1
|
Sechi A, Wortsman X, Tosti A, Iorizzo M. Advances in image-based diagnosis of nail disorders. J Eur Acad Dermatol Venereol 2025; 39:759-774. [PMID: 39230323 DOI: 10.1111/jdv.20309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Accepted: 07/02/2024] [Indexed: 09/05/2024]
Abstract
This paper provides a comprehensive overview of image-based techniques, particularly focusing on their applications and advancements in the context of nail disorders. Nowadays, high-resolution digital cameras and dermoscopes enable dermatologists to capture detailed images of nail abnormalities, facilitating early diagnosis and meticulous tracking of disease progression. Onychoscopy is now a routine technique with well-known criteria for the diagnosis, but recent developments allow us to visualize certain diseases better. Imaging modalities like high-frequency ultrasound, magnetic resonance imaging, optical coherence tomography and confocal microscopy are being increasingly adopted for their superior diagnostic capabilities. These techniques are described in their technology, scanning protocols, normal findings, advantages and limitations. Moreover, the integration of technology in patient education has fostered a more informed patient population, capable of actively participating in their disease monitoring and treatment regimens. Proper training, validation, regulation and ethical considerations are, however, essential when integrating technology into healthcare practices. Imaging technologies that present the potential to add critical anatomical information to clinical diagnoses within reasonable costs and are available worldwide are the ones that will probably be used the most.
Collapse
Affiliation(s)
- Andrea Sechi
- Dermatology Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
- Department of Dermatology and Cutaneous Surgery, Miller School of Medicine, University of Miami, Miami, Florida, USA
| | - Ximena Wortsman
- Department of Dermatology and Cutaneous Surgery, Miller School of Medicine, University of Miami, Miami, Florida, USA
- Department of Dermatology, Faculty of Medicine, Universidad de Chile, Santiago, Chile
- Department of Dermatology, School of Medicine, Pontificia Universidad Catolica de Chile, Santiago, Chile
- Institute for Diagnostic Imaging and Research of the Skin and Soft Tissues, Santiago, Chile
| | - Antonella Tosti
- Fredric Brandt Endowed Professor of Dermatology - Mille School of Medicine, University of Miami, Miami, Florida, USA
| | - Matilde Iorizzo
- Private Dermatology Practice, Bellinzona/Lugano, Switzerland
| |
Collapse
|
2
|
Strohm EM, Wu D, Malounda D, Nayak R, Shapiro MG, Kolios MC. Pressure estimation of ultra-high frequency ultrasound using gas vesicles. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 156:4193-4201. [PMID: 39714195 DOI: 10.1121/10.0034438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/16/2024] [Accepted: 10/31/2024] [Indexed: 12/24/2024]
Abstract
Acoustic microscopy uses ultra-high frequency (UHF) ultrasound transducers over 80 MHz to perform high-resolution imaging. The pressure output of these transducers is unknown, as commercial calibrated hydrophones can measure pressure for transducers with frequencies only up to 80 MHz. This study used gas vesicle nanostructures (GVs) that collapse at 571 kPa to estimate the pressure of UHF transducers at 40, 80, 200, and 375 MHz. Agarose phantoms containing GVs were made, and a baseline ultrasound image was performed at low pressure to prevent GV collapse. Sections within the phantom were scanned at varying voltage to determine the GV collapse threshold. The pressure at full driving voltage was then calculated, assuming a linear relation between transducer voltage and pressure. The pressure calculated for the 40 MHz transducer was 2.2 ± 0.1 MPa at 21 °C. Using a hydrophone, the measured pressure was 2.1 ± 0.3 MPa, a difference of <2%, validating the method at this frequency. The pressure calculated for the other transducers was 2.0 ± 0.1 MPa (80 MHz), 1.2 ± 0.1 (200 MHz), and 1.05 ± 0.17 (375 MHz at 37 °C). This study addresses the challenge of estimating pressure output from UHF ultrasound transducers, demonstrating that the pressure output in the 40-400 MHz frequency range can be quantified.
Collapse
Affiliation(s)
- Eric M Strohm
- Department of Physics, Toronto Metropolitan University (formerly Ryerson University), Toronto, Ontario M5B 2K3, Canada
- Institute for Biomedical Engineering, Science and Technology, A Partnership Between Toronto Metropolitan University and St. Michael's Hospital, Toronto, Ontario M5B 2K3, Canada
- Keenan Research Centre for Biomedical Science, St. Michael's Hospital, Toronto, Ontario M5B 1T8, Canada
| | - Di Wu
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, USA
| | - Dina Malounda
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, USA
| | - Rohit Nayak
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, USA
| | - Mikhail G Shapiro
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, USA
- Division of Engineering and Applied Science, California Institute of Technology, Pasadena, California 91125, USA
- Howard Hughes Medical Institute, California Institute of Technology, Pasadena, California 91125, USA
| | - Michael C Kolios
- Department of Physics, Toronto Metropolitan University (formerly Ryerson University), Toronto, Ontario M5B 2K3, Canada
- Institute for Biomedical Engineering, Science and Technology, A Partnership Between Toronto Metropolitan University and St. Michael's Hospital, Toronto, Ontario M5B 2K3, Canada
- Keenan Research Centre for Biomedical Science, St. Michael's Hospital, Toronto, Ontario M5B 1T8, Canada
| |
Collapse
|
3
|
Ito K, Hoerig C, Dan YS, McFadden SA, Mamou J, Hoang QV. Biomechanical changes occur in myopic choroidal stroma and mirror those in the adjacent sclera. COMMUNICATIONS ENGINEERING 2024; 3:139. [PMID: 39384899 PMCID: PMC11464896 DOI: 10.1038/s44172-024-00280-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Accepted: 09/04/2024] [Indexed: 10/11/2024]
Abstract
Retina-derived growth signals relayed from the choroid to the sclera cause remodeling of the extracellular scleral matrix, resulting in myopic ocular elongation. However, to the best of our knowledge, no studies have assessed changes in choroidal stromal biomechanical properties during myopia progression. Here we utilized 7 µm-resolution scanning acoustic microscopy (SAM) to assess biomechanical properties (bulk modulus (K) and mass density (rho)) of choroidal stroma from guinea pig eyes with form-deprivation (FD) induced myopia. The choroidal stroma had considerable intrinsic strength arising from its biomechanical properties and these were differentially affected by myopia in central and peripheral regions. Choroidal stromal biomechanical values were also highly correlated with those in adjacent scleral regions, and the choroidal stromal-scleral association was stronger in myopic eyes. Biomechanical changes observed in the choroidal stroma of myopic eyes were mirrored to those observed in the adjacent sclera. These findings suggest that choroidal stromal remodeling may accompany myopia and open the door to the source of the signals that cause scleral remodeling in myopia.
