1
|
Talukder A, Jo J. Elastic textile-based wearable modulation of musculoskeletal load: A comprehensive review of passive exosuits and resistance clothing. WEARABLE TECHNOLOGIES 2025; 6:e11. [PMID: 40071238 PMCID: PMC11894418 DOI: 10.1017/wtc.2025.2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/27/2024] [Revised: 01/07/2025] [Accepted: 01/22/2025] [Indexed: 03/14/2025]
Abstract
Elastic textiles play a critical role in passive wearable solutions for musculoskeletal load management in both passive exosuits and resistance clothing. These textiles, based on their ability to stretch and retract, can exhibit ambivalence in their load-modulating effects when used in occupational, rehabilitation, exercise, or everyday activity settings. While passive exosuits and resistance garments may appear similar in design, they have opposing goals: to reduce the musculoskeletal load in the case of exosuits and to increase it in the case of resistance clothing. Despite this intrinsic connection, these two approaches have not been extensively linked together. This review aims to fill this gap by examining the common and distinct principles of elastic textiles in passive exosuits and resistance clothing, shedding light on their interactions and the complex dynamics of musculoskeletal load systems. The effectiveness of different designs in passive exosuits that mimic musculoskeletal function and resistance clothing that increase the workload for strength training are critically reviewed. Current challenges in practical implementation and opportunities to improve critical issues, such as preload, thermal comfort, skin friction, and donning and doffing are also highlighted.
Collapse
Affiliation(s)
- Amit Talukder
- Department of Textiles, Merchandising, and Interiors, University of Georgia, Athens, GA, USA
| | - Jeyeon Jo
- Department of Textiles, Merchandising, and Interiors, University of Georgia, Athens, GA, USA
| |
Collapse
|
2
|
Zhang X, Zhang L, Sun Y, Li T, Zhou M. Quantitative assessment of biceps brachii muscle stiffness by using Young’s modulus–Angle curve during passive stretching in stroke patients. Front Physiol 2023; 14:907337. [PMID: 36969599 PMCID: PMC10030944 DOI: 10.3389/fphys.2023.907337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Accepted: 02/20/2023] [Indexed: 03/10/2023] Open
Abstract
Purpose: This study aims to use shear wave elastography (SWE) to dynamically describe the characteristics of biceps brachii muscle stiffness during passive stretching in healthy participants, investigate changes in the Young’s modulus–angle curve under various states of muscle tone in stroke patients, and develop a new method for measuring muscle tone quantitatively.Methods: In total, 30 healthy volunteers and 54 stroke patients were evaluated for elbow flexor muscle tone on both sides using passive motion examination and were divided into groups based on their muscle tone status. The real-time SWE video of the biceps brachii and the Young’s modulus data were recorded during the passive straightening of the elbow. The Young’s modulus–elbow angle curves were created and fitted using an exponential model. The parameters yielded from the model were subjected to further intergroup analysis.Results: The repeatability of the Young’s modulus measurement was generally good. During passive elbow extension, the Young’s modulus of the biceps brachii steadily increased as muscle tone increased, and it increased faster when the modified Ashworth scale (MAS) score got higher. The exponential model’s fitness was generally good. The curvature coefficient was significantly different between the MAS 0 group and the hypertonia groups (MAS 1, 1+, and 2 groups).Conclusion: The passive elastic characteristics of the biceps brachii are consistent with the exponential model. The Young’s modulus–elbow angle curve of the biceps brachii changes in distinct ways depending on the muscle tone status. SWE can be used to quantify muscular stiffness during passive stretching as a new way of muscle tone evaluation, allowing for quantitative muscle tone evaluation and mathematical assessment of muscle mechanical properties in stroke patients.
