Camera L, D'Ambrosio V, Pinto L, Paludi A, Liuzzi R, De Cicco R, Ponsiglione A, Lagnese MG, Maurea S, Brunetti A. Fixed rate vs fixed injection duration in single-pass contrast-enhanced abdominal multi-detector CT: effects on vascular enhancement. Br J Radiol 2025; 98:114-123. [PMID: 39374549 DOI: 10.1093/bjr/tqae202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 07/27/2024] [Accepted: 10/02/2024] [Indexed: 10/09/2024] Open
Abstract
OBJECTIVES To evaluate the effects on vascular enhancement of either a fixed rate (FR) or a fixed injection duration (FID) in single-pass (SP) contrast-enhanced abdominal multi-detector CT (CE-MDCT). METHODS Ninety-nine (54 M; 45 F; aged 18-86 years) patients with nontraumatic acute abdomen underwent a SP CE-MDCT after i.v. injection of 1.7 cc/Kg of a nonionic iodinated contrast media (370 mgI/mL) performed with either a FR (2 cc/s; Group A) or a FID (55 s; Group B). In both groups, patients were further stratified according to total body weight (kg) as follows: 40-60 (L); 61-80 (M); 81-100 (H). Signal- (SNR) and contrast-to-noise ratios (CNR) were calculated for the liver and for both abdominal aorta (AA) and main portal vein (MPV). Statistical analysis was performed by Student t- or Chi-square test for continuous and categorical data, respectively, whereas post hoc analysis was performed by the Mann-Whitney test (P < .05). RESULTS There were no significant differences in demographic and physical characteristics between Group A (n = 50; 53 ± 20 years; BMI = 23.4 ± 4.4) and Group B (n = 50; 51 ± 17 years; BMI 22.7 ± 4.2). Whereas overlapping findings were observed in the M sub-groups (n = 40), SNR and CNR were significantly higher (P < .01) in Group B for both AA and MPV in the high (H) weight sub-groups (n = 20) while not significant differences were observed in the low (L) weight sub-groups (n = 40) despite a significantly lower injection rate (1.6 ± 0.2 cc/s, P < .01) in Group B. CONCLUSION A FID results in an overall better vascular enhancement than a FR in SP CE-MDCT. ADVANCES IN KNOWLEDGE Single-pass is an optimized contrast-enhanced abdominal CT protocol combining the benefits of vascular and visceral enhancement and characterized by a customized scan delay tailored around a monophasic contrast injection. In single-pass protocol, a fixed injection duration (55 s) results in an overall better vascular enhancement than a fixed rate (2 cc/s) and should be therefore regarded as the injection modality of choice.
Collapse
Affiliation(s)
- Luigi Camera
- Department of Advanced Biomedical Sciences-Section of Radiology, University "Federico II", Via S. Pansini 5 - 80131 Naples, Italy
| | - Vincenzo D'Ambrosio
- Department of Advanced Biomedical Sciences-Section of Radiology, University "Federico II", Via S. Pansini 5 - 80131 Naples, Italy
| | | | | | - Raffaele Liuzzi
- Institute of Biostructures and Bioimaging (National Research Council), 80131 Naples, Italy
| | - Rossella De Cicco
- Department of Advanced Biomedical Sciences-Section of Radiology, University "Federico II", Via S. Pansini 5 - 80131 Naples, Italy
| | - Andrea Ponsiglione
- Department of Advanced Biomedical Sciences-Section of Radiology, University "Federico II", Via S. Pansini 5 - 80131 Naples, Italy
| | - Maria Grazia Lagnese
- Department of Advanced Biomedical Sciences-Section of Radiology, University "Federico II", Via S. Pansini 5 - 80131 Naples, Italy
| | - Simone Maurea
- Department of Advanced Biomedical Sciences-Section of Radiology, University "Federico II", Via S. Pansini 5 - 80131 Naples, Italy
| | - Arturo Brunetti
- Department of Advanced Biomedical Sciences-Section of Radiology, University "Federico II", Via S. Pansini 5 - 80131 Naples, Italy
| |
Collapse
|
2
|
Martens B, Bosschee JGA, Van Kuijk SMJ, Jeukens CRLPN, Brauer MTH, Wildberger JE, Mihl C. Finding the optimal tube current and iterative reconstruction strength in liver imaging; two needles in one haystack. PLoS One 2022; 17:e0266194. [PMID: 35390018 PMCID: PMC8989341 DOI: 10.1371/journal.pone.0266194] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Accepted: 03/15/2022] [Indexed: 11/19/2022] Open
Abstract
Objectives
The aim of the study was to find the lowest possible tube current and the optimal iterative reconstruction (IR) strength in abdominal imaging.
Material and methods
Reconstruction software was used to insert noise, simulating the use of a lower tube current. A semi-anthropomorphic abdominal phantom (Quality Assurance in Radiology and Medicine, QSA-543, Moehrendorf, Germany) was used to validate the performance of the ReconCT software (S1 Appendix). Thirty abdominal CT scans performed with a standard protocol (120 kVref, 150 mAsref) scanned at 90 kV, with dedicated contrast media (CM) injection software were selected. There were no other in- or exclusion criteria. The software was used to insert noise as if the scans were performed with 90, 80, 70 and 60% of the full dose. Consequently, the different scans were reconstructed with filtered back projection (FBP) and IR strength 2, 3 and 4. Both objective (e.g. Hounsfield units [HU], signal to noise ratio [SNR] and contrast to noise ratio [CNR]) and subjective image quality were evaluated. In addition, lesion detection was graded by two radiologists in consensus in another 30 scans (identical scan protocol) with various liver lesions, reconstructed with IR 3, 4 and 5.
Results
A tube current of 60% still led to diagnostic objective image quality (e.g. SNR and CNR) when IR strength 3 or 4 were used. IR strength 4 was preferred for lesion detection. The subjective image quality was rated highest for the scans performed at 90% with IR 4.
Conclusion
A tube current reduction of 10–40% is possible in case IR 4 is used, leading to the highest image quality (10%) or still diagnostic image quality (40%), shown by a pairwise comparison in the same patients.
Collapse
Affiliation(s)
- Bibi Martens
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands
- * E-mail:
| | | | - Sander M. J. Van Kuijk
- Department of Clinical Epidemiology and Medical Technology Assessment, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Cécile R. L. P. N. Jeukens
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Maikel T. H. Brauer
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Joachim E. Wildberger
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands
| | - Casper Mihl
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
- CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands
| |
Collapse
|
3
|
Agostini A, Borgheresi A, Bruno F, Natella R, Floridi C, Carotti M, Giovagnoni A. New advances in CT imaging of pancreas diseases: a narrative review. Gland Surg 2020; 9:2283-2294. [PMID: 33447580 PMCID: PMC7804533 DOI: 10.21037/gs-20-551] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2020] [Accepted: 09/09/2020] [Indexed: 12/13/2022]
Abstract
Computed tomography (CT) plays a pivotal role as a diagnostic tool in many diagnostic and diffuse pancreatic diseases. One of the major limits of CT is related to the radiation exposure of young patients undergoing repeated examinations. Besides the standard CT protocol, the most recent technological advances, such as low-voltage acquisitions with high performance X-ray tubes and iterative reconstructions, allow for significant optimization of the protocol with dose reduction. The variety of CT tools are further expanded by the introduction of dual energy: the production of energy-selective images (i.e., virtual monochromatic images) improves the image contrast and lesion detection while the material-selective images (e.g., iodine maps or virtual unenhanced images) are valuable for lesion detection and dose reduction. The perfusion techniques provide diagnostic and prognostic information lesion and parenchymal vascularization and interstitium. Both dual energy and perfusion CT have the potential for pushing the limits of conventional CT from morphological evaluation to quantitative imaging applied to inflammatory and oncological diseases. Advances in post-processing of CT images, such as pancreatic volumetry, texture analysis and radiomics provide relevant information for pancreatic function but also for the diagnosis, management and prognosis of pancreatic neoplasms. Artificial intelligence is promising for optimization of the workflow in qualitative and quantitative analyses. Finally, basic concepts on the role of imaging on screening of pancreatic diseases will be provided.
