1
|
Karumuri SR, Mohammed H, Guha K, Puli AK, Einsanwi A, Kondavitee GS. Design, simulation and analysis of micro electro-mechanical system microneedle for micropump in drug delivery systems. IET Nanobiotechnol 2021; 15:484-491. [PMID: 34694756 PMCID: PMC8675835 DOI: 10.1049/nbt2.12013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 09/04/2020] [Accepted: 11/09/2020] [Indexed: 11/19/2022] Open
Abstract
This article reports on the mechanical strength analysis and flow characteristics of square tip and circular tip microneedles by employing highly potent drugs that are given in extremely little quantity (microlitres) using MEMS technology, which proves to be a significant component of micropump in the application of Bio-MEMS. These microneedles are well suitable for a MEMS-based micropump in the drug delivery systems. It is an essential part of the micropump through which the drug is released into the patient's body. The proposed microneedles can withstand a stress of 23 MPa and 20 KPa. An extensive investigation on selection of material for the microneedle is carried out to meet the requirements of the biocompatibility and high yield, as well as tensile strength. As mighty drugs such as vasopressin, atropine and digoxin are administered in large quantities, the microneedle is designed so as to deliver 800 µl of drug, with each microneedle delivering 90 µl. in a 3 3 array. 3 × 3 array releasing 90 µl.
Collapse
Affiliation(s)
- Srinivasa R Karumuri
- MEMS Research Center, Department of Electronics Communication Engineering, Koneru Lakshmaiah Education Foundation (Deemed to be University), Guntur, Andhra Pradesh, India
| | - Hamza Mohammed
- MEMS Research Center, Department of Electronics Communication Engineering, Koneru Lakshmaiah Education Foundation (Deemed to be University), Guntur, Andhra Pradesh, India
| | - Koushik Guha
- National MEMS Design Center, Department of Electronics Communication Engineering, National Institute of Technology, Silchar, Assam, India
| | - Ashok K Puli
- MEMS Research Center, Department of Electronics Communication Engineering, Koneru Lakshmaiah Education Foundation (Deemed to be University), Guntur, Andhra Pradesh, India
| | - Ameen Einsanwi
- Mechanical Engineering, American University of Iraq, Sulaimani, Iraq
| | - Girija S Kondavitee
- MEMS Research Center, Department of Electronics Communication Engineering, Koneru Lakshmaiah Education Foundation (Deemed to be University), Guntur, Andhra Pradesh, India.,National MEMS Design Center, Department of Electronics Communication Engineering, National Institute of Technology, Silchar, Assam, India
| |
Collapse
|
2
|
Fu Y, Ding Y, Zhang L, Zhang Y, Liu J, Yu P. Poly ethylene glycol (PEG)-Related controllable and sustainable antidiabetic drug delivery systems. Eur J Med Chem 2021; 217:113372. [PMID: 33744689 DOI: 10.1016/j.ejmech.2021.113372] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Revised: 02/25/2021] [Accepted: 03/04/2021] [Indexed: 12/25/2022]
Abstract
Diabetes mellitus is one of the most challenging threats to global public health. To improve the therapy efficacy of antidiabetic drugs, numerous drug delivery systems have been developed. Polyethylene glycol (PEG) is a polymeric family sharing the same skeleton but with different molecular weights which is considered as a promising material for drug delivery. In the delivery of antidiabetic drugs, PEG captures much attention in the designing and preparation of sustainable and controllable release systems due to its unique features including hydrophilicity, biocompatibility and biodegradability. Due to the unique architecture, PEG molecules are also able to shelter delivery systems to decrease their immunogenicity and avoid undesirable enzymolysis. PEG has been applied in plenty of delivery systems such as micelles, vesicles, nanoparticles and hydrogels. In this review, we summarized several commonly used PEG-contained antidiabetic drug delivery systems and emphasized the advantages of stimuli-responsive function in these sustainable and controllable formations.
Collapse
Affiliation(s)
- Yupeng Fu
- China International Science and Technology Cooperation Base of Food Nutrition/Safety and Medicinal Chemistry, Key Laboratory of Industrial Fermentation Microbiology of Ministry of Education, Tianjin Key Laboratory of Industry Microbiology, College of Biotechnology, Tianjin University of Science & Technology, 300457, Tianjin, China
| | - Ying Ding
- China International Science and Technology Cooperation Base of Food Nutrition/Safety and Medicinal Chemistry, Key Laboratory of Industrial Fermentation Microbiology of Ministry of Education, Tianjin Key Laboratory of Industry Microbiology, College of Biotechnology, Tianjin University of Science & Technology, 300457, Tianjin, China
| | - Litao Zhang
- China International Science and Technology Cooperation Base of Food Nutrition/Safety and Medicinal Chemistry, Key Laboratory of Industrial Fermentation Microbiology of Ministry of Education, Tianjin Key Laboratory of Industry Microbiology, College of Biotechnology, Tianjin University of Science & Technology, 300457, Tianjin, China
| | - Yongmin Zhang
- China International Science and Technology Cooperation Base of Food Nutrition/Safety and Medicinal Chemistry, Key Laboratory of Industrial Fermentation Microbiology of Ministry of Education, Tianjin Key Laboratory of Industry Microbiology, College of Biotechnology, Tianjin University of Science & Technology, 300457, Tianjin, China; Sorbonne Université, CNRS, IPCM, UMR 8232, 4 Place Jussieu, 75005, Paris, France
| | - Jiang Liu
- China International Science and Technology Cooperation Base of Food Nutrition/Safety and Medicinal Chemistry, Key Laboratory of Industrial Fermentation Microbiology of Ministry of Education, Tianjin Key Laboratory of Industry Microbiology, College of Biotechnology, Tianjin University of Science & Technology, 300457, Tianjin, China.
