1
|
Wearable Motion Capture: Reconstructing and Predicting 3D Human Poses From Wearable Sensors. IEEE J Biomed Health Inform 2023; 27:5345-5356. [PMID: 37665702 DOI: 10.1109/jbhi.2023.3311448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/06/2023]
Abstract
Reconstructing and predicting 3D human walking poses in unconstrained measurement environments have the potential to use for health monitoring systems for people with movement disabilities by assessing progression after treatments and providing information for assistive device controls. The latest pose estimation algorithms utilize motion capture systems, which capture data from IMU sensors and third-person view cameras. However, third-person views are not always possible for outpatients alone. Thus, we propose the wearable motion capture problem of reconstructing and predicting 3D human poses from the wearable IMU sensors and wearable cameras, which aids clinicians' diagnoses on patients out of clinics. To solve this problem, we introduce a novel Attention-Oriented Recurrent Neural Network (AttRNet) that contains a sensor-wise attention-oriented recurrent encoder, a reconstruction module, and a dynamic temporal attention-oriented recurrent decoder, to reconstruct the 3D human pose over time and predict the 3D human poses at the following time steps. To evaluate our approach, we collected a new WearableMotionCapture dataset using wearable IMUs and wearable video cameras, along with the musculoskeletal joint angle ground truth. The proposed AttRNet shows high accuracy on the new lower-limb WearableMotionCapture dataset, and it also outperforms the state-of-the-art methods on two public full-body pose datasets: DIP-IMU and TotalCaputre.
Collapse
|
2
|
Conversion of Upper-Limb Inertial Measurement Unit Data to Joint Angles: A Systematic Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:6535. [PMID: 37514829 PMCID: PMC10386307 DOI: 10.3390/s23146535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 07/11/2023] [Accepted: 07/17/2023] [Indexed: 07/30/2023]
Abstract
Inertial measurement units (IMUs) have become the mainstay in human motion evaluation outside of the laboratory; however, quantification of 3-dimensional upper limb motion using IMUs remains challenging. The objective of this systematic review is twofold. Firstly, to evaluate computational methods used to convert IMU data to joint angles in the upper limb, including for the scapulothoracic, humerothoracic, glenohumeral, and elbow joints; and secondly, to quantify the accuracy of these approaches when compared to optoelectronic motion analysis. Fifty-two studies were included. Maximum joint motion measurement accuracy from IMUs was achieved using Euler angle decomposition and Kalman-based filters. This resulted in differences between IMU and optoelectronic motion analysis of 4° across all degrees of freedom of humerothoracic movement. Higher accuracy has been achieved at the elbow joint with functional joint axis calibration tasks and the use of kinematic constraints on gyroscope data, resulting in RMS errors between IMU and optoelectronic motion for flexion-extension as low as 2°. For the glenohumeral joint, 3D joint motion has been described with RMS errors of 6° and higher. In contrast, scapulothoracic joint motion tracking yielded RMS errors in excess of 10° in the protraction-retraction and anterior-posterior tilt direction. The findings of this study demonstrate high-quality 3D humerothoracic and elbow joint motion measurement capability using IMUs and underscore the challenges of skin motion artifacts in scapulothoracic and glenohumeral joint motion analysis. Future studies ought to implement functional joint axis calibrations, and IMU-based scapula locators to address skin motion artifacts at the scapula, and explore the use of artificial neural networks and data-driven approaches to directly convert IMU data to joint angles.
Collapse
|
3
|
Self-Calibrating Magnetometer-Free Inertial Motion Tracking of 2-DoF Joints. SENSORS (BASEL, SWITZERLAND) 2022; 22:9850. [PMID: 36560219 PMCID: PMC9785932 DOI: 10.3390/s22249850] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/05/2022] [Accepted: 12/12/2022] [Indexed: 06/17/2023]
Abstract
Human motion analysis using inertial measurement units (IMUs) has recently been shown to provide accuracy similar to the gold standard, optical motion capture, but at lower costs and while being less restrictive and time-consuming. However, IMU-based motion analysis requires precise knowledge of the orientations in which the sensors are attached to the body segments. This knowledge is commonly obtained via time-consuming and error-prone anatomical calibration based on precisely defined poses or motions. In the present work, we propose a self-calibrating approach for magnetometer-free joint angle tracking that is suitable for joints with two degrees of freedom (DoF), such as the elbow, ankle, and metacarpophalangeal finger joints. The proposed methods exploit kinematic constraints in the angular rates and the relative orientations to simultaneously identify the joint axes and the heading offset. The experimental evaluation shows that the proposed methods are able to estimate plausible and consistent joint axes from just ten seconds of arbitrary elbow joint motion. Comparison with optical motion capture shows that the proposed methods yield joint angles with similar accuracy as a conventional IMU-based method while being much less restrictive. Therefore, the proposed methods improve the practical usability of IMU-based motion tracking in many clinical and biomedical applications.
Collapse
|
4
|
A database of physical therapy exercises with variability of execution collected by wearable sensors. Sci Data 2022; 9:266. [PMID: 35661743 PMCID: PMC9166805 DOI: 10.1038/s41597-022-01387-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Accepted: 05/12/2022] [Indexed: 11/10/2022] Open
Abstract
This document introduces the PHYTMO database, which contains data from physical therapies recorded with inertial sensors, including information from an optical reference system. PHYTMO includes the recording of 30 volunteers, aged between 20 and 70 years old. A total amount of 6 exercises and 3 gait variations were recorded. The volunteers performed two series with a minimum of 8 repetitions in each one. PHYTMO includes magneto-inertial data, together with a highly accurate location and orientation in the 3D space provided by the optical system. The files were stored in CSV format to ensure its usability. The aim of this dataset is the availability of data for two main purposes: the analysis of techniques for the identification and evaluation of exercises using inertial sensors and the validation of inertial sensor-based algorithms for human motion monitoring. Furthermore, the database stores enough data to apply Machine Learning-based algorithms. The participants' age range is large enough to establish age-based metrics for the exercises evaluation or the study of differences in motions between different groups.
Collapse
|
5
|
Validation of wearable inertial sensor-based gait analysis system for measurement of spatiotemporal parameters and lower extremity joint kinematics in sagittal plane. Proc Inst Mech Eng H 2022; 236:686-696. [DOI: 10.1177/09544119211072971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Wearable inertial sensor-based motion analysis systems are promising alternatives to standard camera-based motion capture systems for the measurement of gait parameters and joint kinematics. These wearable sensors, unlike camera-based gold standard systems, find usefulness in outdoor natural environment along with confined indoor laboratory-based environment due to miniature size and wireless data transmission. This study reports validation of our developed (i-Sens) wearable motion analysis system against standard motion capture system. Gait analysis was performed at self-selected speed on non-disabled volunteers in indoor ( n = 15) and outdoor ( n = 8) environments. Two i-Sens units were placed at the level of knee and hip along with passive markers (for indoor study only) for simultaneous 3D motion capture using a motion capture system. Mean absolute percentage error (MAPE) was computed for spatiotemporal parameters from the i-Sens system versus the motion capture system as a true reference. Mean and standard deviation of kinematic data for a gait cycle were plotted for both systems against normative data. Joint kinematics data were analyzed to compute the root mean squared error (RMSE) and Pearson’s correlation coefficient. Kinematic plots indicate a high degree of accuracy of the i-Sens system with the reference system. Excellent positive correlation was observed between the two systems in terms of hip and knee joint angles (Indoor: hip 3.98° ± 1.03°, knee 6.48° ± 1.91°, Outdoor: hip 3.94° ± 0.78°, knee 5.82° ± 0.99°) with low RMSE. Reliability characteristics (defined using standard statistical thresholds of MAPE) of stride length, cadence, walking speed in both outdoor and indoor environment were well within the “Good” category. The i-Sens system has emerged as a potentially cost-effective, valid, accurate, and reliable alternative to expensive, standard motion capture systems for gait analysis. Further clinical trials using the i-Sens system are warranted on participants across different age groups.
