Hasse FC, Giannakis A, Wehrse E, Stiller W, Wallwiener M, Kauczor HU, Weber TF, Heil J, Mokry T. Improvement of Breast Cancer Detection Using Dual-Layer Spectral CT. Diagnostics (Basel) 2024; 14:1560. [PMID: 39061697 PMCID: PMC11275589 DOI: 10.3390/diagnostics14141560] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2024] [Revised: 07/04/2024] [Accepted: 07/15/2024] [Indexed: 07/28/2024] Open
Abstract
This study aimed to investigate the diagnostic performance of breast mass detection on monoenergetic image data at 40 keV (MonoE40) and on iodine maps (IM) compared with conventional image data (CI). In this prospective single-center case-control study, 50 breast cancer patients were examined using contrast-enhanced dual-layer spectral CT. For qualitative and quantitative comparison of MonoE40 and IM with CI image data, four blinded, independent readers assessed 300 randomized single slices (two slices for each imaging type per case) with or without cancerous lesions for the presence of a breast mass. Detection sensitivity and specificity were calculated and readers rated their subjective diagnostic certainty. For statistical analysis of sensitivity and specificity, a paired t-test and ANOVA were used (significance level p = 0.05). A total of 50 female patients (median age 51 years, range 28-83 years) participated. IM had the highest overall scores in sensitivity and specificity for breast cancer detection, with 0.97 ± 0.06 and 0.95 ± 0.07, respectively, compared with 0.90 ± 0.04 and 0.92 ± 0.06 in CI. MonoE40 yielded a sensitivity of 0.96 ± 0.02 and specificity of 0.94 ± 0.08. All differences in sensitivity and specificity between MonoE or IM and CI were statistically significant (p < 0.001). The superiority of IM sensitivity and specificity was most pronounced in patients with dense breasts. Spectral CT improved the detection of breast cancer with higher sensitivity and specificity compared to conventional image data in our study.
Collapse
Affiliation(s)
- Felix Christian Hasse
- Diagnostic and Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120 Heidelberg, Germany (T.F.W.)
| | - Athanasios Giannakis
- Diagnostic and Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120 Heidelberg, Germany (T.F.W.)
| | - Eckhard Wehrse
- Division of Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
| | - Wolfram Stiller
- Diagnostic and Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120 Heidelberg, Germany (T.F.W.)
| | - Markus Wallwiener
- Department of Obstetrics and Gynecology, Heidelberg University Hospital, Im Neuenheimer Feld 440, 69120 Heidelberg, Germany
| | - Hans-Ulrich Kauczor
- Diagnostic and Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120 Heidelberg, Germany (T.F.W.)
| | - Tim F. Weber
- Diagnostic and Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120 Heidelberg, Germany (T.F.W.)
| | - Jörg Heil
- Heidelberg Breast Centre St. Elisabeth Clinic, Max-Reger-Straße 5, 69121 Heidelberg, Germany
| | - Theresa Mokry
- Diagnostic and Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120 Heidelberg, Germany (T.F.W.)
- Division of Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
| |
Collapse
|
2
|
Gong M, Liu L, Ren H, He P, Ran X, Xu Y, Zou Y, Wu J, Li Z, Tan W, Zhang Z, Li K. Value of the virtual monoenergetic image from dual-layer dual-energy computed tomography enterography in the preoperative assessment of the internal penetrating complication of Crohn's disease. Abdom Radiol (NY) 2024; 49:814-822. [PMID: 38150141 DOI: 10.1007/s00261-023-04148-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Revised: 11/13/2023] [Accepted: 12/04/2023] [Indexed: 12/28/2023]
Abstract
BACKGROUND To determine the utility of virtual-monoenergetic imaging (VMI) at low energy levels from contrast-enhanced dual-layer dual-energy (DLDE) computed tomography enterography (CTE) in the preoperative assessment of internal penetrating lesions of Crohn's disease (CD). MATERIALS AND METHODS Thirty-eight patients with penetrating lesions of CD by surgery undergoing contrast-enhanced DLDE CTE were retrospectively included. Polyenergetic imaging (PEI) and VMIs at low energy levels [40-70 kiloelectron volts (keV)] with 10 keV intervals were reconstructed. The objective parameters of image quality [noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)] and the subjective parameter of image quality [diagnostic performance of lesions (DPL), overall image quality(OIQ)] of PEI and all VMIs at the low energy level were compared to determine the VMI on the optimal energy level. The lesion detection capability between PEI and the optimal VMI was compared. RESULTS VMI40 was determined to be the optimal VMI among all VMIs at the low energy level for owning the best image quality. No significant difference was found in the detecting capability in penetrating lesions between VMI40 and PEI (p = 1.0), whereas a significant difference was found in the detecting capability in the bowel origin of the penetrating lesions (p = 0.004), the involved organ or structure by the fistula (p = 0.016) and the orifice of the fistula connected to the involved organ or structure ( p = 0.031) between them. CONCLUSIONS Compared to conventional PEI, VMI40 improves the detection capability in anatomical details of penetrating lesions of CD, helping colorectal surgeons rationalizing preoperative plans of internal penetrating lesions of CD.
Collapse
Affiliation(s)
- Meilin Gong
- Department of Radiology, Chongqing General Hospital, 118 Xingguang Street, Yubei District, Chongqing, 400000, ChongQing Province, China
| | - Lili Liu
- Department of Radiology, Chongqing General Hospital, 118 Xingguang Street, Yubei District, Chongqing, 400000, ChongQing Province, China
| | - Huanhuan Ren
- Department of Radiology, Chongqing University Cancer Hospital and Chongqing Cancer Institute and Chongqing Cancer Hospital, Chongqing, China
| | - Peipei He
- Department of Radiology, Chongqing General Hospital, 118 Xingguang Street, Yubei District, Chongqing, 400000, ChongQing Province, China
| | - Xiong Ran
- Department of Radiology, Chongqing General Hospital, 118 Xingguang Street, Yubei District, Chongqing, 400000, ChongQing Province, China
| | - Yu Xu
- Department of Radiology, Chongqing General Hospital, 118 Xingguang Street, Yubei District, Chongqing, 400000, ChongQing Province, China
| | - Ya Zou
- Department of Radiology, Chongqing General Hospital, 118 Xingguang Street, Yubei District, Chongqing, 400000, ChongQing Province, China
| | - Jingsong Wu
- Department of General Surgery, Chongqing General Hospital, Chongqing, China
| | - Zan Li
- Department of Pathology, Chongqing General Hospital, Chongqing, China
| | - Wei Tan
- Department of Gastroenterology, Chongqing General Hospital, Chongqing, China
| | - Zhengying Zhang
- Department of Health Management Center, Chongqing General Hospital, 5 Xingguang Road, Xingguang Street, Yubei District, Chongqing, 400000, ChongQing Province, China.
| | - Kang Li
- Department of Radiology, Chongqing General Hospital, 118 Xingguang Street, Yubei District, Chongqing, 400000, ChongQing Province, China.
| |
Collapse
|
3
|
Lee T, Yoon JH, Park JY, Lee J, Choi JW, Ahn C, Lee JM. Deep learning-based iodine contrast-augmenting algorithm for low-contrast-dose liver CT to assess hypovascular hepatic metastasis. Abdom Radiol (NY) 2023; 48:3430-3440. [PMID: 37704805 DOI: 10.1007/s00261-023-04039-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 08/23/2023] [Accepted: 08/24/2023] [Indexed: 09/15/2023]
Abstract
PURPOSE To investigate the image quality and diagnostic performance of low-contrast-dose liver CT using a deep learning-based iodine contrast-augmenting algorithm (DLICA) for hypovascular hepatic metastases. METHODS This retrospective study included 128 patients who underwent contrast-enhanced dual-energy CT for hepatic metastasis surveillance between July 2019 and June 2022 using a 30% reduced iodine contrast dose in the portal phase. Three image types were reconstructed: 50-keV virtual monoenergetic images (50-keV VMI); linearly blended images simulating 120-kVp images (120-kVp); and post-processed 120-kVp images using DLICA (DLICA 120-kVp). Three reviewers evaluated lesion conspicuity, image contrast, and subjective image noise. We also measured image noise, contrast-to-noise ratios (CNRs), and signal-to-noise ratios (SNRs). The diagnostic performance for hepatic metastases was evaluated using a jackknife alternative free-response receiver operating characteristic method with the consensus of two independent radiologists as the reference standard. RESULTS DLICA 120-kVp demonstrated significantly higher CNR of lesions to liver (5.7 ± 3.1 vs. 3.8 ± 2.1 vs. 3.8 ± 2.1) and higher SNR compared with 50-keV VMI and 120-kVp (p < 0.001 for all). DLICA 120-kVp had significantly lower image noise than 50-kVp VMI for all regions (p < 0.001 for all). DLICA 120-kVp also exhibited superior lesion conspicuity (4.0 [3.3-4.3] vs. 3.7 [3.0-4.0] vs. 3.7 [3.0-4.0]), higher image contrast, and lower subjective image noise compared with 50-keV VMI and 120-kVp (p < 0.001 for all). Although there was no significant difference in the figure of merit for lesion diagnosis among the three methods (p = 0.11), DLICA 120-kVp had a significantly higher figure of merit for lesions with a diameter < 20 mm than 50-keV VMI (0.677 vs. 0.648, p = 0.007). On a per-lesion basis, DLICA 120-kVp also demonstrated higher sensitivity than the 50-keV VMI (81.2% vs. 72.9%, p < 0.001). The specificities per lesion were not significantly different among the three algorithms (p = 0.15). CONCLUSION DLICA at 120-kVp provided superior lesion conspicuity and image quality and similar diagnostic performance for hypovascular hepatic metastases compared with 50-keV VMI.
Collapse
Affiliation(s)
- Taehee Lee
- Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea
| | - Jeong Hee Yoon
- Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea
- Department of Radiology, Seoul National University College of Medicine, 101, Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
| | - Jin Young Park
- Department of Radiology, Busan Paik Hospital, Inje University College of Medicine, Busan, Republic of Korea
| | - Jihyuk Lee
- Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea
| | - Jae Won Choi
- Department of Radiology, Seoul National University College of Medicine, 101, Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea
- Department of Radiology, Armed Forces Yangju Hospital, Yangju, Republic of Korea
| | - Chulkyun Ahn
- Department of Transdisciplinary Studies, Program in Biomedical Radiation Sciences, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea
- ClariPi Research, Seoul, Republic of Korea
| | - Jeong Min Lee
- Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea.
- Department of Radiology, Seoul National University College of Medicine, 101, Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea.
| |
Collapse
|
4
|
Agostini A, Borgheresi A, Mariotti F, Ottaviani L, Carotti M, Valenti M, Giovagnoni A. New Frontiers in Oncological Imaging With Computed Tomography: From Morphology to Function. Semin Ultrasound CT MR 2023; 44:214-227. [PMID: 37245886 DOI: 10.1053/j.sult.2023.03.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
Abstract
The latest evolutions in Computed Tomography (CT) technology have several applications in oncological imaging. The innovations in hardware and software allow for the optimization of the oncological protocol. Low-kV acquisitions are possible thanks to the new powerful tubes. Iterative reconstruction algorithms and artificial intelligence are helpful for the management of image noise during image reconstruction. Functional information is provided by spectral CT (dual-energy and photon counting CT) and perfusion CT.
