Rahman S, Udhayakumar R, Kaplan D, McCarthy B, Dawood T, Mellor N, Senior A, Macefield VG, Buxi D, Karmakar C. Photoplethysmography as a noninvasive surrogate for microneurography in measuring stress-induced sympathetic nervous activation - A machine learning approach. Comput Biol Med 2025; 185:109522. [PMID: 39672011 DOI: 10.1016/j.compbiomed.2024.109522] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2024] [Revised: 11/21/2024] [Accepted: 12/02/2024] [Indexed: 12/15/2024]
Abstract
The sympathetic nervous system (SNS) is essential for the body's immediate response to stress, initiating physiological changes that can be measured through sympathetic nerve activity (SNA). While microneurography (MNG) is the gold standard for direct SNA measurement, its invasive nature limits its practical use in clinical settings. This study investigates the use of multi-wavelength photoplethysmography (PPG) as a non-invasive alternative for SNA measurement. Key features are extracted from the pulsatile components of red and green PPG signals to train a linear regression machine learning (ML) model to predict R-wave-triggered spike count (SPR), a biomarker derived from MNG. The study correlates PPG-derived features with ground truth SPR to develop a predictive model capable of detecting SNA during induced physical stress (isometric handgrip and cold pressor) and cognitive stress (mental arithmetic and Stroop test). Unlike previous research that relies on subjective stress indicators, our work utilizes MNG-derived SPR as an objective ground truth for validation. Our findings demonstrate strong agreement between PPG-predicted SPR values and those obtained via MNG, with red PPG showing a higher correlation. The green wavelength PPG exhibits greater sensitivity in detecting stress-induced SNA, particularly during stress onset, where it outperforms the MNG method in capturing immediate responses to stressors such as mental arithmetic and the cold pressor task. To the best of our knowledge, this is the first study to directly compare PPG-derived SNA estimates with MNG, offering a promising pathway for developing wearable, non-invasive tools for continuous stress monitoring and sympathetic arousal detection.
Collapse
Affiliation(s)
- Saifur Rahman
- School of Information Technology, Deakin University, Melbourne, Victoria, Australia
| | - Radhagayathri Udhayakumar
- School of Information Technology, Deakin University, Melbourne, Victoria, Australia; Center for Wireless Networks & Applications, Amrita Vishwa Vidyapeetham, Amritapuri, Kollam, Kerala, India
| | - David Kaplan
- Philia Labs Pty Ltd, Melbourne, Victoria, Australia
| | - Brendan McCarthy
- Baker Heart and Diabetes Institute, Melbourne, Victoria, Australia
| | - Tye Dawood
- Baker Heart and Diabetes Institute, Melbourne, Victoria, Australia
| | | | | | - Vaughan G Macefield
- Baker Heart and Diabetes Institute, Melbourne, Victoria, Australia; Monash University, Melbourne, Victoria, Australia
| | | | - Chandan Karmakar
- School of Information Technology, Deakin University, Melbourne, Victoria, Australia.
| |
Collapse
|
2
|
Khan MR, Haider ZM, Hussain J, Malik FH, Talib I, Abdullah S. Comprehensive Analysis of Cardiovascular Diseases: Symptoms, Diagnosis, and AI Innovations. Bioengineering (Basel) 2024; 11:1239. [PMID: 39768057 PMCID: PMC11673700 DOI: 10.3390/bioengineering11121239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2024] [Revised: 12/01/2024] [Accepted: 12/03/2024] [Indexed: 01/11/2025] Open
Abstract
Cardiovascular diseases are some of the underlying reasons contributing to the relentless rise in mortality rates across the globe. In this regard, there is a genuine need to integrate advanced technologies into the medical realm to detect such diseases accurately. Moreover, numerous academic studies have been published using AI-based methodologies because of their enhanced accuracy in detecting heart conditions. This research extensively delineates the different heart conditions, e.g., coronary artery disease, arrhythmia, atherosclerosis, mitral valve prolapse/mitral regurgitation, and myocardial infarction, and their underlying reasons and symptoms and subsequently introduces AI-based detection methodologies for precisely classifying such diseases. The review shows that the incorporation of artificial intelligence in detecting heart diseases exhibits enhanced accuracies along with a plethora of other benefits, like improved diagnostic accuracy, early detection and prevention, reduction in diagnostic errors, faster diagnosis, personalized treatment schedules, optimized monitoring and predictive analysis, improved efficiency, and scalability. Furthermore, the review also indicates the conspicuous disparities between the results generated by previous algorithms and the latest ones, paving the way for medical researchers to ascertain the accuracy of these results through comparative analysis with the practical conditions of patients. In conclusion, AI in heart disease detection holds paramount significance and transformative potential to greatly enhance patient outcomes, mitigate healthcare expenditure, and amplify the speed of diagnosis.