Collapse
Affiliation(s)
- Andrea Agostini
- Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, Ancona (AN), Italy
- Department of Radiology, University Hospital “Umberto I – Lancisi – Salesi”, Ancona (AN), Italy
| | - Alessandra Borgheresi
- Department of Radiology, University Hospital “Umberto I – Lancisi – Salesi”, Ancona (AN), Italy
| | - Federico Bruno
- Department of Biotechnological and Applied Sciences, University of L’Aquila, L’Aquila, Italy
| | - Raffaele Natella
- Department of Precision Medicine, University of Campania “L. Vanvitelli”, Naples, Italy
| | - Chiara Floridi
- Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, Ancona (AN), Italy
- Department of Radiology, University Hospital “Umberto I – Lancisi – Salesi”, Ancona (AN), Italy
| | - Marina Carotti
- Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, Ancona (AN), Italy
- Department of Radiology, University Hospital “Umberto I – Lancisi – Salesi”, Ancona (AN), Italy
| | - Andrea Giovagnoni
- Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, Ancona (AN), Italy
- Department of Radiology, University Hospital “Umberto I – Lancisi – Salesi”, Ancona (AN), Italy
| |
Collapse
|
4
|
Choi MH, Lee YJ, Jung SE. A LESSON FROM AUTOMATIC TUBE VOLTAGE SELECTION: FEASIBILITY OF 100 kVp IN PORTAL VENOUS PHASE ABDOMINAL CT. RADIATION PROTECTION DOSIMETRY 2020; 188:424-431. [PMID: 31998958 DOI: 10.1093/rpd/ncz302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Revised: 10/17/2019] [Accepted: 12/23/2019] [Indexed: 06/10/2023]
Abstract
PURPOSE To evaluate the relationship between ATVS-recommended tube voltage and patient body habitus and to compare radiation dose and diagnostic performance between fixed 120-kVp and ATVS protocols in portal venous phase abdomen CT. METHODS A total of 907 portal venous phase abdominal CTs were evaluated. Radiation dose in the ATVS protocol was compared according to tube voltage (80, 100 or 120 kVp). Quantitative image analysis and diagnostic performance were compared between 81 pairs of CT using ATVS and fixed 120-kVp protocols. RESULTS Most CT examinations with ATVS were performed with 80 or 100 kVp. The average reduction rate of radiation dose in the ATVS protocol was 15.4%. There was no significant difference in diagnostic performance (p = 0.388) between ATVS and fixed 120-kVp protocols. CONCLUSIONS In conclusion, ATVS frequently selected 80 or 100 kVp for portal venous phase abdominal CT without impairing the diagnostic performance, even with filtered back projection.
Collapse
Affiliation(s)
- Moon Hyung Choi
- Department of Radiology, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
- Catholic Smart Imaging Center, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
- Department of Radioogy, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Young Joon Lee
- Department of Radiology, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
- Catholic Smart Imaging Center, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
- Department of Radioogy, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Seung Eun Jung
- Department of Radiology, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
- Catholic Smart Imaging Center, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
- Department of Radioogy, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| |
Collapse
|
5
|
|
6
|
Eller A, Wiesmüller M, Wüst W, Heiss R, Kopp M, Saake M, Brand M, Uder M, May MM. Carotid CTA at the Lowest Tube Voltage (70 kV) in Comparison with Automated Tube Voltage Adaption. AJNR Am J Neuroradiol 2019; 40:1374-1382. [PMID: 31296525 DOI: 10.3174/ajnr.a6108] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Accepted: 05/26/2019] [Indexed: 12/28/2022]
Abstract
BACKGROUND AND PURPOSE CTA is the imaging modality of choice in many institutions for the evaluation of the supraaortic vessels, but radiation exposure remains a matter of concern. Our aim was to evaluate a 70-kV protocol for CT angiography of the carotid arteries with respect to image quality and radiation exposure compared with automated tube voltage adaption. MATERIALS AND METHODS A total of 90 consecutive patients were included in this prospective study and randomized to the study group (n = 45, 70 kV) or control group (n = 45, automated tube voltage adaptation). Volume CT dose indices and dose-length products were recorded in the examination protocol. Image quality was assessed as arterial vessel contrast, signal-to-noise ratio, contrast-to-noise ratio, and contrast-to-noise ratio in reference to the radiation dose. Subjective overall image-quality analysis, image-artifact analysis, and diagnostic evaluation were performed by 2 observers by using a 4-point Likert scale. RESULTS Radiation exposure was significantly lower in the study group (volume CT dose index reduced by 22%, dose-length product reduction by 20%; each P < .001). Contrast (P = .15), SNR (P = .4), and contrast-to-noise ratio (P = .5) did not show significant differences between the groups. The contrast-to-noise ratio in reference to the radiation dose was not significantly increased using the study protocol (P = .2). Subjective image quality and visualization of pathologic findings did not differ significantly between the groups. CONCLUSIONS Carotid CTA using the lowest available voltage (70 kV) is feasible at very-low-dose levels, while overall image quality is comparable with protocols using automated tube voltage selection.
Collapse
Affiliation(s)
- A Eller
- From the Department of Radiology (A.E., M.W., W.W., R.H., M.K., M.S., M.B., M.U., M.M.M.), University Hospital Erlangen, Erlangen, Germany
| | - M Wiesmüller
- From the Department of Radiology (A.E., M.W., W.W., R.H., M.K., M.S., M.B., M.U., M.M.M.), University Hospital Erlangen, Erlangen, Germany
| | - W Wüst
- From the Department of Radiology (A.E., M.W., W.W., R.H., M.K., M.S., M.B., M.U., M.M.M.), University Hospital Erlangen, Erlangen, Germany
| | - R Heiss
- From the Department of Radiology (A.E., M.W., W.W., R.H., M.K., M.S., M.B., M.U., M.M.M.), University Hospital Erlangen, Erlangen, Germany
| | - M Kopp
- From the Department of Radiology (A.E., M.W., W.W., R.H., M.K., M.S., M.B., M.U., M.M.M.), University Hospital Erlangen, Erlangen, Germany
| | - M Saake
- From the Department of Radiology (A.E., M.W., W.W., R.H., M.K., M.S., M.B., M.U., M.M.M.), University Hospital Erlangen, Erlangen, Germany
| | - M Brand
- From the Department of Radiology (A.E., M.W., W.W., R.H., M.K., M.S., M.B., M.U., M.M.M.), University Hospital Erlangen, Erlangen, Germany
| | - M Uder
- From the Department of Radiology (A.E., M.W., W.W., R.H., M.K., M.S., M.B., M.U., M.M.M.), University Hospital Erlangen, Erlangen, Germany
- Imaging Science Institute (M.U., M.M.M.), Erlangen, Germany
| | - M M May
- From the Department of Radiology (A.E., M.W., W.W., R.H., M.K., M.S., M.B., M.U., M.M.M.), University Hospital Erlangen, Erlangen, Germany
- Imaging Science Institute (M.U., M.M.M.), Erlangen, Germany
| |
Collapse
|
7
|
Saltybaeva N, Krauss A, Alkadhi H. Technical Note: Radiation dose reduction from computed tomography localizer radiographs using a tin spectral shaping filter. Med Phys 2019; 46:544-549. [DOI: 10.1002/mp.13353] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Revised: 12/04/2018] [Accepted: 12/06/2018] [Indexed: 01/30/2023] Open
Affiliation(s)
- Natalia Saltybaeva
- Institute for Diagnostic and Interventional Radiology University Hospital Zurich Zurich Switzerland
| | - Andreas Krauss
- Computed Tomography Division Siemens Healthineers Forchheim Germany
| | - Hatem Alkadhi
- Institute for Diagnostic and Interventional Radiology University Hospital Zurich Zurich Switzerland
| |
Collapse
|
8
|
Abstract
OBJECTIVE The purpose of this article is to discuss the advances in CT acquisition and image postprocessing as they apply to imaging the pancreas and to conceptualize the role of radiogenomics and machine learning in pancreatic imaging. CONCLUSION CT is the preferred imaging modality for assessment of pancreatic diseases. Recent advances in CT (dual-energy CT, CT perfusion, CT volumetry, and radiogenomics) and emerging computational algorithms (machine learning) have the potential to further increase the value of CT in pancreatic imaging.
Collapse
|
9
|
O'Hora L, Foley S. Iterative reconstruction and automatic tube voltage selection reduce clinical CT radiation doses and image noise. Radiography (Lond) 2018; 24:28-32. [DOI: 10.1016/j.radi.2017.08.010] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2017] [Revised: 08/16/2017] [Accepted: 08/31/2017] [Indexed: 11/24/2022]
|
10
|
Scharf M, Brendel S, Melzer K, Hentschke C, May M, Uder M, Lell MM. Image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal CT, using Sinogram Affirmed Iterative Reconstruction (SAFIRE) technique in a longitudinal study. PLoS One 2017; 12:e0180302. [PMID: 28678818 PMCID: PMC5498038 DOI: 10.1371/journal.pone.0180302] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2016] [Accepted: 06/13/2017] [Indexed: 12/15/2022] Open
Abstract
Objective To step-wise evaluate image quality of sinogram-affirmed iterative reconstruction (SAFIRE) in reduced-dose (RD) thoracoabdominal computed tomography (CT) compared to full-dose (FD) and RD filtered back projection (FBP) in a longitudinal study. Materials and methods 122 patients were included in this prospective study. 49 patients (14 men: mean age ± SD, 56±0.4 years; 35 women: 58±1.3 years) completed FD, RD1 (80%-dose) and RD2 (60%-dose) thoracoabdominal CT. Each CT dataset was reconstructed with FBP and SAFIRE. For quantitative image analysis image noise was measured in defined tissue regions. Qualitative image evaluation was performed according to the European Guidelines on Quality criteria for CT. Additionally artifacts, lesion conspicuity, and edge sharpness were assessed. Results Compared to FD-FBP noise in soft tissue increased by 12% in RD1-FBP and 27% in RD2-FBP reconstructions, whereas SAFIRE lead to a decrease of 28% (RD1) and 17% (RD2), respectively (all p <0.001). Visually sharp reproduction, lesion conspicuity, edge sharpness of pathologic findings, and overall image quality did not differ statistically significant between FD-FBP and RD-SAFIRE datasets. Image quality decreased in RD1- and RD2-FBP compared to FD-FBP, reaching statistically significance in RD2 datasets (p <0.001). In RD1- and RD2-FBP (p <0.001) streak artifacts were noted. Conclusion Using SAFIRE the reference mAs in thoracoabdominal CT can be reduced by at least 30% in clinical routine without loss of image quality or diagnostic information.
