1
|
Li F, Liu R, Li W, Xie M, Qin S. Synchrotron Radiation: A Key Tool for Drug Discovery. Bioorg Med Chem Lett 2024; 114:129990. [PMID: 39406298 DOI: 10.1016/j.bmcl.2024.129990] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2024] [Revised: 09/22/2024] [Accepted: 10/11/2024] [Indexed: 10/25/2024]
Abstract
Synchrotron radiation is extensively utilized in the domains of materials science, physical chemistry, and life science, resulting from its high intensity, exceptional monochromaticity, superior collimation, and broad wave spectrum. This top-notch light source has also made significant contributions to the progress of biomedicine. The advancement of synchrotron radiation-based X-ray and protein crystallography technologies has created new prospects for drug discovery. These innovative techniques have opened up exciting avenues in the field. The investigation of protein crystal structures and the elucidation of the spatial configuration of biological macromolecules have revealed intricate details regarding the modes of protein binding. Furthermore, the screening of crystal polymorphs and ligands has laid the groundwork for rational drug modification and the improvement of drug physicochemical properties. As science and technology continue to advance, the techniques for analyzing structures using synchrotron radiation sources and the design of corresponding crystallographic beamline stations are undergoing continuous enhancement. These cutting-edge tools and facilities are expected to expedite the drug development process and rectify the current situation of a lack of targeted drugs.
Collapse
Affiliation(s)
- Fengcheng Li
- Qingdao Academy of Chinese Medical Sciences, Shandong University of Traditional Chinese Medicine, Qingdao 266112, China; Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China
| | - Runze Liu
- Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China
| | - Wenjun Li
- Qingdao Academy of Chinese Medical Sciences, Shandong University of Traditional Chinese Medicine, Qingdao 266112, China; Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China
| | - Mingyuan Xie
- Institute of Advanced Science Facilities, Shenzhen, Guangdong 518107, China.
| | - Song Qin
- Qingdao Academy of Chinese Medical Sciences, Shandong University of Traditional Chinese Medicine, Qingdao 266112, China; Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China.
| |
Collapse
|
2
|
Kabanova V, Sander M, Levantino M, Kong Q, Canton S, Retegan M, Cammarata M, Lenzen P, Lawson LMD, Wulff M. Structure and spin of the low- and high-spin states of Fe 2+(phen) 3 studied by x-ray scattering and emission spectroscopy. STRUCTURAL DYNAMICS (MELVILLE, N.Y.) 2024; 11:054901. [PMID: 39449690 PMCID: PMC11501788 DOI: 10.1063/4.0000254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/24/2024] [Accepted: 10/03/2024] [Indexed: 10/26/2024]
Abstract
The structure and spin of photoexcited Fe2+(phen)3 in water are examined by x-ray scattering and x-ray emission spectroscopy with 100 ps time resolution. Excitation of the low-spin (LS) ground state (GS) to the charge transfer state 1MLCT* leads to the formation of a high-spin (HS) state that returns to the GS in 725 ps. Density functional theory (DFT) predicts a Fe-N bond elongation in HS by 0.19 Å in agreement with the scattering data. The angle between the ligands increases by 5.4° in HS, which allows the solvent to get 0.33 Å closer to Fe in spite of the expansion of the molecule. The rise in solvent temperature from the return of photoproducts to the GS is dominated by the formation dynamics of HS, 1MLCT* → HS, which is followed by a smaller rise from the HS → GS transition. The latter agrees with the 0.61 eV energy gap E(HS)-E(LS) calculated by DFT. However, the temperature rise from the 1MLCT → HS transition is greater than expected, by a factor of 2.1, which is explained by the re-excitation of nascent HS* by the 1.2 ps pump pulse. This hypothesis is supported by optical spectroscopy measurements showing that the 1.2 ps long pump pulse activates the HS* → 5MLCT* channel, which is followed by the ultrafast return to HS* via intersystem crossing. Finally, the spins of the photoproducts are monitored by the Kβ emission and the spectra confirm that the spins of LS and HS states are 0 and 2, respectively.
