1
|
Das A, Sil A, Kumar P, Neema S. Chronic venous insufficiency: Part 2 Diagnosis and treatment. Clin Exp Dermatol 2022; 47:1240-1255. [PMID: 35212409 DOI: 10.1111/ced.15152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2021] [Revised: 02/12/2022] [Accepted: 02/23/2022] [Indexed: 11/28/2022]
Abstract
Chronic venous insufficiency (CVI) is a common medical condition that results from venous hypertension of the extremities, leading to significant morbidity. The diagnosis of CVI is quite straightforward from patient history and obvious clinical manifestations. In the recent past, availability of various invasive and non-invasive modalities have assisted in evaluation of such cases. Although compression therapy is the mainstay of management, newer surgical and other interventional techniques are now being considered for patients who do not respond to conventional medical management. This review article will outline a diagnostic approach in cases of CVI and discuss the management principles encompassing conservative, pharmacological, and interventional options.
Collapse
Affiliation(s)
- Anupam Das
- Department of Dermatology, Venereology, and Leprosy; KPC Medical College & Hospital, Kolkata, India Consultant Dermatologist, Katihar, Bihar, India
| | - Abheek Sil
- Department of Dermatology, Venereology, and Leprosy; RG Kar Medical College & Hospital, Kolkata, India
| | | | - Shekhar Neema
- Department of Dermatology, Venereology, and Leprosy; Armed Forces Medical College, Pune, India
| |
Collapse
|
2
|
Morisaka H, Matsuura K, Yamaguchi H, Ichikawa T, Onishi H. Effect of decreased contrast injection flow rate on aortic enhancement in 80-KV peak CT with contrast dose reduction. Acta Radiol 2021; 64:353-359. [PMID: 34923851 DOI: 10.1177/02841851211067144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Effect of decreased injection flow rate of contrast agent at the same iodine dose and delivery rate on aortic enhancement has not been clearly elucidated. PURPOSE To evaluate the effect of decreased injection flow rate of contrast agent on aortic peak enhancement in a dynamic flow phantom and on aortic enhancement in clinical dynamic 80-kVp computed tomography (CT) with contrast dose reduction. MATERIAL AND METHODS In the dynamic flow phantom experiment, the effect of a decreased injection flow rate at the same total iodine dose and delivery rate on simulated aortic peak enhancement was evaluated. In the clinical retrospective study, we searched 312 patients with renal dysfunction who underwent an 80-kVp abdominal dynamic CT with 40% reduction of contrast agent from a standard 120-kVp protocol and measured the aortic enhancement at the level of the hepatic hilum. Independent predictors for aortic enhancement were determined by multiple linear regression analysis, and after adjustment of significant predictors, independent variables for acquiring optimal aortic enhancement, ≥300 HU, were determined by multiple logistic regression analysis. RESULTS In the phantom experiment, decreased flow rate showed a significant but small descent effect (6%-9%) on simulated aortic peak enhancement. In the multiple linear regression analysis, only age was an independent predictor of aortic enhancement; there was no independent predictor for optimal age-adjusted aortic enhancement of ≥300 HU. CONCLUSIONS Decreased injection flow rate had a small influence on aortic enhancement in vitro but had no significant effect on the aortic enhancement in clinical dynamic 80-kVp CT.
