1
|
Yamasaki K, Dantam J, Sasanuma K, Hisamura R, Mizuno Y, Hui A, Jones L. Impact of in vitro lens deposition and removal on bacterial adhesion to orthokeratology contact lenses. Cont Lens Anterior Eye 2024; 47:102104. [PMID: 38161140 DOI: 10.1016/j.clae.2023.102104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 11/22/2023] [Accepted: 12/11/2023] [Indexed: 01/03/2024]
Abstract
PURPOSE The purpose of this study was to explore the impact of several contact lens (CL) care solutions on the removal of proteins and lipids, and how deposit removal impacts bacterial adhesion and solution disinfection. METHODS Lysozyme and lipid deposition on three ortho-k (rigid) and two soft CL materials were evaluated using an ELISA kit and gas chromatography respectively. Bacterial adhesion to a fluorosilicone acrylate material using Pseudomonas aeruginosa with various compositions of artificial tear solutions (ATS), including with denatured proteins, was also investigated. The impact of deposition of the different formulations of ATS on biofilm formation was explored using cover slips. Finally, the lysozyme and lipid cleaning efficacy and disinfection efficacy against P. aeruginosa and Staphylococcus aureus of four different contact lens care solutions were studied using qualitative analysis. RESULTS While maximum lysozyme deposition was observed with the fluorosilicone acrylate material (327.25 ± 54.25 µg/lens), the highest amount of lipid deposition was recorded with a fluoro-siloxanyl styrene material (134.71 ± 19.87 µg/lens). Adhesion of P. aeruginosa to fluorosilicone acrylate lenses and biofilm formation on cover slips were significantly greater with the addition of denatured proteins and lipids. Of the four contact lens care solutions investigated, the solution based on povidone-iodine removed both denatured lysozyme and lipid deposits and could effectively disinfect against P. aeruginosa and S. aureus when contaminated with denatured proteins and lipids. In contrast, the peroxide-based solution was able to inhibit P. aeruginosa growth only, while the two multipurpose solutions were unable to disinfect lenses contaminated with denatured proteins and lipids. CONCLUSION Bacterial adhesion and biofilm formation is influenced by components within artificial tear solutions depositing on lenses, including denatured proteins and lipids, which also affects disinfection. The ability of different solutions to remove these deposits should be considered when selecting systems to clean and disinfect ortho-k lenses.
Collapse
Affiliation(s)
| | - Jaya Dantam
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Ontario, Canada
| | | | | | - Yohei Mizuno
- Kobe Research Center, OPHTECS Corporation, Kobe, Japan
| | - Alex Hui
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Ontario, Canada; School of Optometry and Vision Science, Faculty of Medicine and Health, UNSW Sydney, Australia.
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Ontario, Canada; Centre for Eye and Vision Research (CEVR), Hong Kong Special Administrative Region, Hong Kong
| |
Collapse
|
2
|
Masoudi S, Willcox M. Development of an enzymatic method for the evaluation of protein deposition on contact lenses. BIOFOULING 2022; 38:84-99. [PMID: 35016572 DOI: 10.1080/08927014.2021.2019225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 12/09/2021] [Accepted: 12/10/2021] [Indexed: 06/14/2023]
Abstract
The aim of this study was to evaluate a new digestion method to quantify protein deposition on contact lenses. Four silicone hydrogel and one hydrogel contact lens material were incubated in lactoferrin, lysozyme, immunoglobulin A, and bovine serum albumin solutions at approximate physiological concentrations and temperature. Immobilized trypsin was used to digest the protein deposits from the contact lens surfaces. The total protein absorbed to lenses was extracted and digested using sequencing grade trypsin. The tryptic peptides were quantified using selected reaction monitoring mass spectrometry. The concentration of surface protein deposits was either lower than or the same as the total protein for all lens types and proteins. Immobilised trypsin can digest protein deposits from the surface of contact lenses. This ability to analyse the amount of protein at a contact lens surface may help in elucidating the effect of surface deposition on clinical outcomes during lens wear.