Collapse
Affiliation(s)
| | | | - Matteo Levantino
- European Synchrotron Radiation Facility, CS 40220 Grenoble Cédex 9, France
| | - Qingyu Kong
- Synchrotron Soleil, L'Orme des Merisiers, 91190 Saint-Aubin, France
| | | | - Marius Retegan
- European Synchrotron Radiation Facility, CS 40220 Grenoble Cédex 9, France
| | - Marco Cammarata
- European Synchrotron Radiation Facility, CS 40220 Grenoble Cédex 9, France
| | - Philipp Lenzen
- SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | | | - Michael Wulff
- European Synchrotron Radiation Facility, CS 40220 Grenoble Cédex 9, France
| |
Collapse
|
3
|
Warias JE, Petersdorf L, Hövelmann SC, Giri RP, Lemke C, Festersen S, Greve M, Mandin P, LeBideau D, Bertram F, Magnussen OM, Murphy BM. The laser pump X-ray probe system at LISA P08 PETRA III. JOURNAL OF SYNCHROTRON RADIATION 2024; 31:779-790. [PMID: 38843001 PMCID: PMC11226150 DOI: 10.1107/s1600577524003400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Accepted: 04/17/2024] [Indexed: 07/06/2024]
Abstract
Understanding and controlling the structure and function of liquid interfaces is a constant challenge in biology, nanoscience and nanotechnology, with applications ranging from molecular electronics to controlled drug release. X-ray reflectivity and grazing incidence diffraction provide invaluable probes for studying the atomic scale structure at liquid-air interfaces. The new time-resolved laser system at the LISA liquid diffractometer situated at beamline P08 at the PETRA III synchrotron radiation source in Hamburg provides a laser pump with X-ray probe. The femtosecond laser combined with the LISA diffractometer allows unique opportunities to investigate photo-induced structural changes at liquid interfaces on the pico- and nanosecond time scales with pump-probe techniques. A time resolution of 38 ps has been achieved and verified with Bi. First experiments include laser-induced effects on salt solutions and liquid mercury surfaces with static and varied time scales measurements showing the proof of concept for investigations at liquid surfaces.
Collapse
Affiliation(s)
- Jonas Erik Warias
- Institute of Experimental and Applied PhysicsKiel UniversityLeibnizstrasse 1924118KielGermany
| | - Lukas Petersdorf
- Institute of Experimental and Applied PhysicsKiel UniversityLeibnizstrasse 1924118KielGermany
- Ruprecht-Haensel Laboratory, Olshausenstrasse 40, 24098Kiel, Germany
| | - Svenja Carolin Hövelmann
- Institute of Experimental and Applied PhysicsKiel UniversityLeibnizstrasse 1924118KielGermany
- Ruprecht-Haensel Laboratory, Olshausenstrasse 40, 24098Kiel, Germany
- Deutsches Elektronen-Synchrotron DESYNotkestrasse 8522607HamburgGermany
| | - Rajendra Prasad Giri
- Institute of Experimental and Applied PhysicsKiel UniversityLeibnizstrasse 1924118KielGermany
| | - Christoph Lemke
- Institute of Experimental and Applied PhysicsKiel UniversityLeibnizstrasse 1924118KielGermany
| | - Sven Festersen
- Institute of Experimental and Applied PhysicsKiel UniversityLeibnizstrasse 1924118KielGermany
| | - Matthias Greve
- Institute of Experimental and Applied PhysicsKiel UniversityLeibnizstrasse 1924118KielGermany
| | | | | | - Florian Bertram
- Deutsches Elektronen-Synchrotron DESYNotkestrasse 8522607HamburgGermany
| | - Olaf Magnus Magnussen
- Institute of Experimental and Applied PhysicsKiel UniversityLeibnizstrasse 1924118KielGermany
- Ruprecht-Haensel Laboratory, Olshausenstrasse 40, 24098Kiel, Germany
| | - Bridget Mary Murphy
- Institute of Experimental and Applied PhysicsKiel UniversityLeibnizstrasse 1924118KielGermany
- Ruprecht-Haensel Laboratory, Olshausenstrasse 40, 24098Kiel, Germany
| |
Collapse
|
4
|
Reinhard M, Skoien D, Spies JA, Garcia-Esparza AT, Matson BD, Corbett J, Tian K, Safranek J, Granados E, Strader M, Gaffney KJ, Alonso-Mori R, Kroll T, Sokaras D. Solution phase high repetition rate laser pump x-ray probe picosecond hard x-ray spectroscopy at the Stanford Synchrotron Radiation Lightsource. STRUCTURAL DYNAMICS (MELVILLE, N.Y.) 2023; 10:054304. [PMID: 37901682 PMCID: PMC10613086 DOI: 10.1063/4.0000207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Accepted: 10/11/2023] [Indexed: 10/31/2023]
Abstract
We present a dedicated end-station for solution phase high repetition rate (MHz) picosecond hard x-ray spectroscopy at beamline 15-2 of the Stanford Synchrotron Radiation Lightsource. A high-power ultrafast ytterbium-doped fiber laser is used to photoexcite the samples at a repetition rate of 640 kHz, while the data acquisition operates at the 1.28 MHz repetition rate of the storage ring recording data in an alternating on-off mode. The time-resolved x-ray measurements are enabled via gating the x-ray detectors with the 20 mA/70 ps camshaft bunch of SPEAR3, a mode available during the routine operations of the Stanford Synchrotron Radiation Lightsource. As a benchmark study, aiming to demonstrate the advantageous capabilities of this end-station, we have conducted picosecond Fe K-edge x-ray absorption spectroscopy on aqueous [FeII(phen)3]2+, a prototypical spin crossover complex that undergoes light-induced excited spin state trapping forming an electronic excited state with a 0.6-0.7 ns lifetime. In addition, we report transient Fe Kβ main line and valence-to-core x-ray emission spectra, showing a unique detection sensitivity and an excellent agreement with model spectra and density functional theory calculations, respectively. Notably, the achieved signal-to-noise ratio, the overall performance, and the routine availability of the developed end-station have enabled a systematic time-resolved science program using the monochromatic beam at the Stanford Synchrotron Radiation Lightsource.