Collapse
|
6
|
Body-Worn IMU-Based Human Hip and Knee Kinematics Estimation during Treadmill Walking. SENSORS 2022; 22:s22072544. [PMID: 35408159 PMCID: PMC9003309 DOI: 10.3390/s22072544] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 03/14/2022] [Accepted: 03/16/2022] [Indexed: 12/22/2022]
Abstract
Traditionally, inertial measurement unit (IMU)-based human joint angle estimation techniques are evaluated for general human motion where human joints explore all of their degrees of freedom. Pure human walking, in contrast, limits the motion of human joints and may lead to unobservability conditions that confound magnetometer-free IMU-based methods. This work explores the unobservability conditions emergent during human walking and expands upon a previous IMU-based method for the human knee to also estimate human hip angles relative to an assumed vertical datum. The proposed method is evaluated (N=12) in a human subject study and compared against an optical motion capture system. Accuracy of human knee flexion/extension angle (7.87∘ absolute root mean square error (RMSE)), hip flexion/extension angle (3.70∘ relative RMSE), and hip abduction/adduction angle (4.56∘ relative RMSE) during walking are similar to current state-of-the-art self-calibrating IMU methods that use magnetometers. Larger errors of hip internal/external rotation angle (6.27∘ relative RMSE) are driven by IMU heading drift characteristic of magnetometer-free approaches and non-hinge kinematics of the hip during gait, amongst other error sources. One of these sources of error, soft tissue perturbations during gait, is explored further in the context of knee angle estimation and it was observed that the IMU method may overestimate the angle during stance and underestimate the angle during swing. The presented method and results provide a novel combination of observability considerations, heuristic correction methods, and validation techniques to magnetic-blind, kinematic-only IMU-based skeletal pose estimation during human tasks with degenerate kinematics (e.g., straight line walking).
Collapse
|
7
|
In-vitro validation of inertial-sensor-to-bone alignment. J Biomech 2021; 128:110781. [PMID: 34628197 DOI: 10.1016/j.jbiomech.2021.110781] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 09/24/2021] [Accepted: 09/27/2021] [Indexed: 11/24/2022]
Abstract
A major shortcoming in kinematic estimation using skin-attached inertial sensors is the alignment of sensor-embedded and segment-embedded coordinate systems. Only a correct alignment results in clinically relevant kinematics. Model-based inertial-sensor-to-bone alignment methods relate inertial sensor measurements with a model of the joint. Therefore, they do not rely on properly executed calibration movements or a correct sensor placement. However, it is unknown how accurate such model-based methods align the sensor axes and the underlying segment-embedded axes, as defined by clinical definitions. Also, validation of the alignment models is challenging, since an optical motion capture ground truth can be prone to disturbances from soft tissue movement, orientation estimation and manual palpation errors. We present an anatomical tibiofemoral ground truth on an unloaded cadaveric measurement set-up that intrinsically overcomes these disturbances. Additionally, we validate existing model-based alignment strategies. Modeling the degrees of freedom leads to the identification of rotation axes. However, there is no reason why these axes would align with the segment-embedded axes. Relative inertial-sensor orientation information and rich arbitrary movements showed to aid in identifying the underlying joint axes. The first dominant sagittal rotation axis aligned sufficiently well with the underlying segment-embedded reference. The estimated axes that relate to secondary kinematics tend to deviate from the underlying segment-embedded axes as much as their expected range of motion around the axes. In order to interpret the secondary kinematics, the alignment model should more closely match the biomechanics of the joint.
Collapse
|
8
|
Custom IMU-Based Wearable System for Robust 2.4 GHz Wireless Human Body Parts Orientation Tracking and 3D Movement Visualization on an Avatar. SENSORS 2021; 21:s21196642. [PMID: 34640961 PMCID: PMC8512038 DOI: 10.3390/s21196642] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 09/30/2021] [Accepted: 09/30/2021] [Indexed: 02/06/2023]
Abstract
Recent studies confirm the applicability of Inertial Measurement Unit (IMU)-based systems for human motion analysis. Notwithstanding, high-end IMU-based commercial solutions are yet too expensive and complex to democratize their use among a wide range of potential users. Less featured entry-level commercial solutions are being introduced in the market, trying to fill this gap, but still present some limitations that need to be overcome. At the same time, there is a growing number of scientific papers using not commercial, but custom do-it-yourself IMU-based systems in medical and sports applications. Even though these solutions can help to popularize the use of this technology, they have more limited features and the description on how to design and build them from scratch is yet too scarce in the literature. The aim of this work is two-fold: (1) Proving the feasibility of building an affordable custom solution aimed at simultaneous multiple body parts orientation tracking; while providing a detailed bottom-up description of the required hardware, tools, and mathematical operations to estimate and represent 3D movement in real-time. (2) Showing how the introduction of a custom 2.4 GHz communication protocol including a channel hopping strategy can address some of the current communication limitations of entry-level commercial solutions. The proposed system can be used for wireless real-time human body parts orientation tracking with up to 10 custom sensors, at least at 50 Hz. In addition, it provides a more reliable motion data acquisition in Bluetooth and Wi-Fi crowded environments, where the use of entry-level commercial solutions might be unfeasible. This system can be used as a groundwork for developing affordable human motion analysis solutions that do not require an accurate kinematic analysis.
Collapse
|
9
|
Reference in-vitro dataset for inertial-sensor-to-bone alignment applied to the tibiofemoral joint. Sci Data 2021; 8:208. [PMID: 34354084 PMCID: PMC8342472 DOI: 10.1038/s41597-021-00995-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Accepted: 07/09/2021] [Indexed: 11/12/2022] Open
Abstract
Skin-attached inertial sensors are increasingly used for kinematic analysis. However, their ability to measure outside-lab can only be exploited after correctly aligning the sensor axes with the underlying anatomical axes. Emerging model-based inertial-sensor-to-bone alignment methods relate inertial measurements with a model of the joint to overcome calibration movements and sensor placement assumptions. It is unclear how good such alignment methods can identify the anatomical axes. Any misalignment results in kinematic cross-talk errors, which makes model validation and the interpretation of the resulting kinematics measurements challenging. This study provides an anatomically correct ground-truth reference dataset from dynamic motions on a cadaver. In contrast with existing references, this enables a true model evaluation that overcomes influences from soft-tissue artifacts, orientation and manual palpation errors. This dataset comprises extensive dynamic movements that are recorded with multimodal measurements including trajectories of optical and virtual (via computed tomography) anatomical markers, reference kinematics, inertial measurements, transformation matrices and visualization tools. The dataset can be used either as a ground-truth reference or to advance research in inertial-sensor-to-bone-alignment.