Collapse
Affiliation(s)
- Michael Scharf
- Department of Radiology, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany
- * E-mail:
| | - Stephanie Brendel
- Department of Radiology, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany
| | - Katja Melzer
- Department of Radiology, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany
| | - Christian Hentschke
- Institute of Sport Science and Sport, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany
| | - Matthias May
- Department of Radiology, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany
| | - Michael Uder
- Department of Radiology, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany
| | - Michael M. Lell
- Department of Radiology, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany
| |
Collapse
|
11
|
Lell MM, Fleischmann U, Pietsch H, Korporaal JG, Haberland U, Mahnken AH, Flohr TG, Uder M, Jost G. Relationship between low tube voltage (70 kV) and the iodine delivery rate (IDR) in CT angiography: An experimental in-vivo study. PLoS One 2017; 12:e0173592. [PMID: 28319203 PMCID: PMC5358883 DOI: 10.1371/journal.pone.0173592] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2016] [Accepted: 02/23/2017] [Indexed: 02/07/2023] Open
Abstract
Objective Very short acquisition times and the use of low-kV protocols in CTA demand modifications in the contrast media (CM) injection regimen. The aim of this study was to optimize the use of CM delivery parameters in thoraco-abdominal CTA in a porcine model. Materials and methods Six pigs (55–68 kg) were examined with a dynamic CTA protocol (454 mm scan length, 2.5 s temporal resolution, 70 s total acquisition time). Four CM injection protocols were applied in a randomized order. 120 kV CTA protocol: (A) 300 mg iodine/kg bodyweight (bw), IDR = 1.5 g/s (flow = 5 mL/s), injection time (ti) 12 s (60 kg bw). 70 kV CTA protocols: 150 mg iodine/kg bw: (B) IDR = 0.75 g/s (flow = 2.5 mL/s), ti = 12 s (60 kg bw); (C) IDR = 1.5 g/s (flow = 5 mL/s), ti = 12 s (60 kg bw); (D) IDR = 3.0 g/s (flow = 10 mL/s), ti = 3 s (60 kg bw). The complete CM bolus shape was monitored by creating time attenuation curves (TAC) in different vascular territories. Based on the TAC, the time to peak (TTP) and the peak enhancement were determined. The diagnostic window (relative enhancement > 300 HU), was calculated and compared to visual inspection of the corresponding CTA data sets. Results The average relative arterial peak enhancements after baseline correction were 358.6 HU (A), 356.6 HU (B), 464.0 HU (C), and 477.6 HU (D). The TTP decreased with increasing IDR and decreasing ti, protocols A and B did not differ significantly (systemic arteries, p = 0.843; pulmonary arteries, p = 0.183). The delay time for bolus tracking (trigger level 100 HU; target enhancement 300 HU) for single-phase CTA was comparable for protocol A and B (3.9, 4.3 s) and C and D (2.4, 2.0 s). The scan window time frame was comparable for the different protocols by visual inspection of the different CTA data sets and by analyzing the TAC. Conclusions All protocols provided sufficient arterial enhancement. The use of a 70 kV CTA protocol is recommended because of a 50% reduction of total CM volume and a 50% reduced flow rate while maintaining the bolus profile. In contrast to pulmonary arterial enhancement, the systemic arterial enhancement improved only slightly increasing the IDR from 1.5 g/s to 3 g/s because of bolus dispersion of the very short bolus (3s) in the lungs.
Collapse
Affiliation(s)
- Michael M. Lell
- Department of Radiology and Nuclear Medicine, Paracelsus Medical University, Nuernberg, Germany
- * E-mail:
| | - Ulrike Fleischmann
- Department of Radiology, Friedrich-Alexander University Erlangen, Erlangen, Germany
| | - Hubertus Pietsch
- MR and CT Contrast Media Research, Bayer Healthcare, Berlin, Germany
| | | | | | | | | | - Michael Uder
- Department of Radiology and Nuclear Medicine, Paracelsus Medical University, Nuernberg, Germany
- Imaging Science Institute (ISI) Erlangen, Erlangen, Germany
| | - Gregor Jost
- MR and CT Contrast Media Research, Bayer Healthcare, Berlin, Germany
| |
Collapse
|
12
|
Automated Attenuation Based Tube Potential Selection of the Lower Extremity Runoff. J Comput Assist Tomogr 2017; 41:817-822. [DOI: 10.1097/rct.0000000000000602] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
13
|
Scout-Based Automated Tube Potential Selection Technique (kV Assist) in Enhanced Chest Computed Tomography: Effects on Radiation Exposure and Image Quality. J Comput Assist Tomogr 2016; 41:442-445. [PMID: 27759600 DOI: 10.1097/rct.0000000000000523] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
OBJECTIVE The aim of our study was to assess radiation dose reduction and image quality for enhanced chest CT examinations with a scout-based automated tube potential selection technique (kV Assist) compared with a standard 120-kV protocol. METHODS Prospective study of enhanced chest CT examinations was performed in 100 consecutive patients with kV Assist and in 100 consecutive patients with conventional 120-kV protocol on a multislice CT (Discovery CT750 HD). The body mass index, CT dose index volume, and dose length product were recorded from the examination protocol. Image noise and CT value was measured on region of interest, signal-to-noise ratio, and contrast-to-noise ratio was calculated. The subjective image quality was assessed by two radiologists blinded to the respective protocol with the use of a 3-grade scale (3, superior quality; 2, moderate quality; 1, inferior quality). RESULTS With kV Assist, the percentages of patients being scanned using 80, 100, and 120 kV were 12.0%, 80.0%, and 8.0%, respectively. The kilovolt setting was related with body mass index (r = 0.565, P = 0.000). Compared with the conventional 120 kV protocol, kV Assist allowed for an overall average decrease of 30.6% in CT dose index volume (kV Assist, 11.05 ± 4.78 mGy; 120 kV, 15.92 ± 6.89 mGy) (P < 0.001) and 32.3% in dose length product (kV Assist, 386.41 ± 184.02 mGy cm; 120 kV, 571.14 ± 286.68 mGy cm) (P < 0.001). In the kV Assist, mean attenuation of regions of interest inside the aorta was significantly higher than that in 120-kV protocols (kV Assist, 310.27 ± 73.70 HU; 120 kV, 239.44 ± 47.65 HU) (P < 0.001), resulting in increased contrast-to-noise ratio (kV Assist, 26.69 ± 7.78; 120 kV, 21.38 ± 6.05) (P < 0.001). There was no significant difference in subjective image quality scores between the 2 groups. CONCLUSIONS The use of attenuation-based kV Assist technique enables significant dose reduction in enhanced chest CT scan while improving arterial enhancement and preserving image quality at adequate levels.