| | - Peng Yu
- China International Science and Technology Cooperation Base of Food Nutrition/Safety and Medicinal Chemistry, Key Laboratory of Industrial Fermentation Microbiology of Ministry of Education, Tianjin Key Laboratory of Industry Microbiology, College of Biotechnology, Tianjin University of Science & Technology, 300457, Tianjin, China.
| |
Collapse
|
3
|
Davoodi P, Lee LY, Xu Q, Sunil V, Sun Y, Soh S, Wang CH. Drug delivery systems for programmed and on-demand release. Adv Drug Deliv Rev 2018; 132:104-138. [PMID: 30415656 DOI: 10.1016/j.addr.2018.07.002] [Citation(s) in RCA: 200] [Impact Index Per Article: 28.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Revised: 05/25/2018] [Accepted: 07/02/2018] [Indexed: 01/06/2023]
Abstract
With the advancement in medical science and understanding the importance of biodistribution and pharmacokinetics of therapeutic agents, modern drug delivery research strives to utilize novel materials and fabrication technologies for the preparation of robust drug delivery systems to combat acute and chronic diseases. Compared to traditional drug carriers, which could only control the release of the agents in a monotonic manner, the new drug carriers are able to provide a precise control over the release time and the quantity of drug introduced into the patient's body. To achieve this goal, scientists have introduced "programmed" and "on-demand" approaches. The former provides delivery systems with a sophisticated architecture to precisely tune the release rate for a definite time period, while the latter includes systems directly controlled by an operator/practitioner, perhaps with a remote device triggering/affecting the implanted or injected drug carrier. Ideally, such devices can determine flexible release pattern and intensify the efficacy of a therapy via controlling time, duration, dosage, and location of drug release in a predictable, repeatable, and reliable manner. This review sheds light on the past and current techniques available for fabricating and remotely controlling drug delivery systems and addresses the application of new technologies (e.g. 3D printing) in this field.
Collapse
|
4
|
Cobo A, Sheybani R, Meng E. MEMS: Enabled Drug Delivery Systems. Adv Healthc Mater 2015; 4:969-82. [PMID: 25703045 DOI: 10.1002/adhm.201400772] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2014] [Revised: 02/01/2015] [Indexed: 12/25/2022]
Abstract
Drug delivery systems play a crucial role in the treatment and management of medical conditions. Microelectromechanical systems (MEMS) technologies have allowed the development of advanced miniaturized devices for medical and biological applications. This Review presents the use of MEMS technologies to produce drug delivery devices detailing the delivery mechanisms, device formats employed, and various biomedical applications. The integration of dosing control systems, examples of commercially available microtechnology-enabled drug delivery devices, remaining challenges, and future outlook are also discussed.
Collapse
Affiliation(s)
- Angelica Cobo
- Department of Biomedical Engineering; Viterbi School of Engineering; University of Southern California; 1042 Downey Way DRB-140 Los Angeles CA 90089-1111 USA
| | - Roya Sheybani
- Department of Biomedical Engineering; Viterbi School of Engineering; University of Southern California; 1042 Downey Way DRB-140 Los Angeles CA 90089-1111 USA
| | - Ellis Meng
- Department of Biomedical Engineering; Viterbi School of Engineering; University of Southern California; 1042 Downey Way DRB-140 Los Angeles CA 90089-1111 USA
- Department of Electrical Engineering; Viterbi School of Engineering; University of Southern California; 3651 Watt Way VHE-602 Los Angeles CA 90089-0241 USA
| |
Collapse
|
5
|
Optimization of flow assisted entrapment of pollen grains in a microfluidic platform for tip growth analysis. Biomed Microdevices 2014; 16:23-33. [PMID: 24013680 DOI: 10.1007/s10544-013-9802-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
A biocompatible polydimethylsiloxane (PDMS) biomicrofluidic platform is designed, fabricated and tested to study protuberance growth of single plant cells in a micro-vitro environment. The design consists of an inlet to introduce the cell suspension into the chip, three outlets to conduct the medium or cells out of the chip, a main distribution chamber and eight microchannels connected to the main chamber to guide the growth of tip growing plant cells. The test cells used here were pollen grains which produce cylindrical protrusions called pollen tubes. The goal was to adjust the design of the microfluidic network with the aim to enhance the uniformly distributed positioning of pollen grains at the entrances of the microchannels and to provide identical fluid flow conditions for growing pollen tubes along each microchannel. Computational fluid analysis and experimental testing were carried out to estimate the trapping efficiencies of the different designs.
