1
|
Schaeper JJ, Kampshoff CA, Wolf BJ, Roos L, Michanski S, Ruhwedel T, Eckermann M, Meyer A, Jeschke M, Wichmann C, Moser T, Salditt T. 3D virtual histology of rodent and primate cochleae with multi-scale phase-contrast X-ray tomography. Sci Rep 2025; 15:7933. [PMID: 40050327 PMCID: PMC11885485 DOI: 10.1038/s41598-025-89431-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2024] [Accepted: 02/05/2025] [Indexed: 03/09/2025] Open
Abstract
Multi-scale X-ray phase contrast tomography (XPCT) enables three-dimensional (3D), non-destructive imaging of intact small animal cochlea and apical cochlear turns. Here we report on post-mortem imaging of excised non-human primate and rodent cochleae at different [Formula: see text]-CT and nano-CT synchrotron instruments. We explore different sample embeddings, stainings and imaging regimes. Under optimized conditions of sample preparation, instrumentation, imaging protocol, and phase retrieval, high image quality and detail level can be achieved in 3D reconstructions. The showcased instrumentation and imaging protocols along with the reconstucted volumes can serve as benchmarks and reference for multi-scale microanatomy and 3D histology. The provided benchmarks and imaging protocols of this work cover a wide range of scales and are intended as augmented imaging tools for auditory research.
Collapse
Affiliation(s)
- Jannis J Schaeper
- Institute for X-Ray Physics, University of Göttingen, 37077, Göttingen, Germany
- Cluster of Excellence "Multiscale Bioimaging: From Molecular Machines to Networks of Excitable Cells", University of Göttingen, 37075, Göttingen, Germany
| | - Christoph A Kampshoff
- Department of Otolaryngology, University Medical Center Göttingen, 37075, Göttingen, Germany
- Institute for Auditory Neuroscience and Inner Ear Lab, University Medical Center Göttingen, 37075, Göttingen, Germany
| | - Bettina J Wolf
- Institute for Auditory Neuroscience and Inner Ear Lab, University Medical Center Göttingen, 37075, Göttingen, Germany
- Else-Kröner-Fresenius Center for Optogenetic Therapies, University Medical Center Göttingen, 37075, Göttingen, Germany
- Cluster of Excellence "Multiscale Bioimaging: From Molecular Machines to Networks of Excitable Cells", University of Göttingen, 37075, Göttingen, Germany
| | - Lennart Roos
- Department of Otolaryngology, University Medical Center Göttingen, 37075, Göttingen, Germany
- Institute for Auditory Neuroscience and Inner Ear Lab, University Medical Center Göttingen, 37075, Göttingen, Germany
- Else-Kröner-Fresenius Center for Optogenetic Therapies, University Medical Center Göttingen, 37075, Göttingen, Germany
- Cluster of Excellence "Multiscale Bioimaging: From Molecular Machines to Networks of Excitable Cells", University of Göttingen, 37075, Göttingen, Germany
| | - Susann Michanski
- Institute for Auditory Neuroscience and Inner Ear Lab, University Medical Center Göttingen, 37075, Göttingen, Germany
- Molecular Architecture of Synapses Group, Institute for Auditory Neuroscience and InnerEarLab, University Medical Center Göttingen, Göttingen, Germany
- University Medical Center Göttingen, Center for Biostructural Imaging of Neurodegeneration, Göttingen, Germany
| | - Torben Ruhwedel
- Max Planck Institute for Multidisciplinary Sciences, 37075, Göttingen, Germany
| | - Marina Eckermann
- Beamline ID16A, European Synchrotron Radiation Facility, 38000, Grenoble, France
| | - Alexander Meyer
- Department of Otolaryngology, University Medical Center Göttingen, 37075, Göttingen, Germany
| | - Marcus Jeschke
- Institute for Auditory Neuroscience and Inner Ear Lab, University Medical Center Göttingen, 37075, Göttingen, Germany
- Cognitive Hearing in Primates Group, German Primate Center, 37077, Göttingen, Germany
- Else-Kröner-Fresenius Center for Optogenetic Therapies, University Medical Center Göttingen, 37075, Göttingen, Germany
| | - Carolin Wichmann
- Institute for Auditory Neuroscience and Inner Ear Lab, University Medical Center Göttingen, 37075, Göttingen, Germany
- Molecular Architecture of Synapses Group, Institute for Auditory Neuroscience and InnerEarLab, University Medical Center Göttingen, Göttingen, Germany
- University Medical Center Göttingen, Center for Biostructural Imaging of Neurodegeneration, Göttingen, Germany
- Cluster of Excellence "Multiscale Bioimaging: From Molecular Machines to Networks of Excitable Cells", University of Göttingen, 37075, Göttingen, Germany
| | - Tobias Moser
- Department of Otolaryngology, University Medical Center Göttingen, 37075, Göttingen, Germany
- Institute for Auditory Neuroscience and Inner Ear Lab, University Medical Center Göttingen, 37075, Göttingen, Germany
- Auditory Neuroscience and Synaptic Nanophysiology Group, Max-Planck-Institute for Multidisciplinary Sciences, Göttingen, Germany
- Else-Kröner-Fresenius Center for Optogenetic Therapies, University Medical Center Göttingen, 37075, Göttingen, Germany
- Cluster of Excellence "Multiscale Bioimaging: From Molecular Machines to Networks of Excitable Cells", University of Göttingen, 37075, Göttingen, Germany
| | - Tim Salditt
- Institute for X-Ray Physics, University of Göttingen, 37077, Göttingen, Germany.
- Cluster of Excellence "Multiscale Bioimaging: From Molecular Machines to Networks of Excitable Cells", University of Göttingen, 37075, Göttingen, Germany.
| |
Collapse
|
2
|
Kjer HM, Andersson M, He Y, Pacureanu A, Daducci A, Pizzolato M, Salditt T, Robisch AL, Eckermann M, Töpperwien M, Bjorholm Dahl A, Elkjær ML, Illes Z, Ptito M, Andersen Dahl V, Dyrby TB. Bridging the 3D geometrical organisation of white matter pathways across anatomical length scales and species. eLife 2025; 13:RP94917. [PMID: 40019134 PMCID: PMC11870653 DOI: 10.7554/elife.94917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/01/2025] Open
Abstract
We used diffusion MRI and x-ray synchrotron imaging on monkey and mice brains to examine the organisation of fibre pathways in white matter across anatomical scales. We compared the structure in the corpus callosum and crossing fibre regions and investigated the differences in cuprizone-induced demyelination in mouse brains versus healthy controls. Our findings revealed common principles of fibre organisation that apply despite the varying patterns observed across species; small axonal fasciculi and major bundles formed laminar structures with varying angles, according to the characteristics of major pathways. Fasciculi exhibited non-straight paths around obstacles like blood vessels, comparable across the samples of varying fibre complexity and demyelination. Quantifications of fibre orientation distributions were consistent across anatomical length scales and modalities, whereas tissue anisotropy had a more complex relationship, both dependent on the field-of-view. Our study emphasises the need to balance field-of-view and voxel size when characterising white matter features across length scales.
Collapse
Affiliation(s)
- Hans Martin Kjer
- Danish Research Centre for Magnetic Resonance, Center for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and HvidovreHvidovreDenmark
- Department of Applied Mathematics and Computer Science, Technical University of DenmarkKongens LyngbyDenmark
| | - Mariam Andersson
- Danish Research Centre for Magnetic Resonance, Center for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and HvidovreHvidovreDenmark
- Department of Applied Mathematics and Computer Science, Technical University of DenmarkKongens LyngbyDenmark
| | - Yi He
- Danish Research Centre for Magnetic Resonance, Center for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and HvidovreHvidovreDenmark
- Guangdong Provincial Engineering Research Center of Molecular Imaging, The Fifth Affiliated Hospital, Sun Yat-sen UniversityZhuhaiChina
| | | | | | - Marco Pizzolato
- Department of Applied Mathematics and Computer Science, Technical University of DenmarkKongens LyngbyDenmark
| | - Tim Salditt
- Institut für Röntgenphysik, Universität Göttingen, Friedrich-Hund-PlatzGöttingenGermany
| | - Anna-Lena Robisch
- Institut für Röntgenphysik, Universität Göttingen, Friedrich-Hund-PlatzGöttingenGermany
| | - Marina Eckermann
- ESRF - The European SynchrotronGrenobleFrance
- Institut für Röntgenphysik, Universität Göttingen, Friedrich-Hund-PlatzGöttingenGermany
| | - Mareike Töpperwien
- Institut für Röntgenphysik, Universität Göttingen, Friedrich-Hund-PlatzGöttingenGermany
| | - Anders Bjorholm Dahl
- Department of Applied Mathematics and Computer Science, Technical University of DenmarkKongens LyngbyDenmark
| | - Maria Louise Elkjær
- Department of Neurology, Odense University HospitalOdenseDenmark
- Institute of Molecular Medicine, University of Southern DenmarkOdenseDenmark
| | - Zsolt Illes
- Department of Neurology, Odense University HospitalOdenseDenmark
- Institute of Molecular Medicine, University of Southern DenmarkOdenseDenmark
- BRIDGE—Brain Research—Inter-Disciplinary Guided Excellence, Department of Clinical Research, University of Southern DenmarkOdenseDenmark
- Rheumatology Research Unit, Odense University HospitalOdenseDenmark
| | - Maurice Ptito
- Department of Applied Mathematics and Computer Science, Technical University of DenmarkKongens LyngbyDenmark
- School of Optometry, University of MontrealMontrealCanada
| | - Vedrana Andersen Dahl
- Department of Applied Mathematics and Computer Science, Technical University of DenmarkKongens LyngbyDenmark
| | - Tim B Dyrby
- Danish Research Centre for Magnetic Resonance, Center for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and HvidovreHvidovreDenmark
- Department of Applied Mathematics and Computer Science, Technical University of DenmarkKongens LyngbyDenmark
| |
Collapse
|
3
|
Frohn J, Böddeker F, Reichardt M, Bruns H, Czajka T, Khan A, Broche L, Krisch M, Bravin A, Alves F, Zschüntzsch J, Salditt T. Three-dimensional structure of entire hydrated murine hearts at histological resolution. Sci Rep 2025; 15:2766. [PMID: 39843542 PMCID: PMC11754897 DOI: 10.1038/s41598-024-83853-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Accepted: 12/18/2024] [Indexed: 01/24/2025] Open
Abstract
Imaging the entire cardiomyocyte network in entire small animal hearts at single cell resolution is a formidable challenge. Optical microscopy provides sufficient contrast and resolution in 2d, however fails to deliver non-destructive 3d reconstructions with isotropic resolution. It requires several invasive preparation steps, which introduce structural artefacts, namely dehydration, physical slicing and staining, or for the case of light sheet microscopy also clearing of the tissue. Our goal is to provide 3d reconstructions of the cardiomyocyte network in entire hydrated murine hearts, and to develop a methodology for quantitative analysis of heart pathologies based on X-ray phase contrast computed tomography (XPCT). We have used XPCT at two beamlines of the extremely brilliant source (EBS) at the European Synchrotron Radiation Facility (ESRF) to scan wild-type murine hearts at high resolution, as well as a series of murine hearts of different pathological models, at reduced resolution and higher throughput. All hearts were obtained from the small animal facility of the university medical center in Göttingen. The hearts were fixed in formalin, stored and measured non-destructively in phosphate buffer solution. The high resolution dataset allows to discern individual cardiomyocytes in the tissue. All datasets have been analyzed using semi-automated image segmentation of the ventricles, rotation into a common coordinate system, classification into different anatomical compartments, and finally the structure tensor approach. A 3d streamline representation of the cardiomyocyte orientation vector field is provided. The different cardiovascular disease models are analysed based on metrics derived from the 3d structure tensor. An entire hydrated murine heart has been covered at an isotropic voxel size of 1.6 μ m (distributed over several volumes). A binned and fused dataset of this heart is available at 3.2 μ m, and has been analyzed by the structure tensor approach to yield the ventricular cardiomyocyte network or mesh, i.e. the aggregation of the cardiomyocyte chains in particular in the ventricular wall. Semi-automatic determination of structural metrics is already achieved and the corresponding tools and resulting data are made publically available. XPCT using extremely brilliant undulator radiation is close to achieve single cell reconstruction in an entire small animal organ.