Collapse
|
14
|
Park C, Gruber-Rouh T, Leithner D, Zierden A, Albrecht MH, Wichmann JL, Bodelle B, Elsabaie M, Scholtz JE, Kaup M, Vogl TJ, Beeres M. Single-source chest-abdomen-pelvis cancer staging on a third generation dual-source CT system: comparison of automated tube potential selection to second generation dual-source CT. Cancer Imaging 2016; 16:33. [PMID: 27724954 PMCID: PMC5057380 DOI: 10.1186/s40644-016-0093-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2016] [Accepted: 10/03/2016] [Indexed: 11/25/2022] Open
Abstract
Background Evaluation of latest generation automated attenuation-based tube potential selection (ATPS) impact on image quality and radiation dose in contrast-enhanced chest-abdomen-pelvis computed tomography examinations for gynaecologic cancer staging. Methods This IRB approved single-centre, observer-blinded retrospective study with a waiver for informed consent included a total of 100 patients with contrast-enhanced chest-abdomen-pelvis CT for gynaecologic cancer staging. All patients were examined with activated ATPS for adaption of tube voltage to body habitus. 50 patients were scanned on a third-generation dual-source CT (DSCT), and another 50 patients on a second-generation DSCT. Predefined image quality setting remained stable between both groups at 120 kV and a current of 210 Reference mAs. Subjective image quality assessment was performed by two blinded readers independently. Attenuation and image noise were measured in several anatomic structures. Signal-to-noise ratio (SNR) was calculated. For the evaluation of radiation exposure, CT dose index (CTDIvol) values were compared. Results Diagnostic image quality was obtained in all patients. The median CTDIvol (6.1 mGy, range 3.9–22 mGy) was 40 % lower when using the algorithm compared with the previous ATCM protocol (median 10.2 mGy · cm, range 5.8–22.8 mGy). A reduction in potential to 90 kV occurred in 19 cases, a reduction to 100 kV in 23 patients and a reduction to 110 kV in 3 patients of our experimental cohort. These patients received significantly lower radiation exposure compared to the former used protocol. Conclusion Latest generation automated ATPS on third-generation DSCT provides good diagnostic image quality in chest-abdomen-pelvis CT while average radiation dose is reduced by 40 % compared to former ATPS protocol on second-generation DSCT.
Collapse
Affiliation(s)
- Clara Park
- Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Tatjana Gruber-Rouh
- Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Doris Leithner
- Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Amelie Zierden
- Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Mortiz H Albrecht
- Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Julian L Wichmann
- Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Boris Bodelle
- Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Mohamed Elsabaie
- Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Jan-Erik Scholtz
- Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Moritz Kaup
- Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Thomas J Vogl
- Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Martin Beeres
- Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany.
| |
Collapse
|
15
|
Automated tube voltage selection in thoracoabdominal computed tomography at high pitch using a third-generation dual-source scanner: image quality and radiation dose performance. Invest Radiol 2015; 50:352-60. [PMID: 25591129 DOI: 10.1097/rli.0000000000000133] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
OBJECTIVES The objective of this study was to evaluate the radiation dose and image quality performance of thoracoabdominal examinations with an automated tube voltage selection (tube voltage adaptation), tube current modulation, and high pitch using a third-generation dual-source computed tomography (CT) compared intraindividually with 120-kV examinations with tube current modulation with special attention on clinically relevant lesions in the liver, the lungs, and extrahepatic soft tissues. MATERIALS AND METHODS This study was approved by the institutional review board. Computed tomography of the body was performed using a third-generation dual-source system in 95 patients (mean body mass index, 25 kg/m²; range, 18-35 kg/m²). For 49 of these patients, all calculated tube settings and resulting dose values were recorded for each of the 12 gradual contrast weightings of the tube voltage adaptation algorithm. Spiral CT was performed for all patients with an intermediate weighting (grade 7) in a portal venous phase at 120 reference kV, 180 reference mAs, and pitch of 1.55. Objective image quality was assessed on the basis of contrast-to-noise ratio. Subjective image quality was assessed on the basis of clarity and sharpness of anatomical and pathological structures as well as interfering beam hardening and spiral and motion artifacts (heart, lungs, diaphragm). Previous examinations on a 64-slice scanner served as reference. RESULTS All examinations were rated good or excellent for clinical diagnosis. Automated tube voltage selection resulted in significantly lower effective radiation dose (9.5 mSv) compared with the reference (12.0 mSv; P < 0.01). Contrast-to-noise ratio and image quality of soft tissue lesions were significantly increased (P < 0.01). Motion artifacts were significantly reduced (P < 0.01). CONCLUSIONS Automated tube voltage adaptation combined with high-pitch protocols allows for a substantial radiation dose reduction while substantially increasing the image quality, even at large-volume exposure.
Collapse
|
16
|
Third-generation dual-source CT of the neck using automated tube voltage adaptation in combination with advanced modeled iterative reconstruction: evaluation of image quality and radiation dose. Eur Radiol 2015; 26:2623-31. [PMID: 26560726 DOI: 10.1007/s00330-015-4099-z] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2015] [Revised: 10/28/2015] [Accepted: 10/29/2015] [Indexed: 02/03/2023]
|
17
|
Spearman JV, Schoepf UJ, Rottenkolber M, Driesser I, Canstein C, Thierfelder KM, Krazinski AW, De Cecco CN, Meinel FG. Effect of Automated Attenuation-based Tube Voltage Selection on Radiation Dose at CT: An Observational Study on a Global Scale. Radiology 2015; 279:167-74. [PMID: 26473641 DOI: 10.1148/radiol.2015141507] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To evaluate the effect of automated tube voltage selection (ATVS) on radiation dose at computed tomography (CT) worldwide encompassing all body regions and types of CT examinations. MATERIALS AND METHODS No patient information was accessed; therefore, institutional review board approval was not sought. Data from 86 centers across the world were analyzed. All CT interactions were automatically collected and transmitted to the CT vendor during two 6-week periods immediately before and 2 weeks after implementation of ATVS. A total of 164 323 unique CT studies were analyzed. Studies were categorized by body region and type of examination. Tube voltage and volume CT dose index (CTDIvol) were compared between examinations performed with ATVS and those performed before ATVS implementation. Descriptive statistical methods and multilevel linear regression models were used for analysis. RESULTS Across all types of CT examinations and body regions, CTDIvol was 14.7% lower in examinations performed with ATVS (n = 30 313) than in those performed before ATVS implementation (n = 79 275). Relative reductions in mean CTDIvol were most notable for temporal bone CT (-56.1%), peripheral runoff CT angiography (-48.6%), CT of the paranasal sinus (-39.6%), cerebral or carotid CT angiography (-36.4%), coronary CT angiography (-25.1%), and head CT (-23.9%). An increase in mean CTDIvol was observed for renal stone protocols (26.2%) and thoracic or lumbar spine examinations (6.6%). In the multilevel model with fixed effects ATVS and examination type, and the interaction of these variables and the random effect country, a significant influence on CTDIvol for all fixed efects was revealed (ATVS, P = .0031; examination type, P < .0001; interaction term, P < .0001). CONCLUSION ATVS significantly reduces radiation dose across most, but not all, body regions and types of CT examinations.
Collapse
Affiliation(s)
- James V Spearman
- From the Division of Cardiovascular Imaging, Department of Radiology and Radiological Science (J.V.S., U.J.S., A.W.K., C.N.D.C., F.G.M.) and Division of Cardiology, Department of Medicine (U.J.S.), Medical University of South Carolina, 25 Courtenay Dr, MSC 226, Charleston, SC 29425; Medizinische Klinik und Poliklinik IV, Ludwig-Maximilians-Universität, Munich, Germany (M.R.); Healthcare Division, Computed Tomography, Siemens, Forchheim, Germany (I.D.); Siemens Medical Solutions USA, Malvern, Pa (C.C.); Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany (K.M.T., F.G.M.); and Department of Radiological Sciences, Oncology and Pathology, University of Rome "Sapienza"-Polo Pontino, Latina, Italy (C.N.D.C.)
| | - U Joseph Schoepf
- From the Division of Cardiovascular Imaging, Department of Radiology and Radiological Science (J.V.S., U.J.S., A.W.K., C.N.D.C., F.G.M.) and Division of Cardiology, Department of Medicine (U.J.S.), Medical University of South Carolina, 25 Courtenay Dr, MSC 226, Charleston, SC 29425; Medizinische Klinik und Poliklinik IV, Ludwig-Maximilians-Universität, Munich, Germany (M.R.); Healthcare Division, Computed Tomography, Siemens, Forchheim, Germany (I.D.); Siemens Medical Solutions USA, Malvern, Pa (C.C.); Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany (K.M.T., F.G.M.); and Department of Radiological Sciences, Oncology and Pathology, University of Rome "Sapienza"-Polo Pontino, Latina, Italy (C.N.D.C.)
| | - Marietta Rottenkolber
- From the Division of Cardiovascular Imaging, Department of Radiology and Radiological Science (J.V.S., U.J.S., A.W.K., C.N.D.C., F.G.M.) and Division of Cardiology, Department of Medicine (U.J.S.), Medical University of South Carolina, 25 Courtenay Dr, MSC 226, Charleston, SC 29425; Medizinische Klinik und Poliklinik IV, Ludwig-Maximilians-Universität, Munich, Germany (M.R.); Healthcare Division, Computed Tomography, Siemens, Forchheim, Germany (I.D.); Siemens Medical Solutions USA, Malvern, Pa (C.C.); Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany (K.M.T., F.G.M.); and Department of Radiological Sciences, Oncology and Pathology, University of Rome "Sapienza"-Polo Pontino, Latina, Italy (C.N.D.C.)
