1
|
Davidson B, Lozano AM. Focused ultrasound: focused on tremor. Expert Rev Med Devices 2025:1-9. [PMID: 40184524 DOI: 10.1080/17434440.2025.2489493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2024] [Revised: 03/10/2025] [Accepted: 04/02/2025] [Indexed: 04/06/2025]
Abstract
INTRODUCTION Magnetic resonance-guided focused ultrasound (MRgFUS) has emerged as a leading noninvasive therapy for tremor, offering a precise, lesion-based alternative to deep brain stimulation (DBS) and traditional lesioning techniques. By using phased ultrasound arrays to focus energy at intracranial targets, MRgFUS allows for real-time visualization and monitoring, improving safety and efficacy. Initially developed for essential tremor (ET), MRgFUS-VIM-thalamotomy has gained widespread acceptance and is now a first-line option for tremor-dominant Parkinson's disease (TDPD) and other tremor syndromes. AREAS COVERED This review discusses the fundamental physics of focused ultrasound, key anatomical targets, and the clinical application of MRgFUS thalamotomy, pallidotomy, and subthalamotomy. Skull density ratio (SDR) and energy efficiency are highlighted as crucial factors affecting treatment outcomes. The evolution of MRgFUS as a bilateral treatment, along with the exploration of novel targets such as the pallidothalamic tract, is examined. Additionally, we discuss advancements in FUS neuromodulation, which could complement lesioning by providing temporary or reversible symptom relief. EXPERT OPINION MRgFUS is poised to further revolutionize tremor treatment with frameless technology, staged bilateral procedures, and the integration of neuromodulation. Future developments may allow for precise, adaptive therapies that enhance both efficacy and patient experience.
Collapse
Affiliation(s)
- Benjamin Davidson
- Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, Canada
- Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Canada
| | - Andres M Lozano
- Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, Canada
- Krembil Research Institute, University Health Network, Toronto, ON, Canada
| |
Collapse
|
2
|
Noel RL, Kugelman T, Karakatsani ME, Shahriar S, Willner MJ, Choi CS, Nimi Y, Ji R, Agalliu D, Konofagou EE. Safe focused ultrasound-mediated blood-brain barrier opening is driven primarily by transient reorganization of tight junctions. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2025:2025.01.28.635258. [PMID: 39975117 PMCID: PMC11838333 DOI: 10.1101/2025.01.28.635258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/21/2025]
Abstract
Focused ultrasound (FUS) with microbubbles opens the blood-brain barrier (BBB) to allow targeted drug delivery into the brain. The mechanisms by which endothelial cells (ECs) respond to either low acoustic pressures known to open the BBB transiently, or high acoustic pressures that cause brain damage, remain incompletely characterized. Here, we use a mouse strain where tight junctions between ECs are labelled with eGFP and apply FUS at low (450 kPa) and high (750 kPa) acoustic pressures, after which mice are sacrificed at 1 or 72 hours. We find that the EC response leading to FUS-mediated BBB opening at low pressures is localized primarily in arterioles and capillaries, and characterized by a transient loss and reorganization of tight junctions. BBB opening still occurs at low safe pressures in mice lacking caveolae, suggesting that it is driven primarily by transient dismantlement and reorganization of tight junctions. In contrast, BBB opening at high pressures is associated with obliteration of EC tight junctions that remain unrepaired even after 72 hours, allowing continuous fibrinogen passage and persistent microglial activation. Single-cell RNA-sequencing of arteriole, capillary and venule ECs from FUS mice reveals that the transcriptomic responses of ECs exposed to high pressure are dominated by genes belonging to the stress response and cell junction disassembly at both 1 and 72 hours, while lower pressures induce primarily genes responsible for intracellular repair responses in ECs. Our findings suggest that at low pressures transient reorganization of tight junctions and repair responses mediate safe BBB opening for therapeutic delivery. Significance Statement Focused ultrasound with microbubbles is used as a noninvasive method to safely open the BBB at low acoustic pressures for therapeutic delivery into the CNS, but the mechanisms mediating this process remain unclear. Kugelman et al., demonstrate that FUS-mediated BBB opening at low pressures occurs primarily in arterioles and capillaries due to transient reorganization of tight junctions. BBB opening still occurs at low safe pressures in mice lacking caveolae, suggesting a transcellular route-independent mechanism. At high unsafe pressures, cell junctions are obliterated and remain unrepaired even after 72 hours, allowing fibrinogen passage and persistent microglial activation. Single-cell RNA-sequencing supports cell biological findings that safe, FUS-mediated BBB opening may be driven by transient reorganization and repair of EC tight junctions.
Collapse
|
3
|
Șovrea AS, Boșca AB, Dronca E, Constantin AM, Crintea A, Suflețel R, Ștefan RA, Ștefan PA, Onofrei MM, Tschall C, Crivii CB. Non-Drug and Non-Invasive Therapeutic Options in Alzheimer's Disease. Biomedicines 2025; 13:84. [PMID: 39857667 PMCID: PMC11760896 DOI: 10.3390/biomedicines13010084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2024] [Revised: 12/28/2024] [Accepted: 12/29/2024] [Indexed: 01/27/2025] Open
Abstract
Despite the massive efforts of modern medicine to stop the evolution of Alzheimer's disease (AD), it affects an increasing number of people, changing individual lives and imposing itself as a burden on families and the health systems. Considering that the vast majority of conventional drug therapies did not lead to the expected results, this review will discuss the newly developing therapies as an alternative in the effort to stop or slow AD. Focused Ultrasound (FUS) and its derived Transcranial Pulse Stimulation (TPS) are non-invasive therapeutic approaches. Singly or as an applied technique to change the permeability of the blood-brain-barrier (BBB), FUS and TPS have demonstrated the benefits of use in treating AD in animal and human studies. Adipose-derived stem Cells (ADSCs), gene therapy, and many other alternative methods (diet, sleep pattern, physical exercise, nanoparticle delivery) are also new potential treatments since multimodal approaches represent the modern trend in this disorder research therapies.
Collapse
Affiliation(s)
- Alina Simona Șovrea
- Morpho-Functional Sciences Department, Iuliu Hațieganu University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania; (A.S.Ș.); (A.-M.C.); (R.S.); (R.A.Ș.); (M.M.O.); (C.-B.C.)
| | - Adina Bianca Boșca
- Morpho-Functional Sciences Department, Iuliu Hațieganu University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania; (A.S.Ș.); (A.-M.C.); (R.S.); (R.A.Ș.); (M.M.O.); (C.-B.C.)
| | - Eleonora Dronca
- Molecular Sciences Department, Iuliu Hațieganu University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania; (E.D.); (A.C.)
| | - Anne-Marie Constantin
- Morpho-Functional Sciences Department, Iuliu Hațieganu University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania; (A.S.Ș.); (A.-M.C.); (R.S.); (R.A.Ș.); (M.M.O.); (C.-B.C.)
| | - Andreea Crintea
- Molecular Sciences Department, Iuliu Hațieganu University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania; (E.D.); (A.C.)
| | - Rada Suflețel
- Morpho-Functional Sciences Department, Iuliu Hațieganu University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania; (A.S.Ș.); (A.-M.C.); (R.S.); (R.A.Ș.); (M.M.O.); (C.-B.C.)
| | - Roxana Adelina Ștefan
- Morpho-Functional Sciences Department, Iuliu Hațieganu University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania; (A.S.Ș.); (A.-M.C.); (R.S.); (R.A.Ș.); (M.M.O.); (C.-B.C.)
| | - Paul Andrei Ștefan
- Radiology and Imaging Department, Emergency County Hospital Cluj, 400347 Cluj-Napoca, Romania;
| | - Mădălin Mihai Onofrei
- Morpho-Functional Sciences Department, Iuliu Hațieganu University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania; (A.S.Ș.); (A.-M.C.); (R.S.); (R.A.Ș.); (M.M.O.); (C.-B.C.)
| | - Christoph Tschall
- Morpho-Functional Sciences Department, Iuliu Hațieganu University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania; (A.S.Ș.); (A.-M.C.); (R.S.); (R.A.Ș.); (M.M.O.); (C.-B.C.)
| | - Carmen-Bianca Crivii
- Morpho-Functional Sciences Department, Iuliu Hațieganu University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania; (A.S.Ș.); (A.-M.C.); (R.S.); (R.A.Ș.); (M.M.O.); (C.-B.C.)
| |
Collapse
|
4
|
Seo M, Shin M, Noh G, Yoo SS, Yoon K. Multi-modal networks for real-time monitoring of intracranial acoustic field during transcranial focused ultrasound therapy. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 257:108458. [PMID: 39437458 DOI: 10.1016/j.cmpb.2024.108458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2024] [Revised: 09/22/2024] [Accepted: 10/07/2024] [Indexed: 10/25/2024]
Abstract
BACKGROUND AND OBJECTIVE Transcranial focused ultrasound (tFUS) is an emerging non-invasive therapeutic technology that offers new brain stimulation modality. Precise localization of the acoustic focus to the desired brain target throughout the procedure is needed to ensure the safety and effectiveness of the treatment, but acoustic distortion caused by the skull poses a challenge. Although computational methods can provide the estimated location and shape of the focus, the computation has not reached sufficient speed for real-time inference, which is demanded in real-world clinical situations. Leveraging the advantages of deep learning, we propose multi-modal networks capable of generating intracranial pressure map in real-time. METHODS The dataset consisted of free-field pressure maps, intracranial pressure maps, medical images, and transducer placements was obtained from 11 human subjects. The free-field and intracranial pressure maps were computed using the k-space method. We developed network models based on convolutional neural networks and the Swin Transformer, featuring a multi-modal encoder and a decoder. RESULTS Evaluations on foreseen data achieved high focal volume conformity of approximately 93% for both computed tomography (CT) and magnetic resonance (MR) data. For unforeseen data, the networks achieved the focal volume conformity of 88% for CT and 82% for MR. The inference time of the proposed networks was under 0.02 s, indicating the feasibility for real-time simulation. CONCLUSIONS The results indicate that our networks can effectively and precisely perform real-time simulation of the intracranial pressure map during tFUS applications. Our work will enhance the safety and accuracy of treatments, representing significant progress for low-intensity focused ultrasound (LIFU) therapies.
Collapse
Affiliation(s)
- Minjee Seo
- Yonsei University, School of Mathematics and Computing (Computational Science and Engineering), Seoul, 03722, Republic of Korea
| | - Minwoo Shin
- Yonsei University, School of Mathematics and Computing (Computational Science and Engineering), Seoul, 03722, Republic of Korea
| | - Gunwoo Noh
- Korea University, School of Mechanical Engineering, Seoul, 02841, Republic of Korea
| | - Seung-Schik Yoo
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, 02115, MA, USA
| | - Kyungho Yoon
- Yonsei University, School of Mathematics and Computing (Computational Science and Engineering), Seoul, 03722, Republic of Korea.
| |
Collapse
|
5
|
Goudarzi S, Jones RM, Lee YHW, Hynynen K. Transducer module apodization to reduce bone heating during focused ultrasound uterine fibroid ablation with phased arrays: A numerical study. Med Phys 2024; 51:8670-8687. [PMID: 39341358 DOI: 10.1002/mp.17427] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 08/29/2024] [Accepted: 09/05/2024] [Indexed: 10/01/2024] Open
Abstract
BACKGROUND During magnetic resonance-guided focused ultrasound (MRgFUS) surgery for uterine fibroids, ablation of fibrous tissues in proximity to the hips and spine is challenging due to heating within the bone that can cause patients to experience pain and potentially damage nerves. This far-field bone heating limits the volume of fibroid tissue that is treatable via MRgFUS. PURPOSE To investigate transducer module apodization for improving the ratio of focal-to-bone heating (Δ T ratio $\Delta T_{\mathrm{ratio}}$ ) when targeting fibroid tissue close to the hips and spine, to enable MRgFUS treatments closer to the bone. METHODS Acoustic and thermal simulations were performed using 3D magnetic resonance imaging (MRI)-derived anatomies of ten patients who underwent MRgFUS ablation for uterine fibroids using a low-frequency (0.5 MHz $0.5 \ \text{MHz}$ ) 6144-element flat fully-populated modular phased array system (Arrayus Technologies Inc., Burlington, Canada) at our institution as part of a larger clinical trial (NCT03323905). Transducer modules (64 elements $64 \ \text{elements}$ per module) whose beams intersected with no-pass zones delineated within the field were identified, their output power levels were reduced by varying blocking percentage levels, and the resulting temperature field distributions were evaluated across multiple sonications near the hip and spine bones in each patient. Acoustic and thermal simulations took approximately20 min $20 \ \text{min}$ (7 min $7 \ \text{min}$ ) and1 min $1 \ \text{min}$ (30 s $30 \ \text{s}$ ) to run for a single near-spine (near-hip) target, respectively. RESULTS For all simulated sonications, transducer module blocking improvedΔ T ratio $\Delta T_{\mathrm{ratio}}$ compared to the no blocking case. In just over half of sonications, full module blocking maximizedΔ T ratio $\Delta T_{\mathrm{ratio}}$ (increase of 82% ± $\pm$ 38% in 50% of hip targets and 49% ± $\pm$ 30% in 62% of spine targets vs. no blocking; mean ± SD), at the cost of more diffuse focusing (focal heating volumes increased by 13% ± 13% for hip targets and 39% ± 27% for spine targets) and thus requiring elevated total (hip: 6% ± 17%, spine: 37% ± 17%) and peak module-wise (hip: 65% ± 36%, spine: 101% ± 56%) acoustic power levels to achieve equivalent focal heating as the no blocking control case. In the remaining sonications, partial module blocking provided further improvements in bothΔ T ratio $\Delta T_{\mathrm{ratio}}$ (increased by 29% ± 25% in the hip and 15% ± 12% in the spine) and focal heating volume (decrease of 20% ± 10% in the hip and 34% ± 17% in the spine) relative to the full blocking case. The optimal blocking percentage value was dependent on the specific patient geometry and target location of interest. Although not all individual target locations saw the benefit, element-wise phase aberration corrections improved the averageΔ T ratio $\Delta T_{\mathrm{ratio}}$ compared to the no correction case (increase of 52% ± 47% in the hip, 35% ± 24% in the spine) and impacted the optimal blocking percentage value. Transducer module blocking enabled ablative treatments to be carried out closer to both hip and spine without overheating or damaging the bone (no blocking:42 ± 1 mm $42\pm 1 \ \text{mm}$ /17 ± 2 mm $17 \pm 2 \ \text{mm}$ , full blocking:38 ± 1 mm $38\pm 1 \ \text{mm}$ /8 ± 1 mm $8\pm 1 \ \text{mm}$ , optimal partial blocking:36 ± 1 mm $36\pm 1 \ \text{mm}$ /7 ± 1 mm $7\pm 1 \ \text{mm}$ for hip/spine). CONCLUSION The proposed transducer apodization scheme shows promise for improving MRgFUS treatments of uterine fibroids, and may ultimately increase the effective treatment envelope of MRgFUS surgery in the body by enabling tissue ablation closer to bony structures.