Collapse
Affiliation(s)
- Andrea Agostini
- Department of Clinical, Special and Dental Sciences. University Politecnica delle Marche, Ancona, Italy; Department of Radiological Sciences, Division of Clinical Radiology, University Hospital "Azienda Ospedaliero Universitaria delle Marche", Ancona, Italy.
| | - Alessandra Borgheresi
- Department of Clinical, Special and Dental Sciences. University Politecnica delle Marche, Ancona, Italy; Department of Radiological Sciences, Division of Clinical Radiology, University Hospital "Azienda Ospedaliero Universitaria delle Marche", Ancona, Italy
| | - Francesco Mariotti
- Department of Radiological Sciences, Division of Medical Physics, University Hospital "Azienda Ospedaliero Universitaria delle Marche", Ancona, Italy
| | - Letizia Ottaviani
- Department of Radiological Sciences, Division of Clinical Radiology, University Hospital "Azienda Ospedaliero Universitaria delle Marche", Ancona, Italy
| | - Marina Carotti
- Department of Clinical, Special and Dental Sciences. University Politecnica delle Marche, Ancona, Italy; Department of Radiological Sciences, Division of Clinical Radiology, University Hospital "Azienda Ospedaliero Universitaria delle Marche", Ancona, Italy
| | - Marco Valenti
- Department of Radiological Sciences, Division of Medical Physics, University Hospital "Azienda Ospedaliero Universitaria delle Marche", Ancona, Italy
| | - Andrea Giovagnoni
- Department of Clinical, Special and Dental Sciences. University Politecnica delle Marche, Ancona, Italy; Department of Radiological Sciences, Division of Clinical Radiology, University Hospital "Azienda Ospedaliero Universitaria delle Marche", Ancona, Italy
| |
Collapse
|
5
|
Seah HM, Choi HC, Bajic N, Oakden‐Rayner L, Gormly KL. Assessment of a single‐pass venous phase
CT
chest, abdomen and pelvis and dual‐energy
CT
in general oncology outpatients. J Med Imaging Radiat Oncol 2022. [DOI: 10.1111/1754-9485.13490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Accepted: 10/24/2022] [Indexed: 11/22/2022]
Affiliation(s)
- Huey Ming Seah
- South Australia Medical Imaging Adelaide South Australia Australia
| | - Hau Cher Choi
- South Australia Medical Imaging Adelaide South Australia Australia
| | - Nicholas Bajic
- South Australia Medical Imaging Adelaide South Australia Australia
- Jones Radiology Adelaide South Australia Australia
| | - Lauren Oakden‐Rayner
- South Australia Medical Imaging Adelaide South Australia Australia
- Jones Radiology Adelaide South Australia Australia
- Australian Institute for Machine Learning University of Adelaide Adelaide South Australia Australia
- The University of Adelaide Adelaide South Australia Australia
| | - Kirsten L Gormly
- Jones Radiology Adelaide South Australia Australia
- The University of Adelaide Adelaide South Australia Australia
| |
Collapse
|
6
|
Lee T, Lee JM, Yoon JH, Joo I, Bae JS, Yoo J, Kim JH, Ahn C, Kim JH. Deep learning-based image reconstruction of 40-keV virtual monoenergetic images of dual-energy CT for the assessment of hypoenhancing hepatic metastasis. Eur Radiol 2022; 32:6407-6417. [PMID: 35380228 DOI: 10.1007/s00330-022-08728-0] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 02/19/2022] [Accepted: 03/10/2022] [Indexed: 12/18/2022]
Abstract
OBJECTIVES To evaluate the diagnostic value of deep learning model (DLM) reconstructed dual-energy CT (DECT) low-keV virtual monoenergetic imaging (VMI) for assessing hypoenhancing hepatic metastases. METHODS This retrospective study included 131 patients who underwent contrast-enhanced DECT (80-kVp and 150-kVp with a tin filter) in the portal venous phase for hepatic metastasis surveillance. Linearly blended images simulating 100-kVp images (100-kVp), standard 40-keV VMI images (40-keV VMI), and post-processed 40-keV VMI using a vendor-agnostic DLM (i.e., DLM 40-keV VMI) were reconstructed. Lesion conspicuity and diagnostic acceptability were assessed by three independent reviewers and compared using the Wilcoxon signed-rank test. The contrast-to-noise ratios (CNRs) were also measured placing ROIs in metastatic lesions and liver parenchyma. The detection performance of hepatic metastases was assessed by using a jackknife alternative free-response ROC method. The consensus by two independent radiologists was used as the reference standard. RESULTS DLM 40-keV VMI, compared to 40-keV VMI and 100-kVp, showed a higher lesion-to-liver CNR (8.25 ± 3.23 vs. 6.05 ± 2.38 vs. 5.99 ± 2.00), better lesion conspicuity (4.3 (4.0-4.7) vs. 3.7 (3.7-4.0) vs. 3.7 (3.3-4.0)), and better diagnostic acceptability (4.3 (4.0-4.3) vs. 3.0 (2.7-3.3) vs. 4.0 (4.0-4.3)) (p < 0.001 for all). For lesion detection (246 hepatic metastases in 68 patients), the figure of merit was significantly higher with DLM 40-keV VMI than with 40-keV VMI (0.852 vs. 0.822, p = 0.012), whereas no significant difference existed between DLM 40-keV VMI and 100-kVp (0.852 vs. 0.842, p = 0.31). CONCLUSIONS DLM 40-keV VMI provided better image quality and comparable diagnostic performance for detecting hypoenhancing hepatic metastases compared to linearly blended images. KEY POINTS • DLM 40-keV VMI provides a superior image quality compared with 40-keV or 100-kVp for assessing hypoenhancing hepatic metastasis. • DLM 40-keV VMI has the highest CNR and lesion conspicuity score for hypoenhancing hepatic metastasis due to noise reduction and structural preservation. • DLM 40-keV VMI provides higher lesion detectability than standard 40-keV VMI (p = 0.012).
Collapse
Affiliation(s)
- Taehee Lee
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea
| | - Jeong Min Lee
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea. .,Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, Korea. .,Institute of Radiation Medicine, Seoul National University Medical Research Center, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea.
| | - Jeong Hee Yoon
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea.,Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, Korea
| | - Ijin Joo
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea.,Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, Korea
| | - Jae Seok Bae
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea
| | - Jeongin Yoo
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea
| | - Jae Hyun Kim
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea
| | - Chulkyun Ahn
- Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Korea
| | - Jong Hyo Kim
- Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, Korea.,Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Korea.,Center for Medical-IT Convergence Technology Research, Advanced Institutes of Convergence Technology, Suwon, 16229, Korea
| |
Collapse
|
7
|
Narappulan N, Arunachalam VK, Alavandar E, Selvaraja S, Renganathan R, Cherian M. Evaluation of Hypervascular Focal Liver Lesions Utilizing Virtual Monoenergetic Images from Third-Generation Dual-Source Dual-Energy Computed Tomography. JOURNAL OF GASTROINTESTINAL AND ABDOMINAL RADIOLOGY 2022. [DOI: 10.1055/s-0042-1742677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
Abstract
Objectives The purpose of our study was to evaluate the virtual monochromatic imaging in detecting hypervascular focal liver lesions in the late arterial phase with third-generation dual-source dual-energy computed tomography and to assess its image quality.
Materials and Methods In our study, 80 patients were included. Contrast-enhanced images in the late arterial phase (in the dual-energy mode) were acquired and were post-processed in Syngo, via workstation, using Monoenergetic + software. Five sets of images, one polychromatic energy image (corresponding to 120 kVp single-energy image) and four virtual monoenergetic image (VMI) sets at 40, 50, 60, and 70 keV levels, were generated. All these images were analyzed both objectively and subjectively. The attenuation values were measured, and the contrast-to-noise ratio (CNR) of liver and tumor were measured and compared objectively in each dataset. Image noise, image contrast, and diagnostic confidence for liver lesion detection were analyzed subjectively using a five-point scale system. Statistical analysis was performed using Kolmogorov–Smirnov, analysis of variance, and Kruskal–Wallis tests.
Results Among the VMI, maximum image noise was observed in the 40 keV image, with a gradual reduction in the image noise being noted with an increase in the VMI energy. The CNR of the hepatic parenchyma and the tumor gradually increased with a reduction in VMI energy from 70 to 40 keV. On subjective analysis, image contrast and image noise were observed to be more in low VMI datasets. In lesion detection, diagnostic confidence with an excellent confidence level was observed with a decrease in VMI energy.
Conclusion VMI datasets of 40 to 70 keV from third-generation dual-source DECT provide superior diagnostic accuracy for detecting hypervascular liver lesions. Considering the image noise and lesion detection rate among the VMI datasets, 60 keV VMI is the most helpful dataset for increased liver lesion detection with good image quality.
Collapse
Affiliation(s)
- Niyas Narappulan
- Department of Radiology, Kovai Medical Center and Hospital, Coimbatore, India
| | | | | | - Swathigha Selvaraja
- Department of Radiology, Kovai Medical Center and Hospital, Coimbatore, India
| | - Rupa Renganathan
- Department of Radiology, Kovai Medical Center and Hospital, Coimbatore, India
| | - Mathew Cherian
- Department of Radiology, Kovai Medical Center and Hospital, Coimbatore, India
| |
Collapse
|
8
|
Lin L, Han L, Jia S, Zhang T, Liu Z, Fan J. Evaluating image quality and optimal parameters for non-linear blending dual-energy computed tomography images of hepatic portal veins by blending-property-map. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2022; 30:835-846. [PMID: 35599529 DOI: 10.3233/xst-221182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
BACKGROUND Blending technology is usually used to improve quality of dual-energy computed (DECT) images. OBJECTIVES To evaluate the blended DECT image qualities by employing the Blending-Property-Map (BP-Map) and elucidating the optimal parameters with the highest signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). METHODS Sixty pairs of 80 kV and 140 kV CT images are blended non-linearly by four methods. Protocol A uses the fixed values of blending width (BW) and blending center (BC); Protocol B uses the values of BW = (CThepatic portal vein - CThepatic parenchymal) / 2 and BC = (CThepatic portal vein + CThepatic parenchymal) / 2; Protocol C uses a BW ranging from 10 to 100 HU at an interval of 10 HU and BC = (CThepatic portal vein + CThepatic parenchymal) / 2; Protocol D uses the BP-Map that covers all possible values of BW and BC. RESULTS When using CT value of adipose tissue as noise, the calculated SNR and CNR of optimal blending width and blending center were 123.22±41.73 and 9.00±3.52, respectively, by the BP-Map in the protocol D. By employing the CT value of back muscle as noise, the SNR and CNR of the best-blended images were 75.90±14.52 and 6.39±2.37, respectively. The subjective score of protocol D was 4.88±0.12. CONCLUSIONS Compared to traditional blending methods, the BP-Map technique can determine the optimal blending parameter and provide the best-blended images with the highest SNR and CNR.
Collapse
Affiliation(s)
- Liying Lin
- First Central Clinical College, Tianjin Medical University, Tianjin, China
| | - Li Han
- School of Medical Imaging, Tianjin Medical University, Tianjin, China
- Department of Radiology, Tianjin Medical University General Hospital, Tianjin, China
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Shaowei Jia
- Department of Biomedical Engineering, College of Engineering, Peking University, Beijing, China
| | - Tianyou Zhang
- Department of Radiology, Chinese Academy of Medical Sciences Institute of Hematology and Blood Diseases Hospital, Tianjin, China
| | - Zefeng Liu
- Department of Radiology, Tianjin Medical University General Hospital, Tianjin, China
| | - Jie Fan
- School of Linguistics, Hebei University of Technology, Tianjin, China
| |
Collapse
|
9
|
Wang T, Han Y, Lin L, Yu C, Lv R, Han L. Image quality enhancement of CT hepatic portal venography using dual energy blending with computer determined parameters. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2022; 30:307-317. [PMID: 35001902 DOI: 10.3233/xst-210967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
BACKGROUND Previous studies have shown that using some post-processing methods, such as nonlinear-blending and linear blending techniques, has potential to improve dual-energy computed (DECT) image quality. OBJECTIVE To improve DECT image quality of hepatic portal venography (CTPV) using a new non-linear blending method with computer-determined parameters, and to compare the results to additional linear and non-linear blending techniques. METHODS DECT images of 60 patients who were clinically diagnosed with liver cirrhosis were selected and studied. Dual-energy scanning (80 kVp and Sn140 kVp) of CTPV was utilized in the portal venous phase through a dual-source CT scanner. For image processing, four protocols were utilized including linear blending with a weighing factor of 0.3 (protocol A) and 1.0 (protocol B), non-linear blending with fixed blending width of 200 HU and set blending center of 150HU (protocol C), and computer-based blending (protocol D). Several image quality indicators, including signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and contrast of hepatic portal vein and hepatic parenchyma, were evaluated using the paired-sample t-test. A 5-grade scale scoring system was also utilized for subjective analysis. RESULTS SNR of protocols A-D were 9.1±2.1, 12.1±3.0, 11.6±2.8 and 14.4±3.2, respectively. CNR of protocols A-D were 4.6±1.3, 8.0±2.3, 7.0±2.0 and 9.8±2.4, respectively. The contrast of protocols A-D were 37.7±11.6, 91.9±21.0, 66.2±19.0 and 107.7±21.3, respectively. The differences between protocol D and other three protocols were significant (P < 0.01). In subjective evaluation, the modes of protocols A, B, C, and D were rated poor, good, generally acceptable, and excellent, respectively. CONCLUSION The non-linear blending technique of protocol D with computer-determined blending parameters can help improve imaging quality of CTPV and contribute to a diagnosis of liver disease.