Collapse
Affiliation(s)
- Simin Masoudi
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| | - Mark Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| |
Collapse
|
3
|
Cheung S, Subbaraman LN, Ngo W, Jay GD, Schmidt TA, Jones L. Localization of full-length recombinant human proteoglycan-4 in commercial contact lenses using confocal microscopy. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2019; 31:110-122. [PMID: 31594478 DOI: 10.1080/09205063.2019.1678454] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
The aim of this study was to determine the sorption location of full-length recombinant human proteoglycan 4 (rhPRG4) tagged with fluorescein isothiocyanate (FITC) to four silicone hydrogel contact lenses [balafilcon A (PureVision, Bausch + Lomb), senofilcon A (Acuvue Oasys, Johnson & Johnson), comfilcon A (Biofinity, CooperVision), lotrafilcon B (Air Optix, Alcon)] and one conventional hydrogel lens [etafilcon A (Acuvue 2, Johnson & Johnson)], using confocal laser scanning microscopy (CLSM). Lenses (n = 3 each) were incubated under two conditions: (1) FITC-rhPRG4 solution at 300 μg/mL and (2) phosphate-buffered saline, for 1 h at 37 °C in darkness with gentle shaking. The central 4 mm of each lens was removed and viewed with the Zeiss 510 CLSM using an argon laser at 488 nm (FITC excitation 495 nm, emission 521 nm). Depth scans were taken at 1 μm intervals to a maximum depth of 100 μm. All lens materials demonstrated sorption of rhPRG4. Both senofilcon A and balafilcon A revealed FITC-rhPRG4 penetration into the bulk of the lens, generally favoring the surface. rhPRG4 was observed exclusively on the surface of lotrafilcon B, with no presence within the bulk of the lens. rhPRG4 was evenly distributed throughout the bulk of the lens, as well as on the surface, for comfilcon A and etafilcon A. The sorption profile of FITC-rhPRG4 was successfully visualized using CLSM in various contact lens materials. The polymer composition, surface treatment and pore size of the material can influence the sorption of rhPRG4.
Collapse
Affiliation(s)
- Steven Cheung
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Lakshman N Subbaraman
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - William Ngo
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Gregory D Jay
- Department of Emergency Medicine, Alpert Medical School & School of Engineering, Brown University, Providence, Rhode Island, USA
| | - Tannin A Schmidt
- Faculty of Kinesiology & Schulich School of Engineering, University of Calgary, Calgary, Alberta, Canada.,Biomedical Engineering Department, University of Connecticut Health Center, Farmington, Connecticut, USA
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| |
Collapse
|
4
|
Walther H, Phan CM, Subbaraman LN, Jones L. Differential Deposition of Fluorescently Tagged Cholesterol on Commercial Contact Lenses Using a Novel In Vitro Eye Model. Transl Vis Sci Technol 2018; 7:18. [PMID: 29644148 PMCID: PMC5892225 DOI: 10.1167/tvst.7.2.18] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2017] [Accepted: 02/17/2018] [Indexed: 11/24/2022] Open
Abstract
Purpose We evaluate the differences in lipid uptake and penetration in daily disposable (DD) contact lenses (CL) using a conventional “in-vial” method compared to a novel in vitro eye model. Methods The penetration of fluorescently labelled 22-(N-(7-Nitrobenz-2-Oxa-1,3-Diazol-4-yl)Amino)-23,24-Bisnor-5-Cholen-3beta-Ol (NBD)–cholesterol on three silicone hydrogel (SH) and four conventional hydrogel (CH) DD CLs were investigated. CLs were incubated for 4 and 12 hours in a vial, containing 3.5 mL artificial tear solution (ATS), or were mounted on an in vitro eye-blink platform designed to simulate physiologic tear flow (2 mL/24 hours), tear volume and “simulated” blinking. Subsequently, CLs were analyzed using laser scanning confocal microscopy and ImageJ. Results Penetration depth and fluorescence intensities of NBD-cholesterol varied between the incubation methods as well as lens materials. Using the traditional vial incubation method, NBD-cholesterol uptake occurred equally on both sides of all lens materials. However, using our eye-blink model, cholesterol penetration was observed primarily on the anterior surface of the CLs. In general, SH lenses showed higher intensities of NBD-cholesterol than CH materials. Conclusions The traditional “in-vial” incubation method exposes the CLs to an excessively high amount of ATS, which results in an overestimation for cholesterol deposition. Our model, which incorporates important ocular factors, such as intermittent air exposure, small tear volume, and physiological tear flow between blinks, provides a more natural environment for in vitro lens incubation. Translational Relevance In vitro measurements of CLs are a common approach to predict their interactions and performance on the eye. Traditional methods, however, are rudimentary. Therefore, this study presents a novel in vitro model to evaluate CLs, which consequently will enhance elucidations of the interactions between CLs and the eye.