Collapse
Affiliation(s)
- Sobhan Goudarzi
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Ryan Matthew Jones
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Yin Hau Wallace Lee
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Kullervo Hynynen
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
- Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
6
|
O'Reilly MA. Exploiting the mechanical effects of ultrasound for noninvasive therapy. Science 2024; 385:eadp7206. [PMID: 39265013 DOI: 10.1126/science.adp7206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Accepted: 08/07/2024] [Indexed: 09/14/2024]
Abstract
Focused ultrasound is a platform technology capable of eliciting a wide range of biological responses with high spatial precision deep within the body. Although focused ultrasound is already in clinical use for focal thermal ablation of tissue, there has been a recent growth in development and translation of ultrasound-mediated nonthermal therapies. These approaches exploit the physical forces of ultrasound to produce a range of biological responses dependent on exposure conditions. This review discusses recent advances in four application areas that have seen particular growth and have immense clinical potential: brain drug delivery, neuromodulation, focal tissue destruction, and endogenous immune system activation. Owing to the maturation of transcranial ultrasound technology, the brain is a major target organ; however, clinical indications outside the brain are also discussed.
Collapse
Affiliation(s)
- Meaghan A O'Reilly
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON, Canada
- Department of Medical Biophysics, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
7
|
Kadowaki M, Sugiyama K, Nozaki T, Yamasaki T, Namba H, Shimizu M, Kurozumi K. Scalp Nerve Block Alleviates Headaches Associated With Sonication During Transcranial Magnetic Resonance-Guided Focused Ultrasound. Neurosurgery 2024; 95:447-455. [PMID: 38687082 DOI: 10.1227/neu.0000000000002962] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Accepted: 03/01/2024] [Indexed: 05/02/2024] Open
Abstract
BACKGROUND AND OBJECTIVES In magnetic resonance-guided focused ultrasound (MRgFUS) procedures, headache is a frequent symptom and cause of treatment discontinuation. Herein, we assessed the efficacy of scalp nerve block (SNB) for alleviating headache during MRgFUS procedures. METHODS The effect of SNB on intraprocedural headache was examined by retrospectively comparing 2 patient cohorts at a single institution. During the study period from April 2020 to February 2022, an SNB protocol for all patients with a skull density ratio ≤0.55 was instituted on October 6, 2021. The number of patients with a skull density ratio ≤0.55 was 34 before the protocol and 36 afterward. Headache intensity was evaluated using a numerical rating scale (NRS) after each sonication. To evaluate the effect of SNB on headache intensity, multiple regression analysis was performed per patient and per sonication. In the per-patient analysis, the effect of SNB was evaluated using the maximum NRS, mean NRS, and NRS at the first ultrasound exposure that reached 52.5°C. In the per-sonication analysis, the effect of SNB was evaluated not only for the entire sonication but also for sonications classified into ≤9999 J, 10 000 to 29 999 J, and ≥30 000 J energy doses. RESULTS With SNB, headache alleviation was observed in the NRS after the first sonication that reached 52.5°C in each patient (β = -2.40, 95% CI -4.05 to -0.758, P = .00499), in the NRS when all sonications were evaluated (β = -0.647, 95% CI -1.19 to -0.106, P = .0201), and in the NRS when all sonications were classified into 10 000 to 29 999 J (β = -1.83, 95% CI -3.17 to -0.485, P = .00889). CONCLUSION SNB significantly reduced headache intensity during MRgFUS, especially that caused by sonication with a moderate-energy dose. These findings suggest that scalp nerves play a role in headache mechanisms during MRgFUS.
Collapse
Affiliation(s)
- Makoto Kadowaki
- Department of Neurosurgery, Hamamatsu University School of Medicine, Hamamatsu , Shizuoka , Japan
| | - Kenji Sugiyama
- Department of Neurosurgery, Toyoda Eisei Hospital, Iwata , Shizuoka , Japan
| | - Takao Nozaki
- Department of Neurosurgery, Hamamatsu University School of Medicine, Hamamatsu , Shizuoka , Japan
| | - Tomohiro Yamasaki
- Department of Neurosurgery, Hamamatsu University School of Medicine, Hamamatsu , Shizuoka , Japan
| | - Hiroki Namba
- Department of Neurosurgery, JA Shizuoka Kohseiren Enshu Hospital, Hamamatsu , Shizuoka , Japan
| | - Mikihiro Shimizu
- Center for Clinical Research, Hamamatsu University Hospital, Hamamatsu , Shizuoka , Japan
| | - Kazuhiko Kurozumi
- Department of Neurosurgery, Hamamatsu University School of Medicine, Hamamatsu , Shizuoka , Japan
| |
Collapse
|
8
|
Pellow C, Pichardo S, Pike GB. A systematic review of preclinical and clinical transcranial ultrasound neuromodulation and opportunities for functional connectomics. Brain Stimul 2024; 17:734-751. [PMID: 38880207 DOI: 10.1016/j.brs.2024.06.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Revised: 05/21/2024] [Accepted: 06/05/2024] [Indexed: 06/18/2024] Open
Abstract
BACKGROUND Low-intensity transcranial ultrasound has surged forward as a non-invasive and disruptive tool for neuromodulation with applications in basic neuroscience research and the treatment of neurological and psychiatric conditions. OBJECTIVE To provide a comprehensive overview and update of preclinical and clinical transcranial low intensity ultrasound for neuromodulation and emphasize the emerging role of functional brain mapping to guide, better understand, and predict responses. METHODS A systematic review was conducted by searching the Web of Science and Scopus databases for studies on transcranial ultrasound neuromodulation, both in humans and animals. RESULTS 187 relevant studies were identified and reviewed, including 116 preclinical and 71 clinical reports with subjects belonging to diverse cohorts. Milestones of ultrasound neuromodulation are described within an overview of the broader landscape. General neural readouts and outcome measures are discussed, potential confounds are noted, and the emerging use of functional magnetic resonance imaging is highlighted. CONCLUSION Ultrasound neuromodulation has emerged as a powerful tool to study and treat a range of conditions and its combination with various neural readouts has significantly advanced this platform. In particular, the use of functional magnetic resonance imaging has yielded exciting inferences into ultrasound neuromodulation and has the potential to advance our understanding of brain function, neuromodulatory mechanisms, and ultimately clinical outcomes. It is anticipated that these preclinical and clinical trials are the first of many; that transcranial low intensity focused ultrasound, particularly in combination with functional magnetic resonance imaging, has the potential to enhance treatment for a spectrum of neurological conditions.
Collapse
Affiliation(s)
- Carly Pellow
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, T2N 1N4, Canada; Hotchkiss Brain Institute, University of Calgary, Alberta, T2N 4N1, Canada.
| | - Samuel Pichardo
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, T2N 1N4, Canada; Hotchkiss Brain Institute, University of Calgary, Alberta, T2N 4N1, Canada; Department of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Alberta, T2N 1N4, Canada
| | - G Bruce Pike
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, T2N 1N4, Canada; Hotchkiss Brain Institute, University of Calgary, Alberta, T2N 4N1, Canada; Department of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Alberta, T2N 1N4, Canada
| |
Collapse
|
9
|
Xu R, Bestmann S, Treeby BE, Martin E. Strategies and safety simulations for ultrasonic cervical spinal cord neuromodulation. Phys Med Biol 2024; 69:125011. [PMID: 38788727 DOI: 10.1088/1361-6560/ad506f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Accepted: 05/24/2024] [Indexed: 05/26/2024]
Abstract
Objective. Focused ultrasound spinal cord neuromodulation has been demonstrated in small animals. However, most of the tested neuromodulatory exposures are similar in intensity and exposure duration to the reported small animal threshold for possible spinal cord damage. All efforts must be made to minimize the risk and assure the safety of potential human studies, while maximizing potential treatment efficacy. This requires an understanding of ultrasound propagation and heat deposition within the human spine.Approach. Combined acoustic and thermal modelling was used to assess the pressure and heat distributions produced by a 500 kHz source focused to the C5/C6 level via two approaches (a) the posterior acoustic window between vertebral posterior arches, and (b) the lateral intervertebral foramen from which the C6 spinal nerve exits. Pulse trains of fifty 0.1 s pulses (pulse repetition frequency: 0.33 Hz, free-field spatial peak pulse-averaged intensity: 10 W cm-2) were simulated for four subjects and for ±10 mm translational and ±10∘rotational source positioning errors.Main results.Target pressures ranged between 20%-70% of free-field spatial peak pressures with the posterior approach, and 20%-100% with the lateral approach. When the posterior source was optimally positioned, peak spine heating values were below 1 ∘C, but source mispositioning resulted in bone heating up to 4 ∘C. Heating with the lateral approach did not exceed 2 ∘C within the mispositioning range. There were substantial inter-subject differences in target pressures and peak heating values. Target pressure varied three to four-fold between subjects, depending on approach, while peak heating varied approximately two-fold between subjects. This results in a nearly ten-fold range between subjects in the target pressure achieved per degree of maximum heating.Significance. This study highlights the utility of trans-spine ultrasound simulation software and need for precise source-anatomy positioning to assure the subject-specific safety and efficacy of focused ultrasound spinal cord therapies.
Collapse
Affiliation(s)
- Rui Xu
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, United Kingdom
| | - Sven Bestmann
- Department of Clinical and Movement Neuroscience, University College London, London, United Kingdom
| | - Bradley E Treeby
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| | - Eleanor Martin
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, United Kingdom
| |
Collapse
|
10
|
Deng L, Lea-Banks H, Jones RM, O’Reilly MA, Hynynen K. Three-dimensional super resolution ultrasound imaging with a multi-frequency hemispherical phased array. Med Phys 2023; 50:7478-7497. [PMID: 37702919 PMCID: PMC10872837 DOI: 10.1002/mp.16733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Accepted: 08/27/2023] [Indexed: 09/14/2023] Open
Abstract
BACKGROUND High resolution imaging of the microvasculature plays an important role in both diagnostic and therapeutic applications in the brain. However, ultrasound pulse-echo sonography imaging the brain vasculatures has been limited to narrow acoustic windows and low frequencies due to the distortion of the skull bone, which sacrifices axial resolution since it is pulse length dependent. PURPOSE To overcome the detect limit, a large aperture 256-module sparse hemispherical transmit/receive array was used to visualize the acoustic emissions of ultrasound-vaporized lipid-coated decafluorobutane nanodroplets flowing through tube phantoms and within rabbit cerebral vasculature in vivo via passive acoustic mapping and super resolution techniques. METHODS Nanodroplets were vaporized with 55 kHz burst-mode ultrasound (burst length = 145 μs, burst repetition frequency = 9-45 Hz, peak negative acoustic pressure = 0.10-0.22 MPa), which propagates through overlying tissues well without suffering from severe distortions. The resulting emissions were received at a higher frequency (612 or 1224 kHz subarray) to improve the resulting spatial resolution during passive beamforming. Normal resolution three-dimensional images were formed using a delay, sum, and integrate beamforming algorithm, and super-resolved images were extracted via Gaussian fitting of the estimated point-spread-function to the normal resolution data. RESULTS With super resolution techniques, the mean lateral (axial) full-width-at-half-maximum image intensity was 16 ± 3 (32 ± 6) μm, and 7 ± 1 (15 ± 2) μm corresponding to ∼1/67 of the normal resolution at 612 and 1224 kHz, respectively. The mean positional uncertainties were ∼1/350 (lateral) and ∼1/180 (axial) of the receive wavelength in water. In addition, a temporal correlation between nanodroplet vaporization and the transmit waveform shape was observed, which may provide the opportunity to enhance the signal-to-noise ratio in future studies. CONCLUSIONS Here, we demonstrate the feasibility of vaporizing nanodroplets via low frequency ultrasound and simultaneously performing spatial mapping via passive beamforming at higher frequencies to improve the resulting spatial resolution of super resolution imaging techniques. This method may enable complete four-dimensional vascular mapping in organs where a hemispherical array could be positioned to surround the target, such as the brain, breast, or testicles.
Collapse
Affiliation(s)
- Lulu Deng
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, M4N 3M5, Canada
| | - Harriet Lea-Banks
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, M4N 3M5, Canada
| | - Ryan M. Jones
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, M4N 3M5, Canada
| | - Meaghan A. O’Reilly
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, M4N 3M5, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, M5G 1L7, Canada
| | - Kullervo Hynynen
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, M4N 3M5, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, M5G 1L7, Canada
- Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario, M5S 3E2, Canada
| |
Collapse
|
11
|
Sharahi HJ, Acconcia CN, Li M, Martel A, Hynynen K. A Convolutional Neural Network for Beamforming and Image Reconstruction in Passive Cavitation Imaging. SENSORS (BASEL, SWITZERLAND) 2023; 23:8760. [PMID: 37960460 PMCID: PMC10650508 DOI: 10.3390/s23218760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 10/18/2023] [Accepted: 10/20/2023] [Indexed: 11/15/2023]
Abstract
Convolutional neural networks (CNNs), initially developed for image processing applications, have recently received significant attention within the field of medical ultrasound imaging. In this study, passive cavitation imaging/mapping (PCI/PAM), which is used to map cavitation sources based on the correlation of signals across an array of receivers, is evaluated. Traditional reconstruction techniques in PCI, such as delay-and-sum, yield high spatial resolution at the cost of a substantial computational time. This results from the resource-intensive process of determining sensor weights for individual pixels in these methodologies. Consequently, the use of conventional algorithms for image reconstruction does not meet the speed requirements that are essential for real-time monitoring. Here, we show that a three-dimensional (3D) convolutional network can learn the image reconstruction algorithm for a 16×16 element matrix probe with a receive frequency ranging from 256 kHz up to 1.0 MHz. The network was trained and evaluated using simulated data representing point sources, resulting in the successful reconstruction of volumetric images with high sensitivity, especially for single isolated sources (100% in the test set). As the number of simultaneous sources increased, the network's ability to detect weaker intensity sources diminished, although it always correctly identified the main lobe. Notably, however, network inference was remarkably fast, completing the task in approximately 178 s for a dataset comprising 650 frames of 413 volume images with signal duration of 20μs. This processing speed is roughly thirty times faster than a parallelized implementation of the traditional time exposure acoustics algorithm on the same GPU device. This would open a new door for PCI application in the real-time monitoring of ultrasound ablation.
Collapse
Affiliation(s)
- Hossein J. Sharahi
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada (A.M.)
| | - Christopher N. Acconcia
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada (A.M.)
| | - Matthew Li
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada (A.M.)
| | - Anne Martel
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada (A.M.)
- Department of Medical Biophysics, University of Toronto, Toronto, ON M5G 1L7, Canada
| | - Kullervo Hynynen
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada (A.M.)