Collapse
|
10
|
Training Data Selection and Optimal Sensor Placement for Deep-Learning-Based Sparse Inertial Sensor Human Posture Reconstruction. ENTROPY 2021; 23:e23050588. [PMID: 34068635 PMCID: PMC8151896 DOI: 10.3390/e23050588] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 05/06/2021] [Accepted: 05/06/2021] [Indexed: 11/16/2022]
Abstract
Although commercial motion-capture systems have been widely used in various applications, the complex setup limits their application scenarios for ordinary consumers. To overcome the drawbacks of wearability, human posture reconstruction based on a few wearable sensors have been actively studied in recent years. In this paper, we propose a deep-learning-based sparse inertial sensor human posture reconstruction method. This method uses bidirectional recurrent neural network (Bi-RNN) to build an a priori model from a large motion dataset to build human motion, thereby the low-dimensional motion measurements are mapped to whole-body posture. To improve the motion reconstruction performance for specific application scenarios, two fundamental problems in the model construction are investigated: training data selection and sparse sensor placement. The problem of deep-learning training data selection is to select independent and identically distributed (IID) data for a certain scenario from the accumulated imbalanced motion dataset with sufficient information. We formulate the data selection into an optimization problem to obtain continuous and IID data segments, which comply with a small reference dataset collected from the target scenario. A two-step heuristic algorithm is proposed to solve the data selection problem. On the other hand, the optimal sensor placement problem is studied to exploit most information from partial observation of human movement. A method for evaluating the motion information amount of any group of wearable inertial sensors based on mutual information is proposed, and a greedy searching method is adopted to obtain the approximate optimal sensor placement of a given sensor number, so that the maximum motion information and minimum redundancy is achieved. Finally, the human posture reconstruction performance is evaluated with different training data and sensor placement selection methods, and experimental results show that the proposed method takes advantages in both posture reconstruction accuracy and model training time. In the 6 sensors configuration, the posture reconstruction errors of our model for walking, running, and playing basketball are 7.25°, 8.84°, and 14.13°, respectively.
Collapse
|
11
|
Inertial-Based Human Motion Capture: A Technical Summary of Current Processing Methodologies for Spatiotemporal and Kinematic Measures. Appl Bionics Biomech 2021; 2021:6628320. [PMID: 33859720 PMCID: PMC8024877 DOI: 10.1155/2021/6628320] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Revised: 03/04/2021] [Accepted: 03/11/2021] [Indexed: 11/18/2022] Open
Abstract
Inertial-based motion capture (IMC) has been suggested to overcome many of the limitations of traditional motion capture systems. The validity of IMC is, however, suggested to be dependent on the methodologies used to process the raw data collected by the inertial device. The aim of this technical summary is to provide researchers and developers with a starting point from which to further develop the current IMC data processing methodologies used to estimate human spatiotemporal and kinematic measures. The main workflow pertaining to the estimation of spatiotemporal and kinematic measures was presented, and a general overview of previous methodologies used for each stage of data processing was provided. For the estimation of spatiotemporal measures, which includes stride length, stride rate, and stance/swing duration, measurement thresholding and zero-velocity update approaches were discussed as the most common methodologies used to estimate such measures. The methodologies used for the estimation of joint kinematics were found to be broad, with the combination of Kalman filtering or complimentary filtering and various sensor to segment alignment techniques including anatomical alignment, static calibration, and functional calibration methods identified as being most common. The effect of soft tissue artefacts, device placement, biomechanical modelling methods, and ferromagnetic interference within the environment, on the accuracy and validity of IMC, was also discussed. Where a range of methods have previously been used to estimate human spatiotemporal and kinematic measures, further development is required to reduce estimation errors, improve the validity of spatiotemporal and kinematic estimations, and standardize data processing practices. It is anticipated that this technical summary will reduce the time researchers and developers require to establish the fundamental methodological components of IMC prior to commencing further development of IMC methodologies, thus increasing the rate of development and utilisation of IMC.
Collapse
|
12
|
Inertial-Robotic Motion Tracking in End-Effector-Based Rehabilitation Robots. Front Robot AI 2021; 7:554639. [PMID: 33501318 PMCID: PMC7806092 DOI: 10.3389/frobt.2020.554639] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Accepted: 10/12/2020] [Indexed: 11/20/2022] Open
Abstract
End-effector-based robotic systems provide easy-to-set-up motion support in rehabilitation of stroke and spinal-cord-injured patients. However, measurement information is obtained only about the motion of the limb segments to which the systems are attached and not about the adjacent limb segments. We demonstrate in one particular experimental setup that this limitation can be overcome by augmenting an end-effector-based robot with a wearable inertial sensor. Most existing inertial motion tracking approaches rely on a homogeneous magnetic field and thus fail in indoor environments and near ferromagnetic materials and electronic devices. In contrast, we propose a magnetometer-free sensor fusion method. It uses a quaternion-based algorithm to track the heading of a limb segment in real time by combining the gyroscope and accelerometer readings with position measurements of one point along that segment. We apply this method to an upper-limb rehabilitation robotics use case in which the orientation and position of the forearm and elbow are known, and the orientation and position of the upper arm and shoulder are estimated by the proposed method using an inertial sensor worn on the upper arm. Experimental data from five healthy subjects who performed 282 proper executions of a typical rehabilitation motion and 163 executions with compensation motion are evaluated. Using a camera-based system as a ground truth, we demonstrate that the shoulder position and the elbow angle are tracked with median errors around 4 cm and 4°, respectively; and that undesirable compensatory shoulder movements, which were defined as shoulder displacements greater ±10 cm for more than 20% of a motion cycle, are detected and classified 100% correctly across all 445 performed motions. The results indicate that wearable inertial sensors and end-effector-based robots can be combined to provide means for effective rehabilitation therapy with likewise detailed and accurate motion tracking for performance assessment, real-time biofeedback and feedback control of robotic and neuroprosthetic motion support.
Collapse
|
13
|
Body-Worn IMU Human Skeletal Pose Estimation Using a Factor Graph-Based Optimization Framework. SENSORS (BASEL, SWITZERLAND) 2020; 20:E6887. [PMID: 33276492 PMCID: PMC7729748 DOI: 10.3390/s20236887] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 11/17/2020] [Accepted: 11/28/2020] [Indexed: 11/17/2022]
Abstract
Traditionally, inertial measurement units- (IMU) based human joint angle estimation requires a priori knowledge about sensor alignment or specific calibration motions. Furthermore, magnetometer measurements can become unreliable indoors. Without magnetometers, however, IMUs lack a heading reference, which leads to unobservability issues. This paper proposes a magnetometer-free estimation method, which provides desirable observability qualities under joint kinematics that sufficiently excite the lower body degrees of freedom. The proposed lower body model expands on the current self-calibrating human-IMU estimation literature and demonstrates a novel knee hinge model, the inclusion of segment length anthropometry, segment cross-leg length discrepancy, and the relationship between the knee axis and femur/tibia segment. The maximum a posteriori problem is formulated as a factor graph and inference is performed via post-hoc, on-manifold global optimization. The method is evaluated (N = 12) for a prescribed human motion profile task. Accuracy of derived knee flexion/extension angle (4.34∘ root mean square error (RMSE)) without magnetometers is similar to current state-of-the-art with magnetometer use. The developed framework can be expanded for modeling additional joints and constraints.