Collapse
Affiliation(s)
- Hiroyuki Morisaka
- Department of Radiology, University of Yamanashi, Chuo, Yamanashi, Japan
- Diagnostic Radiology, Saitama Medical University International Medical Center, Hidaka, Saitama, Japan
| | - Koichiro Matsuura
- Diagnostic Radiology, Saitama Medical University International Medical Center, Hidaka, Saitama, Japan
| | - Haruomi Yamaguchi
- Department of Radiology, Graduate School of Medicine, University of Tokyo, Bunkyo-ku, Tokyo, Japan
| | - Tomoaki Ichikawa
- Department of Diagnostic Radiology and Nuclear Medicine, Gunma University Graduate School of Medicine, Maebashi, Gunma, Japan
| | - Hiroshi Onishi
- Department of Radiology, University of Yamanashi, Chuo, Yamanashi, Japan
| |
Collapse
|
3
|
Tschauner S, Marterer R, Nagy E, Singer G, Riccabona M, Sorantin E. Experiences with image quality and radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in pediatric extremity trauma. Skeletal Radiol 2020; 49:1939-1949. [PMID: 32535775 PMCID: PMC7652807 DOI: 10.1007/s00256-020-03506-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 06/03/2020] [Accepted: 06/04/2020] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Novel dedicated extremity cone beam computed tomography (CBCT) devices, recently introduced to the market, raised attention as a possible alternative in advanced diagnostic pediatric trauma imaging, today usually performed by multidetector computed tomography (MDCT). This work aimed to compare image quality and radiation dose of CBCT and MDCT. MATERIALS AND METHODS Fifty-four CBCT-MDCT examination pairs, containing nine MDCTs acquired in parallel prospectively and 45 MDCTs matched in retrospect, were included in this study. Image quality was analyzed semi-objectively by measuring noise, contrast-to-noise ratio (CNR), and signal-to-noise ratios (SNR) and subjectively by performing image impression ratings. CT dose records were readout. RESULTS Image noise was significantly lower in CBCT compared with MDCT, both semi-objectively and subjectively (both p < 0.001). CNR and SNRs were also in favor of CBCT, though CBCT examinations exhibited significantly more beam hardening artifacts that diminished the advantages of the superior semi-objective image quality. These artifacts were believed to occur more often in children due to numerous bone-cartilage transitions in open growth plates and may have led to a better subjective diagnostic certainty rating (p = 0.001). Motion artifacts were infrequently, but exclusively observed in CBCT. CT dose index (CTDIvol) was substantially lower in CBCT (p < 0.001). CONCLUSION Dedicated extremity CBCT could be an alternative low-dose modality in the diagnostic pathway of pediatric fractures. At lower doses compared with MDCT and commonly affected by beam hardening artifacts, semi-objective CBCT image quality parameters were generally better than in MDCT.
Collapse
Affiliation(s)
- Sebastian Tschauner
- Division of Pediatric Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 34, 8036, Graz, Austria.
| | - Robert Marterer
- Division of Pediatric Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 34, 8036, Graz, Austria
| | - Eszter Nagy
- Division of Pediatric Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 34, 8036, Graz, Austria
| | - Georg Singer
- Department of Paediatric and Adolescent Surgery, Medical University of Graz, Auenbruggerplatz 34, Graz, 8036, Austria
| | - Michael Riccabona
- Division of Pediatric Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 34, 8036, Graz, Austria
| | - Erich Sorantin
- Division of Pediatric Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 34, 8036, Graz, Austria
| |
Collapse
|
4
|
Youn YJ, Lee J. Chronic venous insufficiency and varicose veins of the lower extremities. Korean J Intern Med 2019; 34:269-283. [PMID: 30360023 PMCID: PMC6406103 DOI: 10.3904/kjim.2018.230] [Citation(s) in RCA: 107] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Accepted: 09/08/2018] [Indexed: 12/15/2022] Open
Abstract
Chronic venous insufficiency (CVI) of the lower extremities manifests itself in various clinical spectrums, ranging from asymptomatic but cosmetic problems to severe symptoms, such as venous ulcer. CVI is a relatively common medical problem but is often overlooked by healthcare providers because of an underappreciation of the magnitude and impact of the problem, as well as incomplete recognition of the various presenting manifestations of primary and secondary venous disorders. The prevalence of CVI in South Korea is expected to increase, given the possible underdiagnoses of CVI, the increase in obesity and an aging population. This article reviews the pathophysiology of CVI of the lower extremities and highlights the role of duplex ultrasound in its diagnosis and radiofrequency ablation, and iliac vein stenting in its management.