- Department of Medical Biophysics, University of Toronto, Toronto, ON M5G 1L7, Canada
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON M5S 3G9, Canada
| |
Collapse
|
12
|
Pellow C, Li S, Delgado S, Pike GB, Curiel L, Pichardo S. Biaxial ultrasound driving technique for small animal blood-brain barrier opening. Phys Med Biol 2023; 68:195006. [PMID: 37607563 DOI: 10.1088/1361-6560/acf2e3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Accepted: 08/22/2023] [Indexed: 08/24/2023]
Abstract
Biaxial driving can more efficiently convert electrical power to forward acoustic power in piezoelectric materials, and the interaction between the orthogonal electric fields can produce a combination of extensional and shear deformations as a function of the phase difference between them to allow dynamic steering of the beam with a single-element. In this study, we demonstrate for the first time the application of a single-element biaxially driven ring transducerin vivofor blood-brain barrier opening in mice, and compare it to that achieved with a conventional single-element highly focused (F# = 0.7) spherical transducer operating at a similar frequency. Transcranial focused ultrasound (0.45 MPa, 10 ms pulse length, 1 Hz repetition frequency, 30 s duration) was applied bilaterally to mice with a 40μl/kg bolus of DefinityTMmicrobubbles, employing either a single-element biaxial ring (1.482 MHz, 10 mm inner diameter, 13.75 mm outer diameter) or spherical (1.5 MHz, 35 mm diameter, F# = 0.7; RK50, FUS Instruments) transducer on each side. Follow-up MRI scans (T1 pre- and post- 0.2 mmol/kg Gd injection, T2) were acquired to assess blood-brain barrier opening volume and potential damage. Compared to blood-brain barrier opening achieved with a conventional single-element spherical focused transducer, the opening volume achieved with a single-element biaxial ring transducer was 35% smaller (p= 0.002) with a device of a ring diameter of 40% the aperture size. Axial refocusing was further demonstrated with the single-element biaxial ring transducer, yielding a 1.63 mm deeper, five-fold larger opening volume (p= 0.048) relative to its small-focus mode. The biaxial ring transducer achieved a more localized opening compared to the spherical focused transducer under the same parameters, and further enabled dynamic axial refocusing with a single-element transducer with a smaller fabrication footprint.
Collapse
Affiliation(s)
- Carly Pellow
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, Canada
- Hotchkiss Brain Institute, University of Calgary, Alberta, Canada
| | - Siyun Li
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, Canada
| | - Sagid Delgado
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, Canada
| | - G Bruce Pike
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, Canada
- Hotchkiss Brain Institute, University of Calgary, Alberta, Canada
- Department of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Alberta, Canada
| | - Laura Curiel
- Hotchkiss Brain Institute, University of Calgary, Alberta, Canada
- Department of Biomedical Engineering, Schulich School of Engineering, University of Calgary, Alberta, Canada
| | - Samuel Pichardo
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, Canada
- Hotchkiss Brain Institute, University of Calgary, Alberta, Canada
- Department of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Alberta, Canada
| |
Collapse
|
13
|
Ferreira Felloni Borges Y, Cheyuo C, Lozano AM, Fasano A. Essential Tremor - Deep Brain Stimulation vs. Focused Ultrasound. Expert Rev Neurother 2023; 23:603-619. [PMID: 37288812 DOI: 10.1080/14737175.2023.2221789] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Accepted: 06/01/2023] [Indexed: 06/09/2023]
Abstract
INTRODUCTION Essential Tremor (ET) is one of the most common tremor syndromes typically presented as action tremor, affecting mainly the upper limbs. In at least 30-50% of patients, tremor interferes with quality of life, does not respond to first-line therapies and/or intolerable adverse effects may occur. Therefore, surgery may be considered. AREAS COVERED In this review, the authors discuss and compare unilateral ventral intermedius nucleus deep brain stimulation (VIM DBS) and bilateral DBS with Magnetic Resonance-guided Focused Ultrasound (MRgFUS) thalamotomy, which comprises focused acoustic energy generating ablation under real-time MRI guidance. Discussion includes their impact on tremor reduction and their potential complications. Finally, the authors provide their expert opinion. EXPERT OPINION DBS is adjustable, potentially reversible and allows bilateral treatments; however, it is invasive requires hardware implantation, and has higher surgical risks. Instead, MRgFUS is less invasive, less expensive, and requires no hardware maintenance. Beyond these technical differences, the decision should also involve the patient, family, and caregivers.
Collapse
Affiliation(s)
- Yuri Ferreira Felloni Borges
- Edmond J. Safra Program in Parkinson's Disease, Division of Neurology, Morton and Gloria Shulman Movement Disorders Clinic, Toronto Western Hospital, UHN, University of Toronto, Toronto, ON, Canada
| | - Cletus Cheyuo
- Division of Neurosurgery, Toronto Western Hospital, University Health Network, Toronto, ON, Canada
| | - Andres M Lozano
- Division of Neurosurgery, Toronto Western Hospital, University Health Network, Toronto, ON, Canada
- Krembil Brain Institute, Toronto, ON, Canada
| | - Alfonso Fasano
- Edmond J. Safra Program in Parkinson's Disease, Division of Neurology, Morton and Gloria Shulman Movement Disorders Clinic, Toronto Western Hospital, UHN, University of Toronto, Toronto, ON, Canada
- Krembil Brain Institute, Toronto, ON, Canada
- Center for Advancing Neurotechnological Innovation to Application (CRANIA), Toronto, ON, Canada
- Department of Parkinson's Disease & Movement Disorders Rehabilitation, Moriggia-Pelascini Hospital, Gravedona Ed Uniti, Como, Italy
| |
Collapse
|
14
|
Xu K, Yang Y, Hu Z, Yue Y, Gong Y, Cui J, Culver JP, Bruchas MR, Chen H. TRPV1-mediated sonogenetic neuromodulation of motor cortex in freely moving mice. J Neural Eng 2023; 20:016055. [PMID: 36780694 PMCID: PMC9969813 DOI: 10.1088/1741-2552/acbba0] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 01/03/2023] [Accepted: 02/13/2023] [Indexed: 02/15/2023]
Abstract
Background.Noninvasive and cell-type-specific neuromodulation tools are critically needed for probing intact brain function. Sonogenetics for noninvasive activation of neurons engineered to express thermosensitive transient receptor potential vanilloid 1 (TRPV1) by transcranial focused ultrasound (FUS) was recently developed to address this need. However, using TRPV1-mediated sonogenetics to evoke behavior by targeting the cortex is challenged by its proximity to the skull due to high skull absorption of ultrasound and increased risks of thermal-induced tissue damage.Objective.This study evaluated the feasibility and safety of TRPV1-mediated sonogenetics in targeting the motor cortex to modulate the locomotor behavior of freely moving mice.Approach.Adeno-associated viral vectors was delivered to the mouse motor cortex via intracranial injection to express TRPV1 in excitatory neurons. A wearable FUS device was installed on the mouse head after a month to control neuronal activity by activating virally expressed TRPV1 through FUS sonication at different acoustic pressures. Immunohistochemistry staining ofex vivobrain slices was performed to verify neuron activation and evaluate safety.Results.TRPV1-mediated sonogenetic stimulation at 0.7 MPa successfully evoked rotational behavior in the direction contralateral to the stimulation site, activated cortical neurons as indicated by the upregulation of c-Fos, and did not induce significant changes in inflammatory or apoptotic markers (GFAP, Iba1, and Caspase-3). Sonogenetic stimulation of TRPV1 mice at a higher acoustic pressure, 1.1 MPa, induced significant changes in motor behavior and upregulation of c-Fos compared with FUS sonication of naïve mice at 1.1 MPa. However, signs of damage at the meninges were observed at 1.1 MPa.Significance.TRPV1-mediated sonogenetics can achieve effective and safe neuromodulation at the cortex with carefully selected FUS parameters. These findings expand the application of this technique to include superficial brain targets.
Collapse
Affiliation(s)
- Kevin Xu
- Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, MO 63130, United States of America
| | - Yaoheng Yang
- Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, MO 63130, United States of America
| | - Zhongtao Hu
- Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, MO 63130, United States of America
| | - Yimei Yue
- Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, MO 63130, United States of America
| | - Yan Gong
- Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, MO 63130, United States of America
| | - Jianmin Cui
- Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, MO 63130, United States of America
| | - Joseph P Culver
- Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, MO 63130, United States of America
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, Saint Louis, MO 63110, United States of America
- Department of Physics, Washington University in St. Louis, Saint Louis, MO 63110, United States of America
| | - Michael R Bruchas
- Department of Anesthesiology and Pain Medicine, Center of Neurobiology of Addiction, Pain, and Emotion, University of Washington, Seattle, WA 98195, United States of America
| | - Hong Chen
- Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, MO 63130, United States of America
- Department of Radiation Oncology, Washington University School of Medicine, Saint Louis, MO 63108, United States of America
| |
Collapse
|
15
|
Duclos S, Golin A, Fox A, Chaudhary N, Camelo-Piragua S, Pandey A, Xu Z. Transcranial histotripsy parameter study in primary and metastatic murine brain tumor models. Int J Hyperthermia 2023; 40:2237218. [PMID: 37495214 PMCID: PMC10410615 DOI: 10.1080/02656736.2023.2237218] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 07/07/2023] [Accepted: 07/11/2023] [Indexed: 07/28/2023] Open
Abstract
OBJECTIVE This study investigated the effect of various histotripsy dosages on tumor cell kill and associated bleeding in two murine brain tumor models (glioma [Gl261] and lung metastasis [LL/2-Luc2]). METHODS AND MATERIALS GL261 or LL/2-Luc2 cells were cultured and implanted into the brains of C57BL/6 mice. Histotripsy (1-cycle pulses, 5 Hz PRF, 30 MPa-P) was performed using a 1 MHz transducer for five different dosages for each cell line: 5, 20 or 200 pulses per location (PPL) at a single treatment point, or 5 or 10-20 PPL at multiple treatment points. MRI, bioluminescence imaging and histology were used to assess tumor ablation and treatment effects within 4-6 h post-treatment. RESULTS All treatment groups resulted in a reduction of BLI intensity for the LL/2-Luc2 tumors, with significant signal reductions for the multi-point groups. The average pre-/post-treatment BLI flux (photons/s, ×108) for the different treatment groups were: 4.39/2.19 (5 PPL single-point), 5.49/1.80 (20 PPL single-point), 3.86/1.73 (200 PPL single-point), 2.44/1.11 (5 PPL multi-point) and 5.85/0.80 (10 PPL multi-point). MRI and H&E staining showed increased tumor damage and hemorrhagic effects with increasing histotripsy dose for both GL261 and LL/2-Luc2 tumors, but the increase in tumor damage was diminished beyond 10-20 PPL for single-point treatments and outweighed by increased hemorrhage. In general, hemorrhage was confined to be within 1 mm of the treatment boundary for all groups. CONCLUSIONS Our results suggest that a lower number of histotripsy pulses at fewer focal locations can achieve substantial tumor kill while minimizing hemorrhage.
Collapse
Affiliation(s)
- Sarah Duclos
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Andrew Golin
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Adam Fox
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
- Department of Neurosurgery, University of Michigan, Ann Arbor, MI, USA
| | - Neeraj Chaudhary
- Department of Neurosurgery, University of Michigan, Ann Arbor, MI, USA
- Department of Radiology, University of Michigan, Ann Arbor, MI, USA
| | | | - Aditya Pandey
- Department of Neurosurgery, University of Michigan, Ann Arbor, MI, USA
| | - Zhen Xu
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
16
|
Andrés D, Jiménez N, Benlloch JM, Camarena F. Numerical Study of Acoustic Holograms for Deep-Brain Targeting through the Temporal Bone Window. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:872-886. [PMID: 35221196 DOI: 10.1016/j.ultrasmedbio.2022.01.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 01/14/2022] [Accepted: 01/16/2022] [Indexed: 06/14/2023]
Abstract
Acoustic holograms can encode complex wavefronts to compensate the aberrations of a therapeutical ultrasound beam propagating through heterogeneous tissues such as the skull, and simultaneously, they can generate diffraction-limited acoustic images, that is, arbitrary shaped focal spots. In this work, we numerically study the performance of acoustic holograms focusing at the thalamic nuclei when the source is located at the temporal bone window. The temporal window is the thinnest area of the lateral skull and it is mainly hairless, so it is a desirable area through which to transmit ultrasonic waves to the deep brain. However, in targeting from this area the bilateral thalamic nuclei are not aligned with the elongated focal spots of conventional focused transducers, and in addition, skull aberrations can distort the focal spot. We found that by using patient-specific holographic lenses coupled to a single-element 650-kHz-frequency 65-mm-aperture source, the focal spot can be sharply adapted to the thalamic nuclei in a bilateral way while skull aberrations are mitigated. Furthermore, the performance of these holograms was studied under misalignment errors between the source and the skull, concluding that for misalignments up to 5°, acoustic images are correctly restored. This work paves the way to designing clinical applications of transcranial ultrasound such as blood-brain barrier opening for drug delivery or deep-brain neuromodulation using this low-cost and personalized technology, presenting desirable aspects for long-term treatments because the patient's head does not need to be shaved completely and skull heating is low.
Collapse
Affiliation(s)
- Diana Andrés
- Instituto de Instrumentación para Imagen Molecular (i3M), Universitat Politècnica de València, Consejo Superior de Investigaciones Científicas (CSIC), València, Spain
| | - Noé Jiménez
- Instituto de Instrumentación para Imagen Molecular (i3M), Universitat Politècnica de València, Consejo Superior de Investigaciones Científicas (CSIC), València, Spain.
| | - José M Benlloch
- Instituto de Instrumentación para Imagen Molecular (i3M), Universitat Politècnica de València, Consejo Superior de Investigaciones Científicas (CSIC), València, Spain
| | - Francisco Camarena
- Instituto de Instrumentación para Imagen Molecular (i3M), Universitat Politècnica de València, Consejo Superior de Investigaciones Científicas (CSIC), València, Spain
| |
Collapse
|
17
|
Smith CS, O'Driscoll C, Ebbini ES. Spatio-Spectral Ultrasound Characterization of Reflection and Transmission Through Bone With Temperature Dependence. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:1727-1737. [PMID: 35349438 PMCID: PMC9050954 DOI: 10.1109/tuffc.2022.3163225] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Transcranial focused ultrasound (tFUS) is a promising approach for the treatment of neurological disorders. It has proven useful in several clinical applications, with promising outcomes reported in the recent literature. Furthermore, it is currently being investigated in a range of neuromodulation (NM) and ablative applications, including epilepsy. In this application, tFUS access through the temporal window is the key to optimizing the treatment safety and efficacy. Traditional approaches have utilized transducers with low operating frequencies for tFUS applications. Modern array transducers and driving systems allow for more intelligent use of the temporal window by exploiting the spatio-spectral transmission bandwidth to a specified target or targets within the brain. To demonstrate the feasibility of this approach, we have investigated the ultrasound reflection and transmission characteristics for different access points within the temporal window of human skull samples ex vivo. Different transmit-receive (Rx) configurations are used for characterization of the spatio-spectral variability in reflection and transmission through the temporal window. In this article, we show results from a dual-piston transducer set up in the frequency range of 2-7 MHz. Broadband pulses as well as synthesized orthogonal frequency division multiplexed (OFDM) waveforms were used. The latter was used to improve the magnitude and phase measurements in 100-kHz subbands within the 2-7 MHz spectral window. A temperature-controlled water bath was used to characterize the change in reflection and transmission characteristics with temperature in the 25°C-43°C range. The measured values of the complex reflection and transmission coefficients exhibited significant variations with space, frequency, and temperature. On the other hand, the measured transmission phase varied more with location and frequency, with smaller sensitivity to temperature. A measurement-based hybrid angular spectrum (HAS) simulation through the human temporal bone was used to demonstrate the dependence of focusing gain on the skull profile and spatial distribution of change of speed of sound (SOS) at different skull temperatures.
