloon-Assisted Endoscopy: A Powerful Tool for Complete Colonoscopy. Clin Endosc 2018; 51:3-4. [PMID: 29397651 PMCID: PMC5806909 DOI: 10.5946/ce.2018.027] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2018] [Revised: 01/18/2018] [Accepted: 01/19/2018] [Indexed: 12/21/2022] Open
Affiliation(s)
- Kyung Hwan Song
- Department of Gastroenterology, Korea University Guro Hospital, Seoul, Korea
| | - Beom Jae Lee
- Department of Gastroenterology, Korea University Guro Hospital, Seoul, Korea
| |
Collapse
|
8
|
Yung DE, Koulaouzidis A, Fraser C, Trimble KC, Plevris JN. Double-balloon colonoscopy for failed conventional colonoscopy: the Edinburgh experience and systematic review of existing data. Gastrointest Endosc 2016; 84:878-881. [PMID: 27742052 DOI: 10.1016/j.gie.2016.06.024] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2016] [Accepted: 06/12/2016] [Indexed: 12/11/2022]
Affiliation(s)
- Diana E Yung
- Centre for Liver and Digestive Disorders, The Royal Infirmary of Edinburgh, Edinburgh, UK
| | | | - Chris Fraser
- Centre for Liver and Digestive Disorders, The Royal Infirmary of Edinburgh, Edinburgh, UK
| | - Ken C Trimble
- Centre for Liver and Digestive Disorders, The Royal Infirmary of Edinburgh, Edinburgh, UK
| | - John N Plevris
- Centre for Liver and Digestive Disorders, The Royal Infirmary of Edinburgh, Edinburgh, UK
| |
Collapse
|
9
|
Abstract
PURPOSE OF REVIEW Endoscopic technology has evolved such that device-assisted enteroscopes (DAEs) are readily available and utilized to diagnose and treat patients with small bowel disease. In this review, we briefly discuss the DAE platforms and the expanding role for small bowel enteroscopy. RECENT FINDINGS The indications for small bowel endoscopy are rapidly increasing with new diagnostic and therapeutic maneuvers that are allowing patients to obtain treatments that would have otherwise required more invasive or higher risk procedures. The evolving utilization of DAE tools in patients with altered gastrointestinal anatomy and otherwise palliative conditions is allowing for more aggressive and therapeutic choices for patients who would otherwise have limited options. SUMMARY There are currently four different platforms for small bowel endoscopy each with different operational characteristics. The literature comparing double-balloon and single-balloon enteroscopy is relatively established, but there are still limited data evaluating the role of the two newer platforms (spiral and on-demand enteroscopy) in diagnostic and therapeutic small bowel endoscopy - a reflection of the potential and vast opportunities that are available in the field of small bowel enteroscopy.
Collapse
|
10
|
Bick BL, Vemulapalli KC, Rex DK. Regional center for complex colonoscopy: yield of neoplasia in patients with prior incomplete colonoscopy. Gastrointest Endosc 2016; 83:1239-44. [PMID: 26584785 DOI: 10.1016/j.gie.2015.10.053] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2015] [Accepted: 10/29/2015] [Indexed: 02/08/2023]
Abstract
BACKGROUND AND AIMS Incomplete colonoscopy increases the risk of incident proximal colon cancer postcolonoscopy. Incomplete colonoscopy is often followed by barium enema or CT colonography. We sought to describe the yield of completion colonoscopy in a regional center for complex colonoscopy. METHODS This is a retrospective cohort study of 520 consecutive patients referred to a single colonoscopist over a 14-year period for completion colonoscopy after a previous incomplete examination. RESULTS Colonoscopy was completed to the cecum in 506 of 520 patients (97.3%). A total of 913 conventional adenomas was removed in 277 patients (adenoma detection rate 53.3%). There were 184 adenomas ≥ 1 cm in size or with advanced pathology. There were 525 serrated-class lesions removed in 175 patients, including 54 sessile serrated polyps in 26 patients and 41 hyperplastic polyps greater than 1 cm in 26 patients. Nine colorectal cancers were found. We estimated that approximately 57% of the conventional adenomas, 58% of the sessile serrated polyps, 27% of the hyperplastic polyps, and all 9 cancers detected by the completion colonoscopy were beyond the extent of the previous examination. CONCLUSIONS The yield of completion colonoscopy in a cohort of patients with previous failed cecal intubation was substantial. Regional centers for complex colonoscopy can provide high rates of cecal intubation in cases of incomplete colonoscopy and high yields of lesions in these cases. The regional center for complex colonoscopy is an important medical service.
Collapse
Affiliation(s)
- Benjamin L Bick
- Department of Medicine, Division of Gastroenterology/Hepatology, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Krishna C Vemulapalli
- Department of Medicine, Division of Gastroenterology/Hepatology, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Douglas K Rex
- Department of Medicine, Division of Gastroenterology/Hepatology, Indiana University School of Medicine, Indianapolis, Indiana, USA
| |
Collapse
|
11
|
Araki A, Tsuchiya K, Watanabe M. Advances in balloon endoscopes. Clin J Gastroenterol 2015; 7:189-99. [PMID: 26183736 DOI: 10.1007/s12328-014-0485-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2014] [Accepted: 03/25/2014] [Indexed: 01/10/2023]
Abstract
In September 2003, a double-balloon endoscope (DBE) composed of balloons attached to a scope and an overtube was released in Japan prior to becoming available in other parts of the world. The DBE was developed by Dr. Yamamoto (1), and 5 different types of scopes with different uses have already been marketed. In April 2007, a single-balloon small intestinal endoscope was released with a balloon attached only to the overtube as a subsequent model. This article presents a detailed account of the development of these scopes up to the present time.
Collapse
Affiliation(s)
- Akihiro Araki
- Department of Gastroenterology and Hepatology, Graduate School, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan,
| | | | | |
Collapse
|