Collapse
|
14
|
Recent Progress in Sensing and Computing Techniques for Human Activity Recognition and Motion Analysis. ELECTRONICS 2020. [DOI: 10.3390/electronics9091357] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
The recent scientific and technical advances in Internet of Things (IoT) based pervasive sensing and computing have created opportunities for the continuous monitoring of human activities for different purposes. The topic of human activity recognition (HAR) and motion analysis, due to its potentiality in human–machine interaction (HMI), medical care, sports analysis, physical rehabilitation, assisted daily living (ADL), children and elderly care, has recently gained increasing attention. The emergence of some novel sensing devices featuring miniature size, a light weight, and wireless data transmission, the availability of wireless communication infrastructure, the progress of machine learning and deep learning algorithms, and the widespread IoT applications has promised new opportunities for a significant progress in this particular field. Motivated by a great demand for HAR-related applications and the lack of a timely report of the recent contributions to knowledge in this area, this investigation aims to provide a comprehensive survey and in-depth analysis of the recent advances in the diverse techniques and methods of human activity recognition and motion analysis. The focus of this investigation falls on the fundamental theories, the innovative applications with their underlying sensing techniques, data fusion and processing, and human activity classification methods. Based on the state-of-the-art, the technical challenges are identified, and future perspectives on the future rich, sensing, intelligent IoT world are given in order to provide a reference for the research and practices in the related fields.
Collapse
|
15
|
Validity and reliability of inertial sensors for elbow and wrist range of motion assessment. PeerJ 2020; 8:e9687. [PMID: 32864213 PMCID: PMC7427560 DOI: 10.7717/peerj.9687] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Accepted: 07/18/2020] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND Elbow and wrist chronic conditions are very common among musculoskeletal problems. These painful conditions affect muscle function, which ultimately leads to a decrease in the joint's Range Of Motion (ROM). Due to their portability and ease of use, goniometers are still the most widespread tool for measuring ROM. Inertial sensors are emerging as a digital, low-cost and accurate alternative. However, whereas inertial sensors are commonly used in research studies, due to the lack of information about their validity and reliability, they are not widely used in the clinical practice. The goal of this study is to assess the validity and intra-inter-rater reliability of inertial sensors for measuring active ROM of the elbow and wrist. MATERIALS AND METHODS Measures were taken simultaneously with inertial sensors (Werium™ system) and a universal goniometer. The process involved two physiotherapists ("rater A" and "rater B") and an engineer responsible for the technical issues. Twenty-nine asymptomatic subjects were assessed individually in two sessions separated by 48 h. The procedure was repeated by rater A followed by rater B with random order. Three repetitions of each active movement (elbow flexion, pronation, and supination; and wrist flexion, extension, radial deviation and ulnar deviation) were executed starting from the neutral position until the ROM end-feel; that is, until ROM reached its maximum due to be stopped by the anatomy. The coefficient of determination (r 2) and the Intraclass Correlation Coefficient (ICC) were calculated to assess the intra-rater and inter-rater reliability. The Standard Error of the Measurement and the Minimum Detectable Change and a Bland-Altman plots were also calculated. RESULTS Similar ROM values when measured with both instruments were obtained for the elbow (maximum difference of 3° for all the movements) and wrist (maximum difference of 1° for all the movements). These values were within the normal range when compared to literature studies. The concurrent validity analysis for all the movements yielded ICC values ≥0.78 for the elbow and ≥0.95 for the wrist. Concerning reliability, the ICC values denoted a high reliability of inertial sensors for all the different movements. In the case of the elbow, intra-rater and inter-rater reliability ICC values range from 0.83 to 0.96 and from 0.94 to 0.97, respectively. Intra-rater analysis of the wrist yielded ICC values between 0.81 and 0.93, while the ICC values for the inter-rater analysis range from 0.93 to 0.99. CONCLUSIONS Inertial sensors are a valid and reliable tool for measuring elbow and wrist active ROM. Particularly noteworthy is their high inter-rater reliability, often questioned in measurement tools. The lowest reliability is observed in elbow prono-supination, probably due to skin artifacts. Based on these results and their advantages, inertial sensors can be considered a valid assessment tool for wrist and elbow ROM.
Collapse
|
16
|
An inertial measurement unit tracking system for body movement in comparison with optical tracking. Proc Inst Mech Eng H 2020; 234:728-737. [DOI: 10.1177/0954411920921695] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The recent advancement of motion tracking technology offers better treatment tools for conditions, such as movement disorders, as the outcome of the rehabilitation could be quantitatively defined. The accurate and fast angular information output of the inertial measurement unit tracking systems enables the collection of accurate kinematic data for clinical assessment. This article presents a study of a low-cost microelectromechanical system inertial measurement unit-based tracking system in comparison with the conventional optical tracking system. The system consists of seven microelectromechanical system inertial measurement units, which could be mounted on the lower limbs of the subjects. For the feasibility test, 10 human participants were instructed to perform three different motions: walking, running, and fencing lunges when wearing specially designed sleeves. The subjects’ lower body movements were tracked using our inertial measurement unit-based system and compared with the gold standard—the NDI Polaris Vega optical tracking system. The results of the angular comparison between the inertial measurement unit and the NDI Polaris Vega optical tracking system were as follows: the average cross-correlation value was 0.85, the mean difference of joint angles was 2.00°, and the standard deviation of joint angles was ± 2.65°. The developed microelectromechanical system–based tracking system provides an alternative low-cost solution to track joint movement. Moreover, it is able to operate on an Android platform and could potentially be used to assist outdoor or home-based rehabilitation.
Collapse
|
17
|
Determining anatomical frames via inertial motion capture: A survey of methods. J Biomech 2020; 106:109832. [PMID: 32517995 DOI: 10.1016/j.jbiomech.2020.109832] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Revised: 04/28/2020] [Accepted: 05/05/2020] [Indexed: 11/26/2022]
Abstract
Despite the exponential growth in using inertial measurement units (IMUs) for biomechanical studies, future growth in "inertial motion capture" is stymied by a fundamental challenge - how to estimate the orientation of underlying bony anatomy using skin-mounted IMUs. This challenge is of paramount importance given the need to deduce the orientation of the bony anatomy to estimate joint angles. This paper systematically surveys a large number (N = 112) of studies from 2000 to 2018 that employ four broad categories of methods to address this challenge across a range of body segments and joints. We categorize these methods as: (1) Assumed Alignment methods, (2) Functional Alignment methods, (3) Model Based methods, and (4) Augmented Data methods. Assumed Alignment methods, which are simple and commonly used, require the researcher to visually align the IMU sense axes with the underlying anatomical axes. Functional Alignment methods, also commonly used, relax the need for visual alignment but require the subject to complete prescribed movements. Model Based methods further relax the need for prescribed movements but instead assume a model for the joint. Finally, Augmented Data methods shed all of the above assumptions, but require data from additional sensors. Significantly different estimates of the underlying anatomical axes arise both across and within these categories, and to a degree that renders it difficult, if not impossible, to compare results across studies. Consequently, a significant future need remains for creating and adopting a standard for defining anatomical axes via inertial motion capture to fully realize this technology's potential for biomechanical studies.
