1
|
Brites CDS. Enlightening molecular logic: basics, tools and techniques for newcomers. MATERIALS HORIZONS 2025. [PMID: 40145338 DOI: 10.1039/d5mh00192g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/28/2025]
Abstract
As silicon-based technologies approach their physical limits, the search for alternative computing paradigms becomes imperative. Molecular logic has emerged as a promising approach, particularly the systems based on trivalent lanthanide ions that exploit the unique photophysical properties of these ions to implement Boolean logic operations. This focus article provides a comprehensive introduction to the principles, methodologies, and recent advancements in luminescence-driven molecular computing. Designed for newcomers, it outlines the fundamental concepts, essential experimental techniques, and standardized protocols for characterizing luminescent molecular logic devices. The advantages of these devices, such as energy efficiency, multiplexing capabilities, and adaptability to complex environments, are also critically examined. Addressing some limitations of traditional electronics, molecular logic paves the way for innovative applications in diagnostics, sensing, and novel computational architectures, offering a transformative and sustainable pathway for next-generation information processing.
Collapse
Affiliation(s)
- Carlos D S Brites
- Phantom-G, Department of Physics, CICECO-Aveiro Institute of Materials, University of Aveiro, Campus Universitário de Santiago, Aveiro, Portugal.
| |
Collapse
|
2
|
Halder RS, Basumatary B, Sahani A. Development of a low-cost, compact, wireless, 16 - channel biopotential data acquisition, signal conditioning and arbitrary waveform stimulator. Biomed Phys Eng Express 2024; 10:025002. [PMID: 38118179 DOI: 10.1088/2057-1976/ad17a8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Accepted: 12/20/2023] [Indexed: 12/22/2023]
Abstract
The health and fitness of the human body rely heavily on physiological parameters. These parameters can be measured using various tools such as ECG, EMG, EEG, EOG, among others, to obtain real-time physiological data. Analysing the bio-signals obtained from these measurements can provide valuable information that can be used to improve health-care in terms of observation, diagnosis, and treatment. In bio-signal pattern recognition applications, more channels provide multiple information simultaneously. Different biosignal acquisition devices are available in the market, most of which are designed for specific signals like ECG, EMG, EEG etc The gain of the amplifiers and frequency of the filters are designed as per the targeted signals; due to which one device cannot be used for other signals. Also, most of the systems are wired system which is not comfortable for animal studies. In this paper, a low-cost, compact, wireless, 16 channel biopotential data acquisition system with integrated electrical stimulator is designed and implemented. There are several novel and flexible design approaches were incorporated in the proposed design like (1) It has user selectable digital filter in each channel based on the signal frequencies like ECG, EMG, EEG, EOG. The same system will be used to acquire different signals simultaneously. (2) It has variable gain with a configurable analog bandpass filter. (3) It can acquire signals from 4 patients simultaneously. (4) The system is capable to acquire signal from both two-electrode as well as three-electrode configurations. (5) It has integrated stimulator with trapezoidal, charge-balanced, biphasic stimulus output with near zero DC level and user selectable pulse duration or frequency of the stimulus. The developed system has the ability to acquire and transmit data wirelessly in real-time at a high transfer rate. To validate the performance of the system, tests were conducted on the acquired signals using a simulator.
Collapse
Affiliation(s)
- Rajat Suvra Halder
- Department of Biomedical Engineering, Indian Institute of Technology, Ropar, India
| | - Bijit Basumatary
- Department of Biomedical Engineering, Indian Institute of Technology, Ropar, India
| | - Ashish Sahani
- Department of Biomedical Engineering, Indian Institute of Technology, Ropar, India
| |
Collapse
|
3
|
|
4
|
Azdad N, Elboukhari M. Wireless Body Area Networks for Healthcare. INTERNATIONAL JOURNAL OF BUSINESS DATA COMMUNICATIONS AND NETWORKING 2021. [DOI: 10.4018/ijbdcn.286702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Motivated by the increasing need for improved healthcare solutions, Wireless Body Area Networks (WBANs) have shown their great potential in revolutionizing the next generation healthcare through enabling continuous monitoring of health status with early detection of abnormal situations. Such networks are able to support a diverse range of applications with traffic rates ranging from several bits per hour up to 10 megabits per second. For the efficient functionality of these applications, each one poses a specific set of Quality of Service (QoS) requirements to the Medium Access Control (MAC) sub-layer including transmission reliability, timeliness and throughput. However, energy limitations of WBANs make the satisfaction of these requirements a challenging task. The current paper aims to explore the application trends of WBANs in the health field as well as the salient features of the MAC protocols proposed for this class of networks, and to provide a general rule indicating the most suitable MAC technology for WBANs based on the characteristics of the targeted application.