Collapse
|
6
|
Abstract
Conventional methods of plant cell analysis rely on growing plant cells in soil pots or agarose plates, followed by screening the plant phenotypes in traditional greenhouses and growth chambers. These methods are usually costly, need a large number of experiments, suffer from low spatial resolution and disorderly growth behavior of plant cells, with lack of ability to locally and accurately manipulate the plant cells. Microfluidic platforms take advantage of miniaturization for handling small volume of liquids and providing a closed environment, with the purpose of in vitro single cell analysis and characterizing cell response to external cues. These platforms have shown their ability for high-throughput cellular analysis with increased accuracy of experiments, reduced cost and experimental times, versatility in design, ability for large-scale and combinatorial screening, and integration with other miniaturized sensors. Despite extensive research on animal cells within microfluidic environments for high-throughput sorting, manipulation and phenotyping studies, the application of microfluidics for plant cells studies has not been accomplished yet. Novel devices such as RootChip, RootArray, TipChip, and PlantChip developed for plant cells analysis, with high spatial resolution on a micrometer scale mimicking the internal microenvironment of plant cells, offering preliminary results on the capability of microfluidics to conquer the constraints of conventional methods. These devices have been used to study different aspects of plant cell biology such as gene expression, cell biomechanics, cellular mechanism of growth, cell division, and cells fusion. This review emphasizes the advantages of current microfluidic systems for plant science studies, and discusses future prospects of microfluidic platforms for characterizing plant cells response to diverse external cues.
Collapse
Affiliation(s)
- A Sanati Nezhad
- Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, 02139, USA
| |
Collapse
|
7
|
Krueger E, Claudino Junior JL, Scheeren EM, Neves EB, Mulinari E, Nohama P. Iontophoresis: principles and applications. FISIOTERAPIA EM MOVIMENTO 2014. [DOI: 10.1590/0103-5150.027.003.ar02] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Introduction Iontophoresis is a noninvasive technique used to increase transdermal penetration of substances through the skin layer (epidermis, dermis and hypodermis) in a controlled manner. Technological advance in recent decades have provided reduced cost of equipment needed for implementation, which allowed for the expansion of this technique. Objective The aim of this paper is to present the state of the art on iontophoresis, ranging from the atomic characteristics of the ion formation to the current applications of the technique. Methods Were researched papers from databases: IOP publishing, ScienceDirect, Pubmed, Springer, IEEE Xplore, Google Scholar and books with keywords iontophoresis, ions, topical applications between 1967 and 2010. Results Were selected (number of papers and database) 1 IOP Publishing, 1 from ScienceDirect, Central, 1 from Springer, 2 from PubMed, 11 from IEEE Xplore, 35 from Google Scholar, and 15 books, totaling 66 references and websites with nationally marketed electrotherapy products. Conclusion Iontophoresis is suitable for applications such as acetic acid (calcific tendinitis and myositis ossificans), calcium chloride and magnesium sulfate (control of musculoskeletal spasms), dexamethasone (inflammation), lidocaine (inflammation of soft tissues), zinc oxide (rheumatoid arthritis). It is also used in cosmetic applications with devices attached to the skin and for eye treatment aimed at specific tissues of the eye, providing a treatment option for various eye diseases, reducing the complications secondary to traditional methods of treatment. The advantages are the significant increase in the release and control of therapeutic agents, including drugs with high molecular weight. The disadvantages of iontophoresis are the complexity of the drug release system and prolonged exposure of the skin to an electrical current.
Collapse
Affiliation(s)
- Eddy Krueger
- Universidade Tecnológica Federal do Paraná, Brazil
| | | | | | | | | | - Percy Nohama
- Universidade Tecnológica Federal do Paraná, Brazil
| |
Collapse
|
8
|
Kleiner LW, Wright JC, Wang Y. Evolution of implantable and insertable drug delivery systems. J Control Release 2014; 181:1-10. [DOI: 10.1016/j.jconrel.2014.02.006] [Citation(s) in RCA: 105] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2013] [Revised: 02/06/2014] [Accepted: 02/07/2014] [Indexed: 11/28/2022]
|
9
|
Santos A, Sinn Aw M, Bariana M, Kumeria T, Wang Y, Losic D. Drug-releasing implants: current progress, challenges and perspectives. J Mater Chem B 2014; 2:6157-6182. [DOI: 10.1039/c4tb00548a] [Citation(s) in RCA: 91] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
This review presents the different types and concepts of drug-releasing implants using new nanomaterials and nanotechnology-based devices.