Collapse
Affiliation(s)
- Tao Wang
- Department of Radiology, Tianjin Third Central Hospital, Tianjin, China
- Tianjin Institute of Hepatobiliary Disease, Tianjin, China
- Tianjin Key Laboratory of Artificial Cell, Tianjin, China
- Artificial Cell Engineering Technology Research Center of Public Health Ministry, Tianjin, China
| | - Yuxin Han
- Department of Radiology, Tianjin Third Central Hospital, Tianjin, China
- Tianjin Institute of Hepatobiliary Disease, Tianjin, China
- Tianjin Key Laboratory of Artificial Cell, Tianjin, China
- Artificial Cell Engineering Technology Research Center of Public Health Ministry, Tianjin, China
| | - Liying Lin
- First Central Clinical College, Tianjin Medical University, Tianjin, China
| | - Changlu Yu
- Department of Radiology, Tianjin Third Central Hospital, Tianjin, China
- Tianjin Institute of Hepatobiliary Disease, Tianjin, China
- Tianjin Key Laboratory of Artificial Cell, Tianjin, China
- Artificial Cell Engineering Technology Research Center of Public Health Ministry, Tianjin, China
| | - Rong Lv
- Department of Radiology, Tianjin Third Central Hospital, Tianjin, China
- Tianjin Institute of Hepatobiliary Disease, Tianjin, China
- Tianjin Key Laboratory of Artificial Cell, Tianjin, China
- Artificial Cell Engineering Technology Research Center of Public Health Ministry, Tianjin, China
| | - Li Han
- School of Medical Imaging, Tianjin Medical University, Tianjin, China
- Department of Biomedical Engineering, College of Engineering, Peking University, Beijing, China
| |
Collapse
|
10
|
Euler A, Zadory M, Breiding PS, Sartoretti T, Ghafoor S, Froehlich JM, Donati OF. Realistic Kidney Tissue Surrogates for Multienergy Computed Tomography-Feasibility and Estimation of Energy-Dependent Attenuation Thresholds for Renal Lesion Enhancement in Low-kV and Virtual Monoenergetic Imaging. Invest Radiol 2021; 56:791-798. [PMID: 33899757 DOI: 10.1097/rli.0000000000000790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE The aims of this study were to assess if kidney tissue surrogates (KTSs) are superior to distilled water-iodine solutions in the emulation of energy-dependent computed tomography (CT) attenuation characteristics of renal parenchyma and to estimate attenuation thresholds for definite lesion enhancement for low-kV single-energy and low-keV dual-energy virtual monoenergetic imaging. METHODS A water-filled phantom (diameter, 30 cm) with multiple vials was imaged on a dual-source dual-energy CT (DS-DE) and a single-source split-filter dual-energy CT (SF-DE), both in single-energy mode at 80, 100, 120, 140 kVp and in dual-energy mode at 80/Sn150, 90/Sn150, and 100/Sn150 kVp for DS-DE and AuSn120 kVp for SF-DE. Single-energy images, linear-blended dual-energy images, and virtual monoenergetic imaging at energy levels from 40 to 190 keV were reconstructed. First, attenuation characteristics of KTS in solid and liquid consistencies were compared. Second, solid KTSs were developed to match the CT attenuation of unenhanced renal parenchyma at 120 kVp as retrospectively measured in 100 patients. Third, CT attenuation of KTS-iodine and water-iodine solutions at 8 different iodine concentrations (0-10 mg I/mL) were compared as a function of tube voltage and of keV level using multiple linear regression models. Energy-dependent attenuation thresholds for definite lesion enhancement were calculated. RESULTS Unenhanced renal parenchyma at 120 kVp measured on average 30 HU on both scanners in the patient cohort. Solid KTS with a water content of 80% emulated the attenuation of unenhanced renal parenchyma (30 HU) more accurately compared with water-iodine solutions (0 HU). Attenuation difference between KTS-iodine and water-iodine solutions converged with increasing iodine concentration and decreasing x-ray energy due to beam-hardening effects. A slight attenuation difference of approximately 2 HU was found between the 2 CT scanners. Attenuation thresholds for definite lesion enhancement were dependent on tube voltage and keV level and ranged from 16.6 to 33.2 HU and 3.2 to 68.3 HU for single-energy and dual-energy CT scan modes for DS-DE and from 16.1 to 34.3 HU and 3.3 to 92.2 HU for SF-DE. CONCLUSIONS Kidney tissue surrogates more accurately emulate the energy-dependent CT attenuation characteristics of renal parenchyma for multienergy CT compared with conventional water-iodine approaches. Energy-dependent thresholds for definite lesion enhancement could facilitate lesion characterization when imaging at different energies than the traditional 120 kVp.
Collapse
Affiliation(s)
- André Euler
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich
| | | | - Philipe Sebastian Breiding
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich
| | | | - Soleen Ghafoor
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich
| | | | - Olivio Fabrizio Donati
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich
| |
Collapse
|
11
|
Jirapatnakul A, Yip R, Branch AD, Lewis S, Crane M, Yankelevitz DF, Henschke CI. Dose-response relationship between World Trade Center dust exposure and hepatic steatosis. Am J Ind Med 2021; 64:837-844. [PMID: 34328231 DOI: 10.1002/ajim.23269] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 05/04/2021] [Accepted: 05/17/2021] [Indexed: 12/19/2022]
Abstract
BACKGROUND The World Trade Center (WTC) attack exposed thousands of workers to toxic chemicals that have been linked to liver diseases and cancers. This study examined the relationship between the intensity of WTC dust exposure and the risk of hepatic steatosis in the WTC General Responders Cohort (GRC). METHODS All low-dose computed tomography (CT) scans of the chest performed on the WTC GRC between September 11, 2001 and December 31, 2018, collected as part of the World Trade Center Health Program, were reviewed. WTC dust exposure was categorized into five groups based on WTC arrival time. CT liver density was estimated using an automated algorithm, statistics-based liver density estimation from imaging. The relationship between the intensity of WTC dust exposure and the risk of hepatic steatosis was examined using univariate and multivariable regression analyses. RESULTS Of the 1788 WTC responders, 258 (14.4%) had liver attenuation less than 40 Hounsfield units (HU < 40) on their earliest CT. Median time after September 11, 2001 and the earliest available CT was 11.3 years (interquartile range: 8.0-14.9 years). Prevalence of liver attenuation less than 40 HU was 17.0% for arrivals on September 11, 2001, 16.0% for arrivals on (September 12, 2001 or September 13, 2001), 10.9% for arrivals on September 14-30, 2001, and 9.0% for arrivals on January 10, 2001 or later (p = 0.0015). A statistically significant trend of increasing liver steatosis was observed with earlier arrival times (p < 0.0001). WTC arrival time remained a significant independent factor for decreased liver attenuation after controlling for other covariates. CONCLUSIONS Early arrival at the WTC site was significantly associated with increasing hepatic steatosis.
Collapse
Affiliation(s)
- Artit Jirapatnakul
- Department of Radiology Icahn School of Medicine at Mount Sinai New York New York USA
| | - Rowena Yip
- Department of Radiology Icahn School of Medicine at Mount Sinai New York New York USA
| | - Andrea D. Branch
- Division of Liver Diseases, Department of Medicine Icahn School of Medicine at Mount Sinai New York New York USA
| | - Sara Lewis
- Department of Radiology Icahn School of Medicine at Mount Sinai New York New York USA
| | - Michael Crane
- Department of Environmental Medicine and Public Health Icahn School of Medicine at Mount Sinai New York New York USA
| | - David F. Yankelevitz
- Department of Radiology Icahn School of Medicine at Mount Sinai New York New York USA
| | - Claudia I. Henschke
- Department of Radiology Icahn School of Medicine at Mount Sinai New York New York USA
| |
Collapse
|
12
|
Laroia ST, Yadav K, Kumar S, Rastogi A, Kumar G, Sarin SK. Material decomposition using iodine quantification on spectral CT for characterising nodules in the cirrhotic liver: a retrospective study. Eur Radiol Exp 2021; 5:22. [PMID: 34046753 PMCID: PMC8160046 DOI: 10.1186/s41747-021-00220-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Accepted: 04/07/2021] [Indexed: 12/15/2022] Open
Abstract
Background There is limited scientific evidence on the potential of spectral computed tomography (SCT) for differentiation of nodules in the cirrhotic liver. We aimed to assess SCT-generated material density (MD) parameters for nodule characterisation in cirrhosis. Methods Dynamic dual-energy SCT scans of cirrhotic patients performed over 3 years were retrospectively reviewed. They were classified as hepatocellular carcinoma (HCC), regenerative or indeterminate, according to the European Association for the Study of the Liver criteria. MD maps were generated to calculate the area under the curve (AUC) and cutoff values to discriminate these nodules in the hepatic arterial phase (HAP) and portal venous phase (PVP). MD maps included iodine concentration density (ICD) of the liver and nodule, lesion-to-normal liver ICD ratio (LNR) and difference in nodule ICD between HAP and PVP. Results Three hundred thirty nodules belonging to 300 patients (age 53.0 ± 12.7 years, mean ± standard deviation) were analysed at SCT (size 2.3 ± 0.8 cm, mean ± SD). One hundred thirty-three (40.3%) nodules were classified as HCC, 147 (44.5%) as regenerative and 50 (15.2%) as indeterminate. On histopathology, 136 (41.2%) nodules were classified as HCC, 183 (55.5%) as regenerative and 11 (3.3%) as dysplastic. All MD parameters on HAP and the nodule difference in ICD could discriminate pathologically proven HCC or potentially malignant nodules from regenerative nodules (p < 0.001). The AUC was 82.4% with a cutoff > 15.5 mg/mL for nodule ICD, 81.3% > 1.8 for LNR-HAP and 81.3% for difference in ICD > 3.5 mg/mL. Conclusion SCT-generated MD parameters are viable diagnostic tools for differentiating malignant or potentially malignant from benign nodules in the cirrhotic liver. Supplementary Information The online version contains supplementary material available at 10.1186/s41747-021-00220-6.
Collapse
Affiliation(s)
- Shalini Thapar Laroia
- Department of Radiology, Institute of Liver and Biliary Sciences, Sector D-1, Vasant Kunj, New Delhi, 110070, India.
| | - Komal Yadav
- Department of Radiology, Institute of Liver and Biliary Sciences, Sector D-1, Vasant Kunj, New Delhi, 110070, India
| | - Senthil Kumar
- Department of HPB Surgery and Liver Transplantation, Institute of Liver & Biliary Sciences, Sector D-1, Vasant Kunj, New Delhi, 110070, India
| | - Archana Rastogi
- Department of Clinical and Hepato-pathology, Institute of Liver and Biliary Sciences, Sector D-1, Vasant Kunj, New Delhi, 110070, India
| | - Guresh Kumar
- Department of Biostatistics and Research, Institute of Liver & Biliary Sciences, Sector D-1, Vasant Kunj, New Delhi, 110070, India
| | - Shiv Kumar Sarin
- Department of Hepatology, Institute of Liver & Biliary Sciences, Sector D-1, Vasant Kunj, New Delhi, 110 070, India
| |
Collapse
|
13
|
de Jong DJ, Veldhuis WB, Wessels FJ, de Vos B, Moeskops P, Kok M. Towards Personalised Contrast Injection: Artificial-Intelligence-Derived Body Composition and Liver Enhancement in Computed Tomography. J Pers Med 2021; 11:jpm11030159. [PMID: 33668286 PMCID: PMC7996171 DOI: 10.3390/jpm11030159] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2020] [Revised: 02/15/2021] [Accepted: 02/18/2021] [Indexed: 12/11/2022] Open
Abstract
In contrast-enhanced computed tomography, total body weight adapted contrast injection protocols have proven successful in achieving a homogeneous enhancement of vascular structures and liver parenchyma. However, because solid organs have greater perfusion than adipose tissue, the lean body weight (fat-free mass) rather than the total body weight is theorised to cause even more homogeneous enhancement. We included 102 consecutive patients who underwent a multiphase abdominal computed tomography between March 2016 and October 2019. Patients received contrast media (300 mgI/mL) according to bodyweight categories. Using regions of interest, we measured the Hounsfield unit (HU) increase in liver attenuation from unenhanced to contrast-enhanced computed tomography. Furthermore, subjective image quality was graded using a four-point Likert scale. An artificial intelligence algorithm automatically segmented and determined the body compositions and calculated the percentages of lean body weight. The hepatic enhancements were adjusted for iodine dose and iodine dose per total body weight, as well as percentage lean body weight. The associations between enhancement and total body weight, body mass index, and lean body weight were analysed using linear regression. Patients had a median age of 68 years (IQR: 58–74), a total body weight of 81 kg (IQR: 73–90), a body mass index of 26 kg/m2 (SD: ±4.2), and a lean body weight percentage of 50% (IQR: 36–55). Mean liver enhancements in the portal venous phase were 61 ± 12 HU (≤70 kg), 53 ± 10 HU (70–90 kg), and 53 ± 7 HU (≥90 kg). The majority (93%) of scans were rated as good or excellent. Regression analysis showed significant correlations between liver enhancement corrected for injected total iodine and total body weight (r = 0.53; p < 0.001) and between liver enhancement corrected for lean body weight and the percentage of lean body weight (r = 0.73; p < 0.001). Most benefits from personalising iodine injection using %LBW additive to total body weight would be achieved in patients under 90 kg. Liver enhancement is more strongly associated with the percentage of lean body weight than with the total body weight or body mass index. The observed variation in liver enhancement might be reduced by a personalised injection based on the artificial-intelligence-determined percentage of lean body weight.