| | - Ivo Driesser
- From the Division of Cardiovascular Imaging, Department of Radiology and Radiological Science (J.V.S., U.J.S., A.W.K., C.N.D.C., F.G.M.) and Division of Cardiology, Department of Medicine (U.J.S.), Medical University of South Carolina, 25 Courtenay Dr, MSC 226, Charleston, SC 29425; Medizinische Klinik und Poliklinik IV, Ludwig-Maximilians-Universität, Munich, Germany (M.R.); Healthcare Division, Computed Tomography, Siemens, Forchheim, Germany (I.D.); Siemens Medical Solutions USA, Malvern, Pa (C.C.); Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany (K.M.T., F.G.M.); and Department of Radiological Sciences, Oncology and Pathology, University of Rome "Sapienza"-Polo Pontino, Latina, Italy (C.N.D.C.)
| | - Christian Canstein
- From the Division of Cardiovascular Imaging, Department of Radiology and Radiological Science (J.V.S., U.J.S., A.W.K., C.N.D.C., F.G.M.) and Division of Cardiology, Department of Medicine (U.J.S.), Medical University of South Carolina, 25 Courtenay Dr, MSC 226, Charleston, SC 29425; Medizinische Klinik und Poliklinik IV, Ludwig-Maximilians-Universität, Munich, Germany (M.R.); Healthcare Division, Computed Tomography, Siemens, Forchheim, Germany (I.D.); Siemens Medical Solutions USA, Malvern, Pa (C.C.); Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany (K.M.T., F.G.M.); and Department of Radiological Sciences, Oncology and Pathology, University of Rome "Sapienza"-Polo Pontino, Latina, Italy (C.N.D.C.)
| | - Kolja M Thierfelder
- From the Division of Cardiovascular Imaging, Department of Radiology and Radiological Science (J.V.S., U.J.S., A.W.K., C.N.D.C., F.G.M.) and Division of Cardiology, Department of Medicine (U.J.S.), Medical University of South Carolina, 25 Courtenay Dr, MSC 226, Charleston, SC 29425; Medizinische Klinik und Poliklinik IV, Ludwig-Maximilians-Universität, Munich, Germany (M.R.); Healthcare Division, Computed Tomography, Siemens, Forchheim, Germany (I.D.); Siemens Medical Solutions USA, Malvern, Pa (C.C.); Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany (K.M.T., F.G.M.); and Department of Radiological Sciences, Oncology and Pathology, University of Rome "Sapienza"-Polo Pontino, Latina, Italy (C.N.D.C.)
| | - Aleksander W Krazinski
- From the Division of Cardiovascular Imaging, Department of Radiology and Radiological Science (J.V.S., U.J.S., A.W.K., C.N.D.C., F.G.M.) and Division of Cardiology, Department of Medicine (U.J.S.), Medical University of South Carolina, 25 Courtenay Dr, MSC 226, Charleston, SC 29425; Medizinische Klinik und Poliklinik IV, Ludwig-Maximilians-Universität, Munich, Germany (M.R.); Healthcare Division, Computed Tomography, Siemens, Forchheim, Germany (I.D.); Siemens Medical Solutions USA, Malvern, Pa (C.C.); Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany (K.M.T., F.G.M.); and Department of Radiological Sciences, Oncology and Pathology, University of Rome "Sapienza"-Polo Pontino, Latina, Italy (C.N.D.C.)
| | - Carlo N De Cecco
- From the Division of Cardiovascular Imaging, Department of Radiology and Radiological Science (J.V.S., U.J.S., A.W.K., C.N.D.C., F.G.M.) and Division of Cardiology, Department of Medicine (U.J.S.), Medical University of South Carolina, 25 Courtenay Dr, MSC 226, Charleston, SC 29425; Medizinische Klinik und Poliklinik IV, Ludwig-Maximilians-Universität, Munich, Germany (M.R.); Healthcare Division, Computed Tomography, Siemens, Forchheim, Germany (I.D.); Siemens Medical Solutions USA, Malvern, Pa (C.C.); Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany (K.M.T., F.G.M.); and Department of Radiological Sciences, Oncology and Pathology, University of Rome "Sapienza"-Polo Pontino, Latina, Italy (C.N.D.C.)
| | - Felix G Meinel
- From the Division of Cardiovascular Imaging, Department of Radiology and Radiological Science (J.V.S., U.J.S., A.W.K., C.N.D.C., F.G.M.) and Division of Cardiology, Department of Medicine (U.J.S.), Medical University of South Carolina, 25 Courtenay Dr, MSC 226, Charleston, SC 29425; Medizinische Klinik und Poliklinik IV, Ludwig-Maximilians-Universität, Munich, Germany (M.R.); Healthcare Division, Computed Tomography, Siemens, Forchheim, Germany (I.D.); Siemens Medical Solutions USA, Malvern, Pa (C.C.); Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany (K.M.T., F.G.M.); and Department of Radiological Sciences, Oncology and Pathology, University of Rome "Sapienza"-Polo Pontino, Latina, Italy (C.N.D.C.)
| |
Collapse
|
18
|
|
19
|
Estimated Patient Dose Indexes in Adult and Pediatric MDCT: Comparison of Automatic Tube Voltage Selection With Fixed Tube Current, Fixed Tube Voltage, and Weight-Based Protocols. AJR Am J Roentgenol 2015; 205:592-8. [DOI: 10.2214/ajr.14.13242] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
20
|
Automated tube voltage adaptation in combination with advanced modeled iterative reconstruction in thoracoabdominal third-generation 192-slice dual-source computed tomography: effects on image quality and radiation dose. Acad Radiol 2015; 22:1081-7. [PMID: 26163706 DOI: 10.1016/j.acra.2015.05.010] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2015] [Revised: 05/20/2015] [Accepted: 05/25/2015] [Indexed: 12/29/2022]
Abstract
RATIONALE AND OBJECTIVES To evaluate image quality and radiation exposure of portal venous-phase thoracoabdominal third-generation 192-slice dual-source computed tomography (DSCT) with automated tube voltage adaptation (TVA) in combination with advanced modeled iterative reconstruction (ADMIRE). MATERIALS AND METHODS Fifty-one patients underwent oncologic portal venous-phase thoracoabdominal follow-up CT twice within 7 months. The initial examination was performed on second-generation 128-slice DSCT with fixed tube voltage of 120 kV in combination with filtered back projection reconstruction. The second examination was performed on a third-generation 192-slice DSCT using automated TVA in combination with ADMIRE. Attenuation and image noise of liver, spleen, renal cortex, aorta, vena cava inferior, portal vein, psoas muscle, and perinephric fat were measured. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Radiation dose was assessed as size-specific dose estimates (SSDE). Subjective image quality was assessed by two observers using five-point Likert scales. Interobserver agreement was calculated using intraclass correlation coefficients (ICC). RESULTS Automated TVA set tube voltage to 90 kV (n = 8), 100 kV (n = 31), 110 kV (n = 11), or 120 kV (n = 1). Average SSDE was decreased by 34.9% using 192-slice DSCT compared to 128-slice 120-kV DSCT (7.8 ± 2.4 vs. 12.1 ± 3.2 mGy; P < .001). Image noise was substantially lower; SNR and CNR were significantly increased in 192-slice DSCT compared to 128-slice DSCT (all P < .005). Image quality was voted excellent for both acquisition techniques (5.00 vs. 4.93; P = .083). CONCLUSIONS Automated TVA in combination with ADMIRE on third-generation 192-slice DSCT in portal venous-phase thoracoabdominal CT provides excellent image quality with reduced image noise and increased SNR and CNR, whereas average radiation dose is reduced by 34.9% compared to 128-slice DSCT.
Collapse
|
21
|
Automated Tube Potential Selection as a Method of Dose Reduction for CT of the Neck: First Clinical Results. AJR Am J Roentgenol 2015; 204:1049-54. [PMID: 25905940 DOI: 10.2214/ajr.14.12975] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The objective of our study was to investigate whether the use of a software-based automated tube potential selection (ATPS) CT neck protocol can result in radiation dose reduction as compared with a set 120-kV protocol without a statistically significant reduction in image quality. MATERIALS AND METHODS Three hundred sixty-four patients (median age, 52 years) underwent CT of the neck. Group 1 (n = 320) underwent CT with ATPS with 80, 100, or 120 kV. Group 2 (n = 44) was examined with the standard CT protocol at 120 kV. Attenuation, image background noise, signal-to-noise ratio (SNR), dose-length product (DLP), volume CT dose index (CTDIvol), body mass index (BMI [weight in kilograms divided by the square of height in meters]), and subjective image quality (5-point Likert scale, two readers in consensus) were analyzed. RESULTS A tube potential of 100 kV was selected in 279 patients, 120 kV in 40 patients, and 80 kV in one patient of the ATPS group. A significant correlation was found for selected tube potential and BMI (80 kV, BMI = 20.4; 100 kV, mean BMI = 24.2; 120 kV, BMI = 28.6; r = 0.28, p < 0.01). The average radiation dose was significantly lower with ATPS activated than with the standard protocol (mean DLP, 259 vs 350 mGy × cm, respectively). Background noise did not differ between groups 1 and 2 at the levels of the mandibular angle and the upper mediastinum; however, attenuation and SNR increased significantly with lower tube potential settings. Subjective image quality did not suffer (mean image quality score: ATPS protocol vs standard protocol, 4.56 vs 4.61, respectively; p > 0.05) with good interobserver agreement (κ > 0.56). CONCLUSION ATPS allows significant dose savings for CT of the neck compared with a standard protocol that uses a fixed 120-kV setting without a statistically significant reduction in image quality.
