1
|
Gu M, Pei W, Gao X, Wang Y. Optimizing the proportion of stimulation area in a grid stimulus for user-friendly SSVEP-based BCIs. J Neural Eng 2025; 22:016011. [PMID: 39808940 DOI: 10.1088/1741-2552/adaa1e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2024] [Accepted: 01/14/2025] [Indexed: 01/16/2025]
Abstract
Objective.Steady-state visual evoked potentials (SSVEPs) rely on the photic driving response to encode electroencephalogram (EEG) signals stably and efficiently. However, the user experience of the traditional stimulation with high-contrast flickers urgently needs to be improved. In this study, we introduce a novel paradigm of grid stimulation with weak flickering perception, distinguished by a markedly lower proportion of stimulation area in the overall pattern.Approach.In an offline single-target experiment, we investigated the unique characteristics of SSVEPs evoked by varying proportions in grid stimuli within low and medium frequency bands. Based on the analysis of simulation performance across a four-class brain-computer interface (BCI) task and the evaluation of user experience questionnaires, a subset of paradigms that balance performance and comfort were selected for implementation in four-target online BCI systems.Main results.Our results demonstrate that even ultra-low stimulation proportion paradigms can still evoke strong responses within specific frequency bands, effectively enhancing user experience with low and middle frequency stimuli. Notably, proportions of 0.94% and 2.10% within the 3-5 Hz range provide an optimal balance between performance and user experience. For frequencies extending up to 15 Hz, a 2.10% proportion remains ideal. At 20 Hz, slightly higher proportions of 3.75% and 8.43% maintain these benefits.Significance.These findings are crucial for advancing the development of effective and user-friendly SSVEP-based BCI systems.
Collapse
Affiliation(s)
- Meng Gu
- Key Laboratory of Solid-State Optoelectronics Information Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing, People's Republic of China
- College of Materials Science and Opto-Electronic Technology, University of Chinese Academy of Sciences, Beijing, People's Republic of China
| | - Weihua Pei
- Key Laboratory of Solid-State Optoelectronics Information Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing, People's Republic of China
- School of Future Technology, University of Chinese Academy of Sciences, Beijing, People's Republic of China
| | - Xiaorong Gao
- Department of Biomedical Engineering, Tsinghua University, Beijing, People's Republic of China
| | - Yijun Wang
- Key Laboratory of Solid-State Optoelectronics Information Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing, People's Republic of China
- School of Future Technology, University of Chinese Academy of Sciences, Beijing, People's Republic of China
- Chinese Institute for Brain Research, Beijing, People's Republic of China
| |
Collapse
|
2
|
Hamidi Shishavan H, Roy R, Golzari K, Singla A, Zalozhin D, Lohan D, Farooq M, Dede EM, Kim I. Optimization of stimulus properties for SSVEP-based BMI system with a heads-up display to control in-vehicle features. PLoS One 2024; 19:e0308506. [PMID: 39288164 PMCID: PMC11407624 DOI: 10.1371/journal.pone.0308506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Accepted: 07/24/2024] [Indexed: 09/19/2024] Open
Abstract
Over the years, the driver-vehicle interface has been improved, but interacting with in-vehicle features can still increase distraction and affect road safety. This study aims to introduce brain-machine interface (BMI)- based solution to potentially enhance road safety. To achieve this goal, we evaluated visual stimuli properties (SPs) for a steady state visually evoked potentials (SSVEP)-based BMI system. We used a heads-up display (HUD) as the primary screen to present icons for controlling in-vehicle functions such as music, temperature, settings, and navigation. We investigated the effect of various SPs on SSVEP detection performance including the duty cycle and signal-to-noise ratio of visual stimuli, the size, color, and frequency of the icons, and array configuration and location. The experiments were conducted with 10 volunteers and the signals were analyzed using the canonical correlation analysis (CCA), filter bank CCA (FBCCA), and power spectral density analysis (PSDA). Our experimental results suggest that stimuli with a green color, a duty cycle of 50%, presented at a central location, with a size of 36 cm2 elicit a significantly stronger SSVEP response and enhanced SSVEP detection time. We also observed that lower SNR stimuli significantly affect SSVEP detection performance. There was no statistically significant difference observed in SSVEP response between the use of an LCD monitor and a HUD.
Collapse
Affiliation(s)
- Hossein Hamidi Shishavan
- Department of Medicine, University of Connecticut School of Medicine, Farmington, Connecticut, United States of America
- Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut, United States of America
| | - Raheli Roy
- Department of Medicine, University of Connecticut School of Medicine, Farmington, Connecticut, United States of America
- Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut, United States of America
| | - Kia Golzari
- Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut, United States of America
| | - Abhishek Singla
- Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut, United States of America
| | - David Zalozhin
- Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut, United States of America
| | - Danny Lohan
- Toyota Research Institute of North America, Ann Arbor, Michigan, United States of America
| | - Muhamed Farooq
- Toyota Research Institute of North America, Ann Arbor, Michigan, United States of America
| | - Ercan M Dede
- Toyota Research Institute of North America, Ann Arbor, Michigan, United States of America
| | - Insoo Kim
- Department of Medicine, University of Connecticut School of Medicine, Farmington, Connecticut, United States of America
- Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut, United States of America
| |
Collapse
|
3
|
Gu M, Pei W, Gao X, Wang Y. Optimizing Visual Stimulation Paradigms for User-Friendly SSVEP-Based BCIs. IEEE Trans Neural Syst Rehabil Eng 2024; 32:1090-1099. [PMID: 38437148 DOI: 10.1109/tnsre.2024.3372594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/06/2024]
Abstract
In steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) systems, traditional flickering stimulation patterns face challenges in achieving a trade-off in both BCI performance and visual comfort across various frequency bands. To investigate the optimal stimulation paradigms with high performance and high comfort for each frequency band, this study systematically compared the characteristics of SSVEP and user experience of different stimulation paradigms with a wide stimulation frequency range of 1-60 Hz. The findings suggest that, for a better balance between system performance and user experience, ON and OFF grid stimuli with a Weber contrast of 50% can be utilized as alternatives to traditional flickering stimulation paradigms in the frequency band of 1-25 Hz. In the 25-35 Hz range, uniform flicker stimuli with the same 50% contrast are more suitable. In the higher frequency band, traditional uniform flicker stimuli with a high 300% contrast are preferred. These results are significant for developing high performance and user-friendly SSVEP-based BCI systems.