Collapse
Affiliation(s)
- Kazuyo Ito
- Singapore Eye Research Institute, Singapore National Eye Centre, Duke-NUS Medical School, Singapore, Singapore
- Division of Advanced Applied Physics, Institute of Engineering, Tokyo University of Agriculture and Technology, Tokyo, Japan
- Department of Biomedical Engineering, Graduate School of Engineering, Tokyo University of Agriculture and Technology, Tokyo, Japan
| | - Cameron Hoerig
- Department of Radiology, Weill Cornell Medicine, New York, NY, USA
| | - Yee Shan Dan
- Singapore Eye Research Institute, Singapore National Eye Centre, Duke-NUS Medical School, Singapore, Singapore
| | - Sally A McFadden
- Vision Sciences, School of Psychological Sciences, College of Engineering, Science and Environment, University of Newcastle, Newcastle, NSW, Australia.
- Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore.
| | - Jonathan Mamou
- Department of Radiology, Weill Cornell Medicine, New York, NY, USA.
| | - Quan V Hoang
- Singapore Eye Research Institute, Singapore National Eye Centre, Duke-NUS Medical School, Singapore, Singapore.
- Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore.
- Department of Ophthalmology, Columbia University Irving Medical Center, New York, NY, USA.
| |
Collapse
|
4
|
Zhao J, Fei C, He J, He D, Wang Y, Chen J, Li Z, Quan Y, Zhao T, Lou L, Qiu Z, Yang Y. Ultra-High Frequency Self-Focusing Ultrasonic Sensors With Half-Concave Geometry for Visualization of Mouse Brain Atrophy. IEEE Trans Biomed Eng 2024; 71:524-530. [PMID: 37656645 DOI: 10.1109/tbme.2023.3308574] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/03/2023]
Abstract
Ultra-high frequency (>100 MHz) acoustic waves feature biocompatibility and high sensitivity and allow biomedical imaging and acoustic tweezers. Primarily, excellent spatial resolution and broad bandwidth at ultra-high frequency is the goal for pathological research and cell selection at the cellular level. Here, we propose an efficient approach to visualize mouse brain atrophy by self-focused ultrasonic sensors at ultra-high frequency with ultra-broad bandwidth. The numerical models of geometry and theoretically predicted acoustic parameters for half-concave piezoelectric elements are calculated by the differential method, which agrees with measured results (lateral resolution: 24 μm, and bandwidth: 115% at -6 dB). Compared with the brain slices of 2-month-old mouse, the atrophy visualization of the 6-month-old mouse brain was realized by C-mode imaging with an acoustic microscopy system, which is a potential prospect for diagnosis and treatment of Alzheimer's disease (AD) combined with neuroscience. Meanwhile, the acoustic properties of the brain slices were quantitatively measured by the acoustic microscopy. These encouraging results demonstrate the promising application for high-resolution imaging in vitro biological tissue with ultra-high frequency self-focusing ultrasonic sensors.
Collapse
|
5
|
Lu JY. Modulation of Point Spread Function for Super-Resolution Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2024; 71:153-171. [PMID: 37988211 DOI: 10.1109/tuffc.2023.3335883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2023]
Abstract
High image resolution is desired in wave-related areas such as ultrasound, acoustics, optics, and electromagnetics. However, the spatial resolution of an imaging system is limited by the spatial frequency of the point spread function (PSF) of the system due to diffraction. In this article, the PSF is modulated in amplitude, phase, or both to increase the spatial frequency to reconstruct super-resolution images of objects or wave sources/fields, where the modulator can be a focused shear wave produced remotely by, for example, a radiation force from a focused Bessel beam or X-wave, or can be a small particle manipulated remotely by a radiation-force (such as acoustic and optical tweezers) or electrical and magnetic forces. A theory of the PSF-modulation method was developed, and computer simulations and experiments were conducted. The result of an ultrasound experiment shows that a pulse-echo (two-way) image reconstructed has a super-resolution (0.65 mm) as compared to the diffraction limit (2.65 mm) using a 0.5-mm-diameter modulator at 1.483-mm wavelength, and the signal-to-noise ratio (SNR) of the image was about 31 dB. If the minimal SNR of a "visible" image is 3, the resolution can be further increased to about 0.19 mm by decreasing the size of the modulator. Another ultrasound experiment shows that a wave source was imaged (one-way) at about 30-dB SNR using the same modulator size and wavelength above. The image clearly separated two 0.5-mm spaced lines, which gives a 7.26-fold higher resolution than that of the diffraction limit (3.63 mm). Although, in theory, the method has no limit on the highest achievable image resolution, in practice, the resolution is limited by noises. Also, a PSF-weighted super-resolution imaging method based on the PSF-modulation method was developed. This method is easier to implement but may have some limitations. Finally, the methods above can be applied to imaging systems of an arbitrary PSF and can produce 4-D super-resolution images. With a proper choice of a modulator (e.g., a quantum dot) and imaging system, nanoscale (a few nanometers) imaging is possible.