Collapse
Affiliation(s)
- Nabila Azdad
- MATSI Laboratory, ESTO, Mohammed First University, Oujda, Morocco
| | | |
Collapse
|
5
|
Ersöz A, Kim I, Han M. Maximizing Charge Injection Limits of Iridium Oxide Electrodes with a Programmable Anodic Bias Circuit. INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING : [PROCEEDINGS]. INTERNATIONAL IEEE EMBS CONFERENCE ON NEURAL ENGINEERING 2021; 2021:540-543. [PMID: 34925702 PMCID: PMC8674787 DOI: 10.1109/ner49283.2021.9441282] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Efficacious stimulation of neural tissues requires high charge injection capacity while minimizing electrode polarization. Applying anodic bias on certain electrode materials is a way to enhance charge injection both in vitro and in vivo. We developed an embedded neurostimulator system that enabled a digital control of user-defined bias levels, without requiring a potentiometer or external voltage source. Comparison of charge injection with and without anodic-bias, as well as at different bias potentials were conducted in phosphate-buffered saline with Blackrock iridium oxide microelectrodes. Results showed that a nine-fold increase in current intensity and charge injection capacity, was achieved with a 0.7 V anodic bias and within electrochemically safe limits.
Collapse
Affiliation(s)
- Alpaslan Ersöz
- Biomedical Engineering Department, University of Connecticut, Storrs, CT 06269 USA
| | - Insoo Kim
- Department of Medicine and Division of Occupational and Environmental Medicine, University of Connecticut, Farmington, CT 06030 USA
| | - Martin Han
- Biomedical Engineering Department, University of Connecticut, Storrs, CT 06269 USA
| |
Collapse
|
6
|
Di Rienzo M, Rizzo G, Işilay ZM, Lombardi P. SeisMote: A Multi-Sensor Wireless Platform for Cardiovascular Monitoring in Laboratory, Daily Life, and Telemedicine. SENSORS (BASEL, SWITZERLAND) 2020; 20:E680. [PMID: 31991918 PMCID: PMC7038355 DOI: 10.3390/s20030680] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Revised: 01/20/2020] [Accepted: 01/24/2020] [Indexed: 02/05/2023]
Abstract
This article presents a new wearable platform, SeisMote, for the monitoring of cardiovascular function in controlled conditions and daily life. It consists of a wireless network of sensorized nodes providing simultaneous multiple measures of electrocardiogram (ECG), acceleration, rotational velocity, and photoplethysmogram (PPG) from different body areas. A custom low-power transmission protocol was developed to allow the concomitant real-time monitoring of 32 signals (16 bit @200 Hz) from up to 12 nodes with a jitter in the among-node time synchronization lower than 0.2 ms. The BluetoothLE protocol may be used when only a single node is needed. Data can also be collected in the off-line mode. Seismocardiogram and pulse transit times can be derived from the collected data to obtain additional information on cardiac mechanics and vascular characteristics. The employment of the system in the field showed recordings without data gaps caused by transmission errors, and the duration of each battery charge exceeded 16 h. The system is currently used to investigate strategies of hemodynamic regulation in different vascular districts (through a multisite assessment of ECG and PPG) and to study the propagation of precordial vibrations along the thorax. The single-node version is presently exploited to monitor cardiac patients during telerehabilitation.
Collapse
Affiliation(s)
- Marco Di Rienzo
- IRCCS Fondazione Don Carlo Gnocchi, 20148 Milano, Italy; (G.R.); (Z.M.I.); (P.L.)