Collapse
|
22
|
Effects of automatic tube potential selection on radiation dose index, image quality, and lesion detectability in pediatric abdominopelvic CT and CTA: a phantom study. Eur Radiol 2015; 26:157-66. [DOI: 10.1007/s00330-015-3817-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2014] [Revised: 04/20/2015] [Accepted: 04/21/2015] [Indexed: 11/26/2022]
|
23
|
Lell MM, May MS, Brand M, Eller A, Buder T, Hofmann E, Uder M, Wuest W. Imaging the Parasinus Region with a Third-Generation Dual-Source CT and the Effect of Tin Filtration on Image Quality and Radiation Dose. AJNR Am J Neuroradiol 2015; 36:1225-30. [PMID: 25814658 DOI: 10.3174/ajnr.a4270] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2014] [Accepted: 12/14/2014] [Indexed: 12/16/2022]
Abstract
BACKGROUND AND PURPOSE CT is the imaging technique of choice in the evaluation of midface trauma or inflammatory disease. We performed a systematic evaluation of scan protocols to optimize image quality and radiation exposure on third-generation dual-source CT. MATERIALS AND METHODS CT protocols with different tube voltage (70-150 kV), current (25-300 reference mAs), prefiltration, pitch value, and rotation time were systematically evaluated. All images were reconstructed with iterative reconstruction (Advanced Modeled Iterative Reconstruction, level 2). To individually compare results with otherwise identical factors, we obtained all scans on a frozen human head. Conebeam CT was performed for image quality and dose comparison with multidetector row CT. Delineation of important anatomic structures and incidental pathologic conditions in the cadaver head was evaluated. RESULTS One hundred kilovolts with tin prefiltration demonstrated the best compromise between dose and image quality. The most dose-effective combination for trauma imaging was Sn100 kV/250 mAs (volume CT dose index, 2.02 mGy), and for preoperative sinus surgery planning, Sn100 kV/150 mAs (volume CT dose index, 1.22 mGy). "Sn" indicates an additional prefiltration of the x-ray beam with a tin filter to constrict the energy spectrum. Exclusion of sinonasal disease was possible with even a lower dose by using Sn100 kV/25 mAs (volume CT dose index, 0.2 mGy). CONCLUSIONS High image quality at very low dose levels can be achieved by using a Sn100-kV protocol with iterative reconstruction. The effective dose is comparable with that of conventional radiography, and the high image quality at even lower radiation exposure favors multidetector row CT over conebeam CT.
Collapse
Affiliation(s)
- M M Lell
- From the Departments of Radiology (M.M.L., M.S.M., M.B., A.E., M.U., W.W.) Imaging Science Institute (M.M.L., M.U.), University Erlangen, Erlangen, Germany.
| | - M S May
- From the Departments of Radiology (M.M.L., M.S.M., M.B., A.E., M.U., W.W.)
| | - M Brand
- From the Departments of Radiology (M.M.L., M.S.M., M.B., A.E., M.U., W.W.)
| | - A Eller
- From the Departments of Radiology (M.M.L., M.S.M., M.B., A.E., M.U., W.W.)
| | - T Buder
- Department I (T.B.), Institute of Anatomy
| | - E Hofmann
- Orthodontics and Orofacial Orthopedics (E.H.)
| | - M Uder
- From the Departments of Radiology (M.M.L., M.S.M., M.B., A.E., M.U., W.W.) Imaging Science Institute (M.M.L., M.U.), University Erlangen, Erlangen, Germany
| | - W Wuest
- From the Departments of Radiology (M.M.L., M.S.M., M.B., A.E., M.U., W.W.)
| |
Collapse
|
24
|
Optimizing Contrast Media Injection Protocols in State-of-the Art Computed Tomographic Angiography. Invest Radiol 2015; 50:161-7. [DOI: 10.1097/rli.0000000000000119] [Citation(s) in RCA: 75] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|
25
|
Recent Technological Advances in Computed Tomography and the Clinical Impact Therein. Invest Radiol 2015; 50:119-27. [DOI: 10.1097/rli.0000000000000125] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
26
|
Song JS, Choi EJ, Kim EY, Kwak HS, Han YM. Attenuation-based automatic kilovoltage selection and sinogram-affirmed iterative reconstruction: effects on radiation exposure and image quality of portal-phase liver CT. Korean J Radiol 2015; 16:69-79. [PMID: 25598675 PMCID: PMC4296279 DOI: 10.3348/kjr.2015.16.1.69] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2013] [Accepted: 10/19/2014] [Indexed: 11/20/2022] Open
Abstract
Objective To compare the radiation dose and image quality between standard-dose CT and a low-dose CT obtained with the combined use of an attenuation-based automatic kilovoltage (kV) selection tool (CARE kV) and sinogram-affirmed iterative reconstruction (SAFIRE) for contrast-enhanced CT examination of the liver. Materials and Methods We retrospectively reviewed 67 patients with chronic liver disease in whom both, standard-dose CT with 64-slice multidetector-row CT (MDCT) (protocol A), and low-dose CT with 128-slice MDCT using CARE kV and SAFIRE (protocol B) were performed. Images from protocol B during the portal phase were reconstructed using either filtered back projection or SAFIRE with 5 different iterative reconstruction (IR) strengths. We performed qualitative and quantitative analyses to select the appropriate IR strength. Reconstructed images were then qualitatively and quantitatively compared with protocol A images. Results Qualitative and quantitative analysis of protocol B demonstrated that SAFIRE level 2 (S2) was most appropriate in our study. Qualitative and quantitative analysis comparing S2 images from protocol B with images from protocol A, showed overall good diagnostic confidence of S2 images despite a significant radiation dose reduction (47% dose reduction, p < 0.001). Conclusion Combined use of CARE kV and SAFIRE allowed significant reduction in radiation exposure while maintaining image quality in contrast-enhanced liver CT.
Collapse
Affiliation(s)
- Ji Soo Song
- Department of Radiology, Chonbuk National University Medical School and Hospital, Biomedical Research Institute of Chonbuk National University Hospital, Jeonju 561-712, Korea
| | - Eun Jung Choi
- Department of Radiology, Chonbuk National University Medical School and Hospital, Biomedical Research Institute of Chonbuk National University Hospital, Jeonju 561-712, Korea
| | - Eun Young Kim
- Department of Radiology, Chonbuk National University Medical School and Hospital, Biomedical Research Institute of Chonbuk National University Hospital, Jeonju 561-712, Korea
| | - Hyo Sung Kwak
- Department of Radiology, Chonbuk National University Medical School and Hospital, Biomedical Research Institute of Chonbuk National University Hospital, Jeonju 561-712, Korea
| | - Young Min Han
- Department of Radiology, Chonbuk National University Medical School and Hospital, Biomedical Research Institute of Chonbuk National University Hospital, Jeonju 561-712, Korea
| |
Collapse
|
27
|
Sun H, Xue HD, Jin ZY, Wang X, Chen Y, He YL, Zhang DM, Zhu L. Non-enhanced Low-tube-voltage High-pitch Dual-source Computed Tomography with Sinogram Affirmed Iterative Reconstruction Algorithm of the Abdomen and Pelvis. ACTA ACUST UNITED AC 2014; 29:214-20. [DOI: 10.1016/s1001-9294(14)60073-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
28
|
Adaptation of contrast injection protocol to tube potential for cardiovascular CT. AJR Am J Roentgenol 2014; 203:1181-91. [PMID: 25415695 DOI: 10.2214/ajr.13.12013] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
OBJECTIVE The purpose of this study was to investigate and validate adaptation of a cardiovascular CT angiography contrast injection protocol for lower tube potential. MATERIALS AND METHODS Eighty-three patients evaluated for thoracic aortic disease with a 256-MDCT scanner were imaged at 120 kV (group 1) or 100 kV (group 2) with the same contrast protocol (90 mL iopromide 370 mg I/mL at 3.5 mL/s). A pharmacokinetic model was validated and used to simulate aortic attenuation in group 2 patients with 20%, 33%, and 44% reduction in contrast volume. A 44% volume reduction was applied to 50 additional patients who underwent imaging at 100 kV (group 3). Patient characteristics, scanning and radiation parameters, and objective and subjective image indexes were compared among groups. RESULTS Group 2 patients had higher mean aortic blood attenuation (399±61 HU) than group 1 patients (281±48 HU) (p<0.001) but similar image noise. Group 3 and group 1 patients had similar mean aortic attenuation and noise. Subjective assessment of image quality indicated that group 3 and group 1 had comparable percentages of images with good or excellent diagnostic confidence scores (reader 1, 98% vs 96%; reader 2, 96% vs 96%). CONCLUSION Lower tube potential (100 kV) for cardiothoracic CT could be accompanied by a 44% reduction in contrast volume with satisfactory aortic blood-pool attenuation in most patients. More personalized adaptation of the contrast protocol that takes into account patient characteristics and tube potential is necessary to ensure sufficient contrast enhancement for all patients.