Collapse
Affiliation(s)
- Muhammad Raheel Khan
- Department of Electrical Engineering, The Islamia University of Bahawalpur, Bahawalpur 63100, Pakistan;
| | - Zunaib Maqsood Haider
- Department of Electrical Engineering, The Islamia University of Bahawalpur, Bahawalpur 63100, Pakistan;
| | - Jawad Hussain
- Department of Biomedical Engineering, Riphah College of Science and Technology, Riphah International University, Islamabad 46000, Pakistan;
| | - Farhan Hameed Malik
- Department of Electromechanical Engineering, Abu Dhabi Polytechnic, Abu Dhabi 13232, United Arab Emirates
| | - Irsa Talib
- Mechanical Engineering Department, University of Management and Technology, Lahore 45000, Pakistan;
| | - Saad Abdullah
- School of Innovation, Design and Engineering, Division of Intelligent Future Technologies, Mälardalens University, 721 23 Västerås, Sweden
| |
Collapse
|
3
|
Udhayakumar R, Gopakumar S, Rahman S, Karmakar C. Nonlinear Assessment of Gait Signal Complexity in Neurodegenerative Disorders. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2024; 2024:1-4. [PMID: 40039939 DOI: 10.1109/embc53108.2024.10781711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/06/2025]
Abstract
The human gait cycle undergoes discernible alterations upon the onset of neurodegenerative diseases (NDD) such as Parkinson's, Huntington's, and Amyotrophic lateral sclerosis. Each specific neurodegenerative disorder imparts a distinct influence on human gait dynamics, and precise quantification of these changes holds the potential for accurate methods of NDD detection.Nonlinear entropy algorithms, such as sample entropy (SampEn), find widespread use in physiological signal analysis. SampEn gauges signal complexity by identifying pattern matches within windowed sub-segments of the signal. However, traditional SampEn is notably dependent on user-defined parameters, particularly the tolerance parameter r, leading to inaccuracies in complexity information.SampEn profiling emerges as an alternative concept, eliminating the need for an input r parameter. This data-driven algorithm autonomously generates a set of 'r' values based on the signal's dynamics, yielding a comprehensive SampEn profile. The SampEn profile, containing extensive information about the signal's complexity, serves as a valuable resource for extracting secondary entropy features.In this study, we have contrasted the efficacy of traditional SampEn with SampEn profile-based secondary features such as Total SampEn (TSE) and Median SampEn (MSE), in identifying neurological states. Our findings consistently reveal that secondary features derived from the reduced-parametric SampEn profiling method outperform the traditional parametric SE in distinguishing control cohorts from specific Neurodegenerative Disease (NDD) cohorts.
Collapse
|
4
|
Ali E, Angelova M, Karmakar C. Epileptic seizure detection using CHB-MIT dataset: The overlooked perspectives. ROYAL SOCIETY OPEN SCIENCE 2024; 11:230601. [PMID: 39076791 PMCID: PMC11286169 DOI: 10.1098/rsos.230601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 11/23/2023] [Accepted: 03/28/2024] [Indexed: 07/31/2024]
Abstract
Epilepsy is a life-threatening neurological condition. Manual detection of epileptic seizures (ES) is laborious and burdensome. Machine learning techniques applied to electroencephalography (EEG) signals are widely used for automatic seizure detection. Some key factors are worth considering for the real-world applicability of such systems: (i) continuous EEG data typically has a higher class imbalance; (ii) higher variability across subjects is present in physiological signals such as EEG; and (iii) seizure event detection is more practical than random segment detection. Most prior studies failed to address these crucial factors altogether for seizure detection. In this study, we intend to investigate a generalized cross-subject seizure event detection system using the continuous EEG signals from the CHB-MIT dataset that considers all these overlooked aspects. A 5-second non-overlapping window is used to extract 92 features from 22 EEG channels; however, the most significant 32 features from each channel are used in experimentation. Seizure classification is done using a Random Forest (RF) classifier for segment detection, followed by a post-processing method used for event detection. Adopting all the above-mentioned essential aspects, the proposed event detection system achieved 72.63% and 75.34% sensitivity for subject-wise 5-fold and leave-one-out analyses, respectively. This study presents the real-world scenario for ES event detectors and furthers the understanding of such detection systems.
Collapse
Affiliation(s)
- Emran Ali
- School of Information Technology, Deakin University, Melbourne Burwood Campus, Melbourne, Victoria3125, Australia
| | - Maia Angelova
- School of Information Technology, Deakin University, Melbourne Burwood Campus, Melbourne, Victoria3125, Australia
- Aston Digital Futures Institute, EPS, Aston University, Birmingham, UK
- Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Sofia, Bulgaria
| | - Chandan Karmakar
- School of Information Technology, Deakin University, Melbourne Burwood Campus, Melbourne, Victoria3125, Australia
| |
Collapse
|
5
|
Udhayakumar R, Rahman S, Buxi D, Macefield VG, Dawood T, Mellor N, Karmakar C. Measurement of stress-induced sympathetic nervous activity using multi-wavelength PPG. ROYAL SOCIETY OPEN SCIENCE 2023; 10:221382. [PMID: 37650068 PMCID: PMC10465208 DOI: 10.1098/rsos.221382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Accepted: 08/02/2023] [Indexed: 09/01/2023]
Abstract
The onset of stress triggers sympathetic arousal (SA), which causes detectable changes to physiological parameters such as heart rate, blood pressure, dilation of the pupils and sweat release. The objective quantification of SA has tremendous potential to prevent and manage psychological disorders. Photoplethysmography (PPG), a non-invasive method to measure skin blood flow changes, has been used to estimate SA indirectly. However, the impact of various wavelengths of the PPG signal has not been investigated for estimating SA. In this study, we explore the feasibility of using various statistical and nonlinear features derived from peak-to-peak (AC) values of PPG signals of different wavelengths (green, blue, infrared and red) to estimate stress-induced changes in SA and compare their performances. The impact of two physical stressors: and Hand Grip are studied on 32 healthy individuals. Linear (Mean, s.d.) and nonlinear (Katz, Petrosian, Higuchi, SampEn, TotalSampEn) features are extracted from the PPG signal's AC amplitudes to identify the onset, continuation and recovery phases of those stressors. The results show that the nonlinear features are the most promising in detecting stress-induced sympathetic activity. TotalSampEn feature was capable of detecting stress-induced changes in SA for all wavelengths, whereas other features (Petrosian, AvgSampEn) are significant (AUC ≥ 0.8) only for IR and Red wavelengths. The outcomes of this study can be used to make device design decisions as well as develop stress detection algorithms.