Collapse
Affiliation(s)
- Jasper Frohn
- Institute for X-ray Physics, Georg-August University Göttingen, Friedrich-Hund-Platz 1, 37077, Göttingen, Germany
| | - Frederik Böddeker
- Institute for X-ray Physics, Georg-August University Göttingen, Friedrich-Hund-Platz 1, 37077, Göttingen, Germany
| | - Marius Reichardt
- Institute for X-ray Physics, Georg-August University Göttingen, Friedrich-Hund-Platz 1, 37077, Göttingen, Germany
| | - Hendrik Bruns
- Institute for X-ray Physics, Georg-August University Göttingen, Friedrich-Hund-Platz 1, 37077, Göttingen, Germany
| | - Titus Czajka
- Institute for X-ray Physics, Georg-August University Göttingen, Friedrich-Hund-Platz 1, 37077, Göttingen, Germany
| | - Amara Khan
- Georg-August University Göttingen, University Medical Center Göttingen, 37075, Göttingen, Germany
| | - Ludovic Broche
- Multiscale Bioimaging: From Molecular Machines to Networks of Excitable Cells (MBExC), Grenoble, France
| | - Michael Krisch
- Multiscale Bioimaging: From Molecular Machines to Networks of Excitable Cells (MBExC), Grenoble, France
| | - Alberto Bravin
- Multiscale Bioimaging: From Molecular Machines to Networks of Excitable Cells (MBExC), Grenoble, France
| | - Frauke Alves
- Georg-August University Göttingen, University Medical Center Göttingen, 37075, Göttingen, Germany
- European Synchrotron Radiation Facility, Grenoble, France
| | - Jana Zschüntzsch
- Georg-August University Göttingen, University Medical Center Göttingen, 37075, Göttingen, Germany
| | - Tim Salditt
- Institute for X-ray Physics, Georg-August University Göttingen, Friedrich-Hund-Platz 1, 37077, Göttingen, Germany.
- European Synchrotron Radiation Facility, Grenoble, France.
| |
Collapse
|
4
|
Gerhardt B, Alfken J, Reichmann J, Salditt T, Brecht M. Three-dimensional architecture and linearized mapping of vibrissa follicle afferents. Nat Commun 2025; 16:499. [PMID: 39779697 PMCID: PMC11711312 DOI: 10.1038/s41467-024-55468-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2024] [Accepted: 12/11/2024] [Indexed: 01/11/2025] Open
Abstract
Understanding vibrissal transduction has advanced by serial sectioning and identified afferent recordings, but afferent mapping onto the complex, encapsulated follicle remains unclear. Here, we reveal male rat C2 vibrissa follicle innervation through synchrotron X-ray phase contrast tomograms. Morphological analysis identified 5% superficial, ~32 % unmyelinated and 63% myelinated deep vibrissal nerve axons. Myelinated afferents consist of each one third Merkel and club-like, and one sixth Ruffini-like and lanceolate endings. Unsupervised clustering of afferent properties aligns with classic morphological categories and revealed previously unrecognized club-like afferent subtypes distinct in axon diameter and Ranvier internode distance. Myelination and axon diameters indicate a proximal-to-distal axon-velocity gradient along the follicle. Axons innervate preferentially dorso-caudally to the vibrissa, presumably to sample contacts from vibrissa protraction. Afferents organize in axon-arms innervating discrete angular territories. The radial axon-arm arrangement around the vibrissa maps into a linear representation of axon-arm bands in the nerve. Such follicle linearization presumably instructs downstream linear brainstem barrelettes. Synchrotron imaging provides a synopsis of afferents and mechanotransductory machinery.
Collapse
Affiliation(s)
- Ben Gerhardt
- Bernstein Center for Computational Neuroscience Berlin, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Jette Alfken
- Institut für Röntgenphysik, Universität Göttingen, Göttingen, Germany
| | - Jakob Reichmann
- Institut für Röntgenphysik, Universität Göttingen, Göttingen, Germany
| | - Tim Salditt
- Institut für Röntgenphysik, Universität Göttingen, Göttingen, Germany
| | - Michael Brecht
- Bernstein Center for Computational Neuroscience Berlin, Humboldt-Universität zu Berlin, Berlin, Germany.
- NeuroCure Cluster of Excellence, Humboldt-Universität zu Berlin, Berlin, Germany.
| |
Collapse
|
5
|
Peruzzi N, Eckermann M, Frohn J, Salditt T, Ohlsson B, Bech M. Volumetric changes of the enteric nervous system under physiological and pathological conditions measured using x-ray phase-contrast tomography. JGH Open 2024; 8:e70027. [PMID: 39295850 PMCID: PMC11408747 DOI: 10.1002/jgh3.70027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 07/30/2024] [Accepted: 09/01/2024] [Indexed: 09/21/2024]
Abstract
Background and Aim Full-thickness biopsies of the intestinal wall may be used to study and assess damage to the neurons of the enteric nervous system (ENS), that is, enteric neuropathy. The ENS is difficult to examine due to its localization deep in the intestinal wall and its organization with several connections in diverging directions. Histological sections used in clinical practice only visualize the sample in a two-dimensional way. X-ray phase-contrast micro-computed tomography (PC-μCT) has shown potential to assess the cross-sectional thickness and volume of the ENS in three dimensions (3D). The aim of this study was to explore the potential of PC-μCT to evaluate its use to determine the size of the ENS. Methods Full-thickness biopsies of ileum obtained during surgery from five controls and six patients clinically diagnosed with enteric neuropathy and dysmotility were included. Punch biopsies of 1 mm in diameter and 1 cm in length, from an area containing myenteric plexus, were extracted from paraffin blocks, and scanned with synchrotron-based PC-μCT without any staining. Results The microscopic volumetric structure of the neural tissue (consisting of both ganglia and fascicles) could be determined in all samples. The ratio of neural tissue volume/total tissue volume was higher in controls than in patients with enteric neuropathy (P = 0.013). The patient with the longest disease duration had the lowest ratio. Conclusion The assessment of neural tissue can be performed in an objective, standardized way, to ensure reproducibility and comparison under physiological and pathological conditions. Further evaluation is needed to examine the role of this method in the diagnosis of enteric neuropathy.
Collapse
Affiliation(s)
- Niccolò Peruzzi
- Medical Radiation Physics, Department of Clinical Sciences Lund Lund University Lund Sweden
| | - Marina Eckermann
- ESRF, The European Synchrotron Grenoble France
- Institute for X-Ray Physics, University of Göttingen Göttingen Germany
- Cluster of Excellence "Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells" (MBExC), University of Göttingen Göttingen Germany
| | - Jasper Frohn
- Institute for X-Ray Physics, University of Göttingen Göttingen Germany
- Cluster of Excellence "Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells" (MBExC), University of Göttingen Göttingen Germany
| | - Tim Salditt
- Institute for X-Ray Physics, University of Göttingen Göttingen Germany
- Cluster of Excellence "Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells" (MBExC), University of Göttingen Göttingen Germany
| | - Bodil Ohlsson
- Department of Clinical Sciences Malmö Lund University Lund Sweden
- Department of Internal Medicine Skåne University Hospital Malmö Sweden
| | - Martin Bech
- Medical Radiation Physics, Department of Clinical Sciences Lund Lund University Lund Sweden
- LINXS Institute of advanced Neutron and X-ray Science (LINXS) Lund Sweden
| |
Collapse
|
6
|
Burchert JP, Frohn J, Rölleke U, Bruns H, Yu B, Gleber SC, Stange R, Busse M, Osterhoff M, Salditt T, Köster S. X-ray phase-contrast tomography of cells manipulated with an optical stretcher. JOURNAL OF SYNCHROTRON RADIATION 2024; 31:923-935. [PMID: 38861370 PMCID: PMC11226146 DOI: 10.1107/s1600577524003618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Accepted: 04/21/2024] [Indexed: 06/13/2024]
Abstract
X-rays can penetrate deeply into biological cells and thus allow for examination of their internal structures with high spatial resolution. In this study, X-ray phase-contrast imaging and tomography is combined with an X-ray-compatible optical stretcher and microfluidic sample delivery. Using this setup, individual cells can be kept in suspension while they are examined with the X-ray beam at a synchrotron. From the recorded holograms, 2D phase shift images that are proportional to the projected local electron density of the investigated cell can be calculated. From the tomographic reconstruction of multiple such projections the 3D electron density can be obtained. The cells can thus be studied in a hydrated or even living state, thus avoiding artifacts from freezing, drying or embedding, and can in principle also be subjected to different sample environments or mechanical strains. This combination of techniques is applied to living as well as fixed and stained NIH3T3 mouse fibroblasts and the effect of the beam energy on the phase shifts is investigated. Furthermore, a 3D algebraic reconstruction scheme and a dedicated mathematical description is used to follow the motion of the trapped cells in the optical stretcher for multiple rotations.
Collapse
Affiliation(s)
- Jan-Philipp Burchert
- Institute for X-ray PhysicsUniversity of GöttingenFriedrich-Hund-Platz 137077GöttingenGermany
- Cluster of Excellence Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells (MBExC)University of GöttingenGermany
| | - Jasper Frohn
- Institute for X-ray PhysicsUniversity of GöttingenFriedrich-Hund-Platz 137077GöttingenGermany
| | - Ulrike Rölleke
- Institute for X-ray PhysicsUniversity of GöttingenFriedrich-Hund-Platz 137077GöttingenGermany
| | - Hendrik Bruns
- Institute for X-ray PhysicsUniversity of GöttingenFriedrich-Hund-Platz 137077GöttingenGermany
| | - Boram Yu
- Institute for X-ray PhysicsUniversity of GöttingenFriedrich-Hund-Platz 137077GöttingenGermany
| | - Sophie-Charlotte Gleber
- Institute for X-ray PhysicsUniversity of GöttingenFriedrich-Hund-Platz 137077GöttingenGermany
| | | | - Madleen Busse
- Biomedical Physics, School of ScienceTechnical University MunichBoltzmannstraße 1185748GarchingGermany
- Munich Institute of Biomedical EngineeringTechnical University MunichBoltzmannstraße 1185748GarchingGermany
| | - Markus Osterhoff
- Institute for X-ray PhysicsUniversity of GöttingenFriedrich-Hund-Platz 137077GöttingenGermany
| | - Tim Salditt
- Institute for X-ray PhysicsUniversity of GöttingenFriedrich-Hund-Platz 137077GöttingenGermany
- Cluster of Excellence Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells (MBExC)University of GöttingenGermany
| | - Sarah Köster
- Institute for X-ray PhysicsUniversity of GöttingenFriedrich-Hund-Platz 137077GöttingenGermany
- Cluster of Excellence Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells (MBExC)University of GöttingenGermany
| |
Collapse
|
7
|
Flenner S, Kubec A, David C, Greving I, Hagemann J. Dual-beam X-ray nano-holotomography. JOURNAL OF SYNCHROTRON RADIATION 2024; 31:916-922. [PMID: 38917016 PMCID: PMC11226161 DOI: 10.1107/s1600577524003801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Accepted: 04/25/2024] [Indexed: 06/27/2024]
Abstract
Nanotomography with hard X-rays is a widely used technique for high-resolution imaging, providing insights into the structure and composition of various materials. In recent years, tomographic approaches based on simultaneous illuminations of the same sample region from different angles by multiple beams have been developed at micrometre image resolution. Transferring these techniques to the nanoscale is challenging due to the loss in photon flux by focusing the X-ray beam. We present an approach for multi-beam nanotomography using a dual-beam Fresnel zone plate (dFZP) in a near-field holography setup. The dFZP generates two nano-focused beams that overlap in the sample plane, enabling the simultaneous acquisition of two projections from slightly different angles. This first proof-of-principle implementation of the dual-beam setup allows for the efficient removal of ring artifacts and noise using machine-learning approaches. The results open new possibilities for full-field multi-beam nanotomography and pave the way for future advancements in fast holotomography and artifact-reduction techniques.
