1
|
Han H, Zhang J, Yang H, Hou Y, Qiao J. Data-Driven Robust Optimal Control for Nonlinear System with Uncertain Disturbances. Inf Sci (N Y) 2022. [DOI: 10.1016/j.ins.2022.11.092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
2
|
Rabby MF, Tu Y, Hossen MI, Lee I, Maida AS, Hei X. Stacked LSTM based deep recurrent neural network with kalman smoothing for blood glucose prediction. BMC Med Inform Decis Mak 2021; 21:101. [PMID: 33726723 PMCID: PMC7968367 DOI: 10.1186/s12911-021-01462-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Accepted: 03/03/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Blood glucose (BG) management is crucial for type-1 diabetes patients resulting in the necessity of reliable artificial pancreas or insulin infusion systems. In recent years, deep learning techniques have been utilized for a more accurate BG level prediction system. However, continuous glucose monitoring (CGM) readings are susceptible to sensor errors. As a result, inaccurate CGM readings would affect BG prediction and make it unreliable, even if the most optimal machine learning model is used. METHODS In this work, we propose a novel approach to predicting blood glucose level with a stacked Long short-term memory (LSTM) based deep recurrent neural network (RNN) model considering sensor fault. We use the Kalman smoothing technique for the correction of the inaccurate CGM readings due to sensor error. RESULTS For the OhioT1DM (2018) dataset, containing eight weeks' data from six different patients, we achieve an average RMSE of 6.45 and 17.24 mg/dl for 30 min and 60 min of prediction horizon (PH), respectively. CONCLUSIONS To the best of our knowledge, this is the leading average prediction accuracy for the ohioT1DM dataset. Different physiological information, e.g., Kalman smoothed CGM data, carbohydrates from the meal, bolus insulin, and cumulative step counts in a fixed time interval, are crafted to represent meaningful features used as input to the model. The goal of our approach is to lower the difference between the predicted CGM values and the fingerstick blood glucose readings-the ground truth. Our results indicate that the proposed approach is feasible for more reliable BG forecasting that might improve the performance of the artificial pancreas and insulin infusion system for T1D diabetes management.
Collapse
Affiliation(s)
- Md Fazle Rabby
- School of Computing and Informatics, The University of Louisiana at Lafayette, Lafayatte, LA 70503 USA
| | - Yazhou Tu
- School of Computing and Informatics, The University of Louisiana at Lafayette, Lafayatte, LA 70503 USA
| | - Md Imran Hossen
- School of Computing and Informatics, The University of Louisiana at Lafayette, Lafayatte, LA 70503 USA
| | - Insup Lee
- Department of Computer and Information Science, University of Pennsylvania, Philadelphia, PA 19104 USA
| | - Anthony S. Maida
- School of Computing and Informatics, The University of Louisiana at Lafayette, Lafayatte, LA 70503 USA
| | - Xiali Hei
- School of Computing and Informatics, The University of Louisiana at Lafayette, Lafayatte, LA 70503 USA
| |
Collapse
|
3
|
Intelligent automated drug administration and therapy: future of healthcare. Drug Deliv Transl Res 2021; 11:1878-1902. [PMID: 33447941 DOI: 10.1007/s13346-020-00876-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/09/2020] [Indexed: 12/13/2022]
Abstract
In the twenty-first century, the collaboration of control engineering and the healthcare sector has matured to some extent; however, the future will have promising opportunities, vast applications, and some challenges. Due to advancements in processing speed, the closed-loop administration of drugs has gained popularity for critically ill patients in intensive care units and routine life such as personalized drug delivery or implantable therapeutic devices. For developing a closed-loop drug delivery system, the control system works with a group of technologies like sensors, micromachining, wireless technologies, and pharmaceuticals. Recently, the integration of artificial intelligence techniques such as fuzzy logic, neural network, and reinforcement learning with the closed-loop drug delivery systems has brought their applications closer to fully intelligent automatic healthcare systems. This review's main objectives are to discuss the current developments, possibilities, and future visions in closed-loop drug delivery systems, for providing treatment to patients suffering from chronic diseases. It summarizes the present insight of closed-loop drug delivery/therapy for diabetes, gastrointestinal tract disease, cancer, anesthesia administration, cardiac ailments, and neurological disorders, from a perspective to show the research in the area of control theory.
Collapse
|
4
|
Artificial Pancreas Control Strategies Used for Type 1 Diabetes Control and Treatment: A Comprehensive Analysis. APPLIED SYSTEM INNOVATION 2020. [DOI: 10.3390/asi3030031] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
This paper presents a comprehensive survey about the fundamental components of the artificial pancreas (AP) system including insulin administration and delivery, glucose measurement (GM), and control strategies/algorithms used for type 1 diabetes mellitus (T1DM) treatment and control. Our main focus is on the T1DM that emerges due to pancreas’s failure to produce sufficient insulin due to the loss of beta cells (β-cells). We discuss various insulin administration and delivery methods including physiological methods, open-loop, and closed-loop schemes. Furthermore, we report several factors such as hyperglycemia, hypoglycemia, and many other physical factors that need to be considered while infusing insulin in human body via AP systems. We discuss three prominent control algorithms including proportional-integral- derivative (PID), fuzzy logic, and model predictive, which have been clinically evaluated and have all shown promising results. In addition, linear and non-linear insulin infusion control schemes have been formally discussed. To the best of our knowledge, this is the first work which systematically covers recent developments in the AP components with a solid foundation for future studies in the T1DM field.