Collapse
|
6
|
Rad IJ, Chapman L, Tupally KR, Veidt M, Al-Sadiq H, Sullivan R, Parekh HS. A systematic review of ultrasound-mediated drug delivery to the eye and critical insights to facilitate a timely path to the clinic. Theranostics 2023; 13:3582-3638. [PMID: 37441595 PMCID: PMC10334839 DOI: 10.7150/thno.82884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Accepted: 05/11/2023] [Indexed: 07/15/2023] Open
Abstract
Ultrasound has long been identified as a promising, non-invasive modality for improving ocular drug delivery across a range of indications. Yet, with 20 years of learnings behind us, clinical translation remains limited. To help address this, and in accordance with PRISMA guidelines, the various mechanisms of ultrasound-mediated ocular drug delivery have been appraised, ranging from first principles to emergent applications spanning both ex vivo and in vivo models. The heterogeneity of study methods precluded meta-analysis, however an extensive characterisation of the included studies allowed for semi-quantitative and qualitative assessments. Methods: In this review, we reflected on study quality of reporting, and risk of bias (RoB) using the latest Animal Research: Reporting of In Vivo Experiments (ARRIVE 2.0) guidelines, alongside the Systematic Review Centre for Laboratory animal Experimentation (SYRCLE) RoB tools. Literature studies from 2002 to 2022 were initially characterised according to methods of ultrasound application, ultrasound parameters applied, animal models employed, as well as safety and efficacy assessments. This exercise contributed to developing a comprehensive understanding of the current state of play within ultrasound-mediated ocular drug delivery. The results were then synthesised and processed into a guide to aid future study design, with the goal of improving the reliability of data, and to support efficient and timely translation to the clinic. Results: Key attributes identified as hindering translation included: poor reporting quality and high RoB, skewed use of animals unrepresentative of the human eye, and the over reliance of reductionist safety assessments. Ex vivo modelling studies were often unable to have comprehensive safety assessments performed on them, which are imperative to determining treatment safety, and represent a pre-requisite for clinical translation. Conclusion: With the use of our synthesised guide, and a thorough understanding of the underlying physicochemical interactions between ultrasound and ocular biology provided herein, this review offers a firm foundation on which future studies should ideally be built, such that ultrasound-mediated ocular drug delivery can be translated from concept to the coalface where it can provide immense clinical benefit.
Collapse
Affiliation(s)
- Isaac J Rad
- The University of Queensland, School of Pharmacy, Brisbane, Queensland, Australia
- The University of Queensland, Faculty of Medicine, Brisbane, Queensland, Australia
| | - Luke Chapman
- The University of Queensland, Faculty of Medicine, Brisbane, Queensland, Australia
| | | | - Martin Veidt
- The University of Queensland, School of Mechanical and Mining Engineering, Brisbane, Queensland, Australia
| | - Hussain Al-Sadiq
- Al-Asala University, Department of Industrial Engineering, Dammam, Saudi Arabia
| | - Robert Sullivan
- The University of Queensland, Queensland Brain Institute, Brisbane, Queensland, Australia
| | - Harendra S Parekh
- The University of Queensland, School of Pharmacy, Brisbane, Queensland, Australia
| |
Collapse
|
7
|
Chen J, Fei C, Zhao J, Quan Y, Wang Y, Jiang Z, Wen L. Ultrahigh Frequency Ultrasonic Transducers (150MHz) Based on Silicon Lenses. MICROMACHINES 2023; 14:213. [PMID: 36677274 PMCID: PMC9863337 DOI: 10.3390/mi14010213] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 01/01/2023] [Accepted: 01/03/2023] [Indexed: 06/17/2023]
Abstract
Acoustic microscopes and acoustic tweezers have great value in the application of microparticle manipulation, biomedical research and non-destructive testing. Ultrahigh frequency (UHF) ultrasonic transducers act as the key component in acoustic microscopes, and acoustic tweezers and acoustic lenses are essential parts of UHF ultrasonic transducers. Therefore, the preparation of acoustic lenses is crucial. Silicon is a suitable material for preparing acoustic lenses because of its high acoustic velocity, low acoustic attenuation and excellent machinability. In previous research, silicon lenses were mainly prepared by etching. However, etching has some drawbacks. The etching of large sizes is complex, time-consuming and expensive. Furthermore, vertical etching is preferred to spherical etching. Thus, a new method of ultra-precision machining was introduced to prepare silicon lenses. In this paper, silicon lenses with an aperture of 892 μm and a depth of 252 μm were prepared. Then, UHF ultrasonic transducers with a center frequency of 157 MHz and a -6-dB bandwidth of 52% were successfully prepared based on silicon lenses. The focal distance of the transducers was 736 μm and the F-number was about 0.82. The transducers had a lateral resolution of 11 μm and could distinguish the 13 μm slots on silicon wafers clearly.
Collapse
Affiliation(s)
- Jun Chen
- School of Microelectronics, Xidian University, Xi’an 710071, China
| | - Chunlong Fei
- School of Microelectronics, Xidian University, Xi’an 710071, China
| | - Jianxin Zhao
- School of Microelectronics, Xidian University, Xi’an 710071, China
| | - Yi Quan
- School of Microelectronics, Xidian University, Xi’an 710071, China
| | - Yecheng Wang
- School of Microelectronics, Xidian University, Xi’an 710071, China
| | - Zhishui Jiang
- Guangdong JC Technological Innovation Electronics Co., Ltd., Zhaoqing 526000, China
| | - Li Wen
- Guangdong JC Technological Innovation Electronics Co., Ltd., Zhaoqing 526000, China
| |
Collapse
|
8
|
Hoerig C, Mamou J. Advanced Topics in Quantitative Acoustic Microscopy. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2023; 1403:253-277. [PMID: 37495922 DOI: 10.1007/978-3-031-21987-0_12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/28/2023]
Abstract
Quantitative acoustic microscopy (QAM) reconstructs two-dimensional (2D) maps of the acoustic properties of thin tissue sections. Using ultrahigh frequency transducers (≥ 100 MHz), unstained, micron-thick tissue sections affixed to glass are raster scanned to collect radiofrequency (RF) echo data and generate parametric maps with resolution approximately equal to the ultrasound wavelength. 2D maps of speed of sound, mass density, acoustic impedance, bulk modulus, and acoustic attenuation provide unique and quantitative information that is complementary to typical optical microscopy modalities. Consequently, many biomedical researchers have great interest in utilizing QAM instruments to investigate the acoustic and biomechanical properties of tissues at the micron scale. Unfortunately, current state-of-the-art QAM technology is costly, requires operation by a trained user, and is accompanied by substantial experimental challenges, many of which become more onerous as the transducer frequency is increased. In this chapter, typical QAM technology and standard image formation methods are reviewed. Then, novel experimental and signal processing approaches are presented with the specific goal of reducing QAM instrument costs and improving ease of use. These methods rely on modern techniques based on compressed sensing and sparsity-based deconvolution methods. Together, these approaches could serve as the basis of the next generation of QAM instruments that are affordable and provide high-resolution QAM images with turnkey solutions requiring nearly no training to operate.