Collapse
|
18
|
Magnetometer-free Realtime Inertial Motion Tracking by Exploitation of Kinematic Constraints in 2-DoF Joints. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:1233-1238. [PMID: 31946115 DOI: 10.1109/embc.2019.8857535] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Inertial Measurement Units (IMUs) are used to track the motion of kinematic chains in a wide variety of robotic and biomedical applications. However, inertial motion tracking is severely limited by the fact that magnetic fields are inhomogeneous in indoor environments and near electronic devices. Methods that use only accelerations and angular rates for orientation estimation yield no absolute heading information and suffer from heading drift. To overcome this limitation, we propose a novel method that exploits an orientation-based kinematic constraint in joints with two degrees of freedom (DoF), such as cardan joints, saddle joints, the human wrists, elbow or ankles. The method determines the relative heading of the joint segments in real time by minimization of a nonlinear cost function. A filter for singularity treatment ensures accurate tracking during motion phases for which the cost function minimum is ambiguous. We experimentally validate the method in metacarpophalangeal (MCP) joints between the palm and the fingers. Accurate relative orientation tracking is achieved continuously despite several singular motion phases and even though the heading components of the 6D orientations drift by more than 360 degrees within ten minutes. The proposed method overcomes a major limitation of inertial motion tracking and thereby facilitates the use of this technology in robotic and biomechanical applications.
Collapse
|
19
|
Estimation of Gait Mechanics Based on Simulated and Measured IMU Data Using an Artificial Neural Network. Front Bioeng Biotechnol 2020; 8:41. [PMID: 32117923 PMCID: PMC7013109 DOI: 10.3389/fbioe.2020.00041] [Citation(s) in RCA: 56] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Accepted: 01/20/2020] [Indexed: 11/13/2022] Open
Abstract
Enhancement of activity is one major topic related to the aging society. Therefore, it is necessary to understand people's motion and identify possible risk factors during activity. Technology can be used to monitor motion patterns during daily life. Especially the use of artificial intelligence combined with wearable sensors can simplify measurement systems and might at some point replace the standard motion capturing using optical measurement technologies. Therefore, this study aims to analyze the estimation of 3D joint angles and joint moments of the lower limbs based on IMU data using a feedforward neural network. The dataset summarizes optical motion capture data of former studies and additional newly collected IMU data. Based on the optical data, the acceleration and angular rate of inertial sensors was simulated. The data was augmented by simulating different sensor positions and orientations. In this study, gait analysis was undertaken with 30 participants using a conventional motion capture set-up based on an optoelectronic system and force plates in parallel with a custom IMU system consisting of five sensors. A mean correlation coefficient of 0.85 for the joint angles and 0.95 for the joint moments was achieved. The RMSE for the joint angle prediction was smaller than 4.8° and the nRMSE for the joint moment prediction was below 13.0%. Especially in the sagittal motion plane good results could be achieved. As the measured dataset is rather small, data was synthesized to complement the measured data. The enlargement of the dataset improved the prediction of the joint angles. While size did not affect the joint moment prediction, the addition of noise to the dataset resulted in an improved prediction accuracy. This indicates that research on appropriate augmentation techniques for biomechanical data is useful to further improve machine learning applications.
Collapse
|
20
|
IMU-based Assessment of Ankle Inversion Kinematics and Orthosis Migration. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:6395-6400. [PMID: 31947306 DOI: 10.1109/embc.2019.8856661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Ankle orthoses are used to prevent injuries during very fast inversion motions of the ankle. In order to provide proper protection, they must fit well and migrate as little as possible. Inertial measurement units (IMUs) have become a useful tool for accurate motion analysis and are frequently used for gait analysis. In the present paper, we examine orthosis migration and inversion kinematics of human ankles protected and unprotected by an orthosis. We present two test benches that were developed for these purposes, as well as a set of inertial sensor fusion methods that are used to determine kinematic parameters from the sensor readings. To avoid the common but restrictive assumption of a homogeneous magnetic field, we determine all motion parameters without the use of magnetometer readings. We conduct a measurement series to compare the proposed IMU-based method to alternative camera-based and goniometer-based methods. Using two different ankle orthosis prototypes, we demonstrate that the proposed IMU-based methods facilitate accurate assessment of orthosis migration and ankle inversion kinematics.
Collapse
|
21
|
A Survey of Healthcare Internet-of-Things (HIoT): A Clinical Perspective. IEEE INTERNET OF THINGS JOURNAL 2020; 7:53-71. [PMID: 33748312 PMCID: PMC7970885 DOI: 10.1109/jiot.2019.2946359] [Citation(s) in RCA: 59] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
In combination with current sociological trends, the maturing development of IoT devices is projected to revolutionize healthcare. A network of body-worn sensors, each with a unique ID, can collect health data that is orders-of-magnitude richer than what is available today from sporadic observations in clinical/hospital environments. When databased, analyzed, and compared against information from other individuals using data analytics, HIoT data enables the personalization and modernization of care with radical improvements in outcomes and reductions in cost. In this paper, we survey existing and emerging technologies that can enable this vision for the future of healthcare, particularly in the clinical practice of healthcare. Three main technology areas underlie the development of this field: (a) sensing, where there is an increased drive for miniaturization and power efficiency; (b) communications, where the enabling factors are ubiquitous connectivity, standardized protocols, and the wide availability of cloud infrastructure, and (c) data analytics and inference, where the availability of large amounts of data and computational resources is revolutionizing algorithms for individualizing inference and actions in health management. Throughout the paper, we use a case study to concretely illustrate the impact of these trends. We conclude our paper with a discussion of the emerging directions, open issues, and challenges.
Collapse
|
22
|
Magnetic Condition-Independent 3D Joint Angle Estimation Using Inertial Sensors and Kinematic Constraints. SENSORS 2019; 19:s19245522. [PMID: 31847254 PMCID: PMC6960945 DOI: 10.3390/s19245522] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/28/2019] [Revised: 12/02/2019] [Accepted: 12/12/2019] [Indexed: 11/18/2022]
Abstract
In biomechanics, joint angle estimation using wearable inertial measurement units (IMUs) has been getting great popularity. However, magnetic disturbance issue is considered problematic as the disturbance can seriously degrade the accuracy of the estimated joint angles. This study proposes a magnetic condition-independent three-dimensional (3D) joint angle estimation method based on IMU signals. The proposed method is implemented in a sequential direction cosine matrix-based orientation Kalman filter (KF), which is composed of an attitude estimation KF followed by a heading estimation KF. In the heading estimation KF, an acceleration-level kinematic constraint from a spherical joint replaces the magnetometer signals for the correction procedure. Because the proposed method does not rely on the magnetometer, it is completely magnetic condition-independent and is not affected by the magnetic disturbance. For the averaged root mean squared errors of the three tests performed using a rigid two-link system, the proposed method produced 1.58°, while the conventional method with the magnetic disturbance compensation mechanism produced 5.38°, showing a higher accuracy of the proposed method in the magnetically disturbed conditions. Due to the independence of the proposed method from the magnetic condition, the proposed approach could be reliably applied in various fields that require robust 3D joint angle estimation through IMU signals in an unspecified arbitrary magnetic environment.