Collapse
|
4
|
Gao S, Zhou K, Zhang J, Cheng Y, Mao S. Effects of Background Music on Mental Fatigue in Steady-State Visually Evoked Potential-Based BCIs. Healthcare (Basel) 2023; 11:healthcare11071014. [PMID: 37046941 PMCID: PMC10094051 DOI: 10.3390/healthcare11071014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Revised: 03/28/2023] [Accepted: 03/31/2023] [Indexed: 04/05/2023] Open
Abstract
As a widely used brain–computer interface (BCI) paradigm, steady-state visually evoked potential (SSVEP)-based BCIs have the advantages of high information transfer rates, high tolerance for artifacts, and robust performance across diverse users. However, the incidence of mental fatigue from prolonged, repetitive stimulation is a critical issue for SSVEP-based BCIs. Music is often used as a convenient, non-invasive means of relieving mental fatigue. This study investigates the compensatory effect of music on mental fatigue through the introduction of different modes of background music in long-duration, SSVEP-BCI tasks. Changes in electroencephalography power index, SSVEP amplitude, and signal-to-noise ratio were used to assess participants’ mental fatigue. The study’s results show that the introduction of exciting background music to the SSVEP-BCI task was effective in relieving participants’ mental fatigue. In addition, for continuous SSVEP-BCI tasks, a combination of musical modes that used soothing background music during the rest interval phase proved more effective in reducing users’ mental fatigue. This suggests that background music can provide a practical solution for long-duration SSVEP-based BCI implementation.
Collapse
Affiliation(s)
- Shouwei Gao
- School of Mechanical and Electrical Engineering and Automation, Shanghai University, Shanghai 200444, China
| | - Kang Zhou
- School of Mechanical and Electrical Engineering and Automation, Shanghai University, Shanghai 200444, China
| | - Jun Zhang
- School of Mechanical and Electrical Engineering and Automation, Shanghai University, Shanghai 200444, China
| | - Yi Cheng
- School of Mechanical and Electrical Engineering and Automation, Shanghai University, Shanghai 200444, China
| | - Shujun Mao
- School of Mechanical and Electrical Engineering and Automation, Shanghai University, Shanghai 200444, China
| |
Collapse
|
5
|
Ming G, Zhong H, Pei W, Gao X, Wang Y. A new grid stimulus with subtle flicker perception for user-friendly SSVEP-based BCIs. J Neural Eng 2023; 20. [PMID: 36827704 DOI: 10.1088/1741-2552/acbee0] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Accepted: 02/24/2023] [Indexed: 02/26/2023]
Abstract
Objective.The traditional uniform flickering stimulation pattern shows strong steady-state visual evoked potential (SSVEP) responses and poor user experience with intense flicker perception. To achieve a balance between performance and comfort in SSVEP-based brain-computer interface (BCI) systems, this study proposed a new grid stimulation pattern with reduced stimulation area and low spatial contrast.Approach.A spatial contrast scanning experiment was conducted first to clarify the relationship between the SSVEP characteristics and the signs and values of spatial contrast. Four stimulation patterns were involved in the experiment: the ON and OFF grid stimulation patterns that separately activated the positive or negative contrast information processing pathways, the ON-OFF grid stimulation pattern that simultaneously activated both pathways, and the uniform flickering stimulation pattern that served as a control group. The contrast-intensity and contrast-user experience curves were obtained for each stimulation pattern. Accordingly, the optimized stimulation schemes with low spatial contrast (the ON-50% grid stimulus, the OFF-50% grid stimulus, and the Flicker-30% stimulus) were applied in a 12-target and a 40-target BCI speller and compared with the traditional uniform flickering stimulus (the Flicker-500% stimulus) in the evaluation of BCI performance and subjective experience.Main results.The OFF-50% grid stimulus showed comparable online performance (12-target, 2 s: 69.87 ± 0.74 vs. 69.76 ± 0.58 bits min-1, 40-target, 4 s: 57.02 ± 2.53 vs. 60.79 ± 1.08 bits min-1) and improved user experience (better comfortable level, weaker flicker perception and higher preference level) compared to the traditional Flicker-500% stimulus in both multi-targets BCI spellers.Significance.Selective activation of the negative contrast information processing pathway using the new OFF-50% grid stimulus evoked robust SSVEP responses. On this basis, high-performance and user-friendly SSVEP-based BCIs have been developed and implemented, which has important theoretical significance and application value in promoting the development of the visual BCI technology.
