1
|
Dong F, Wu Y, Li W, Li X, Zhou J, Wang B, Chen M. Advancements in microwave ablation for tumor treatment and future directions. iScience 2025; 28:112175. [PMID: 40271529 PMCID: PMC12017980 DOI: 10.1016/j.isci.2025.112175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/25/2025] Open
Abstract
Microwave ablation (MWA) is a minimally invasive treatment that uses thermal energy to target and destroy tumors. Compared to other ablation methods, such as radiofrequency ablation (RFA), MWA operates at higher frequencies, allowing for faster ablation and larger treatment areas. In addition to its direct tumor-destroying effects, MWA has been shown to activate immune responses, contributing to long-term antitumor effects. MWA can also be combined with surgery, chemotherapy, and immunotherapy to enhance treatment outcomes. This review examines the current research on MWA's technical innovations, clinical applications, and its potential in improving cancer treatment efficacy.
Collapse
Affiliation(s)
- Fangying Dong
- Emergency Department, the Second Affiliated Hospital of Jiaxing University, Jiaxing, Zhejiang, China
| | - Yijie Wu
- General Practice, Taozhuang Branch of the First People’s Hospital of Jiashan, Jiaxing, Zhejiang, China
| | - Weiwei Li
- Emergency Department, the Second Affiliated Hospital of Jiaxing University, Jiaxing, Zhejiang, China
| | - Xiaoping Li
- Department of Surgery, the Second Affiliated Hospital of Jiaxing University, Jiaxing, Zhejiang, China
| | - Jing Zhou
- Department of Surgery, the Second Affiliated Hospital of Jiaxing University, Jiaxing, Zhejiang, China
| | - Bin Wang
- Department of General Practice, the Second Affiliated Hospital of Jiaxing University, Jiaxing, Zhejiang, China
| | - Minjie Chen
- Department of Surgery, the Second Affiliated Hospital of Jiaxing University, Jiaxing, Zhejiang, China
| |
Collapse
|
2
|
Wu C, Huang H, Liu Y, Chen L, Yu S, Moser MAJ, Zhang W, Fang Z, Zhang B. Optimal design of aperiodic tri-slot antennas for the conformal ablation of liver tumors using an experimentally validated MWA computer model. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 242:107799. [PMID: 37703699 DOI: 10.1016/j.cmpb.2023.107799] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 09/03/2023] [Accepted: 09/03/2023] [Indexed: 09/15/2023]
Abstract
OBJECTIVE This study aims to demonstrate that the conformal microwave ablation (MWA) of liver tumors could be attained by optimizing the structure of an aperiodic tri-slot coaxial antenna, its insertion depth, and input power. METHODS A computational MWA model with an aperiodic tri-slot coaxial antenna operating at the frequency of 2.45 GHz was built and validated by both an ex vivo and a pilot in vivo experiment with porcine healthy livers. The validated in vivo computational MWA model implemented with a liver tumor was then used as a testbed to investigate the conformal ablation of liver tumors. Five liver tumors in different sizes and shapes were investigated. A genetic algorithm optimization method (NSGA-II) was used to optimize the structure of antenna, insertion depth of antenna, and microwave antenna input power for the conformal ablation of liver tumors. RESULTS The validation results showed that a good agreement in both the spatiotemporal temperature distribution and ablation zone was found between the computer model and the ex vivo experiments at both 45 W, 5 min and 60 W, 3 min treatments and the in vivo experiment at 45 W, 5 min treatment. The optimized simulation results confirmed that five cases of liver tumors in different sizes and shapes can be conformally ablated by optimizing the aperiodic tri-slot coaxial antenna, antenna insertion depth, and microwave antenna input power. CONCLUSION This paper demonstrates that the aperiodic tri-slot coaxial antenna can be optimized with the insertion depth and input power for the conformal ablation of liver tumors, regardless the size and shape of liver tumors.