Collapse
|
23
|
Validation of Novel Relative Orientation and Inertial Sensor-to-Segment Alignment Algorithms for Estimating 3D Hip Joint Angles. SENSORS 2019; 19:s19235143. [PMID: 31771263 PMCID: PMC6929122 DOI: 10.3390/s19235143] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/16/2019] [Revised: 11/16/2019] [Accepted: 11/22/2019] [Indexed: 11/16/2022]
Abstract
Wearable sensor-based algorithms for estimating joint angles have seen great improvements in recent years. While the knee joint has garnered most of the attention in this area, algorithms for estimating hip joint angles are less available. Herein, we propose and validate a novel algorithm for this purpose with innovations in sensor-to-sensor orientation and sensor-to-segment alignment. The proposed approach is robust to sensor placement and does not require specific calibration motions. The accuracy of the proposed approach is established relative to optical motion capture and compared to existing methods for estimating relative orientation, hip joint angles, and range of motion (ROM) during a task designed to exercise the full hip range of motion (ROM) and fast walking using root mean square error (RMSE) and regression analysis. The RMSE of the proposed approach was less than that for existing methods when estimating sensor orientation ( 12 . 32 ∘ and 11 . 82 ∘ vs. 24 . 61 ∘ and 23 . 76 ∘ ) and flexion/extension joint angles ( 7 . 88 ∘ and 8 . 62 ∘ vs. 14 . 14 ∘ and 15 . 64 ∘ ). Also, ROM estimation error was less than 2 . 2 ∘ during the walking trial using the proposed method. These results suggest the proposed approach presents an improvement to existing methods and provides a promising technique for remote monitoring of hip joint angles.
Collapse
|
24
|
IMU-based sensor-to-segment multiple calibration for upper limb joint angle measurement-a proof of concept. Med Biol Eng Comput 2019; 57:2449-2460. [PMID: 31471784 DOI: 10.1007/s11517-019-02033-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2018] [Accepted: 08/14/2019] [Indexed: 10/26/2022]
Abstract
A lot of attention has been paid to wearable inertial sensors regarded as an alternative solution for outdoor human motion tracking. Relevant joint angles can only be calculated from anatomical orientations, but they are negatively impacted by soft tissue artifact (STA) defined as skin motion with respect to the underlying bone; the accuracy of measured joint angle during movement is affected by the ongoing misalignment of the sensor. In this work, a new sensor-to-segment calibration using inertial measurement units is proposed. Inspired by the multiple calibration for a cluster of skin markers, it consists in performing first multiple static postures of the upper limb in all anatomical planes. The movements that affect sensor alignment are identified then alignment differences between sensors and segment frames are calculated for each posture and linearly interpolated. Experimental measurements were carried out on a mechanical model and on a subject who performed different movements of right elbow and shoulder. Multiple calibration showed significant improvement in joint angle measurement on the mechanical model as well as on human joint angle comparing to those obtained from attached sensors after technical calibration. During shoulder internal-external rotation, the maximal error value decreased more than 50% after correction. Graphical abstract Elbow flexion-extension joint angle values obtained from IMUs are well-corrected after applying multiple calibration procedure. Though shoulder internal-external rotation joint angle is more affected by soft tissue artifact, multiple calibration procedure improves the angle values obtained from IMUs.
Collapse
|
25
|
Abstract
Simultaneous tracking of muscle activity and joint rotation is of significant interest in rehabilitation, but gold-standard methods with optical motion tracking and wireless electromyography recording typically restricts this to the laboratory setting. There has been significant progress using wear-able inertial measurement units (IMUs) for motion tracking, but there are no systems that can easily be deployed to home and provide simultaneous electromyography. We addressed this gap by developing a flexible, wearable, Bluetooth-connected sensor that records both IMU and EMG activity. The sensor runs an efficient quaternion-based complementary filter that estimates the sensor orientation while correcting for estimate drift and constraining magnetometer estimates to only influence heading. The difference in two sensor orientations is used to estimate the joint angle, which can be further improved with joint axis estimation. We demonstrate successful tracking of joint angle and muscle activity in a home environment with just the sensors and a smartphone.
Collapse
|
26
|
A Tangible Solution for Hand Motion Tracking in Clinical Applications. SENSORS 2019; 19:s19010208. [PMID: 30626130 PMCID: PMC6339214 DOI: 10.3390/s19010208] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/21/2018] [Revised: 12/22/2018] [Accepted: 12/23/2018] [Indexed: 11/16/2022]
Abstract
Objective real-time assessment of hand motion is crucial in many clinical applications including technically-assisted physical rehabilitation of the upper extremity. We propose an inertial-sensor-based hand motion tracking system and a set of dual-quaternion-based methods for estimation of finger segment orientations and fingertip positions. The proposed system addresses the specific requirements of clinical applications in two ways: (1) In contrast to glove-based approaches, the proposed solution maintains the sense of touch. (2) In contrast to previous work, the proposed methods avoid the use of complex calibration procedures, which means that they are suitable for patients with severe motor impairment of the hand. To overcome the limited significance of validation in lab environments with homogeneous magnetic fields, we validate the proposed system using functional hand motions in the presence of severe magnetic disturbances as they appear in realistic clinical settings. We show that standard sensor fusion methods that rely on magnetometer readings may perform well in perfect laboratory environments but can lead to more than 15 cm root-mean-square error for the fingertip distances in realistic environments, while our advanced method yields root-mean-square errors below 2 cm for all performed motions.
Collapse
|
27
|
Reliability and Agreement of 3D Trunk and Lower Extremity Movement Analysis by Means of Inertial Sensor Technology for Unipodal and Bipodal Tasks. SENSORS 2019; 19:s19010141. [PMID: 30609808 PMCID: PMC6339112 DOI: 10.3390/s19010141] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/06/2018] [Revised: 12/21/2018] [Accepted: 12/23/2018] [Indexed: 11/16/2022]
Abstract
This study evaluates the reliability and agreement of the 3D range of motion (ROM) of trunk and lower limb joints, measured by inertial measurement units (MVN BIOMECH Awinda, Xsens Technologies), during a single leg squat (SLS) and sit to stand (STS) task. Furthermore, distinction was made between movement phases, to discuss the reliability and agreement for different phases of both movement tasks. Twenty healthy participants were measured on two testing days. On day one, measurements were conducted by two operators to determine the within-session and between-operator reliability and agreement. On day two, measurements were conducted by the same operator, to determine the between-session reliability and agreement. The SLS task had lower within-session reliability and agreement compared with between-session and between-operator reliability and agreement. The reliability and agreement of the hip, knee, and ankle ROM in the sagittal plane were good for both phases of the SLS task. For both phases of STS task, within-session reliability and agreement were good, and between-session and between-operator reliability and agreement were lower in all planes. As both tasks are physically demanding, differences may be explained by inconsistent movement strategies. These results show that inertial sensor systems show promise for use in further research to investigate (mal)adaptive movement strategies.