Collapse
|
5
|
Li K, Daniels J, Liu C, Herrero P, Georgiou P. Convolutional Recurrent Neural Networks for Glucose Prediction. IEEE J Biomed Health Inform 2020; 24:603-613. [DOI: 10.1109/jbhi.2019.2908488] [Citation(s) in RCA: 84] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
6
|
Karsaz A. Chattering -free hybrid adaptive neuro-fuzzy inference system-particle swarm optimisation data fusion-based BG-level control. IET Syst Biol 2020; 14:31-38. [PMID: 31931479 DOI: 10.1049/iet-syb.2018.5019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
In this study, a closed-loop control scheme is proposed for the glucose-insulin regulatory system in type-1 diabetic mellitus (T1DM) patients. Some innovative hybrid glucose-insulin regulators have combined artificial intelligence such as fuzzy logic and genetic algorithm with well known Palumbo model to regulate the blood glucose (BG) level in T1DM patients. However, most of these approaches have focused on the glucose reference tracking, and the qualitative of this tracking such as chattering reduction of insulin injection has not been well-studied. Higher-order sliding mode (HoSM) controllers have been employed to attenuate the effect of chattering. Owing to the delayed nature and non-linear property of glucose-insulin mechanism as well as various unmeasurable disturbances, even the HoSM methods are partly successful. In this study, data fusion of adaptive neuro-fuzzy inference systems optimised by particle swarm optimisation has been presented. The excellent performance of the proposed hybrid controller, i.e. desired BG-level tracking and chattering reduction in the presence of daily glucose-level disturbances is verified.
Collapse
Affiliation(s)
- Ali Karsaz
- Department of Electrical and Electronic Engineering, Khorasan Institute of Higher Education, Mashhad, Iran.
| |
Collapse
|
7
|
Gunduz A, Opri E, Gilron R, Kremen V, Worrell G, Starr P, Leyde K, Denison T. Adding wisdom to 'smart' bioelectronic systems: a design framework for physiologic control including practical examples. ACTA ACUST UNITED AC 2019; 2:29-41. [PMID: 33868718 PMCID: PMC7610621 DOI: 10.2217/bem-2019-0008] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
This perspective provides an overview of how risk can be effectively considered in physiological control loops that strive for semi-to-fully automated operation. The perspective first introduces the motivation, user needs and framework for the design of a physiological closed-loop controller. Then, we discuss specific risk areas and use examples from historical medical devices to illustrate the key concepts. Finally, we provide a design overview of an adaptive bidirectional brain–machine interface, currently undergoing human clinical studies, to synthesize the design principles in an exemplar application.
Collapse
Affiliation(s)
- Aysegul Gunduz
- Department of Biomedical Engineering, University of Florida Gainesville, Gainesville, FL 32611, USA
| | - Enrico Opri
- Department of Biomedical Engineering, University of Florida Gainesville, Gainesville, FL 32611, USA
| | - Ro'ee Gilron
- School of Medicine, University of California San Francisco, San Francisco CA 94143, USA
| | - Vaclav Kremen
- Department of Neurology, Mayo Clinic, Rochester, MN 55905, USA
| | - Gregory Worrell
- Department of Neurology, Mayo Clinic, Rochester, MN 55905, USA
| | - Phil Starr
- School of Medicine, University of California San Francisco, San Francisco CA 94143, USA
| | - Kent Leyde
- Cadence Neuroscience Inc, Sammamish, WA 98074, USA
| | - Timothy Denison
- Department of Engineering Science, University of Oxford, Oxford, OX3 7DQ, UK
| |
Collapse
|
8
|
Shirin A, Della Rossa F, Klickstein I, Russell J, Sorrentino F. Optimal regulation of blood glucose level in Type I diabetes using insulin and glucagon. PLoS One 2019; 14:e0213665. [PMID: 30893335 PMCID: PMC6426249 DOI: 10.1371/journal.pone.0213665] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Accepted: 02/26/2019] [Indexed: 12/11/2022] Open
Abstract
The Glucose-Insulin-Glucagon nonlinear model accurately describes how the body responds to exogenously supplied insulin and glucagon in patients affected by Type I diabetes. Based on this model, we design infusion rates of either insulin (monotherapy) or insulin and glucagon (dual therapy) that can optimally maintain the blood glucose level within desired limits after consumption of a meal and prevent the onset of both hypoglycemia and hyperglycemia. This problem is formulated as a nonlinear optimal control problem, which we solve using the numerical optimal control package PSOPT. Interestingly, in the case of monotherapy, we find the optimal solution is close to the standard method of insulin based glucose regulation, which is to assume a variable amount of insulin half an hour before each meal. We also find that the optimal dual therapy (that uses both insulin and glucagon) is better able to regulate glucose as compared to using insulin alone. We also propose an ad-hoc rule for both the dosage and the time of delivery of insulin and glucagon.