Collapse
Affiliation(s)
| | - Saifur Rahman
- School of Information Technology Deakin University, Geelong 3225, Australia
| | | | | | - Tye Dawood
- Baker Heart and Diabetes Institute, Melbourne, Australia
| | | | - Chandan Karmakar
- School of Information Technology Deakin University, Geelong 3225, Australia
| |
Collapse
|
6
|
Udhayakumar R, Rahman S, Gopakumar S, Karmakar C. Nonlinear Features from Multi-Modal Signals for Continuous Stress Monitoring. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-4. [PMID: 38083095 DOI: 10.1109/embc40787.2023.10340715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Continuous monitoring of stress in individuals during their daily activities has become an inevitable need in present times. Unattended stress is a silent killer and may lead to fatal physical and mental disorders if left unidentified. Stress identification based on individual judgement often leads to under-diagnosis and delayed treatment possibilities. EEG-based stress monitoring is quite popular in this context, but impractical to use for continuous remote monitoring.Continuous remote monitoring of stress using signals acquired from everyday wearables like smart watches is the best alternative here. Non-EEG data such as heart rate and ectodermal activity can also act as indicators of physiological stress. In this work, we have explored the possibility of using nonlinear features from non-EEG data such as (a) heart rate, (b) ectodermal activity, (c) body temperature (d) SpO2 and (e) acceleration in detecting four different types of neurological states; namely (1) Relaxed state, (2) State of Physical stress, (3) State of Cognitive stress and (4) State of Emotional stress. Physiological data of 20 healthy adults have been used from the noneeg database of PhysioNet.Results: We used two machine learning models; a linear logistic regression and a nonlinear random forest to detect (a) stress from relaxed state and (4) the four different neurological states. We trained the models using linear and nonlinear features separately. For the 2-class and 4-class problems, using nonlinear features increased the accuracy of the models. Moreover, it is also proved in this study that by using nonlinear features, we can avoid the use of complex machine learning models.
Collapse
|
7
|
Sharma K, Sunkaria RK. Cardiac arrhythmia detection using cross-sample entropy measure based on short and long RR interval series. J Arrhythm 2023; 39:412-421. [PMID: 37324769 PMCID: PMC10264752 DOI: 10.1002/joa3.12839] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 01/30/2023] [Accepted: 02/23/2023] [Indexed: 06/17/2023] Open
Abstract
Background Accurate arrhythmia (atrial fibrillation (AF) and congestive heart failure (CHF)) detection is still a challenge in the biomedical signal-processing field. Different linear and nonlinear measures of the electrocardiogram (ECG) signal analysis are used to fix this problem. Methods Sample entropy (SampEn) is used as a nonlinear measure based on single series to detect healthy and arrhythmia subjects. To follow this measure, the proposed work presents a nonlinear technique, namely, the cross-sample entropy (CrossSampEn) based on two series to quantify healthy and arrhythmia subjects. Results The research work consists of 10 records of normal sinus rhythm, 20 records of Fantasia (old group), 10 records of AF, and 10 records of CHF. The method of CrossSampEn has been proposed to obtain the irregularity between two same and different R-R (R peak to peak) interval series of different data lengths. Unlike the SampEn technique, the CrossSampEn technique never awards a 'not defined' value for very short data lengths and was found to be more consistent than SampEn. One-way ANOVA test has validated the proposed algorithm by providing a large F value and p < .0001. The proposed algorithm is also verified by simulated data. Conclusions It is concluded that different RR interval series of approximate 1500 data points and same RR interval series of approximate 1000 data points are required for health-status detection with embedded dimensions, M = 2 and threshold, r = .2. Also, CrossSampEn has been found more consistent than Sample entropy algorithm.
Collapse
Affiliation(s)
- Kanchan Sharma
- Department of Electronics and Communication EngineeringDr B R Ambedkar National Institute of TechnologyJalandharPunjabIndia
| | - Ramesh Kumar Sunkaria
- Department of Electronics and Communication EngineeringDr B R Ambedkar National Institute of TechnologyJalandharPunjabIndia
| |
Collapse
|
8
|
Chou L, Gong S, Yang H, Liu J, Chou Y. A fast sample entropy for pulse rate variability analysis. Med Biol Eng Comput 2023:10.1007/s11517-022-02766-y. [PMID: 36826631 DOI: 10.1007/s11517-022-02766-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2022] [Accepted: 12/22/2022] [Indexed: 02/25/2023]
Abstract
Sample entropy is an effective nonlinear index for analyzing pulse rate variability (PRV) signal, but it has problems with a large amount of calculation and time consumption. Therefore, this study proposes a fast sample entropy calculation method to analyze the PRV signal according to the microprocessor process of data updating and the principle of sample entropy. The simulated data and PRV signal are employed as experimental data to verify the accuracy and time consumption of the proposed method. The experimental results on simulated data display that the proposed improved sample entropy can improve the operation rate of the entropy value by a maximum of 47.6 times and an average of 28.6 times and keep the entropy value unchanged. Experimental results on PRV signal display that the proposed improved sample entropy has great potential in the real-time processing of physiological signals, which can increase approximately 35 times.