Collapse
|
18
|
Davidson B, Hamani C, Huang Y, Jones RM, Meng Y, Giacobbe P, Lipsman N. Magnetic Resonance-Guided Focused Ultrasound Capsulotomy for Treatment-Resistant Psychiatric Disorders. Oper Neurosurg (Hagerstown) 2021; 19:741-749. [PMID: 32735671 DOI: 10.1093/ons/opaa240] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Accepted: 05/27/2020] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND Psychiatric surgery is an important domain of functional neurosurgery and involves deep brain stimulation (DBS) or lesional procedures performed for treatment-resistant psychiatric illness. It has recently become possible to use magnetic-guided focused ultrasound (MRgFUS) to perform bilateral capsulotomy, a lesional technique commonly carried out with surgical radiofrequency ablation or stereotactic radiosurgery. MRgFUS offers several advantages, including improved safety and real-time imaging of the lesions. OBJECTIVE To describe the clinical and technical aspects of performing bilateral MRgFUS capsulotomy in patients with severe refractory depression and obsessive-compulsive disorder. METHODS We describe the clinical and technical considerations of performing MRgFUS capsulotomy. Topics discussed include patient selection, headframe application, targeting, sonication strategies, and follow-up procedures. RESULTS MRgFUS capsulotomy was performed in 16 patients without serious clinical or radiographic adverse events. CONCLUSION MRgFUS allows for a safe, less invasive technique for performing a well-studied psychiatric surgery procedure-the anterior capsulotomy.
Collapse
Affiliation(s)
- Benjamin Davidson
- Division of Neurosurgery, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Canada.,Harquail Centre for Neuromodulation, Hurvitz Brain Sciences Program, Sunnybrook Research Institute, Toronto, Canada.,Sunnybrook Research Institute, Toronto Canada
| | - Clement Hamani
- Division of Neurosurgery, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Canada.,Harquail Centre for Neuromodulation, Hurvitz Brain Sciences Program, Sunnybrook Research Institute, Toronto, Canada.,Sunnybrook Research Institute, Toronto Canada
| | - Yuexi Huang
- Sunnybrook Research Institute, Toronto Canada.,Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada
| | - Ryan M Jones
- Sunnybrook Research Institute, Toronto Canada.,Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada
| | - Ying Meng
- Division of Neurosurgery, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Canada.,Harquail Centre for Neuromodulation, Hurvitz Brain Sciences Program, Sunnybrook Research Institute, Toronto, Canada.,Sunnybrook Research Institute, Toronto Canada
| | - Peter Giacobbe
- Harquail Centre for Neuromodulation, Hurvitz Brain Sciences Program, Sunnybrook Research Institute, Toronto, Canada.,Sunnybrook Research Institute, Toronto Canada.,Department of Psychiatry, Sunnybrook Health Sciences Centre, Toronto, Canada
| | - Nir Lipsman
- Division of Neurosurgery, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Canada.,Harquail Centre for Neuromodulation, Hurvitz Brain Sciences Program, Sunnybrook Research Institute, Toronto, Canada.,Sunnybrook Research Institute, Toronto Canada
| |
Collapse
|
19
|
Top CB. A Generalized Split-Step Angular Spectrum Method for Efficient Simulation of Wave Propagation in Heterogeneous Media. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2687-2696. [PMID: 33891551 DOI: 10.1109/tuffc.2021.3075367] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Angular spectrum (AS) methods enable efficient calculation of wave propagation from one plane to another inside homogeneous media. For wave propagation in heterogeneous media such as biological tissues, AS methods cannot be applied directly. Split-stepping techniques decompose the heterogeneous domain into homogeneous and perturbation parts, and provide a solution for forward wave propagation by propagating the incident wave in both frequency-space and frequency-wavenumber domains. Recently, a split-step hybrid angular spectrum (HAS) method was proposed for plane wave propagation of focused ultrasound beams. In this study, we extend these methods to enable simulation of acoustic pressure field for an arbitrary source distribution, by decomposing the source and reflection spectra into orthogonal propagation direction components, propagating each component separately, and summing all components to get the total field. We show that our method can efficiently simulate the pressure field of arbitrary sources in heterogeneous media. The accuracy of the method was analyzed comparing the resultant pressure field with pseudospectral time domain (PSTD) solution for breast tomography and hemispherical transcranial-focused ultrasound simulation models. Eighty times acceleration was achieved for a 3-D breast simulation model compared to PSTD solution with 0.005 normalized root mean-squared difference (NRMSD) between two solutions. For the hemispherical phased array, aberrations due to skull were accurately calculated in a single simulation run as evidenced by the resultant-focused ultrasound beam simulations, which had 0.001 NRMSD with 40 times acceleration factor compared to the PSTD method.
Collapse
|
20
|
Davidson B, Mithani K, Huang Y, Jones RM, Goubran M, Meng Y, Snell J, Hynynen K, Hamani C, Lipsman N. Technical and radiographic considerations for magnetic resonance imaging-guided focused ultrasound capsulotomy. J Neurosurg 2021; 135:291-299. [PMID: 32977311 DOI: 10.3171/2020.6.jns201302] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 06/04/2020] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Magnetic resonance imaging-guided focused ultrasound (MRgFUS) is an emerging treatment modality that enables incisionless ablative neurosurgical procedures. Bilateral MRgFUS capsulotomy has recently been demonstrated to be safe and effective in treating obsessive-compulsive disorder (OCD) and major depressive disorder (MDD). Preliminary evidence has suggested that bilateral MRgFUS capsulotomy can present increased difficulties in reaching lesional temperatures as compared to unilateral thalamotomy. The authors of this article aimed to study the parameters associated with successful MRgFUS capsulotomy lesioning and to present longitudinal radiographic findings following MRgFUS capsulotomy. METHODS Using data from 22 attempted MRgFUS capsulotomy treatments, the authors investigated the relationship between various sonication parameters and the maximal temperature achieved at the intracranial target. Lesion volume and morphology were analyzed longitudinally using structural and diffusion tensor imaging. A retreatment procedure was attempted in one patient, and their postoperative imaging is presented. RESULTS Skull density ratio (SDR), skull thickness, and angle of incidence were significantly correlated with the maximal temperature achieved. MRgFUS capsulotomy lesions appeared similar to those following MRgFUS thalamotomy, with three concentric zones observed on MRI. Lesion volumes regressed substantially over time following MRgFUS. Fractional anisotropy analysis revealed a disruption in white matter integrity, followed by a gradual return to near-baseline levels concurrent with lesion regression. In the patient who underwent retreatment, successful bilateral lesioning was achieved, and there were no adverse clinical or radiographic events. CONCLUSIONS With the current iteration of MRgFUS technology, skull-related parameters such as SDR, skull thickness, and angle of incidence should be considered when selecting patients suitable for MRgFUS capsulotomy. Lesions appear to follow morphological patterns similar to what is seen following MRgFUS thalamotomy. Retreatment appears to be safe, although additional cases will be necessary to further evaluate the associated safety profile.
Collapse
Affiliation(s)
- Benjamin Davidson
- 1Division of Neurosurgery, Sunnybrook Health Sciences Centre
- 2Harquail Centre for Neuromodulation and Hurvitz Brain Sciences Program
- 3Sunnybrook Research Institute
| | - Karim Mithani
- 1Division of Neurosurgery, Sunnybrook Health Sciences Centre
- 2Harquail Centre for Neuromodulation and Hurvitz Brain Sciences Program
- 3Sunnybrook Research Institute
| | - Yuexi Huang
- 3Sunnybrook Research Institute
- 4Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Ryan M Jones
- 3Sunnybrook Research Institute
- 4Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Maged Goubran
- 2Harquail Centre for Neuromodulation and Hurvitz Brain Sciences Program
- 3Sunnybrook Research Institute
- 4Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
- 7Department of Medical Biophysics, University of Toronto; and
| | - Ying Meng
- 1Division of Neurosurgery, Sunnybrook Health Sciences Centre
- 2Harquail Centre for Neuromodulation and Hurvitz Brain Sciences Program
- 3Sunnybrook Research Institute
| | - John Snell
- 5The Focused Ultrasound Foundation, Charlottesville
- 6Department of Neurosurgery, University of Virginia, Charlottesville, Virginia
| | - Kullervo Hynynen
- 2Harquail Centre for Neuromodulation and Hurvitz Brain Sciences Program
- 3Sunnybrook Research Institute
- 4Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
- 7Department of Medical Biophysics, University of Toronto; and
- 8Institute of Biomaterials and Biomedical Engineering, Toronto, Ontario, Canada
| | - Clement Hamani
- 1Division of Neurosurgery, Sunnybrook Health Sciences Centre
- 2Harquail Centre for Neuromodulation and Hurvitz Brain Sciences Program
- 3Sunnybrook Research Institute
| | - Nir Lipsman
- 1Division of Neurosurgery, Sunnybrook Health Sciences Centre
- 2Harquail Centre for Neuromodulation and Hurvitz Brain Sciences Program
- 3Sunnybrook Research Institute
| |
Collapse
|
21
|
Pooja NA, Pahuja SK, Veer K. Significance of MRI Guided Focused Ultrasound Thalamotomy for Parkinson's Disease: A Review. Curr Med Imaging 2021; 17:714-719. [PMID: 33357197 DOI: 10.2174/1573405616666201223142505] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 09/23/2020] [Accepted: 10/14/2020] [Indexed: 11/22/2022]
Abstract
BACKGROUND Magnetic-Resonance guided Focused Ultrasound (FUS) thalamotomy is a new and less invasive surgical technique for treating Parkinson's disease (PD). During therapy, the required part of the cerebral (as STN, Internal Globus Pallidus, and Ventral Intermediate Nucleus) is ablated with less possibility of infection and brain hemorrhage as it normally happens in invasive procedures. INTRODUCTION New advancement in the technique enables it for transcranial transportation of US. Nowadays, US coupling with MRI confirms the accurate energy transferring and monitoring. So, MRI guided FUS lesioning is discovered for various psychiatric and brain disorders. METHODS A technical overview of non-invasive MRI-FUS thalamotomy to treat various tremors is described here. Research, review articles, and book chapters are extracted from online resources using related search strings from the year 1994-2020. RESULTS MRgFUS is concluded a non-invasive, satisfactory, and safe technique to reduce the tremor. Conlusion: MRgFUS is comparatively a new method that is being explored as a non-invasive cerebral ablation to solve the problems of movement disorder.
Collapse
Affiliation(s)
- N A Pooja
- Department of Instrumentation and Control Engineering, Dr. B. R. Ambedkar National Institute of Technology, Jalandhar, Punjab, India
| | - S K Pahuja
- Department of Instrumentation and Control Engineering, Dr. B. R. Ambedkar National Institute of Technology, Jalandhar, Punjab, India
| | - K Veer
- Department of Instrumentation and Control Engineering, Dr. B. R. Ambedkar National Institute of Technology, Jalandhar, Punjab, India
| |
Collapse
|
22
|
Meng Y, Jones RM, Davidson B, Huang Y, Pople CB, Surendrakumar S, Hamani C, Hynynen K, Lipsman N. Technical Principles and Clinical Workflow of Transcranial MR-Guided Focused Ultrasound. Stereotact Funct Neurosurg 2020; 99:329-342. [PMID: 33302282 DOI: 10.1159/000512111] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Accepted: 09/28/2020] [Indexed: 11/19/2022]
Abstract
Transcranial MR-guided focused ultrasound (MRgFUS) is a rapidly developing technology in neuroscience for manipulating brain structure and function without open surgery. The effectiveness of transcranial MRgFUS for thermoablation is well established, and the technique is actively employed worldwide for movement disorders including essential tremor. A growing number of centers are also investigating the potential of microbubble-mediated focused ultrasound-induced opening of the blood-brain barrier (BBB) for targeted drug delivery to the brain. Here, we provide a technical overview of the principles, clinical workflow, and operator considerations of transcranial MRgFUS procedures for both thermoablation and BBB opening.
Collapse
Affiliation(s)
- Ying Meng
- Sunnybrook Research Institute, University of Toronto, Toronto, Ontario, Canada.,Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada
| | - Ryan M Jones
- Sunnybrook Research Institute, University of Toronto, Toronto, Ontario, Canada
| | - Benjamin Davidson
- Sunnybrook Research Institute, University of Toronto, Toronto, Ontario, Canada.,Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada
| | - Yuexi Huang
- Sunnybrook Research Institute, University of Toronto, Toronto, Ontario, Canada
| | - Christopher B Pople
- Sunnybrook Research Institute, University of Toronto, Toronto, Ontario, Canada
| | | | - Clement Hamani
- Sunnybrook Research Institute, University of Toronto, Toronto, Ontario, Canada.,Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada
| | - Kullervo Hynynen
- Sunnybrook Research Institute, University of Toronto, Toronto, Ontario, Canada.,Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.,Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
| | - Nir Lipsman
- Sunnybrook Research Institute, University of Toronto, Toronto, Ontario, Canada, .,Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada,
| |
Collapse
|
23
|
McDannold N, White PJ, Cosgrove R. Predicting Bone Marrow Damage in the Skull After Clinical Transcranial MRI-Guided Focused Ultrasound With Acoustic and Thermal Simulations. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:3231-3239. [PMID: 32324544 PMCID: PMC7529866 DOI: 10.1109/tmi.2020.2989121] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Transcranial MRI-guided focused ultrasound (TcMRgFUS) thermal ablation is a noninvasive functional neurosurgery technique. Previous reports have shown that damage in the skull bone marrow can occur at high acoustic energies. While this damage is asymptomatic, it would be desirable to avoid it. Here we examined whether acoustic and thermal simulations can predict where the thermal lesions in the marrow occurred. Post-treatment imaging was obtained at 3-15 months after 40 clinical TcMRgFUS procedures, and bone marrow lesions were observed after 16 treatments. The presence of lesions was predicted by the acoustic energy with a threshold of 18.1-21.1 kJ (maximum acoustic energy used) and 97-112 kJ (total acoustic energy applied over the whole treatment). The size of the lesions was not always predicted by the acoustic energy used during treatment alone. In contrast, the locations, sizes, and shapes of the heated regions estimated by the acoustic and thermal simulations were qualitatively similar to those of the lesions. The lesions generally appeared in areas that were predicted to have high temperatures. While more work is needed to validate the temperature estimates in and around the skull, being able to predict the locations and onset for lesions in the bone marrow could allow for better distribution of the acoustic energy over the skull. Understanding skull absorption characteristics of TcMRgFUS could also be useful in optimizing transcranial focusing.