Collapse
Affiliation(s)
- Hendrik Walther
- Centre for Ocular Research & Education (CORE) - formerly Centre for Contact Lens Research (CCLR), School of Optometry and Vision Science, Waterloo, Ontario, Canada
| | - Chau-Minh Phan
- Centre for Ocular Research & Education (CORE) - formerly Centre for Contact Lens Research (CCLR), School of Optometry and Vision Science, Waterloo, Ontario, Canada
| | - Lakshman N Subbaraman
- Centre for Ocular Research & Education (CORE) - formerly Centre for Contact Lens Research (CCLR), School of Optometry and Vision Science, Waterloo, Ontario, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE) - formerly Centre for Contact Lens Research (CCLR), School of Optometry and Vision Science, Waterloo, Ontario, Canada
| |
Collapse
|
5
|
In Vitro Effect of Lysozyme on Albumin Deposition to Hydrogel Contact Lens Materials. Optom Vis Sci 2017; 94:1047-1051. [PMID: 29040199 DOI: 10.1097/opx.0000000000001137] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
SIGNIFICANCE Albumin deposition on contact lenses could be detrimental to contact lens (CL) wear because this may increase the risk of bacterial binding and reduce comfort. Lysozyme deposition on selected lens materials would reduce albumin deposition on lenses. PURPOSE This study aims to determine if lysozyme deposition on CLs could act as a barrier against subsequent albumin adsorption, using an in vitro model. METHODS Six hydrogel CL materials (etafilcon A, polymacon, nelfilcon A, omafilcon A, ocufilcon B, and nesofilcon A) were evaluated. Four CLs of each type were soaked in lysozyme solution for 16 hours at 37°C. Lysozyme-coated lenses were then placed in vials with 1.5 mL of artificial tear solution containing I-labeled albumin for 16 hours at 37°C with shaking. Four uncoated lenses of each type were used as controls. Lenses soaked in radiolabeled albumin were rinsed in a phosphate-buffered saline solution, and radioactive counts were measured directly on lenses using a gamma counter. Albumin uptake on lenses was measured using a calibration curve by plotting radioactive counts versus protein concentration. RESULTS Results are reported as mean ± SD. Lysozyme-coated etafilcon A lenses exhibited lower levels of deposited albumin than uncoated etafilcon A lenses (58 ± 12 vs. 84 ± 5 ng/lens; P < .05). There were no differences in albumin adsorption between control (uncoated) and lysozyme-coated polymacon (105 ± 10 vs. 110 ± 34 ng/lens), nelfilcon A (51 ± 7 vs. 42 ± 20 ng/lens), omafilcon A (90 ± 20 vs. 80 ± 38 ng/lens), ocufilcon B (87 ± 20 vs. 115 ± 50 ng/lens), and nesofilcon A (170 ± 29 vs. 161 ± 10 ng/lens) lens materials (P > .05). Uncoated nesofilcon A lenses deposited the highest amount of albumin when compared with other uncoated lenses (P < .05). CONCLUSIONS This study demonstrates that lysozyme deposited onto etafilcon A resists the deposition of albumin, which may potentially be beneficial to CL wearers.
Collapse
|
6
|
A Review of Techniques to Measure Protein Sorption to Soft Contact Lenses. Eye Contact Lens 2017; 43:276-286. [PMID: 28198731 DOI: 10.1097/icl.0000000000000366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To compare and critically evaluate a variety of techniques to measure the quantity and biological activity of protein sorption to contact lenses over short time periods. METHODS A literature review was undertaken investigating the major techniques to measure protein sorption to soft contact lens materials, with specific reference to measuring protein directly on lenses using in situ, ex situ, protein structural, and biological activity techniques. RESULTS The use of in situ techniques to measure protein quantity provides excellent sensitivity, but many are not directly applicable to contact lenses. Many ex situ techniques struggle to measure all sorbed proteins, and these measurements can have significant signal interference from the lens materials themselves. Techniques measuring the secondary and tertiary structures of sorbed proteins have exhibited only limited success. CONCLUSIONS There are a wide variety of techniques to measure both the amount of protein and the biological activity of protein sorbed to soft contact lens materials. To measure the mass of protein sorbed to soft contact lenses (not just thin films) over short time periods, the method of choice should be I radiolabeling. This technique is sensitive enough to measure small amounts of deposited protein, provided steps are taken to limit and measure any interaction of the iodine tracer with the materials. To measure the protein activity over short time periods, the method of choice should be to measure the biological function of sorbed proteins. This may require new methods or adaptations of existing ones.