Collapse
Affiliation(s)
- Lijuan Chou
- School of Electrical and Automatic Engineering, Changshu Institute of Technology, Suzhou, 215500, Jiangsu, China
- School of Computer and Information Technology, Northeast Petroleum University, Daqing, 163318, Heilongjiang, China
| | - Shengrong Gong
- School of Computer and Information Technology, Northeast Petroleum University, Daqing, 163318, Heilongjiang, China
- School of Computer Science and Engineering, Changshu Institute of Technology, Suzhou, 215500, Jiangsu, China
| | - Haiping Yang
- School of Electrical and Automatic Engineering, Changshu Institute of Technology, Suzhou, 215500, Jiangsu, China
| | - Jicheng Liu
- School of Electrical and Automatic Engineering, Changshu Institute of Technology, Suzhou, 215500, Jiangsu, China
| | - Yongxin Chou
- School of Electrical and Automatic Engineering, Changshu Institute of Technology, Suzhou, 215500, Jiangsu, China.
| |
Collapse
|
9
|
Mayor D, Steffert T, Datseris G, Firth A, Panday D, Kandel H, Banks D. Complexity and Entropy in Physiological Signals (CEPS): Resonance Breathing Rate Assessed Using Measures of Fractal Dimension, Heart Rate Asymmetry and Permutation Entropy. ENTROPY (BASEL, SWITZERLAND) 2023; 25:301. [PMID: 36832667 PMCID: PMC9955651 DOI: 10.3390/e25020301] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 01/09/2023] [Accepted: 01/21/2023] [Indexed: 06/18/2023]
Abstract
BACKGROUND As technology becomes more sophisticated, more accessible methods of interpretating Big Data become essential. We have continued to develop Complexity and Entropy in Physiological Signals (CEPS) as an open access MATLAB® GUI (graphical user interface) providing multiple methods for the modification and analysis of physiological data. METHODS To demonstrate the functionality of the software, data were collected from 44 healthy adults for a study investigating the effects on vagal tone of breathing paced at five different rates, as well as self-paced and un-paced. Five-minute 15-s recordings were used. Results were also compared with those from shorter segments of the data. Electrocardiogram (ECG), electrodermal activity (EDA) and Respiration (RSP) data were recorded. Particular attention was paid to COVID risk mitigation, and to parameter tuning for the CEPS measures. For comparison, data were processed using Kubios HRV, RR-APET and DynamicalSystems.jl software. We also compared findings for ECG RR interval (RRi) data resampled at 4 Hz (4R) or 10 Hz (10R), and non-resampled (noR). In total, we used around 190-220 measures from CEPS at various scales, depending on the analysis undertaken, with our investigation focused on three families of measures: 22 fractal dimension (FD) measures, 40 heart rate asymmetries or measures derived from Poincaré plots (HRA), and 8 measures based on permutation entropy (PE). RESULTS FDs for the RRi data differentiated strongly between breathing rates, whether data were resampled or not, increasing between 5 and 7 breaths per minute (BrPM). Largest effect sizes for RRi (4R and noR) differentiation between breathing rates were found for the PE-based measures. Measures that both differentiated well between breathing rates and were consistent across different RRi data lengths (1-5 min) included five PE-based (noR) and three FDs (4R). Of the top 12 measures with short-data values consistently within ± 5% of their values for the 5-min data, five were FDs, one was PE-based, and none were HRAs. Effect sizes were usually greater for CEPS measures than for those implemented in DynamicalSystems.jl. CONCLUSION The updated CEPS software enables visualisation and analysis of multichannel physiological data using a variety of established and recently introduced complexity entropy measures. Although equal resampling is theoretically important for FD estimation, it appears that FD measures may also be usefully applied to non-resampled data.
Collapse
Affiliation(s)
- David Mayor
- School of Health and Social Work, University of Hertfordshire, Hatfield AL10 9AB, UK
| | - Tony Steffert
- MindSpire, Napier House, 14–16 Mount Ephraim Rd., Tunbridge Wells TN1 1EE, UK
- School of Life, Health and Chemical Sciences, STEM, Walton Hall, The Open University, Milton Keynes MK7 6AA, UK
| | - George Datseris
- Department of Mathematics and Statistics, University of Exeter, North Park Road, Exeter EX4 4QF, UK
| | - Andrea Firth
- University Campus Football Business, Wembley HA9 0WS, UK
| | - Deepak Panday
- School of Engineering and Computer Science, University of Hertfordshire, Hatfield AL10 9AB, UK
| | - Harikala Kandel
- Department of Computer Science and Information Systems, Birkbeck, University of London, Malet Street, London WC1E 7HX, UK
| | - Duncan Banks
- School of Life, Health and Chemical Sciences, STEM, Walton Hall, The Open University, Milton Keynes MK7 6AA, UK
- Department of Physiology, Busitema University, Mbale P.O. Box 1966, Uganda
| |
Collapse
|
10
|
Keenan E, Karmakar CK, Udhayakumar RK, Brownfoot FC, Lakhno IV, Shulgin V, Behar JA, Palaniswami M. Detection of fetal arrhythmias in non-invasive fetal ECG recordings using data-driven entropy profiling. Physiol Meas 2022; 43. [PMID: 35073532 DOI: 10.1088/1361-6579/ac4e6d] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 01/24/2022] [Indexed: 11/11/2022]
Abstract
Objective:Fetal arrhythmias are a life-threatening disorder occurring in up to 2% of pregnancies. If identified, many fetal arrhythmias can be effectively treated using anti-arrhythmic therapies. In this paper, we present a novel method of detecting fetal arrhythmias in short length non-invasive fetal electrocardiography (NI-FECG) recordings.Approach:Our method consists of extracting a fetal heart rate (FHR) time series from each NI-FECG recording and computing an entropy profile using a data-driven range of the entropy tolerance parameter r. To validate our approach, we apply our entropy profiling method to a large clinical data set of 318 NI-FECG recordings.Main Results:We demonstrate that our method (TotalSampEn) provides strong performance for classifying arrhythmic fetuses (AUC of 0.83) and outperforms entropy measures such as SampEn (AUC of 0.68) and FuzzyEn (AUC of 0.72). We also find that NI-FECG recordings incorrectly classified using the investigated entropy measures have significantly lower signal quality, and that excluding recordings of low signal quality (13.5% of recordings) increases the classification accuracy of TotalSampEn (AUC of 0.90).Significance:The superior performance of our approach enables automated detection of fetal arrhythmias and warrants further investigation in a prospective clinical trial.