Collapse
Affiliation(s)
- Daan J. de Jong
- Department of Radiology, University Medical Center Utrecht, Heilberglaan 100, 3584 CX Utrecht, The Netherlands; (D.J.d.J.); (W.B.V.); (F.J.W.)
| | - Wouter B. Veldhuis
- Department of Radiology, University Medical Center Utrecht, Heilberglaan 100, 3584 CX Utrecht, The Netherlands; (D.J.d.J.); (W.B.V.); (F.J.W.)
| | - Frank J. Wessels
- Department of Radiology, University Medical Center Utrecht, Heilberglaan 100, 3584 CX Utrecht, The Netherlands; (D.J.d.J.); (W.B.V.); (F.J.W.)
| | - Bob de Vos
- Quantib-U, Padualaan 8, 3584 CH Utrecht, The Netherlands; (B.d.V.); (P.M.)
| | - Pim Moeskops
- Quantib-U, Padualaan 8, 3584 CH Utrecht, The Netherlands; (B.d.V.); (P.M.)
| | - Madeleine Kok
- Department of Radiology, University Medical Center Utrecht, Heilberglaan 100, 3584 CX Utrecht, The Netherlands; (D.J.d.J.); (W.B.V.); (F.J.W.)
- Correspondence: ; Tel.: +31-88-75555-55
| |
Collapse
|
14
|
Jiang X, Yang X, Hintenlang DE, White RD. Effects of Patient Size and Radiation Dose on Iodine Quantification in Dual-Source Dual-Energy CT. Acad Radiol 2021; 28:96-105. [PMID: 32094030 DOI: 10.1016/j.acra.2019.12.027] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2019] [Revised: 11/27/2019] [Accepted: 12/17/2019] [Indexed: 12/20/2022]
Abstract
RATIONALE AND OBJECTIVES The purpose of this study was to investigate the potential effects of patient size and radiation dose on the accuracy of iodine quantification using dual-source dual-energy computed tomography (CT). MATERIALS AND METHODS Three phantoms representing different patient sizes were constructed, containing iodine inserts with concentrations from 0 to 20 mg/ml. Dual-energy CT scans were performed at six dose levels from 2 to 30 mGy. Iodine concentrations were measured using a three-material-decomposition algorithm and their accuracy was assessed. RESULTS In a small phantom, iodine quantification was accurate and consistent at all dose levels. In a medium phantom, minor underestimations were observed, and the results were consistent except at low dose. In the large phantom, more significant underestimation of iodine concentration was observed at higher doses (≥15 mGy), which was attributed to the beam-hardening effect. At lower doses, increasing upward bias was observed in the CT number, leading to significant overestimations of both iodine concentration and fat fraction, which was attributed to the photon-starvation effect. The severity of the latter effect was determined by mA instead of mAs, suggesting that the electronic noise, rather than the quantum noise, was responsible for the bias. Using higher kVp for the low-energy tube was found to alleviate these effects. CONCLUSION Reliable iodine quantification can be achieved using dual-source CT, but the result can be affected by patient size and dose rate. In large patients, biases may occur due to the beam-hardening and the photon-starvation effects, in which case higher dose rate and higher kVp are recommended to minimize these effects.
Collapse
Affiliation(s)
- Xia Jiang
- Department of Radiology, Ohio State University College of Medicine, 395 W 12th Ave, Columbus, OH 43210.
| | - Xiangyu Yang
- Department of Radiology, Ohio State University College of Medicine, 395 W 12th Ave, Columbus, OH 43210
| | - David E Hintenlang
- Department of Radiology, Ohio State University College of Medicine, 395 W 12th Ave, Columbus, OH 43210
| | - Richard D White
- Department of Radiology, Ohio State University College of Medicine, 395 W 12th Ave, Columbus, OH 43210
| |
Collapse
|
15
|
Usefulness of dual-energy computed tomography for oral cancer image. Oral Radiol 2021; 37:585-590. [PMID: 33386526 DOI: 10.1007/s11282-020-00494-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Accepted: 11/10/2020] [Indexed: 10/22/2022]
Abstract
OBJECTIVES We aimed to compare dual-energy computed tomography (DECT) virtual monochromatic imaging (VMI) and iodine density imaging (IDI) of oral cancers in terms of visual scoring and tumour volume estimation. MATERIALS AND METHODS Nine patients diagnosed with oral cancer who underwent DECT VMI and IDI were enrolled. One radiation oncologist, one head and neck surgeon and nine oral surgeons evaluated image clarity and quality in each patient in terms of metal artefacts due to dental prosthesis, internal tumour structure, tumour-organ boundary and total quality of images for diagnosis. Tumour volume was estimated using VMI, IDI and magnetic resonance imaging (MRI). RESULTS The mean score for image artefact was significantly higher for IDI than for VMI in three observers, the mean score for internal structure was significantly higher for IDI than for VMI in five, the mean score for tumour-organ boundary was significantly higher for IDI than for VMI in two and the mean score for total quality of images for diagnosis was significantly higher for IDI than for VMI in five. Standard deviation of estimated tumour volume was not significantly different between VMI and IDI, but that of MRI was significantly lowest in three images. CONCLUSIONS In DECT for oral cancer, IDI has a visual image superior to VMI; thus, we recommend the use of IDI. TRIAL REGISTRATION Clinical trial number: UMIN000038994.
Collapse
|
16
|
DiMaso LD, Miller JR, Lawless MJ, Bassetti MF, DeWerd LA, Huang J. Investigating split-filter dual-energy CT for improving liver tumor visibility for radiation therapy. J Appl Clin Med Phys 2020; 21:249-255. [PMID: 32410336 PMCID: PMC7484851 DOI: 10.1002/acm2.12904] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2019] [Revised: 01/20/2020] [Accepted: 04/16/2020] [Indexed: 11/17/2022] Open
Abstract
Purpose Accurate liver tumor delineation is crucial for radiation therapy, but liver tumor volumes are difficult to visualize with conventional single‐energy CT. This work investigates the use of split‐filter dual‐energy CT (DECT) for liver tumor visibility by quantifying contrast and contrast‐to‐noise ratio (CNR). Methods Split‐filter DECT contrast‐enhanced scans of 20 liver tumors including cholangiocarcinomas, hepatocellular carcinomas, and liver metastases were acquired. Analysis was performed on the arterial and venous phases of mixed 120 kVp‐equivalent images and VMIs at 57 keV and 40 keV gross target volume (GTV) contrast and CNR were calculated. Results For the arterial phase, liver GTV contrast was 12.1 ± 10.0 HU and 43.1 ± 32.3 HU (P < 0.001) for the mixed images and 40 keV VMIs. Image noise increased on average by 116% for the 40 keV VMIs compared to the mixed images. The average CNR did not change significantly (1.6 ± 1.5, 1.7 ± 1.4, 2.4 ± 1.7 for the mixed, 57 keV and 40 keV VMIs (P > 0.141)). For individual cases, however, CNR increases of up to 607% were measured for the 40 keV VMIs compared to the mixed image. Venous phase 40 keV VMIs demonstrated an average increase of 35.4 HU in GTV contrast and 121% increase in image noise. Average CNR values were also not statistically different, but for individual cases CNR increases of up to 554% were measured for the 40 keV VMIs compared to the mixed image. Conclusions Liver tumor contrast was significantly improved using split‐filter DECT 40 keV VMIs compared to mixed images. On average, there was no statistical difference in CNR between the mixed images and VMIs, but for individual cases, CNR was greatly increased for the 57 keV and 40 keV VMIs. Therefore, although not universally successful for our patient cohort, split‐filter DECT VMIs may provide substantial gains in tumor visibility of certain liver cases for radiation therapy treatment planning.
Collapse
Affiliation(s)
- Lianna D. DiMaso
- Department of Medical PhysicsUniversity of Wisconsin‐MadisonMadisonWIUSA
| | - Jessica R. Miller
- Department of Human OncologyUniversity of Wisconsin‐MadisonMadisonWIUSA
| | | | | | - Larry A. DeWerd
- Department of Medical PhysicsUniversity of Wisconsin‐MadisonMadisonWIUSA
| | - Jessie Huang
- Department of Human OncologyUniversity of Wisconsin‐MadisonMadisonWIUSA
| |
Collapse
|
17
|
Hamid S, Nicolaou S, Khosa F, Andrews G, Murray N, Abdellatif W, Qamar SR. Dual-Energy CT: A Paradigm Shift in Acute Traumatic Abdomen. Can Assoc Radiol J 2020; 71:371-387. [DOI: 10.1177/0846537120905301] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Abdominal trauma, one of the leading causes of death under the age of 45, can be broadly classified into blunt and penetrating trauma, based on the mechanism of injury. Blunt abdominal trauma usually results from motor vehicle collisions, fall from heights, assaults, and sports and is more common than penetrating abdominal trauma, which is usually seen in firearm injuries and stab wounds. In both blunt and penetrating abdominal trauma, an optimized imaging approach is mandatory to exclude life-threatening injuries. Easy availability of the portable ultrasound in the emergency department and trauma bay makes it one of the most commonly used screening imaging modalities in the abdominal trauma, especially to exclude hemoperitoneum. Evaluation of the visceral and vascular injuries in a hemodynamically stable patient, however, warrants intravenous contrast-enhanced multidetector computed tomography scan. Dual-energy computed tomography with its postprocessing applications such as iodine selective imaging and virtual monoenergetic imaging can reliably depict the conspicuity of traumatic solid and hollow visceral and vascular injuries.
Collapse
Affiliation(s)
- Saira Hamid
- Emergency and Trauma Radiology, Vancouver General Hospital, University of British Columbia, Vancouver, British Columbia, Canada
| | - Savvas Nicolaou
- Emergency and Trauma Radiology, Vancouver General Hospital, University of British Columbia, Vancouver, British Columbia, Canada
| | - Faisal Khosa
- Emergency and Trauma Radiology, Vancouver General Hospital, University of British Columbia, Vancouver, British Columbia, Canada
| | - Gordon Andrews
- Emergency and Trauma Radiology, Vancouver General Hospital, University of British Columbia, Vancouver, British Columbia, Canada
| | - Nicolas Murray
- Emergency and Trauma Radiology, Vancouver General Hospital, University of British Columbia, Vancouver, British Columbia, Canada
| | - Waleed Abdellatif
- Emergency and Trauma Radiology, Vancouver General Hospital, University of British Columbia, Vancouver, British Columbia, Canada
| | - Sadia Raheez Qamar
- Emergency and Trauma Radiology, Vancouver General Hospital, University of British Columbia, Vancouver, British Columbia, Canada
| |
Collapse
|
18
|
Abstract
OBJECTIVE. The objective of this study was to demonstrate the feasibility of dual-energy CT (DECT) for locoregional staging of breast cancer and differentiation of tumor histotypes. MATERIALS AND METHODS. From January 2016 to July 2017, a total of 31 patients (mean [± SD] age, 55.8 ± 14.8 years) with breast cancer diagnosed by needle biopsy who underwent preoperative contrast-enhanced DECT for staging purposes were selected from a retrospective review of institutional databases. Monochromatic images obtained at 40 and 70 keV were evaluated by two readers who determining the number of hypervascularized tumors present and the largest tumor diameter for each breast. The attenuation values and iodine concentration of tumors and normal breast tissue and the ratios of these findings in each tissue type were recorded. Cancers were classified as ductal carcinoma in situ, invasive ductal carcinoma, and invasive lobular carcinoma. The reference standard was the final pathologic finding after surgery. RESULTS. A total of 64 tumor lesions were found at histopathologic analysis versus 67 on DECT for 34 breasts (three bilateral cancers were included). Nonparametric statistics were used. The largest lesion diameter observed DECT was 33.2 ± 20.5 mm versus 31.8 ± 20.5 mm on pathologic analysis, and cancer distribution was correctly classified for 31 of 34 (91%) cases. ROC curves derived from lesion iodine concentration showed that the optimal thresholds for distinguishing infiltrating carcinomas (invasive lobular and ductal carcinomas) and from other lesions were 1.70 mg/mL (sensitivity, 94.9%; specificity, 93.0%; AUC value, 0.968). ROC curves derived from the ratio of the iodine concentration in lesions to that in normal breast parenchyma showed that 6.13 was the optimal threshold to distinguish invasive ductal carcinoma from other lesions (sensitivity, 87.0%; specificity, 81.1%; AUC value, 0.914). CONCLUSION. DECT is feasible and seems to be a reliable tool for locoregional staging of breast cancer.