Collapse
Affiliation(s)
- Silja Flenner
- Helmholtz-Zentrum Hereon, Max-Planck-Straße 1, 21502Geesthacht, Germany
| | - Adam Kubec
- Paul Scherrer InstitutForschungsstrasse 1115232Villigen PSISwitzerland
| | - Christian David
- Paul Scherrer InstitutForschungsstrasse 1115232Villigen PSISwitzerland
| | - Imke Greving
- Helmholtz-Zentrum Hereon, Max-Planck-Straße 1, 21502Geesthacht, Germany
| | - Johannes Hagemann
- Center for X-ray and Nano Science – CXNSDeutsches Elektronen-Synchrotron – DESYNotkestraße 8522607HamburgGermany
- Helmholtz Imaging PlatformDeutsches Elektronen-Synchrotron DESYNotkestraße 8522607HamburgGermany
| |
Collapse
|
8
|
Reichmann J, Sarrazin C, Schmale S, Blaurock C, Balkema-Buschmann A, Schmitzer B, Salditt T. 3D imaging of SARS-CoV-2 infected hamster lungs by X-ray phase contrast tomography enables drug testing. Sci Rep 2024; 14:12348. [PMID: 38811688 PMCID: PMC11137149 DOI: 10.1038/s41598-024-61746-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2024] [Accepted: 05/09/2024] [Indexed: 05/31/2024] Open
Abstract
X-ray Phase Contrast Tomography (XPCT) based on wavefield propagation has been established as a high resolution three-dimensional (3D) imaging modality, suitable to reconstruct the intricate structure of soft tissues, and the corresponding pathological alterations. However, for biomedical research, more is needed than 3D visualisation and rendering of the cytoarchitecture in a few selected cases. First, the throughput needs to be increased to cover a statistically relevant number of samples. Second, the cytoarchitecture has to be quantified in terms of morphometric parameters, independent of visual impression. Third, dimensionality reduction and classification are required for identification of effects and interpretation of results. To address these challenges, we here design and implement a novel integrated and high throughput XPCT imaging and analysis workflow for 3D histology, pathohistology and drug testing. Our approach uses semi-automated data acquisition, reconstruction and statistical quantification. We demonstrate its capability for the example of lung pathohistology in Covid-19. Using a small animal model, different Covid-19 drug candidates are administered after infection and tested in view of restoration of the physiological cytoarchitecture, specifically the alveolar morphology. To this end, we then use morphometric parameter determination followed by a dimensionality reduction and classification based on optimal transport. This approach allows efficient discrimination between physiological and pathological lung structure, thereby providing quantitative insights into the pathological progression and partial recovery due to drug treatment. Finally, we stress that the XPCT image chain implemented here only used synchrotron radiation for validation, while the data used for analysis was recorded with laboratory μ CT radiation, more easily accessible for pre-clinical research.
Collapse
Affiliation(s)
- Jakob Reichmann
- Georg-August-University of Göttingen, Institute for X-Ray Physics, Friedrich-Hund-Platz 1, 37077, Göttingen, Germany
| | - Clement Sarrazin
- Georg-August-University of Göttingen, Institute of Computer Science, Goldschmidtstraße 7, 37077, Göttingen, Germany
- Equipe RAPSODI, Centre INRIA de l'université de Lille, F-59000, Lille, France
| | - Sebastian Schmale
- Georg-August-University of Göttingen, Institute of Computer Science, Goldschmidtstraße 7, 37077, Göttingen, Germany
| | - Claudia Blaurock
- Friedrich-Loeffler-Institute, Südufer 10, 17493, Greifswald, Insel Riems, Germany
| | | | - Bernhard Schmitzer
- Georg-August-University of Göttingen, Institute of Computer Science, Goldschmidtstraße 7, 37077, Göttingen, Germany.
| | - Tim Salditt
- Georg-August-University of Göttingen, Institute for X-Ray Physics, Friedrich-Hund-Platz 1, 37077, Göttingen, Germany.
| |
Collapse
|
9
|
Shi K, Zhang X, Wang X, Xu J, Mu B, Yan J, Wang F, Ding Y, Wang Z. ICF-PR-Net: a deep phase retrieval neural network for X-ray phase contrast imaging of inertial confinement fusion capsules. OPTICS EXPRESS 2024; 32:14356-14376. [PMID: 38859383 DOI: 10.1364/oe.518249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Accepted: 03/25/2024] [Indexed: 06/12/2024]
Abstract
X-ray phase contrast imaging (XPCI) has demonstrated capability to characterize inertial confinement fusion (ICF) capsules, and phase retrieval can reconstruct phase information from intensity images. This study introduces ICF-PR-Net, a novel deep learning-based phase retrieval method for ICF-XPCI. We numerically constructed datasets based on ICF capsule shape features, and proposed an object-image loss function to add image formation physics to network training. ICF-PR-Net outperformed traditional methods as it exhibited satisfactory robustness against strong noise and nonuniform background and was well-suited for ICF-XPCI's constrained experimental conditions and single exposure limit. Numerical and experimental results showed that ICF-PR-Net accurately retrieved the phase and absorption while maintaining retrieval quality in different situations. Overall, the ICF-PR-Net enables the diagnosis of the inner interface and electron density of capsules to address ignition-preventing problems, such as hydrodynamic instability growth.
Collapse
|
10
|
Reichmann J, Ruhwedel T, Möbius W, Salditt T. Neodymium acetate as a contrast agent for X-ray phase-contrast tomography. J Med Imaging (Bellingham) 2023; 10:056001. [PMID: 37885921 PMCID: PMC10599332 DOI: 10.1117/1.jmi.10.5.056001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 08/08/2023] [Accepted: 10/02/2023] [Indexed: 10/28/2023] Open
Abstract
Purpose X-ray phase-contrast tomography (XPCT) is a non-destructive, three-dimensional imaging modality that provides higher contrast in soft tissue than absorption-based CT and allows one to cover the cytoarchitecture from the centi- and millimeter scale down to the nanoscale. To further increase contrast and resolution of XPCT, for example, in view of addressing connectivity issues in the central nervous system (CNS), metal staining is indispensable. However, currently used protocols, for example, based on osmium and/or uranium are less suited for XPCT, due to an excessive β / δ -ratio. In this work, we explore the suitability of different staining agents for XPCT. Particularly, neodymium(III)-acetate (NdAc), which has recently been proposed as a non-toxic, non-radioactive easy to use alternative contrast agent for uranyl acetate (UAc) in electron microscopy, is investigated. Due to its vertical proximity to UAc in the periodic table, similar chemical but better suited optical properties for phase contrast can be expected. Approach Differently stained whole eye samples of wild type mouse and tissues of the CNS are embedded into EPON epoxy resin and scanned using synchrotron as well as with laboratory radiation. Phase retrieval is performed on the projection images, followed by tomographic reconstruction, which enables a quantitative analysis based on the reconstructed electron densities. Segmentation techniques and rendering software is used to visualize structures of interest in the sample. Results We show that staining neuronal samples with NdAc enhances contrast, in particular for laboratory scans, allowing high-resolution imaging of biological soft tissue in-house. For the example of murine retina, specifically rods and cones as well as the sclera and the Ganglion cell layer seem to be targeted by the stain. A comparison of electron density by the evaluation of histograms allowed to determine quantitative measures to describe the difference between the examined stains. Conclusion The results suggest NdAc to be an effective stain for XPCT, with a preferential binding to anionic groups, such as phosphate and carboxyl groups at cell surfaces, targeting certain layers of the retina with a stronger selectivity compared to other staining agents. Due to the advantageous X-ray optical properties, the stain seems particularly well-suited for phase contrast, with a comparably small number density and an overall superior image quality at laboratory sources.
Collapse
Affiliation(s)
| | - Torben Ruhwedel
- Max Planck Institute for Multidisciplinary Sciences, Göttingen, Germany
| | - Wiebke Möbius
- Max Planck Institute for Multidisciplinary Sciences, Göttingen, Germany
| | - Tim Salditt
- Georg-August-University of Göttingen, Göttingen, Germany
| |
Collapse
|
11
|
Schaeper JJ, Liberman MC, Salditt T. Imaging of excised cochleae by micro-CT: staining, liquid embedding, and image modalities. J Med Imaging (Bellingham) 2023; 10:053501. [PMID: 37753271 PMCID: PMC10519431 DOI: 10.1117/1.jmi.10.5.053501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 08/29/2023] [Accepted: 08/31/2023] [Indexed: 09/28/2023] Open
Abstract
Purpose Assessing the complex three-dimensional (3D) structure of the cochlea is crucial to understanding the fundamental aspects of signal transduction in the inner ear and is a prerequisite for the development of novel cochlear implants. X-ray phase-contrast computed tomography offers destruction-free 3D imaging with little sample preparation, thus preserving the delicate structure of the cochlea. The use of heavy metal stains enables higher contrast and resolution and facilitates segmentation of the cochlea. Approach For μ-CT of small animal and human cochlea, we explore the heavy metal osmium tetroxide (OTO) as a radiocontrast agent and delineate laboratory μ - CT from synchrotron CT. We investigate how phase retrieval can be used to improve the image quality of the reconstructions, both for stained and unstained specimens. Results Image contrast for soft tissue in an aqueous solution is insufficient under the in-house conditions, whereas the OTO stain increases contrast for lipid-rich tissue components, such as the myelin sheaths in nervous tissue, enabling contrast-based rendering of the different components of the auditory nervous system. The overall morphology of the cochlea with the three scalae and membranes is very well represented. Further, the image quality of the reconstructions improves significantly when a phase retrieval scheme is used, which is also suitable for non-ideal laboratory μ - CT settings. With highly brilliant synchrotron radiation (SR), we achieve high contrast for unstained whole cochleae at the cellular level. Conclusions The OTO stain is suitable for 3D imaging of small animal and human cochlea with laboratory μ - CT , and relevant pathologies, such as a loss of sensory cells and neurons, can be visualized. With SR and optimized phase retrieval, the cellular level can be reached even for unstained samples in aqueous solution, as demonstrated by the high visibility of single hair cells and spiral ganglion neurons.
Collapse
Affiliation(s)
- Jannis Justus Schaeper
- University of Göttingen, Institute for X-ray Physics, Göttingen, Germany
- University of Göttingen, Cluster of Excellence “Multiscale Bioimaging: Molecular Machines to Networks of Excitable Cells,” Göttingen, Germany
| | - Michael Charles Liberman
- Massachusetts Eye and Ear Infirmary, Eaton-Peabody Laboratories, Boston, Massachusetts, United States
- Harvard Medical School, Department of Otolaryngology, Head and Neck Surgery, Boston, Massachusetts, United States
| | - Tim Salditt
- University of Göttingen, Institute for X-ray Physics, Göttingen, Germany
- University of Göttingen, Cluster of Excellence “Multiscale Bioimaging: Molecular Machines to Networks of Excitable Cells,” Göttingen, Germany
| |
Collapse
|
12
|
Lang JT, Kulkarni D, Foster CW, Huang Y, Sepe MA, Shimpalee S, Parkinson DY, Zenyuk IV. X-ray Tomography Applied to Electrochemical Devices and Electrocatalysis. Chem Rev 2023; 123:9880-9914. [PMID: 37579025 PMCID: PMC10450694 DOI: 10.1021/acs.chemrev.2c00873] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Indexed: 08/16/2023]
Abstract
X-ray computed tomography (CT) is a nondestructive three-dimensional (3D) imaging technique used for studying morphological properties of porous and nonporous materials. In the field of electrocatalysis, X-ray CT is mainly used to quantify the morphology of electrodes and extract information such as porosity, tortuosity, pore-size distribution, and other relevant properties. For electrochemical systems such as fuel cells, electrolyzers, and redox flow batteries, X-ray CT gives the ability to study evolution of critical features of interest in ex situ, in situ, and operando environments. These include catalyst degradation, interface evolution under real conditions, formation of new phases (water and oxygen), and dynamics of transport processes. These studies enable more efficient device and electrode designs that will ultimately contribute to widespread decarbonization efforts.