Collapse
Affiliation(s)
- Emerson Keenan
- Department of Electrical and Electronic Engineering, The University of Melbourne, Grattan Street, Melbourne, Victoria, 3010, AUSTRALIA
| | - Chandan K Karmakar
- School of Information Technology, Deakin University, 1 Gheringhap Street, Geelong, Victoria, 3220, AUSTRALIA
| | | | - Fiona Claire Brownfoot
- Department of Obstetrics and Gynaecology, The University of Melbourne, Level 4, 163 Studley Road, Heidelberg, Victoria, 3084, AUSTRALIA
| | - Igor Victorovich Lakhno
- Obstetrics and Gynecology Department, Kharkiv Medical Academy of Postgraduate Education, 58 Amosova Street, Kharkiv, 61176, UKRAINE
| | - Vyacheslav Shulgin
- Aerospace Radio-Electronic Systems Department, National Aerospace University Kharkiv Aviation Institute, 17 Chkalova Street, Kharkiv, 61000, UKRAINE
| | - Joachim Abraham Behar
- Biomedical Engineering Faculty, Technion Israel Institute of Technology, Technion City, Haifa, 3200003, ISRAEL
| | - Marimuthu Palaniswami
- Department of Electrical and Electronic Engineering, The University of Melbourne, Grattan Street, Melbourne, Victoria, 3010, AUSTRALIA
| |
Collapse
|
11
|
Li B, Jia S. Research on diagnosis method of series arc fault of three-phase load based on SSA-ELM. Sci Rep 2022; 12:592. [PMID: 35022471 PMCID: PMC8755777 DOI: 10.1038/s41598-021-04605-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Accepted: 12/28/2021] [Indexed: 11/09/2022] Open
Abstract
Arc fault in the three-phase load circuit may cause fire, resulting in production interruption and even worse, it will cause casualties. In order to effectively detect the arc fault in the three-phase circuit, series arc fault experiments of three-phase motor load and frequency converter were carried out under different current conditions. Firstly, variational mode decomposition (VMD) was performed for each cycle of A-phase current, and then the VMD energy entropy and sample entropy were calculated. Secondly, the noise-dominated component was removed according to the permutation entropy, then the average value after first-order difference of the half-cycle reconstructed signal was obtained. An arc fault diagnosis model of extreme learning machine (ELM) optimized by sparrow search algorithm (SSA) was established. The feature vectors were divided into training group and test group to train the model and test its fault diagnosis accuracy. Compared with GA-ELM, PSO-ELM, support vector machine (SVM) and SSA-SVM, the experimental results show that the proposed method can identify the series arc fault accurately and more quickly.
Collapse
Affiliation(s)
- Bin Li
- Faculty of Electrical and Control Engineering, Liaoning Technical University, Huludao, China
| | - Shihao Jia
- Faculty of Electrical and Control Engineering, Liaoning Technical University, Huludao, China.
| |
Collapse
|
12
|
Datta S, Karmakar CK, Rao AS, Yan B, Palaniswami M. Upper limb movement profiles during spontaneous motion in acute stroke. Physiol Meas 2021; 42. [PMID: 33735840 DOI: 10.1088/1361-6579/abf01e] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2020] [Accepted: 03/18/2021] [Indexed: 11/12/2022]
Abstract
Objective.The clinical assessment of upper limb hemiparesis in acute stroke involves repeated manual examination of hand movements during instructed tasks. This process is labour-intensive and prone to human error as well as being strenuous for the patient. Wearable motion sensors can automate the process by measuring characteristics of hand activity. Existing work in this direction either uses multiple sensors or complex instructed movements, or analyzes only thequantityof upper limb motion. These methods are obtrusive and strenuous for acute stroke patients and are also sensitive to noise. In this work, we propose to use only two wrist-worn accelerometer sensors to study thequalityof completely spontaneous upper limb motion and investigate correlation with clinical scores for acute stroke care.Approach.The velocity time series estimated from acquired acceleration data during spontaneous motion is decomposed into smaller movement elements. Measures of density, duration and smoothness of these component elements are extracted and their disparity is studied across the two hands.Main results.Spontaneous upper limb motion in acute stroke can be decomposed into movement elements that resemble point-to-point reaching tasks. These elements are smoother and sparser in the normal hand than in the hemiparetic hand, and the amount of smoothness correlates with hemiparetic severity. Features characterizing the disparity of these movement elements between the two hands show statistical significance in differentiating mild-to-moderate and severe hemiparesis. Using data from 67 acute stroke patients, the proposed method can classify the two levels of hemiparetic severity with 85% accuracy. Additionally, compared to activity-based features, the proposed method is robust to the presence of noise in acquired data.Significance.This work demonstrates that the quality of upper limb motion can characterize and identify hemiparesis in stroke survivors. This is clinically significant towards the continuous automated assessment of hemiparesis in acute stroke using minimally intrusive wearable sensors.