Collapse
|
19
|
Bottari A, Silipigni S, Carerj ML, Cattafi A, Maimone S, Marino MA, Mazziotti S, Pitrone A, Squadrito G, Ascenti G. Dual-source dual-energy CT in the evaluation of hepatic fractional extracellular space in cirrhosis. LA RADIOLOGIA MEDICA 2020; 125:7-14. [PMID: 31587181 DOI: 10.1007/s11547-019-01089-7] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Accepted: 09/25/2019] [Indexed: 01/02/2023]
Abstract
BACKGROUND One of the main features of liver fibrosis is the expansion of the interstitial space. All water-soluble CT contrast agents remain confined in the vascular and interstitial space constituting the fractional extracellular space (fECS). Indirect measure of its expansion can be quantified during equilibrium phase with CT. The goal of this prospective study was to assess the feasibility of dual-energy CT (DECT) with iodine quantification at equilibrium phase in the evaluation of significant fibrosis or cirrhosis. METHODS Thirty-eight cirrhotic patients (according to Child-Pugh and MELD scores), scheduled for liver CT, were enrolled in the study group. Twenty-four patients undergoing CT urography with a 10-min excretory phase were included in the control group. fECS was calculated as the ratio of the iodine concentration of liver parenchyma to that of the aorta, multiplied by 1 minus hematocrit. RESULTS Final study and control group were, respectively, composed of 22 and 20 patients. Mean hepatic fECS value was statistically greater in study group (P < 0.05). Positive correlation was observed between hepatic fECS value and MELD score (r = 0.64, P < 0.05). Analysis of variance showed statistical differences between control group and the Child-Pugh grades and between Child-Pugh A and B patients and Child-Pugh C patients (P < 0.05). ROC curves analysis yielded an optimum fECS cutoff value of 26.3% for differentiation of control group and cirrhotic patients (AUC 0.88; 86% sensitivity, 85% specificity). CONCLUSIONS Dual-source DECT is a feasible, noninvasive method for the assessment of significant liver fibrosis or cirrhosis.
Collapse
Affiliation(s)
- Antonio Bottari
- Section of Radiological Sciences, Department of Biomedical, Dental Sciences and Morphological and Functional Imaging, University of Messina, Policlinico "G. Martino", Via Consolare Valeria n.1, 98100, Messina, Italy
| | - Salvatore Silipigni
- Section of Radiological Sciences, Department of Biomedical, Dental Sciences and Morphological and Functional Imaging, University of Messina, Policlinico "G. Martino", Via Consolare Valeria n.1, 98100, Messina, Italy.
| | - Maria Ludovica Carerj
- Section of Radiological Sciences, Department of Biomedical, Dental Sciences and Morphological and Functional Imaging, University of Messina, Policlinico "G. Martino", Via Consolare Valeria n.1, 98100, Messina, Italy
| | - Antonino Cattafi
- Section of Radiological Sciences, Department of Biomedical, Dental Sciences and Morphological and Functional Imaging, University of Messina, Policlinico "G. Martino", Via Consolare Valeria n.1, 98100, Messina, Italy
| | - Sergio Maimone
- Division of Clinical and Molecular Hepatology, University of Messina, Policlinico "G. Martino", Via Consolare Valeria 1, 98100, Messina, Italy
| | - Maria Adele Marino
- Section of Radiological Sciences, Department of Biomedical, Dental Sciences and Morphological and Functional Imaging, University of Messina, Policlinico "G. Martino", Via Consolare Valeria n.1, 98100, Messina, Italy
| | - Silvio Mazziotti
- Section of Radiological Sciences, Department of Biomedical, Dental Sciences and Morphological and Functional Imaging, University of Messina, Policlinico "G. Martino", Via Consolare Valeria n.1, 98100, Messina, Italy
| | - Alessia Pitrone
- Section of Radiological Sciences, Department of Biomedical, Dental Sciences and Morphological and Functional Imaging, University of Messina, Policlinico "G. Martino", Via Consolare Valeria n.1, 98100, Messina, Italy
| | - Giovanni Squadrito
- Division of Clinical and Molecular Hepatology, University of Messina, Policlinico "G. Martino", Via Consolare Valeria 1, 98100, Messina, Italy
| | - Giorgio Ascenti
- Section of Radiological Sciences, Department of Biomedical, Dental Sciences and Morphological and Functional Imaging, University of Messina, Policlinico "G. Martino", Via Consolare Valeria n.1, 98100, Messina, Italy
| |
Collapse
|
20
|
Gao L, Lv Y, Jin Y, Han F, Yao Z, Yang J, Zhang J. Differential diagnosis of hepatic cancerous nodules and cirrhosis nodules by spectral CT imaging: a feasibility study. Acta Radiol 2019; 60:1602-1608. [PMID: 30943752 DOI: 10.1177/0284185119840230] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- Lu Gao
- Department of Radiology, Huashan Hospital of Fudan University, Shanghai, PR China
- Department of Diagnostic Radiology, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, PR China
| | - Yi Lv
- Department of Radiology, Huashan Hospital of Fudan University, Shanghai, PR China
| | - Yingying Jin
- Department of Radiology, Huashan Hospital of Fudan University, Shanghai, PR China
| | - Fang Han
- Department of Radiology, Huashan Hospital of Fudan University, Shanghai, PR China
| | - Zhenwei Yao
- Department of Radiology, Huashan Hospital of Fudan University, Shanghai, PR China
| | - Jian Yang
- Department of Diagnostic Radiology, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, PR China
| | - Jiawen Zhang
- Department of Radiology, Huashan Hospital of Fudan University, Shanghai, PR China
| |
Collapse
|
21
|
Individually Body Weight-Adapted Contrast Media Application in Computed Tomography Imaging of the Liver at 90 kVp. Invest Radiol 2019; 54:177-182. [PMID: 30721159 DOI: 10.1097/rli.0000000000000525] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
OBJECTIVES The aim of the present study was to evaluate the attenuation and image quality (IQ) of a body weight-adapted contrast media (CM) protocol compared with a fixed injection protocol in computed tomography (CT) of the liver at 90 kV. MATERIALS AND METHODS One hundred ninety-nine consecutive patients referred for abdominal CT imaging in portal venous phase were included. Group 1 (n = 100) received a fixed CM dose with a total iodine load (TIL) of 33 g I at a flow rate of 3.5 mL/s, resulting in an iodine delivery rate (IDR) of 1.05 g I/s. Group 2 (n = 99) received a body weight-adapted CM protocol with a dosing factor of 0.4 g I/kg with a subsequent TIL adapted to the patients' weight. Injection time of 30 seconds was kept identical for all patients. Therefore, flow rate and IDR changed with different body weight. Patients were divided into 3 weight categories; 70 kg or less, 71 to 85 kg, and 86 kg or greater. Attenuation (HU) in 3 segments of the liver, signal-to-noise ratio, and contrast-to-noise ratio were used to evaluate objective IQ. Subjective IQ was assessed by a 5-point Likert scale. Differences between groups were statistically analyzed (P < 0.05 was considered statistically significant). RESULTS No significant differences in baseline characteristics were found between groups. The CM volume and TIL differed significantly between groups (P < 0.01), with mean values in group 1 of 110 mL and 33 g I, and in group 2 of 104.1 ± 21.2 mL and 31.2 ± 6.3 g I, respectively. Flow rate and IDR were not significantly different between groups (P > 0.05). Body weight-adapted protocoling led to more homogeneous enhancement of the liver parenchyma compared with a fixed protocol with a mean enhancement per weight category in group 2 of 126.5 ± 15.8, 128.2 ± 15.3, and 122.7 ± 21.2 HU compared with that in group 1 of 139.9 ± 21.4, 124.6 ± 24.8, and 116.2 ± 17.8 HU, respectively. CONCLUSIONS Body weight-adapted CM injection protocols result in more homogeneous enhancement of the liver parenchyma at 90 kV in comparison to a fixed CM volume with comparable objective and subjective IQ, whereas overall CM volume can be safely reduced in more than half of patients.
Collapse
|
22
|
Kang HJ, Lee JM, Lee SM, Yang HK, Kim RH, Nam JG, Karnawat A, Han JK. Value of virtual monochromatic spectral image of dual-layer spectral detector CT with noise reduction algorithm for image quality improvement in obese simulated body phantom. BMC Med Imaging 2019; 19:76. [PMID: 31462212 PMCID: PMC6714289 DOI: 10.1186/s12880-019-0367-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Accepted: 08/05/2019] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Dual-layer spectral detector CT (SDCT) may provide several theoretical advantages over pre-existing DECT approaches in terms of adjustment-free sampling number and dose modulation, beam hardening correction, and production spectral images by post-processing. In addition, by adopting noise reduction algorithm, high contrast resolution was expected even in low keV level. We surmised that this improvement would be beneficial to obese people. Therefore, our aim of study is to compare image quality of virtual monochromatic spectral images (VMI) and polychromatic images reconstructed from SDCT with different body size and radiation dose using anthropomorphic liver phantom. METHODS One small and one large size of body phantoms, each containing eight (four high- and four low-contrast) simulated focal liver lesions (FLLs) were scanned by SDCT (at 120 kVp) using different Dose Right Indexes (DRIs). VMI were reconstructed from spectral base images from 40 keV to 200 keV. Hybrid iterative reconstruction (iDose4) was used for polychromatic image reconstruction. Image noise and contrast to noise ratio (CNR) were compared. Five radiologists independently rated lesion conspicuity, diagnostic acceptability and subjective noise level in every image sets, and determined optimal keV level in VMI. RESULTS Compare with conventional polychromatic images, VMI showed superior CNR at low keV level regardless of phantom size at every examined DRIs (Ps < 0.05). As body size increased, VMI had more gradual CNR decrease and noise increase than conventional polychromatic images. For low contrast FLLs in large phantom, lesion conspicuities at low radiation dose levels (DRI 16 and 19) were significantly increased in VMI (Ps < 0.05). Subjective image noise and diagnostic acceptabilities were significantly improved at VMI in both phantom size. CONCLUSIONS VMI of dual-layer spectral detector CT with noise reduction algorithm provides improved CNR, noise reduction, and better subjective image quality in imaging of obese simulated liver phantom compared with polychromatic images. This may hold promise for improving detection of liver lesions and improved imaging of obese patients.