Collapse
Affiliation(s)
- Cameron Hoerig
- Department of Radiology, Weill Cornell Medicine, New York, NY, USA
| | - Jonathan Mamou
- Department of Radiology, Weill Cornell Medicine, New York, NY, USA.
| |
Collapse
|
9
|
Biomechanical changes in myopic sclera correlate with underlying changes in microstructure. Exp Eye Res 2022; 224:109165. [PMID: 35810771 DOI: 10.1016/j.exer.2022.109165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 06/20/2022] [Accepted: 06/23/2022] [Indexed: 11/21/2022]
Abstract
Myopia alters the microstructural and biomechanical properties of the posterior sclera, which is characterized as a layered structure with potentially different inter-layer collagen fibril characteristics. Scanning acoustic microscopy (SAM) has been used to investigate how the micron-scale bulk mechanical properties of the posterior sclera are affected by myopia. Other investigators have employed second harmonic generation (SHG) imaging to characterize the collagen microstructure of tissues. In the present study, SAM and SHG imaging were used to investigate the existence of biomechanically-distinct scleral layers and identify relationships between mechanical properties and tissue microstructure in myopic guinea pig (GP) eyes. Diffusers were worn over the right eyes of six, 1-week-old GPs for one week to induce unilateral form-deprivation myopia. GPs were euthanized, enucleated, and eyes were cryosectioned. Twelve-micron-thick adjacent vertical cryosections were scanned with SAM or SHG. SAM maps of bulk modulus, mass density, and acoustic attenuation were estimated. A fiber-extraction algorithm applied to SHG images estimated collagen fiber length, width, straightness, alignment, and number density. Results revealed that the posterior sclera may exhibit biomechanically distinct layers that are affected differently in myopia. Specifically, a layered structure was observed in the mechanical-parameter maps of control eyes that was less apparent in myopic eyes. Collagen fibers in myopic eyes had smaller diameters and were more aligned. Myopia-associated biomechanical changes were most significant in the outermost and innermost scleral layers. SAM-measured mechanical parameters were correlated with collagen fiber microstructure, particularly fiber length, alignment, and number density, which may imply the biomechanical parameters estimated from SAM measurements are related to tissue microstructure. Interestingly, some changes were greatest in more-peripheral regions, suggesting interventions to strengthen the sclera may be effective away from the optic nerve and efficacy may be achieved best when intervention is applied to the outermost layer.
Collapse
|
10
|
Silverman RH, Urs R, Burgess M, Ketterling JA, Tezel G. High-Frequency Ultrasound Activation of Perfluorocarbon Nanodroplets for Treatment of Glaucoma. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:1910-1916. [PMID: 35020595 PMCID: PMC9709713 DOI: 10.1109/tuffc.2022.3142679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Elevated intraocular pressure (IOP) is the most prevalent risk factor for initiation and progression of neurodegeneration in glaucoma. Ocular hypertension results from increased resistance to aqueous fluid outflow caused by reduced porosity and increased stiffness of tissues of the outflow pathway. Acoustic activation and resulting bioeffects of the perfluorocarbon (PFC) nanodroplets (NDs) introduced into the anterior chamber (AC) of the eye could potentially represent a treatment for glaucoma by increasing permeability in the aqueous outflow track. To evaluate the potential of NDs to enter the outflow track, 100-nm diameter perfluoropentane (PFP) NDs with a lipid shell were injected into the AC of ex vivo pig eyes and in vivo rat eyes. The NDs were activated and imaged with 18- and 28-MHz linear arrays to assess their location and diffusion. NDs in the AC could also be visualized using optical coherence tomography (OCT). Because of their higher density with respect to aqueous humor, some NDs settled into the iridocorneal angle where they entered the outflow pathway. After acoustic activation of the NDs at the highest acoustic pressure, small gas bubbles were observed in the AC. After two days, no acoustic activation events were visible in the AC of the rats and their eyes showed no evidence of inflammation.
Collapse
|
11
|
Meriläinen A, Hyvönen J, Salmi A, Hæggström E. CESAM-Coded excitation scanning acoustic microscope. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:074901. [PMID: 34340418 DOI: 10.1063/5.0047351] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Scanning acoustic microscopy (SAM) finds use across many disciplines, e.g., biology, industrial quality control, and materials science, thanks to its unique ability to quantify mechanical sample properties combined with its high resolution. However, such imaging is often slow, especially if averaging is necessary. We present a Coded Excitation Scanning Acoustic Microscope (CESAM) that employs coded signals and show that it produces images of higher signal-to-noise ratios (SNRs) than the classical SAM in a comparable measurement time. The CESAM employs coded signals instead of the short bursts used in traditional SAMs, and we employ both linear and non-linear frequency modulation. Our results show that compared to the SAM approach, this modulation increases the SNR by 16.3 dB (from 39.9 to 56.2 dB) and reduces the echo duration by 26.7% when we employ a linear chirp to the transducer with a nominal bandwidth of 130-370 MHz. Driving the transducer with a broader bandwidth signal using non-linear chirps (100-450 MHz), we obtained a SNR increase of 10.3 dB and a reduced echo duration of 70.5%. The shorter echo duration increases z-resolution, whereas the lateral resolution remains limited by the wavelength. Finally, we show that by using these coded signals, one can obtain enhanced image quality relative to the standard actuation of the same measurement time. Our results have potential to invigorate the field of acoustic microscopy, especially with samples where the enhanced SNR and/or contrast-to-noise ratio is crucial for image quality.