| | | | | | | |
Collapse
|
7
|
Martinez D, Clément M, Messaoudi B, Gervasoni D, Litaudon P, Buonviso N. Adaptive quantization of local field potentials for wireless implants in freely moving animals: an open-source neural recording device. J Neural Eng 2019; 15:025001. [PMID: 29219118 DOI: 10.1088/1741-2552/aaa041] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Modern neuroscience research requires electrophysiological recording of local field potentials (LFPs) in moving animals. Wireless transmission has the advantage of removing the wires between the animal and the recording equipment but is hampered by the large number of data to be sent at a relatively high rate. APPROACH To reduce transmission bandwidth, we propose an encoder/decoder scheme based on adaptive non-uniform quantization. Our algorithm uses the current transmitted codeword to adapt the quantization intervals to changing statistics in LFP signals. It is thus backward adaptive and does not require the sending of side information. The computational complexity is low and similar at the encoder and decoder sides. These features allow for real-time signal recovery and facilitate hardware implementation with low-cost commercial microcontrollers. MAIN RESULTS As proof-of-concept, we developed an open-source neural recording device called NeRD. The NeRD prototype digitally transmits eight channels encoded at 10 kHz with 2 bits per sample. It occupies a volume of 2 × 2 × 2 cm3 and weighs 8 g with a small battery allowing for 2 h 40 min of autonomy. The power dissipation is 59.4 mW for a communication range of 8 m and transmission losses below 0.1%. The small weight and low power consumption offer the possibility of mounting the entire device on the head of a rodent without resorting to a separate head-stage and battery backpack. The NeRD prototype is validated in recording LFPs in freely moving rats at 2 bits per sample while maintaining an acceptable signal-to-noise ratio (>30 dB) over a range of noisy channels. SIGNIFICANCE Adaptive quantization in neural implants allows for lower transmission bandwidths while retaining high signal fidelity and preserving fundamental frequencies in LFPs.
Collapse
Affiliation(s)
- Dominique Martinez
- Laboratoire Lorrain de Recherche en Informatique et ses Applications (LORIA), Centre National de la Recherche Scientifique (CNRS), UMR7503, Vandœuvre-lès-Nancy, France
| | | | | | | | | | | |
Collapse
|
8
|
Mahajan R, Morshed BI, Bidelman GM. BRAINsens: Body-Worn Reconfigurable Architecture of Integrated Network Sensors. J Med Syst 2018; 42:185. [PMID: 30167826 DOI: 10.1007/s10916-018-1036-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2018] [Accepted: 08/20/2018] [Indexed: 10/28/2022]
Abstract
Body sensor network (BSN) is a promising human-centric technology to monitor neurophysiological data. We propose a fully-reconfigurable architecture that addresses the major challenges of a heterogenous BSN, such as scalabiliy, modularity and flexibility in deployment. Existing BSNs especially with Electroencephalogarm (EEG) have these limitations mainly due to the use of driven-right-leg (DRL) circuit. We address these limitations by custom-designing DRL-less EEG smart sensing nodes (SSN) for modular and spatially distributed systems. Each single-channel EEG SSN with a input-referred noise of 0.82 μVrms and CMRR of 70 dB (at 60 Hz), samples brain signals at 512 sps. SSNs in the network can be configured at the time of deployment and can process information locally to significantly reduce data payload of the network. A Control Command Node (CCN) initializes, synchronizes, periodically scans for the available SSNs in the network, aggregates their data and sends it wirelessly to a paired device at a baud rate of 115.2 kbps. At the given settings of the I2C bus speed of 100 kbps, CCN can configure up to 39 EEG SSNs in a lego-like platform. The temporal and frequency-domain performance of the designed "DRL-less" EEG SSNs is evaluated against a research-grade Neuroscan and consumer-grade Emotiv EPOC EEG. The results show that the proposed network system with wearable EEG can be deployed in situ for continuous brain signal recording in real-life scenarios. The proposed system can also seamlessly incorporate other physiological SSNs for ECG, HRV, temperature etc. along with EEG within the same topology.
Collapse
Affiliation(s)
- Ruhi Mahajan
- Center for Biomedical Informatics, University of Tennessee Health Science Center, Memphis, TN, USA.
