1
|
Cui J, Hollingsworth NA, Wright SM. A Review of Current Control and Decoupling Methods for MRI Transmit Arrays. IEEE Rev Biomed Eng 2025; 18:388-400. [PMID: 38194402 DOI: 10.1109/rbme.2024.3351713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2024]
Abstract
The shortened radio frequency wavelength in high field MRI makes it challenging to create a uniform excitation pattern over a large field of view, or to achieve satisfactory transmission efficiency at a local area. Transmit arrays are one tool that can be used to create a desired excitation pattern. To be effective, it is important to be able to control the current amplitude and phase at the array elements. The control of the current may get complicated by the coil coupling in many applications. Various methods have been proposed to achieve current control, either in the presence of coupling, or by effectively decouple the array elements. These methods are applied in different subsystems in the RF transmission chain: coil; coil-amplifier interface; amplifier, etc. In this review paper, we provide an overview of the various approaches and aspects of transmit current control and decoupling.
Collapse
|
2
|
Zhou Q, Fan S, Lei KM, Ham D, Martins RP, Mak PI. Miniature Magnetic Resonance Imaging System for in situ Monitoring of Bacterial Growth and Biofilm Formation. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2024; 18:990-1000. [PMID: 38393852 DOI: 10.1109/tbcas.2024.3369389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/25/2024]
Abstract
In situ monitoring of bacterial growth can greatly benefit human healthcare, biomedical research, and hygiene management. Magnetic resonance imaging (MRI) offers two key advantages in tracking bacterial growth: non-invasive monitoring through opaque sample containers and no need for sample pretreatment such as labeling. However, the large size and high cost of conventional MRI systems are the roadblocks for in situ monitoring. Here, we proposed a small, portable MRI system by combining a small permanent magnet and an integrated radio-frequency (RF) electronic chip that excites and reads out nuclear spin motions in a sample, and utilize this small MRI platform for in situ imaging of bacterial growth and biofilm formation. We demonstrate that MRI images taken by the miniature--and thus broadly deployable for in situ work--MRI system provide information on the spatial distribution of bacterial density, and a sequential set of MRI images taken at different times inform the temporal change of the spatial map of bacterial density, showing bacterial growth.
Collapse
|
3
|
Murali S, Ding H, Adedeji F, Qin C, Obungoloch J, Asllani I, Anazodo U, Ntusi NAB, Mammen R, Niendorf T, Adeleke S. Bringing MRI to low- and middle-income countries: Directions, challenges and potential solutions. NMR IN BIOMEDICINE 2024; 37:e4992. [PMID: 37401341 DOI: 10.1002/nbm.4992] [Citation(s) in RCA: 16] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2022] [Revised: 05/27/2023] [Accepted: 05/30/2023] [Indexed: 07/05/2023]
Abstract
The global disparity of magnetic resonance imaging (MRI) is a major challenge, with many low- and middle-income countries (LMICs) experiencing limited access to MRI. The reasons for limited access are technological, economic and social. With the advancement of MRI technology, we explore why these challenges still prevail, highlighting the importance of MRI as the epidemiology of disease changes in LMICs. In this paper, we establish a framework to develop MRI with these challenges in mind and discuss the different aspects of MRI development, including maximising image quality using cost-effective components, integrating local technology and infrastructure and implementing sustainable practices. We also highlight the current solutions-including teleradiology, artificial intelligence and doctor and patient education strategies-and how these might be further improved to achieve greater access to MRI.