Collapse
|
29
|
Beeres M, Römer M, Bodelle B, Lee C, Gruber-Rouh T, Mbalisike E, Kerl JM, Wichmann JL, Schulz B, Vogl TJ, Bauer RW. Chest-abdomen-pelvis CT for staging in cancer patients: dose effectiveness and image quality using automated attenuation-based tube potential selection. Cancer Imaging 2014; 14:28. [PMID: 25609222 PMCID: PMC4331833 DOI: 10.1186/s40644-014-0028-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2014] [Accepted: 08/18/2014] [Indexed: 11/25/2022] Open
Abstract
Background Evaluation of automated attenuation-based tube potential selection and its impact on image quality and radiation dose in CT (computed tomography) examinations for cancer staging. Methods A total of 110 (59 men, 51 women) patients underwent chest-abdomen-pelvis CT examinations; 55 using a fixed tube potential of 120 kV/current of 210 Reference mAs (using CareDose4D), and 55 using automated attenuation-based tube potential selection (CAREkV) also using a current of 210 Reference mAs. This evaluation was performed as a single-centre, observer-blinded retrospective analysis. Image quality was assessed by two readers in consensus. Attenuation, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured or calculated for objective image evaluation. For the evaluation of radiation exposure, dose-length-product (DLP) values were compared and Size-specific dose estimates (SSDE) values were calculated. Results Diagnostic image quality was obtained from all patients. The median DLP (703.5 mGy · cm, range 390–2203 mGy · cm) was 7.9% lower when using the algorithm compared with the standard 120 kV protocol (median 756 mGy · cm, range 345–2267 mGy · cm). A reduction in potential to 100 kV occurred in 32 cases; therefore, these patients received significantly lower radiation exposure compared with the 120 kV protocol. Conclusion Automated attenuation-based tube potential selection produces good diagnostic image quality in chest-abdomen-pelvis CT and reduces the patient’s overall radiation dose by 7.9% compared to the standard 120 kV protocol.
Collapse
|
30
|
Boos J, Kröpil P, Klee D, Heusch P, Schimmöller L, Schaper J, Antoch G, Lanzman RS. Evaluation of the impact of organ-specific dose reduction on image quality in pediatric chest computed tomography. Pediatr Radiol 2014; 44:1065-9. [PMID: 25022489 DOI: 10.1007/s00247-014-2950-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2013] [Revised: 02/18/2014] [Accepted: 02/26/2014] [Indexed: 10/25/2022]
Abstract
BACKGROUND Organ-specific dose reduction significantly reduces the radiation exposure of radiosensitive organs. OBJECTIVE The purpose of this study was to assess the impact of a novel organ-specific dose reduction algorithm on image quality of pediatric chest CT. MATERIALS AND METHODS We included 28 children (mean age 10.9 ± 4.8 years, range 3-18 years) who had contrast-enhanced chest CT on a 128-row scanner. CT was performed at 100 kV using automated tube current modulation and a novel organ-specific dose-reduction algorithm (XCare™; Siemens, Forchheim, Germany). Seven children had a previous chest CT performed on a 64-row scanner at 100 kV without organ-specific dose reduction. Subjective image quality was assessed using a five-point scale (1-not diagnostic; 5-excellent). Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were assessed in the descending aorta. RESULTS Overall mean subjective image quality was 4.1 ± 0.6. In the subgroup of the seven children examined both with and without organ-specific dose reduction, subjective image quality was comparable (score 4.4 ± 0.5 with organ-specific dose reduction vs. 4.4 ± 0.7 without it; P > 0.05). There was no significant difference in mean signal-to-noise ratio and contrast-to-noise ratio with organ-specific dose reduction (38.3 ± 10.1 and 28.5 ± 8.7, respectively) and without the reduction (35.5 ± 8.5 and 26.5 ± 7.8, respectively) (P > 0.05). Volume computed tomography dose index (CTDIvol) and size-specific dose estimates did not differ significantly between acquisitions with the organ-specific dose reduction (1.7 ± 0.8 mGy) and without the reduction (1.7 ± 0.8 mGy) (P > 0.05). CONCLUSION Organ-specific dose reduction does not have an impact on image quality of pediatric chest CT and can therefore be used in clinical practice to reduce radiation dose of radiosensitive organs such as breast and thyroid gland.
Collapse
Affiliation(s)
- Johannes Boos
- Department of Diagnostic and Interventional Radiology, University Dusseldorf, Medical Faculty, D-40225, Dusseldorf, Germany
| | | | | | | | | | | | | | | |
Collapse
|
31
|
Fuentes-Orrego JM, Pinho D, Kulkarni NM, Agrawal M, Ghoshhajra BB, Sahani DV. New and Evolving Concepts in CT for Abdominal Vascular Imaging. Radiographics 2014; 34:1363-1384. [DOI: 10.1148/rg.345130070] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/30/2023]
|
32
|
Potential for Radiation Dose Savings in Abdominal and Chest CT Using Automatic Tube Voltage Selection in Combination With Automatic Tube Current Modulation. AJR Am J Roentgenol 2014; 203:292-9. [DOI: 10.2214/ajr.13.11628] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
33
|
Krazinski AW, Meinel FG, Schoepf UJ, Silverman JR, Canstein C, De Cecco CN, Geyer LL. Reduced radiation dose and improved image quality at cardiovascular CT angiography by automated attenuation-based tube voltage selection: intra-individual comparison. Eur Radiol 2014; 24:2677-84. [PMID: 25052076 DOI: 10.1007/s00330-014-3312-9] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2014] [Revised: 05/14/2014] [Accepted: 07/03/2014] [Indexed: 11/27/2022]
Abstract
OBJECTIVES To evaluate the effect of automated tube voltage selection on radiation dose and image quality at cardiovascular CT angiography (CTA). METHODS We retrospectively analysed paired studies in 72 patients (41 male, 60.5 ± 16.5 years), who had undergone CTA acquisitions of the heart or aorta both before and after the implementation of an automated x-ray tube voltage selection algorithm (ATVS). All other parameters were kept identical between the two acquisitions. Subjective image quality (IQ) was rated and objective IQ was measured by image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and figure of merit (FOM). Image quality parameters and effective dose were compared between acquisitions. RESULTS Overall subjective image quality improved with the percentage of cases scored as adequate or higher increasing from 79 % to 92 % after implementation of ATVS (P = 0.03). SNR (14.1 ± 5.9, 15.7 ± 6.1, P = 0.009), CNR (11.6 ± 5.3, 13.2 ± 5.6, P = 0.011), and FOM (19.9 ± 23.3, 43.8 ± 51.1, P < 0.001) were significantly higher after implementation of ATVS. Mean image noise (24.1 ± 8.4 HU, 22.7 ± 7.1 HU, P = 0.048) and mean effective dose (10.6 ± 5.9 mSv, 8.8 ± 5.0 mSv, P = 0.003) were significantly lower after implementation of ATVS. CONCLUSIONS Automated tube voltage selection can operator-independently optimize cardiovascular CTA image acquisition parameters with improved image quality at reduced dose. KEY POINTS • Automatic tube voltage selection optimizes tube voltage for each individual patient. • In this population, overall radiation dose decreased while image quality improved. • This tool may become valuable for improving dose/quality ratio.