Collapse
Affiliation(s)
- Xinpei Zhang
- Department of Rehabilitation Medicine, Peking University Third Hospital, Beijing, China
| | - Li Zhang
- Department of Ultrasound, Peking University Third Hospital, Beijing, China
| | - Yang Sun
- Department of Ultrasound, Peking University Third Hospital, Beijing, China
| | - Tao Li
- Department of Rehabilitation Medicine, Peking University Third Hospital, Beijing, China
| | - Mouwang Zhou
- Department of Rehabilitation Medicine, Peking University Third Hospital, Beijing, China
- *Correspondence: Mouwang Zhou,
| |
Collapse
|
3
|
Deng M, Zhou L, Chen Z, Yuan G, Zhou Y, Xiao Y. An ex-vivo validation of the modulus-length framework to characterize passive elastic properties of skeletal muscle. ULTRASONICS 2023; 129:106904. [PMID: 36463727 DOI: 10.1016/j.ultras.2022.106904] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2021] [Revised: 09/09/2022] [Accepted: 11/24/2022] [Indexed: 06/17/2023]
Abstract
The passive elastic properties of skeletal muscles are related closely to muscle extensibility and flexibility. Recently, a single probe setup has been reported that measures the passive elastic properties of muscles in vivo. This uses a modulus-length framework to investigate sensitive dynamic parameters, termed as passive elastic coefficient k, slack length l0, and slack shear modulus G0 to quantify the passive elastic properties of human muscle. In particular, the parameter k calculated based on this framework reflects the change rate of the local shear modulus with respect to the muscle length, which remains constant during the entire passive stretching process. In this report, the modulus-length framework was validated in four groups of ex-vivo muscle samples (young and old chickens, pork, and beef). All the muscle samples were stretched mechanically whilst muscle length was monitored and recorded with simultaneous measurement of dynamic shear wave elastography (SWE). Agreement analyses using Bland-Altman diagrams and intraclass correlation coefficients (ICC) were then performed on coefficient k values obtained by mechanical stretching (k1) and real-time ultrasound imaging methods (k2). Bland-Altman diagrams show that the majority of the points lie within the 95 % LoA ([-1.87, 2.29]; p = 0.276) and the level of reliability was "good" to "excellent" based on the ICC results (ICC, 0.904; 95 % confidence interval, 0.813-0.953). This indicated that the ultrasound and mechanical methods produced very similar results. Meanwhile, the range of the coefficient k values in four muscle types and groups was significantly different (p < 0.05), a finding which strongly supports the potential use of this coefficient to characterize muscle quality and status.
Collapse
Affiliation(s)
- Miaoqin Deng
- School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, China; Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Liying Zhou
- Department of Obstetrics and Gynecology, Shenzhen Longhua District Central Hospital, Guangdong Medical University Affiliated Longhua District Central Hospital, Shenzhen, China
| | - Zengtong Chen
- School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, China
| | - Guojian Yuan
- School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, China
| | - Yongjin Zhou
- School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, China; Marshall Laboratory of Biomedical Engineering, Shenzhen University, Shenzhen, China
| | - Yang Xiao
- National Innovation Center For Advanced Medical Devices, Shenzhen National Research Institute of High Performance Medical Devices Co, Ltd, Shenzhen, China
| |
Collapse
|
4
|
Xiao Y, Wang C, Pan M, Chen Z, Ma T, Zhou Y, Liu X. Ultrasonic characterization of localized passive elastic properties of human pennate muscle with a single-probe setup. ULTRASONICS 2021; 116:106512. [PMID: 34274743 DOI: 10.1016/j.ultras.2021.106512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Revised: 06/09/2021] [Accepted: 06/30/2021] [Indexed: 06/13/2023]
Abstract
Quantitative evaluation of passive elastic properties of an individual skeletal muscle in vivo is among the major challenges of biomechanics, and its clinical application is severely limited. By combining shear-wave elastography (SWE) and B-mode imaging techniques, this study develops a novel non-invasive method to measure the local elastic modulus-fascicle strain curve of human pennation muscle during passive stretching using a single probe. Physiologically meaningful parameters are estimated and compared in subjects with different ages or pathological conditions. The in vivo experimental group comprised 12 healthy subjects (four children, four adults, and four seniors) and eight patients (four suffering from pseudohypertrophy, four from atrophy). Their gastrocnemius muscles were passively stretched using an ankle joint motion instrument. Local elastic moduli of the muscle were measured using SWE imaging frames and a built-in 'F-ROI' tool. The corresponding fascicle strains were simultaneously obtained using B-mode imaging frames and a gradient Radon transform. Three parameters (η, μ, G0) were estimated from a normalized elastic modulus-strain curve using the Gauss-Newton method. The measured elastic modulus-strain curves all agreed with models of the estimated parameters (0.910 < R2 < 0.999) and presented different patterns among normal and diseased subjects. η values were lower for pseudohypertrophies (1.93 ± 0.12), but higher for atrophies (63.40 ± 98.89), compared with normal ones (6.02 ± 2.53). In addition, μ values were higher for pseudohypertrophies (22.65 ± 16.40), but lower for atrophies (0.28 ± 0.41), compared with normal ones (1.07 ± 1.22). The proposed method may provide novel insight into the biomechanics of pennate muscle and has the potential to serve for clinical musculoskeletal medical diagnosis, as the single-probe scanning setup is broadly accepted.