Collapse
Affiliation(s)
- Afroza Shirin
- Mechanical Engineering Department, University of New Mexico, Albuquerque, NM 87131, United States of America
- * E-mail:
| | - Fabio Della Rossa
- Mechanical Engineering Department, University of New Mexico, Albuquerque, NM 87131, United States of America
| | - Isaac Klickstein
- Mechanical Engineering Department, University of New Mexico, Albuquerque, NM 87131, United States of America
| | - John Russell
- Mechanical Engineering Department, University of New Mexico, Albuquerque, NM 87131, United States of America
| | - Francesco Sorrentino
- Mechanical Engineering Department, University of New Mexico, Albuquerque, NM 87131, United States of America
| |
Collapse
|
9
|
Nandi S, Singh T. Glycemic Control of People With Type 1 Diabetes Based on Probabilistic Constraints. IEEE J Biomed Health Inform 2018; 23:1773-1783. [PMID: 30207967 DOI: 10.1109/jbhi.2018.2869365] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The objective of the paper is to develop an open loop insulin infusion profile, which is capable of controlling the blood glucose level of people with Type 1 diabetes in the presence of broad uncertainties such as inter-patient variability and unknown meal quantity. For illustrative purposes, the Bergman model in conjunction with a gut-dynamics model is chosen to represent the human glucose-insulin dynamics. A recently developed sampling based uncertainty quantification approach is used to determine the statistics (mean and variance) of the evolving states in the model. These statistics are utilized to define chance constraints in an optimization framework. The solution obtained shows that under the assumptions made on the distribution of the model parameters, all possible glucose trajectories over time satisfy the desired glycemic control goals. The solution is also validated on the FDA approved Type 1 Diabetes Metabolic Simulator suggesting that the proposed algorithm is highly suitable for human subjects.
Collapse
|
10
|
Gondhalekar R, Dassau E, Doyle FJ. Velocity-weighting & velocity-penalty MPC of an artificial pancreas: Improved safety & performance. AUTOMATICA : THE JOURNAL OF IFAC, THE INTERNATIONAL FEDERATION OF AUTOMATIC CONTROL 2018; 91:105-117. [PMID: 30034017 PMCID: PMC6051553 DOI: 10.1016/j.automatica.2018.01.025] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
A novel Model Predictive Control (MPC) law for the closed-loop operation of an Artificial Pancreas (AP) to treat type 1 diabetes is proposed. The contribution of this paper is to simultaneously enhance both the safety and performance of an AP, by reducing the incidence of controller-induced hypoglycemia, and by promoting assertive hyperglycemia correction. This is achieved by integrating two MPC features separately introduced by the authors previously to independently improve the control performance with respect to these two coupled issues. Velocity-weighting MPC reduces the occurrence of controller-induced hypoglycemia. Velocity-penalty MPC yields more effective hyperglycemia correction. Benefits of the proposed MPC law over the MPC strategy deployed in the authors' previous clinical trial campaign are demonstrated via a comprehensive in-silico analysis. The proposed MPC law was deployed in four distinct US Food & Drug Administration approved clinical trial campaigns, the most extensive of which involved 29 subjects each spending three months in closed-loop. The paper includes implementation details, an explanation of the state-dependent cost functions required for velocity-weighting and penalties, a discussion of the resulting nonlinear optimization problem, a description of the four clinical trial campaigns, and control-related trial highlights.
Collapse
Affiliation(s)
- Ravi Gondhalekar
- Harvard John A. Paulson School of Engineering & Applied Sciences, Harvard University, Cambridge, MA, USA
| | - Eyal Dassau
- Harvard John A. Paulson School of Engineering & Applied Sciences, Harvard University, Cambridge, MA, USA
| | - Francis J Doyle
- Harvard John A. Paulson School of Engineering & Applied Sciences, Harvard University, Cambridge, MA, USA
| |
Collapse
|
11
|
Nath A, Biradar S, Balan A, Dey R, Padhi R. Physiological Models and Control for Type 1 Diabetes Mellitus: A Brief Review. ACTA ACUST UNITED AC 2018. [DOI: 10.1016/j.ifacol.2018.05.077] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
12
|
Naşcu I, Pistikopoulos EN. A multiparametric model-based optimization and control approach to anaesthesia. CAN J CHEM ENG 2016. [DOI: 10.1002/cjce.22634] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Affiliation(s)
- Ioana Naşcu
- Department of Chemical Engineering, Centre for Process Systems Engineering (CPSE); Imperial College London SW7 2AZ; London UK
- Artie McFerrin Department of Chemical Engineering; Texas A&M, College Station; TX USA
| | | |
Collapse
|