Collapse
Affiliation(s)
- Gege Ming
- State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, People's Republic of China.,School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
| | - Hui Zhong
- Jiangsu JITRI Brian Machine Fusion Intelligence Institute, Suzhou 215008, People's Republic of China
| | - Weihua Pei
- State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, People's Republic of China.,School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
| | - Xiaorong Gao
- Department of Biomedical Engineering, Tsinghua University, Beijing 100084, People's Republic of China
| | - Yijun Wang
- State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, People's Republic of China.,School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China.,Chinese Institute for Brain Research, Beijing 102206, People's Republic of China
| |
Collapse
|
6
|
Lee PL, Lee TM, Lee WK, Chu NN, Shelepin YE, Hsu HT, Chang HH. The Full Informational Spectral Analysis for Auditory Steady-State Responses in Human Brain Using the Combination of Canonical Correlation Analysis and Holo-Hilbert Spectral Analysis. J Clin Med 2022; 11:jcm11133868. [PMID: 35807153 PMCID: PMC9267805 DOI: 10.3390/jcm11133868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 06/19/2022] [Accepted: 06/24/2022] [Indexed: 11/17/2022] Open
Abstract
Auditory steady-state response (ASSR) is a translational biomarker for several neurological and psychiatric disorders, such as hearing loss, schizophrenia, bipolar disorder, autism, etc. The ASSR is sinusoidal electroencephalography (EEG)/magnetoencephalography (MEG) responses induced by periodically presented auditory stimuli. Traditional frequency analysis assumes ASSR is a stationary response, which can be analyzed using linear analysis approaches, such as Fourier analysis or Wavelet. However, recent studies have reported that the human steady-state responses are dynamic and can be modulated by the subject’s attention, wakefulness state, mental load, and mental fatigue. The amplitude modulations on the measured oscillatory responses can result in the spectral broadening or frequency splitting on the Fourier spectrum, owing to the trigonometric product-to-sum formula. Accordingly, in this study, we analyzed the human ASSR by the combination of canonical correlation analysis (CCA) and Holo-Hilbert spectral analysis (HHSA). The CCA was used to extract ASSR-related signal features, and the HHSA was used to decompose the extracted ASSR responses into amplitude modulation (AM) components and frequency modulation (FM) components, in which the FM frequency represents the fast-changing intra-mode frequency and the AM frequency represents the slow-changing inter-mode frequency. In this paper, we aimed to study the AM and FM spectra of ASSR responses in a 37 Hz steady-state auditory stimulation. Twenty-five healthy subjects were recruited for this study, and each subject was requested to participate in two auditory stimulation sessions, including one right-ear and one left-ear monaural steady-state auditory stimulation. With the HHSA, both the 37 Hz (fundamental frequency) and the 74 Hz (first harmonic frequency) auditory responses were successfully extracted. Examining the AM spectra, the 37 Hz and the 74 Hz auditory responses were modulated by distinct AM spectra, each with at least three composite frequencies. In contrast to the results of traditional Fourier spectra, frequency splitting was seen at 37 Hz, and a spectral peak was obscured at 74 Hz in Fourier spectra. The proposed method effectively corrects the frequency splitting problem resulting from time-varying amplitude changes. Our results have validated the HHSA as a useful tool for steady-state response (SSR) studies so that the misleading or wrong interpretation caused by amplitude modulation in the traditional Fourier spectrum can be avoided.
Collapse
Affiliation(s)
- Po-Lei Lee
- Department of Electrical Engineering, National Central University, Taoyuan 320, Taiwan; (T.-M.L.); (H.-T.H.)
- Correspondence: (P.-L.L.); (H.-H.C.)
| | - Te-Min Lee
- Department of Electrical Engineering, National Central University, Taoyuan 320, Taiwan; (T.-M.L.); (H.-T.H.)
| | - Wei-Keung Lee
- Department of Rehabilitation, Taoyuan General Hospital, Taoyuan 330, Taiwan;
| | | | - Yuri E. Shelepin
- The Pavlov Institute of Physiology, Russian Academy of Sciences, 199034 St. Petersburg, Russia;
| | - Hao-Teng Hsu
- Department of Electrical Engineering, National Central University, Taoyuan 320, Taiwan; (T.-M.L.); (H.-T.H.)
| | - Hsiao-Huang Chang
- Division of Cardiovascular Surgery, Taipei Veterans General Hospital, Taipei 112, Taiwan
- Department of Surgery, School of Medicine, Taipei Medical University, Taipei 106, Taiwan
- Correspondence: (P.-L.L.); (H.-H.C.)
| |
Collapse
|
7
|
Shirzhiyan Z, Keihani A, Farahi M, Shamsi E, GolMohammadi M, Mahnam A, Haidari MR, Jafari AH. Toward New Modalities in VEP-Based BCI Applications Using Dynamical Stimuli: Introducing Quasi-Periodic and Chaotic VEP-Based BCI. Front Neurosci 2020; 14:534619. [PMID: 33328841 PMCID: PMC7718037 DOI: 10.3389/fnins.2020.534619] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2020] [Accepted: 09/15/2020] [Indexed: 11/13/2022] Open
Abstract
Visual evoked potentials (VEPs) to periodic stimuli are commonly used in brain computer interfaces for their favorable properties such as high target identification accuracy, less training time, and low surrounding target interference. Conventional periodic stimuli can lead to subjective visual fatigue due to continuous and high contrast stimulation. In this study, we compared quasi-periodic and chaotic complex stimuli to common periodic stimuli for use with VEP-based brain computer interfaces (BCIs). Canonical correlation analysis (CCA) and coherence methods were used to evaluate the performance of the three stimulus groups. Subjective fatigue caused by the presented stimuli was evaluated by the Visual Analogue Scale (VAS). Using CCA with the M2 template approach, target identification accuracy was highest for the chaotic stimuli (M = 86.8, SE = 1.8) compared to the quasi-periodic (M = 78.1, SE = 2.6, p = 0.008) and periodic (M = 64.3, SE = 1.9, p = 0.0001) stimulus groups. The evaluation of fatigue rates revealed that the chaotic stimuli caused less fatigue compared to the quasi-periodic (p = 0.001) and periodic (p = 0.0001) stimulus groups. In addition, the quasi-periodic stimuli led to lower fatigue rates compared to the periodic stimuli (p = 0.011). We conclude that the target identification results were better for the chaotic group compared to the other two stimulus groups with CCA. In addition, the chaotic stimuli led to a less subjective visual fatigue compared to the periodic and quasi-periodic stimuli and can be suitable for designing new comfortable VEP-based BCIs.