Collapse
Affiliation(s)
- Chen Wu
- Intelligent Energy-based Tumor Ablation Laboratory, School of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200444, China
| | - Hangming Huang
- Intelligent Energy-based Tumor Ablation Laboratory, School of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200444, China
| | - Yongfang Liu
- Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201412, China
| | - Lingchao Chen
- Department of Neurosurgery, Huashan Hospital Shanghai Medical College, Fudan University, Shanghai 200040, China
| | - Shuangquan Yu
- Department of Neurosurgery, Huashan Hospital Shanghai Medical College, Fudan University, Shanghai 200040, China
| | - Michael A J Moser
- Department of Surgery, University of Saskatchewan, Saskatoon, Canada
| | - Wenjun Zhang
- Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, Canada
| | - Zheng Fang
- Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, Canada.
| | - Bing Zhang
- Intelligent Energy-based Tumor Ablation Laboratory, School of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200444, China.
| |
Collapse
|
3
|
Singh SK, Yadav AN. Novel tumor localization model and prediction of ablation zone using an intertwined helical antenna for the treatment of hepatocellular carcinoma. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3686. [PMID: 36690467 DOI: 10.1002/cnm.3686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 01/05/2023] [Accepted: 01/14/2023] [Indexed: 05/12/2023]
Abstract
Hepatocellular carcinoma has been the leading cause of death in recent centuries and with the advent of newer technologies, several thermal and cryo-ablation techniques have been introduced in the recent past. In this regard, microwave ablation has developed into a promising method for thermal ablation technique. However, due to clinical obligations, in-vivo analysis is not feasible and ex-vivo analysis is inaccurate due to changes in the electrical and thermal properties of the tissue. Therefore, in this study, temperature-dependent permittivity, electrical conductivity, and thermal conductivity along with phase change effect due to temperature reaching above 100°C are incorporated using finite element method model. Further, using an intertwined normal mode helical antenna ablation probe, a change in resonant frequency (Δf) and reflection coefficient (ΔS11 ) from the actual value (antenna parameter in the air at 5 GHz) is modeled using second-order polynomial curve fitting to predict the surrounding permittivity in the range of 30-70. A maximum deviation of 0.8 value in permittivity from the actual value is observed. However, to obtain a generalized methodology, XG Boost and CAT Boost algorithms are used. Further, since ablation diameter plays a crucial role in achieving optimal tumor ablation, an artificial neural network (ANN) algorithm with three different optimizers is incorporated to predict ablation diameter using five critical parameters. Such an ANN algorithm which can predict the transversal and axial ablation zone may provide optimal ablation outcomes.
Collapse
Affiliation(s)
- Suyash Kumar Singh
- Electronics and Communication Engineering Department, Indian Institute of Information Technology, Allahabad, India
| | - Amar Nath Yadav
- Electronics and Communication Engineering Department, Indian Institute of Information Technology, Allahabad, India
| |
Collapse
|
4
|
Singla A, Marwaha A, Marwaha S. Multi-criterion optimization of invasive antenna applicators for Au@Fe 3O4, Au@-Fe 2O 3 and Au@-Fe 2O 3 mediated microwave ablation treatment. Electromagn Biol Med 2023; 42:21-40. [PMID: 36857381 DOI: 10.1080/15368378.2023.2184381] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2023]
Abstract
Magnetic nanoparticle (MNP) mediated microwave ablation has the great potential at present to address challenges associated with treatment planning such as maximum heat generation in the vicinity of targeted tissues in lesser penetration time. Further, the antenna applicators injected in human phantom must be rigid and thin. The derivative-free optimization algorithms are carried out for optimum design of monopole, slot, dipole, and tapered slot antenna applicators for ablation of tumour tissues invasively. It is found that in terms of input impedance matching, the used multi-criterion Nelder-Mead optimization performs efficiently for tapered slot applicator achieving S11 value of -40 dB with much reduced antenna dimensions. In order to further escalate the performance of tapered slot antenna, gold (Au)-coated iron-based MNPs are suggested for tumor infusion. Spherical gold-coated shell material is preferrable for more sphericity of ablation zone, biocompatibility and due to high conductivity, heat generated in MNPs can be transferred to biological tissues more rapidly. The size, type, and shape of MNPs also influence the heat generation in tumor tissues. Thus, three different types of MNPs having high magnetization properties, Au@Fe3O4, Au@α-Fe2O3 and Au@γ-Fe2O3 have been employed to study the performance in terms of maximum rise in temperature, specific absorption rate (SAR), and area of ablation zone by varying core size radius of MNPs. Results demonstrate that increase in radius of MNP core helps in increasing the temperature distribution and reduction in ablation zone. The optimized lesion is achieved for 20 nm core radius of Au@Fe3O4.