Collapse
Affiliation(s)
- Jack T. Lang
- Department
of Chemical and Biomolecular Engineering, University of California, Irvine, California 92617, United States
- National
Fuel Cell Research Center, University of
California, Irvine, California 92617, United States
| | - Devashish Kulkarni
- National
Fuel Cell Research Center, University of
California, Irvine, California 92617, United States
- Department
of Materials Science and Engineering, University
of California, Irvine, California 92617, United States
| | - Collin W. Foster
- Department
of Aerospace Engineering, University of
Illinois at Urbana−Champaign, Urbana, Illinois 61820, United States
| | - Ying Huang
- National
Fuel Cell Research Center, University of
California, Irvine, California 92617, United States
- Department
of Materials Science and Engineering, University
of California, Irvine, California 92617, United States
| | - Mitchell A. Sepe
- Hydrogen
and Fuel Cell Center, Department of Chemical Engineering, University of South Carolina, Columbia, South Carolina 29208, United States
| | - Sirivatch Shimpalee
- Hydrogen
and Fuel Cell Center, Department of Chemical Engineering, University of South Carolina, Columbia, South Carolina 29208, United States
| | - Dilworth Y. Parkinson
- Advanced
Light Source, Lawrence Berkeley National
Laboratory, Berkeley, California 94720, United States
| | - Iryna V. Zenyuk
- Department
of Chemical and Biomolecular Engineering, University of California, Irvine, California 92617, United States
- National
Fuel Cell Research Center, University of
California, Irvine, California 92617, United States
- Department
of Materials Science and Engineering, University
of California, Irvine, California 92617, United States
| |
Collapse
|
13
|
Zharov Y, Ametova E, Spiecker R, Baumbach T, Burca G, Heuveline V. Shot noise reduction in radiographic and tomographic multi-channel imaging with self-supervised deep learning. OPTICS EXPRESS 2023; 31:26226-26244. [PMID: 37710488 DOI: 10.1364/oe.492221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Accepted: 06/13/2023] [Indexed: 09/16/2023]
Abstract
Shot noise is a critical issue in radiographic and tomographic imaging, especially when additional constraints lead to a significant reduction of the signal-to-noise ratio. This paper presents a method for improving the quality of noisy multi-channel imaging datasets, such as data from time or energy-resolved imaging, by exploiting structural similarities between channels. To achieve that, we broaden the application domain of the Noise2Noise self-supervised denoising approach. The method draws pairs of samples from a data distribution with identical signals but uncorrelated noise. It is applicable to multi-channel datasets if adjacent channels provide images with similar enough information but independent noise. We demonstrate the applicability and performance of the method via three case studies, namely spectroscopic X-ray tomography, energy-dispersive neutron tomography, and in vivo X-ray cine-radiography.
Collapse
|
14
|
Pinkert-Leetsch D, Frohn J, Ströbel P, Alves F, Salditt T, Missbach-Guentner J. Three-dimensional analysis of human pancreatic cancer specimens by phase-contrast based X-ray tomography - the next dimension of diagnosis. Cancer Imaging 2023; 23:43. [PMID: 37131262 PMCID: PMC10152799 DOI: 10.1186/s40644-023-00559-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Accepted: 04/19/2023] [Indexed: 05/04/2023] Open
Abstract
BACKGROUND The worldwide increase of pancreatic ductal adenocarcinoma (PDAC), which still has one of the lowest survival rates, requires novel imaging tools to improve early detection and to refine diagnosis. Therefore, the aim of this study was to assess the feasibility of propagation-based phase-contrast X-ray computed tomography of already paraffin-embedded and unlabeled human pancreatic tumor tissue to achieve a detailed three-dimensional (3D) view of the tumor sample in its entirety. METHODS Punch biopsies of areas of particular interest were taken from paraffin blocks after initial histological analysis of hematoxylin and eosin stained tumor sections. To cover the entire 3.5 mm diameter of the punch biopsy, nine individual tomograms with overlapping regions were acquired in a synchrotron parallel beam configuration and stitched together after data reconstruction. Due to the intrinsic contrast based on electron density differences of tissue components and a voxel size of 1.3 μm achieved PDAC and its precursors were clearly identified. RESULTS Characteristic tissue structures for PDAC and its precursors, such as dilated pancreatic ducts, altered ductal epithelium, diffuse immune cell infiltrations, increased occurrence of tumor stroma and perineural invasion were clearly identified. Certain structures of interest were visualized in three dimensions throughout the tissue punch. Pancreatic duct ectasia of different caliber and atypical shape as well as perineural infiltration could be contiguously traced by viewing serial tomographic slices and by applying semi-automatic segmentation. Histological validation of corresponding sections confirmed the former identified PDAC features. CONCLUSION In conclusion, virtual 3D histology via phase-contrast X-ray tomography visualizes diagnostically relevant tissue structures of PDAC in their entirety, preserving tissue integrity in label-free, paraffin embedded tissue biopsies. In the future, this will not only enable a more comprehensive diagnosis but also a possible identification of new 3D imaging tumor markers.
Collapse
Affiliation(s)
- Diana Pinkert-Leetsch
- Department of Diagnostic and Interventional Radiology, University Medical Center, Goettingen, Germany.
| | - Jasper Frohn
- Institute for X-ray Physics, Georg-August-University, Goettingen, Germany
| | - Philipp Ströbel
- Department of Pathology, University Medical Center, Goettingen, Germany
| | - Frauke Alves
- Department of Diagnostic and Interventional Radiology, University Medical Center, Goettingen, Germany
- Cluster of Excellence "Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells" (MBExC), University of Goettingen, Goettingen, Germany
- Department of Hematology and Medical Oncology, University Medical Center, Goettingen, Germany
- Translational Molecular Imaging, Max-Planck-Institute for Multidisciplinary Sciences, Goettingen, Germany
| | - Tim Salditt
- Institute for X-ray Physics, Georg-August-University, Goettingen, Germany
- Cluster of Excellence "Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells" (MBExC), University of Goettingen, Goettingen, Germany
| | | |
Collapse
|
15
|
Frost J, Schmitzer B, Töpperwien M, Eckermann M, Franz J, Stadelmann C, Salditt T. 3d virtual histology reveals pathological alterations of cerebellar granule cells in multiple sclerosis. Neuroscience 2023; 520:18-38. [PMID: 37061161 DOI: 10.1016/j.neuroscience.2023.04.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 03/10/2023] [Accepted: 04/03/2023] [Indexed: 04/17/2023]
Abstract
We investigate structural properties of neurons in the granular layer of human cerebellum with respect to their involvement in multiple sclerosis (MS). To this end we analyze data recorded by X-ray phase contrast tomography from tissue samples collected post mortem from a MS and a healthy control group. Using automated segmentation and histogram analysis based on optimal transport theory (OT) we find that the distributions representing nuclear structure in the granular layer move to a more compact nuclear state, i.e. smaller, denser and more heterogeneous nuclei in MS. We have previously made a similar observation for neurons of the dentate gyrus in Alzheimer's disease, suggesting that more compact structure of neuronal nuclei which we attributed to increased levels of heterochromatin, may possibly represent a more general phenomenon of cellular senescence associated with neurodegeneration.
Collapse
Affiliation(s)
- Jakob Frost
- Institute of X-ray Physics, Georg-August Universität Göttingen, Germany
| | - Bernhard Schmitzer
- Institute of Computer Science, Georg-August Universität Göttingen, Germany
| | - Mareike Töpperwien
- Institute of X-ray Physics, Georg-August Universität Göttingen, Germany; Present address: ESRF, Grenoble, France; Present adress: YXLON GmbH, Hamburg, Germany
| | - Marina Eckermann
- Institute of X-ray Physics, Georg-August Universität Göttingen, Germany; Present address: ESRF, Grenoble, France
| | - Jonas Franz
- Institute of Neuropathology, Universical Medical Center Göttingen, Germany
| | - Christine Stadelmann
- Institute of Neuropathology, Universical Medical Center Göttingen, Germany; Cluster of Excellence 'Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells' (MBExC), Georg-August Universität Göttingen, Germany
| | - Tim Salditt
- Institute of X-ray Physics, Georg-August Universität Göttingen, Germany; Cluster of Excellence 'Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells' (MBExC), Georg-August Universität Göttingen, Germany
| |
Collapse
|
16
|
Flenner S, Hagemann J, Wittwer F, Longo E, Kubec A, Rothkirch A, David C, Müller M, Greving I. Hard X-ray full-field nanoimaging using a direct photon-counting detector. JOURNAL OF SYNCHROTRON RADIATION 2023; 30:390-399. [PMID: 36891852 PMCID: PMC10000802 DOI: 10.1107/s1600577522012103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Accepted: 12/22/2022] [Indexed: 06/18/2023]
Abstract
Full-field X-ray nanoimaging is a widely used tool in a broad range of scientific areas. In particular, for low-absorbing biological or medical samples, phase contrast methods have to be considered. Three well established phase contrast methods at the nanoscale are transmission X-ray microscopy with Zernike phase contrast, near-field holography and near-field ptychography. The high spatial resolution, however, often comes with the drawback of a lower signal-to-noise ratio and significantly longer scan times, compared with microimaging. In order to tackle these challenges a single-photon-counting detector has been implemented at the nanoimaging endstation of the beamline P05 at PETRA III (DESY, Hamburg) operated by Helmholtz-Zentrum Hereon. Thanks to the long sample-to-detector distance available, spatial resolutions of below 100 nm were reached in all three presented nanoimaging techniques. This work shows that a single-photon-counting detector in combination with a long sample-to-detector distance allows one to increase the time resolution for in situ nanoimaging, while keeping a high signal-to-noise level.
Collapse
Affiliation(s)
- Silja Flenner
- Helmholtz-Zentrum Hereon, Max-Planck-Strasse 1, 21502 Geesthacht, Germany
| | - Johannes Hagemann
- Center for X-ray and Nano Science – CXNS, Deutsches Elektronen-Synchrotron – DESY, Notkestraße 85, 22607 Hamburg, Germany
| | - Felix Wittwer
- Center for X-ray and Nano Science – CXNS, Deutsches Elektronen-Synchrotron – DESY, Notkestraße 85, 22607 Hamburg, Germany
| | - Elena Longo
- Helmholtz-Zentrum Hereon, Max-Planck-Strasse 1, 21502 Geesthacht, Germany
| | - Adam Kubec
- Paul Scherrer Institut, Forschungsstrasse 111, 5232 Villigen, Switzerland
| | - André Rothkirch
- Center for X-ray and Nano Science – CXNS, Deutsches Elektronen-Synchrotron – DESY, Notkestraße 85, 22607 Hamburg, Germany
| | - Christian David
- Paul Scherrer Institut, Forschungsstrasse 111, 5232 Villigen, Switzerland
| | - Martin Müller
- Helmholtz-Zentrum Hereon, Max-Planck-Strasse 1, 21502 Geesthacht, Germany
| | - Imke Greving
- Helmholtz-Zentrum Hereon, Max-Planck-Strasse 1, 21502 Geesthacht, Germany
| |
Collapse
|
17
|
Wittmeier A, Bernhardt M, Robisch AL, Cassini C, Osterhoff M, Salditt T, Köster S. Combined optical fluorescence microscopy and X-ray tomography reveals substructures in cell nuclei in 3D. BIOMEDICAL OPTICS EXPRESS 2022; 13:4954-4969. [PMID: 36187264 PMCID: PMC9484410 DOI: 10.1364/boe.462493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Revised: 07/08/2022] [Accepted: 07/27/2022] [Indexed: 06/16/2023]
Abstract
The function of a biological cell is fundamentally defined by the structural architecture of packaged DNA in the nucleus. Elucidating information about the packaged DNA is facilitated by high-resolution imaging. Here, we combine and correlate hard X-ray propagation-based phase contrast tomography and visible light confocal microscopy in three dimensions to probe DNA in whole cell nuclei of NIH-3T3 fibroblasts. In this way, unlabeled and fluorescently labeled substructures within the cell are visualized in a complementary manner. Our approach enables the quantification of the electron density, volume and optical fluorescence intensity of nuclear material. By joining all of this information, we are able to spatially localize and physically characterize both active and inactive heterochromatin, euchromatin, pericentric heterochromatin foci and nucleoli.