Collapse
Affiliation(s)
- Shreyasi Datta
- Department of Electrical and Electronic Engineering, University of Melbourne, Melbourne, Australia
| | - Chandan K Karmakar
- School of Information Technology, Deakin University, Melbourne, Australia
| | - Aravinda S Rao
- Department of Electrical and Electronic Engineering, University of Melbourne, Melbourne, Australia
| | - Bernard Yan
- Department of Neurology, Royal Melbourne Hospital, Melbourne, Australia
| | - Marimuthu Palaniswami
- Department of Electrical and Electronic Engineering, University of Melbourne, Melbourne, Australia
| |
Collapse
|
13
|
Zhan J, Wu ZX, Duan ZX, Yang GY, Du ZY, Bao XH, Li H. Heart rate variability-derived features based on deep neural network for distinguishing different anaesthesia states. BMC Anesthesiol 2021; 21:66. [PMID: 33653263 PMCID: PMC7923817 DOI: 10.1186/s12871-021-01285-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2020] [Accepted: 02/17/2021] [Indexed: 11/25/2022] Open
Abstract
Background Estimating the depth of anaesthesia (DoA) is critical in modern anaesthetic practice. Multiple DoA monitors based on electroencephalograms (EEGs) have been widely used for DoA monitoring; however, these monitors may be inaccurate under certain conditions. In this work, we hypothesize that heart rate variability (HRV)-derived features based on a deep neural network can distinguish different anaesthesia states, providing a secondary tool for DoA assessment. Methods A novel method of distinguishing different anaesthesia states was developed based on four HRV-derived features in the time and frequency domain combined with a deep neural network. Four features were extracted from an electrocardiogram, including the HRV high-frequency power, low-frequency power, high-to-low-frequency power ratio, and sample entropy. Next, these features were used as inputs for the deep neural network, which utilized the expert assessment of consciousness level as the reference output. Finally, the deep neural network was compared with the logistic regression, support vector machine, and decision tree models. The datasets of 23 anaesthesia patients were used to assess the proposed method. Results The accuracies of the four models, in distinguishing the anaesthesia states, were 86.2% (logistic regression), 87.5% (support vector machine), 87.2% (decision tree), and 90.1% (deep neural network). The accuracy of deep neural network was higher than those of the logistic regression (p < 0.05), support vector machine (p < 0.05), and decision tree (p < 0.05) approaches. Our method outperformed the logistic regression, support vector machine, and decision tree methods. Conclusions The incorporation of four HRV-derived features in the time and frequency domain and a deep neural network could accurately distinguish between different anaesthesia states; however, this study is a pilot feasibility study. The proposed method—with other evaluation methods, such as EEG—is expected to assist anaesthesiologists in the accurate evaluation of the DoA. Supplementary Information The online version contains supplementary material available at 10.1186/s12871-021-01285-x.
Collapse
Affiliation(s)
- Jian Zhan
- Department of Anaesthesiology, The Second Affiliated Hospital of Army Medical University, Chongqing, 400037, China.,Department of Anaesthesiology, The Affiliated Hospital of Southwest Medical University, Luzhou, 646000, Sichuan, China
| | - Zhuo-Xi Wu
- Department of Anaesthesiology, The Second Affiliated Hospital of Army Medical University, Chongqing, 400037, China
| | - Zhen-Xin Duan
- Department of Anaesthesiology, The Second Affiliated Hospital of Army Medical University, Chongqing, 400037, China
| | - Gui-Ying Yang
- Department of Anaesthesiology, The Second Affiliated Hospital of Army Medical University, Chongqing, 400037, China
| | - Zhi-Yong Du
- Department of Anaesthesiology, The Second Affiliated Hospital of Army Medical University, Chongqing, 400037, China
| | - Xiao-Hang Bao
- Department of Anaesthesiology, The Second Affiliated Hospital of Army Medical University, Chongqing, 400037, China
| | - Hong Li
- Department of Anaesthesiology, The Second Affiliated Hospital of Army Medical University, Chongqing, 400037, China.
| |
Collapse
|
14
|
Liang D, Wu S, Tang L, Feng K, Liu G. Short-Term HRV Analysis Using Nonparametric Sample Entropy for Obstructive Sleep Apnea. ENTROPY 2021; 23:e23030267. [PMID: 33668394 PMCID: PMC7996273 DOI: 10.3390/e23030267] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 01/12/2021] [Accepted: 01/13/2021] [Indexed: 12/14/2022]
Abstract
Obstructive sleep apnea (OSA) is associated with reduced heart rate variability (HRV) and autonomic nervous system dysfunction. Sample entropy (SampEn) is commonly used for regularity analysis. However, it has limitations in processing short-term segments of HRV signals due to the extreme dependence of its functional parameters. We used the nonparametric sample entropy (NPSampEn) as a novel index for short-term HRV analysis in the case of OSA. The manuscript included 60 6-h electrocardiogram recordings (20 healthy, 14 mild-moderate OSA, and 26 severe OSA) from the PhysioNet database. The NPSampEn value was compared with the SampEn value and frequency domain indices. The empirical results showed that NPSampEn could better differentiate the three groups (p < 0.01) than the ratio of low frequency power to high frequency power (LF/HF) and SampEn. Moreover, NPSampEn (83.3%) approached a higher OSA screening accuracy than the LF/HF (73.3%) and SampEn (68.3%). Compared with SampEn (|r| = 0.602, p < 0.05), NPSampEn (|r| = 0.756, p < 0.05) had a significantly stronger association with the apnea-hypopnea index (AHI). Hence, NPSampEn can fully overcome the influence of individual differences that are prevalent in biomedical signal processing, and might be useful in processing short-term segments of HRV signal.
Collapse
Affiliation(s)
- Duan Liang
- School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou 510275, China; (D.L.); (S.W.); (L.T.); (K.F.)
- Key Laboratory of Sensing Technology and Biomedical Instruments of Guangdong Province, School of Engineering, Sun Yat-Sen University, Guangzhou 510275, China
- Guangdong Provincial Engineering and Technology Centre of Advanced and Portable Medical Device, Guangzhou 510006, China
| | - Shan Wu
- School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou 510275, China; (D.L.); (S.W.); (L.T.); (K.F.)
- Key Laboratory of Sensing Technology and Biomedical Instruments of Guangdong Province, School of Engineering, Sun Yat-Sen University, Guangzhou 510275, China
- Guangdong Provincial Engineering and Technology Centre of Advanced and Portable Medical Device, Guangzhou 510006, China
| | - Lan Tang
- School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou 510275, China; (D.L.); (S.W.); (L.T.); (K.F.)