Collapse
|
28
|
Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review. SPORTS MEDICINE-OPEN 2018; 4:53. [PMID: 30499058 PMCID: PMC6265374 DOI: 10.1186/s40798-018-0167-7] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Accepted: 10/24/2018] [Indexed: 12/18/2022]
Abstract
Background Wearable sensors are portable measurement tools that are becoming increasingly popular for the measurement of joint angle in the upper limb. With many brands emerging on the market, each with variations in hardware and protocols, evidence to inform selection and application is needed. Therefore, the objectives of this review were related to the use of wearable sensors to calculate upper limb joint angle. We aimed to describe (i) the characteristics of commercial and custom wearable sensors, (ii) the populations for whom researchers have adopted wearable sensors, and (iii) their established psychometric properties. Methods A systematic review of literature was undertaken using the following data bases: MEDLINE, EMBASE, CINAHL, Web of Science, SPORTDiscus, IEEE, and Scopus. Studies were eligible if they met the following criteria: (i) involved humans and/or robotic devices, (ii) involved the application or simulation of wearable sensors on the upper limb, and (iii) calculated a joint angle. Results Of 2191 records identified, 66 met the inclusion criteria. Eight studies compared wearable sensors to a robotic device and 22 studies compared to a motion analysis system. Commercial (n = 13) and custom (n = 7) wearable sensors were identified, each with variations in placement, calibration methods, and fusion algorithms, which were demonstrated to influence accuracy. Conclusion Wearable sensors have potential as viable instruments for measurement of joint angle in the upper limb during active movement. Currently, customised application (i.e. calibration and angle calculation methods) is required to achieve sufficient accuracy (error < 5°). Additional research and standardisation is required to guide clinical application. Trial Registration This systematic review was registered with PROSPERO (CRD42017059935).
Collapse
|
29
|
Joint Center Estimation Using Single-Frame Optimization: Part 2: Experimentation. SENSORS 2018; 18:s18082563. [PMID: 30081601 PMCID: PMC6112042 DOI: 10.3390/s18082563] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Revised: 07/13/2018] [Accepted: 08/03/2018] [Indexed: 11/16/2022]
Abstract
Human motion capture is driven by joint center location estimates, and error in their estimation can be compounded by subsequent kinematic calculations. Soft tissue artifact (STA), the motion of tissue relative to the underlying bones, is a primary cause of error in joint center calculations. A method for mitigating the effects of STA, single-frame optimization (SFO), was introduced and numerically verified in Part 1 of this work, and the purpose of this article (Part 2) is to experimentally compare the results of SFO with a marker-based solution. The experimentation herein employed a single-degree-of-freedom pendulum to simulate human joint motion, and the effects of STA were simulated by affixing the inertial measurement unit to the pendulum indirectly through raw, vacuum-sealed meat. The inertial sensor was outfitted with an optical marker adapter so that its location could be optically determined by a camera-based motion-capture system. During the motion, inertial effects and non-rigid attachment of the inertial sensor caused the simulated STA to manifest via unrestricted motion (six degrees of freedom) relative to the rigid pendulum. The redundant inertial and optical instrumentation allowed a time-varying joint center solution to be determined both by optical markers and by SFO, allowing for comparison. The experimental results suggest that SFO can achieve accuracy comparable to that of state-of-the-art joint center determination methods that use optical skin markers (root mean square error of 7.87–37.86 mm), and that the time variances of the SFO solutions are correlated (r = 0.58–0.99) with the true, time-varying joint center solutions. This suggests that SFO could potentially help to fill a gap in the existing literature by improving the characterization and mitigation of STA in human motion capture.
Collapse
|
30
|
An Auto-Calibrating Knee Flexion-Extension Axis Estimator Using Principal Component Analysis with Inertial Sensors. SENSORS 2018; 18:s18061882. [PMID: 29890667 PMCID: PMC6021833 DOI: 10.3390/s18061882] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/27/2018] [Revised: 06/03/2018] [Accepted: 06/06/2018] [Indexed: 01/08/2023]
Abstract
Inertial measurement units (IMUs) have been demonstrated to reliably measure human joint angles—an essential quantity in the study of biomechanics. However, most previous literature proposed IMU-based joint angle measurement systems that required manual alignment or prescribed calibration motions. This paper presents a simple, physically-intuitive method for IMU-based measurement of the knee flexion/extension angle in gait without requiring alignment or discrete calibration, based on computationally-efficient and easy-to-implement Principle Component Analysis (PCA). The method is compared against an optical motion capture knee flexion/extension angle modeled through OpenSim. The method is evaluated using both measured and simulated IMU data in an observational study (n = 15) with an absolute root-mean-square-error (RMSE) of 9.24∘ and a zero-mean RMSE of 3.49∘. Variation in error across subjects was found, made emergent by the larger subject population than previous literature considers. Finally, the paper presents an explanatory model of RMSE on IMU mounting location. The observational data suggest that RMSE of the method is a function of thigh IMU perturbation and axis estimation quality. However, the effect size for these parameters is small in comparison to potential gains from improved IMU orientation estimations. Results also highlight the need to set relevant datums from which to interpret joint angles for both truth references and estimated data.
Collapse
|
31
|
Joint Center Estimation Using Single-Frame Optimization: Part 1: Numerical Simulation. SENSORS 2018; 18:s18041089. [PMID: 29617331 PMCID: PMC5948776 DOI: 10.3390/s18041089] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/18/2018] [Revised: 03/30/2018] [Accepted: 04/03/2018] [Indexed: 11/29/2022]
Abstract
The biomechanical models used to refine and stabilize motion capture processes are almost invariably driven by joint center estimates, and any errors in joint center calculation carry over and can be compounded when calculating joint kinematics. Unfortunately, accurate determination of joint centers is a complex task, primarily due to measurements being contaminated by soft-tissue artifact (STA). This paper proposes a novel approach to joint center estimation implemented via sequential application of single-frame optimization (SFO). First, the method minimizes the variance of individual time frames’ joint center estimations via the developed variance minimization method to obtain accurate overall initial conditions. These initial conditions are used to stabilize an optimization-based linearization of human motion that determines a time-varying joint center estimation. In this manner, the complex and nonlinear behavior of human motion contaminated by STA can be captured as a continuous series of unique rigid-body realizations without requiring a complex analytical model to describe the behavior of STA. This article intends to offer proof of concept, and the presented method must be further developed before it can be reasonably applied to human motion. Numerical simulations were introduced to verify and substantiate the efficacy of the proposed methodology. When directly compared with a state-of-the-art inertial method, SFO reduced the error due to soft-tissue artifact in all cases by more than 45%. Instead of producing a single vector value to describe the joint center location during a motion capture trial as existing methods often do, the proposed method produced time-varying solutions that were highly correlated (r > 0.82) with the true, time-varying joint center solution.