Collapse
Affiliation(s)
- Andrew Wittmeier
- Institute for X-Ray Physics, University of Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| | - Marten Bernhardt
- Institute for X-Ray Physics, University of Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| | - Anna-Lena Robisch
- Institute for X-Ray Physics, University of Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| | - Chiara Cassini
- Institute for X-Ray Physics, University of Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
- Cluster of Excellence “Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells” (MBExC), University of Göttingen, Germany
| | - Markus Osterhoff
- Institute for X-Ray Physics, University of Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| | - Tim Salditt
- Institute for X-Ray Physics, University of Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
- Cluster of Excellence “Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells” (MBExC), University of Göttingen, Germany
| | - Sarah Köster
- Institute for X-Ray Physics, University of Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
- Cluster of Excellence “Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells” (MBExC), University of Göttingen, Germany
| |
Collapse
|
18
|
Huhn S, Lohse LM, Lucht J, Salditt T. Fast algorithms for nonlinear and constrained phase retrieval in near-field X-ray holography based on Tikhonov regularization. OPTICS EXPRESS 2022; 30:32871-32886. [PMID: 36242340 DOI: 10.1364/oe.462368] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Accepted: 08/02/2022] [Indexed: 06/16/2023]
Abstract
Based on phase retrieval, lensless coherent imaging and in particular holography offers quantitative phase and amplitude images. This is of particular importance for spectral ranges where suitable lenses are challenging, such as for hard x-rays. Here, we propose a phase retrieval approach for inline x-ray holography based on Tikhonov regularization applied to the full nonlinear forward model of image formation. The approach can be seen as a nonlinear generalization of the well-established contrast transfer function (CTF) reconstruction method. While similar methods have been proposed before, the current work achieves nonlinear, constrained phase retrieval at competitive computation times. We thus enable high-throughput imaging of optically strong objects beyond the scope of CTF. Using different examples of inline holograms obtained from illumination by a x-ray waveguide-source, we demonstrate superior image quality even for samples which do not obey the assumption of a weakly varying phase. Since the presented approach does not rely on linearization, we expect it to be well suited also for other probes such as visible light or electrons, which often exhibit strong phase interaction.
Collapse
|
19
|
Pil-Ali A, Adnani S, Scott CC, Karim KS. Direct Conversion X-ray Detector with Micron-Scale Pixel Pitch for Edge-Illumination and Propagation-Based X-ray Phase-Contrast Imaging. SENSORS (BASEL, SWITZERLAND) 2022; 22:5890. [PMID: 35957449 PMCID: PMC9371434 DOI: 10.3390/s22155890] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 08/04/2022] [Accepted: 08/05/2022] [Indexed: 06/15/2023]
Abstract
In this work, we investigate the potential of employing a direct conversion integration mode X-ray detector with micron-scale pixels in two different X-ray phase-contrast imaging (XPCi) configurations, propagation-based (PB) and edge illumination (EI). Both PB-XPCi and EI-XPCi implementations are evaluated through a wave optics model-numerically simulated in MATLAB-and are compared based on their contrast, edge-enhancement, visibility, and dose efficiency characteristics. The EI-XPCi configuration, in general, demonstrates higher performance compared to PB-XPCi, considering a setup with the same X-ray source and detector. However, absorption masks quality (thickness of X-ray absorption material) and environmental vibration effect are two potential challenges for EI-XPCi employing a detector with micron-scale pixels. Simulation results confirm that the behavior of an EI-XPCi system employing a high-resolution detector is susceptible to its absorption masks thickness and misalignment. This work demonstrates the potential and feasibility of employing a high-resolution direct conversion detector for phase-contrast imaging applications where higher dose efficiency, higher contrast images, and a more compact imaging system are of interest.
Collapse
Affiliation(s)
- Abdollah Pil-Ali
- Department of Electrical and Computer Engineering, University of Waterloo, 200 University Ave W, Waterloo, ON N2L 3G1, Canada
- Centre for Bioengineering and Biotechnology, University of Waterloo, 200 University Ave W, Waterloo, ON N2L 3G1, Canada
| | - Sahar Adnani
- Department of Electrical and Computer Engineering, University of Waterloo, 200 University Ave W, Waterloo, ON N2L 3G1, Canada
- Centre for Bioengineering and Biotechnology, University of Waterloo, 200 University Ave W, Waterloo, ON N2L 3G1, Canada
| | | | - Karim S. Karim
- Department of Electrical and Computer Engineering, University of Waterloo, 200 University Ave W, Waterloo, ON N2L 3G1, Canada
- Centre for Bioengineering and Biotechnology, University of Waterloo, 200 University Ave W, Waterloo, ON N2L 3G1, Canada
- KA Imaging, 560 Parkside Dr #3, Waterloo, ON N2L 5Z4, Canada
| |
Collapse
|
20
|
Veress B, Peruzzi N, Eckermann M, Frohn J, Salditt T, Bech M, Ohlsson B. Structure of the myenteric plexus in normal and diseased human ileum analyzed by X-ray virtual histology slices. World J Gastroenterol 2022; 28:3994-4006. [PMID: 36157532 PMCID: PMC9367237 DOI: 10.3748/wjg.v28.i29.3994] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 05/18/2022] [Accepted: 07/11/2022] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND The enteric nervous system (ENS) is situated along the entire gastrointestinal tract and is divided into myenteric and submucosal plexuses in the small and large intestines. The ENS consists of neurons, glial cells, and nerves assembled into ganglia, surrounded by telocytes, interstitial cells of Cajal, and connective tissue. Owing to the complex spatial organization of several interconnections with nerve fascicles, the ENS is difficult to examine in conventional histological sections of 3-5 μm.
AIM To examine human ileum full-thickness biopsies using X-ray phase-contrast nanotomography without prior staining to visualize the ENS.
METHODS Six patients were diagnosed with gastrointestinal dysmotility and neuropathy based on routine clinical and histopathological examinations. As controls, full-thickness biopsies were collected from healthy resection ileal regions after hemicolectomy for right colon malignancy. From the paraffin blocks, 4-µm thick sections were prepared and stained with hematoxylin and eosin for localization of the myenteric ganglia under a light microscope. A 1-mm punch biopsy (up to 1 cm in length) centered on the myenteric plexus was taken and placed into a Kapton® tube for mounting in the subsequent investigation. X-ray phase-contrast tomography was performed using two custom-designed laboratory setups with micrometer resolution for overview scanning. Subsequently, selected regions of interest were scanned at a synchrotron-based end-station, and high-resolution slices were reported. In total, more than 6000 virtual slices were analyzed from nine samples.
RESULTS In the overview scans, the general architecture and quality of the samples were studied, and the myenteric plexus was localized. High-resolution scans revealed details, including the ganglia, interganglional nerve fascicles, and surrounding tissue. The ganglia were irregular in shape and contained neurons and glial cells. Spindle-shaped cells with very thin cellular projections could be observed on the surface of the ganglia, which appeared to build a network. In the patients, there were no alterations in the general architecture of the myenteric ganglia. Nevertheless, several pathological changes were observed, including vacuolar degeneration, autophagic activity, the appearance of sequestosomes, chromatolysis, and apoptosis. Furthermore, possible expulsion of pyknotic neurons and defects in the covering cellular network could be observed in serial slices. These changes partly corresponded to previous light microscopy findings.
CONCLUSION The analysis of serial virtual slices could provide new information that cannot be obtained by classical light microscopy. The advantages, disadvantages, and future possibilities of this method are also discussed.
Collapse
Affiliation(s)
- Bela Veress
- Department of Pathology, Skåne Universiity Hospital, Malmö 205 02, Sweden
| | - Niccolò Peruzzi
- Medical Radiation Physics, Department of Clinical Sciences, Lund University, Lund 221 00, Sweden
| | - Marina Eckermann
- Institute for X-Ray Physics, University of Göttingen, Göttingen 37077, Germany
- Cluster of Excellence “Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells” (MBExC), University of Göttingen, Göttingen 37077, Germany
- ESRF, The European Synchrotron, Grenoble 38043, France
| | - Jasper Frohn
- Institute for X-Ray Physics, University of Göttingen, Göttingen 37077, Germany
| | - Tim Salditt
- Institute for X-Ray Physics, University of Göttingen, Göttingen 37077, Germany
- Cluster of Excellence “Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells” (MBExC), University of Göttingen, Göttingen 37077, Germany
| | - Martin Bech
- Medical Radiation Physics, Department of Clinical Sciences, Lund University, Lund 221 00, Sweden
| | - Bodil Ohlsson
- Department of Internal Medicine, Skåne University Hospital, Lund University, Malmö S-205 02, Sweden
| |
Collapse
|
21
|
Bosch C, Ackels T, Pacureanu A, Zhang Y, Peddie CJ, Berning M, Rzepka N, Zdora MC, Whiteley I, Storm M, Bonnin A, Rau C, Margrie T, Collinson L, Schaefer AT. Functional and multiscale 3D structural investigation of brain tissue through correlative in vivo physiology, synchrotron microtomography and volume electron microscopy. Nat Commun 2022; 13:2923. [PMID: 35614048 PMCID: PMC9132960 DOI: 10.1038/s41467-022-30199-6] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Accepted: 04/19/2022] [Indexed: 12/16/2022] Open
Abstract
Understanding the function of biological tissues requires a coordinated study of physiology and structure, exploring volumes that contain complete functional units at a detail that resolves the relevant features. Here, we introduce an approach to address this challenge: Mouse brain tissue sections containing a region where function was recorded using in vivo 2-photon calcium imaging were stained, dehydrated, resin-embedded and imaged with synchrotron X-ray computed tomography with propagation-based phase contrast (SXRT). SXRT provided context at subcellular detail, and could be followed by targeted acquisition of multiple volumes using serial block-face electron microscopy (SBEM). In the olfactory bulb, combining SXRT and SBEM enabled disambiguation of in vivo-assigned regions of interest. In the hippocampus, we found that superficial pyramidal neurons in CA1a displayed a larger density of spine apparati than deeper ones. Altogether, this approach can enable a functional and structural investigation of subcellular features in the context of cells and tissues.
Collapse
Affiliation(s)
- Carles Bosch
- Sensory Circuits and Neurotechnology Lab., The Francis Crick Institute, London, UK.
| | - Tobias Ackels
- Sensory Circuits and Neurotechnology Lab., The Francis Crick Institute, London, UK
- Department of Neuroscience, Physiology and Pharmacology, University College, London, UK
| | - Alexandra Pacureanu
- Sensory Circuits and Neurotechnology Lab., The Francis Crick Institute, London, UK
- Department of Neuroscience, Physiology and Pharmacology, University College, London, UK
- ESRF, The European Synchrotron, Grenoble, France
| | - Yuxin Zhang
- Sensory Circuits and Neurotechnology Lab., The Francis Crick Institute, London, UK
- Department of Neuroscience, Physiology and Pharmacology, University College, London, UK
| | | | - Manuel Berning
- Department of Connectomics, Max Planck Institute for Brain Research, Frankfurt am Main, Germany
- Scalable minds GmbH, Potsdam, Germany
| | | | - Marie-Christine Zdora
- Department of Physics and Astronomy, University College London, London, UK
- Diamond Light Source, Harwell Science and Innovation Campus, Didcot, UK
- School of Physics and Astronomy, University of Southampton, Highfield Campus, Southampton, UK
| | - Isabell Whiteley
- Sensory Circuits and Neurotechnology Lab., The Francis Crick Institute, London, UK
- Department of Neuroscience, Physiology and Pharmacology, University College, London, UK
| | - Malte Storm
- Diamond Light Source, Harwell Science and Innovation Campus, Didcot, UK
- Institute of Materials Physics, Helmholtz-Zentrum Hereon, Geesthacht, Germany
| | - Anne Bonnin
- Paul Scherrer Institut, Villigen, Switzerland
| | - Christoph Rau
- Diamond Light Source, Harwell Science and Innovation Campus, Didcot, UK
| | - Troy Margrie
- Sainsbury Wellcome Centre, University College London, London, UK
| | - Lucy Collinson
- Electron Microscopy STP, The Francis Crick Institute, London, UK
| | - Andreas T Schaefer
- Sensory Circuits and Neurotechnology Lab., The Francis Crick Institute, London, UK.