Collapse
|
24
|
Jones RM, Huang Y, Meng Y, Scantlebury N, Schwartz ML, Lipsman N, Hynynen K. Echo-Focusing in Transcranial Focused Ultrasound Thalamotomy for Essential Tremor: A Feasibility Study. Mov Disord 2020; 35:2327-2333. [PMID: 32815611 DOI: 10.1002/mds.28226] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Revised: 06/30/2020] [Accepted: 07/02/2020] [Indexed: 11/06/2022] Open
Abstract
BACKGROUND Transcranial magnetic resonance-guided focused ultrasound (TcMRgFUS) systems currently employ computed tomography (CT)-based aberration corrections, which may provide suboptimal trans-skull focusing. OBJECTIVES The objective of this study was to evaluate a contrast agent microbubble imaging-based transcranial focusing method, echo-focusing (EF), during TcMRgFUS for essential tremor. METHODS A clinical trial of TcMRgFUS thalamotomy using EF for the treatment of essential tremor was conducted (NCT03935581; funded by InSightec [Tirat Carmel, Israel]). Patients (n = 12) were injected with Definity (Lantheus Medical Imaging, North Billerica, MA) microbubbles, and EF was performed using a research feature add-on to a commercial TcMRgFUS system (ExAblate Neuro, InSightec). Subablative thermal sonications carried out using (1) EF and (2) CT-based aberration corrections were compared via magnetic resonance thermometry, and the optimal focusing method for each patient was employed for TcMRgFUS thalamotomy. RESULTS EF aberration corrections provided increased sonication efficiency, decreased focal size, and equivalent targeting accuracy relative to CT-based focusing. EF aberration corrections were employed successfully for lesion formation in all 12 patients, 3 of whom had previously undergone unsuccessful TcMRgFUS thalamotomy via CT-based focusing. There were no adverse events related directly to the EF procedure. CONCLUSIONS EF is feasible and appears safe during TcMRgFUS thalamotomy for essential tremor and improves on the trans-skull focal quality provided by existing CT-based focusing methods. © 2020 International Parkinson and Movement Disorder Society.
Collapse
Affiliation(s)
- Ryan M Jones
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Yuexi Huang
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Ying Meng
- Division of Neurosurgery, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.,Department of Surgery, University of Toronto, Toronto, Ontario, Canada
| | - Nadia Scantlebury
- Division of Neurosurgery, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| | - Michael L Schwartz
- Division of Neurosurgery, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.,Department of Surgery, University of Toronto, Toronto, Ontario, Canada
| | - Nir Lipsman
- Division of Neurosurgery, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.,Department of Surgery, University of Toronto, Toronto, Ontario, Canada
| | - Kullervo Hynynen
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada.,Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.,Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
25
|
Fletcher SMP, Choi M, Ogrodnik N, O'Reilly MA. A Porcine Model of Transvertebral Ultrasound and Microbubble-Mediated Blood-Spinal Cord Barrier Opening. Am J Cancer Res 2020; 10:7758-7774. [PMID: 32685018 PMCID: PMC7359082 DOI: 10.7150/thno.46821] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Accepted: 06/05/2020] [Indexed: 12/17/2022] Open
Abstract
Blood-spinal cord barrier opening, using focused ultrasound and microbubbles, has the potential to improve drug delivery for the treatment of spinal cord pathologies. Delivering and detecting ultrasound through the spine is a challenge for clinical translation. We have previously developed short burst, phase keying exposures, which can be used in a dual-aperture configuration to address clinical scale targeting challenges. Here we demonstrate the use of these pulses for blood-spinal cord barrier opening, in vivo in pigs. Methods: The spinal cords of Yorkshire pigs (n=8) were targeted through the vertebral laminae, in the lower thoracic to upper lumbar region using focused ultrasound (486 kHz) and microbubbles. Four animals were treated with a combination of pulsed sinusoidal exposures (1.0-4.0 MPa, non-derated) and pulsed short burst, phase keying exposures (1.0-2.0 MPa, non-derated). Four animals were treated using ramped short burst, phase keying exposures (1.8-2.1 MPa, non-derated). A 250 kHz narrowband receiver was used to detect acoustic emissions from microbubbles. Blood-spinal cord barrier opening was assessed by the extravasation of Evans blue dye. Histological analysis of the spinal cords was used to assess tissue damage and excised vertebral samples were used in benchtop experiments. Results: Ramped short burst, phase keying exposures successfully modified the blood-spinal cord barrier at 16/24 targeted locations, as assessed by the extravasation of Evans blue dye. At 4 of these locations, opening was confirmed with minimal adverse effects observed through histology. Transmission measurements through excised vertebrae indicated a mean transmission of (47.0 ± 7.0 %) to the target. Conclusions: This study presents the first evidence of focused ultrasound-induced blood-spinal cord barrier opening in a large animal model, through the intact spine. This represents an important step towards clinical translation.
Collapse
|
26
|
Jones RM, Kamps S, Huang Y, Scantlebury N, Lipsman N, Schwartz ML, Hynynen K. Accumulated thermal dose in MRI-guided focused ultrasound for essential tremor: repeated sonications with low focal temperatures. J Neurosurg 2020; 132:1802-1809. [PMID: 31075781 PMCID: PMC7139920 DOI: 10.3171/2019.2.jns182995] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Accepted: 02/22/2019] [Indexed: 11/06/2022]
Abstract
OBJECTIVE The object of this study was to correlate lesion size with accumulated thermal dose (ATD) in transcranial MRI-guided focused ultrasound (MRgFUS) treatments of essential tremor with focal temperatures limited to 50°C-54°C. METHODS Seventy-five patients with medically refractory essential tremor underwent MRgFUS thalamotomy at the authors' institution. Intraoperative MR thermometry was performed to measure the induced temperature and thermal dose distributions (proton resonance frequency shift coefficient = -0.00909 ppm/°C). In 19 patients, it was not possible to raise the focal temperature above 54°C because of unfavorable skull characteristics and/or the pain associated with cranial heating. In this patient subset, sonications with focal temperatures between 50°C and 54°C were repeated (5.1 ± 1.5, mean ± standard deviation) to accumulate a sufficient thermal dose for lesion formation. The ATD profile sizes (17, 40, 100, 200, and 240 cumulative equivalent minutes at 43°C [CEM43]) calculated by combining axial MR thermometry data from individual sonications were correlated with the corresponding lesion sizes measured on axial T1-weighted (T1w) and T2-weighted (T2w) MR images acquired 1 day posttreatment. Manual corrections were applied to the MR thermometry data prior to thermal dose accumulation to compensate for off-resonance-induced spatial-shifting artifacts. RESULTS Mean lesion sizes measured on T2w MRI (5.0 ± 1.4 mm) were, on average, 28% larger than those measured on T1w MRI (3.9 ± 1.4 mm). The ATD thresholds found to provide the best correlation with lesion sizes measured on T2w and T1w MRI were 100 CEM43 (regression slope = 0.97, R2 = 0.66) and 200 CEM43 (regression slope = 0.98, R2 = 0.89), respectively, consistent with data from a previous study of MRgFUS thalamotomy via repeated sonications at higher focal temperatures (≥ 55°C). Two-way linear mixed-effects analysis revealed that dominant tremor subscores on the Fahn-Tolosa-Marin Clinical Rating Scale for Tremor (CRST) were statistically different from baseline at 3 months and 1 year posttreatment in both low-temperature (50°C-54°C) and high-temperature (≥ 55°C) patient cohorts. No significant fixed effect on the dominant tremor scores was found for the temperature cohort factor. CONCLUSIONS In transcranial MRgFUS thalamotomy for essential tremor, repeated sonications with focal temperatures between 50°C and 54°C can accumulate a sufficient thermal dose to generate lesions for clinically relevant tremor suppression up to 1 year posttreatment, and the ATD can be used to predict the size of the resulting ablation zones measured on MRI. These data will serve to guide future clinical MRgFUS brain procedures, particularly those in which focal temperatures are limited to below 55°C.
Collapse
Affiliation(s)
- Ryan M. Jones
- Physical Sciences Platform, Sunnybrook Research Institute, University of Toronto, Ontario, Canada
| | - Shona Kamps
- Physical Sciences Platform, Sunnybrook Research Institute, University of Toronto, Ontario, Canada
| | - Yuexi Huang
- Physical Sciences Platform, Sunnybrook Research Institute, University of Toronto, Ontario, Canada
| | - Nadia Scantlebury
- Division of Neurosurgery, Sunnybrook Health Sciences Centre, University of Toronto, Ontario, Canada
| | - Nir Lipsman
- Division of Neurosurgery, Sunnybrook Health Sciences Centre, University of Toronto, Ontario, Canada
- Department of Surgery, University of Toronto, Ontario, Canada
| | - Michael L. Schwartz
- Division of Neurosurgery, Sunnybrook Health Sciences Centre, University of Toronto, Ontario, Canada
- Department of Surgery, University of Toronto, Ontario, Canada
| | - Kullervo Hynynen
- Physical Sciences Platform, Sunnybrook Research Institute, University of Toronto, Ontario, Canada
- Department of Medical Biophysics, University of Toronto, Ontario, Canada
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Ontario, Canada
| |
Collapse
|
27
|
Jones RM, McMahon D, Hynynen K. Ultrafast three-dimensional microbubble imaging in vivo predicts tissue damage volume distributions during nonthermal brain ablation. Theranostics 2020; 10:7211-7230. [PMID: 32641988 PMCID: PMC7330857 DOI: 10.7150/thno.47281] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Accepted: 05/22/2020] [Indexed: 12/13/2022] Open
Abstract
Transcranial magnetic resonance imaging (MRI)-guided focused ultrasound (FUS) thermal ablation is under clinical investigation for non-invasive neurosurgery, though its use is restricted to central brain targets due primarily to skull heating effects. The combination of FUS and contrast agent microbubbles greatly reduces the ultrasound exposure levels needed to ablate brain tissue and may help facilitate the use of transcranial FUS ablation throughout the brain. However, sources of variability exist during microbubble-mediated FUS procedures that necessitate the continued development of systems and methods for online treatment monitoring and control, to ensure that excessive and/or off-target bioeffects are not induced from the exposures. Methods: Megahertz-rate three-dimensional (3D) microbubble imaging in vivo was performed during nonthermal ablation in rabbit brain using a clinical-scale prototype transmit/receive hemispherical phased array system. Results:In-vivo volumetric acoustic imaging over microsecond timescales uncovered spatiotemporal microbubble dynamics hidden by conventional whole-burst temporal averaging. Sonication-aggregate ultrafast 3D source field intensity data were predictive of microbubble-mediated tissue damage volume distributions measured post-treatment using MRI and confirmed via histopathology. Temporal under-sampling of acoustic emissions, which is common practice in the field, was found to impede performance and highlighted the importance of capturing adequate data for treatment monitoring and control purposes. Conclusion: The predictive capability of ultrafast 3D microbubble imaging, reported here for the first time, will enable future microbubble-mediated FUS treatments with unparalleled precision and accuracy, and will accelerate the clinical translation of nonthermal tissue ablation procedures both in the brain and throughout the body.
Collapse
Affiliation(s)
- Ryan M. Jones
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Dallan McMahon
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
| | - Kullervo Hynynen
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
28
|
Sukovich JR, Macoskey JJ, Lundt JE, Gerhardson TI, Hall TL, Xu Z. Real-Time Transcranial Histotripsy Treatment Localization and Mapping Using Acoustic Cavitation Emission Feedback. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:1178-1191. [PMID: 31976885 PMCID: PMC7398266 DOI: 10.1109/tuffc.2020.2967586] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Cavitation events generated during histotripsy therapy generate large acoustic cavitation emission (ACE) signals that can be detected through the skull. This article investigates the feasibility of using these ACE signals, acquired using the elements of a 500-kHz, 256-element hemispherical histotripsy transducer as receivers, to localize and map the cavitation activity in real time through the human skullcap during transcranial histotripsy therapy. The locations of the generated cavitation events predicted using the ACE feedback signals in this study were found to be accurate to within <1.5 mm of the centers of masses detected by optical imaging and found to lie to within the measured volumes of the generated cavitation events in >~80 % of cases. Localization results were observed to be biased in the prefocal direction of the histotripsy array and toward its transverse origin but were only weakly affected by focal steering location. The choice of skullcap and treatment pulse repetition frequency (PRF) were both observed to affect the accuracy of the localization results in the low PRF regime (1-10 Hz), but the localization accuracy was seen to stabilize at higher PRFs (≥10 Hz). Tests of the localization algorithm in vitro, for treatment delivered to a bovine brain sample mounted within the skullcap, revealed good agreement between the ACE feedback-generated treatment map and the morphological characteristics of the treated volume of the brain sample. Localization during experiments was achieved in real time for pulses delivered at rates up to 70 Hz, but benchmark tests indicate that the localization algorithm is scalable, indicating that higher rates are possible with more powerful hardware. The results of this article demonstrate the feasibility of using ACE feedback signals to localize and map transcranially generated cavitation events during histotripsy. Such capability has the potential to greatly simplify transcranial histotripsy treatments, as it may provide a non-MRI-based method for monitoring and localizing transcranial histotripsy treatments in real time.
Collapse
|
29
|
Deng L, Hughes A, Hynynen K. A Noninvasive Ultrasound Resonance Method for Detecting Skull Induced Phase Shifts May Provide a Signal for Adaptive Focusing. IEEE Trans Biomed Eng 2020; 67:2628-2637. [PMID: 31976875 DOI: 10.1109/tbme.2020.2967033] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE There may be a need to perform dynamic skull aberration corrections during the non-invasive high-intensity transcranial treatment with magnetic resonance imaging (MRI) -guided focused ultrasound in order to accurately and rapidly restore the focus in the brain. METHODS This could possibly be accomplished by using an ultrasound-based correction method based on the skulls' thickness resonance frequencies. The focus of a 500 kHz transducer was centered in the ex vivo human skull caps at different temperatures. The pulse-echoed signals reflected from the skulls were analyzed in the frequency domain to reveal the resonance frequencies for the phase shift calculation. The accuracy was compared to both hydrophone and computed tomography (CT) based analytical methods. RESULTS Around 73% of the measurements (n = 784) were in the optimal constructive interference region, with a 15° decrease in the average phase error compared to the previous study. In the best implementation, it performed approximately the same or better than the CT based analytical method currently in clinical use. Linear correlation was found between the resonance frequencies or skull induced phase shifts and the skull temperature with an average rate of -0.4 kHz/°C and 2.6 deg/°C, respectively. CONCLUSION The ultrasound based resonance method has shown the feasibility of detecting heating-induced changes of skull phase shift non-invasively and accurately. SIGNIFICANCE Since the technique can be made MRI compatible and integrated in the therapy arrays, it may enable temperature tracking and adaptive focusing during high-intensity transcranial ultrasound treatments, to prevent skull overheating and preserve the transcranial focusing integrity.