Collapse
Affiliation(s)
- Marco Reinhard
- SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | - Dean Skoien
- SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | | | | | | | - Jeff Corbett
- SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | - Kai Tian
- SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | - James Safranek
- SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | - Eduardo Granados
- SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | - Matthew Strader
- SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | - Kelly J. Gaffney
- SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | | | - Thomas Kroll
- SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | | |
Collapse
|
5
|
Shen X, Wu D, Zhang H, Liu X, Cao L, Yao T. Application of Time-Resolved Synchrotron X-ray Absorption Spectroscopy in an Energy Conversion Reaction. J Phys Chem Lett 2023; 14:645-652. [PMID: 36637141 DOI: 10.1021/acs.jpclett.2c03433] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
The rational design of high-efficiency catalysts is hindered by the knowledge of active sites, which always experience dynamic transformations within different time scales. In this regard, tracking these time-dependent processes is essential to building the correlation between the active site and catalytic performance. Achieving this goal requires powerful characterization techniques to overcome the obstacle induced by the time mismatch. By virtue of the local structure sensitivity, synchrotron X-ray absorption spectroscopy (XAS) comprising step-scanning XAS, quick-scanning XAS, and energy-dispersive XAS has been widely applied to record structural evolution events. In this Perspective, we highlight the substantial accomplishments achieved by these time-resolved XAS techniques. Their principles, advantages, and limitations involved in monitoring energy-involving electrocatalysis were also introduced. Meanwhile, the key challenges that we are encountering and the further directions of time-resolved XAS are also provided. We sincerely hope that these insights could offer a reliable guideline for other researchers to design more efficient in situ experiments.
Collapse
Affiliation(s)
- Xinyi Shen
- National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China
| | - Dan Wu
- National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China
| | - Huijuan Zhang
- National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China
| | - Xiaokang Liu
- National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China
| | - Linlin Cao
- National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China
| | - Tao Yao
- National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China
| |
Collapse
|
6
|
Kinigstein ED, Jennings G, Kurtz CA, March AM, Zuo X, Chen LX, Attenkofer K, Zhang X. X-ray multi-probe data acquisition: A novel technique for laser pump x-ray transient absorption spectroscopy. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:085109. [PMID: 34470434 DOI: 10.1063/5.0050713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Accepted: 08/09/2021] [Indexed: 06/13/2023]
Abstract
We report the development and implementation of a novel data acquisition (DAQ) technique for synchrotron-based laser pump X-ray Transient Absorption (XTA) spectroscopy, called X-ray Multi-Probe DAQ (XMP DAQ). This technique utilizes high performance analog to digital converters and home-built software to efficiently measure and process the XTA signal from all x-ray pulses between laser excitations. XMP DAQ generates a set of time resolved x-ray absorption spectra at thousands of different pump-probe time delays simultaneously. Two distinct XMP DAQ schemes are deployed to accommodate different synchrotron storage ring filling patterns. Current Integration (CI) DAQ is a quasi-analog technique that implements a fitting procedure to extract the time resolved absorption intensity from the averaged fluorescence detector response. The fitting procedure eliminates issues associated with small drifts in the voltage baseline and greatly enhances the accuracy of the technique. Photon Counting (PC) DAQ is a binary technique that uses a time resolved histogram to calculate the XTA spectrum. While PC DAQ is suited to measure XTA data with closely spaced x-ray pulses (∼10 ns) and a low count rate (<1 detected photon/pulse), CI DAQ works best for widely spaced pulses (tens of ns or greater) with a high count rate (>1 detected photon/pulse). XMP DAQ produces a two-dimensional XTA dataset, enabling efficient quantitative analysis of photophysical and photochemical processes from the sub-nanosecond timescale to 100 μs and longer.