Collapse
Affiliation(s)
- Abel Santos
- School of Chemical Engineering
- The University of Adelaide
- 5005 Adelaide, Australia
| | - Moom Sinn Aw
- School of Chemical Engineering
- The University of Adelaide
- 5005 Adelaide, Australia
| | - Manpreet Bariana
- School of Chemical Engineering
- The University of Adelaide
- 5005 Adelaide, Australia
- School of Dentistry
- The University of Adelaide
| | - Tushar Kumeria
- School of Chemical Engineering
- The University of Adelaide
- 5005 Adelaide, Australia
| | - Ye Wang
- School of Chemical Engineering
- The University of Adelaide
- 5005 Adelaide, Australia
| | - Dusan Losic
- School of Chemical Engineering
- The University of Adelaide
- 5005 Adelaide, Australia
| |
Collapse
|
10
|
Nuxoll E. BioMEMS in drug delivery. Adv Drug Deliv Rev 2013; 65:1611-25. [PMID: 23856413 DOI: 10.1016/j.addr.2013.07.003] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2013] [Revised: 05/31/2013] [Accepted: 07/05/2013] [Indexed: 12/25/2022]
Abstract
The drive to design micro-scale medical devices which can be reliably and uniformly mass produced has prompted many researchers to adapt processing technologies from the semiconductor industry. By operating at a much smaller length scale, the resulting biologically-oriented microelectromechanical systems (BioMEMS) provide many opportunities for improved drug delivery: Low-dose vaccinations and painless transdermal drug delivery are possible through precisely engineered microneedles which pierce the skin's barrier layer without reaching the nerves. Low-power, low-volume BioMEMS pumps and reservoirs can be implanted where conventional pumping systems cannot. Drug formulations with geometrically complex, extremely uniform micro- and nano-particles are formed through micromolding or with microfluidic devices. This review describes these BioMEMS technologies and discusses their current state of implementation. As these technologies continue to develop and capitalize on their simpler integration with other MEMS-based systems such as computer controls and telemetry, BioMEMS' impact on the field of drug delivery will continue to increase.
Collapse
Affiliation(s)
- Eric Nuxoll
- Department of Chemical and Biochemical Engineering, Seamans Center for the Engineering Arts & Sciences, University of Iowa, Iowa City, IA 52245, USA.
| |
Collapse
|
11
|
Gibbs JD, Graham MW, Bascom R, Cornish DC, Khare R, Higgins WE. Optimal procedure planning and guidance system for peripheral bronchoscopy. IEEE Trans Biomed Eng 2013; 61:638-57. [PMID: 24235246 DOI: 10.1109/tbme.2013.2285627] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
With the development of multidetector computed-tomography (MDCT) scanners and ultrathin bronchoscopes, the use of bronchoscopy for diagnosing peripheral lung-cancer nodules is becoming a viable option. The work flow for assessing lung cancer consists of two phases: 1) 3-D MDCT analysis and 2) live bronchoscopy. Unfortunately, the yield rates for peripheral bronchoscopy have been reported to be as low as 14%, and bronchoscopy performance varies considerably between physicians. Recently, proposed image-guided systems have shown promise for assisting with peripheral bronchoscopy. Yet, MDCT-based route planning to target sites has relied on tedious error-prone techniques. In addition, route planning tends not to incorporate known anatomical, device, and procedural constraints that impact a feasible route. Finally, existing systems do not effectively integrate MDCT-derived route information into the live guidance process. We propose a system that incorporates an automatic optimal route-planning method, which integrates known route constraints. Furthermore, our system offers a natural translation of the MDCT-based route plan into the live guidance strategy via MDCT/video data fusion. An image-based study demonstrates the route-planning method's functionality. Next, we present a prospective lung-cancer patient study in which our system achieved a successful navigation rate of 91% to target sites. Furthermore, when compared to a competing commercial system, our system enabled bronchoscopy over two airways deeper into the airway-tree periphery with a sample time that was nearly 2 min shorter on average. Finally, our system's ability to almost perfectly predict the depth of a bronchoscope's navigable route in advance represents a substantial benefit of optimal route planning.