- Department of Neuroscience, Physiology and Pharmacology, University College, London, UK.
| |
Collapse
|
22
|
Li Y, Zhong Z, Zhang F, Zhao X. Artificial Intelligence-Based Human-Computer Interaction Technology Applied in Consumer Behavior Analysis and Experiential Education. Front Psychol 2022; 13:784311. [PMID: 35465552 PMCID: PMC9020504 DOI: 10.3389/fpsyg.2022.784311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Accepted: 01/10/2022] [Indexed: 11/24/2022] Open
Abstract
In the course of consumer behavior, it is necessary to study the relationship between the characteristics of psychological activities and the laws of behavior when consumers acquire and use products or services. With the development of the Internet and mobile terminals, electronic commerce (E-commerce) has become an important form of consumption for people. In order to conduct experiential education in E-commerce combined with consumer behavior, courses to understand consumer satisfaction. From the perspective of E-commerce companies, this study proposes to use artificial intelligence (AI) image recognition technology to recognize and analyze consumer facial expressions. First, it analyzes the way of human-computer interaction (HCI) in the context of E-commerce and obtains consumer satisfaction with the product through HCI technology. Then, a deep neural network (DNN) is used to predict the psychological behavior and consumer psychology of consumers to realize personalized product recommendations. In the course education of consumer behavior, it helps to understand consumer satisfaction and make a reasonable design. The experimental results show that consumers are highly satisfied with the products recommended by the system, and the degree of sanctification reaches 93.2%. It is found that the DNN model can learn consumer behavior rules during evaluation, and its prediction effect is increased by 10% compared with the traditional model, which confirms the effectiveness of the recommendation system under the DNN model. This study provides a reference for consumer psychological behavior analysis based on HCI in the context of AI, which is of great significance to help understand consumer satisfaction in consumer behavior education in the context of E-commerce.
Collapse
Affiliation(s)
- Yanmin Li
- Pan Tianshou College of Architecture, Art and Design, Ningbo University, Ningbo, China
| | - Ziqi Zhong
- Department of Management, The London School of Economics and Political Science, London, United Kingdom
| | - Fengrui Zhang
- College of Life Science, Sichuan Agricultural University, Yaan, China
| | - Xinjie Zhao
- School of Software and Microelectronics, Peking University, Beijing, China
| |
Collapse
|
23
|
An In-House Cone-Beam Tomographic Reconstruction Package for Laboratory X-ray Phase-Contrast Imaging. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12031430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Phase-contrast, and in general, multi-modal, X-ray micro-tomography is proven to be very useful for low-density, low-attention samples enabling much better contrast than its attenuation-based pendant. Therefore, it is increasingly applied in bio- and life sciences primarily dealing with such samples. Although there is a plethora of literature regarding phase-retrieval algorithms, access to implementations of those algorithms is relatively limited and very few packages combining phase-retrieval methods with the full tomographic reconstruction pipeline are available. This is especially the case for laboratory-based phase-contrast imaging typically featuring cone-beam geometry. We present here an in-house cone-beam tomographic reconstruction package for laboratory X-ray phase-contrast imaging. It covers different phase-contrast techniques and phase retrieval methods. The paper explains their implementation and integration in the filtered back projection chain. Their functionality and efficiency will be demonstrated through applications on a few dedicated samples.
Collapse
|
24
|
Reichardt M, Moller Jensen P, Andersen Dahl V, Bjorholm Dahl A, Ackermann M, Shah H, Länger F, Werlein C, Kuehnel MP, Jonigk D, Salditt T. 3D virtual histopathology of cardiac tissue from Covid-19 patients based on phase-contrast X-ray tomography. eLife 2021; 10:e71359. [PMID: 34930527 PMCID: PMC8747495 DOI: 10.7554/elife.71359] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Accepted: 12/10/2021] [Indexed: 11/29/2022] Open
Abstract
For the first time, we have used phase-contrast X-ray tomography to characterize the three-dimensional (3d) structure of cardiac tissue from patients who succumbed to Covid-19. By extending conventional histopathological examination by a third dimension, the delicate pathological changes of the vascular system of severe Covid-19 progressions can be analyzed, fully quantified and compared to other types of viral myocarditis and controls. To this end, cardiac samples with a cross-section of 3.5mm were scanned at a laboratory setup as well as at a parallel beam setup at a synchrotron radiation facility the synchrotron in a parallel beam configuration. The vascular network was segmented by a deep learning architecture suitable for 3d datasets (V-net), trained by sparse manual annotations. Pathological alterations of vessels, concerning the variation of diameters and the amount of small holes, were observed, indicative of elevated occurrence of intussusceptive angiogenesis, also confirmed by high-resolution cone beam X-ray tomography and scanning electron microscopy. Furthermore, we implemented a fully automated analysis of the tissue structure in the form of shape measures based on the structure tensor. The corresponding distributions show that the histopathology of Covid-19 differs from both influenza and typical coxsackie virus myocarditis.
Collapse
Affiliation(s)
- Marius Reichardt
- Institut für Röntgenphysik, Georg-August-Universität Göttingen, Friedrich-Hund-PlatzGöttingenGermany
| | | | | | | | - Maximilian Ackermann
- Institute of Anatomy and Cell Biology, University Medical Center of the Johannes Gutenberg-University MainzMainzGermany
| | - Harshit Shah
- Medizinische Hochschule Hannover (MHH)HannoverGermany
- Deutsches Zentrum für Lungenforschung (DZL), Hannover (BREATH)HannoverGermany
| | - Florian Länger
- Medizinische Hochschule Hannover (MHH)HannoverGermany
- Deutsches Zentrum für Lungenforschung (DZL), Hannover (BREATH)HannoverGermany
| | | | - Mark P Kuehnel
- Medizinische Hochschule Hannover (MHH)HannoverGermany
- Deutsches Zentrum für Lungenforschung (DZL), Hannover (BREATH)HannoverGermany
| | - Danny Jonigk
- Medizinische Hochschule Hannover (MHH)HannoverGermany
- Deutsches Zentrum für Lungenforschung (DZL), Hannover (BREATH)HannoverGermany
| | - Tim Salditt
- Institut für Röntgenphysik, Georg-August-Universität Göttingen, Friedrich-Hund-PlatzGöttingenGermany
| |
Collapse
|
25
|
Three-dimensional virtual histology of the human hippocampus based on phase-contrast computed tomography. Proc Natl Acad Sci U S A 2021; 118:2113835118. [PMID: 34819378 PMCID: PMC8640721 DOI: 10.1073/pnas.2113835118] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/01/2021] [Indexed: 12/17/2022] Open
Abstract
We demonstrate multiscale phase-contrast X-ray computed tomography (CT) of postmortem human brain tissue. Large tissue volumes can be covered by parallel-beam CT and combined with subcellular detail for selected regions scanned at high magnification. This has been repeated identically for a larger number of individuals, including both Alzheimer’s-diseased patients and a control group. Optimized phase retrieval, followed by automated segmentation based on machine learning, as well as feature identification and classification based on optimal transport theory, indicates a pathway from healthy to pathological structure without prior hypothesis. This study provides a blueprint for studying the cytoarchitecture of the human brain and its alterations associated with neurodegenerative diseases. We have studied the three-dimensional (3D) cytoarchitecture of the human hippocampus in neuropathologically healthy and Alzheimer’s disease (AD) individuals, based on phase-contrast X-ray computed tomography of postmortem human tissue punch biopsies. In view of recent findings suggesting a nuclear origin of AD, we target in particular the nuclear structure of the dentate gyrus (DG) granule cells. Tissue samples of 20 individuals were scanned and evaluated using a highly automated approach of measurement and analysis, combining multiscale recordings, optimized phase retrieval, segmentation by machine learning, representation of structural properties in a feature space, and classification based on the theory of optimal transport. Accordingly, we find that the prototypical transformation between a structure representing healthy granule cells and the pathological state involves a decrease in the volume of granule cell nuclei, as well as an increase in the electron density and its spatial heterogeneity. The latter can be explained by a higher ratio of heterochromatin to euchromatin. Similarly, many other structural properties can be derived from the data, reflecting both the natural polydispersity of the hippocampal cytoarchitecture between different individuals in the physiological context and the structural effects associated with AD pathology.
Collapse
|
26
|
Dreier T, Peruzzi N, Lundström U, Bech M. Improved resolution in x-ray tomography by super-resolution. APPLIED OPTICS 2021; 60:5783-5794. [PMID: 34263797 DOI: 10.1364/ao.427934] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Accepted: 05/28/2021] [Indexed: 06/13/2023]
Abstract
In this paper, super-resolution imaging is described and evaluated for x-ray tomography and is compared with standard tomography and upscaling during reconstruction. Blurring is minimized due to the negligible point spread of photon counting detectors and an electromagnetically movable micro-focus x-ray spot. Scans are acquired in high and low magnification geometry, where the latter is used to minimize penumbral blurring from the x-ray source. Sharpness and level of detail can be significantly increased in reconstructed slices to the point where the source size becomes the limiting factor. The achieved resolution of the different methods is quantified and compared using biological samples via the edge spread function, modulation transfer function, and Fourier ring correlation.
Collapse
|
27
|
Langer M, Zhang Y, Figueirinhas D, Forien JB, Mom K, Mouton C, Mokso R, Villanueva-Perez P. PyPhase - a Python package for X-ray phase imaging. JOURNAL OF SYNCHROTRON RADIATION 2021; 28:1261-1266. [PMID: 34212892 PMCID: PMC8284402 DOI: 10.1107/s1600577521004951] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Accepted: 05/11/2021] [Indexed: 06/01/2023]
Abstract
X-ray propagation-based imaging techniques are well established at synchrotron radiation and laboratory sources. However, most reconstruction algorithms for such image modalities, also known as phase-retrieval algorithms, have been developed specifically for one instrument by and for experts, making the development and diffusion of such techniques difficult. Here, PyPhase, a free and open-source package for propagation-based near-field phase reconstructions, which is distributed under the CeCILL license, is presented. PyPhase implements some of the most popular phase-retrieval algorithms in a highly modular framework supporting its deployment on large-scale computing facilities. This makes the integration, the development of new phase-retrieval algorithms, and the deployment on different computing infrastructures straightforward. Its capabilities and simplicity are presented by application to data acquired at the synchrotron source MAX IV (Lund, Sweden).
Collapse
Affiliation(s)
- Max Langer
- Univ Lyon, INSA Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621 Villeurbanne, France
| | - Yuhe Zhang
- Division of Synchrotron Radiation Research and NanoLund, Department of Physics, Lund University, SE-221 00 Lund, Sweden
| | - Diogo Figueirinhas
- Division of Packaging Logistics, Faculty of Engineering, Lund University, SE-22100 Lund, Sweden
- MAX IV Laboratory, Lund University, SE-22100 Lund, Sweden
| | | | - Kannara Mom
- Univ Lyon, INSA Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621 Villeurbanne, France
| | - Claire Mouton
- Univ Lyon, INSA Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621 Villeurbanne, France
| | - Rajmund Mokso
- Division of Solid Mechanics, Faculty of Engineering, Lund University, SE-22100 Lund, Sweden
| | - Pablo Villanueva-Perez
- Division of Synchrotron Radiation Research and NanoLund, Department of Physics, Lund University, SE-221 00 Lund, Sweden
| |
Collapse
|
28
|
Vassholz M, Hoeppe HP, Hagemann J, Rosselló JM, Osterhoff M, Mettin R, Kurz T, Schropp A, Seiboth F, Schroer CG, Scholz M, Möller J, Hallmann J, Boesenberg U, Kim C, Zozulya A, Lu W, Shayduk R, Schaffer R, Madsen A, Salditt T. Pump-probe X-ray holographic imaging of laser-induced cavitation bubbles with femtosecond FEL pulses. Nat Commun 2021; 12:3468. [PMID: 34103498 PMCID: PMC8187368 DOI: 10.1038/s41467-021-23664-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Accepted: 04/27/2021] [Indexed: 11/24/2022] Open
Abstract
Cavitation bubbles can be seeded from a plasma following optical breakdown, by focusing an intense laser in water. The fast dynamics are associated with extreme states of gas and liquid, especially in the nascent state. This offers a unique setting to probe water and water vapor far-from equilibrium. However, current optical techniques cannot quantify these early states due to contrast and resolution limitations. X-ray holography with single X-ray free-electron laser pulses has now enabled a quasi-instantaneous high resolution structural probe with contrast proportional to the electron density of the object. In this work, we demonstrate cone-beam holographic flash imaging of laser-induced cavitation bubbles in water with nanofocused X-ray free-electron laser pulses. We quantify the spatial and temporal pressure distribution of the shockwave surrounding the expanding cavitation bubble at time delays shortly after seeding and compare the results to numerical simulations.