Collapse
|
30
|
Gentilal N, Salvador R, Miranda PC. Temperature control in TTFields therapy of GBM: impact on the duty cycle and tissue temperature. Phys Med Biol 2019; 64:225008. [PMID: 31671414 DOI: 10.1088/1361-6560/ab5323] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
In TTFields therapy, Optune® is used to deliver the electric field to the tumor via 4 transducer arrays. This device monitors the temperature of the transducers and reduces the current whenever a transducer reaches 41 °C. Our aim is to quantify Optune's duty cycle and to predict the steady-state temperature distribution in the head during GBM treatment. We used a realistic head model and the finite element method to solve Pennes equation and to simulate how Optune operates considering that current reduces to zero when the thermal limit is reached. The thermal impact was evaluated considering the maximum temperature reached by each tissue and using the CEM 43 °C metric. We observed that Optune switches the current on and off intermittently. In our model, one transducer reached the temperature limit quicker than the others and consequently it was the one that controlled current injection. This led to different duty cycles for the anterior-posterior and left-right array pairs. The thermal analysis indicated that the highest temperature in the model, 41.7 °C, was reached on the scalp under a transducer. However, TTFields may lead to significant changes only at the brain level such as BBB permeability increase, cerebral blood flow variation and changes in the concentration of some neurotransmitters. The duty cycle may be increased, e.g. by controlling the current at the transducer level. These predictions should be validated by comparison with experimental data and reconciled with the lack of evidence of thermal impact in clinical trials.
Collapse
Affiliation(s)
- Nichal Gentilal
- Institute of Biophysics and Biomedical Engineering, Faculdade de Ciências, Universidade de Lisboa, Campo Grande, 1749-016, Lisboa, Portugal. Author to whom correspondence should be addressed
| | | | | |
Collapse
|
31
|
Wang TR, Bond AE, Dallapiazza RF, Blanke A, Tilden D, Huerta TE, Moosa S, Prada FU, Elias WJ. Transcranial magnetic resonance imaging-guided focused ultrasound thalamotomy for tremor: technical note. Neurosurg Focus 2019; 44:E3. [PMID: 29385914 DOI: 10.3171/2017.10.focus17609] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Although the use of focused ultrasound (FUS) in neurosurgery dates to the 1950s, its clinical utility was limited by the need for a craniotomy to create an acoustic window. Recent technological advances have enabled efficient transcranial delivery of US. Moreover, US is now coupled with MRI to ensure precise energy delivery and monitoring. Thus, MRI-guided transcranial FUS lesioning is now being investigated for myriad neurological and psychiatric disorders. Among the first transcranial FUS treatments is thalamotomy for the treatment of various tremors. The authors provide a technical overview of FUS thalamotomy for tremor as well as important lessons learned during their experience with this emerging technology.
Collapse
Affiliation(s)
| | | | - Robert F Dallapiazza
- Division of Neurosurgery, Toronto Western Hospital University Health Network, Toronto, Ontario, Canada
| | | | | | - Thomas E Huerta
- Department of Radiology, Neuroradiology Division, University of Virginia Health System, Charlottesville, Virginia
| | | | - Francesco U Prada
- Department of Neurological Surgery, and.,Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico C. Besta, Milan, Italy
| | | |
Collapse
|
32
|
Sukovich JR, Cain CA, Pandey AS, Chaudhary N, Camelo-Piragua S, Allen SP, Hall TL, Snell J, Xu Z, Cannata JM, Teofilovic D, Bertolina JA, Kassell N, Xu Z. In vivo histotripsy brain treatment. J Neurosurg 2019; 131:1331-1338. [PMID: 30485186 PMCID: PMC6925659 DOI: 10.3171/2018.4.jns172652] [Citation(s) in RCA: 46] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2017] [Accepted: 04/23/2018] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Histotripsy is an ultrasound-based treatment modality relying on the generation of targeted cavitation bubble clouds, which mechanically fractionate tissue. The purpose of the current study was to investigate the in vivo feasibility, including dosage requirements and safety, of generating well-confined destructive lesions within the porcine brain utilizing histotripsy technology. METHODS Following a craniectomy to open an acoustic window to the brain, histotripsy pulses were delivered to generate lesions in the porcine cortex. Large lesions with a major dimension of up to 1 cm were generated to demonstrate the efficacy of histotripsy lesioning in the brain. Gyrus-confined lesions were generated at different applied dosages and under ultrasound imaging guidance to ensure that they were accurately targeted and contained within individual gyri. Clinical evaluation as well as MRI and histological outcomes were assessed in the acute (≤ 6 hours) and subacute (≤ 72 hours) phases of recovery. RESULTS Histotripsy was able to generate lesions with a major dimension of up to 1 cm in the cortex. Histotripsy lesions were seen to be well demarcated with sharp boundaries between treated and untreated tissues, with histological evidence of injuries extending ≤ 200 µm from their boundaries in all cases. In animals with lesions confined to the gyrus, no major hemorrhage or other complications resulting from treatment were observed. At 72 hours, MRI revealed minimal to no edema and no radiographic evidence of inflammatory changes in the perilesional area. Histological evaluation revealed the histotripsy lesions to be similar to subacute infarcts. CONCLUSIONS Histotripsy can be used to generate sharply defined lesions of arbitrary shapes and sizes in the swine cortex. Lesions confined to within the gyri did not lead to significant hemorrhage or edema responses at the treatment site in the acute or subacute time intervals.
Collapse
Affiliation(s)
- Jonathan R. Sukovich
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan
| | - Charles A. Cain
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan
| | - Aditya S. Pandey
- Department of Neurosurgery, University of Michigan, Ann Arbor, Michigan
| | - Neeraj Chaudhary
- Department of Radiology, University of Michigan, Ann Arbor, Michigan
| | | | - Steven P. Allen
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan
| | - Timothy L. Hall
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan
| | - John Snell
- Focused Ultrasound Foundation, Charlottesville, Virginia
- University of Virginia, Department of Neurosurgery, Charlottesville, Virginia
| | - Zhiyuan Xu
- University of Virginia, Department of Neurosurgery, Charlottesville, Virginia
| | | | | | | | - Neal Kassell
- Focused Ultrasound Foundation, Charlottesville, Virginia
| | - Zhen Xu
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan
| |
Collapse
|
33
|
Ferri M, Bravo JM, Redondo J, Jiménez-Gambín S, Jiménez N, Camarena F, Sánchez-Pérez JV. On the Evaluation of the Suitability of the Materials Used to 3D Print Holographic Acoustic Lenses to Correct Transcranial Focused Ultrasound Aberrations. Polymers (Basel) 2019; 11:E1521. [PMID: 31546807 PMCID: PMC6780887 DOI: 10.3390/polym11091521] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 09/13/2019] [Accepted: 09/16/2019] [Indexed: 11/16/2022] Open
Abstract
The correction of transcranial focused ultrasound aberrations is a relevant topic for enhancing various non-invasive medical treatments. Presently, the most widely accepted method to improve focusing is the emission through multi-element phased arrays; however, a new disruptive technology, based on 3D printed holographic acoustic lenses, has recently been proposed, overcoming the spatial limitations of phased arrays due to the submillimetric precision of the latest generation of 3D printers. This work aims to optimize this recent solution. Particularly, the preferred acoustic properties of the polymers used for printing the lenses are systematically analyzed, paying special attention to the effect of p-wave speed and its relationship to the achievable voxel size of 3D printers. Results from simulations and experiments clearly show that, given a particular voxel size, there are optimal ranges for lens thickness and p-wave speed, fairly independent of the emitted frequency, the transducer aperture, or the transducer-target distance.
Collapse
Affiliation(s)
- Marcelino Ferri
- Centro de Tecnologías Físicas, Universitat Politècnica de València, Camino de Vera S/N, 46020 Valencia, Spain.
| | - José María Bravo
- Centro de Tecnologías Físicas, Universitat Politècnica de València, Camino de Vera S/N, 46020 Valencia, Spain.
| | - Javier Redondo
- Instituto para la Gestión Integrada de las zonas Costeras, Universitat Politècnica de València, Carretera Nazaret-Oliva S/N, 46730 Valencia, Spain.
| | - Sergio Jiménez-Gambín
- Instituto de Instrumentación para Imagen Molecular, Centro Mixto CSIC-Universitat Politècnica de València, Camino de Vera S/N, 46022 València, Spain.
| | - Noé Jiménez
- Instituto de Instrumentación para Imagen Molecular, Centro Mixto CSIC-Universitat Politècnica de València, Camino de Vera S/N, 46022 València, Spain.
| | - Francisco Camarena
- Instituto de Instrumentación para Imagen Molecular, Centro Mixto CSIC-Universitat Politècnica de València, Camino de Vera S/N, 46022 València, Spain.
| | - Juan Vicente Sánchez-Pérez
- Centro de Tecnologías Físicas, Universitat Politècnica de València, Camino de Vera S/N, 46020 Valencia, Spain.
| |
Collapse
|
34
|
Kleven RT, Karani KB, Salido NG, Shekhar H, Haworth KJ, Mast TD, Tadesse DG, Holland CK. The effect of 220 kHz insonation scheme on rt-PA thrombolytic efficacy in vitro. Phys Med Biol 2019; 64:165015. [PMID: 31189149 DOI: 10.1088/1361-6560/ab293b] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Ultrasound-enhanced recombinant tissue plasminogen activator (rt-PA) thrombolysis is under development as an adjuvant to ischemic stroke therapy. The goal of this study was to design a pulsed ultrasound (US) exposure scheme that reduced intracranial constructive interference and tissue heating, and maintained thrombolytic efficacy relative to continuous wave (CW) insonation. Three 220 kHz US schemes were evaluated, two pulsed insonation schemes (15 cycles, 68 µs pulse duration, 33% or 62.5% duty cycle) and an intermittent CW insonation scheme (50 s active, 30 s quiescent) over a 30-min treatment period. An in silico study using a finite-difference model of transcranial US propagation was performed to estimate the intracranial acoustic field and temperature rise in the skull for each insonation scheme. In vitro measurements with flow were performed to assess thrombolysis using time-lapse microscopy. Intracranial constructive interference was not reduced with pulsed US using a pulse length of 15 cycles compared to intermittent CW US. The 33.3% duty cycle pulsed US scheme reduced heating in the temporal bone as much as 60% relative to the intermittent CW scheme. All insonation schemes promoted sustained stable cavitation in vitro and augmented thrombolysis compared to rt-PA alone (p < 0.05). Ultraharmonic (UH) and harmonic cumulative energy over a 30 min treatment period was significantly higher (p < 0.05) for the intermittent CW US scheme compared to either pulsed US scheme. Despite the difference in cavitation emissions, no difference was observed in the clot lysis between the three US schemes. These findings demonstrate that a 33.3% duty cycle pulsed US scheme with a 15-cycle burst can reduce bone heating and achieve equivalent thrombolytic efficacy as an intermittent CW scheme.
Collapse
Affiliation(s)
- Robert T Kleven
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, United States of America. Robert Kleven, CVC 3921, 0586, 231 Albert Sabin Way, Cincinnati, OH 45267-0586, United States of America. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | | | |
Collapse
|
35
|
Chang KW, Park YS, Chang JW. Skull Factors Affecting Outcomes of Magnetic Resonance-Guided Focused Ultrasound for Patients with Essential Tremor. Yonsei Med J 2019; 60:768-773. [PMID: 31347332 PMCID: PMC6660436 DOI: 10.3349/ymj.2019.60.8.768] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/03/2019] [Revised: 05/03/2019] [Accepted: 05/29/2019] [Indexed: 11/27/2022] Open
Abstract
PURPOSE Magnetic resonance-guided focused ultrasound (MRgFUS) thalamotomy has become a standard treatment for medically intractable essential tremor (ET). Skull density ratio (SDR) and skull volume in patients with ET are currently considered useful indicators of the successful application of MRgFUS. We compared the clinical outcomes of MRgFUS thalamotomy with SDR above 0.4 and 0.45. We also described patterns of SDR and skull volume in Korean patients with ET who were eligible to be screened for MRgFUS. MATERIALS AND METHODS In screening 318 ET patients, we evaluated patterns of skull density and skull volume according to age and sex. Fifty patients with ET were treated with MRgFUS. We investigated the effects of SDR and skull volume on treatment parameters and the outcomes of ET. RESULTS The mean SDR of the 318 ET patients was 0.45±0.11, and that for skull volume was 315.74±40.95 cm³. The male patients had a higher SDR than female patients (p=0.047). Skull volume significantly decreased with aging. SDR and skull volume exhibited a linear negative relationship. Among therapeutic parameters, maximal temperature was positively related to SDR, while sonication number was not related to either SDR or skull volume. Tremor outcome was also not related to SDR or skull volume. CONCLUSION SDR varied widely from 0.11 to 0.73, and men had a higher SDR. Therapeutic parameters and clinical outcomes were not affected by SDR or skull volume.
Collapse
Affiliation(s)
- Kyung Won Chang
- Department of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul, Korea
| | - Yong Sook Park
- Department of Neurosurgery, Brain Research Institute, Chung-Ang University College of Medicine, Seoul, Korea
| | - Jin Woo Chang
- Department of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul, Korea.
| |
Collapse
|
36
|
Wu SK, Santos MA, Marcus SL, Hynynen K. MR-guided Focused Ultrasound Facilitates Sonodynamic Therapy with 5-Aminolevulinic Acid in a Rat Glioma Model. Sci Rep 2019; 9:10465. [PMID: 31320671 PMCID: PMC6639400 DOI: 10.1038/s41598-019-46832-2] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2019] [Accepted: 07/03/2019] [Indexed: 11/25/2022] Open
Abstract
Glioblastoma multiforme (GBM) continues to have a dismal prognosis and significant efforts are being made to develop more effective treatment methods. Sonodynamic therapy (SDT) is an emerging modality for cancer treatment which combines ultrasound with sonosensitizers to produce a localized cytotoxic effect. It has long been known that ultrasound exposure can cause both thermal and non-thermal bioeffects and it remains an open question to what degree does temperature impact the efficacy of SDT. In order to optimize the ultrasound parameters of SDT, transcranial MRI-guided focused ultrasound (MRgFUS) and real-time MRI thermometry were used to monitor the therapy in a rat brain tumor model. Experiments were performed using a C6 intracranial glioma tumor model in 37 male Sprague Dawley rats. Treatments were performed about 7 days following tumor implantation when the tumor reached 1-3 mm in diameter as determined by MRI. 5-aminolevulinic acid (5-ALA) was injected at a dose of 60 mg/kg six hours before sonication. MRgFUS at 1.06 MHz was delivered continuously at an in situ spatial-peak temporal-average intensity of 5.5 W/cm2 for 20 min. MR thermometry was acquired to monitor the temperature change in the brain during sonication. The tumor growth response for animals receiving 5-ALA alone, FUS alone, 5-ALA + FUS and a sham control group were evaluated with MRI every week following treatment. During 20 min of MRgFUS at 5.5 W/cm2, the temperature within the targeted brain tumor was elevated from 32.3 ± 0.5 °C and 37.2 ± 0.7 °C to 33.2 ± 0.9 °C and 38.4 ± 1.1 °C, respectively. Both the tumor growth inhibition and survival were significantly improved in the 5-ALA + FUS group with 32 °C or 37 °C as the starting core body (rectal) temperature. 5-ALA alone and FUS alone did not improve survival. These promising results indicate that relatively low power continuous wave transcranial MRgFUS in conjunction with 5-ALA can produce an inhibitory effect on rat brain tumor growth in the absence of thermal dose. Further investigation of the ultrasound parameters is needed to improve the therapeutic efficacy of MRgFUS and 5-ALA.