Collapse
Affiliation(s)
- Hyo-Jin Kang
- Department of Radiology, Seoul National University Hospital, Seoul, 03080 South Korea
- Department of Radiology, Seoul National University College of Medicine, 101 Daehangno, Jongno-gu, Seoul, 03080 South Korea
| | - Jeong Min Lee
- Department of Radiology, Seoul National University Hospital, Seoul, 03080 South Korea
- Department of Radiology, Seoul National University College of Medicine, 101 Daehangno, Jongno-gu, Seoul, 03080 South Korea
- Institute of Radiation Medicine, Seoul National University College Medical Research Center, Seoul, 03080 South Korea
| | - Sang Min Lee
- Department of Radiology, Hallym University Sacred Heart Hospital, Anyang, 14068 South Korea
| | - Hyun Kyung Yang
- Department of Medical imaging, Toronto General hospital, Toronto, Canada
| | - Ri Hyeon Kim
- Department of Radiology, Seoul National University Hospital, Seoul, 03080 South Korea
| | - Ju Gang Nam
- Department of Radiology, Seoul National University Hospital, Seoul, 03080 South Korea
| | - Aruna Karnawat
- Department of Radiology, Nizam’s Institute of Medical Sciences, Hyderabad, 500082 India
| | - Joon Koo Han
- Department of Radiology, Seoul National University Hospital, Seoul, 03080 South Korea
- Department of Radiology, Seoul National University College of Medicine, 101 Daehangno, Jongno-gu, Seoul, 03080 South Korea
- Institute of Radiation Medicine, Seoul National University College Medical Research Center, Seoul, 03080 South Korea
| |
Collapse
|
23
|
Euler A, Solomon J, FitzGerald PF, Samei E, Nelson RC. Can Realistic Liver Tissue Surrogates Accurately Quantify the Impact of Reduced-kV Imaging on Attenuation and Contrast of Parenchyma and Lesions? Acad Radiol 2019; 26:640-650. [PMID: 30269958 DOI: 10.1016/j.acra.2018.08.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2018] [Revised: 07/28/2018] [Accepted: 08/08/2018] [Indexed: 10/28/2022]
Abstract
RATIONALE AND OBJECTIVES To assess if a liquid tissue surrogate for the liver (LTSL) can emulate contrast-enhanced liver parenchyma and lesions and quantify the impact of reduced-kV imaging as a function of lesion contrast, phase of enhancement, and phantom size. MATERIALS AND METHODS First, CT attenuation of LTSL- and water-iodine solutions were measured as a function of iodine concentration and tube potential. For each solution, the iodine concentration was determined to emulate liver parenchyma at 120 kV. CT attenuation for both solutions was predicted for different tube potentials and compared to published patient data. Second, liver parenchyma in late arterial phase (LA: +92 HU at 120 kV) and portal venous phase (PV: +112 HU at 120 kV) was emulated using LTSL-iodine and a two-size phantom. Fourteen setups of hyper- and hypoattenuating lesions (lesion-to-parenchyma contrast (CLP) = -50 to +50HU) were created. Each combination of CLP, phase, and size was imaged at 80, 100, 120, and 140 kV at constant radiation dose. CT attenuation, CLP, and lesion-to-parenchyma contrast-to-noise ratio (CNRLP) were assessed and compared to a theoretical model. RESULTS LTSL-iodine more accurately emulated the CT attenuation of liver parenchyma across different tube potentials compared to water-iodine solutions. The theoretical model was confirmed by the empirical measurements using LTSL-iodine solutions: attenuation, CLP, and CNRLP increased when the tube potential decreased (p < 0.001). This trend was independent of lesion contrast, phase, and size. The absolute improvement in CLP and CNRLP, however, was inversely related to the magnitude of CLP at 140kV. CONCLUSION LTSL accurately emulated the energy-dependent CT attenuation characteristics of contrast-enhanced liver parenchyma and lesions. The relative improvement in CLP and CNRLP by applying reduced-kV imaging was independent of lesion contrast, phase, and size while the absolute improvement decreased for low-contrast lesions.
Collapse
|
24
|
Improved imaging of colorectal liver metastases using single-source, fast kVp-switching, dual-energy CT: preliminary results. Pol J Radiol 2019; 83:e643-e649. [PMID: 30800204 PMCID: PMC6384510 DOI: 10.5114/pjr.2018.80347] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2018] [Accepted: 11/05/2018] [Indexed: 12/03/2022] Open
Abstract
Purpose Computed tomography remains the first-choice modality for assessment of colorectal cancer liver metastases (CRLM). Dual-energy computed tomography (DECT) is a relatively new technique that is becoming increasingly available. One of the advantages of DECT is the ability to maximise iodine detection. Our aim was to test whether single-source, fast kVp-switching DECT can improve imaging quality of CRLM compared to conventional (polychromatic) CT. Material and methods Twenty consecutive patients were enrolled into a preliminary prospective study. The scanning protocol consisted of four phases: non-contrast with standard 120 kV tube voltage and three post-contrast phases with rapid voltage switching. As a result, three sets of images were reconstructed: pre- and postcontrast polychromatic (PR), monochromatic (MR), and iodine concentration map (IM). To compare the sensitivity of the tested reconstructions, the number of CRLMs and the maximum diameter of the largest lesion were calculated. Objective image quality was measured as signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). The radiation dose was expressed as CTDIvol. Results Imaging was successfully performed in all patients. The number of detected lesions was significantly lower on PR images than on IM and MR 50-70 keV (mean number: 4.20 and 4.45, respectively). IM and MR at 70 keV presented the highest quality. SNR was significantly higher for IM and 70 keV images than for other reconstructions. The mean radiation dose was 14.61 mGy for non-contrast 120 kV scan and 17.89 mGy for single DECT scan (p < 0.05). Conclusions DECT is a promising tool for CRLM imaging. IM and low-photon energy MR present the highest differences in contrast between metastases and the normal liver parenchyma.
Collapse
|
25
|
Nagayama Y, Iyama A, Oda S, Taguchi N, Nakaura T, Utsunomiya D, Kikuchi Y, Yamashita Y. Dual-layer dual-energy computed tomography for the assessment of hypovascular hepatic metastases: impact of closing k-edge on image quality and lesion detectability. Eur Radiol 2018; 29:2837-2847. [PMID: 30377793 DOI: 10.1007/s00330-018-5789-0] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2018] [Revised: 08/17/2018] [Accepted: 09/21/2018] [Indexed: 12/27/2022]
Abstract
OBJECTIVES To evaluate the image quality of virtual-monoenergetic-imaging (VMI) from dual-layer dual-energy CT (DLCT) for the assessment of hypovascular liver metastases and its effect on lesion detectability. METHODS Eighty-one patients with hypovascular-liver-metastases undergoing portal-venous-phase abdominal DLCT were included. Polyenergetic-images (PEI) and VMI at 40-200 keV (VMI40-200, 10-keV interval) were reconstructed. Image noise, tumor-to-liver contrast, and contrast-to-noise ratio (CNR) of hepatic parenchyma and metastatic nodules (n = 288) were measured to determine the optimal monoenergetic levels. Two radiologists independently and subjectively assessed the image quality (image contrast, image noise, and diagnostic confidence) of PEI and optimal VMI on 5-point scales to determine the best energy. For 38 patients having up to 10 metastases each with diameters < 25 mm (153 lesions), we compared blindly assessed lesion detectability and conspicuity between PEI and VMI at the best energy. RESULTS Image noise of VMI40-200 was consistently lower than that of PEI (p < 0.01). Tumor-to-liver contrast and CNR increased as the energy decreased with CNR at VMI40-70 being higher than that observed on PEI (p < 0.01). The highest subjective score for diagnostic confidence was assigned at VMI40 followed by VMI50-70, all of which were significantly better than that of PEI (p < 0.01, kappa = 0.75). Lesion detectability at VMI40 was significantly superior to PEI, especially for lesions with diameters of < 10 mm (p < 0.01, kappa ≥ 0.6). CONCLUSIONS VMI40-70 provided a better subjective and objective image quality for the evaluation of hypovascular liver metastases, and the lesion detectability was improved with use of VMI40 compared with conventional PEI. KEY POINTS • DLCT-VMI at 40-70 keV provides a superior subjective and objective image quality compared with conventional PEI for the assessment of hypovascular hepatic metastases during portal venous phase. • Tumor-to-liver contrast and CNR of hypovascular hepatic metastases was maximized at 40 keV without a relevant increase in the image noise. • VMI at 40 keV yields a superior lesion detectability, especially for small (< 1 cm) metastatic nodules compared with conventional PEI.
Collapse
Affiliation(s)
- Yasunori Nagayama
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto, 860-8556, Japan.
| | - Ayumi Iyama
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Seitaro Oda
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Narumi Taguchi
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Takeshi Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Daisuke Utsunomiya
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Yoko Kikuchi
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Yasuyuki Yamashita
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-ku, Kumamoto, 860-8556, Japan
| |
Collapse
|
26
|
Dual-energy CT in patients with colorectal cancer: Improved assessment of hypoattenuating liver metastases using noise-optimized virtual monoenergetic imaging. Eur J Radiol 2018; 106:184-191. [DOI: 10.1016/j.ejrad.2018.07.027] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Revised: 07/25/2018] [Accepted: 07/29/2018] [Indexed: 01/01/2023]
|
27
|
Dual-Energy CT Iodine Mapping and 40-keV Monoenergetic Applications in the Diagnosis of Acute Bowel Ischemia. AJR Am J Roentgenol 2018; 211:564-570. [DOI: 10.2214/ajr.18.19554] [Citation(s) in RCA: 53] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
28
|
Characterization of Small Incidental Indeterminate Hypoattenuating Hepatic Lesions: Added Value of Single-Phase Contrast-Enhanced Dual-Energy CT Material Attenuation Analysis. AJR Am J Roentgenol 2018; 211:571-579. [DOI: 10.2214/ajr.17.19170] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
29
|
Wortman JR, Sodickson AD. Pearls, Pitfalls, and Problems in Dual-Energy Computed Tomography Imaging of the Body. Radiol Clin North Am 2018; 56:625-640. [PMID: 29936951 DOI: 10.1016/j.rcl.2018.03.007] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Dual-energy computed tomography (DECT) is an exciting technology that is increasing in routine use and has the potential for significant clinical impact. With the advancement of DECT, it is important for radiologists to be aware of potential challenges with DECT acquisition and postprocessing, and to have a basic knowledge of unique artifacts and diagnostic pitfalls that can occur when interpreting DECT scans and DECT postprocessed images. This article serves as a practical overview of potential problems and diagnostic pitfalls associated with DECT, and steps that can be taken to avoid them.
Collapse
Affiliation(s)
- Jeremy R Wortman
- Division of Emergency Radiology, Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115, USA.
| | - Aaron D Sodickson
- Division of Emergency Radiology, Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115, USA
| |
Collapse
|
30
|
|
31
|
Wortman JR, Uyeda JW, Fulwadhva UP, Sodickson AD. Dual-Energy CT for Abdominal and Pelvic Trauma. Radiographics 2018. [DOI: 10.1148/rg.2018170058] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Jeremy R. Wortman
- From the Department of Radiology, Division of Emergency Radiology, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis St, Boston, MA 02115
| | - Jennifer W. Uyeda
- From the Department of Radiology, Division of Emergency Radiology, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis St, Boston, MA 02115
| | - Urvi P. Fulwadhva
- From the Department of Radiology, Division of Emergency Radiology, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis St, Boston, MA 02115
| | - Aaron D. Sodickson
- From the Department of Radiology, Division of Emergency Radiology, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis St, Boston, MA 02115
| |
Collapse
|
32
|
Multi-detector CT: Liver protocol and recent developments. Eur J Radiol 2017; 97:101-109. [PMID: 29153359 DOI: 10.1016/j.ejrad.2017.10.026] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2017] [Revised: 10/18/2017] [Accepted: 10/26/2017] [Indexed: 02/07/2023]
Abstract
Multi-detector computed tomography is today the workhorse in the evaluation of the vast majority of patients with known or suspected liver disease. Reasons for that include widespread availability, robustness and repeatability of the technique, time-efficient image acquisitions of large body volumes, high temporal and spatial resolution as well as multiple post-processing capabilities. However, as the technique employs ionizing radiation and intravenous iodine-based contrast media, the associated potential risks have to be taken into account. In this review article, liver protocols in clinical practice are discussed with emphasis on optimisation strategies. Furthermore, recent developments such as perfusion CT and dual-energy CT and their applications are presented.
Collapse
|
33
|
Parakh A, Baliyan V, Sahani DV. Dual-Energy CT in Focal and Diffuse Liver Disease. CURRENT RADIOLOGY REPORTS 2017. [DOI: 10.1007/s40134-017-0226-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
34
|
Fulton N, Rajiah P. Abdominal Applications of a Novel Detector-Based Spectral CT. Curr Probl Diagn Radiol 2017; 47:110-118. [PMID: 28673603 DOI: 10.1067/j.cpradiol.2017.05.001] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Accepted: 05/16/2017] [Indexed: 12/21/2022]
Abstract
Detector-based spectral computed tomography (SDCT) is a recently introduced technology that uses a single x-ray tube and 2 layers of detectors to simultaneously collect low- and high-energy data. In this article, we provide an overview of this novel SDCT technology in abdominal imaging. Several applications of SDCT in abdominal imaging are discussed and illustrated, along with a brief description of current literature on the status of dual-energy computed tomography in these applications. This includes urinary calculus composition, characterization of masses (renal, adrenal, hepatic, and others), tumor perfusion, improving vascular contrast, improving lesion conspicuity, decreasing artifacts, and reducing radiation dose.