Collapse
Affiliation(s)
- Young Jin Youn
- Division of Cardiology, Department of Internal Medicine, Yonsei University Wonju College of Medicine, Wonju, Korea
- Division of Interventional Cardiology, Calhoun Cardiology Center, UConn Health, University of Connecticut School of Medicine, Farmington, CT, USA
| | - Juyong Lee
- Division of Interventional Cardiology, Calhoun Cardiology Center, UConn Health, University of Connecticut School of Medicine, Farmington, CT, USA
| |
Collapse
|
5
|
Sasaki T, Fujimoto Y, Ishitoya S, Nabaa B, Watanabe N, Yamaki T, Takahashi K. Improved detectability of thromboses of the lower limb using low kilovoltage computed tomography. Medicine (Baltimore) 2018; 97:e9775. [PMID: 29419670 PMCID: PMC5944700 DOI: 10.1097/md.0000000000009775] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/21/2023] Open
Abstract
To determine the utility of low kilovoltage computed tomographic venography (CTV) for the detection of deep venous thrombus in the lower limbs.Twenty-one thrombi in 19 enrolled patients were investigated in this retrospective study. Patients were initially scanned using CTV at 100 kVp, at the femur level, followed by an immediate switch to 80 kVp. We assessed the CT values of thrombi and veins and performed subjective evaluation for detecting thrombi using a 5-point scoring system: 1, unable to evaluate due to noise or artifacts; 2, equivocal venous thrombus; 3, possible venous thrombus; 4, probable venous thrombus; and 5, definite venous thrombus.Venous density on 100-kVp images (mean ± SD [standard deviation]: 122 ± 23 HU, 95% confidence interval [CI]: 111-133 Hounsfield unit [HU]) was significantly lower than that on 80-kVp images (136 ± 24 HU, 95% CI: 125-147 HU, P < .001). There was no significant difference in thrombi between 100-kVp images (55 ± 14 HU, 95% CI: 49-61 HU) and 80-kVp images (57 ± 16, 95% CI: 50-64 HU, P = .168). The thrombus to vein ratio on 100-kVp images (0.47 ± 0.20, 95% CI: 0.39-0.56) was significantly higher than that on 80-kVp images (0.44 ± 0.16, 95% CI: 0.37-0.51, P = .048). The mean 5-point score was significantly higher on the 80-kVp images (4.76) than on the 100-kVp images (4.45, P = .016).Lower kilovoltage CTV significantly improved thrombotic to venous contrasts in the lower limbs.
Collapse
|
6
|
Song I, Yi JG, Park JH, Ko SM. Indirect CT Venography at 80 kVp with Sinogram-Affirmed Iterative Reconstruction Compared to 120 kVp with Filtered Back Projection: Assessment of Image Quality and Radiation Dose. PLoS One 2016; 11:e0163416. [PMID: 27662618 PMCID: PMC5035093 DOI: 10.1371/journal.pone.0163416] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2016] [Accepted: 09/08/2016] [Indexed: 11/30/2022] Open
Abstract
Objective To evaluate the image quality and radiation dose of indirect computed tomographic venography (CTV) using 80 kVp with sinogram-affirmed iterative reconstruction (SAFIRE) and 120 kVp with filtered back projection (FBP). Materials and Methods This retrospective study was approved by our institution and informed consent was waived. Sixty-one consecutive patients (M: F = 27: 34, mean age 60 ± 16, mean BMI 23.6 ± 3.6 kg/m2) underwent pelvic and lower extremity CTVs [group A (n = 31, 120 kVp, reconstructed with FBP) vs. group B (n = 30, 80 kVp, reconstructed with SAFIRE)]. The vascular enhancement, image noise, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were compared. Subjective image analysis for image quality and noise was performed by two radiologists. Radiation dose was compared between the two groups. Results Compared with group A, higher mean vascular enhancement was observed in the group B (group A vs. B, 118.8 ± 15.7 HU vs. 178.6 ± 39.6 HU, p < 0.001), as well as image noise (12.0 ± 3.8 HU vs. 17.9 ± 6.1 HU, p < 0.001) and CNR (5.1 ± 1.9 vs. 7.6 ± 3.0, p < 0.001). The SNRs were not significantly different in both groups (11.2 ± 4.8 vs. 10.8 ± 3.7, p = 0.617). There was no significant difference in subjective image quality between the two groups (all p > 0.05). The subjective image noise was higher in the group B (p = 0.036 in reader 1, p = 0.005 in reader 2). The inter-observer reliability for assessing subjective image quality was good (ICC 0.746~0.784, p < 0.001). The mean CT dose index volume (CTDIvol) and mean dose length product (DLP) were significantly lower in group B than group A [CTDIvol, 6.4 ± 1.3 vs. 2.2 ± 2.2 mGy (p < 0.001); DLP, 499.1 ± 116.0 vs. 133.1 ± 45.7 mGy × cm (p < 0.001)]. Conclusions CTV using 80 kVp combined with SAFIRE provides lower radiation dose and improved CNR compared to CTV using 120 kVp with FBP.