Collapse
|
7
|
Silva D, Fernandes A, Nunes T, Colaço R, Serro A. The effect of albumin and cholesterol on the biotribological behavior of hydrogels for contact lenses. Acta Biomater 2015; 26:184-94. [PMID: 26278500 DOI: 10.1016/j.actbio.2015.08.011] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2015] [Revised: 07/16/2015] [Accepted: 08/12/2015] [Indexed: 10/23/2022]
Abstract
The irritation/discomfort associated with the use of contact lenses (CLs) is often related to the eyelid-lens friction. Although the use of such devices is widespread, the information about the influence of the lacrimal fluid biomolecules on the tribological behavior of the CLs hydrogels is scarce. In this work, we investigated the effect of the presence of albumin and cholesterol in the lubricant medium, on the frictional response of two model hydrogels for CLs: a hydroxyethylmethacrylate based hydrogel, HEMA/PVP, and a silicone based one, TRIS/NVP/HEMA. Tribological experiments were done in a nanotribometer, in water and in the presence of solutions of those biomolecules. It was observed a significant increase of the friction coefficient (μ) for HEMA/PVP when the lubricant contains cholesterol, and for TRIS/NVP/HEMA when it contains albumin. Solid-state NMR and DSC analysis revealed that HEMA/PVP hydrated in cholesterol solution has a lower amount of free and loosely bound water than the hydrogel hydrated in water. Therefore, a smaller amount of water shall be released into the contact region during the friction tests with cholesterol solution, leading to a thinner film in the contact zone, and consequently to a higher μ. Concerning TRIS/NVP/HEMA, QCM-D studies showed that this hydrogel adsorbs less albumin than HEMA/PVP and that the formed film is more rigid, which can explain the increase of μ. The obtained results contribute to understand the influence of lacrimal fluid composition on the tribological behavior of CLs materials, being relevant for the selection and optimization of these devices. STATEMENT OF SIGNIFICANCE Understanding the tribological behavior of contact lenses (CLs) materials in contact with the lacrimal fluid and the role of its components is of major importance to optimize the comfort and overall success of these devices. Nevertheless, the available information on this subject in the literature is scarce. In this work, the effect of albumin and cholesterol (two of the main components of the lacrimal fluid) on the frictional response of distinct types of hydrogels suitable for CLs, is compared, for the first time. Significant differences were observed with the two molecules, depending on the material, stressing the need to further study this issue to understand, predict and optimize the in vivo performance of CLs.
Collapse
|
8
|
|
9
|
Dursch TJ, Liu DE, Oh Y, Radke CJ. Fluorescent solute-partitioning characterization of layered soft contact lenses. Acta Biomater 2015; 15:48-54. [PMID: 25484335 DOI: 10.1016/j.actbio.2014.11.046] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2014] [Revised: 11/04/2014] [Accepted: 11/25/2014] [Indexed: 11/28/2022]
Abstract
Partitioning of aqueous packaging, wetting, and care-solution agents into and out of soft contact lenses (SCLs) is important for improving wear comfort and also for characterizing lens physico-chemical properties. We illustrate both features of partitioning by application of fluorescent-solute partitioning into DAILIES TOTAL1® (delefilcon A) water-gradient SCLs, which exhibit a layered structure of a silicone-hydrogel (SiHy) core sandwiched between thin surface-gel layers. Two-photon fluorescence confocal laser-scanning microscopy and attenuated total-reflectance Fourier-transform infrared spectroscopy (ATR-FTIR) characterize the lens and assess uptake profiles of six prototypical fluorescent solutes. Comparison of solute uptake in a SiHy-core prototype lens (i.e., O2OPTIX(TM)) validates the core SiHy structure of DAILIESTOTAL1®. To establish surface-layer charge, partition coefficients and water contents are obtained for aqueous pH values of 4 and 7.4. Solute fluorescence-intensity profiles clearly confirm a layered structure for the DAILIES TOTAL1® lenses. In all cases, aqueous solute partition coefficients are greater in the surface layers than in the SiHy core, signifying higher water in the surface gels. ATR-FTIR confirms surface-layer mass water contents of 82±3%. Water uptake and hydrophilic-solute uptake at pH 4 compared with that at pH 7.4 reveal that the surface-gel layers are anionic at physiologic pH 7.4, whereas both the SiHy core and O2OPTIX™ (lotrafilcon B) are nonionic. We successfully confirm the layered structure of DAILIES TOTAL1®, consisting of an 80-μm-thick SiHy core surrounded by 10-μm-thick polyelectrolyte surface-gel layers of significantly greater water content and aqueous solute uptake compared with the core. Accordingly, fluorescent-solute partitioning in SCLs provides information on gel structure and composition, in addition to quantifying uptake and release amounts and rates.