Collapse
|
32
|
Wearable Heading Estimation for Motion Tracking in Health Care by Adaptive Fusion of Visual-Inertial Measurements. IEEE J Biomed Health Inform 2018; 22:1732-1743. [PMID: 29994357 DOI: 10.1109/jbhi.2018.2795006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/28/2024]
Abstract
The increasing demand for health informatics has become a far-reaching trend in the ageing society. The utilization of wearable sensors enables monitoring senior people daily activities in free-living environments, conveniently and effectively. Among the primary health-care sensing categories, the wearable visual-inertial modality for human motion tracking gradually exerts promising potentials. In this paper, we present a novel wearable heading estimation strategy to track the movements of human limbs. It adaptively fuses inertial measurements with visual features following locality constraints. Body movements are classified into two types: general motion (which consists of both rotation and translation). or degenerate motion (which consists of only rotation). A specific number of feature correspondences between camera frames are adaptively chosen to satisfy both the feature descriptor similarity constraint and the locality constraint. The selected feature correspondences and inertial quaternions are employed to calculate the initial pose, followed by the coarse-to-fine procedure to iteratively remove visual outliers. Eventually, the ultimate heading is optimized using the correct feature matches. The proposed method has been thoroughly evaluated on the straight-line, rotatory and ambulatory movement scenarios. As the system is lightweight and requires small computational resources, it enables effective and unobtrusive human motion monitoring, especially for the senior citizens in the long-term rehabilitation.
Collapse
|
33
|
Configurable, wearable sensing and vibrotactile feedback system for real-time postural balance and gait training: proof-of-concept. J Neuroeng Rehabil 2017; 14:102. [PMID: 29020959 PMCID: PMC5637356 DOI: 10.1186/s12984-017-0313-3] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2016] [Accepted: 10/03/2017] [Indexed: 12/26/2022] Open
Abstract
BACKGROUND Postural balance and gait training is important for treating persons with functional impairments, however current systems are generally not portable and are unable to train different types of movements. METHODS This paper describes a proof-of-concept design of a configurable, wearable sensing and feedback system for real-time postural balance and gait training targeted for home-based treatments and other portable usage. Sensing and vibrotactile feedback are performed via eight distributed, wireless nodes or "Dots" (size: 22.5 × 20.5 × 15.0 mm, weight: 12.0 g) that can each be configured for sensing and/or feedback according to movement training requirements. In the first experiment, four healthy older adults were trained to reduce medial-lateral (M/L) trunk tilt while performing balance exercises. When trunk tilt deviated too far from vertical (estimated via a sensing Dot on the lower spine), vibrotactile feedback (via feedback Dots placed on the left and right sides of the lower torso) cued participants to move away from the vibration and back toward the vertical no feedback zone to correct their posture. A second experiment was conducted with the same wearable system to train six healthy older adults to alter their foot progression angle in real-time by internally or externally rotating their feet while walking. Foot progression angle was estimated via a sensing Dot adhered to the dorsal side of the foot, and vibrotactile feedback was provided via feedback Dots placed on the medial and lateral sides of the mid-shank cued participants to internally or externally rotate their foot away from vibration. RESULTS In the first experiment, the wearable system enabled participants to significantly reduce trunk tilt and increase the amount of time inside the no feedback zone. In the second experiment, all participants were able to adopt new gait patterns of internal and external foot rotation within two minutes of real-time training with the wearable system. CONCLUSION These results suggest that the configurable, wearable sensing and feedback system is portable and effective for different types of real-time human movement training and thus may be suitable for home-based or clinic-based rehabilitation applications.
Collapse
|
34
|
Method for Estimating Three-Dimensional Knee Rotations Using Two Inertial Measurement Units: Validation with a Coordinate Measurement Machine. SENSORS 2017; 17:s17091970. [PMID: 28846613 PMCID: PMC5620966 DOI: 10.3390/s17091970] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/16/2017] [Revised: 08/24/2017] [Accepted: 08/25/2017] [Indexed: 11/16/2022]
Abstract
Three-dimensional rotations across the human knee serve as important markers of knee health and performance in multiple contexts including human mobility, worker safety and health, athletic performance, and warfighter performance. While knee rotations can be estimated using optical motion capture, that method is largely limited to the laboratory and small capture volumes. These limitations may be overcome by deploying wearable inertial measurement units (IMUs). The objective of this study is to present a new IMU-based method for estimating 3D knee rotations and to benchmark the accuracy of the results using an instrumented mechanical linkage. The method employs data from shank- and thigh-mounted IMUs and a vector constraint for the medial-lateral axis of the knee during periods when the knee joint functions predominantly as a hinge. The method is carefully validated using data from high precision optical encoders in a mechanism that replicates 3D knee rotations spanning (1) pure flexion/extension, (2) pure internal/external rotation, (3) pure abduction/adduction, and (4) combinations of all three rotations. Regardless of the movement type, the IMU-derived estimates of 3D knee rotations replicate the truth data with high confidence (RMS error < 4 ° and correlation coefficient r ≥ 0.94 ).
Collapse
|
35
|
Octopus: A Design Methodology for Motion Capture Wearables. SENSORS 2017; 17:s17081875. [PMID: 28809786 PMCID: PMC5580045 DOI: 10.3390/s17081875] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/03/2017] [Revised: 08/09/2017] [Accepted: 08/09/2017] [Indexed: 02/04/2023]
Abstract
Human motion capture (MoCap) is widely recognised for its usefulness and application in different fields, such as health, sports, and leisure; therefore, its inclusion in current wearables (MoCap-wearables) is increasing, and it may be very useful in a context of intelligent objects interconnected with each other and to the cloud in the Internet of Things (IoT). However, capturing human movement adequately requires addressing difficult-to-satisfy requirements, which means that the applications that are possible with this technology are held back by a series of accessibility barriers, some technological and some regarding usability. To overcome these barriers and generate products with greater wearability that are more efficient and accessible, factors are compiled through a review of publications and market research. The result of this analysis is a design methodology called Octopus, which ranks these factors and schematises them. Octopus provides a tool that can help define design requirements for multidisciplinary teams, generating a common framework and offering a new method of communication between them.
Collapse
|
36
|
Abstract
Abstract
The ability to capture human motion based on wearable sensors has a wide range of applications, e.g., in healthcare, sports, well-being, and workflow analysis. This article focuses on the development of an online-capable system for accurately capturing joint kinematics based on inertial measurement units (IMUs) and its clinical application, with a focus on locomotion analysis for rehabilitation. The article approaches the topic from the technology and application perspectives and fuses both points of view. It presents, in a self-contained way, previous results from three studies as well as new results concerning the technological development of the system. It also correlates these with new results from qualitative expert interviews with medical practitioners and movement scientists. The interviews were conducted for the purpose of identifying relevant application scenarios and requirements for the technology used. As a result, the potentials of the system for the different identified application scenarios are discussed and necessary next steps are deduced from this analysis.
Collapse
|