Collapse
Affiliation(s)
- Antti Meriläinen
- Electronics Research Laboratory, Department of Physics, University of Helsinki, Gustaf Hällströmin katu 2, FIN 00560 Helsinki, Finland
| | - Jere Hyvönen
- Electronics Research Laboratory, Department of Physics, University of Helsinki, Gustaf Hällströmin katu 2, FIN 00560 Helsinki, Finland
| | - Ari Salmi
- Electronics Research Laboratory, Department of Physics, University of Helsinki, Gustaf Hällströmin katu 2, FIN 00560 Helsinki, Finland
| | - Edward Hæggström
- Electronics Research Laboratory, Department of Physics, University of Helsinki, Gustaf Hällströmin katu 2, FIN 00560 Helsinki, Finland
| |
Collapse
|
12
|
Tamura K, Mamou J, Yoshida K, Yamaguchi T, Franceschini E. Quantifying scattering from dense media using two-dimensional impedance maps. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 148:1681. [PMID: 33003867 DOI: 10.1121/10.0001972] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Accepted: 08/30/2020] [Indexed: 06/11/2023]
Abstract
A better understanding of ultrasound scattering in a three-dimensional (3D) medium can provide more accurate methods for ultrasound tissue characterization. The possibility of using two-dimensional impedance maps (2DZMs) based on correlation coefficients has shown promise in the case of isotropic and sparse medium [Luchies and Oelze, J. Acoust. Soc. Am. 139, 1557-1564 (2016)]. The present study investigates the use of 2DZMs in order to quantify 3D scatterer properties of dense media from two-dimensional (2D) histological slices. Two 2DZM approaches were studied: one based on the correlation coefficient and the other based on the 2D Fourier transform of 2DZMs. Both 2DZM approaches consist in estimating the backscatter coefficient (BSC) from several 2DZMs, and then the resulting BSC was fit to the theoretical polydisperse structure factor model to yield 3D scatterer properties. Simulation studies were performed to evaluate the ability of both 2DZM approaches to quantify scattering of a 3D medium containing randomly distributed polydisperse spheres or monodisperse ellipsoids. Experimental studies were also performed using the histology photomicrographs obtained from HT29 cell pellet phantoms. Results demonstrate that the 2DZM Fourier transform-based approach was more suitable than the correlation coefficient-based approach for estimating scatterer properties when using a small number of 2DZMs.
Collapse
Affiliation(s)
- Kazuki Tamura
- Department of Innovative Medical Photonics, Preeminent Medical Photonics Education and Research Center, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
| | - Jonathan Mamou
- Frederic L. Lizzi Center for Biomedical Engineering, Riverside Research, New York, New York, 10038, USA
| | - Kenji Yoshida
- Center for Frontier Medical Engineering, Chiba University, Chiba, Chiba, Japan
| | - Tadashi Yamaguchi
- Center for Frontier Medical Engineering, Chiba University, Chiba, Chiba, Japan
| | | |
Collapse
|
13
|
Makra A, Bost W, Kallo I, Horvath A, Fournelle M, Gyongy M. Enhancement of Acoustic Microscopy Lateral Resolution: A Comparison Between Deep Learning and Two Deconvolution Methods. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:136-145. [PMID: 31502966 DOI: 10.1109/tuffc.2019.2940003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Scanning acoustic microscopy (SAM) provides high-resolution images of biological tissues. Since higher transducer frequencies limit penetration depth, image resolution enhancement techniques could help in maintaining sufficient lateral resolution without sacrificing penetration depth. Compared with existing SAM research, this work introduces two novelties. First, deep learning (DL) is used to improve lateral resolution of 180-MHz SAM images, comparing it with two deconvolution-based approaches. Second, 316-MHz images are used as ground truth in order to quantitatively evaluate image resolution enhancement. The samples used were mouse and rat brain sections. The results demonstrate that DL can closely approximate ground truth (NRMSE = 0.056 and PSNR = 28.4 dB) even with a relatively limited training set (four images, each smaller than 1 mm ×1 mm). This study suggests the high potential of using DL as a single image superresolution method in SAM.
Collapse
|
14
|
Hoang QV, Rohrbach D, McFadden SA, Mamou J. Regional changes in the elastic properties of myopic Guinea pig sclera. Exp Eye Res 2019; 186:107739. [PMID: 31330141 PMCID: PMC6712578 DOI: 10.1016/j.exer.2019.107739] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2019] [Revised: 07/11/2019] [Accepted: 07/18/2019] [Indexed: 11/17/2022]
Abstract
Biomechanical changes in the sclera likely underlie the excessive eye elongation of axial myopia. We studied the biomechanical characteristics of myopic sclera at the microscopic level using scanning acoustic microscopy (SAM) with 7-μm in-plane resolution. Guinea pigs underwent form-deprivation (FD) in one eye from 4 to 12 days of age to induce myopia, and 12-μm-thick scleral cryosections were scanned using a custom-made SAM. Two-dimensional maps of the bulk modulus (K) and mass density (ρ) were derived from the SAM data using a frequency-domain approach. We assessed the effect on K and ρ exerted by: 1) level of induced myopia, 2) region (superior, inferior, nasal or temporal) and 3) eccentricity from the nerve using univariate and multivariate regression analyses. Induced myopia ranged between -3D and -9.3D (Mean intraocular difference of -6.2 ± 1.7D, N = 11). K decreased by 0.036 GPa for every 1.0 D increase in induced myopia across vertical sections (p < 0.001). Among induced myopia right eyes, K values in the inherently more myopic superior region were 0.088 GPa less than the inferior region (p = 0.002) and K in the proximal nasal region containing the central axis were 0.10 GPa less than temporal K (p = 0.036). K also increased 0.12 GPa for every 1 mm increase in superior vertical distance (p < 0.001), an effect that was blunted after 1 week of FD. Overall, trends for ρ were less apparent than for K. ρ values increased by 20.7 mg/cm3 for every 1.00 D increase in induced myopia across horizontal sections (p < 0.001), and were greatest in the region containing the central posterior pole. ρ values in the inherently more myopic superior region were 13.1 mg/cm3 greater than that found in inferior regions among control eyes (p = 0.002), and increased by 11.2 mg/cm3 for every 1 mm increase in vertical distance (p = 0.001). This peripheral increase in ρ was blunted after 1 week of FD. Scleral material properties vary depending on the location in the sclera and the level of induced myopia. Bulk modulus was most reduced in the most myopic regions (both induced myopia and inherent regional myopia), and suggests that FD causes microscopic local decreases in sclera stiffness, while scleral mass density was most increased in the most myopic regions.