Collapse
Affiliation(s)
- T J Dursch
- Chemical and Biomolecular Engineering Department, University of California, 101E Gilman, Berkeley, CA 94720-1462, USA
| | - D E Liu
- Chemical and Biomolecular Engineering Department, University of California, 101E Gilman, Berkeley, CA 94720-1462, USA
| | - Y Oh
- Chemical and Biomolecular Engineering Department, University of California, 101E Gilman, Berkeley, CA 94720-1462, USA
| | - C J Radke
- Chemical and Biomolecular Engineering Department, University of California, 101E Gilman, Berkeley, CA 94720-1462, USA; Vision Science Group, University of California, Berkeley, CA 94720, USA.
| |
Collapse
|
10
|
Hall B, Jones L, Forrest JA. Kinetics of Competitive Adsorption between Lysozyme and Lactoferrin on Silicone Hydrogel Contact Lenses and the Effect on Lysozyme Activity. Curr Eye Res 2014; 40:622-31. [PMID: 25251834 DOI: 10.3109/02713683.2014.946518] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE To determine the effect of competitive adsorption between lysozyme and lactoferrin on silicone hydrogel contact lenses and the effect on lysozyme activity. METHODS Three commercially available silicone hydrogel contact lens materials (senofilcon A, lotrafilcon B and balafilcon A) were examined, for time points ranging from 10 s to 2 h. Total protein deposition was determined by I(125) radiolabeling of lysozyme and lactoferrin, while the activity of lysozyme was determined by a micrococcal activity assay. RESULTS Senofilcon A and balafilcon A did not show any relevant competitive adsorption between lysozyme and lactoferrin. Lotrafilcon B showed reduced protein deposition due to competitive adsorption for lactoferrin at all time points and lysozyme after 7.5 min. Co-adsorption of lactoferrin and lysozyme decreased the activity of lysozyme in solution for senofilcon A and lotrafilcon B, but co-adsorption had no effect on the surface activity of lysozyme for all lens types investigated. CONCLUSIONS Competition between lysozyme and lactoferrin is material specific. Co-adsorption of lysozyme and lactoferrin does not affect the activity of surface-bound lysozyme but can reduce the activity of subsequently desorbed lysozyme.
Collapse
Affiliation(s)
- Brad Hall
- Centre for Contact Lens Research, School of Optometry and Vision Science , Waterloo, Ontario , Canada and
| | | | | |
Collapse
|
11
|
Hall B, Phan CM, Subbaraman L, Jones LW, Forrest J. Extraction versus In Situ Techniques for Measuring Surface-Adsorbed Lysozyme. Optom Vis Sci 2014; 91:1062-70. [DOI: 10.1097/opx.0000000000000354] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
12
|
|
13
|
|
14
|
Abstract
Microbial keratitis is a sight-threatening complication associated with contact lenses. The introduction of silicone hydrogel lens materials with increased oxygen transmission to the ocular surface has not significantly altered the incidence of microbial keratitis. These data suggest that alternate, or additional, predisposing factors involving lens wear must be addressed to reduce or eliminate these infections. The contact lens can provide a surface for microbial growth in situ and can also influence ocular surface homeostasis through effects on the tear fluid and corneal epithelium. Thus, it is intuitive that future contact lens materials could make a significant contribution to preventing microbial keratitis. Design of the "right" material to prevent microbial keratitis requires understanding the effects of current materials on bacterial virulence in the cornea and on ocular surface innate defenses. Current knowledge in each of these areas will be presented with a discussion of future directions needed to understand the influence of lens material on the pathogenesis of microbial keratitis.