Collapse
Affiliation(s)
- Zahra Shirzhiyan
- Computational Neuroscience, Institute of Medical Technology, Brandenburg University of Technology Cottbus-Senftenberg, Cottbus, Germany.,Department of Medical Physics & Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.,Research Center for Biomedical Technologies and Robotics (RCBTR), Tehran University of Medical Sciences, Tehran, Iran
| | - Ahmadreza Keihani
- Department of Medical Physics & Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.,Research Center for Biomedical Technologies and Robotics (RCBTR), Tehran University of Medical Sciences, Tehran, Iran
| | - Morteza Farahi
- Department of Medical Physics & Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.,Research Center for Biomedical Technologies and Robotics (RCBTR), Tehran University of Medical Sciences, Tehran, Iran
| | - Elham Shamsi
- Department of Medical Physics & Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Mina GolMohammadi
- Research Center for Biomedical Technologies and Robotics (RCBTR), Tehran University of Medical Sciences, Tehran, Iran
| | - Amin Mahnam
- Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran
| | - Mohsen Reza Haidari
- Section of Neuroscience, Department of Neurology, Faculty of Medicine, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Amir Homayoun Jafari
- Department of Medical Physics & Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.,Research Center for Biomedical Technologies and Robotics (RCBTR), Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
8
|
Zhang X, Li H, Chen F. EEG-based Classification of Imaginary Mandarin Tones. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:3889-3892. [PMID: 33018850 DOI: 10.1109/embc44109.2020.9176608] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Speech imagery based brain-computer interface (BCI) has the potential to assist patients with communication disorders to recover their speech communication abilities. Mandarin is a tonal language, and its tones play an important role in language perception and semantic understanding. This work studied the electroencephalogram (EEG) based classification of Mandarin tones based on speech imagery, and also compared the classification performance of speech imagery based BCIs at two test conditions with visual-only and combined audio-visual stimuli, respectively. Participants imagined 4 Mandarin tones at each condition. Common spatial patterns were applied to extract feature vectors, and support vector machine was used to classify different Mandarin tones from EEG data. Experimental results showed that the tonal articulation imagination task achieved a higher classification accuracy at the combined audio-visual condition (i.e., 80.1%) than at the visual-only condition (i.e., 67.7%). The results in this work supported that Mandarin tone information could be decoded from EEG data recorded in a speech imagery task, particularly under the combined audio-visual condition.
Collapse
|
9
|
A comprehensive assessment of Brain Computer Interfaces: Recent trends and challenges. J Neurosci Methods 2020; 346:108918. [PMID: 32853592 DOI: 10.1016/j.jneumeth.2020.108918] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Revised: 07/15/2020] [Accepted: 08/19/2020] [Indexed: 12/23/2022]
Abstract
BACKGROUND An uninterrupted channel of communication and control between the human brain and electronic processing units has led to an increased use of Brain Computer Interfaces (BCIs). This article attempts to present an all-encompassing review on BCI and the scientific advancements associated with it. The ultimate goal of this review is to provide a general overview of the BCI technology and to shed light on different aspects of BCIs. This review also underscores the applications, practical challenges and opportunities associated with BCI technology, which can be used to accelerate future developments in this field. METHODS This review is based on a systematic literature search for tracking down the relevant research annals and proceedings. Using a methodical search strategy, the search was carried out across major technical databases. The retrieved records were screened for their relevance and a total of 369 research chronicles were engulfed in this review based on the inclusion criteria. RESULTS This review describes the present scenario and recent advancements in BCI technology. It also identifies several application areas of BCI technology. This comprehensive review provides evidence that, while we are getting ever closer, significant challenges still exist for the development of BCIs that can seamlessly integrate with the user's biological system. CONCLUSION The findings of this review confirm the importance of BCI technology in various applications. It is concluded that BCI technology, still in its sprouting phase, requires significant explorations for further development.
Collapse
|
10
|
Mannan MMN, Kamran MA, Kang S, Choi HS, Jeong MY. A Hybrid Speller Design Using Eye Tracking and SSVEP Brain-Computer Interface. SENSORS 2020; 20:s20030891. [PMID: 32046131 PMCID: PMC7039291 DOI: 10.3390/s20030891] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2019] [Revised: 01/27/2020] [Accepted: 02/05/2020] [Indexed: 12/14/2022]
Abstract
Steady-state visual evoked potentials (SSVEPs) have been extensively utilized to develop brain-computer interfaces (BCIs) due to the advantages of robustness, large number of commands, high classification accuracies, and information transfer rates (ITRs). However, the use of several simultaneous flickering stimuli often causes high levels of user discomfort, tiredness, annoyingness, and fatigue. Here we propose to design a stimuli-responsive hybrid speller by using electroencephalography (EEG) and video-based eye-tracking to increase user comfortability levels when presented with large numbers of simultaneously flickering stimuli. Interestingly, a canonical correlation analysis (CCA)-based framework was useful to identify target frequency with a 1 s duration of flickering signal. Our proposed BCI-speller uses only six frequencies to classify forty-eight targets, thus achieve greatly increased ITR, whereas basic SSVEP BCI-spellers use an equal number of frequencies to the number of targets. Using this speller, we obtained an average classification accuracy of 90.35 ± 3.597% with an average ITR of 184.06 ± 12.761 bits per minute in a cued-spelling task and an ITR of 190.73 ± 17.849 bits per minute in a free-spelling task. Consequently, our proposed speller is superior to the other spellers in terms of targets classified, classification accuracy, and ITR, while producing less fatigue, annoyingness, tiredness and discomfort. Together, our proposed hybrid eye tracking and SSVEP BCI-based system will ultimately enable a truly high-speed communication channel.
Collapse
Affiliation(s)
- Malik M. Naeem Mannan
- Department of Cogno-Mechatronics Engineering, Pusan National University, 2 Busandaehak-ro, 63 Beon-gil, Geumjeong-gu, Busan 609-735, Korea; (M.M.N.M.); (M.A.K.); (H.S.C.)
| | - M. Ahmad Kamran
- Department of Cogno-Mechatronics Engineering, Pusan National University, 2 Busandaehak-ro, 63 Beon-gil, Geumjeong-gu, Busan 609-735, Korea; (M.M.N.M.); (M.A.K.); (H.S.C.)
| | - Shinil Kang
- National Center for Optically-Assisted Ultrahigh-Precision Mechanical Systems, Yonsei University, Seoul 03722, Korea;
- School of Mechanical Engineering, Yonsei University, Seoul 03722, Korea
| | - Hak Soo Choi
- Department of Cogno-Mechatronics Engineering, Pusan National University, 2 Busandaehak-ro, 63 Beon-gil, Geumjeong-gu, Busan 609-735, Korea; (M.M.N.M.); (M.A.K.); (H.S.C.)
- Division of Hematology/Oncology, Department of Medicine, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA 02115, USA
| | - Myung Yung Jeong
- Department of Cogno-Mechatronics Engineering, Pusan National University, 2 Busandaehak-ro, 63 Beon-gil, Geumjeong-gu, Busan 609-735, Korea; (M.M.N.M.); (M.A.K.); (H.S.C.)