Collapse
Affiliation(s)
- Yang Xiao
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Congzhi Wang
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Min Pan
- Department of Ultrasonography, Shenzhen Hospital of Guangzhou University of Chinese Medicine, Shenzhen 518034, China
| | - Zengtong Chen
- School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen 518055, China; Marshall Laboratory of Biomedical Engineering, China
| | - Teng Ma
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Yongjin Zhou
- School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen 518055, China; Marshall Laboratory of Biomedical Engineering, China
| | - Xiao Liu
- Department of Ultrasonography, Shenzhen Hospital of Guangzhou University of Chinese Medicine, Shenzhen 518034, China
| |
Collapse
|
5
|
Yin L, Du L, Li Y, Xiao Y, Zhang S, Ma H, He W. Quantitative Evaluation of Gastrocnemius Medialis Stiffness During Passive Stretching Using Shear Wave Elastography in Patients with Parkinson's Disease: A Prospective Preliminary Study. Korean J Radiol 2021; 22:1841-1849. [PMID: 34431245 PMCID: PMC8546131 DOI: 10.3348/kjr.2020.1338] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2020] [Revised: 05/31/2021] [Accepted: 06/01/2021] [Indexed: 01/11/2023] Open
Abstract
Objective To prospectively investigate the feasibility of shear wave elastography (SWE) as a new quantitative and objective method for evaluating the stiffness of the gastrocnemius medialis (GM) muscle during passive stretching in patients with Parkinson's disease (PD). Materials and Methods SWE of the GM muscle was performed in 28 patients with PD [13 female and 15 male; mean age ± standard deviation (SD): 63.0 ± 8.5 years] and 12 healthy controls (5 female and 7 male; mean age ± SD: 59.3 ± 6.4 years) during passive ankle rotation. A Young's modulus-ankle angle curve was constructed. The GM slack angle and baseline Young's modulus (E0) were compared between the markedly symptomatic and mildly symptomatic sides of patients with PD, and healthy controls. Additionally, the correlation between the GM slack angle and the severity of rigidity, and the observer reproducibility of SWE in determining the GM slack angle were evaluated. Results The GM slack angle was smaller on both the markedly and mildly symptomatic sides in patients with PD than in healthy controls (mean ± SD of −29.13° ± 3.79° and −25.65° ± 3.39°, respectively, vs. −21.22° ± 3.52°; p < 0.001 and p = 0.006, respectively). Additionally, in patients with PD, the GM slack angle on the markedly symptomatic side was smaller than that on the mildly symptomatic side (p = 0.003). The E0 value was lower on both the markedly and mildly symptomatic sides in patients with PD than in healthy controls (mean ± SD of 10.11 ± 2.85 kPa and 10.08 ± 1.88 kPa, respectively, vs. 12.23 ± 1.02 kPa; p = 0.012 and p < 0.001, respectively). However, no significant difference was found between the markedly and mildly symptomatic sides in patients with PD (p = 0.634). A negative linear relationship was observed between the GM slack angle and lower limb rigidity score on the markedly symptomatic side in patients with PD (r = −0.719; p < 0.001). The intraclass correlation coefficients for observer reproducibility of SWE ranged from 0.880 to 0.951. Conclusion The slack angle determined by SWE may be a useful quantitative and reproducible method for evaluating muscle stiffness in patients with PD.
Collapse
Affiliation(s)
- Lu Yin
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Lijuan Du
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Yuanzi Li
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Yang Xiao
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Shiquan Zhang
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Huizi Ma
- Center for Movement Disorders, Department of Neurology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Wen He
- Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
| |
Collapse
|