Collapse
Affiliation(s)
- Inyoung Song
- Department of Radiology, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, 143–729, Korea
| | - Jeong Geun Yi
- Department of Radiology, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, 143–729, Korea
- * E-mail:
| | - Jeong Hee Park
- Department of Radiology, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, 143–729, Korea
| | - Sung Min Ko
- Department of Radiology, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, 143–729, Korea
| |
Collapse
|
7
|
Kim JH, Choo KS, Moon TY, Lee JW, Jeon UB, Kim TU, Hwang JY, Yun MJ, Jeong DW, Lim SJ. Comparison of the image qualities of filtered back-projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction for CT venography at 80 kVp. Eur Radiol 2015; 26:2055-63. [PMID: 26486938 DOI: 10.1007/s00330-015-4060-1] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2015] [Revised: 09/28/2015] [Accepted: 10/06/2015] [Indexed: 11/25/2022]
Abstract
PURPOSE To evaluate the subjective and objective qualities of computed tomography (CT) venography images at 80 kVp using model-based iterative reconstruction (MBIR) and to compare these with those of filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR) using the same CT data sets. MATERIALS AND METHODS Forty-four patients (mean age: 56.1 ± 18.1) who underwent 80 kVp CT venography (CTV) for the evaluation of deep vein thrombosis (DVT) during 4 months were enrolled in this retrospective study. The same raw data were reconstructed using FBP, ASIR, and MBIR. Objective and subjective image analysis were performed at the inferior vena cava (IVC), femoral vein, and popliteal vein. RESULTS The mean CNR of MBIR was significantly greater than those of FBP and ASIR and images reconstructed using MBIR had significantly lower objective image noise (p < .001). Subjective image quality and confidence of detecting DVT by MBIR group were significantly greater than those of FBP and ASIR (p < .005), and MBIR had the lowest score for subjective image noise (p < .001). CONCLUSION CTV at 80 kVp with MBIR was superior to FBP and ASIR regarding subjective and objective image qualities. KEY POINTS • MBIR provides superior image quality compared with FBP and ASIR • CTV at 80kVp with MBIR improves diagnostic confidence in diagnosing DVT • CTV at 80kVp with MBIR presents better image quality with low radiation.
Collapse
Affiliation(s)
- Jin Hyeok Kim
- Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Pusan, Korea
| | - Ki Seok Choo
- Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Pusan, Korea.
| | - Tae Yong Moon
- Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Pusan, Korea
| | - Jun Woo Lee
- Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Pusan, Korea
| | - Ung Bae Jeon
- Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Pusan, Korea
| | - Tae Un Kim
- Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Pusan, Korea
| | - Jae Yeon Hwang
- Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Pusan, Korea
| | - Myeong-Ja Yun
- Department of Preventive and Occupational Medicine, School of Medicine, Pusan National University, Pusan, Korea
| | - Dong Wook Jeong
- Department of Family Medicine, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Pusan, Korea
| | - Soo Jin Lim
- Department of Cardiology, Kimhae Jungang Hospital, Gyeongsangnam-do, Korea
| |
Collapse
|
8
|
Affiliation(s)
- Robert T. Eberhardt
- From the Cardiovascular Medicine Center, Boston Medical Center, Boston, MA (R.T.E.); Boston University School of Medicine, Boston, MA (R.T.E.); Vascular Surgery, Boston VA Health Care System, Boston, MA (J.D.R.); and Harvard Medical School, Boston, MA (J.D.R.)
| | - Joseph D. Raffetto
- From the Cardiovascular Medicine Center, Boston Medical Center, Boston, MA (R.T.E.); Boston University School of Medicine, Boston, MA (R.T.E.); Vascular Surgery, Boston VA Health Care System, Boston, MA (J.D.R.); and Harvard Medical School, Boston, MA (J.D.R.)
| |
Collapse
|