Collapse
Affiliation(s)
- M Vassholz
- Institut für Röntgenphysik, Georg-August-Universität Göttingen, Göttingen, Germany
| | - H P Hoeppe
- Institut für Röntgenphysik, Georg-August-Universität Göttingen, Göttingen, Germany
| | - J Hagemann
- CXNS - Center for X-ray and Nano Science, Deutsches Elektronen-Synchrotron DESY, Hamburg, Germany
| | - J M Rosselló
- Drittes Physikalisches Institut, Georg-August-Universität Göttingen, Göttingen, Germany
| | - M Osterhoff
- Institut für Röntgenphysik, Georg-August-Universität Göttingen, Göttingen, Germany
| | - R Mettin
- Drittes Physikalisches Institut, Georg-August-Universität Göttingen, Göttingen, Germany
| | - T Kurz
- Drittes Physikalisches Institut, Georg-August-Universität Göttingen, Göttingen, Germany
| | - A Schropp
- CXNS - Center for X-ray and Nano Science, Deutsches Elektronen-Synchrotron DESY, Hamburg, Germany
| | - F Seiboth
- CXNS - Center for X-ray and Nano Science, Deutsches Elektronen-Synchrotron DESY, Hamburg, Germany
| | - C G Schroer
- CXNS - Center for X-ray and Nano Science, Deutsches Elektronen-Synchrotron DESY, Hamburg, Germany
- Department Physik, Universität Hamburg, Hamburg, Germany
| | - M Scholz
- European X-Ray Free-Electron Laser Facility, Schenefeld, Germany
| | - J Möller
- European X-Ray Free-Electron Laser Facility, Schenefeld, Germany
| | - J Hallmann
- European X-Ray Free-Electron Laser Facility, Schenefeld, Germany
| | - U Boesenberg
- European X-Ray Free-Electron Laser Facility, Schenefeld, Germany
| | - C Kim
- European X-Ray Free-Electron Laser Facility, Schenefeld, Germany
| | - A Zozulya
- European X-Ray Free-Electron Laser Facility, Schenefeld, Germany
| | - W Lu
- European X-Ray Free-Electron Laser Facility, Schenefeld, Germany
| | - R Shayduk
- European X-Ray Free-Electron Laser Facility, Schenefeld, Germany
| | - R Schaffer
- European X-Ray Free-Electron Laser Facility, Schenefeld, Germany
| | - A Madsen
- European X-Ray Free-Electron Laser Facility, Schenefeld, Germany
| | - T Salditt
- Institut für Röntgenphysik, Georg-August-Universität Göttingen, Göttingen, Germany.
| |
Collapse
|
29
|
Hagemann J, Vassholz M, Hoeppe H, Osterhoff M, Rosselló JM, Mettin R, Seiboth F, Schropp A, Möller J, Hallmann J, Kim C, Scholz M, Boesenberg U, Schaffer R, Zozulya A, Lu W, Shayduk R, Madsen A, Schroer CG, Salditt T. Single-pulse phase-contrast imaging at free-electron lasers in the hard X-ray regime. JOURNAL OF SYNCHROTRON RADIATION 2021; 28:52-63. [PMID: 33399552 PMCID: PMC7842230 DOI: 10.1107/s160057752001557x] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Accepted: 11/24/2020] [Indexed: 05/31/2023]
Abstract
X-ray free-electron lasers (XFELs) have opened up unprecedented opportunities for time-resolved nano-scale imaging with X-rays. Near-field propagation-based imaging, and in particular near-field holography (NFH) in its high-resolution implementation in cone-beam geometry, can offer full-field views of a specimen's dynamics captured by single XFEL pulses. To exploit this capability, for example in optical-pump/X-ray-probe imaging schemes, the stochastic nature of the self-amplified spontaneous emission pulses, i.e. the dynamics of the beam itself, presents a major challenge. In this work, a concept is presented to address the fluctuating illumination wavefronts by sampling the configuration space of SASE pulses before an actual recording, followed by a principal component analysis. This scheme is implemented at the MID (Materials Imaging and Dynamics) instrument of the European XFEL and time-resolved NFH is performed using aberration-corrected nano-focusing compound refractive lenses. Specifically, the dynamics of a micro-fluidic water-jet, which is commonly used as sample delivery system at XFELs, is imaged. The jet exhibits rich dynamics of droplet formation in the break-up regime. Moreover, pump-probe imaging is demonstrated using an infrared pulsed laser to induce cavitation and explosion of the jet.
Collapse
Affiliation(s)
- Johannes Hagemann
- Deutsches Elektronen Synchrotron – DESY, Notkestraße 85, 22607 Hamburg, Germany
| | - Malte Vassholz
- Institute for X-ray Physics, University of Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| | - Hannes Hoeppe
- Institute for X-ray Physics, University of Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| | - Markus Osterhoff
- Institute for X-ray Physics, University of Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| | - Juan M. Rosselló
- Third Institute of Physics, University of Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| | - Robert Mettin
- Third Institute of Physics, University of Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| | - Frank Seiboth
- Deutsches Elektronen Synchrotron – DESY, Notkestraße 85, 22607 Hamburg, Germany
| | - Andreas Schropp
- Deutsches Elektronen Synchrotron – DESY, Notkestraße 85, 22607 Hamburg, Germany
| | - Johannes Möller
- European X-ray Free-Electron Laser Facility, Holzkoppel 4, 22869 Schenefeld, Germany
| | - Jörg Hallmann
- European X-ray Free-Electron Laser Facility, Holzkoppel 4, 22869 Schenefeld, Germany
| | - Chan Kim
- European X-ray Free-Electron Laser Facility, Holzkoppel 4, 22869 Schenefeld, Germany
| | - Markus Scholz
- European X-ray Free-Electron Laser Facility, Holzkoppel 4, 22869 Schenefeld, Germany
| | - Ulrike Boesenberg
- European X-ray Free-Electron Laser Facility, Holzkoppel 4, 22869 Schenefeld, Germany
| | - Robert Schaffer
- European X-ray Free-Electron Laser Facility, Holzkoppel 4, 22869 Schenefeld, Germany
| | - Alexey Zozulya
- European X-ray Free-Electron Laser Facility, Holzkoppel 4, 22869 Schenefeld, Germany
| | - Wei Lu
- European X-ray Free-Electron Laser Facility, Holzkoppel 4, 22869 Schenefeld, Germany
| | - Roman Shayduk
- European X-ray Free-Electron Laser Facility, Holzkoppel 4, 22869 Schenefeld, Germany
| | - Anders Madsen
- European X-ray Free-Electron Laser Facility, Holzkoppel 4, 22869 Schenefeld, Germany
| | - Christian G. Schroer
- Deutsches Elektronen Synchrotron – DESY, Notkestraße 85, 22607 Hamburg, Germany
- Department Physik, Universität Hamburg, Luruper Chaussee 149, 22761 Hamburg, Germany
| | - Tim Salditt
- Institute for X-ray Physics, University of Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| |
Collapse
|
30
|
Frohn J, Pinkert-Leetsch D, Missbach-Güntner J, Reichardt M, Osterhoff M, Alves F, Salditt T. 3D virtual histology of human pancreatic tissue by multiscale phase-contrast X-ray tomography. JOURNAL OF SYNCHROTRON RADIATION 2020; 27:1707-1719. [PMID: 33147198 PMCID: PMC7642968 DOI: 10.1107/s1600577520011327] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Accepted: 08/18/2020] [Indexed: 05/05/2023]
Abstract
A multiscale three-dimensional (3D) virtual histology approach is presented, based on two configurations of propagation phase-contrast X-ray tomography, which have been implemented in close proximity at the GINIX endstation at the beamline P10/PETRA III (DESY, Hamburg, Germany). This enables the 3D reconstruction of characteristic morphological features of human pancreatic normal and tumor tissue, as obtained from cancer surgery, first in the form of a large-scale overview by parallel-beam illumination, followed by a zoom into a region-of-interest based on zoom tomography using a Kirkpatrick-Baez mirror with additional waveguide optics. To this end 1 mm punch biopsies of the tissue were taken. In the parallel tomography, a volumetric throughput on the order of 0.01 mm3 s-1 was achieved, while maintaining the ability to segment isolated cells. With a continuous rotation during the scan, a total acquisition time of less than 2 min was required for a full tomographic scan. Using the combination of both setups, islets of Langerhans, a three-dimensional cluster of cells in the endocrine part of the pancreas, could be located. Cells in such an islet were segmented and visualized in 3D. Further, morphological alterations of tumorous tissue of the pancreas were characterized. To this end, the anisotropy parameter Ω, based on intensity gradients, was used in order to quantify the presence of collagen fibers within the entire biopsy specimen. This proof-of-concept experiment of the multiscale approach on human pancreatic tissue paves the way for future 3D virtual pathology.
Collapse
Affiliation(s)
- Jasper Frohn
- Institute for X-ray Physics, Universität Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| | - Diana Pinkert-Leetsch
- Institute of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Robert Koch Strasse 40, 37075 Göttingen, Germany
- Max Planck Institute for Experimental Medicine, Group of Translational Molecular Imaging, Hermann-Rein-Strasse 3, 37075 Göttingen, Germany
| | - Jeannine Missbach-Güntner
- Institute of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Robert Koch Strasse 40, 37075 Göttingen, Germany
| | - Marius Reichardt
- Institute for X-ray Physics, Universität Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| | - Markus Osterhoff
- Institute for X-ray Physics, Universität Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| | - Frauke Alves
- Institute of Diagnostic and Interventional Radiology, University Medical Center Göttingen, Robert Koch Strasse 40, 37075 Göttingen, Germany
- Max Planck Institute for Experimental Medicine, Group of Translational Molecular Imaging, Hermann-Rein-Strasse 3, 37075 Göttingen, Germany
- Clinic of Hematology and Medical Oncology, University Medical Center Göttingen, Robert Koch Strase 40, 37075 Göttingen, Germany
| | - Tim Salditt
- Institute for X-ray Physics, Universität Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
- Multiscale Bioimaging: From Molecular Machines to Networks of Excitable Cells (MBExC), University Medical Center Göttingen, Robert Koch Strase 40, 37075 Göttingen, Germany
| |
Collapse
|
31
|
X-Ray Structural Analysis of Single Adult Cardiomyocytes: Tomographic Imaging and Microdiffraction. Biophys J 2020; 119:1309-1323. [PMID: 32937109 PMCID: PMC7567981 DOI: 10.1016/j.bpj.2020.08.019] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 08/06/2020] [Accepted: 08/17/2020] [Indexed: 02/08/2023] Open
Abstract
We present a multiscale imaging approach to characterize the structure of isolated adult murine cardiomyocytes based on a combination of full-field three-dimensional coherent x-ray imaging and scanning x-ray diffraction. Using these modalities, we probe the structure from the molecular to the cellular scale. Holographic projection images on freeze-dried cells have been recorded using highly coherent and divergent x-ray waveguide radiation. Phase retrieval and tomographic reconstruction then yield the three-dimensional electron density distribution with a voxel size below 50 nm. In the reconstruction volume, myofibrils, sarcomeric organization, and mitochondria can be visualized and quantified within a single cell without sectioning. Next, we use microfocusing optics by compound refractive lenses to probe the diffraction signal of the actomyosin lattice. Comparison between recordings of chemically fixed and untreated, living cells indicate that the characteristic lattice distances shrink by ∼10% upon fixation.