Collapse
|
15
|
Abstract
PURPOSE To analyze the impact of intermittent air exposure on the in vitro deposition of two radioactive lipids on various contact lens (CL) materials, using a custom-designed model blink cell. METHODS Six different CL materials (balafilcon A, lotrafilcon B, comfilcon A, senofilcon A, etafilcon A, and omafilcon A) were mounted on the model blink cell pistons, which cycled the lenses in and out of a complex artificial tear solution (ATS) that contained a trace amount of C-cholesterol or C-phosphatidylcholine. For the short-term experiment, air-exposed lenses were continuously cycled in and out of the ATS for 10 h. Longer term incubations for 6 days were tested with lotrafilcon B and balafilcon A materials incubated in C-cholesterol ATS. The air-exposed CLs were cycled for 14 h then submerged for 10 h each day. For both experiments, the control lenses were submerged for the entire test period. After incubation, lenses were processed, and deposited masses were quantified. RESULTS Exposure to air resulted in increased amounts of cholesterol deposited by 1.6 to 4.3 fold on omafilcon A, balafilcon A, comfilcon A, and senofilcon A (p ≤ 0.03) compared with submerged lenses. No differences in deposition were observed for etafilcon A and lotrafilcon B (p > 0.05). The longer term incubation of lotrafilcon B and balafilcon A showed statistically significant increases in cholesterol deposition for both air-exposed lens materials (p < 0.02) with the increase in deposition 1.8× and 2.8×, respectively. For phosphatidylcholine, all air-exposed lenses had increased masses of deposition. These deposits were statistically greater by 1.1 to 1.6 times for omafilcon A, comfilcon A, lotrafilcon B, and senofilcon A (p < 0.04), but not statistically different for etafilcon A or balafilcon A (p > 0.05). CONCLUSIONS This study found that lipid deposition profiles are CL material dependent and that intermittent air exposure can influence the mass of lipid deposited.
Collapse
|
16
|
Material properties that predict preservative uptake for silicone hydrogel contact lenses. Eye Contact Lens 2013; 38:350-7. [PMID: 23085619 DOI: 10.1097/icl.0b013e318272c470] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To assess material properties that affect preservative uptake by silicone hydrogel lenses. METHODS We evaluated the water content (using differential scanning calorimetry), effective pore size (using probe penetration), and preservative uptake (using high-performance liquid chromatography with spectrophotometric detection) of silicone and conventional hydrogel soft contact lenses. RESULTS Lenses grouped similarly based on freezable water content as they did based on total water content. Evaluation of the effective pore size highlighted potential differences between the surface-treated and non-surface-treated materials. The water content of the lens materials and ionic charge are associated with the degree of preservative uptake. CONCLUSIONS The current grouping system for testing contact lens-solution interactions separates all silicone hydrogels from conventional hydrogel contact lenses. However, not all silicone hydrogel lenses interact similarly with the same contact lens solution. Based upon the results of our research, we propose that the same material characteristics used to group conventional hydrogel lenses, water content and ionic charge, can also be used to predict uptake of hydrophilic preservatives for silicone hydrogel lenses. In addition, the hydrophobicity of silicone hydrogel contact lenses, although not investigated here, is a unique contact lens material property that should be evaluated for the uptake of relatively hydrophobic preservatives and tear components.
Collapse
|
17
|
Ng A, Heynen M, Luensmann D, Subbaraman LN, Jones L. Impact of tear film components on the conformational state of lysozyme deposited on contact lenses. J Biomed Mater Res B Appl Biomater 2013; 101:1172-81. [PMID: 23564739 DOI: 10.1002/jbm.b.32927] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2012] [Revised: 12/06/2012] [Accepted: 01/30/2013] [Indexed: 11/07/2022]
Affiliation(s)
- Alan Ng
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| | - Miriam Heynen
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| | - Doerte Luensmann
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| | - Lakshman N. Subbaraman
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| | - Lyndon Jones
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| |
Collapse
|
18
|
|
19
|
Weeks A, Morrison D, Alauzun JG, Brook MA, Jones L, Sheardown H. Photocrosslinkable hyaluronic acid as an internal wetting agent in model conventional and silicone hydrogel contact lenses. J Biomed Mater Res A 2012; 100:1972-82. [PMID: 22566397 DOI: 10.1002/jbm.a.33269] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2011] [Accepted: 04/27/2011] [Indexed: 11/06/2022]
Abstract
Photocrosslinkable methacrylated hyaluronic acid (HA) was prepared and incorporated into model conventional and silicone hydrogel contact lenses as an internal wetting agent. The molecular weight of the HA, the degree of methacrylation as well as the amount (0.25 to 1.0 wt %) incorporated were varied. The HA-containing hydrogels were analyzed using a variety of techniques including water contact angles, equilibrium water content (EWC), and lysozyme sorption. The presence of HA could be detected in the materials using X-ray photoelectron spectroscopy and Fourier transform infrared spectroscopy-attenuated total reflectance. The materials containing methacrylated HA had improved hydrophilicity and reduced lysozyme sorption. Effects of modified HA on EWC were dependent upon the materials but generally increased water uptake. Increased mobility of the HA associated with a lower molecular weight and lower degree of methacrylation was found to be more effective in improving hydrophilicity and decreasing lysozyme sorption than the less mobile HA. All results found suggest that photocrosslinkable HA has significant potential in contact lens applications.