Collapse
Affiliation(s)
- Eli D Kinigstein
- X-ray Sciences Division, Argonne National Laboratory, Lemont, Illinois 60439, USA
| | - Guy Jennings
- X-ray Sciences Division, Argonne National Laboratory, Lemont, Illinois 60439, USA
| | - Charles A Kurtz
- X-ray Sciences Division, Argonne National Laboratory, Lemont, Illinois 60439, USA
| | - Anne Marie March
- Chemical Sciences and Engineering Division, Argonne National Laboratory, Argonne, Illinois 60439, USA
| | - Xiaobing Zuo
- X-ray Sciences Division, Argonne National Laboratory, Lemont, Illinois 60439, USA
| | - Lin X Chen
- Chemical Sciences and Engineering Division, Argonne National Laboratory, Argonne, Illinois 60439, USA
| | - Klaus Attenkofer
- Experimental Division, ALBA Synchrotron Light Source, Carrer de la Llum 2-26, Cerdanyola del Vallès, Barcelona 08290, Spain
| | - Xiaoyi Zhang
- X-ray Sciences Division, Argonne National Laboratory, Lemont, Illinois 60439, USA
| |
Collapse
|
7
|
Potemkin FV, Mareev EI, Garmatina AA, Nazarov MM, Fomin EA, Stirin AI, Korchuganov VN, Kvardakov VV, Gordienko VM, Panchenko VY, Kovalchuk MM. Hybrid x-ray laser-plasma/laser-synchrotron facility for pump-probe studies of the extreme state of matter at NRC "Kurchatov Institute". THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:053101. [PMID: 34243278 DOI: 10.1063/5.0028228] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Accepted: 04/17/2021] [Indexed: 06/13/2023]
Abstract
We developed a hybrid optical pump-x-ray probe facility based on the "Kurchatov's synchrotron radiation source" and terawatt (TW) femtosecond laser. The bright x-ray photon source is based on either synchrotron radiation [up to 6 × 1014 photons/(s mm2 mrad2 0.1% bandwidth)] or laser-plasma generators (up to 108 photons/sr/pulse). The terawatt (TW) femtosecond laser pulse initiated phase transitions and a non-stationary "extreme" state of matter, while the delayed x-ray pulse acts as a probe. The synchronization between synchrotron radiation and laser pulses is achieved at 60.3 MHz using an intelligent field-programmable gate array-based phased locked loop. The timing jitter of the system is less than 30 ps. In laser-plasma sources, the x-ray and laser pulses are automatically synchronized because they are produced by using the same laser source (TW laser system). We have reached an x-ray yield of about 106 photons/sr/pulse with 6-mJ sub-ps laser pulses and using helium as a local gas medium. Under vacuum conditions, the laser energy increase up to 40 mJ leads to the enhancement of the x-ray yield of up to 108 photons/sr/pulse. The developed hybrid facility paves the way for a new class of time-resolved x-ray optical pump-probe experiments in the time interval from femtoseconds to microseconds and the energy spectrum from 3 to 30 keV.