Collapse
Affiliation(s)
- Quan V Hoang
- Department of Ophthalmology, Columbia University Medical Center, New York, NY, 10032, USA; Singapore Eye Research Institute, Singapore National Eye Centre, Duke-NUS Medical School, Singapore.
| | - Daniel Rohrbach
- Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY, 10038, USA
| | - Sally A McFadden
- Vision Sciences, School of Psychology, Faculty of Science and Hunter Medical Research Institute, University of Newcastle, NSW, Australia
| | - Jonathan Mamou
- Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY, 10038, USA
| |
Collapse
|
15
|
Mamou J, Pellegrini T, Kouame D, Basarab A. A Convolutional Neural Network for 250-MHz Quantitative Acoustic-microscopy Resolution Enhancement. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2019; 2019:6212-6215. [PMID: 31947262 DOI: 10.1109/embc.2019.8857865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Quantitative acoustic microscopy (QAM) permits the formation of quantitative two-dimensional (2D) maps of acoustic and mechanical properties of soft tissues at microscopic resolution. The 2D maps formed using our custom SAM systems employing a 250-MHz and a 500-MHz single-element transducer have a nominal resolution of 7 μm and 4μm, respectively. In a previous study, the potential of single-image super-resolution (SR) image post-processing to enhance the spatial resolution of 2D SAM maps was demonstrated using a forward model accounting for blur, decimation, and noise. However, results obtained when the SR method was applied to soft tissue data were not entirely satisfactory because of the limitation of the convolution model considered and by the difficulty of estimating the system point spread function and designing the appropriate regularization term. Therefore, in this study, a machine learning approach based on convolutional neural networks was implemented. For training, data acquired on the same samples at 250 and 500 MHz were used. The resulting trained network was tested on 2D impedance maps (2DZMs) of human lymph nodes acquired from breast-cancer patients. Visual inspection of the reconstructed enhanced 2DZMs were found similar to the 2DZMs obtained at 500 MHz which were used as ground truth. In addition, the enhanced 250-MHz 2DZMs obtained from the proposed method yielded better peak signal to noise ratio and normalized mean square error than those obtained with the previous SR method. This improvement was also demonstrated by the statistical analyses. This pioneering work could significantly reduce challenges and costs associated with current very high-frequency SAM systems while providing enhanced spatial resolution.
Collapse
|
16
|
Khalilian-Gourtani A, Wang Y, Mamou J. Scanning Acoustic Microscopy Image Super-Resolution using Bilateral Weighted Total Variation Regularization. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:5113-5116. [PMID: 30441491 DOI: 10.1109/embc.2018.8513411] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Scanning acoustic microscopy (SAM) is an imaging modality used to obtain 2D maps of acoustical and mechanical properties of soft tissues and uses ultrasound transducers operating at very high-frequencies. Such transducers are challenging and costly to manufacture, and SAM systems at higher frequencies become more sensitive to experimental issues. Nevertheless, biomedical applications of SAM often require spatial resolutions nearly as good as light microscopy. In addition, stained histology photomicrographs of thin sections of tissues are easily obtained with the necessary resolution and accuracy. Consequently, the aim of this study is to introduce a bilateral approach that enhances the resolution of SAM images by leveraging the co-registered high-resolution histology image. We propose to use bilateral weighted total variation regularization to solve the super-resolution problem. A fast matrix-less solver is developed by utilizing the Alternating Direction Method of Multipliers (ADMM) and solving the least squares problem in one ADMM step in the Fourier domain. Reconstruction results on experimentally recorded SAM and histology data show promising improvement over the classical techniques.
Collapse
|
17
|
Rohrbach D, Mamou J. Autoregressive Signal Processing Applied to High-Frequency Acoustic Microscopy of Soft Tissues. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:2054-2072. [PMID: 30222559 DOI: 10.1109/tuffc.2018.2869876] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Quantitative acoustic microscopy (QAM) at frequencies exceeding 100 MHz has become an established imaging tool to depict acoustical and mechanical properties of soft biological tissues at microscopic resolutions. In this study, we investigate a novel autoregressive (AR) model to improve signal processing and parameter estimation and to test its applicability to QAM. The performance of the AR model for estimating acoustical parameters of soft tissues (i.e., acoustic impedance, speed of sound, and attenuation) was compared to the performance of the Hozumi model using simulated ultrasonic QAM signals and using experimentally measured signals from thin (i.e., 12 and ) sections of human lymph-node and pig-cornea tissue specimens. Results showed that the AR and Hozumi methods performed equally well (i.e., produced an estimation error of 0) in signals with low, linear attenuation in the tissue and high impedance contrast between the tissue and the coupling medium. However, the AR model outperformed the Hozumi model in estimation accuracy and stability (i.e., parameter error variation and number of outliers) in cases of 1) thin tissue-sample thickness and high tissue-sample speed of sound, 2) small impedance contrast between the tissue sample and the coupling medium, 3) high attenuation in the tissue sample, and 4) nonlinear attenuation in the tissue sample. Furthermore, the AR model allows estimating the exponent of nonlinear attenuation. The results of this study suggest that the AR model approach can improve current QAM by providing more reliable, quantitative, tissue-property estimates and also provides additional values of parameters related to nonlinear attenuation.
Collapse
|
18
|
Li D, Fei C, Zhang Q, Li Y, Yang Y, Zhou Q. Ultrahigh Frequency Ultrasonic Transducers Design with Low Noise Amplifier Integrated Circuit. MICROMACHINES 2018; 9:mi9100515. [PMID: 30424448 PMCID: PMC6215185 DOI: 10.3390/mi9100515] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2018] [Revised: 10/08/2018] [Accepted: 10/08/2018] [Indexed: 02/01/2023]
Abstract
This paper describes the design of an ultrahigh frequency ultrasound system combined with tightly focused 500 MHz ultrasonic transducers and high frequency wideband low noise amplifier (LNA) integrated circuit (IC) model design. The ultrasonic transducers are designed using Aluminum nitride (AlN) piezoelectric thin film as the piezoelectric element and using silicon lens for focusing. The fabrication and characterization of silicon lens was presented in detail. Finite element simulation was used for transducer design and evaluation. A custom designed LNA circuit is presented for amplifying the ultrasound echo signal with low noise. A Common-source and Common-gate (CS-CG) combination structure with active feedback is adopted for the LNA design so that high gain and wideband performances can be achieved simultaneously. Noise and distortion cancelation mechanisms are also employed in this work to improve the noise figure (NF) and linearity. Designed by using a 0.35 μm complementary metal oxide semiconductor (CMOS) technology, the simulated power gain of the echo signal wideband amplifier is 22.5 dB at 500 MHz with a capacitance load of 1.0 pF. The simulated NF at 500 MHz is 3.62 dB.