Collapse
Affiliation(s)
- Sanjana Murali
- School of Medicine, Faculty of Medicine, Imperial College London, London, UK
| | - Hao Ding
- School of Medicine, Faculty of Medicine, Imperial College London, London, UK
| | - Fope Adedeji
- School of Medicine, Faculty of Medicine, University College London, London, UK
| | - Cathy Qin
- Department of Imaging, Imperial College Healthcare NHS Trust, London, UK
| | - Johnes Obungoloch
- Department of Biomedical Engineering, Mbarara University of Science and Technology, Mbarara, Uganda
| | - Iris Asllani
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, New York, USA
| | - Udunna Anazodo
- Department of Medical Biophysics, Western University, London, Ontario, Canada
- The Research Institute of London Health Sciences Centre and St. Joseph's Health Care, London, Ontario, Canada
| | - Ntobeko A B Ntusi
- Department of Medicine, University of Cape Town and Groote Schuur Hospital, Cape Town, South Africa
- South African Medical Research Council Extramural Unit on Intersection of Noncommunicable Diseases and Infectious Diseases, Cape Town, South Africa
| | - Regina Mammen
- Department of Cardiology, The Essex Cardiothoracic Centre, Basildon, UK
| | - Thoralf Niendorf
- Berlin Ultrahigh Field Facility (BUFF), Max-Delbrück Centre for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Sola Adeleke
- School of Cancer & Pharmaceutical Sciences, King's College London, London, UK
- High Dimensional Neuro-oncology, University College London Queen Square Institute of Neurology, Faculty of Brain Sciences, University College London, London, UK
| |
Collapse
|
4
|
Wright SM. An Accessible and Flexible Spectrometer for Teaching and Research in MRI Based on the Analog Discovery. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2024; 2024:1-4. [PMID: 40039315 DOI: 10.1109/embc53108.2024.10781621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/06/2025]
Abstract
Despite the proliferation of commercial MRI scanners across much of the world, there are many approaches to constructing low-cost MRI systems being reported. These respond to many needs, from teaching to research accessibility to accessible clinical health care. Most require a fairly high level of expertise to develop the actual system or use relatively expensive hardware. Here we present a minimal, but very capable MRI scanner constructed from the widely used Digilent Analog Discovery II or III devices. Very few external components are required, all available at low-cost from Amazon or other vendors. All programming is done in python, no expertise in FPGA programming or other low-level languages is required. A variety of applications are demonstrated, illustrating the capability of this minimalist system. By using widely available and relatively inexpensive components, the proposed system should make research and education in MRI available to essentially anyone anywhere in the world.
Collapse
|
5
|
Algarín JM, Guallart-Naval T, Borreguero J, Galve F, Alonso J. MaRGE: A graphical environment for MaRCoS. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2024; 361:107662. [PMID: 38574458 DOI: 10.1016/j.jmr.2024.107662] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 03/14/2024] [Accepted: 03/18/2024] [Indexed: 04/06/2024]
Abstract
The open-source console MaRCoS, which stands for "Magnetic Resonance Control System", combines hardware, firmware and software elements for integral control of Magnetic Resonance Imaging (MRI) scanners. Previous developments have focused on making the system robust and reliable, rather than on users, who have been somewhat overlooked. This work describes a Graphical User Interface (GUI) designed for intuitive control of MaRCoS, as well as compatibility with clinical environments. The GUI is based on an arrangement of tabs and a renewed Application Program Interface (API). Compared to the previous versions, the MaRGE package ("MaRCoS Graphical Environment") includes new functionalities such as the possibility to export images to standard DICOM formats, create and manage clinical protocols, or display and process image reconstructions, among other features conceived to simplify the operation of MRI scanners. All prototypes in our facilities are commanded by MaRCoS and operated with the new GUI. Here we report on its performance on an experimental 0.2 T scanner designed for hard-tissue, as well as a 72 mT portable scanner presently installed in the radiology department of a large hospital. The possibility to customize, adapt and streamline processes has substantially improved our workflows and overall experience.
Collapse
Affiliation(s)
- José M Algarín
- MRILab, Institute for Molecular Imaging and Instrumentation (i3M), Spanish National Research Council (CSIC) and Universitat Politècnica de València (UPV), 46022 Valencia, Spain
| | - Teresa Guallart-Naval
- MRILab, Institute for Molecular Imaging and Instrumentation (i3M), Spanish National Research Council (CSIC) and Universitat Politècnica de València (UPV), 46022 Valencia, Spain
| | | | - Fernando Galve
- MRILab, Institute for Molecular Imaging and Instrumentation (i3M), Spanish National Research Council (CSIC) and Universitat Politècnica de València (UPV), 46022 Valencia, Spain
| | - Joseba Alonso
- MRILab, Institute for Molecular Imaging and Instrumentation (i3M), Spanish National Research Council (CSIC) and Universitat Politècnica de València (UPV), 46022 Valencia, Spain.