Collapse
Affiliation(s)
- Fedor V Potemkin
- Faculty of Physics and International Laser Center, M. V. Lomonosov Moscow State University, Moscow 119991, Russia
| | - Evgeny I Mareev
- Faculty of Physics and International Laser Center, M. V. Lomonosov Moscow State University, Moscow 119991, Russia
| | - Alena A Garmatina
- Institute of Photonic Technologies, FSKC "Crystallography and Photonics," Russian Academy of Sciences, Troitsk 119333, Russia
| | - Maxim M Nazarov
- National Research Centre "Kurchatov Institute," Moscow 123182, Russia
| | - Evgeniy A Fomin
- National Research Centre "Kurchatov Institute," Moscow 123182, Russia
| | | | | | | | - Viacheslav M Gordienko
- Faculty of Physics and International Laser Center, M. V. Lomonosov Moscow State University, Moscow 119991, Russia
| | - Vladislav Ya Panchenko
- Institute of Photonic Technologies, FSKC "Crystallography and Photonics," Russian Academy of Sciences, Troitsk 119333, Russia
| | | |
Collapse
|
8
|
Clark AH, Steiger P, Bornmann B, Hitz S, Frahm R, Ferri D, Nachtegaal M. Fluorescence-detected quick-scanning X-ray absorption spectroscopy. JOURNAL OF SYNCHROTRON RADIATION 2020; 27:681-688. [PMID: 32381768 PMCID: PMC7285694 DOI: 10.1107/s1600577520002350] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2019] [Accepted: 02/19/2020] [Indexed: 06/01/2023]
Abstract
Time-resolved X-ray absorption spectroscopy (XAS) offers the possibility to monitor the state of materials during chemical reactions. While this technique has been established for transmission measurements for a number of years, XAS measurements in fluorescence mode are challenging because of limitations in signal collection as well as detectors. Nevertheless, measurements in fluorescence mode are often the only option to study complex materials containing heavy matrices or in samples where the element of interest is in low concentration. Here, it has been demonstrated that high-quality quick-scanning full extended X-ray absorption fine-structure data can be readily obtained with sub-second time resolution in fluorescence mode, even for highly diluted samples. It has also been demonstrated that in challenging samples, where transmission measurements are not feasible, quick fluorescence can yield significant insight in reaction kinetics. By studying the fast high-temperature oxidation of a reduced LaFe0.8Ni0.8O3 perovskite type, an example where the perovskite matrix elements prevent measurements in fluorescence, it is shown that it is now possible to follow the state of Ni in situ at a 3 s time resolution.
Collapse
Affiliation(s)
- Adam H. Clark
- Paul Scherrer Institut, CH-5232 Villigen, Switzerland
| | | | | | - Stephan Hitz
- Paul Scherrer Institut, CH-5232 Villigen, Switzerland
| | - Ronald Frahm
- Bergische Universität Wuppertal, D-42119 Wuppertal, Germany
| | - Davide Ferri
- Paul Scherrer Institut, CH-5232 Villigen, Switzerland
| | | |
Collapse
|
9
|
Hu Y, Zhan F, Wang Q, Sun Y, Yu C, Zhao X, Wang H, Long R, Zhang G, Gao C, Zhang W, Jiang J, Tao Y, Xiong Y. Tracking Mechanistic Pathway of Photocatalytic CO 2 Reaction at Ni Sites Using Operando, Time-Resolved Spectroscopy. J Am Chem Soc 2020; 142:5618-5626. [PMID: 32130002 DOI: 10.1021/jacs.9b12443] [Citation(s) in RCA: 88] [Impact Index Per Article: 17.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Harvesting solar energy for catalytic conversion of CO2 into valuable chemical fuels/feedstocks is an attractive yet challenging strategy to realize a sustainable carbon-cycle utilization. Homogeneous catalysts typically exhibit higher activity and selectivity as compared with heterogeneous counterparts, benefiting from their atomically dispersed catalytic sites and versatile coordination structures. However, it is still a "black box" how the coordination and electronic structures of catalysts dynamically evolve during the reaction, forming the bottleneck for understanding their reaction pathways. Herein, we demonstrate to track the mechanistic pathway of photocatalytic CO2 reduction using a terpyridine nickel(II) complex as a catalyst model. Integrated with a typical homogeneous photosensitizer, the catalytic system offers a high selectivity of 99% for CO2-to-CO conversion with turnover number and turnover frequency as high as 2.36 × 107 and 385.6 s-1, respectively. We employ operando and time-resolved X-ray absorption spectroscopy, in combination with other in situ spectroscopic techniques and theoretical computations, to track the intermediate species of Ni catalyst in the photocatalytic CO2 reduction reaction for the first time. Taken together with the charge dynamics resolved by optical transient absorption spectroscopy, the investigation elucidates the full mechanistic reaction pathway including some key factors that have been often overlooked. This work opens the "black box" for CO2 reduction in the system of homogeneous catalysts and provides key information for developing efficient catalysts toward artificial photosynthesis.