Collapse
|
12
|
Barkam S, Saraf S, Seal S. Fabricated micro-nano devices for in vivo and in vitro biomedical applications. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY 2013; 5:544-68. [PMID: 23894041 DOI: 10.1002/wnan.1236] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2013] [Revised: 06/04/2013] [Accepted: 06/19/2013] [Indexed: 12/11/2022]
Abstract
In recent years, the innovative use of microelectromechanical systems (MEMSs) and nanoelectromechanical systems (NEMSs) in biomedical applications has opened wide opportunities for precise and accurate human diagnostics and therapeutics. The introduction of nanotechnology in biomedical applications has facilitated the exact control and regulation of biological environments. This ability is derived from the small size of the devices and their multifunctional capabilities to operate at specific sites for selected durations of time. Researchers have developed wide varieties of unique and multifunctional MEMS/NEMS devices with micro and nano features for biomedical applications (BioMEMS/NEMS) using the state of the art microfabrication techniques and biocompatible materials. However, the integration of devices with the biological milieu is still a fundamental issue to be addressed. Devices often fail to operate due to loss of functionality, or generate adverse toxic effects inside the body. The in vitro and in vivo performance of implantable BioMEMS such as biosensors, smart stents, drug delivery systems, and actuation systems are researched extensively to understand the interaction of the BioMEMS devices with physiological environments. BioMEMS developed for drug delivery applications include microneedles, microreservoirs, and micropumps to achieve targeted drug delivery. The biocompatibility of BioMEMS is further enhanced through the application of tissue and smart surface engineering. This involves the application of nanotechnology, which includes the modification of surfaces with polymers or the self-assembly of monolayers of molecules. Thereby, the adverse effects of biofouling can be reduced and the performance of devices can be improved in in vivo and in vitro conditions.
Collapse
Affiliation(s)
- Swetha Barkam
- Advanced Materials Processing and Analysis Center, Nanoscience Technology Center, Materials Science and Engineering, University of Central Florida, Orlando, FL, USA
| | | | | |
Collapse
|
13
|
Nezhad AS, Naghavi M, Packirisamy M, Bhat R, Geitmann A. Quantification of the Young's modulus of the primary plant cell wall using Bending-Lab-On-Chip (BLOC). LAB ON A CHIP 2013; 13:2599-608. [PMID: 23571308 DOI: 10.1039/c3lc00012e] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Biomechanical and mathematical modeling of plant developmental processes requires quantitative information about the structural and mechanical properties of living cells, tissues and cellular components. A crucial mechanical property of plant cells is the mechanical stiffness or Young's modulus of its cell wall. Measuring this property in situ at single cell wall level is technically challenging. Here, a bending test is implemented in a chip, called Bending-Lab-On-a-Chip (BLOC), to quantify this biomechanical property for a widely investigated cellular model system, the pollen tube. Pollen along with culture medium is introduced into a microfluidic chip and the growing pollen tube is exposed to a bending force created through fluid loading. The flexural rigidity of the pollen tube and the Young's modulus of the cell wall are estimated through finite element modeling of the observed fluid-structure interaction. An average value of 350 MPa was experimentally estimated for the Young's modulus in longitudinal direction of the cell wall of Camellia pollen tubes. This value is in agreement with the result of an independent method based on cellular shrinkage after plasmolysis and with the mechanical properties of in vitro reconstituted cellulose-callose material.
Collapse
Affiliation(s)
- Amir Sanati Nezhad
- Optical Bio-Microsystem Lab, Mechanical Engineering Department, Concordia University, Montreal, Canada
| | | | | | | | | |
Collapse
|
14
|
Ngoepe M, Choonara YE, Tyagi C, Tomar LK, du Toit LC, Kumar P, Ndesendo VMK, Pillay V. Integration of biosensors and drug delivery technologies for early detection and chronic management of illness. SENSORS (BASEL, SWITZERLAND) 2013; 13:7680-713. [PMID: 23771157 PMCID: PMC3715220 DOI: 10.3390/s130607680] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/27/2013] [Revised: 05/21/2013] [Accepted: 06/07/2013] [Indexed: 11/17/2022]
Abstract
Recent advances in biosensor design and sensing efficacy need to be amalgamated with research in responsive drug delivery systems for building superior health or illness regimes and ensuring good patient compliance. A variety of illnesses require continuous monitoring in order to have efficient illness intervention. Physicochemical changes in the body can signify the occurrence of an illness before it manifests. Even with the usage of sensors that allow diagnosis and prognosis of the illness, medical intervention still has its downfalls. Late detection of illness can reduce the efficacy of therapeutics. Furthermore, the conventional modes of treatment can cause side-effects such as tissue damage (chemotherapy and rhabdomyolysis) and induce other forms of illness (hepatotoxicity). The use of drug delivery systems enables the lowering of side-effects with subsequent improvement in patient compliance. Chronic illnesses require continuous monitoring and medical intervention for efficient treatment to be achieved. Therefore, designing a responsive system that will reciprocate to the physicochemical changes may offer superior therapeutic activity. In this respect, integration of biosensors and drug delivery is a proficient approach and requires designing an implantable system that has a closed loop system. This offers regulation of the changes by means of releasing a therapeutic agent whenever illness biomarkers prevail. Proper selection of biomarkers is vital as this is key for diagnosis and a stimulation factor for responsive drug delivery. By detecting an illness before it manifests by means of biomarkers levels, therapeutic dosing would relate to the severity of such changes. In this review various biosensors and drug delivery systems are discussed in order to assess the challenges and future perspectives of integrating biosensors and drug delivery systems for detection and management of chronic illness.