Collapse
Affiliation(s)
- Sheng-Kai Wu
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON, Canada.
- Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada.
| | - Marc A Santos
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada
| | - Stuart L Marcus
- Sun Pharmaceutical Industries Inc., Princeton, New Jersey, United States
| | - Kullervo Hynynen
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON, Canada.
- Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada.
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON, Canada.
| |
Collapse
|
37
|
Schwartz ML, Yeung R, Huang Y, Lipsman N, Krishna V, Jain JD, Chapman MG, Lozano AM, Hynynen K. Skull bone marrow injury caused by MR-guided focused ultrasound for cerebral functional procedures. J Neurosurg 2019; 130:758-762. [PMID: 29726769 DOI: 10.3171/2017.11.jns17968] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2017] [Accepted: 11/10/2017] [Indexed: 11/06/2022]
Abstract
OBJECTIVE One patient for whom an MR-guided focused ultrasound (MRgFUS) pallidotomy was attempted was discovered to have multiple new skull lesions with the appearance of infarcts on the MRI scan 3 months after his attempted treatment. The authors conducted a retrospective review of the first 30 patients treated with MRgFUS to determine the incidence of skull lesions in patients undergoing these procedures and to consider possible causes. METHODS A retrospective review of the MRI scans of the first 30 patients, 1 attempted pallidotomy and 29 ventral intermediate nucleus thalamotomies, was conducted. The correlation of the mean skull density ratio (SDR) and the maximum energy applied in the production or attempted production of a brain lesion was examined. RESULTS Of 30 patients treated with MRgFUS for movement disorders, 7 were found to have new skull lesions that were not present prior to treatment and not visible on the posttreatment day 1 MRI scan. Discomfort was reported at the time of treatment by some patients with and without skull lesions. All patients with skull lesions were completely asymptomatic. There was no correlation between the mean SDR and the presence or absence of skull lesions, but the maximum energy applied with the Exablate system was significantly greater in patients with skull lesions than in those without. CONCLUSIONS It is known that local skull density, thickness, and SDR vary from location to location. Sufficient energy transfer resulting in local heating sufficient to produce a bone lesion may occur in regions of low SDR. A correlation of lesion location and local skull properties should be made in future studies.
Collapse
Affiliation(s)
| | - Robert Yeung
- 2Sunnybrook Health Sciences Centre
- Departments of3Medical Imaging and
| | - Yuexi Huang
- 4Physical Sciences Platform, Sunnybrook Research Institute; and
| | - Nir Lipsman
- 1Division of Neurosurgery and
- 2Sunnybrook Health Sciences Centre
| | - Vibhor Krishna
- 5Department of Neurosurgery, The Ohio State University, Columbus, Ohio
| | | | | | - Andres M Lozano
- 1Division of Neurosurgery and
- 7Toronto Western Hospital, Toronto, Ontario, Canada; and
| | - Kullervo Hynynen
- 4Physical Sciences Platform, Sunnybrook Research Institute; and
- 8Medical Biophysics, and
- 9Institute of Biomaterials and Biomedical Engineering, University of Toronto
| |
Collapse
|
38
|
Fu F, Sui B, Liu L, Su Y, Sun S, Li Y. Quantitative assessment of local perfusion change in acute intracerebral hemorrhage areas with and without "dynamic spot sign" using CT perfusion imaging. Acta Radiol 2019; 60:367-373. [PMID: 29871494 DOI: 10.1177/0284185118780893] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Positive "dynamic spot sign" has been proven to be a potential risk factor for acute intracerebral hemorrhage (ICH) expansion, but local perfusion change has not been quantitatively investigated. PURPOSE To quantitatively evaluate perfusion changes at the ICH area using computed tomography perfusion (CTP) imaging. MATERIAL AND METHODS Fifty-three patients with spontaneous ICH were recruited. Unenhanced computed tomography (NCCT), CTP within 6 h, and follow-up NCCT were performed for 21 patients in the "spot sign"-positive group and 32 patients in the control group. Cerebral perfusion change was quantitatively measured on regional cerebral blood flow/regional cerebral blood volume (rCBF/rCBV) maps. Regions of interest (ROIs) were set at the "spot-sign" region and the whole hematoma area for "spot-sign"-positive cases, and at one of the highest values of three interested areas and the whole hematoma area for the control group. Hematoma expansion was determined by follow-up NCCT. RESULTS For the "spot-sign"-positive group, the average rCBF (rCBV) values at the "spot-sign" region and the whole hematoma area were 21.34 ± 15.24 mL/min/100 g (21.64 ± 21.48 mL/100g) and 5.78 ± 6.32 mL/min/100 g (6.07 ± 5.45 mL/100g); for the control group, the average rCBF (rCBV) values at the interested area and whole hematoma area were 2.50 ± 1.83 mL/min/100 g (3.13 ± 1.96 mL/100g) and 3.02 ± 1.80 mL/min/100 g (3.40 ± 1.44 mL/100g), respectively. Average rCBF and rCBV values of the "spot-sign" region were significantly different from other regions ( P < 0.001; P = 0.004). The average volumes of hematoma expansion in the "spot-sign"-positive and control groups were 25.24 ± 19.38 mL and -0.41 ± 1.34 mL, respectively. CONCLUSION The higher perfusion change at ICH on CTP images may reflect the contrast extravasation and be associated with the hematoma expansion.
Collapse
Affiliation(s)
- Fan Fu
- Neuroradiology Department, Beijing Tiantan Hospital, Capital Medical University, Beijing, PR China
| | - Binbin Sui
- Neuroradiology Department, Beijing Tiantan Hospital, Capital Medical University, Beijing, PR China
| | - Liping Liu
- Neuroradiology Department, Beijing Tiantan Hospital, Capital Medical University, Beijing, PR China
| | - Yaping Su
- Neuroradiology Department, Beijing Tiantan Hospital, Capital Medical University, Beijing, PR China
| | - Shengjun Sun
- Neuroradiology Department, Beijing Tiantan Hospital, Capital Medical University, Beijing, PR China
| | - Yingying Li
- Neuroradiology Department, Beijing Tiantan Hospital, Capital Medical University, Beijing, PR China
| |
Collapse
|
39
|
Ferri M, Bravo JM, Redondo J, Sánchez-Pérez JV. Enhanced Numerical Method for the Design of 3-D-Printed Holographic Acoustic Lenses for Aberration Correction of Single-Element Transcranial Focused Ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:867-884. [PMID: 30600128 DOI: 10.1016/j.ultrasmedbio.2018.10.022] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2018] [Revised: 10/19/2018] [Accepted: 10/19/2018] [Indexed: 06/09/2023]
Abstract
The correction of transcranial focused ultrasound aberrations is a relevant issue for enhancing various non-invasive medical treatments. The emission through multi-element phased arrays has been the most widely accepted method to improve focusing in recent years; however, the number and size of transducers represent a bottleneck that limits the focusing accuracy of the technique. To overcome this limitation, a new disruptive technology, based on 3-D-printed acoustic lenses, has recently been proposed. As the submillimeter precision of the latest generation of 3-D printers has been proven to overcome the spatial limitations of phased arrays, a new challenge is to improve the accuracy of the numerical simulations required to design this type of ultrasound lens. In the study described here, we evaluated two improvements in the numerical model applied in previous works for the design of 3-D-printed lenses: (i) allowing the propagation of shear waves in the skull by means of its simulation as an isotropic solid and (ii) introduction of absorption into the set of equations that describes the dynamics of the wave in both fluid and solid media. The results obtained in the numerical simulations are evidence that the inclusion of both s-waves and absorption significantly improves focusing.
Collapse
Affiliation(s)
- Marcelino Ferri
- Centro de Tecnologías Físicas, Universidad Politécnica de Valencia, Valencia, Spain.
| | - José M Bravo
- Centro de Tecnologías Físicas, Universidad Politécnica de Valencia, Valencia, Spain
| | - Javier Redondo
- Instituto para la Gestión Integrada de las zonas Costeras, Universidad Politécnica de Valencia, Valencia, Spain
| | - Juan V Sánchez-Pérez
- Centro de Tecnologías Físicas, Universidad Politécnica de Valencia, Valencia, Spain
| |
Collapse
|
40
|
Jones RM, Hynynen K. Advances in acoustic monitoring and control of focused ultrasound-mediated increases in blood-brain barrier permeability. Br J Radiol 2019; 92:20180601. [PMID: 30507302 DOI: 10.1259/bjr.20180601] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Transcranial focused ultrasound (FUS) combined with intravenously circulating microbubbles can transiently and selectively increase blood-brain barrier permeability to enable targeted drug delivery to the central nervous system, and is a technique that has the potential to revolutionize the way neurological diseases are managed in medical practice. Clinical testing of this approach is currently underway in patients with brain tumors, early Alzheimer's disease, and amyotrophic lateral sclerosis. A major challenge that needs to be addressed in order for widespread clinical adoption of FUS-mediated blood-brain barrier permeabilization to occur is the development of systems and methods for real-time treatment monitoring and control, to ensure that safe and effective acoustic exposure levels are maintained throughout the procedures. This review gives a basic overview of the oscillation dynamics, acoustic emissions, and biological effects associated with ultrasound-stimulated microbubbles in vivo, and provides a summary of recent advances in acoustic-based strategies for detecting, controlling, and mapping microbubble activity in the brain. Further development of next-generation clinical FUS brain devices tailored towards microbubble-mediated applications is warranted and required for translation of this potentially disruptive technology into routine clinical practice.
Collapse
Affiliation(s)
- Ryan M Jones
- 1 Physical Sciences Platform, Sunnybrook Research Institute , Toronto, ON , Canada
| | - Kullervo Hynynen
- 1 Physical Sciences Platform, Sunnybrook Research Institute , Toronto, ON , Canada.,2 Department of Medical Biophysics, University of Toronto , Toronto, ON , Canada.,3 Institute of Biomaterials and Biomedical Engineering, University of Toronto , Toronto, ON , Canada
| |
Collapse
|
41
|
Fletcher SMP, O’Reilly MA. Analysis of Multifrequency and Phase Keying Strategies for Focusing Ultrasound to the Human Vertebral Canal. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:2322-2331. [PMID: 30273151 PMCID: PMC6309482 DOI: 10.1109/tuffc.2018.2872171] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Focused ultrasound has been shown to increase the permeability of the blood-brain barrier and its feasibility for opening the blood-spinal cord barrier has also been demonstrated in small animal models, with great potential to impact the treatment of spinal cord (SC) disorders. For clinical translation, challenges to transvertebral focusing of ultrasound energy on the human spinal canal, such as a focal depth of field and standing-wave formation, must be addressed. A dual-aperture approach using multifrequency and phase-shift keying (PSK) strategies for achieving a controlled focus in human thoracic vertebrae was investigated through numerical simulations and benchtop experiments in ex vivo human vertebrae. An ~85% reduction in the focal depth of field was achieved compared to a single-aperture approach at 564 kHz. Short-burst (two-cycle) excitations in combination with PSK were found to suppress the formation of standing waves in ex vivo human thoracic vertebrae when focusing through the vertebral laminae. The results make an important contribution toward the development of a clinical-scale approach for targeting ultrasound therapy to the SC.
Collapse
Affiliation(s)
- Stecia-Marie P. Fletcher
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto,
ON, Canada and the Department of Medical Biophysics, University of Toronto,
ON, Canada ()
| | - Meaghan A. O’Reilly
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto,
ON, Canada and the Department of Medical Biophysics, University of Toronto,
ON, Canada ()
| |
Collapse
|
42
|
Lipsman N, Meng Y, Bethune AJ, Huang Y, Lam B, Masellis M, Herrmann N, Heyn C, Aubert I, Boutet A, Smith GS, Hynynen K, Black SE. Blood-brain barrier opening in Alzheimer's disease using MR-guided focused ultrasound. Nat Commun 2018; 9:2336. [PMID: 30046032 PMCID: PMC6060168 DOI: 10.1038/s41467-018-04529-6] [Citation(s) in RCA: 577] [Impact Index Per Article: 82.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2017] [Accepted: 05/04/2018] [Indexed: 12/25/2022] Open
Abstract
Magnetic resonance-guided focused ultrasound in combination with intravenously injected microbubbles has been shown to transiently open the blood-brain barrier, and reduce beta-amyloid and tau pathology in animal models of Alzheimer's disease. Here, we used focused ultrasound to open the blood-brain barrier in five patients with early to moderate Alzheimer's disease in a phase I safety trial. In all patients, the blood-brain barrier within the target volume was safely, reversibly, and repeatedly opened. Opening the blood-brain barrier did not result in serious clinical or radiographic adverse events, as well as no clinically significant worsening on cognitive scores at three months compared to baseline. Beta-amyloid levels were measured before treatment using [18F]-florbetaben PET to confirm amyloid deposition at the target site. Exploratory analysis suggested no group-wise changes in amyloid post-sonication. The results of this safety and feasibility study support the continued investigation of focused ultrasound as a potential novel treatment and delivery strategy for patients with Alzheimer's disease.
Collapse
Affiliation(s)
- Nir Lipsman
- Division of Neurosurgery, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada.
- Hurvitz Brain Sciences Research Program, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada.