| | - Bashir I Morshed
- Department of Electrical and Computer Engineering, University of Memphis, Memphis, TN, USA
| | - Gavin M Bidelman
- School of Communication Sciences & Disorders, University of Memphis, Memphis, TN, USA
| |
Collapse
|
9
|
Alam MM, Ben Hamida E. Strategies for Optimal MAC Parameters Tuning in IEEE 802.15.6 Wearable Wireless Sensor Networks. J Med Syst 2015; 39:106. [DOI: 10.1007/s10916-015-0277-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2015] [Accepted: 07/13/2015] [Indexed: 10/23/2022]
|
10
|
|
11
|
Alam MM, Ben Hamida E. Surveying wearable human assistive technology for life and safety critical applications: standards, challenges and opportunities. SENSORS (BASEL, SWITZERLAND) 2014; 14:9153-209. [PMID: 24859024 PMCID: PMC4063029 DOI: 10.3390/s140509153] [Citation(s) in RCA: 134] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2014] [Revised: 04/25/2014] [Accepted: 05/14/2014] [Indexed: 11/26/2022]
Abstract
In this survey a new application paradigm life and safety for critical operations and missions using wearable Wireless Body Area Networks (WBANs) technology is introduced. This paradigm has a vast scope of applications, including disaster management, worker safety in harsh environments such as roadside and building workers, mobile health monitoring, ambient assisted living and many more. It is often the case that during the critical operations and the target conditions, the existing infrastructure is either absent, damaged or overcrowded. In this context, it is envisioned that WBANs will enable the quick deployment of ad-hoc/on-the-fly communication networks to help save many lives and ensuring people's safety. However, to understand the applications more deeply and their specific characteristics and requirements, this survey presents a comprehensive study on the applications scenarios, their context and specific requirements. It explores details of the key enabling standards, existing state-of-the-art research studies, and projects to understand their limitations before realizing aforementioned applications. Application-specific challenges and issues are discussed comprehensively from various perspectives and future research and development directions are highlighted as an inspiration for new innovative solutions. To conclude, this survey opens up a good opportunity for companies and research centers to investigate old but still new problems, in the realm of wearable technologies, which are increasingly evolving and getting more and more attention recently.
Collapse
Affiliation(s)
- Muhammad Mahtab Alam
- Qatar Mobility Innovations Center (QMIC), Qatar Science and Technology Park (QSTP), PO Box 210531, Doha, Qatar.
| | - Elyes Ben Hamida
- Qatar Mobility Innovations Center (QMIC), Qatar Science and Technology Park (QSTP), PO Box 210531, Doha, Qatar.
| |
Collapse
|
12
|
An automatic weighting system for wild animals based in an artificial neural network: how to weigh wild animals without causing stress. SENSORS 2013; 13:2862-83. [PMID: 23449117 PMCID: PMC3658719 DOI: 10.3390/s130302862] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/17/2012] [Revised: 02/22/2013] [Accepted: 02/25/2013] [Indexed: 11/17/2022]
Abstract
This paper proposes a novel and autonomous weighing system for wild animals. It allows evaluating changes in the body weight of animals in their natural environment without causing stress. The proposed system comprises a smart scale designed to estimate individual body weights and their temporal evolution in a bird colony. The system is based on computational intelligence, and offers valuable large amount of data to evaluate the relationship between long-term changes in the behavior of individuals and global change. The real deployment of this system has been for monitoring a breeding colony of lesser kestrels (Falco naumanni) in southern Spain. The results show that it is possible to monitor individual weight changes during the breeding season and to compare the weight evolution in males and females.
Collapse
|
13
|
Niederhauser T, Marisa T, Haeberlin A, Goette J, Jacoment M, Vogel R. High-resolution esophageal long-term ECG allows detailed atrial wave morphology analysis in case of atrial ectopic beats. Med Biol Eng Comput 2012; 50:769-72. [PMID: 22610727 DOI: 10.1007/s11517-012-0915-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2012] [Accepted: 05/03/2012] [Indexed: 10/28/2022]
Abstract
Detection of arrhythmic atrial beats in surface ECGs can be challenging when they are masked by the R or T wave, or do not affect the RR-interval. Here, we present a solution using a high-resolution esophageal long-term ECG that offers a detailed view on the atrial electrical activity. The recorded ECG shows atrial ectopic beats with long coupling intervals, which can only be successfully classified using additional morphology criteria. Esophageal high-resolution ECGs provide this information, whereas surface long-term ECGs show poor atrial signal quality. This new method is a promising tool for the long-term rhythm monitoring with software-based automatic classification of atrial beats.
Collapse
|
14
|
Wang WS, Huang HY, Wu ZC, Chen SC, Wang WF, Wu CF, Luo CH. Wireless biopotential acquisition system for portable healthcare monitoring. J Med Eng Technol 2011; 35:254-61. [PMID: 21619420 DOI: 10.3109/03091902.2011.580038] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
A complete biopotential acquisition system with an analogue front-end (AFE) chip is proposed for portable healthcare monitoring. A graphical user interface (GUI) is also implemented to display the extracted biopotential signals in real-time on a computer for patients or in a hospital via the internet for doctors. The AFE circuit defines the quality of the acquired biosignals. Thus, an AFE chip with low power consumption and a high common-mode rejection ratio (CMRR) was implemented in the TSMC 0.18-μm CMOS process. The measurement results show that the proposed AFE, with a core area of 0.1 mm(2), has a CMRR of 90 dB, and power consumption of 21.6 μW. Biopotential signals of electroencephalogram (EEG), electrocardiogram (ECG) and electromyogram (EMG) were measured to verify the proposed system. The board size of the proposed system is 6 cm × 2.5 cm and the weight is 30 g. The total power consumption of the proposed system is 66 mW.