Collapse
Affiliation(s)
- Mpho Ngoepe
- Department of Pharmacy and Pharmacology, Faculty of Health Sciences, University of the Witwatersrand, 7 York Road, Parktown, 2193, Johannesburg, South Africa; E-Mails: (M.N.); (Y.E.C.); (L.C.D.); (P.K.); (C.T.) (L.K.T.)
| | - Yahya E. Choonara
- Department of Pharmacy and Pharmacology, Faculty of Health Sciences, University of the Witwatersrand, 7 York Road, Parktown, 2193, Johannesburg, South Africa; E-Mails: (M.N.); (Y.E.C.); (L.C.D.); (P.K.); (C.T.) (L.K.T.)
| | - Charu Tyagi
- Department of Pharmacy and Pharmacology, Faculty of Health Sciences, University of the Witwatersrand, 7 York Road, Parktown, 2193, Johannesburg, South Africa; E-Mails: (M.N.); (Y.E.C.); (L.C.D.); (P.K.); (C.T.) (L.K.T.)
| | - Lomas Kumar Tomar
- Department of Pharmacy and Pharmacology, Faculty of Health Sciences, University of the Witwatersrand, 7 York Road, Parktown, 2193, Johannesburg, South Africa; E-Mails: (M.N.); (Y.E.C.); (L.C.D.); (P.K.); (C.T.) (L.K.T.)
| | - Lisa C. du Toit
- Department of Pharmacy and Pharmacology, Faculty of Health Sciences, University of the Witwatersrand, 7 York Road, Parktown, 2193, Johannesburg, South Africa; E-Mails: (M.N.); (Y.E.C.); (L.C.D.); (P.K.); (C.T.) (L.K.T.)
| | - Pradeep Kumar
- Department of Pharmacy and Pharmacology, Faculty of Health Sciences, University of the Witwatersrand, 7 York Road, Parktown, 2193, Johannesburg, South Africa; E-Mails: (M.N.); (Y.E.C.); (L.C.D.); (P.K.); (C.T.) (L.K.T.)
| | - Valence M. K. Ndesendo
- School of Pharmacy and Pharmaceutical Sciences, St. John's University of Tanzania, Dodoma, Tanzania; E-Mail:
| | - Viness Pillay
- Department of Pharmacy and Pharmacology, Faculty of Health Sciences, University of the Witwatersrand, 7 York Road, Parktown, 2193, Johannesburg, South Africa; E-Mails: (M.N.); (Y.E.C.); (L.C.D.); (P.K.); (C.T.) (L.K.T.)
| |
Collapse
|
15
|
Agudelo CG, Sanati Nezhad A, Ghanbari M, Naghavi M, Packirisamy M, Geitmann A. TipChip: a modular, MEMS-based platform for experimentation and phenotyping of tip-growing cells. THE PLANT JOURNAL : FOR CELL AND MOLECULAR BIOLOGY 2013; 73:1057-68. [PMID: 23217059 DOI: 10.1111/tpj.12093] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2012] [Revised: 11/23/2012] [Accepted: 12/05/2012] [Indexed: 05/20/2023]
Abstract
Large-scale phenotyping of tip-growing cells such as pollen tubes has hitherto been limited to very crude parameters such as germination percentage and velocity of growth. To enable efficient and high-throughput execution of more sophisticated assays, an experimental platform, the TipChip, was developed based on microfluidic and microelectromechanical systems (MEMS) technology. The device allows positioning of pollen grains or fungal spores at the entrances of serially arranged microchannels equipped with microscopic experimental set-ups. The tip-growing cells (pollen tubes, filamentous yeast or fungal hyphae) may be exposed to chemical gradients, microstructural features, integrated biosensors or directional triggers within the modular microchannels. The device is compatible with Nomarski optics and fluorescence microscopy. Using this platform, we were able to answer several outstanding questions on pollen tube growth. We established that, unlike root hairs and fungal hyphae, pollen tubes do not have a directional memory. Furthermore, pollen tubes were found to be able to elongate in air, raising the question of how and where water is taken up by the cell. The platform opens new avenues for more efficient experimentation and large-scale phenotyping of tip-growing cells under precisely controlled, reproducible conditions.