Collapse
Affiliation(s)
- Nicholas Fulton
- Department of Radiology, University Hospital Cleveland Medical Center, Cleveland, OH
| | - Prabhakar Rajiah
- Cardiothoracic Imaging, Department of Radiology, UT Southwestern Medical Center, Dallas, TX 75390.
| |
Collapse
|
35
|
Impact of model-based iterative reconstruction on low-contrast lesion detection and image quality in abdominal CT: a 12-reader-based comparative phantom study with filtered back projection at different tube voltages. Eur Radiol 2017; 27:5252-5259. [DOI: 10.1007/s00330-017-4825-9] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2016] [Revised: 02/08/2017] [Accepted: 03/20/2017] [Indexed: 12/21/2022]
|
36
|
Benveniste AP, de Castro Faria S, Broering G, Ganeshan DM, Tamm EP, Iyer RB, Bhosale P. Potential Application of Dual-Energy CT in Gynecologic Cancer: Initial Experience. AJR Am J Roentgenol 2017; 208:695-705. [PMID: 28075606 DOI: 10.2214/ajr.16.16227] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of this article is to review the use of dual-energy CT (DECT) in the assessment of gynecologic cancer. CONCLUSION DECT has the potential to improve diagnostic performance, may improve the ability to differentiate between simple cystic lesions and primary ovarian cancer, and may also improve the detection of musculoskeletal and liver metastases. Additional studies will be needed to determine the direction of future developments and the degree to which DECT will affect the imaging and management of gynecologic cancer.
Collapse
Affiliation(s)
- Ana Paula Benveniste
- 1 Department of Radiology-Breast Imaging, Baylor College of Medicine, One Baylor Plaza, MS: BCM360, Houston, TX 77030
| | - Silvana de Castro Faria
- 2 Department of Radiology-Abdominal Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Gregory Broering
- 3 Diagnostic and Interventional Radiology, Baylor College of Medicine, Houston, TX
| | - Dhakshina Moorthy Ganeshan
- 2 Department of Radiology-Abdominal Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Eric P Tamm
- 2 Department of Radiology-Abdominal Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Revathy B Iyer
- 2 Department of Radiology-Abdominal Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Priya Bhosale
- 2 Department of Radiology-Abdominal Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX
| |
Collapse
|
37
|
Uhrig M, Simons D, Bonekamp D, Schlemmer HP. Improved detection of melanoma metastases by iodine maps from dual energy CT. Eur J Radiol 2017; 90:27-33. [PMID: 28583644 DOI: 10.1016/j.ejrad.2017.02.024] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2016] [Revised: 12/29/2016] [Accepted: 02/15/2017] [Indexed: 01/01/2023]
Abstract
OBJECTIVE Metastatic disease in melanoma has an unpredictable nature with deposits in rare locations such as musculature. Dual energy CT (DECT) provides high contrast-visualization of enhancement by using spectral properties of iodine. Purpose of this study was to evaluate whether iodine maps from DECT improve lesion detection in staging examinations of melanoma patients. METHODS This retrospective study was approved by IRB and written informed consent was obtained from all patients. 75 contrast-enhanced DECT scans (thorax and abdomen) from 75 melanoma patients (n=69 stage IV; n=6 stage III) were analysed. For each patient, conventional CT and iodine maps were reviewed independently by two radiologists. The number of lesions detected by reviewing the iodine maps following conventional CT was recorded. Unweighted Cohens Kappa coefficient (κ) was used for concordance analysis, Wilcoxon test for comparing lesion detection rates. RESULTS In 26 patients, at least one reader found additional lesions on iodine maps (inter-reader agreement 89%, κ=0.74 (0.742-0.747)). Compared to grey-scale images, mean detection rate for metastases improved from 86% (range 82-90) to 94% (90-99%) (p≤0.01), for muscle metastases from 8% (8-8%) to 99% (98-100%) (p≤0.06). Findings included 2 pulmonary emboli. CONCLUSION Iodine maps from DECT improve detection of metastases, especially muscle metastases, and relevant findings in staging examinations of melanoma patients.
Collapse
Affiliation(s)
- Monika Uhrig
- German Cancer Research Center (DKFZ), Department of Radiology, Im Neuenheimer Feld 280, D-69120, Heidelberg, Germany.
| | - David Simons
- German Cancer Research Center (DKFZ), Department of Radiology, Im Neuenheimer Feld 280, D-69120, Heidelberg, Germany
| | - David Bonekamp
- German Cancer Research Center (DKFZ), Department of Radiology, Im Neuenheimer Feld 280, D-69120, Heidelberg, Germany
| | - Heinz-Peter Schlemmer
- German Cancer Research Center (DKFZ), Department of Radiology, Im Neuenheimer Feld 280, D-69120, Heidelberg, Germany
| |
Collapse
|
38
|
Dual-Energy CT of Incidental Findings in the Abdomen: Can We Reduce the Need for Follow-Up Imaging? AJR Am J Roentgenol 2016; 207:W58-W68. [DOI: 10.2214/ajr.16.16087] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
39
|
Performance of adaptive iterative dose reduction 3D integrated with automatic tube current modulation in radiation dose and image noise reduction compared with filtered-back projection for 80-kVp abdominal CT: Anthropomorphic phantom and patient study. Eur J Radiol 2016; 85:1666-72. [DOI: 10.1016/j.ejrad.2016.07.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2016] [Revised: 07/04/2016] [Accepted: 07/11/2016] [Indexed: 01/16/2023]
|
40
|
Switching Monopolar Radiofrequency Ablation Using a Separable Cluster Electrode in Patients with Hepatocellular Carcinoma: A Prospective Study. PLoS One 2016; 11:e0161980. [PMID: 27575787 PMCID: PMC5004876 DOI: 10.1371/journal.pone.0161980] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2016] [Accepted: 08/03/2016] [Indexed: 12/19/2022] Open
Abstract
OBJECTIVE This study was conducted to evaluate the outcomes of multi-channel switching RFA using a separable cluster electrode in patients with HCC. METHODS From November 2011 to July 2013, 79 patients with 98 HCCs < 5 cm were enrolled and treated with RFA using a multi-channel switching radiofrequency system and a separable cluster electrode under the guidance of a real-time fusion imaging system. The primary and secondary endpoints were the 3-year local tumor progression (LTP) rate and recurrence-free survival (RFS) rate, respectively. For post hoc analyses, LTP, RFS, and major complication rates were retrospectively compared with a historical control group treated with RFA using the same radiofrequency system but with multiple internally-cooled electrodes. RESULTS The technique success rate of the 98 tumors was 100%. Cumulative 1-year, 2-year, and 3-year LTP rates were 3.4%, 6.9%, and 12.4%, respectively. For patient-level data, cumulative 1-year, 2-year, and 3-year RFS rates were 83.9%, 68.6%, and 45.4%, respectively. On post hoc analyses, none of the baseline characteristics showed a significant difference between the separable cluster electrode and multiple internally-cooled electrodes group. Cumulative LTP and RFS rates of the two groups also showed no significant difference (p = 0.401 and p = 0.881, respectively). Finally, major complication rates of the separable cluster electrode group (5.0%, 4/79) and multiple internally-cooled electrodes group (5.9%, 4/74) were also comparable (p = 1.000). CONCLUSION Switching monopolar RFA using a separable cluster electrode is a feasible and efficient technique for the treatment of HCCs smaller than 5 cm, providing comparable local tumor control to multiple internally-cooled electrodes. TRIAL REGISTRATION ClinicalTrials.gov NCT02745483.
Collapse
|
41
|
|
42
|
Laroia ST, Bhadoria AS, Venigalla Y, Chibber GK, Bihari C, Rastogi A, Sarin SK. Role of dual energy spectral computed tomography in characterization of hepatocellular carcinoma: Initial experience from a tertiary liver care institute. Eur J Radiol Open 2016; 3:162-71. [PMID: 27504474 DOI: 10.1016/j.ejro.2016.05.007] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2016] [Accepted: 05/26/2016] [Indexed: 12/20/2022] Open
Abstract
OBJECTIVE To investigate dual-energy spectral CT in characterization of hepatocellular Carcinoma (HCC) in patients with chronic liver disease. METHODS Dynamic computed tomography (CT) was performed in 3600 patients (2879 males; 721 females, mean age 50.9 ± 11.9 years) with working clinical diagnosis of liver cirrhosis for hepatocellular carcinoma screening and other clinical indications. The study was conducted over a period of 3 years. During dynamic CT scanning, spectral (monochromatic) and routine (polychromatic) CT acquisitions were obtained on a single tube, dual energy, 64 slice multi-detector CT scanner. Imaging findings were studied on routine CT. On the basis of routine CT findings, indeterminate lesions (lesions not showing characteristic hypervascularity followed by washout on dynamic routine CT scan) that were referred for biopsy or surgery were segregated. A retrospective blinded review of the lesions, acquired by the spectral CT acquisitions was done with the help of gem stone imaging (GSI) software to characterize these lesions. All the above lesions were analyzed qualitatively in the arterial phase for lesion conspicuity as well as quantitatively using the monochromatic data sets and nodule Iodine concentration on material density maps, respectively. This data was studied with respect to predictability of HCC using the spectral CT technique. Iodine density of the lesion, surrounding liver parenchyma, and lesion to liver parenchyma ratio (LLR) were derived and statistically analyzed. Histopathology of the lesion in question was treated as gold standard for analysis. RESULTS It was observed via statistical analysis that the value of iodine density of the lesion on material density sets of ≥29.5 mg/dl, enabled a discriminatory power of 86.5%, sensitivity of 90.5% with 95% confidence Interval (CI) (69.2-98.8%) and specificity of 81.2% with 95% Confidence Interval (54.4-95.9%) in predicting HCC. Qualitative assessment also showed higher lesion conspicuity with spectral CT image sets as compared to routine CT data. CONCLUSION This study reveals that spectral imaging is an excellent qualitative as well as a quantitative tool for assessing and predicting hepatocellular carcinoma in cirrhotic patients.
Collapse
Affiliation(s)
- S T Laroia
- Department of Radiology, Institute of Liver and Biliary Sciences, Sector D-1, Vasant Kunj, New Delhi 110070, India
| | - Ajeet Singh Bhadoria
- Department of Community Medicine, Institute of Liver & Biliary Sciences, Sector D-1, Vasant Kunj, New Delhi 110 070, India
| | - Yamini Venigalla
- Department of Radiology, Institute of Liver and Biliary Sciences, Sector D-1, Vasant Kunj, New Delhi 110070, India
| | - G K Chibber
- Department of Research, Institute of Liver & Biliary Sciences, Sector D-1, Vasant Kunj, New Delhi 110 070, India
| | - Chagan Bihari
- Department of Hepatopathology, Institute of Liver & Biliary Sciences, Sector D-1, Vasant Kunj, New Delhi 110 070, India
| | - Archana Rastogi
- Department of Hepatopathology, Institute of Liver & Biliary Sciences, Sector D-1, Vasant Kunj, New Delhi 110 070, India
| | - S K Sarin
- Department of Hepatology, Institute of Liver and Biliary Sciences, Sector D-1, Vasant Kunj, New Delhi 110070, India
| |
Collapse
|
43
|
Uhrig M, Simons D, Kachelrieß M, Pisana F, Kuchenbecker S, Schlemmer HP. Advanced abdominal imaging with dual energy CT is feasible without increasing radiation dose. Cancer Imaging 2016; 16:15. [PMID: 27329159 PMCID: PMC4915171 DOI: 10.1186/s40644-016-0073-5] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2016] [Accepted: 06/14/2016] [Indexed: 01/28/2023] Open
Abstract
Background Dual energy CT (DECT) has proven its potential in oncological imaging. Considering the repeated follow-up examinations, radiation dose should not exceed conventional single energy CT (SECT). Comparison studies on the same scanner with a large number of patients, considering patient geometries and image quality, and exploiting full potential of SECT dose reduction are rare. Purpose of this retrospective study was to compare dose of dual source DECT versus dose-optimized SECT abdominal imaging in clinical routine. Methods One hundred patients (62y (±14)) had either contrast-enhanced SECT including automatic voltage control (44) or DECT (56). CT dose index (CTDIvol), size-specific dose-estimate (SSDE) and dose-length product (DLP) were reported. Image noise (SD) was recorded as mean of three ROIs placed in subcutaneous fat and normalized to dose by \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ SDn=SD\times \sqrt{CDTIvol} $$\end{document}SDn=SD×CDTIvol. For dose-normalized contrast-to-noise ratio (CNRD), mean attenuation of psoas muscle (CTmuscle) and subcutaneous fat (CTfat) were compared by CNRD = (CTmuscle − CTfat)/SDn. Statistical significance was tested with two-sided t-test (α = 0.05). Results There was no significant difference (p < 0.05) between DECT and SECT: Mean CTDIvol was 14.2 mGy (±3.9) (DECT) and 14.3 mGy (±4.5) (SECT). Mean DLP was 680 mGy*cm (±220) (DECT) and 665 mGy*cm (±231) (SECT). Mean SSDE was 15.7 mGy (±1.9) (DECT) and 16.1 mGy (±2.5) (SECT). Mean SDn was 42.2 (±13.9) HU \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ *\sqrt{\mathrm{mGy}} $$\end{document}*mGy (DECT) and 47.8 (±14.9) HU \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ *\sqrt{\mathrm{mGy}} $$\end{document}*mGy (SECT). Mean CNRD was 3.9 (±1.3) \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ {\mathrm{mGy}}^{-\frac{1}{2}} $$\end{document}mGy−12. (DECT) and 4.0 (±1.3) \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ {\mathrm{mGy}}^{-\frac{1}{2}} $$\end{document}mGy−12 (SECT). Conclusion Abdominal DECT is feasible without increasing radiation dose or deteriorating image quality, even compared to dose-optimized SECT including automatic voltage control. Thus DECT can contribute to sophisticated oncological imaging without dose penalty.