Collapse
|
32
|
Eckermann M, Peruzzi N, Frohn J, Bech M, Englund E, Veress B, Salditt T, Dahlin LB, Ohlsson B. 3d phase-contrast nanotomography of unstained human skin biopsies may identify morphological differences in the dermis and epidermis between subjects. Skin Res Technol 2020; 27:316-323. [PMID: 33022848 PMCID: PMC8246570 DOI: 10.1111/srt.12974] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Accepted: 09/07/2020] [Indexed: 12/13/2022]
Abstract
BACKGROUND Enteric neuropathy is described in most patients with gastrointestinal dysmotility and may be found together with reduced intraepidermal nerve fiber density (IENFD). The aim of this pilot study was to assess whether three-dimensional (3d) imaging of skin biopsies could be used to examine various tissue components in patients with gastrointestinal dysmotility. MATERIAL AND METHODS Four dysmotility patients of different etiology and two healthy volunteers were included. From each subject, two 3-mm punch skin biopsies were stained with antibodies against protein gene product 9.5 or evaluated as a whole with two X-ray phase-contrast computed tomography (CT) setups, a laboratory µCT setup and a dedicated synchrotron radiation nanoCT end-station. RESULTS Two patients had reduced IENFD, and two normal IENFD, compared with controls. µCT and X-ray phase-contrast holographic nanotomography scanned whole tissue specimens, with optional high-resolution scans revealing delicate structures, without differentiation of various fibers and cells. Irregular architecture of dermal fibers was observed in the patient with Ehlers-Danlos syndrome and the patient with idiopathic dysmotility showed an abundance of mesenchymal ground substance. CONCLUSIONS 3d phase-contrast tomographic imaging may be useful to illustrate traits of connective tissue dysfunction in various organs and to demonstrate whether disorganized dermal fibers could explain organ dysfunction.
Collapse
Affiliation(s)
- Marina Eckermann
- Institute for X-Ray Physics, University of Göttingen, Göttingen, Germany.,Cluster of Excellence "Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells" (MBExC), University of Göttingen, Göttingen, Germany
| | - Niccolò Peruzzi
- Medical Radiation Physics, Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Jasper Frohn
- Institute for X-Ray Physics, University of Göttingen, Göttingen, Germany
| | - Martin Bech
- Medical Radiation Physics, Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Elisabet Englund
- Division of Oncology and Pathology, Skane University Hospital, Lund University, Lund, Sweden
| | - Béla Veress
- Department of Pathology, Skåne University Hospital, Malmö, Sweden
| | - Tim Salditt
- Institute for X-Ray Physics, University of Göttingen, Göttingen, Germany.,Cluster of Excellence "Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells" (MBExC), University of Göttingen, Göttingen, Germany
| | - Lars B Dahlin
- Department of Translational Medicine - Hand Surgery, Lund University, Malmö, Sweden.,Department of Hand Surgery, Skåne University Hospital, Malmö, Sweden
| | - Bodil Ohlsson
- Department of Internal Medicine, Skåne University Hospital, Lund University, Malmö, Sweden
| |
Collapse
|
33
|
Peruzzi N, Veress B, Dahlin LB, Salditt T, Andersson M, Eckermann M, Frohn J, Robisch AL, Bech M, Ohlsson B. 3D analysis of the myenteric plexus of the human bowel by X-ray phase-contrast tomography - a future method? Scand J Gastroenterol 2020; 55:1261-1267. [PMID: 32907418 DOI: 10.1080/00365521.2020.1815079] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVES Light microscopical analysis in two dimensions, combined with immunohistochemistry, is presently the gold standard to describe the enteric nervous system (ENS). Our aim was to assess the usefulness of three-dimensional (3D) imaging by X-ray phase-contrast tomography in evaluating the ENS of the human bowel. MATERIAL AND METHODS Myenteric ganglia were identified in full-thickness biopsies of the ileum and colon by hematoxylin & eosin staining. A1-mm biopsy punch was taken from the paraffin blocks and placed into a Kapton® tube for subsequent tomographic investigation. The samples were scanned, without further preparation, using phase-contrast tomography at two different scales: overview scans (performed with laboratory setups), which allowed localization of the nervous tissue (∼1µm effective voxel size); and high-resolution scans (performed with a synchrotron endstation), which imaged localized regions of 320x320x320 µm3 (176 nm effective voxel size). RESULTS The contrast allowed us to follow the shape and the size changes of the ganglia, as well as to study their cellular components together with the cells and cellular projections of the periganglional space. Furthermore, it was possible to show the 3D network of the myenteric plexus and to quantify its volume within the samples. CONCLUSIONS Phase-contrast X-ray tomography can be applied for volume analyses of the human ENS and to study tissue components in unstained paraffin-embedded tissue biopsies. This technique could potentially be used to study disease mechanisms, and to compare healthy and diseased tissues in clinical research.
Collapse
Affiliation(s)
- Niccolò Peruzzi
- Division of Medical Radiation Physics, Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Béla Veress
- Department of Pathology, Skåne University Hospital, Malmö, Sweden
| | - Lars B Dahlin
- Department of Translational Medicine - Hand Surgery, Lund University, Malmö, Sweden.,Department of Hand Surgery, Skåne University Hospital, Malmö, Sweden
| | - Tim Salditt
- Institute for X-Ray Physics, University of Göttingen, Göttingen, Germany.,Cluster of Excellence "Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells" (MBExC), University of Göttingen, Germany
| | - Mariam Andersson
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, Lyngby, Denmark.,Danish Research Centre for Magnetic Resonance (DRCMR), Center for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark
| | - Marina Eckermann
- Institute for X-Ray Physics, University of Göttingen, Göttingen, Germany.,Cluster of Excellence "Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells" (MBExC), University of Göttingen, Germany
| | - Jasper Frohn
- Institute for X-Ray Physics, University of Göttingen, Göttingen, Germany
| | - Anna-Lena Robisch
- Institute for X-Ray Physics, University of Göttingen, Göttingen, Germany
| | - Martin Bech
- Division of Medical Radiation Physics, Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Bodil Ohlsson
- Lund University, Skåne University Hospital, Department of Internal Medicine, Malmö, Sweden
| |
Collapse
|
34
|
Eckermann M, Frohn J, Reichardt M, Osterhoff M, Sprung M, Westermeier F, Tzankov A, Werlein C, Kühnel M, Jonigk D, Salditt T. 3D virtual pathohistology of lung tissue from Covid-19 patients based on phase contrast X-ray tomography. eLife 2020; 9:e60408. [PMID: 32815517 PMCID: PMC7473770 DOI: 10.7554/elife.60408] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Accepted: 08/17/2020] [Indexed: 01/25/2023] Open
Abstract
We present a three-dimensional (3D) approach for virtual histology and histopathology based on multi-scale phase contrast x-ray tomography, and use this to investigate the parenchymal architecture of unstained lung tissue from patients who succumbed to Covid-19. Based on this first proof-of-concept study, we propose multi-scale phase contrast x-ray tomography as a tool to unravel the pathophysiology of Covid-19, extending conventional histology by a third dimension and allowing for full quantification of tissue remodeling. By combining parallel and cone beam geometry, autopsy samples with a maximum cross section of 8 mm are scanned and reconstructed at a resolution and image quality, which allows for the segmentation of individual cells. Using the zoom capability of the cone beam geometry, regions-of-interest are reconstructed with a minimum voxel size of 167 nm. We exemplify the capability of this approach by 3D visualization of diffuse alveolar damage (DAD) with its prominent hyaline membrane formation, by mapping the 3D distribution and density of lymphocytes infiltrating the tissue, and by providing histograms of characteristic distances from tissue interior to the closest air compartment.
Collapse
Affiliation(s)
- Marina Eckermann
- Institut für Röntgenphysik, Georg-August-UniversitätGöttingenGermany
- Cluster of Excellence 'Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells' (MBExC), University of GöttingenGöttingenGermany
| | - Jasper Frohn
- Institut für Röntgenphysik, Georg-August-UniversitätGöttingenGermany
| | - Marius Reichardt
- Institut für Röntgenphysik, Georg-August-UniversitätGöttingenGermany
| | - Markus Osterhoff
- Institut für Röntgenphysik, Georg-August-UniversitätGöttingenGermany
| | | | | | - Alexandar Tzankov
- Institut für Medizinische Genetik und Pathologie, Universitätsspital BaselBaselSwitzerland
| | - Christopher Werlein
- Medizinische Hochschule Hannover (MHH)HannoverGermany
- Deutsches Zentrum für Lungenforschung (DZL)Hannover (BREATH)Germany
| | - Mark Kühnel
- Medizinische Hochschule Hannover (MHH)HannoverGermany
- Deutsches Zentrum für Lungenforschung (DZL)Hannover (BREATH)Germany
| | - Danny Jonigk
- Medizinische Hochschule Hannover (MHH)HannoverGermany
- Deutsches Zentrum für Lungenforschung (DZL)Hannover (BREATH)Germany
| | - Tim Salditt
- Institut für Röntgenphysik, Georg-August-UniversitätGöttingenGermany
- Cluster of Excellence 'Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells' (MBExC), University of GöttingenGöttingenGermany
| |
Collapse
|
35
|
Matsuda K, Yasumoto M, Akter N, Misawa M, Aguilar JC, Suzuki Y, Takeuchi A, Hibino K, Rehman S, Roy M. Hard x-ray phase-contrast microscopy using a Gabor hologram without a zero-order term. APPLIED OPTICS 2020; 59:5918-5923. [PMID: 32672734 DOI: 10.1364/ao.393008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2020] [Accepted: 06/01/2020] [Indexed: 06/11/2023]
Abstract
In order to achieve a nanometer-scale resolution in an x-ray microscopy system, a Gabor-type hologram was produced by eliminating the zero-order term of the object diffraction pattern. In this system, a Fresnel zone plate was used for strong illumination of an object, and the zero-order diffraction was physically eliminated by a center stop. An accurate phase plate of π/2 in the Zernike method was numerically created, and the phase-contrast image was realized. The theoretical resolution was 19.8 nm. We proved that a gold nanocube with a size of 50 nm can be reconstructed with the predicted resolution.
Collapse
|
36
|
Reichardt M, Frohn J, Khan A, Alves F, Salditt T. Multi-scale X-ray phase-contrast tomography of murine heart tissue. BIOMEDICAL OPTICS EXPRESS 2020; 11:2633-2651. [PMID: 32499949 PMCID: PMC7249829 DOI: 10.1364/boe.386576] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 03/12/2020] [Accepted: 03/18/2020] [Indexed: 05/07/2023]
Abstract
The spatial organization of cardiac muscle tissue exhibits a complex structure on multiple length scales, from the sarcomeric unit to the whole organ. Here we demonstrate a multi-scale three-dimensional imaging (3d) approach with three levels of magnification, based on synchrotron X-ray phase contrast tomography. Whole mouse hearts are scanned in an undulator beam, which is first focused and then broadened by divergence. Regions-of-interest of the hearts are scanned in parallel beam as well as a biopsy by magnified cone beam geometry using a X-ray waveguide optic. Data is analyzed in terms of orientation, anisotropy and the sarcomeric periodicity via a local Fourier transformation.
Collapse
Affiliation(s)
- Marius Reichardt
- Gerorg-August-University, Institute for x-ray Physics, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| | - Jasper Frohn
- Gerorg-August-University, Institute for x-ray Physics, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| | - Amara Khan
- Max Planck Institute for Experimental Medicine, Group of Translational Molecular Imaging, German Hermann-Rein-Straße 3, 37075 Göttingen, Germany
| | - Frauke Alves
- Max Planck Institute for Experimental Medicine, Group of Translational Molecular Imaging, German Hermann-Rein-Straße 3, 37075 Göttingen, Germany
- University Medical Center Göttingen, Clinic of Hematology and Medical Oncology, Robert-Koch-Straße 40, 37075 Göttingen, Germany
- University Medical Center Göttingen, Institute for Diagnostic and Interventional Radiology, Robert-Koch-Straße 40, 37075 Göttingen, Germany
| | - Tim Salditt
- Gerorg-August-University, Institute for x-ray Physics, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| |
Collapse
|