Collapse
Affiliation(s)
- Andrea Weeks
- School of Biomedical Engineering, McMaster University, 1280 Main St. West, Hamilton, Ontario
| | | | | | | | | | | |
Collapse
|
20
|
Weeks A, Boone A, Luensmann D, Jones L, Sheardown H. The effects of hyaluronic acid incorporated as a wetting agent on lysozyme denaturation in model contact lens materials. J Biomater Appl 2012; 28:323-33. [PMID: 22561981 DOI: 10.1177/0885328212446936] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Conventional and silicone hydrogels as models for contact lenses were prepared to determine the effect of the presence of hyaluronic acid on lysozyme sorption and denaturation. Hyaluronic acid was loaded into poly(2-hydroxyethyl methacrylate) and poly(2-hydroxyethyl methacrylate)/TRIS--methacryloxypropyltris (trimethylsiloxy silane) hydrogels, which served as models for conventional and silicone hydrogel contact lens materials. The hyaluronic acid was cross-linked using 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide in the presence of dendrimers. Active lysozyme was quantified using a Micrococcus lysodeikticus assay while total lysozyme was determined using 125-I radiolabeled protein. To examine the location of hyaluronic acid in the gels, 6-aminofluorescein labeled hyaluronic acid was incorporated into the gels using 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide chemistry and the gels were examined using confocal laser scanning microscopy. Hyaluronic acid incorporation significantly reduced lysozyme sorption in poly(2-hydroxyethyl methacrylate) (p < 0.00001) and poly(2-hydroxyethyl methacrylate)/TRIS--methacryloxypropyltris (trimethylsiloxy silane) (p < 0.001) hydrogels, with the modified materials sorbing only 20% and 16% that of the control, respectively. More importantly, hyaluronic acid also decreased lysozyme denaturation in poly(2-hydroxyethyl methacrylate) (p < 0.005) and poly(2-hydroxyethyl methacrylate)/TRIS--methacryloxypropyltris (trimethylsiloxy silane) (p < 0.02) hydrogels. The confocal laser scanning microscopy results showed that the hyaluronic acid distribution was dependent on both the material type and the molecular weight of hyaluronic acid. This study demonstrates that hyaluronic acid incorporated as a wetting agent has the potential to reduce lysozyme sorption and denaturation in contact lens applications. The distribution of hyaluronic acid within hydrogels appears to affect denaturation, with more surface mobile, lower molecular weight hyaluronic acid being more effective in preventing denaturation.
Collapse
Affiliation(s)
- Andrea Weeks
- School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada
| | | | | | | | | |
Collapse
|
21
|
Protein deposition on contact lenses: The past, the present, and the future. Cont Lens Anterior Eye 2012; 35:53-64. [DOI: 10.1016/j.clae.2011.12.005] [Citation(s) in RCA: 119] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2010] [Revised: 12/18/2011] [Accepted: 12/24/2011] [Indexed: 11/19/2022]
|
22
|
Weeks A, Luensmann D, Boone A, Jones L, Sheardown H. Hyaluronic acid as an internal wetting agent in model DMAA/TRIS contact lenses. J Biomater Appl 2011; 27:423-32. [DOI: 10.1177/0885328211410999] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Model silicone hydrogel contact lenses, comprised of N,N-dimethylacrylamide and methacryloxypropyltris (trimethylsiloxy) silane, were fabricated and hyaluronic acid (HA) was incorporated as an internal wetting agent using a dendrimer-based method. HA and dendrimers were loaded into the silicone hydrogels and cross-linked using 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide chemistry. The presence and location of HA in the hydrogels was confirmed using X-ray photoelectron spectroscopy and confocal laser scanning microscopy, respectively. The effects of the presence of HA on the silicone hydrogels on hydrophilicity, swelling behavior, transparency, and lysozyme sorption and denaturation were evaluated. The results showed that HA increased the hydrophilicity and the equilibrium water content of the hydrogels without affecting transparency. HA also significantly decreased the amount of lysozyme sorption ( p < 0.002). HA had no effect on lysozyme denaturation in hydrogels containing 0% and 1.7% methacrylic acid (MAA) (by weight) but when the amount of MAA was increased to 5%, the level of lysozyme denaturation was significantly lower compared to control materials. These results suggest that HA has great potential to be used as a wetting agent in silicone hydrogel contact lenses to improve wettability and to decrease lysozyme sorption and denaturation.