Collapse
Affiliation(s)
- Di Li
- School of Microelectronics, Xidian University, Xi'an 710071, China.
- Department of Ophthalmology and Biomedical Engineering, University of Southern California, Los Angeles, CA 90089-1111, USA.
| | - Chunlong Fei
- School of Microelectronics, Xidian University, Xi'an 710071, China.
| | - Qidong Zhang
- School of Microelectronics, Xidian University, Xi'an 710071, China.
| | - Yani Li
- School of Microelectronics, Xidian University, Xi'an 710071, China.
| | - Yintang Yang
- School of Microelectronics, Xidian University, Xi'an 710071, China.
| | - Qifa Zhou
- Department of Ophthalmology and Biomedical Engineering, University of Southern California, Los Angeles, CA 90089-1111, USA.
| |
Collapse
|
19
|
Rohrbach D, Wodlinger B, Wen J, Mamou J, Feleppa E. High-Frequency Quantitative Ultrasound for Imaging Prostate Cancer Using a Novel Micro-Ultrasound Scanner. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:1341-1354. [PMID: 29627083 DOI: 10.1016/j.ultrasmedbio.2018.02.014] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Revised: 02/20/2018] [Accepted: 02/26/2018] [Indexed: 06/08/2023]
Abstract
Currently, biopsies guided by transrectal ultrasound (TRUS) are the only method for definitive diagnosis of prostate cancer. Studies by our group suggest that quantitative ultrasound (QUS) could provide a more sensitive means of targeting biopsies and directing focal treatments to cancer-suspicious regions in the prostate. Previous studies have utilized ultrasound signals at typical clinical frequencies, i.e., in the 6-MHz range. In the present study, a 29-MHz, TRUS, micro-ultrasound system and transducer (ExactVu micro-ultrasound, Exact Imaging, Markham, Canada) was used to acquire radio frequency data from 163 patients immediately before 12-core biopsy procedures, comprising 1956 cores. These retrospective data are a subset of data acquired in an ongoing, multisite, 2000-patient, randomized, clinical trial (clinicaltrials.gov NCT02079025). Spectrum-based QUS estimates of effective scatter diameter (ESD), effective acoustic concentration (EAC), midband (M), intercept (I) and slope (S) as well as envelope statistics employing a Nakagami distribution were used to train linear discriminant classifiers (LDCs) and support vector machines (SVMs). Classifier performance was assessed using area-under-the-curve (AUC) values obtained from receiver operating characteristic (ROC) analyses with 10-fold cross validation. A combination of ESD and EAC parameters resulted in an AUC value of 0.77 using a LDC. When Nakagami-µ or prostate-specific antigen (PSA) values were added as features, the AUC value increased to 0.79. SVM produced an AUC value of 0.77, using a combination of envelope and spectral QUS estimates. The best classification produced an AUC value of 0.81 using an LDC when combining envelope statistics, PSA, ESD and EAC. In a previous study, B-mode-based scoring and evaluation using the PRI-MUS protocol produced a maximal AUC value of 0.74 for higher Gleason-score values (GS >7) when read by an expert. Our initial results with AUC values of 0.81 are very encouraging for developing a new, predominantly user-independent, prostate-cancer, risk-assessing tool.
Collapse
Affiliation(s)
- Daniel Rohrbach
- Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY 10038, USA.
| | | | | | - Jonathan Mamou
- Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY 10038, USA
| | - Ernest Feleppa
- Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY 10038, USA
| |
Collapse
|
20
|
Rohrbach D, Silverman RH, Chun D, Lloyd HO, Urs R, Mamou J. Improved High-Frequency Ultrasound Corneal Biometric Accuracy by Micrometer-Resolution Acoustic-Property Maps of the Cornea. Transl Vis Sci Technol 2018; 7:21. [PMID: 29670830 PMCID: PMC5901370 DOI: 10.1167/tvst.7.2.21] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2017] [Accepted: 02/25/2018] [Indexed: 12/03/2022] Open
Abstract
Purpose Mapping of epithelial thickness (ET) is useful for detection of keratoconus, a disease characterized by corneal thinning and bulging in which epithelial thinning occurs over the apex. In prior clinical studies, optical coherence tomography (OCT) measurements of ET were systematically thinner than those obtained by 40-MHz high-frequency ultrasound (HFU) where a constant speed of sound (c) of 1636 m/s was used for all corneal layers. The purpose of this work was to study the acoustic properties, that is, c, acoustic impedance (Z), and attenuation (α) of the corneal epithelium and stroma independently using a scanning acoustic microscope (SAM) to investigate the discrepancy between OCT and HFU estimates of ET. Methods Twelve unfixed pig corneas were snap-frozen and 6-μm sections were scanned using a custom-built SAM with an F-1.08, 500-MHz transducer and a 264-MHz bandwidth. Two-dimensional maps of c, Z, and α with a spatial resolution of 4 μm were derived. Results SAM showed that the value of c in the epithelium (i.e., 1548 ± 18 m/s) is substantially lower than the value of c in the stroma (i.e., 1686 ± 33 m/s). Conclusion SAM results demonstrated that the assumption of a constant value of c for all corneal layers is incorrect and explains the prior discrepancy between OCT and HFU ET determinations. Translational Relevance The findings of this study have important implications for HFU-based ET measurements and will improve future keratoconus diagnosis by providing more-accurate ET estimates.