Collapse
Affiliation(s)
- W-S Wang
- Department of Electrical Engineering, National Cheng Kung University, Tainan, Taiwan
| | | | | | | | | | | | | |
Collapse
|
15
|
Manzi de Arantes W, Verdier C. Defining quality-measurable medical alerts from incomplete data through fuzzy linguistic variables and modifiers. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE : A PUBLICATION OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY 2010; 14:916-922. [PMID: 19369164 DOI: 10.1109/titb.2009.2020063] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Alert systems are frequent in the medical field, where they are typically connected to monitoring devices that are able to detect abnormal values. Our system is different in its goals and tools. First of all, it processes data extracted from electronic medical records, which are widely used nowadays, and meteorological databases. Variables that are not continually measured by devices (like the age of patients) can then be taken into account. Next, the alerts it handles are not predefined, but created by users through domain-independent fuzzy linguistic variables whose relationships (the height of an individual is conditioned by its age) are modeled by a weighted oriented graph. Finally, the alerts it triggers are associated with two indicators used for filtering and assessing their relevance to the patients, and their reliability according to the amount of information available. Then, if there is a missing variable in a record, the detection algorithm treats it transparently by automatically decreasing the reliability of the alert. The main qualities of this system are the simplicity--linguistic variables are intuitive--and the ability to measure the informational quality of alerts (applicability and reliability).
Collapse
|
16
|
Sharma V, McCreery DB, Han M, Pikov V. Bidirectional telemetry controller for neuroprosthetic devices. IEEE Trans Neural Syst Rehabil Eng 2009; 18:67-74. [PMID: 19933010 DOI: 10.1109/tnsre.2009.2036849] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
We present versatile multifunctional programmable controller with bidirectional data telemetry, implemented using existing commercial microchips and standard Bluetooth protocol, which adds convenience, reliability, and ease-of-use to neuroprosthetic devices. Controller, weighing 190 g, is placed on animal's back and provides bidirectional sustained telemetry rate of 500 kb/s , allowing real-time control of stimulation parameters and viewing of acquired data. In continuously-active state, controller consumes approximately 420 mW and operates without recharge for 8 h . It features independent 16-channel current-controlled stimulation, allowing current steering; customizable stimulus current waveforms; recording of stimulus voltage waveforms and evoked neuronal responses with stimulus artifact blanking circuitry. Flexibility, scalability, cost-efficiency, and a user-friendly computer interface of this device allow use in animal testing for variety of neuroprosthetic applications. Initial testing of the controller has been done in a feline model of brainstem auditory prosthesis. In this model, the electrical stimulation is applied to the array of microelectrodes implanted in the ventral cochlear nucleus, while the evoked neuronal activity was recorded with the electrode implanted in the contralateral inferior colliculus. Stimulus voltage waveforms to monitor the access impedance of the electrodes were acquired at the rate of 312 kilosamples/s. Evoked neuronal activity in the inferior colliculus was recorded after the blanking (transient silencing) of the recording amplifier during the stimulus pulse, allowing the detection of neuronal responses within 100 mus after the end of the stimulus pulse applied in the cochlear nucleus.
Collapse
Affiliation(s)
- Vishnu Sharma
- Neural Engineering Program, Huntington Medical Research Institutes, Pasadena, CA 91105, USA. vishnu_vds@yahoo
| | | | | | | |
Collapse
|
17
|
Uceda JD, Elena M, Blasco S, Tarrida CL, Quero JM. IMS: a new technology to develop a telemedicine system. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2009; 2008:767-70. [PMID: 19162768 DOI: 10.1109/iembs.2008.4649265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The emergent IMS (Internet Protocol Multimedia Subsystem) technology appears to improve the current communication technologies. Its characteristics, such as Quality of Service (QoS), make it an advantageous system for innovative applications. Providing integrated services to users is one of the main reasons for the existence of IMS. Operators provide the technology as an open source, to be able to use services developed by researchers. Combining and integrating them, users will receive completely new services. Our proposal of use for IMS is the development of a telemedicine platform, designed to support not only remote biological signal monitoring, but value-added services for diagnosis and medical care, both of these working in real time.
Collapse
Affiliation(s)
- J D Uceda
- Electronic Engineering Department, University of Seville, Seville, 41092, Spain
| | | | | | | | | |
Collapse
|