- Correspondence:
| |
Collapse
|
11
|
EEG-Controlled Wall-Crawling Cleaning Robot Using SSVEP-Based Brain-Computer Interface. JOURNAL OF HEALTHCARE ENGINEERING 2020; 2020:6968713. [PMID: 32399166 PMCID: PMC7201509 DOI: 10.1155/2020/6968713] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/13/2019] [Revised: 10/29/2019] [Accepted: 11/29/2019] [Indexed: 01/24/2023]
Abstract
The assistive, adaptive, and rehabilitative applications of EEG-based robot control and navigation are undergoing a major transformation in dimension as well as scope. Under the background of artificial intelligence, medical and nonmedical robots have rapidly developed and have gradually been applied to enhance the quality of people's lives. We focus on connecting the brain with a mobile home robot by translating brain signals to computer commands to build a brain-computer interface that may offer the promise of greatly enhancing the quality of life of disabled and able-bodied people by considerably improving their autonomy, mobility, and abilities. Several types of robots have been controlled using BCI systems to complete real-time simple and/or complicated tasks with high performances. In this paper, a new EEG-based intelligent teleoperation system was designed for a mobile wall-crawling cleaning robot. This robot uses crawler type instead of the traditional wheel type to be used for window or floor cleaning. For EEG-based system controlling the robot position to climb the wall and complete the tasks of cleaning, we extracted steady state visually evoked potential (SSVEP) from the collected electroencephalography (EEG) signal. The visual stimulation interface in the proposed SSVEP-based BCI was composed of four flicker pieces with different frequencies (e.g., 6 Hz, 7.5 Hz, 8.57 Hz, and 10 Hz). Seven subjects were able to smoothly control the movement directions of the cleaning robot by looking at the corresponding flicker using their brain activity. To solve the multiclass problem, thereby achieving the purpose of cleaning the wall within a short period, the canonical correlation analysis (CCA) classification algorithm had been used. Offline and online experiments were held to analyze/classify EEG signals and use them as real-time commands. The proposed system was efficient in the classification and control phases with an obtained accuracy of 89.92% and had an efficient response speed and timing with a bit rate of 22.23 bits/min. These results suggested that the proposed EEG-based clean robot system is promising for smart home control in terms of completing the tasks of cleaning the walls with efficiency, safety, and robustness.
Collapse
|
12
|
Kim J, Lee J, Han C, Park K. An Instant Donning Multi-Channel EEG Headset (with Comb-Shaped Dry Electrodes) and BCI Applications. SENSORS (BASEL, SWITZERLAND) 2019; 19:E1537. [PMID: 30934931 PMCID: PMC6479764 DOI: 10.3390/s19071537] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/27/2019] [Revised: 03/23/2019] [Accepted: 03/27/2019] [Indexed: 12/03/2022]
Abstract
We developed a new type of electroencephalogram (EEG) headset system with comb-shaped electrodes that enables the wearer to quickly don and utilize it in daily life. Two models that can measure EEG signals using up to eight channels have been implemented. The electrodes implemented in the headsets are similar to a comb and are placed quickly by wiping the hair (as done with a comb) using the headset. To verify this headset system, donning time was measured and three brain computer interface (BCI) application experiments were conducted. Alpha rhythm-based, steady-state visual evoked potential (SSVEP)-based, and auditory steady state response (ASSR)-based BCI systems were adopted for the validation experiments. Four subjects participated and ten trials were repeated in the donning experiment. The results of the validation experiments show that reliable EEG signal measurement is possible immediately after donning the headsets without any preparation. It took approximately 10 s for healthy subjects to don the headsets, including an earclip with reference and ground electrodes. The results of alpha rhythm-based BCI showed 100% accuracy. Furthermore, the results of SSVEP-based and ASSR-based BCI experiments indicate that performance is sufficient for BCI applications; 95.7% and 76.0% accuracies were obtained, respectively. The results of BCI paradigm experiments indicate that the new headset type is feasible for various BCI applications.
Collapse
Affiliation(s)
- Jeehoon Kim
- Interdisciplinary Program of Bioengineering, Seoul National University, Seoul 03080, Korea.
| | - Jeongsu Lee
- Mobile Communication Business, Samsung Electronics Co. Ltd.; 130 Samsung-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do 16678, Korea.
| | - Chungmin Han
- Department of Biomedical Engineering, University of Texas at Austin, Austin, TX 78712, USA.
| | - Kwangsuk Park
- Interdisciplinary Program of Bioengineering, Seoul National University, Seoul 03080, Korea.
- Department of Biomedical Engineering, College of Medicine, Seoul National University, Seoul 03080, Korea.
| |
Collapse
|
13
|
Benda M, Stawicki P, Gembler F, Grichnik R, Rezeika A, Saboor A, Volosyak I. Different Feedback Methods For An SSVEP-Based BCI. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:1939-1943. [PMID: 30440778 DOI: 10.1109/embc.2018.8512622] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
In this paper we examined different ways to inform the user of the classification progress in our online SSVEPbased BCI speller. Different user feedback was given based on the distance from the classification threshold, separately calculated for each stimulus. We focused on the comparison of the accuracies and spelling times associated with each different feedback type. We tested eight different methods, one without feedback for comparison, and the two paradigms each (an increase and a decrease), for three varying parameters, during an online spelling task. The eighth method was a combination of the best performing feedback modalities. A 28 target speller was used for spelling the same word with different feedback methods. The level of comfort was assessed by the seven healthy participants, using a questionnaire. We found substantial decreases in spelling times; they were reduced to 12-77% of the no-feedback condition spelling times, for each of our subjects, with at least one of the parameters. However, this parameter, as expected, was different for each user. According to the personal fastest feedback methods, a combination of them was also used for spelling. These combined feedback methods usually resulted in a slower spelling than the individual best feedback, but still faster than without any feedback. Overall, the average spelling times with the different feedback methods were: no feedback, 95.09 s, increasing size, 62.94 s, decreasing size, 87.73 s, increasing contrast, 77.80 s, decreasing contrast, 124.37 s, increasing duty-cycle, 134.70 s, and decreasing dutycycle, 103.77 s.