- Harquail Centre for Neuromodulation, Sunnybrook Research Institute, Toronto, M4N 3M5, Canada.
| | - Ying Meng
- Division of Neurosurgery, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada
- Hurvitz Brain Sciences Research Program, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada
| | - Allison J Bethune
- Hurvitz Brain Sciences Research Program, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada
- Harquail Centre for Neuromodulation, Sunnybrook Research Institute, Toronto, M4N 3M5, Canada
| | - Yuexi Huang
- Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada
| | - Benjamin Lam
- Hurvitz Brain Sciences Research Program, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada
- Division of Neurology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada
| | - Mario Masellis
- Hurvitz Brain Sciences Research Program, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada
- Division of Neurology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada
| | - Nathan Herrmann
- Hurvitz Brain Sciences Research Program, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada
- Division of Geriatric Psychiatry, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada
| | - Chinthaka Heyn
- Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada
- Department of Medical Imaging, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada
| | - Isabelle Aubert
- Hurvitz Brain Sciences Research Program, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada
- Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, M5S 3H7, Canada
| | - Alexandre Boutet
- Department of Medical Imaging, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada
| | - Gwenn S Smith
- Department of Psychiatry and Behavioral Sciences and Radiology and Radiological Sciences, Johns Hopkins University, Baltimore, MD, 21218, USA
| | - Kullervo Hynynen
- Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, M5S 3H7, Canada
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, M5S 3H7, Canada
| | - Sandra E Black
- Hurvitz Brain Sciences Research Program, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada
- Division of Neurology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, M4N 3M5, Canada
| |
Collapse
|
43
|
Hughes A, Huang Y, Schwartz ML, Hynynen K. The reduction in treatment efficiency at high acoustic powers during MR-guided transcranial focused ultrasound thalamotomy for Essential Tremor. Med Phys 2018; 45:2925-2936. [PMID: 29758099 DOI: 10.1002/mp.12975] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2018] [Revised: 05/07/2018] [Accepted: 05/07/2018] [Indexed: 12/19/2022] Open
Abstract
PURPOSE To analyze clinical data indicating a reduction in the induced energy-temperature efficiency relationship during transcranial focused ultrasound (FUS) Essential Tremor (ET) thalamotomy treatments at higher acoustic powers, establish its relationship with the spatial distribution of the focal temperature elevation, and explore its cause. METHODS A retrospective observational study of patients (n = 19) treated between July 2015 and August 2016 for (ET) by FUS thalamotomy was performed. These data were analyzed to compare the relationships between the applied power, the applied energy, the resultant peak temperature achieved in the brain, and the dispersion of the focal volume. Full ethics approval was received and all patients provided signed informed consent forms before the initiation of the study. Computer simulations, animal experiments, and clinical system tests were performed to determine the effects of skull heating, changes in brain properties and transducer acoustic output, respectively. All animal procedures were approved by the Animal Care and Use Committee and conformed to the guidelines set out by the Canadian Council on Animal Care. MATLAB was used to perform statistical analysis. RESULTS The reduction in the energy efficiency relationship during treatment correlates with the increase in size of the focal volume at higher sonication powers. A linear relationship exists showing that a decrease in treatment efficiency correlates positively with an increase in the focal size over the course of treatment (P < 0.01), supporting the hypothesis of transient skull and tissue heating causing acoustic aberrations leading to a decrease in efficiency. Changes in thermal conductivity, perfusion, absorption rates in the brain, as well as ultrasound transducer acoustic output levels were found to have minimal effects on the observed reduction in efficiency. CONCLUSIONS The reduction in energy-temperature efficiency during high-power FUS treatments correlated with observed increases in the size of the focal volume and is likely caused by transient changes in the tissue and skull during heating.
Collapse
Affiliation(s)
- Alec Hughes
- Department of Medical Biophysics, University of Toronto, 101 College St, Room 15-701, Toronto, Canada.,Physical Sciences Platform, Sunnybrook Research Institute, Room C713, 2075 Bayview Ave, Toronto, Canada
| | - Yuexi Huang
- Physical Sciences Platform, Sunnybrook Research Institute, Room C713, 2075 Bayview Ave, Toronto, Canada
| | - Michael L Schwartz
- Division of Neurosurgery, Department of Surgery, Sunnybrook Health Sciences Centre, Toronto, Canada
| | - Kullervo Hynynen
- Department of Medical Biophysics, University of Toronto, 101 College St, Room 15-701, Toronto, Canada.,Physical Sciences Platform, Sunnybrook Research Institute, Room C713, 2075 Bayview Ave, Toronto, Canada
| |
Collapse
|
44
|
|
45
|
Abstract
The term hyperthermia broadly refers to either an abnormally high fever or the treatment of a disease by the induction of fever. Its effect depends on the temperature and exposure time. The increasing number of applications and clinical trials at universities, clinics, and hospitals prove the feasibility and applicability of clinical therapeutic hyperthermia. This chapter aims to outline and discuss the means by which electromagnetic energy and other techniques can provide elevation of temperature within the human body. Because of the individual characteristic of each type of treatment, different modalities of heating systems have evolved. The chapter concludes with a discussion of challenges and opportunities for further improvement in technology and routine clinical application.
Collapse
Affiliation(s)
- Riadh W Y Habash
- School of Electrical Engineering and Computer Science, and McLaughlin Centre for Population Health Risk Assessment, University of Ottawa, Ottawa, ON, Canada.
| |
Collapse
|
46
|
Vyas U, Ghanouni P, Halpern CH, Elias J, Pauly KB. Predicting variation in subject thermal response during transcranial magnetic resonance guided focused ultrasound surgery: Comparison in seventeen subject datasets. Med Phys 2017; 43:5170. [PMID: 27587047 DOI: 10.1118/1.4955436] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE In transcranial magnetic resonance-guided focused ultrasound (tcMRgFUS) treatments, the acoustic and spatial heterogeneity of the skull cause reflection, absorption, and scattering of the acoustic beams. These effects depend on skull-specific parameters and can lead to patient-specific thermal responses to the same transducer power. In this work, the authors develop a simulation tool to help predict these different experimental responses using 3D heterogeneous tissue models based on the subject CT images. The authors then validate and compare the predicted skull efficiencies to an experimental metric based on the subject thermal responses during tcMRgFUS treatments in a dataset of seventeen human subjects. METHODS Seventeen human head CT scans were used to create tissue acoustic models, simulating the effects of reflection, absorption, and scattering of the acoustic beam as it propagates through a heterogeneous skull. The hybrid angular spectrum technique was used to model the acoustic beam propagation of the InSightec ExAblate 4000 head transducer for each subject, yielding maps of the specific absorption rate (SAR). The simulation assumed the transducer was geometrically focused to the thalamus of each subject, and the focal SAR at the target was used as a measure of the simulated skull efficiency. Experimental skull efficiency for each subject was calculated using the thermal temperature maps from the tcMRgFUS treatments. Axial temperature images (with no artifacts) were reconstructed with a single baseline, corrected using a referenceless algorithm. The experimental skull efficiency was calculated by dividing the reconstructed temperature rise 8.8 s after sonication by the applied acoustic power. RESULTS The simulated skull efficiency using individual-specific heterogeneous models predicts well (R(2) = 0.84) the experimental energy efficiency. CONCLUSIONS This paper presents a simulation model to predict the variation in thermal responses measured in clinical ctMRGFYS treatments while being computationally feasible.
Collapse
Affiliation(s)
- Urvi Vyas
- Department of Radiology, Stanford University, Stanford, California 94305
| | - Pejman Ghanouni
- Department of Radiology, Stanford University, Stanford, California 94305
| | - Casey H Halpern
- Department of Radiology, Stanford University, Stanford, California 94305
| | - Jeff Elias
- Department of Neurological Surgery, University of Virginia, Charlottesville, Virginia 22908
| | - Kim Butts Pauly
- Department of Radiology, Stanford University, Stanford, California 94305
| |
Collapse
|
47
|
Hughes A, Huang Y, Pulkkinen A, Schwartz ML, Lozano AM, Hynynen K. A numerical study on the oblique focus in MR-guided transcranial focused ultrasound. Phys Med Biol 2016; 61:8025-8043. [PMID: 27779134 PMCID: PMC5102068 DOI: 10.1088/0031-9155/61/22/8025] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Recent clinical data showing thermal lesions from treatments of essential tremor using MR-guided transcranial focused ultrasound shows that in many cases the focus is oblique to the main axis of the phased array. The potential for this obliquity to extend the focus into lateral regions of the brain has led to speculation as to the cause of the oblique focus, and whether it is possible to realign the focus. Numerical simulations were performed on clinical export data to analyze the causes of the oblique focus and determine methods for its correction. It was found that the focal obliquity could be replicated with the numerical simulations to within [Formula: see text] of the clinical cases. It was then found that a major cause of the focal obliquity was the presence of sidelobes, caused by an unequal deposition of power from the different transducer elements in the array at the focus. In addition, it was found that a 65% reduction in focal obliquity was possible using phase and amplitude corrections. Potential drawbacks include the higher levels of skull heating required when modifying the distribution of power among the transducer elements, and the difficulty at present in obtaining ideal phase corrections from CT information alone. These techniques for the reduction of focal obliquity can be applied to other applications of transcranial focused ultrasound involving lower total energy deposition, such as blood-brain barrier opening, where the issue of skull heating is minimal.
Collapse
Affiliation(s)
- Alec Hughes
- Department of Medical Biophysics, University of Toronto, Toronto, Canada
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada
| | - Yuexi Huang
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada
| | - Aki Pulkkinen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Michael L Schwartz
- Division of Neurosurgery, Department of Surgery, Sunnybrook Health Sciences Centre, Toronto, Canada
| | - Andres M Lozano
- Division of Neurosurgery, Department of Surgery, Krembil Neuroscience Centre, Toronto Western Hospital, Toronto, Canada
| | - Kullervo Hynynen
- Department of Medical Biophysics, University of Toronto, Toronto, Canada
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada
| |
Collapse
|
48
|
Top CB, White PJ, McDannold NJ. Nonthermal ablation of deep brain targets: A simulation study on a large animal model. Med Phys 2016; 43:870-82. [PMID: 26843248 PMCID: PMC4723413 DOI: 10.1118/1.4939809] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Thermal ablation with transcranial MRI-guided focused ultrasound (FUS) is currently limited to central brain targets because of heating and other beam effects caused by the presence of the skull. Recently, it was shown that it is possible to ablate tissues without depositing thermal energy by driving intravenously administered microbubbles to inertial cavitation using low-duty-cycle burst sonications. A recent study demonstrated that this ablation method could ablate tissue volumes near the skull base in nonhuman primates without thermally damaging the nearby bone. However, blood-brain disruption was observed in the prefocal region, and in some cases, this region contained small areas of tissue damage. The objective of this study was to analyze the experimental model with simulations and to interpret the cause of these effects. METHODS The authors simulated prior experiments where nonthermal ablation was performed in the brain in anesthetized rhesus macaques using a 220 kHz clinical prototype transcranial MRI-guided FUS system. Low-duty-cycle sonications were applied at deep brain targets with the ultrasound contrast agent Definity. For simulations, a 3D pseudospectral finite difference time domain tool was used. The effects of shear mode conversion, focal steering, skull aberrations, nonlinear propagation, and the presence of skull base on the pressure field were investigated using acoustic and elastic wave propagation models. RESULTS The simulation results were in agreement with the experimental findings in the prefocal region. In the postfocal region, however, side lobes were predicted by the simulations, but no effects were evident in the experiments. The main beam was not affected by the different simulated scenarios except for a shift of about 1 mm in peak position due to skull aberrations. However, the authors observed differences in the volume, amplitude, and distribution of the side lobes. In the experiments, a single element passive cavitation detector was used to measure the inertial cavitation threshold and to determine the pressure amplitude to use for ablation. Simulations of the detector's acoustic field suggest that its maximum sensitivity was in the lower part of the main beam, which may have led to excessive exposure levels in the experiments that may have contributed to damage in the prefocal area. CONCLUSIONS Overall, these results suggest that case-specific full wave simulations before the procedure can be useful to predict the focal and the prefocal side lobes and the extent of the resulting bioeffects produced by nonthermal ablation. Such simulations can also be used to optimally position passive cavitation detectors. The disagreement between the simulations and the experiments in the postfocal region may have been due to shielding of the ultrasound field due to microbubble activity in the focal region. Future efforts should include the effects of microbubble activity and vascularization on the pressure field.
Collapse
Affiliation(s)
- Can Barış Top
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 221 Longwood Avenue, Boston, Massachusetts 02115
| | - P Jason White
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 221 Longwood Avenue, Boston, Massachusetts 02115
| | - Nathan J McDannold
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 221 Longwood Avenue, Boston, Massachusetts 02115
| |
Collapse
|
49
|
Hynynen K, Jones RM. Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy. Phys Med Biol 2016; 61:R206-48. [PMID: 27494561 PMCID: PMC5022373 DOI: 10.1088/0031-9155/61/17/r206] [Citation(s) in RCA: 75] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Focused ultrasound offers a non-invasive way of depositing acoustic energy deep into the body, which can be harnessed for a broad spectrum of therapeutic purposes, including tissue ablation, the targeting of therapeutic agents, and stem cell delivery. Phased array transducers enable electronic control over the beam geometry and direction, and can be tailored to provide optimal energy deposition patterns for a given therapeutic application. Their use in combination with modern medical imaging for therapy guidance allows precise targeting, online monitoring, and post-treatment evaluation of the ultrasound-mediated bioeffects. In the past there have been some technical obstacles hindering the construction of large aperture, high-power, densely-populated phased arrays and, as a result, they have not been fully exploited for therapy delivery to date. However, recent research has made the construction of such arrays feasible, and it is expected that their continued development will both greatly improve the safety and efficacy of existing ultrasound therapies as well as enable treatments that are not currently possible with existing technology. This review will summarize the basic principles, current statures, and future potential of image-guided ultrasound phased arrays for therapy.
Collapse
Affiliation(s)
- Kullervo Hynynen
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada. Department of Medical Biophysics, University of Toronto, Toronto, Canada. Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Canada
| | | |
Collapse
|
50
|
Sukovich J, Xu Z, Kim Y, Cao H, Nguyen TS, Pandey A, Hall T, Cain C. Targeted Lesion Generation Through the Skull Without Aberration Correction Using Histotripsy. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:671-682. [PMID: 26890732 PMCID: PMC7371448 DOI: 10.1109/tuffc.2016.2531504] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
This study demonstrates the ability of histotripsy to generate targeted lesions through the skullcap without using aberration correction. Histotripsy therapy was delivered using a 500 kHz, 256-element hemispherical transducer with an aperture diameter of 30 cm and a focal distance of 15 cm fabricated in our lab. This transducer is theoretically capable of producing peak rarefactional pressures, based on linear estimation, (p-)LE, in the free field in excess of 200MPa with pulse durations 2 acoustic cycles. Three excised human skullcaps were used displaying attenuations of 73-81% of the acoustic pressure without aberration correction. Through all three skullcaps, compact lesions with radii less than 1mm were generated in red blood cell (RBC) agarose tissue phantoms without aberration correction, using estimated (p-)LE of 28-39MPa, a pulse repetition frequency of 1Hz, and a total number of 300 pulses. Lesion generation was consistently observed at the geometric focus of the transducer as the position of the skullcap with respect to the transducer was varied, and multiple patterned lesions were generated transcranially by mechanically adjusting the position of the skullcap with respect to the transducer to target different regions within. These results show that compact, targeted lesions with sharp boundaries can be generated through intact skullcaps using histotripsy with very short pulses without using aberration correction. Such capability has the potential to greatly simplify transcranial ultrasound therapy for non-invasive transcranial applications, as current ultrasound transcranial therapy techniques all require sophisticated aberration correction.
Collapse
|