Collapse
Affiliation(s)
- Aleksander W Krazinski
- Department of Radiology and Radiological Science, Medical University of South Carolina, Ashley River Tower, MSC 226 25 Courtenay Drive, Charleston, SC, 29425, USA
| | | | | | | | | | | | | |
Collapse
|
34
|
May MS, Kramer MR, Eller A, Wuest W, Scharf M, Brand M, Saake M, Schmidt B, Uder M, Lell MM. Automated tube voltage adaptation in head and neck computed tomography between 120 and 100 kV: effects on image quality and radiation dose. Neuroradiology 2014; 56:797-803. [DOI: 10.1007/s00234-014-1393-4] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2014] [Accepted: 06/11/2014] [Indexed: 01/02/2023]
|
35
|
Kulkarni NM, Pinho DF, Kambadakone AR, Sahani DV. Emerging technologies in CT- radiation dose reduction and dual-energy CT. Semin Roentgenol 2014; 48:192-202. [PMID: 23796370 DOI: 10.1053/j.ro.2013.03.007] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Affiliation(s)
- Naveen M Kulkarni
- Massachusetts General Hospital, Division of Abdominal Imaging and Intervention, Boston, MA 02114, USA
| | | | | | | |
Collapse
|
36
|
MDCT of Chest, Abdomen, and Pelvis Using Attenuation-Based Automated Tube Voltage Selection in Combination With Iterative Reconstruction: An Intrapatient Study of Radiation Dose and Image Quality. AJR Am J Roentgenol 2013; 201:1075-82. [DOI: 10.2214/ajr.12.10354] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
37
|
Combining automated attenuation-based tube voltage selection and iterative reconstruction: a liver phantom study. Eur Radiol 2013; 24:657-67. [DOI: 10.1007/s00330-013-3049-x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2013] [Revised: 09/27/2013] [Accepted: 10/04/2013] [Indexed: 10/26/2022]
|
38
|
Automated attenuation-based selection of tube voltage and tube current for coronary CT angiography: reduction of radiation exposure versus a BMI-based strategy with an expert investigator. J Cardiovasc Comput Tomogr 2013; 7:303-10. [PMID: 24268117 DOI: 10.1016/j.jcct.2013.08.010] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/29/2013] [Revised: 06/29/2013] [Accepted: 08/16/2013] [Indexed: 11/24/2022]
Abstract
BACKGROUND Recently developed automated algorithms use the topogram and the corresponding attenuation information before coronary CT angiography (CTA) to allow for an individualized anatomic-based selection of tube current (mAs) and voltage (kV). OBJECTIVES The value of these algorithms in reducing the associated radiation exposure was evaluated. METHODS One hundred patients underwent coronary CTA with dual-source CT with prospectively electrocardiogram-triggered axial data acquisition. In all patients, tube parameters (current and voltage) were suggested by both an experienced investigator according to the patient's body mass index (BMI; calculated as weight divided by height squared; kg/m(2)) and by an automated software according to attenuation values of the initial topogram. The first 50 consecutive patients (group 1) underwent coronary CTA with dual-source CT with tube parameters suggested by the experienced investigator (BMI-based tube parameters), whereas in another 50 consecutive patients (group 2) CT data acquisition was performed with tube settings of the automated software. Subsequently, subjective image quality (4-point rating score from 0 = nondiagnostic to 3 = excellent image quality), image noise (SD of CT number within the aortic root), as well as signal- and contrast-to-noise ratios and mean effective radiation doses, were compared between both groups. RESULTS Both groups showed comparable image quality parameters (group 1 vs 2: noise, 28.1 ± 6.0 HU vs 29.9 ± 5.4 HU, P = .12; signal-to-noise ratio, 16.4 ± 3.9 vs 16.8 ± 4.1, P = .54; contrast-to-noise ratio, 18.6 ± 4.1 vs 19.2 ± 4.3, P = .49; 4-point rating score, 2.8 ± 0.3 vs 2.9 ± 0.3, P = .81). Tube voltage, current, and mean effective radiation dose for groups 1 and 2 were 111 ± 12 kV and 108 ± 12 kV (P = .18), 361 ± 32 mAs and 320 ± 48 mAs (P < .001), and 2.3 mSv (25th; 75th percentile, 1.5; 2.8 mSv) and 1.4 mSv (25th; 75th percentile, 1.1; 1.9 mSv) (P < .001), respectively. CONCLUSIONS Automated attenuation-based selections of individualized tube parameters are superior to BMI-based selections with expert oversight and show a potential for reduction of radiation exposure in coronary CTA, and image quality is maintained.
Collapse
|
39
|
Eller A, Wuest W, Scharf M, Brand M, Achenbach S, Uder M, Lell MM. Attenuation-based automatic kilovolt (kV)-selection in computed tomography of the chest: effects on radiation exposure and image quality. Eur J Radiol 2013; 82:2386-91. [PMID: 24050878 DOI: 10.1016/j.ejrad.2013.08.043] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2013] [Revised: 08/12/2013] [Accepted: 08/17/2013] [Indexed: 12/17/2022]
Abstract
OBJECTIVES To evaluate an automated attenuation-based kV-selection in computed tomography of the chest in respect to radiation dose and image quality, compared to a standard 120 kV protocol. MATERIALS AND METHODS 104 patients were examined using a 128-slice scanner. Fifty examinations (58 ± 15 years, study group) were performed using the automated adaption of tube potential (100-140 kV), based on the attenuation profile of the scout scan, 54 examinations (62 ± 14 years, control group) with fixed 120 kV. Estimated CT dose index (CTDI) of the software-proposed setting was compared with a 120 kV protocol. After the scan CTDI volume (CTDIvol) and dose length product (DLP) were recorded. Image quality was assessed by region of interest (ROI) measurements, subjective image quality by two observers with a 4-point scale (3--excellent, 0--not diagnostic). RESULTS The algorithm selected 100 kV in 78% and 120 kV in 22%. Overall CTDIvol reduction was 26.6% (34% in 100 kV) overall DLP reduction was 22.8% (32.1% in 100 kV) (all p<0.001). Subjective image quality was excellent in both groups. CONCLUSION The attenuation based kV-selection algorithm enables relevant dose reduction (~27%) in chest-CT while keeping image quality parameters at high levels.
Collapse
Affiliation(s)
- Achim Eller
- Department of Radiology, University Erlangen, Germany
| | | | | | | | | | | | | |
Collapse
|
40
|
|
41
|
Eller A, Wuest W, Kramer M, May M, Schmid A, Uder M, Lell MM. Carotid CTA: radiation exposure and image quality with the use of attenuation-based, automated kilovolt selection. AJNR Am J Neuroradiol 2013; 35:237-41. [PMID: 23907241 DOI: 10.3174/ajnr.a3659] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
BACKGROUND AND PURPOSE CTA is considered the imaging modality of choice in evaluating the supraaortic vessels in many institutions, but radiation exposure remains a matter of concern. The objective of the study was to evaluate a fully automated, attenuation-based kilovolt selection algorithm in carotid CTA in respect to radiation dose and image quality compared with a standard 120-kV protocol. MATERIALS AND METHODS Ninety-eight patients were included: 53 examinations (patient age, 66 ± 12 years) were performed by use of automated adaption of tube potential (80-140 kV) on the basis of the attenuation profile of the scout scan (study group), and 45 examinations (patient age, 67 ± 11 years) were performed by use of a standard 120-kV protocol (control group). CT dose index volume and dose-length product were recorded from the examination protocol. Image quality was assessed by ROI measurements and calculations of SNR and contrast-to-noise ratio. Subjective image quality was evaluated by 2 observers with the use of a 4-point scale (3, excellent; 0, not diagnostic). RESULTS Subjective image quality was rated as "excellent" or "good" in all examinations (study group, 2.8; control group, 2.8). The algorithm automatically selected 100 kV in 47% and 80 kV in 34%; 120 kV was retained in 19%. An elevation to 140 kV did not occur. Compared with the control group, overall CT dose index volume reduction was 33.7%; overall dose-length product reduction was 31.5%. In the low-kilovolt scans, image noise and mean attenuation of ROIs inside the carotid arteries were significantly higher than in 120-kV scans, resulting in a constant or increased (80-kV group) contrast-to-noise ratio. CONCLUSIONS The attenuation-based, kilovolt selection algorithm enables a dose reduction of >30% in carotid artery CTA while maintaining contrast-to-noise ratio and subjective image quality at adequate levels.
Collapse
Affiliation(s)
- A Eller
- From the Department of Radiology, University Erlangen, Erlangen, Germany
| | | | | | | | | | | | | |
Collapse
|
42
|
May MS, Wuest W, Lell MM, Uder M, Kalender WA, Schmidt B. [Current strategies for dosage reduction in computed tomography]. Radiologe 2013; 52:905-13. [PMID: 22914872 DOI: 10.1007/s00117-012-2338-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
The potential risks of radiation exposure associated with computed tomography (CT) imaging are reason for ongoing concern for both medical staff and patients. Radiation dose reduction is, according to the as low as reasonably achievable principle, an important issue in clinical routine, research and development. The complex interaction of preparation, examination and post-processing provides a high potential for optimization on the one hand but on the other a high risk for errors. The radiologist is responsible for the quality of the CT examination which requires specialized and up-to-date knowledge. Most of the techniques for radiation dose reduction are independent of the system and manufacturer. The basic principle should be radiation dose optimization without loss of diagnostic image quality rather than just reduction.