1
|
Liu H, Meng Y. Microwave Sensor for Dielectric Constant of Lossy Organic Liquids Based on Negative-Resistance Oscillation. SENSORS (BASEL, SWITZERLAND) 2025; 25:961. [PMID: 39943600 PMCID: PMC11820851 DOI: 10.3390/s25030961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/01/2025] [Revised: 01/23/2025] [Accepted: 01/25/2025] [Indexed: 02/16/2025]
Abstract
The dielectric constant, or permittivity, is a fundamental property that characterizes a material's electromagnetic behavior, crucial for diverse applications in agriculture, healthcare, industry, and scientific research. In microwave engineering, accurate permittivity measurement is essential for advancements in fields such as biomedicine, aerospace, and microwave chemistry. However, conventional waveguide resonator methods face challenges when measuring high-loss materials, often leading to reduced accuracy and increased cost. This paper introduces a lightweight, compact system for dielectric constant measurement using a negative-resistance voltage-controlled oscillator (VCO) integrated within a frequency synthesizer. The proposed system employs phase response variations of a planar sensor embedded in the VCO's gate network to detect changes in oscillation frequency, enabling precise measurement of high-loss materials. The experimental validation demonstrates the system's capability to accurately measure dielectric constants of lossy organic liquids, with applications in distinguishing liquid mixtures. The contributions include the design of a resonant-network-attached oscillator, comprehensive sensor performance simulations, and successful characterization of organic liquid mixtures, showcasing the potential of this approach for practical dielectric property measurements.
Collapse
Affiliation(s)
- Huan Liu
- Institute of Fiber Optics, Shanghai University, Shanghai 201800, China;
- Key Laboratory of Specialty Fiber Optics and Optical Access Networks, Joint International Research Laboratory of Specialty Fiber Optics and Advanced Communication, Shanghai University, Shanghai 20044, China
| | - Yichao Meng
- Institute of Fiber Optics, Shanghai University, Shanghai 201800, China;
- Key Laboratory of Specialty Fiber Optics and Optical Access Networks, Joint International Research Laboratory of Specialty Fiber Optics and Advanced Communication, Shanghai University, Shanghai 20044, China
| |
Collapse
|
2
|
Lu TC, Lin YT, Xiao WB, Qiu QZ, Tian HY, Lei Y, Liu AL. Reagent-free anti-fouling electrochemical immunosensor based on AL-BSA/AuNPs/PANI coating for the point-of-care detection of C-reactive protein in plasma and whole blood. Biosens Bioelectron 2024; 264:116667. [PMID: 39146772 DOI: 10.1016/j.bios.2024.116667] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2024] [Revised: 07/29/2024] [Accepted: 08/11/2024] [Indexed: 08/17/2024]
Abstract
Developing the portable CRP detection technologies that are suitable for point-of-care (POC) and primary care management is of utmost importance, and advancing the electrochemical immunosensors hold promise for POC implementation. Nevertheless, non-specific adsorption of numerous interfering proteins in complex biological media contaminates immunosensors, thereby restricting the reliability in detection efficacy. In this study, a three-dimensional flower-leaf shape amyloid bovine serum albumin/gold nanoparticles/polyaniline (AL-BSA/AuNPs/PANI) coating on the surface of the electrode was developed, which demonstrated strong anti-adsorption properties against bovine serum albumin, plasma, and cells. The immunosensor exhibited a good linear relationship to CRP response, featuring a detection limit of 0.09 μg/mL, consistent with clinical reference range. In addition, the CRP immunosensor demonstrated excellent specificity in other inflammation-related proteins and commendable anti-interference performance for CRP detection in plasma and whole blood tests. Importantly, by combining the development of a USB flash disk-type portable electrochemical workstation with a reagent-free mode, the developed CRP electrochemical immunosensor delivered ideal results in clinical samples. The anti-fouling performance, sensitivity and specificity of the immunosensor, as well as its flexible test modes in clinical samples, provide important scientific basis for developing POC detection technologies of vital biomarkers in complex biological media.
Collapse
Affiliation(s)
- Tai-Cheng Lu
- Department of Pharmaceutical Analysis, Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, The School of Pharmacy, Fujian Medical University, Fuzhou, 350122, China
| | - Yi-Ting Lin
- Department of Pharmaceutical Analysis, Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, The School of Pharmacy, Fujian Medical University, Fuzhou, 350122, China
| | - Wen-Biao Xiao
- Department of Critical Care Medicine, The First Affiliated Hospital, Fujian Medical University, Fujian, Fuzhou, China
| | - Qing-Zhen Qiu
- Department of Pharmaceutical Analysis, Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, The School of Pharmacy, Fujian Medical University, Fuzhou, 350122, China
| | - Hui-Yun Tian
- Fujian Institute of Hematology, The Affiliated Union Hospital of Fujian Medical University, Fuzhou, 350000, China
| | - Yun Lei
- Department of Pharmaceutical Analysis, Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, The School of Pharmacy, Fujian Medical University, Fuzhou, 350122, China.