Collapse
Affiliation(s)
- Alka Singla
- Electronics and Communication Engineering Department, SLIET Longowal, Sangrur, India
| | - Anupma Marwaha
- Electronics and Communication Engineering Department, SLIET Longowal, Sangrur, India
| | - Sanjay Marwaha
- Electrical and Instrumentation Engineering Department, SLIET Longowal, Sangrur, India
| |
Collapse
|
5
|
Miaskowski A, Gas P. Numerical Estimation of SAR and Temperature Distributions inside Differently Shaped Female Breast Tumors during Radio-Frequency Ablation. MATERIALS (BASEL, SWITZERLAND) 2022; 16:223. [PMID: 36614561 PMCID: PMC9821952 DOI: 10.3390/ma16010223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/19/2022] [Revised: 12/22/2022] [Accepted: 12/23/2022] [Indexed: 06/17/2023]
Abstract
Radio-frequency (RF) ablation is a reliable technique for the treatment of deep-seated malignant tumors, including breast carcinoma, using high ablative temperatures. The paper aims at a comparative analysis of the specific absorption rate and temperature distribution during RF ablation with regard to different female breast tumors. In the study, four tumor models equivalent to an irregular tumor were considered, i.e., an equivalent sphere and ellipsoid with the same surfaces and volumes as the irregular tumor and an equivalent sphere and ellipsoid inscribed in the irregular tumor. An RF applicator with a specific voltage, operating at 100 kHz inserted into the anatomically correct female breast, was applied as a source of electromagnetically induced heat. A conjugated Laplace equation with the modified Pennes equation was used to obtain the appropriate temperature gradient in the treated area. The levels of power dissipation in terms of the specific absorption rate (SAR) inside the naturalistically shaped tumor, together with the temperature profiles of the four simplified tumor models equivalent to the irregular one, were determined. It was suggested that the equivalent tumor models might successfully replace a real, irregularly shaped tumor, and the presented numeric methodology may play an important role in the complex therapeutic RF ablation process of irregularly shaped female breast tumors.
Collapse
Affiliation(s)
- Arkadiusz Miaskowski
- Department of Applied Mathematics and Computer Sciences, Faculty of Production Engineering, University of Life Sciences in Lublin, Akademicka 13 Street, 20-950 Lublin, Poland
| | - Piotr Gas
- Department of Electrical and Power Engineering, Faculty of Electrical Engineering, Automatics, Computer Science and Biomedical Engineering, AGH University of Science and Technology, Mickiewicza 30 Avenue, 30-059 Krakow, Poland
| |
Collapse
|
6
|
Dai Q, Cao B, Zhao S, Zhang A. Synergetic Thermal Therapy for Cancer: State-of-the-Art and the Future. Bioengineering (Basel) 2022; 9:bioengineering9090474. [PMID: 36135020 PMCID: PMC9495761 DOI: 10.3390/bioengineering9090474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 09/01/2022] [Accepted: 09/05/2022] [Indexed: 11/24/2022] Open
Abstract
As a safe and minimal-invasive modality, thermal therapy has become an effective treatment in cancer treatment. Other than killing the tumor cells or destroying the tumor entirely, the thermal modality results in profound molecular, cellular and biological effects on both the targeted tissue, surrounding environments, and even the whole body, which has triggered the combination of the thermal therapy with other traditional therapies as chemotherapy and radiation therapy or new therapies like immunotherapy, gene therapy, etc. The combined treatments have shown encouraging therapeutic effects both in research and clinic. In this review, we have summarized the outcomes of the existing synergistic therapies, the underlying mechanisms that lead to these improvements, and the latest research in the past five years. Limitations and future directions of synergistic thermal therapy are also discussed.
Collapse
|
7
|
Abstract
Microwave thermal ablation was developed as an alternative to other forms of thermal ablation procedures. The objective of this study is to numerically model a microwave ablation probe operating at the 2.45 GHz level using the finite element and finite volume methods to provide a comprehensive and repeatable study within a human male approximately 25 to 30 years old. The three-dimensional physical model included a human liver along with the surrounding tissues and bones. Three different input powers (10, 20, and 30 watts) were studied, along with the effect of the probe’s internal coolant flow rate. One of the primary results from the numerical simulations was the extent of affected tissue from the microwave probe. The resulting time and temperature results were used to predict tissue damage using an injury integral method. The numerical approach was validated with available experimental data and was found to be within 6% of the average experimentally measured temperatures.
Collapse
|