Collapse
|
14
|
Ajami S, Mahnam A, Abootalebi V. An Adaptive SSVEP-Based Brain-Computer Interface to Compensate Fatigue-Induced Decline of Performance in Practical Application. IEEE Trans Neural Syst Rehabil Eng 2018; 26:2200-2209. [PMID: 30307871 DOI: 10.1109/tnsre.2018.2874975] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Brain-computer interfaces based on steady-state visual evoked potentials are promising communication systems for people with speech and motor disabilities. However, reliable SSVEP response requires user's attention, which degrades over time due to significant eye-fatigue when low-frequency visual stimuli (5-15 Hz) are used. Previous studies have shown that eye-fatigue can be reduced using high-frequency flickering stimuli (>25 Hz). Here, it is quantitatively demonstrated that the performance of a high-frequency SSVEP BCI decreases over time, but this amount of decrease can be compensated effectively by using two proposed adaptive algorithms. This leaded to a robust alternative communication system for practical applications. The asynchronous spelling system implemented in this study uses a threshold-based version of LASSO algorithm for frequency recognition. In long online experiments, when participants typed a sentence with the BCI system for 16 times, accuracy of the system was close to its maximum along the experiment. However, regression analysis on typing speed of each sentence demonstrated a significant decrease in all 7 subjects ( ) when thresholds obtained from a calibration test were kept fixed over the experiment. In comparison, no significant change in typing speed was observed when the proposed adaptive algorithms were used. The analysis of variances revealed that the average typing speed of the last four sentences when using adaptive relational algorithm (8.7 char/min) was significantly higher than the tolerance-based algorithm (8.1 char/min) and significantly above 6 char/min when the fixed thresholds were used. Therefore, the relational algorithm proposed in this paper could successfully compensate for the effect of fatigue on performance of the SSVEP BCI system.
Collapse
|
15
|
Olze K, Jan Wehrmann C, Mu L, Schilling M. Obstacles in using a computer screen for steady-state visually evoked potential stimulation. BIOMED ENG-BIOMED TE 2018; 63:377-382. [PMID: 29185990 DOI: 10.1515/bmt-2016-0243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Accepted: 04/20/2017] [Indexed: 11/15/2022]
Abstract
In brain computer interface (BCI) applications, the use of steady-state visually evoked potentials (SSVEPs) is common. Therefore, a visual stimulation with a constant repetition frequency is necessary. However, using a computer monitor, the set of frequencies that can be used is restricted by the refresh rate of the screen. Frequencies that are not an integer divisor of the refresh rate cannot be displayed correctly. Furthermore, the programming language the stimulation software is written in and the operating system influence the actually generated and presented frequencies. The aim of this paper is to identify the main challenges in generating SSVEP stimulation using a computer screen with and without using DirectX in Windows-based PC systems and to provide solutions for these issues.
Collapse
Affiliation(s)
- Katharina Olze
- Institut für Elektrische Messtechnik und Grundlagen der Elektrotechnik (EMG), TU Braunschweig, Hans-Sommer-Str. 66, 38106 Braunschweig, Germany, Phone: +49 531 391 3851
| | | | - Luyang Mu
- EMG, TU Braunschweig, Hans-Sommer-Str. 66, 38106 Braunschweig, Germany
| | | |
Collapse
|
16
|
|
17
|
Maximizing Information Transfer in SSVEP-Based Brain–Computer Interfaces. IEEE Trans Biomed Eng 2017; 64:381-394. [DOI: 10.1109/tbme.2016.2559527] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
18
|
|
19
|
Wan F, da Cruz JN, Nan W, Wong CM, Vai MI, Rosa A. Alpha neurofeedback training improves SSVEP-based BCI performance. J Neural Eng 2016; 13:036019. [PMID: 27152666 DOI: 10.1088/1741-2560/13/3/036019] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
OBJECTIVE Steady-state visual evoked potential (SSVEP)-based brain-computer interfaces (BCIs) can provide relatively easy, reliable and high speed communication. However, the performance is still not satisfactory, especially in some users who are not able to generate strong enough SSVEP signals. This work aims to strengthen a user's SSVEP by alpha down-regulating neurofeedback training (NFT) and consequently improve the performance of the user in using SSVEP-based BCIs. APPROACH An experiment with two steps was designed and conducted. The first step was to investigate the relationship between the resting alpha activity and the SSVEP-based BCI performance, in order to determine the training parameter for the NFT. Then in the second step, half of the subjects with 'low' performance (i.e. BCI classification accuracy <80%) were randomly assigned to a NFT group to perform a real-time NFT, and the rest half to a non-NFT control group for comparison. MAIN RESULTS The first step revealed a significant negative correlation between the BCI performance and the individual alpha band (IAB) amplitudes in the eyes-open resting condition in a total of 33 subjects. In the second step, it was found that during the IAB down-regulating NFT, on average the subjects were able to successfully decrease their IAB amplitude over training sessions. More importantly, the NFT group showed an average increase of 16.5% in the SSVEP signal SNR (signal-to-noise ratio) and an average increase of 20.3% in the BCI classification accuracy, which was significant compared to the non-NFT control group. SIGNIFICANCE These findings indicate that the alpha down-regulating NFT can be used to improve the SSVEP signal quality and the subjects' performance in using SSVEP-based BCIs. It could be helpful to the SSVEP related studies and would contribute to more effective SSVEP-based BCI applications.
Collapse
Affiliation(s)
- Feng Wan
- Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau, People's Republic of China
| | | | | | | | | | | |
Collapse
|
20
|
A Prototype SSVEP Based Real Time BCI Gaming System. COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE 2016; 2016:3861425. [PMID: 27051414 PMCID: PMC4804071 DOI: 10.1155/2016/3861425] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/15/2015] [Revised: 01/06/2016] [Accepted: 01/10/2016] [Indexed: 11/17/2022]
Abstract
Although brain-computer interface technology is mainly designed with disabled people in mind, it can also be beneficial to healthy subjects, for example, in gaming or virtual reality systems. In this paper we discuss the typical architecture, paradigms, requirements, and limitations of electroencephalogram-based gaming systems. We have developed a prototype three-class brain-computer interface system, based on the steady state visually evoked potentials paradigm and the Emotiv EPOC headset. An online target shooting game, implemented in the OpenViBE environment, has been used for user feedback. The system utilizes wave atom transform for feature extraction, achieving an average accuracy of 78.2% using linear discriminant analysis classifier, 79.3% using support vector machine classifier with a linear kernel, and 80.5% using a support vector machine classifier with a radial basis function kernel.