Collapse
Affiliation(s)
- Yangguang Hu
- Hefei National Laboratory for Physical Sciences at the Microscale, iChEM, School of Chemistry and Materials Science, and National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui 230026, China
| | - Fei Zhan
- Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.,Chemistry and Chemical Engineering Guangdong Laboratory, Shantou, Guangdong 515031, China
| | - Qian Wang
- Hefei National Laboratory for Physical Sciences at the Microscale, iChEM, School of Chemistry and Materials Science, and National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui 230026, China
| | - Yujian Sun
- Hefei National Laboratory for Physical Sciences at the Microscale, iChEM, School of Chemistry and Materials Science, and National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui 230026, China
| | - Can Yu
- Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.,University of Chinese Academy of Sciences, Beijing 100049, China
| | - Xuan Zhao
- Department of Physics, Beijing Normal University, Beijing 100875, China
| | - Hao Wang
- Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.,Chemistry and Chemical Engineering Guangdong Laboratory, Shantou, Guangdong 515031, China
| | - Ran Long
- Hefei National Laboratory for Physical Sciences at the Microscale, iChEM, School of Chemistry and Materials Science, and National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui 230026, China
| | - Guozhen Zhang
- Hefei National Laboratory for Physical Sciences at the Microscale, iChEM, School of Chemistry and Materials Science, and National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui 230026, China
| | - Chao Gao
- Hefei National Laboratory for Physical Sciences at the Microscale, iChEM, School of Chemistry and Materials Science, and National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui 230026, China
| | - Wenkai Zhang
- Department of Physics, Beijing Normal University, Beijing 100875, China
| | - Jun Jiang
- Hefei National Laboratory for Physical Sciences at the Microscale, iChEM, School of Chemistry and Materials Science, and National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui 230026, China
| | - Ye Tao
- Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
| | - Yujie Xiong
- Hefei National Laboratory for Physical Sciences at the Microscale, iChEM, School of Chemistry and Materials Science, and National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui 230026, China.,Dalian National Laboratory for Clean Energy, Dalian, Liaoning 116023, China
| |
Collapse
|
10
|
Burian M, Marmiroli B, Radeticchio A, Morello C, Naumenko D, Biasiol G, Amenitsch H. Picosecond pump-probe X-ray scattering at the Elettra SAXS beamline. JOURNAL OF SYNCHROTRON RADIATION 2020; 27:51-59. [PMID: 31868736 PMCID: PMC6927520 DOI: 10.1107/s1600577519015728] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Accepted: 11/20/2019] [Indexed: 06/10/2023]
Abstract
A new setup for picosecond pump-probe X-ray scattering at the Austrian SAXS beamline at Elettra-Sincrotrone Trieste is presented. A high-power/high-repetion-rate laser has been installed on-site, delivering UV/VIS/IR femtosecond-pulses in-sync with the storage ring. Data acquisition is achieved by gating a multi-panel detector, capable of discriminating the single X-ray pulse in the dark-gap of the Elettra hybrid filling mode. Specific aspects of laser- and detection-synchronization, on-line beam steering as well protocols for spatial and temporal overlap of laser and X-ray beam are also described. The capabilities of the setup are demonstrated by studying transient heat-transfer in an In/Al/GaAs superlattice structure and results are confirmed by theoretical calculations.