- Key Laboratory of Sensing Technology and Biomedical Instruments of Guangdong Province, School of Engineering, Sun Yat-Sen University, Guangzhou 510275, China
- Guangdong Provincial Engineering and Technology Centre of Advanced and Portable Medical Device, Guangzhou 510006, China
| | - Kaicheng Feng
- School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou 510275, China; (D.L.); (S.W.); (L.T.); (K.F.)
- Key Laboratory of Sensing Technology and Biomedical Instruments of Guangdong Province, School of Engineering, Sun Yat-Sen University, Guangzhou 510275, China
- Guangdong Provincial Engineering and Technology Centre of Advanced and Portable Medical Device, Guangzhou 510006, China
| | - Guanzheng Liu
- School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou 510275, China; (D.L.); (S.W.); (L.T.); (K.F.)
- Key Laboratory of Sensing Technology and Biomedical Instruments of Guangdong Province, School of Engineering, Sun Yat-Sen University, Guangzhou 510275, China
- Guangdong Provincial Engineering and Technology Centre of Advanced and Portable Medical Device, Guangzhou 510006, China
- Correspondence:
| |
Collapse
|
15
|
Karmakar C, Udhayakumar R, Palaniswami M. Entropy Profiling: A Reduced-Parametric Measure of Kolmogorov-Sinai Entropy from Short-Term HRV Signal. ENTROPY (BASEL, SWITZERLAND) 2020; 22:E1396. [PMID: 33321962 PMCID: PMC7763921 DOI: 10.3390/e22121396] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Revised: 12/08/2020] [Accepted: 12/08/2020] [Indexed: 11/20/2022]
Abstract
Entropy profiling is a recently introduced approach that reduces parametric dependence in traditional Kolmogorov-Sinai (KS) entropy measurement algorithms. The choice of the threshold parameter r of vector distances in traditional entropy computations is crucial in deciding the accuracy of signal irregularity information retrieved by these methods. In addition to making parametric choices completely data-driven, entropy profiling generates a complete profile of entropy information as against a single entropy estimate (seen in traditional algorithms). The benefits of using "profiling" instead of "estimation" are: (a) precursory methods such as approximate and sample entropy that have had the limitation of handling short-term signals (less than 1000 samples) are now made capable of the same; (b) the entropy measure can capture complexity information from short and long-term signals without multi-scaling; and (c) this new approach facilitates enhanced information retrieval from short-term HRV signals. The novel concept of entropy profiling has greatly equipped traditional algorithms to overcome existing limitations and broaden applicability in the field of short-term signal analysis. In this work, we present a review of KS-entropy methods and their limitations in the context of short-term heart rate variability analysis and elucidate the benefits of using entropy profiling as an alternative for the same.
Collapse
Affiliation(s)
- Chandan Karmakar
- School of Information Technology, Deakin University, Geelong VIC 3216, Australia;
| | | | - Marimuthu Palaniswami
- Department of Electrical & Electronic Engineering, The University of Melbourne, Parkville VIC 3010, Australia;
| |
Collapse
|
16
|
Keenan E, Udhayakumar RK, Karmakar CK, Brownfoot FC, Palaniswami M. Entropy Profiling for Detection of Fetal Arrhythmias in Short Length Fetal Heart Rate Recordings. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:621-624. [PMID: 33018064 DOI: 10.1109/embc44109.2020.9175892] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The use of fetal heart rate (FHR) recordings for assessing fetal wellbeing is an integral component of obstetric care. Recently, non-invasive fetal electrocardiography (NI-FECG) has demonstrated utility for accurately diagnosing fetal arrhythmias via clinician interpretation. In this work, we introduce the use of data-driven entropy profiling to automatically detect fetal arrhythmias in short length FHR recordings obtained via NI-FECG. Using an open access dataset of 11 normal and 11 arrhythmic fetuses, our method (TotalSampEn) achieves excellent classification performance (AUC = 0.98) for detecting fetal arrhythmias in a short time window (i.e. under 10 minutes). We demonstrate that our method outperforms SampEn (AUC = 0.72) and FuzzyEn (AUC = 0.74) based estimates, proving its effectiveness for this task. The rapid detection provided by our approach may enable efficient triage of concerning FHR recordings for clinician review.
Collapse
|
17
|
Suppressing the Influence of Ectopic Beats by Applying a Physical Threshold-Based Sample Entropy. ENTROPY 2020; 22:e22040411. [PMID: 33286185 PMCID: PMC7516878 DOI: 10.3390/e22040411] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Revised: 03/31/2020] [Accepted: 04/01/2020] [Indexed: 11/17/2022]
Abstract
Sample entropy (SampEn) is widely used for electrocardiogram (ECG) signal analysis to quantify the inherent complexity or regularity of RR interval time series (i.e., heart rate variability (HRV)), with the hypothesis that RR interval time series in pathological conditions output lower SampEn values. However, ectopic beats can significantly influence the entropy values, resulting in difficulty in distinguishing the pathological situation from normal situations. Although a theoretical operation is to exclude the ectopic intervals during HRV analysis, it is not easy to identify all of them in practice, especially for the dynamic ECG signal. Thus, it is important to suppress the influence of ectopic beats on entropy results, i.e., to improve the robustness and stability of entropy measurement for ectopic beats-inserted RR interval time series. In this study, we introduced a physical threshold-based SampEn method, and tested its ability to suppress the influence of ectopic beats for HRV analysis. An experiment on the PhysioNet/MIT RR Interval Databases showed that the SampEn use physical meaning threshold has better performance not only for different data types (normal sinus rhythm (NSR) or congestive heart failure (CHF) recordings), but also for different types of ectopic beat (atrial beats, ventricular beats or both), indicating that using a physical meaning threshold makes SampEn become more consistent and stable.