| | - Ai-Lin Liu
- Department of Pharmaceutical Analysis, Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, The School of Pharmacy, Fujian Medical University, Fuzhou, 350122, China.
| |
Collapse
|
3
|
Li Y. A voltage mode grounded capacitance multiplier with widely tunable gain for ultra-low cutoff frequency filter. Sci Prog 2024; 107:368504241276765. [PMID: 39351651 PMCID: PMC11450714 DOI: 10.1177/00368504241276765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/06/2024]
Abstract
A voltage mode capacitance multiplier for ultra-low frequency physiological signal processing is designed with a circuit model. With the proposed multiplier, a filter can achieve a cutoff frequency of 12 mHz with a 1 pF basic capacitance and a 10 kΩ resistor. The corresponding multiplication factor will be 1.35 × 109. By changing the controlling terminal, the multiplication factor can be widely tuned from 1950 to 1.35 × 109 and the corresponding filter cutoff frequency will be from 12 mHz to 8.15 kHz. According to the circuit model, to further increase the multiplication factor to decrease the chip area, more multiplication stages can be added to the feedback loop.
Collapse
Affiliation(s)
- Yan Li
- School of Applied Science, Beijing Information Science and Technology University, Beijing, P.R. China
| |
Collapse
|
4
|
Lee SY, Hsieh YT, Lee HY, Chang SS, Chen JY. A Direct Current-Sensing VCO-Based 2nd-Order Continuous-Time Sigma-Delta Modulator for Biosensor Readout Applications. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2024; 18:288-298. [PMID: 37812555 DOI: 10.1109/tbcas.2023.3322901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/11/2023]
Abstract
A second-order voltage-controlled oscillator (VCO)-based continuous-time sigma-delta modulator (CTSDM) for current-sensing readout applications is proposed. Current signals from the sensor can directly be quantized by the proposed VCO-based CTSDM, which does not require any extra trans-impedance amplifiers. With the proportional-integral (PI) structure and a VCO phase integrator, the capability of second-order noise shaping is available to reduce the in-band quantization noise. The PI structure can be simply realized by a resistor in series with the integrating capacitor, which can reduce the architecture complexity and maintain the stability of the system. The current-steering digital-to-analog converter with tail and sink current sources is used on the feedback path for the subtraction of the current-type input signal. All the components of the circuit are scaling friendly and applicable to current-sensing readout applications in the Internet of Things (IoT). The proposed VCO-based CTSDM implemented in a 0.18-μm standard CMOS process has a measured signal-to-noise and distortion ratio (SNDR) of 74.6 dB at 10 kHz bandwidth and consumes 44.8 μw only under a supply voltage of 1.2 V, which can achieve a Figure-of-Merit (FoM) of 160.76 dB.
Collapse
|
5
|
Indah Wardani N, Kanatharana P, Thavarungkul P, Limbut W. Molecularly imprinted polymer dual electrochemical sensor for the one-step determination of albuminuria to creatinine ratio (ACR). Talanta 2023; 265:124769. [PMID: 37329752 DOI: 10.1016/j.talanta.2023.124769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 06/02/2023] [Accepted: 06/04/2023] [Indexed: 06/19/2023]
Abstract
The urinary albumin to creatinine ratio (ACR) is a convenient and accurate biomarker of chronic kidney disease (CKD). An electrochemical sensor for the quantification of ACR was developed based on a dual screen-printed carbon electrode (SPdCE). The SPdCE was modified with carboxylated multiwalled carbon nanotubes (f-MWCNTs) and redox probes of polymethylene blue (PMB) for creatinine and ferrocene (Fc) for albumin. The modified working electrodes were then molecularly imprinted with coated with polymerized poly-o-phenylenediamine (PoPD) to form surfaces that could be separately imprinted with creatinine and albumin template molecules. The seeded polymer layers were polymerized with a second coating of PoPD and the templates were removed to form two different molecularly imprinted polymer (MIP) layers. The dual sensor presented recognition sites for creatinine and albumin on different working electrodes, enabling the measurement of each analyte in one potential scan of square wave voltammetry (SWV). The proposed sensor produced linear ranges of 5.0-100 ng mL-1 and 100-2500 ng mL-1 for creatinine, and 5.0-100 ng mL-1 for albumin. LODs were 1.5 ± 0.2 ng mL-1 and 1.5 ± 0.3 ng mL-1, respectively. The dual MIP sensor was highly selective and stable for seven weeks at room temperature. The ACRs obtained using the proposed sensor compared well (P > 0.05) with the results from immunoturbidimetric and enzymatic methods.
Collapse
Affiliation(s)
- Nur Indah Wardani
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Proespichaya Kanatharana
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Panote Thavarungkul
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Warakorn Limbut
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.
| |
Collapse
|
6
|
Lin SY, Lin CY. Electrochemically-functionalized CNT/ABTS nanozyme enabling sensitive and selective voltammetric detection of microalbuminuria. Anal Chim Acta 2022; 1197:339517. [DOI: 10.1016/j.aca.2022.339517] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2021] [Revised: 01/11/2022] [Accepted: 01/17/2022] [Indexed: 11/01/2022]
|