Collapse
Affiliation(s)
- Max Burian
- Institute of Inorganic Chemistry, Graz University of Technology, Stremayrgasse 9/V, 8010 Graz, Austria
| | - Benedetta Marmiroli
- Institute of Inorganic Chemistry, Graz University of Technology, Stremayrgasse 9/V, 8010 Graz, Austria
| | - Andrea Radeticchio
- Institute of Inorganic Chemistry, Graz University of Technology, Stremayrgasse 9/V, 8010 Graz, Austria
| | - Christian Morello
- Elettra-Sincrotrone Trieste SCpA, Strada Statale 14, km 163.5, Basovizza, TS 34149, Italy
| | - Denys Naumenko
- Institute of Inorganic Chemistry, Graz University of Technology, Stremayrgasse 9/V, 8010 Graz, Austria
| | - Giorgio Biasiol
- Laboratorio TASC, CNR-IOM at Area Science Park, Strada Statale 14, km 163.5, Basovizza, TS 34149, Italy
| | - Heinz Amenitsch
- Institute of Inorganic Chemistry, Graz University of Technology, Stremayrgasse 9/V, 8010 Graz, Austria
| |
Collapse
|
11
|
Yu C, Zhang Y, Lei G, Wang H, Wang YH, Zhang BB, Sun DR, Zhao JL, Zhou YF, Li QJ, Gao ZH, Zhan F, Tao Y. Upgrade of laser pump time-resolved X-ray probes in Beijing synchrotron. JOURNAL OF SYNCHROTRON RADIATION 2019; 26:2075-2080. [PMID: 31721753 DOI: 10.1107/s1600577519012724] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2019] [Accepted: 09/12/2019] [Indexed: 06/10/2023]
Abstract
The upgrade of the laser pump time-resolved X-ray probes, namely time-resolved X-ray absorption spectroscopy (TR-XAS) and X-ray diffraction (TR-XRD), implemented at the Beijing Synchrotron Radiation Facility, is described. The improvements include a superbunch fill, a high-efficiency fluorescence collection, an efficient spatial overlap protocol and a new data-acquisition scheme. After upgrade, the adequate TR-XAS signal is now obtained in a 0.3 mM solution, compared with a 6 mM solution in our previous report. Furthermore, to extend application in photophysics, the TR-XAS probe is applied on SrCoO2.5 thin film. And for the first time, TR-XAS is combined with TR-XRD to simultaneously detect the kinetic trace of structural changes in thin film.
Collapse
Affiliation(s)
- Can Yu
- Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing 100049, People's Republic of China
| | - Yan Zhang
- Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing 100049, People's Republic of China
| | - Ge Lei
- Accelerator Division, Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing 100049, People's Republic of China
| | - Hao Wang
- Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing 100049, People's Republic of China
| | - Yu Hang Wang
- Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing 100049, People's Republic of China
| | - Bing Bing Zhang
- Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing 100049, People's Republic of China
| | - Da Rui Sun
- Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing 100049, People's Republic of China
| | - Jia Li Zhao
- Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing 100049, People's Republic of China
| | - Yang Fan Zhou
- Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing 100049, People's Republic of China
| | - Qiu Ju Li
- Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing 100049, People's Republic of China
| | - Zhen Hua Gao
- Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing 100049, People's Republic of China
| | - Fei Zhan
- Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing 100049, People's Republic of China
| | - Ye Tao
- Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing 100049, People's Republic of China
| |
Collapse
|
12
|
Structural Kinetics of Cathode Events on Polymer Electrolyte Fuel Cell Catalysts Studied by Operando Time-Resolved XAFS. Catal Letters 2018. [DOI: 10.1007/s10562-018-2383-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
13
|
Fondell M, Eckert S, Jay RM, Weniger C, Quevedo W, Niskanen J, Kennedy B, Sorgenfrei F, Schick D, Giangrisostomi E, Ovsyannikov R, Adamczyk K, Huse N, Wernet P, Mitzner R, Föhlisch A. Time-resolved soft X-ray absorption spectroscopy in transmission mode on liquids at MHz repetition rates. STRUCTURAL DYNAMICS (MELVILLE, N.Y.) 2017; 4:054902. [PMID: 28852689 PMCID: PMC5555770 DOI: 10.1063/1.4993755] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2017] [Accepted: 08/07/2017] [Indexed: 05/06/2023]
Abstract
We present a setup combining a liquid flatjet sample delivery and a MHz laser system for time-resolved soft X-ray absorption measurements of liquid samples at the high brilliance undulator beamline UE52-SGM at Bessy II yielding unprecedented statistics in this spectral range. We demonstrate that the efficient detection of transient absorption changes in transmission mode enables the identification of photoexcited species in dilute samples. With iron(II)-trisbipyridine in aqueous solution as a benchmark system, we present absorption measurements at various edges in the soft X-ray regime. In combination with the wavelength tunability of the laser system, the set-up opens up opportunities to study the photochemistry of many systems at low concentrations, relevant to materials sciences, chemistry, and biology.