Collapse
Affiliation(s)
- Andrea Weeks
- School of Biomedical Engineering, McMaster University, Hamilton ON Canada
| | | | - Adrienne Boone
- School of Optometry, University of Waterloo, Waterloo ON Canada
| | - Lyndon Jones
- School of Biomedical Engineering, McMaster University, Hamilton ON Canada
- School of Optometry, University of Waterloo, Waterloo ON Canada
- Department of Chemical Engineering, McMaster University, Hamilton ON Canada
| | - Heather Sheardown
- School of Biomedical Engineering, McMaster University, Hamilton ON Canada
- School of Optometry, University of Waterloo, Waterloo ON Canada
- Department of Chemical Engineering, McMaster University, Hamilton ON Canada
| |
Collapse
|
23
|
Luensmann D, Jones L. Impact of fluorescent probes on albumin sorption profiles to ophthalmic biomaterials. J Biomed Mater Res B Appl Biomater 2010; 94:327-336. [PMID: 20574970 DOI: 10.1002/jbm.b.31655] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Bovine serum albumin (BSA) was conjugated to three organic fluorescent probes, 5-(4,6-dichloro-s-triazin-2-ylamino)fluorescein hydrochloride (DTAF), Rhodamine B isothiocyanate (RITC), and Lucifer yellow VS (LY). The protein sorption profile to one pHEMA-based (etafilcon A) and three silicone hydrogel (SH) contact lens types (lotrafilcon B, balafilcon A and senofilcon A) was determined using confocal laser scanning microscopy. In addition, all lenses were incubated in dye solutions containing the fluorescent probe alone; and in a separate experiment BSA accumulation was quantified using radiolabeling. The different fluorescent conjugates showed similar sorption profiles for the pHEMA-based lens, but marked differences for all SH lenses. Lotrafilcon B accumulated more protein on the surface as compared to the matrix, independent of the fluorescent probe used for conjugation. Protein sorption varied for senofilcon A, with DTAF-BSA sorbing primarily to the surface region, while the other conjugates penetrated in equal amounts into the matrix. Balafilcon A exhibited smaller differences between conjugates, with LY-BSA allowing the protein to fully penetrate the matrix, while the other conjugates showed minor surface adsorption. Sorption curves of unbound dyes were often similar compared to the conjugated results. BSA profiles to pHEMA-based and silicone hydrogel lenses were highly dependent on the fluorescent probe used and none of the probes accurately reflected quantitative protein levels for the lens materials investigated.
Collapse
Affiliation(s)
- Doerte Luensmann
- School of Optometry, Centre for Contact Lens Research, University of Waterloo, Waterloo, Ontario N2L3G1, Canada.
| | | |
Collapse
|
24
|
|
25
|
Luensmann D, Zhang F, Subbaraman L, Sheardown H, Jones L. Localization of Lysozyme Sorption to Conventional and Silicone Hydrogel Contact Lenses Using Confocal Microscopy. Curr Eye Res 2009; 34:683-97. [DOI: 10.1080/02713680903015900] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
26
|
Care Regimen and Lens Material Influence on Silicone Hydrogel Contact Lens Deposition. Optom Vis Sci 2009; 86:251-9. [DOI: 10.1097/opx.0b013e318196a74b] [Citation(s) in RCA: 67] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
27
|
Efficacy of an Extraction Solvent Used to Quantify Albumin Deposition on Hydrogel Contact Lens Materials. Eye Contact Lens 2009; 35:76-80. [DOI: 10.1097/icl.0b013e318199aff6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
28
|
Albumin adsorption to contact lens materials: A review. Cont Lens Anterior Eye 2008; 31:179-87. [DOI: 10.1016/j.clae.2008.05.004] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2007] [Revised: 05/12/2008] [Accepted: 05/15/2008] [Indexed: 11/21/2022]
|