Collapse
Affiliation(s)
- Daniel Rohrbach
- Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY, USA
| | - Ronald H Silverman
- Department of Ophthalmology, Columbia University Medical Center, New York, NY, USA
| | - Dan Chun
- Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY, USA
| | - Harriet O Lloyd
- Department of Ophthalmology, Columbia University Medical Center, New York, NY, USA
| | - Raksha Urs
- Department of Ophthalmology, Columbia University Medical Center, New York, NY, USA
| | - Jonathan Mamou
- Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY, USA
| |
Collapse
|
21
|
Kim J, Mamou J, Hill PR, Canagarajah N, Kouame D, Basarab A, Achim A. Approximate Message Passing Reconstruction of Quantitative Acoustic Microscopy Images. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:327-338. [PMID: 28749347 DOI: 10.1109/tuffc.2017.2731627] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
A novel framework for compressive sensing (CS) data acquisition and reconstruction in quantitative acoustic microscopy (QAM) is presented. Three different CS patterns, adapted to the specifics of QAM systems, were investigated as an alternative to the current raster-scanning approach. They consist of diagonal sampling, a row random, and a spiral scanning pattern and can all significantly reduce both the acquisition time and the amount of sampled data. For subsequent image reconstruction, we design and implement an innovative technique, whereby a recently proposed approximate message passing method is adapted to account for the underlying data statistics. A Cauchy maximum a posteriori image denoising algorithm is thus employed to account for the non-Gaussianity of QAM wavelet coefficients. The proposed methods were tested retrospectively on experimental data acquired with a 250- or 500-MHz QAM system. The experimental data were obtained from a human lymph node sample (250 MHz) and human cornea (500 MHz). Reconstruction results showed that the best performance is obtained using a spiral sensing pattern combined with the Cauchy denoiser in the wavelet domain. The spiral sensing matrix reduced the number of spatial samples by a factor of 2 and led to an excellent peak signal-to-noise ratio of 43.21 dB when reconstructing QAM speed-of-sound images of a human lymph node. These results demonstrate that the CS approach could significantly improve scanning time, while reducing costs of future QAM systems.
Collapse
|
22
|
Rohrbach D, Ito K, Lloyd HO, Silverman RH, Yoshida K, Yamaguchi T, Mamou J. Material Properties of Human Ocular Tissue at 7-µm Resolution. ULTRASONIC IMAGING 2017; 39:313-325. [PMID: 28675987 PMCID: PMC7536713 DOI: 10.1177/0161734617713498] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Quantitative assessment of the material properties of ocular tissues can provide valuable information for investigating several ophthalmic diseases. Quantitative acoustic microscopy (QAM) offers a means of obtaining such information, but few QAM investigations have been conducted on human ocular tissue. We imaged the optic nerve (ON) and iridocorneal angle in 12-µm deparaffinized sections of the human eye using a custom-built acoustic microscope with a 250-MHz transducer (7-µm lateral resolution). The two-dimensional QAM maps of ultrasound attenuation (α), speed of sound ( c), acoustic impedance ( Z), bulk modulus ( K), and mass density (ρ) were generated. Scanned samples were then stained and imaged by light microscopy for comparison with QAM maps. The spatial resolution and contrast of scanning acoustic microscopy (SAM) maps were sufficient to resolve anatomic layers of the retina (Re); anatomic features in SAM maps corresponded to those seen by light microscopy. Significant variations of the acoustic parameters were found. For example, the sclera was 220 MPa stiffer than Re, choroid, and ON tissue. To the authors' knowledge, this is the first systematic study to assess c, Z, K, ρ, and α of human ocular tissue at the high ultrasound frequencies used in this study.
Collapse
|
23
|
Rohrbach D, Inkinen SI, Zatloukalová J, Kadow-Romacker A, Joukainen A, Malo MK, Mamou J, Töyräs J, Raum K. Regular chondrocyte spacing is a potential cause for coherent ultrasound backscatter in human articular cartilage. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2017; 141:3105. [PMID: 28599554 PMCID: PMC6909996 DOI: 10.1121/1.4979339] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2016] [Revised: 03/08/2017] [Accepted: 03/14/2017] [Indexed: 06/02/2023]
Abstract
The potential of quantitative ultrasound (QUS) to assess the regular cellular spacing in the superficial cartilage zones was investigated experimentally and numerically. Nine osteochondral samples, extracted from two human cadaver knee joints, were measured using a 50-MHz ultrasound scanning device and evaluated using Mankin score. Simulated backscattered power spectra from models with an idealized cell alignment exhibited a pronounced frequency peak. From the peak, cell spacing in the range between 15 and 40 μm between cell layers was detected with an average error of 0.2 μm. The mean QUS-based cell spacing was 28.3 ± 5.3 μm. Strong correlation (R2 = 0.59, p ≤ 0.001) between spacing estimates from light microscopy (LM) and QUS was found for samples with Mankin score ≤3. For higher scores, QUS-based spacing was significantly higher (p ≤ 0.05) compared to LM-based spacing. QUS-based spacing estimates together with other QUS parameters may serve as future biomarkers for detecting early signs of osteoarthrosis.
Collapse
Affiliation(s)
- Daniel Rohrbach
- Lizzi Center for Biomedical Engineering, Riverside Research, New York, New York 10038, USA
| | - Satu I Inkinen
- Department of Applied Physics, University of Eastern Finland, P.O. Box 1627, FI-70211, Kuopio, Finland
| | - Jana Zatloukalová
- Berlin-Brandenburg School for Regenerative Therapies, Charité-Universitätsmedizin Berlin, Augustenburger Platz, 133 53 Berlin, Germany
| | - Anke Kadow-Romacker
- Berlin-Brandenburg School for Regenerative Therapies, Charité-Universitätsmedizin Berlin, Augustenburger Platz, 133 53 Berlin, Germany
| | - Antti Joukainen
- Department of Orthopaedics, Traumatology and Hand Surgery, Kuopio University Hospital, Kuopio, Finland
| | - Markus K Malo
- Department of Applied Physics, University of Eastern Finland, P.O. Box 1627, FI-70211, Kuopio, Finland
| | - Jonathan Mamou
- Lizzi Center for Biomedical Engineering, Riverside Research, New York, New York 10038, USA
| | - Juha Töyräs
- Department of Applied Physics, University of Eastern Finland, P.O. Box 1627, FI-70211, Kuopio, Finland
| | - Kay Raum
- Berlin-Brandenburg School for Regenerative Therapies, Charité-Universitätsmedizin Berlin, Augustenburger Platz, 133 53 Berlin, Germany
| |
Collapse
|