Collapse
Affiliation(s)
- Mattis Fondell
- Institute for Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin für Materialien und Energie, Albert-Einstein-Str. 15, 12489 Berlin, Germany
| | - Sebastian Eckert
- Institut für Physik und Astronomie, Universität Potsdam, Karl-Liebknecht-Strasse 24-25, 14476 Potsdam, Germany
| | - Raphael M Jay
- Institut für Physik und Astronomie, Universität Potsdam, Karl-Liebknecht-Strasse 24-25, 14476 Potsdam, Germany
| | - Christian Weniger
- Institute for Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin für Materialien und Energie, Albert-Einstein-Str. 15, 12489 Berlin, Germany
| | - Wilson Quevedo
- Institute for Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin für Materialien und Energie, Albert-Einstein-Str. 15, 12489 Berlin, Germany
| | - Johannes Niskanen
- Institute for Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin für Materialien und Energie, Albert-Einstein-Str. 15, 12489 Berlin, Germany
| | - Brian Kennedy
- Institute for Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin für Materialien und Energie, Albert-Einstein-Str. 15, 12489 Berlin, Germany
| | - Florian Sorgenfrei
- Institut für Physik und Astronomie, Universität Potsdam, Karl-Liebknecht-Strasse 24-25, 14476 Potsdam, Germany
| | - Daniel Schick
- Institute for Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin für Materialien und Energie, Albert-Einstein-Str. 15, 12489 Berlin, Germany
| | - Erika Giangrisostomi
- Institute for Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin für Materialien und Energie, Albert-Einstein-Str. 15, 12489 Berlin, Germany
| | - Ruslan Ovsyannikov
- Institute for Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin für Materialien und Energie, Albert-Einstein-Str. 15, 12489 Berlin, Germany
| | - Katrin Adamczyk
- Department of Physics, University of Hamburg and Center for Free-Electron Laser Science, Luruper Chaussee 149, 22761 Hamburg, Germany
| | - Nils Huse
- Department of Physics, University of Hamburg and Center for Free-Electron Laser Science, Luruper Chaussee 149, 22761 Hamburg, Germany
| | - Philippe Wernet
- Institute for Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin für Materialien und Energie, Albert-Einstein-Str. 15, 12489 Berlin, Germany
| | - Rolf Mitzner
- Institute for Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin für Materialien und Energie, Albert-Einstein-Str. 15, 12489 Berlin, Germany
| | | |
Collapse
|
14
|
Yang B, Yang QQ, Jiang X, Chen B, Tung CH, Wu LZ. Tracking the FeIV(O) intermediate and O–O bond formation of a nonheme iron catalyst for water oxidation. Chem Commun (Camb) 2017; 53:9063-9066. [DOI: 10.1039/c7cc04814a] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We describe here a new complex 1 by subtle modulation of the TPA ligand and succeed in capturing the high-valent FeIV(O) species, which is responsible for the O–O bond formation and oxygen evolution with higher efficiency.
Collapse
Affiliation(s)
- Bing Yang
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials
- Technical Institute of Physics and Chemistry & University of Chinese Academy of Sciences
- Chinese Academy of Sciences
- Beijing 100190
- P. R. China
| | - Qing-Qing Yang
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials
- Technical Institute of Physics and Chemistry & University of Chinese Academy of Sciences
- Chinese Academy of Sciences
- Beijing 100190
- P. R. China
| | - Xin Jiang
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials
- Technical Institute of Physics and Chemistry & University of Chinese Academy of Sciences
- Chinese Academy of Sciences
- Beijing 100190
- P. R. China
| | - Bin Chen
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials
- Technical Institute of Physics and Chemistry & University of Chinese Academy of Sciences
- Chinese Academy of Sciences
- Beijing 100190
- P. R. China
| | - Chen-Ho Tung
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials
- Technical Institute of Physics and Chemistry & University of Chinese Academy of Sciences
- Chinese Academy of Sciences
- Beijing 100190
- P. R. China
| | - Li-Zhu Wu
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials
- Technical Institute of Physics and Chemistry & University of Chinese Academy of Sciences
- Chinese Academy of Sciences
- Beijing 100190
- P. R. China
| |
Collapse
|