Collapse
|
21
|
Lee YC, Lin WC, Cherng FY, Ko LW. A Visual Attention Monitor Based on Steady-State Visual Evoked Potential. IEEE Trans Neural Syst Rehabil Eng 2016; 24:399-408. [DOI: 10.1109/tnsre.2015.2501378] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
22
|
Won DO, Hwang HJ, Dähne S, Müller KR, Lee SW. Effect of higher frequency on the classification of steady-state visual evoked potentials. J Neural Eng 2015; 13:016014. [DOI: 10.1088/1741-2560/13/1/016014] [Citation(s) in RCA: 83] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
23
|
Waytowich NR, Krusienski DJ. Spatial decoupling of targets and flashing stimuli for visual brain-computer interfaces. J Neural Eng 2015; 12:036006. [PMID: 25875047 DOI: 10.1088/1741-2560/12/3/036006] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Recently, paradigms using code-modulated visual evoked potentials (c-VEPs) have proven to achieve among the highest information transfer rates for noninvasive brain-computer interfaces (BCIs). One issue with current c-VEP paradigms, and visual-evoked paradigms in general, is that they require direct foveal fixation of the flashing stimuli. These interfaces are often visually unpleasant and can be irritating and fatiguing to the user, thus adversely impacting practical performance. In this study, a novel c-VEP BCI paradigm is presented that attempts to perform spatial decoupling of the targets and flashing stimuli using two distinct concepts: spatial separation and boundary positioning. APPROACH For the paradigm, the flashing stimuli form a ring that encompasses the intended non-flashing targets, which are spatially separated from the stimuli. The user fixates on the desired target, which is classified using the changes to the EEG induced by the flashing stimuli located in the non-foveal visual field. Additionally, a subset of targets is also positioned at or near the stimulus boundaries, which decouples targets from direct association with a single stimulus. This allows a greater number of target locations for a fixed number of flashing stimuli. MAIN RESULTS Results from 11 subjects showed practical classification accuracies for the non-foveal condition, with comparable performance to the direct-foveal condition for longer observation lengths. Online results from 5 subjects confirmed the offline results with an average accuracy across subjects of 95.6% for a 4-target condition. The offline analysis also indicated that targets positioned at or near the boundaries of two stimuli could be classified with the same accuracy as traditional superimposed (non-boundary) targets. SIGNIFICANCE The implications of this research are that c-VEPs can be detected and accurately classified to achieve comparable BCI performance without requiring potentially irritating direct foveation of flashing stimuli. Furthermore, this study shows that it is possible to increase the number of targets beyond the number of stimuli without degrading performance. Given the superior information transfer rate of c-VEP paradigms, these results can lead to the development of more practical and ergonomic BCIs.
Collapse
|
24
|
A Configurable, Inexpensive, Portable, Multi-channel, Multi-frequency, Multi-chromatic RGB LED System for SSVEP Stimulation. BRAIN-COMPUTER INTERFACES 2015. [DOI: 10.1007/978-3-319-10978-7_9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
25
|
An amplitude-modulated visual stimulation for reducing eye fatigue in SSVEP-based brain–computer interfaces. Clin Neurophysiol 2014; 125:1380-91. [DOI: 10.1016/j.clinph.2013.11.016] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2013] [Revised: 09/13/2013] [Accepted: 11/16/2013] [Indexed: 11/21/2022]
|
26
|
Nakanishi M, Wang Y, Wang YT, Mitsukura Y, Jung TP. A high-speed brain speller using steady-state visual evoked potentials. Int J Neural Syst 2014; 24:1450019. [PMID: 25081427 DOI: 10.1142/s0129065714500191] [Citation(s) in RCA: 205] [Impact Index Per Article: 18.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Implementing a complex spelling program using a steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) remains a challenge due to difficulties in stimulus presentation and target identification. This study aims to explore the feasibility of mixed frequency and phase coding in building a high-speed SSVEP speller with a computer monitor. A frequency and phase approximation approach was developed to eliminate the limitation of the number of targets caused by the monitor refresh rate, resulting in a speller comprising 32 flickers specified by eight frequencies (8-15 Hz with a 1 Hz interval) and four phases (0°, 90°, 180°, and 270°). A multi-channel approach incorporating Canonical Correlation Analysis (CCA) and SSVEP training data was proposed for target identification. In a simulated online experiment, at a spelling rate of 40 characters per minute, the system obtained an averaged information transfer rate (ITR) of 166.91 bits/min across 13 subjects with a maximum individual ITR of 192.26 bits/min, the highest ITR ever reported in electroencephalogram (EEG)-based BCIs. The results of this study demonstrate great potential of a high-speed SSVEP-based BCI in real-life applications.