Collapse
Affiliation(s)
- Monika Uhrig
- Department of Radiology, German Cancer Research Center (DKFZ) Heidelberg, Im Neuenheimer Feld 280, D-69120, Heidelberg, Germany.
| | - David Simons
- Department of Radiology, German Cancer Research Center (DKFZ) Heidelberg, Im Neuenheimer Feld 280, D-69120, Heidelberg, Germany
| | - Marc Kachelrieß
- Department of Medical Physics in Oncology, Division of X-Ray Imaging and Computed Tomography, German Cancer Research Center (DKFZ) Heidelberg, Im Neuenheimer Feld 280, D-69120, Heidelberg, Germany
| | - Francesco Pisana
- Department of Medical Physics in Oncology, Division of X-Ray Imaging and Computed Tomography, German Cancer Research Center (DKFZ) Heidelberg, Im Neuenheimer Feld 280, D-69120, Heidelberg, Germany
| | - Stefan Kuchenbecker
- Department of Medical Physics in Oncology, Division of X-Ray Imaging and Computed Tomography, German Cancer Research Center (DKFZ) Heidelberg, Im Neuenheimer Feld 280, D-69120, Heidelberg, Germany
| | - Heinz-Peter Schlemmer
- Department of Radiology, German Cancer Research Center (DKFZ) Heidelberg, Im Neuenheimer Feld 280, D-69120, Heidelberg, Germany
| |
Collapse
|
44
|
Advanced virtual monoenergetic computed tomography of hyperattenuating and hypoattenuating liver lesions: ex-vivo and patient experience in various body sizes. Invest Radiol 2016; 50:695-702. [PMID: 26002623 DOI: 10.1097/rli.0000000000000171] [Citation(s) in RCA: 84] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To determine the value of advanced virtual monoenergetic images (mono+) from dual-energy computed tomography (CT) of hyperattenuating and hypoattenuating liver lesions in various phantom sizes and patients in comparison with standard monoenergetic images (mono). MATERIALS AND METHODS Anthropomorphic phantoms simulating 4 patient sizes (S, 300 × 200 mm; M, 350 × 250 mm; L, 400 × 300 mm; and XL, 600 × 450 mm) with a liver insert containing both hyperattenuating and hypoattenuating iodine-containing lesions were imaged with dose-equivalent dual-energy (100/150 Sn kilovolt [peak] [kV{p}]) and single-energy (120 kV[p]) protocols on a 192-slice dual-source CT system. In addition, 4 patients with 3 hypoattenuating and 3 hyperattenuating hepatocellular carcinoma were included and underwent dual-energy CT imaging with the same scanner at similar kV(p) settings (100/150 Sn kV[p]). Images were reconstructed with standard mono and with the mono+ algorithm at 10-kiloelectron volt (keV) intervals from 40 to 190 keV. Attenuation of the liver and lesions were measured, and contrast-to-noise ratios (CNRs) were calculated. Lesion conspicuity was rated by 2 blinded independent readers in all mono and mono+ data sets from 40 to 190 keV using a 5-point Likert scale (1, lowest conspicuity; and 5, highest conspicuity). RESULTS Attenuation in the liver and in both hyperattenuating and hypoattenuating lesions did not differ between mono and mono+ (P = 0.41-0.49). Noise on mono+ was significantly lower than on mono for all phantom sizes (P < 0.05) and was increasing with phantom size. Hyperattenuating lesion CNR was highest for mono+ images at 40 keV in the S phantom (6.73), with significantly higher CNR for mono+ than for mono and for single energy (120 kV[p]) in all phantom sizes (all P < 0.001) except for the XL phantom. Hypoattenuating lesion CNR was highest for high-keV mono+ being significantly higher than on mono and on single-energy (120 kV[p]) images (all P < 0.001), except for the XL phantom with significantly higher CNR for mono (1.3) compared with mono+ (0.47) and 120 kV(p) (1.26). In patients, CNR curves of hyperattenuating hepatocellular carcinoma were in accordance with the phantom data, whereas hypoattenuating lesions demonstrate varying curves, some being in accordance with findings in phantoms. Interreader agreement for lesion conspicuity was very good (intraclass correlation, 0.95), with higher conspicuity scores for mono+ than for mono and single energy (120 kV[p]) at all phantom sizes (all P < 0.05) and within patients. CONCLUSION Our ex vivo and patient data demonstrate added value for imaging of both hyperattenuating and hypoattenuating liver lesions with advanced virtual monoenergetic dual-energy CT by decreased noise, increased CNR, and higher lesion conspicuity, although with limitations in XL body sizes.
Collapse
|
45
|
Kim S, Shuman WP. Clinical Applications of Dual-Energy Computed Tomography in the Liver. Semin Roentgenol 2016; 51:284-291. [PMID: 27743564 DOI: 10.1053/j.ro.2016.05.019] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Sooah Kim
- Department of Radiology, University of Washington, Seattle, WA.
| | | |
Collapse
|
46
|
Tian SF, Liu AL, Liu JH, Sun MY, Wang HQ, Liu YJ. Application of computed tomography virtual noncontrast spectral imaging in evaluation of hepatic metastases: a preliminary study. Chin Med J (Engl) 2015; 128:610-4. [PMID: 25698191 PMCID: PMC4834770 DOI: 10.4103/0366-6999.151656] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Objective: The objective was to qualitatively and quantitatively evaluate hepatic metastases using computed tomography (CT) virtual noncontrast (VNC) spectral imaging in a retrospective analysis. Methods: Forty hepatic metastases patients underwent CT scans including the conventional true noncontrast (TNC) and the tri-phasic contrast-enhanced dual energy spectral scans in the hepatic arterial, portal venous, and equilibrium phases. The tri-phasic spectral CT images were used to obtain three groups of VNC images including in the arterial (VNCa), venous (VNCv), and equilibrium (VNCe) phase by the material decomposition process using water and iodine as a base material pair. The image quality and the contrast-to-noise ratio (CNR) of metastasis of the four groups were compared with ANOVA analysis. The metastasis detection rates with the four nonenhanced image groups were calculated and compared using the Chi-square test. Results: There were no significant differences in image quality among TNC, VNCa and VNCv images (P > 0.05). The quality of VNCe images was significantly worse than that of other three groups (P < 0.05). The mean CNR of metastasis in the TNC and VNCs images was 1.86, 2.42, 1.92, and 1.94, respectively; the mean CNR of metastasis in VNCa images was significantly higher than that in other three groups (P < 0.05), while no statistically significant difference was observed among VNCv, VNCe and TNC images (P > 0.05). The metastasis detection rate of the four nonenhanced groups with no statistically significant difference (P > 0.05). Conclusions: The quality of VNCa and VNCv images is identical to that of TNC images, and the metastasis detection rate in VNC images is similar to that in TNC images. VNC images obtained from arterial phase show metastases more clearly. Thus, VNCa imaging may be a surrogate to TNC imaging in hepatic metastasis diagnosis.
Collapse
Affiliation(s)
| | - Ai-Lian Liu
- Department of Radiology, First Affiliated Hospital of Dalian Medical University, Dalian, Shenyang 116011, China
| | | | | | | | | |
Collapse
|
47
|
Bajpai S, Kambadakone A, Guimaraes AR, Arellano RS, Gervais DA, Sahani D. Image-guided Treatment in the Hepatobiliary System: Role of Imaging in Treatment Planning and Posttreatment Evaluation. Radiographics 2015; 35:1393-418. [DOI: 10.1148/rg.2015140281] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
48
|
McLaughlin PD, Mallinson P, Lourenco P, Nicolaou S. Dual-Energy Computed Tomography: Advantages in the Acute Setting. Radiol Clin North Am 2015; 53:619-38, vii. [PMID: 26046502 DOI: 10.1016/j.rcl.2015.02.016] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
The aim of this article is to inform and update emergency radiologists in respect of the clinically relevant benefits that dual-energy computed tomography (CT) contributes over conventional single-energy CT in the emergency setting using practical imaging examples. Particular emphasis will be placed on acute gout, bone marrow edema, acute renal colic, acute cardiovascular and neurovascular emergencies aswell as characterization of abdominal incidentalomas. The relevant scientific literature will be summarized and limitations of the technique also will be emphasized to provide the reader with a rounded concept of the current state of technology.
Collapse
Affiliation(s)
- Patrick D McLaughlin
- Department of Radiology, Vancouver General Hospital, University of British Columbia, 899 West 12th Avenue, Vancouver V5Z 1M9, Canada.
| | - Paul Mallinson
- Department of Radiology, Vancouver General Hospital, University of British Columbia, 899 West 12th Avenue, Vancouver V5Z 1M9, Canada
| | - Pedro Lourenco
- Department of Radiology, Vancouver General Hospital, University of British Columbia, 899 West 12th Avenue, Vancouver V5Z 1M9, Canada
| | - Savvas Nicolaou
- Department of Radiology, Vancouver General Hospital, University of British Columbia, 899 West 12th Avenue, Vancouver V5Z 1M9, Canada
| |
Collapse
|
49
|
Current Status of Imaging to Evaluate Liver Metastases From Colorectal Cancer. CURRENT COLORECTAL CANCER REPORTS 2015. [DOI: 10.1007/s11888-015-0272-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
50
|
Possible Contrast Media Reduction with Low keV Monoenergetic Images in the Detection of Focal Liver Lesions: A Dual-Energy CT Animal Study. PLoS One 2015. [PMID: 26203652 PMCID: PMC4512723 DOI: 10.1371/journal.pone.0133170] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
Abstract
Objective To investigate the feasibility of dual-energy CT for contrast media (CM) reduction in the diagnosis of hypervascular and hypovascular focal liver lesions (FLL). Subjects and Methods The Institutional Animal Care and Use Committee approved this study. VX2 tumors were implanted in two different segments of the liver in 13 rabbits. After 2 weeks, two phase contrast enhanced CT scans including the arterial phase (AP) and portal-venous phase (PVP) were performed three times with 24-hour intervals with three different concentrations of iodine, 300 (I300), 150 (I150) and 75 mg I/mL (I75). The mean HU and standard deviation (SD) were measured in the liver, the hypervascular portion of the VX2 tumor which represented hypervascular tumors, and the central necrotic area of the VX2 tumor which represented hypovascular tumors in 140kVp images with I300 as a reference standard and in monoenergetic images (between 40keV and 140keV) with I150 and I75. The contrast-to-noise ratio (CNR) for FLLs and the ratio of the CNRs (CNRratio) between monoenergetic image sets with I150 and I75, and the reference standard were calculated. Results For hypervascular lesions, the CNRratio was not statistically different from 1.0 between 40keV and 70keV images with I150, whereas the CNRratio was significantly lower than 1.0 in all keV images with I75. For hypovascular lesions, the CNRratio was similar to or higher than 1.0 between 40keV and 80keV with I150 and between 40keV and 70keV with I75. Conclusions With dual-energy CT, the total amount of CM might be halved in the diagnosis of hypervascular FLLs and reduced to one-fourth in the diagnosis of hypovascular FLLs, while still preserving CNRs.
Collapse
|