Collapse
Affiliation(s)
- Carlos G Agudelo
- Optical Bio-Microsystem Laboratory, Mechanical Engineering Department, Concordia University, Montreal, QC, Canada
| | | | | | | | | | | |
Collapse
|
16
|
Stevenson CL, Santini JT, Langer R. Reservoir-based drug delivery systems utilizing microtechnology. Adv Drug Deliv Rev 2012; 64:1590-602. [PMID: 22465783 DOI: 10.1016/j.addr.2012.02.005] [Citation(s) in RCA: 137] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2011] [Revised: 02/09/2012] [Accepted: 02/15/2012] [Indexed: 11/30/2022]
Abstract
This review covers reservoir-based drug delivery systems that incorporate microtechnology, with an emphasis on oral, dermal, and implantable systems. Key features of each technology are highlighted such as working principles, fabrication methods, dimensional constraints, and performance criteria. Reservoir-based systems include a subset of microfabricated drug delivery systems and provide unique advantages. Reservoirs, whether external to the body or implanted, provide a well-controlled environment for a drug formulation, allowing increased drug stability and prolonged delivery times. Reservoir systems have the flexibility to accommodate various delivery schemes, including zero order, pulsatile, and on demand dosing, as opposed to a standard sustained release profile. Furthermore, the development of reservoir-based systems for targeted delivery for difficult to treat applications (e.g., ocular) has resulted in potential platforms for patient therapy.
Collapse
Affiliation(s)
- Cynthia L Stevenson
- On Demand Therapeutics, Inc., One Industrial Way, Unit 1A, Tyngsboro, MA 01879, USA.
| | | | | |
Collapse
|
17
|
Meng E, Hoang T. MEMS-enabled implantable drug infusion pumps for laboratory animal research, preclinical, and clinical applications. Adv Drug Deliv Rev 2012; 64:1628-38. [PMID: 22926321 DOI: 10.1016/j.addr.2012.08.006] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2011] [Revised: 04/30/2012] [Accepted: 08/02/2012] [Indexed: 02/06/2023]
Abstract
Innovation in implantable drug delivery devices is needed for novel pharmaceutical compounds such as certain biologics, gene therapy, and other small molecules that are not suitable for administration by oral, topical, or intravenous routes. This invasive dosing scheme seeks to directly bypass physiological barriers presented by the human body, release the appropriate drug amount at the site of treatment, and maintain the drug bioavailability for the required duration of administration to achieve drug efficacy. Advances in microtechnologies have led to novel MEMS-enabled implantable drug infusion pumps with unique performance and feature sets. In vivo demonstration of micropumps for laboratory animal research and preclinical studies include acute rapid radiolabeling, short-term delivery of nanomedicine for cancer treatment, and chronic ocular drug dosing. Investigation of MEMS actuators, valves, and other microstructures for on-demand dosing control may enable next generation implantable pumps with high performance within a miniaturized form factor for clinical applications.
Collapse
|
18
|
Louizos LA, Athanasopoulos PG, Varty K. Microelectromechanical systems and nanotechnology: a platform for the next stent technological era. Vasc Endovascular Surg 2012; 46:605-9. [PMID: 23047818 DOI: 10.1177/1538574412462637] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Nanotechnology is the design and development of materials, structures, and devices with at least 1 dimension between the 1- and 100-nm-size scale. Manipulating matter at the atomic scale offers unique opportunities in material design particularly in biological interfaces. In this short review, we explore the disruptive technological opportunities that nanotechnology and microelectromechanical systems may offer in possible future stent designs along with safety issues that may surface with the use of nanoparticles in medical devices.
Collapse
Affiliation(s)
- Louizos-Alexandros Louizos
- Department of Vascular Surgery, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK.
| | | | | |
Collapse
|
19
|
Bogie K, Powell HL, Ho CH. New concepts in the prevention of pressure sores. HANDBOOK OF CLINICAL NEUROLOGY 2012; 109:235-246. [PMID: 23098716 DOI: 10.1016/b978-0-444-52137-8.00014-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Pressure sores are a serious, and costly, complication for many patients with reduced mobility and sensation. Some populations, such as those with spinal cord injury (SCI), remain at high risk throughout their lifetime. Prevention is highly preferable and while the concept is readily definable, it is much more challenging to develop valid preventative measures. Subjective and objective approaches to risk factor assessment before pressure sores develop are reviewed, including risk status scales and emerging techniques to assess deep tissue injury. Devices to prevent pressure sores have traditionally focused on pressure-relieving cushions and mattresses. Technological advances being applied in the development of new pressure sore prevention devices are presented. Clinical evidence-based practice is integral to pressure sore prevention. Comprehensive assessment must include evaluation of systemic diseases, anatomical and physiological factors, together with environmental and psychosocial factors, which can all contribute to pressure sore development. Extrinsic factors need to be considered in conjunction with intrinsic tissue health factors and are reviewed together with an evaluation of currently available clinical practice guidelines. This chapter presents the broad diversity of factors associated with pressure sore development and highlights the need for an interdisciplinary team approach in order to maximize successful prevention of pressure sores.