Collapse
Affiliation(s)
- Masaki Nakanishi
- Graduate School of Science and Technology, Keio University, Yokohama, Kanagawa, 223-8522, Japan
| | | | | | | | | |
Collapse
|
27
|
|
28
|
Cao T, Wan F, Wong CM, da Cruz JN, Hu Y. Objective evaluation of fatigue by EEG spectral analysis in steady-state visual evoked potential-based brain-computer interfaces. Biomed Eng Online 2014; 13:28. [PMID: 24621009 PMCID: PMC3995691 DOI: 10.1186/1475-925x-13-28] [Citation(s) in RCA: 91] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2013] [Accepted: 03/05/2014] [Indexed: 11/22/2022] Open
Abstract
Background The fatigue that users suffer when using steady-state visual evoked potential (SSVEP)-based brain-computer interfaces (BCIs) can cause a number of serious problems such as signal quality degradation and system performance deterioration, users’ discomfort and even risk of photosensitive epileptic seizures, posing heavy restrictions on the applications of SSVEP-based BCIs. Towards alleviating the fatigue, a fundamental step is to measure and evaluate it but most existing works adopt self-reported questionnaire methods which are subjective, offline and memory dependent. This paper proposes an objective and real-time approach based on electroencephalography (EEG) spectral analysis to evaluate the fatigue in SSVEP-based BCIs. Methods How the EEG indices (amplitudes in δ, θ, α and β frequency bands), the selected ratio indices (θ/α and (θ + α)/β), and SSVEP properties (amplitude and signal-to-noise ratio (SNR)) changes with the increasing fatigue level are investigated through two elaborate SSVEP-based BCI experiments, one validates mainly the effectiveness and another considers more practical situations. Meanwhile, a self-reported fatigue questionnaire is used to provide a subjective reference. ANOVA is employed to test the significance of the difference between the alert state and the fatigue state for each index. Results Consistent results are obtained in two experiments: the significant increases in α and (θ + α)/β, as well as the decrease in θ/α are found associated with the increasing fatigue level, indicating that EEG spectral analysis can provide robust objective evaluation of the fatigue in SSVEP-based BCIs. Moreover, the results show that the amplitude and SNR of the elicited SSVEP are significantly affected by users’ fatigue. Conclusions The experiment results demonstrate the feasibility and effectiveness of the proposed method as an objective and real-time evaluation of the fatigue in SSVEP-based BCIs. This method would be helpful in understanding the fatigue problem and optimizing the system design to alleviate the fatigue in SSVEP-based BCIs.
Collapse
Affiliation(s)
| | - Feng Wan
- Department of Electrical and Computer Engineering, University of Macau, Macau, China.
| | | | | | | |
Collapse
|
29
|
Wang L, Zhang X, Zhong X, Zhang Y. Analysis and classification of speech imagery EEG for BCI. Biomed Signal Process Control 2013. [DOI: 10.1016/j.bspc.2013.07.011] [Citation(s) in RCA: 82] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
30
|
Yeh CL, Lee PL, Chen WM, Chang CY, Wu YT, Lan GY. Improvement of classification accuracy in a phase-tagged steady-state visual evoked potential-based brain computer interface using multiclass support vector machine. Biomed Eng Online 2013; 12:46. [PMID: 23692974 PMCID: PMC3671978 DOI: 10.1186/1475-925x-12-46] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2012] [Accepted: 04/29/2013] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Brain computer interface (BCI) is an emerging technology for paralyzed patients to communicate with external environments. Among current BCIs, the steady-state visual evoked potential (SSVEP)-based BCI has drawn great attention due to its characteristics of easy preparation, high information transfer rate (ITR), high accuracy, and low cost. However, electroencephalogram (EEG) signals are electrophysiological responses reflecting the underlying neural activities which are dependent upon subject's physiological states (e.g., emotion, attention, etc.) and usually variant among different individuals. The development of classification approaches to account for each individual's difference in SSVEP is needed but was seldom reported. METHODS This paper presents a multiclass support vector machine (SVM)-based classification approach for gaze-target detections in a phase-tagged SSVEP-based BCI. In the training steps, the amplitude and phase features of SSVEP from off-line recordings were used to train a multiclass SVM for each subject. In the on-line application study, effective epochs which contained sufficient SSVEP information of gaze targets were first determined using Kolmogorov-Smirnov (K-S) test, and the amplitude and phase features of effective epochs were subsequently inputted to the multiclass SVM to recognize user's gaze targets. RESULTS The on-line performance using the proposed approach has achieved high accuracy (89.88 ± 4.76%), fast responding time (effective epoch length = 1.13 ± 0.02 s), and the information transfer rate (ITR) was 50.91 ± 8.70 bits/min. CONCLUSIONS The multiclass SVM-based classification approach has been successfully implemented to improve the classification accuracy in a phase-tagged SSVEP-based BCI. The present study has shown the multiclass SVM can be effectively adapted to each subject's SSVEPs to discriminate SSVEP phase information from gazing at different gazed targets.
Collapse
Affiliation(s)
- Chia-Lung Yeh
- Department of Electrical Engineering, National Central University, Jhongli, Taiwan
| | | | | | | | | | | |
Collapse
|
31
|
Thompson DE, Blain-Moraes S, Huggins JE. Performance assessment in brain-computer interface-based augmentative and alternative communication. Biomed Eng Online 2013; 12:43. [PMID: 23680020 PMCID: PMC3662584 DOI: 10.1186/1475-925x-12-43] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2012] [Accepted: 04/17/2013] [Indexed: 11/14/2022] Open
Abstract
A large number of incommensurable metrics are currently used to report the performance of brain-computer interfaces (BCI) used for augmentative and alterative communication (AAC). The lack of standard metrics precludes the comparison of different BCI-based AAC systems, hindering rapid growth and development of this technology. This paper presents a review of the metrics that have been used to report performance of BCIs used for AAC from January 2005 to January 2012. We distinguish between Level 1 metrics used to report performance at the output of the BCI Control Module, which translates brain signals into logical control output, and Level 2 metrics at the Selection Enhancement Module, which translates logical control to semantic control. We recommend that: (1) the commensurate metrics Mutual Information or Information Transfer Rate (ITR) be used to report Level 1 BCI performance, as these metrics represent information throughput, which is of interest in BCIs for AAC; 2) the BCI-Utility metric be used to report Level 2 BCI performance, as it is capable of handling all current methods of improving BCI performance; (3) these metrics should be supplemented by information specific to each unique BCI configuration; and (4) studies involving Selection Enhancement Modules should report performance at both Level 1 and Level 2 in the BCI system. Following these recommendations will enable efficient comparison between both BCI Control and Selection Enhancement Modules, accelerating research and development of BCI-based AAC systems.
Collapse
Affiliation(s)
- David E Thompson
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Stefanie Blain-Moraes
- Department of Physical Medicine and Rehabilitation, University of Michigan, Ann Arbor, MI, USA
| | - Jane E Huggins
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
- Department of Physical Medicine and Rehabilitation, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|