Collapse
|
18
|
Udhayakumar RK, Karmakar C, Palaniswami M. Cross Entropy Profiling to Test Pattern Synchrony in Short-Term Signals. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:737-740. [PMID: 31946002 DOI: 10.1109/embc.2019.8857272] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Examining nonlinear bi-variate time series for pattern synchrony has been largely carried out by the cross sample entropy measure, X-SampEn, which is highly bound by parametric restrictions. Threshold parameter r is the one that limits X-SampEn estimations most adversely. An inappropriate r choice leads to erroneous synchrony detection, even for the case of X-SampEn analysis on simple synthetically generated signals like the MIX(P) process. This gives us an intimation of how difficult it would be for such synchrony measures to handle the more complex physiologic data. The recently introduced concept of entropy profiling has been proved to release such measures from the clutches of r dependence. In this study, we demonstrate how entropy profiling with respect to r can be implemented on cross entropy analysis, particularly X-SampEn. We have used different sets of simple MIX(P) processes for the purpose and validated the impact of X-SampEn profiling over X-SampEn estimation, with a special focus on short-term data. From results, we see that X-SampEn profiling alone can accurately classify MIX(P) signals based on pattern synchrony. Here, X-SampEn estimation fails undoubtedly, even at the higher data lengths where traditional SampEn estimation is known to perform with good accuracy.
Collapse
|
19
|
Udhayakumar RK, Karmakar C, Palaniswami M. Entropy Profiling to Detect ST Change in Heart Rate Variability Signals. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:4588-4591. [PMID: 31946886 DOI: 10.1109/embc.2019.8857297] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Elevation or depression in an electrocardiographic ST segment is an important indication of cardiac Ischemia. Computer-aided algorithms have been proposed in the recent past for the detection of ST change in ECG signals. Such algorithms are accompanied by difficulty in locating a functional ST segment from the ECG. Laborious signal processing tasks have to be carried out in order to precisely locate the start and end of an ST segment. In this work, we propose to detect ST change from heart rate variability (HRV) or RR-interval signals, rather than the ECG itself. Since HRV analysis does not require ST segment localization, we hypothesize an easier and more accurate automated ST change detection here. We use the recent concept of entropy profiling to detect ST change from RR interval data, where the estimation corresponds to irregularity information contained in the respective signals. We have compared results of SampEn, FuzzyEn and TotalSampEn (entropy profiling) on 18 normal and 28 ST-changed RR interval signals. SampEn and FuzzyEn give maximum AUCs of 0.64 and 0.62 respectively, at the data length N = 750. T otalSampEn shows a maximum AUC of 0.92 at N = 50, clearly proving its effectiveness on short-term signals and an AUC of 0.88 at N = 750, proving its efficiency over SampEn and F uzzyEn.
Collapse
|
20
|
A New Physically Meaningful Threshold of Sample Entropy for Detecting Cardiovascular Diseases. ENTROPY 2019. [PMCID: PMC7515359 DOI: 10.3390/e21090830] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Sample Entropy (SampEn) is a popular method for assessing the regularity of physiological signals. Prior to the entropy calculation, certain common parameters need to be initialized: Embedding dimension m, tolerance threshold r and time series length N. Nevertheless, the determination of these parameters is usually based on expert experience. Improper assignments of these parameters tend to bring invalid values, inconsistency and low statistical significance in entropy calculation. In this study, we proposed a new tolerance threshold with physical meaning (rp), which was based on the sampling resolution of physiological signals. Statistical significance, percentage of invalid entropy values and ROC curve were used to evaluate the proposed rp against the traditional threshold (rt). Normal sinus rhythm (NSR), congestive heart failure (CHF) as well as atrial fibrillation (AF) RR interval recordings from Physionet were used as the test data. The results demonstrated that the proposed rp had better stability than rt, hence more adaptive to detect cardiovascular diseases of CHF and AF.
Collapse
|
21
|
Udhayakumar RK, Karmakar C, Palaniswami M. Multiscale entropy profiling to estimate complexity of heart rate dynamics. Phys Rev E 2019; 100:012405. [PMID: 31499811 DOI: 10.1103/physreve.100.012405] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2019] [Indexed: 06/10/2023]
Abstract
In the analysis of signal regularity from a physiological system such as the human heart, Approximate entropy (H_{A}) and Sample entropy (H_{S}) have been the most popular statistical tools used so far. While studying heart rate dynamics, it nevertheless becomes more important to extract information about complexities associated with the heart, rather than the regularity of signal patterns produced by it. A complex physiological system does not necessarily produce irregular signals and vice versa. In order to equip a regularity statistic to see through the respective system's level of complexity, the idea of multiscaling was introduced in H_{S} estimation. Multiscaling ideally requires an input signal to be (a) long and (b) stationary. However, the longer the data is the less stationary it is. The requirement multiscaling places on its data length largely limits its accuracy. We propose a novel method of entropy profiling that makes multiscaling require very short signal segments, granting better prospects of signal stationarity and estimation accuracy. With entropy profiling, an efficient multiscale H_{S} based analysis requires only 500-beat signals of atrial fibrillated data, as opposed to the earlier case that required at least 20 000 beats.
Collapse
Affiliation(s)
- Radhagayathri K Udhayakumar
- Department of Electrical and Electronic Engineering, The University of Melbourne, Melbourne VIC 3010, Australia
| | - Chandan Karmakar
- Department of Electrical and Electronic Engineering, The University of Melbourne, Melbourne VIC 3010, Australia
- School of Information Technology, Deakin University, Burwood VIC 3125, Australia
| | - Marimuthu Palaniswami
- Department of Electrical and Electronic Engineering, The University of Melbourne, Melbourne VIC 3010, Australia
| |
Collapse
|