Collapse
Affiliation(s)
- Kath Bogie
- Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH, USA.
| | | | | |
Collapse
|
20
|
Affiliation(s)
- Faisal M. Merchant
- From the Cardiology Division (F.M.M.), Emory University School of Medicine, Atlanta, Ga; and the Cardiology Division (G.W.D., J.P.S.), Massachusetts General Hospital Heart Center, Harvard Medical School, Boston, Mass
| | - G. William Dec
- From the Cardiology Division (F.M.M.), Emory University School of Medicine, Atlanta, Ga; and the Cardiology Division (G.W.D., J.P.S.), Massachusetts General Hospital Heart Center, Harvard Medical School, Boston, Mass
| | - Jagmeet P. Singh
- From the Cardiology Division (F.M.M.), Emory University School of Medicine, Atlanta, Ga; and the Cardiology Division (G.W.D., J.P.S.), Massachusetts General Hospital Heart Center, Harvard Medical School, Boston, Mass
| |
Collapse
|
21
|
Grattoni A, Shen H, Fine D, Ziemys A, Gill JS, Hudson L, Hosali S, Goodall R, Liu X, Ferrari M. Nanochannel Technology for Constant Delivery of Chemotherapeutics: Beyond Metronomic Administration. Pharm Res 2010; 28:292-300. [DOI: 10.1007/s11095-010-0195-6] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2010] [Accepted: 06/11/2010] [Indexed: 11/27/2022]
|
22
|
Wang PC, Wester BA, Rajaraman S, Paik SJ, Kim SH, Allen MG. Hollow polymer microneedle array fabricated by photolithography process combined with micromolding technique. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2010; 2009:7026-9. [PMID: 19964192 DOI: 10.1109/iembs.2009.5333317] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Transdermal drug delivery through microneedles is a minimally invasive procedure causing little or no pain, and is a potentially attractive alternative to intramuscular and subdermal drug delivery methods. This paper demonstrates the fabrication of a hollow microneedle array using a polymer-based process combining UV photolithography and replica molding techniques. The key characteristic of the proposed fabrication process is to define a hollow lumen for microfluidic access via photopatterning, allowing a batch process as well as high throughput. A hollow SU-8 microneedle array, consisting of 825mum tall and 400 mum wide microneedles with 15-25 mum tip diameters and 120 mum diameter hollow lumens was designed, fabricated and characterized.
Collapse
Affiliation(s)
- Po-Chun Wang
- School of Electrical and Computer Engineering of Georgia Institute of Technology, Atlanta, GA 30332, USA.
| | | | | | | | | | | |
Collapse
|
23
|
Sakamoto JH, van de Ven AL, Godin B, Blanco E, Serda RE, Grattoni A, Ziemys A, Bouamrani A, Hu T, Ranganathan SI, De Rosa E, Martinez JO, Smid CA, Buchanan RM, Lee SY, Srinivasan S, Landry M, Meyn A, Tasciotti E, Liu X, Decuzzi P, Ferrari M. Enabling individualized therapy through nanotechnology. Pharmacol Res 2010; 62:57-89. [PMID: 20045055 DOI: 10.1016/j.phrs.2009.12.011] [Citation(s) in RCA: 152] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2009] [Accepted: 12/21/2009] [Indexed: 12/13/2022]
Abstract
Individualized medicine is the healthcare strategy that rebukes the idiomatic dogma of 'losing sight of the forest for the trees'. We are entering a new era of healthcare where it is no longer acceptable to develop and market a drug that is effective for only 80% of the patient population. The emergence of "-omic" technologies (e.g. genomics, transcriptomics, proteomics, metabolomics) and advances in systems biology are magnifying the deficiencies of standardized therapy, which often provide little treatment latitude for accommodating patient physiologic idiosyncrasies. A personalized approach to medicine is not a novel concept. Ever since the scientific community began unraveling the mysteries of the genome, the promise of discarding generic treatment regimens in favor of patient-specific therapies became more feasible and realistic. One of the major scientific impediments of this movement towards personalized medicine has been the need for technological enablement. Nanotechnology is projected to play a critical role in patient-specific therapy; however, this transition will depend heavily upon the evolutionary development of a systems biology approach to clinical medicine based upon "-omic" technology analysis and integration. This manuscript provides a forward looking assessment of the promise of nanomedicine as it pertains to individualized medicine and establishes a technology "snapshot" of the current state of nano-based products over a vast array of clinical indications and range of patient specificity. Other issues such as market driven hurdles and regulatory compliance reform are anticipated to "self-correct" in accordance to scientific advancement and healthcare demand. These peripheral, non-scientific concerns are not addressed at length in this manuscript; however they do exist, and their impact to the paradigm shifting healthcare transformation towards individualized medicine will be critical for its success.
Collapse
Affiliation(s)
- Jason H Sakamoto
- The University of Texas Health Science Center, Department of Nanomedicine and Biomedical Engineering, Houston, TX 77030, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Qin G, Zhang R, Makarenko B, Kumar A, Rabalais W, López Romero JM, Rico R, Cai C. Highly stable, protein resistant thin films on SiC-modified silicon substrates. Chem Commun (Camb) 2010; 46:3289-91. [DOI: 10.1039/b925708j] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|