| |
Collapse
|
6
|
Negnevitsky V, Vives-Gilabert Y, Algarín JM, Craven-Brightman L, Pellicer-Guridi R, O'Reilly T, Stockmann JP, Webb A, Alonso J, Menküc B. MaRCoS, an open-source electronic control system for low-field MRI. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2023; 350:107424. [PMID: 37001194 DOI: 10.1016/j.jmr.2023.107424] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2022] [Revised: 02/20/2023] [Accepted: 03/13/2023] [Indexed: 05/10/2023]
Abstract
Every magnetic resonance imaging (MRI) device requires an electronic control system that handles pulse sequences and signal detection and processing. Here we provide details on the architecture and performance of MaRCoS, a MAgnetic Resonance COntrol System developed by an open international community of low-field MRI researchers. MaRCoS is inexpensive and can handle cycle-accurate sequences without hard length limitations, rapid bursts of events, and arbitrary waveforms. It has also been readily adapted to meet the requirements of the various academic and private institutions participating in its development. We describe the MaRCoS hardware, firmware and software that enable all of the above, including a Python-based graphical user interface for pulse sequence implementation, data processing and image reconstruction.
Collapse
Affiliation(s)
| | - Yolanda Vives-Gilabert
- Intelligent Data Analysis Laboratory, Department of Electronic Engineering, Universitat de València, Valencia, Spain
| | - José M Algarín
- MRILab, Institute for Molecular Imaging and Instrumentation (i3M), Spanish National Research Council (CSIC) and Universitat Politècnica de València (UPV), Valencia, Spain
| | - Lincoln Craven-Brightman
- Massachusetts General Hospital, A. A. Martinos Center for Biomedical Imaging, Charlestown, MA, USA
| | - Rubén Pellicer-Guridi
- Asociación de Investigación MPC, Manuel de Lardizábal 5, Donostia-San Sebastián 20018, Spain
| | - Thomas O'Reilly
- Department of Radiology, Leiden University Medical Center, Albinusdreef 2, Leiden 2333, Netherlands
| | - Jason P Stockmann
- Massachusetts General Hospital, A. A. Martinos Center for Biomedical Imaging, Charlestown, MA, USA
| | - Andrew Webb
- Department of Radiology, Leiden University Medical Center, Albinusdreef 2, Leiden 2333, Netherlands
| | - Joseba Alonso
- MRILab, Institute for Molecular Imaging and Instrumentation (i3M), Spanish National Research Council (CSIC) and Universitat Politècnica de València (UPV), Valencia, Spain
| | - Benjamin Menküc
- University of Applied Sciences and Arts Dortmund, Sonnenstr. 96, Dortmund 44139, Germany.
| |
Collapse
|
7
|
Guallart‐Naval T, O'Reilly T, Algarín JM, Pellicer‐Guridi R, Vives‐Gilabert Y, Craven‐Brightman L, Negnevitsky V, Menküc B, Galve F, Stockmann JP, Webb A, Alonso J. Benchmarking the performance of a low-cost magnetic resonance control system at multiple sites in the open MaRCoS community. NMR IN BIOMEDICINE 2023; 36:e4825. [PMID: 36097704 PMCID: PMC10078257 DOI: 10.1002/nbm.4825] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 08/15/2022] [Accepted: 08/26/2022] [Indexed: 05/15/2023]
Abstract
PURPOSE To describe the current properties and capabilities of an open-source hardware and software package that is being developed by many sites internationally with the aim of providing an inexpensive yet flexible platform for low-cost MRI. METHODS This article describes three different setups from 50 to 360 mT in different settings, all of which used the MaRCoS console for acquiring data, and different types of software interface (custom-built GUI or Pulseq overlay) to acquire it. RESULTS Images are presented both from phantoms and in vivo from healthy volunteers to demonstrate the image quality that can be obtained from the MaRCoS hardware/software interfaced to different low-field magnets. CONCLUSIONS The results presented here show that a number of different sequences commonly used in the clinic can be programmed into an open-source system relatively quickly and easily, and can produce good quality images even at this early stage of development. Both the hardware and software will continue to develop, and it is an aim of this article to encourage other groups to join this international consortium.
Collapse
Affiliation(s)
- Teresa Guallart‐Naval
- MRILab, Institute for Molecular Imaging and Instrumentation (i3M)Spanish National Research Council (CSIC) and Universitat Politècnica de València (UPV)ValenciaSpain
- Tesoro Imaging S.L.ValenciaSpain
| | - Thomas O'Reilly
- Department of RadiologyLeiden University Medical CenterLeidenThe Netherlands
| | - José M. Algarín
- MRILab, Institute for Molecular Imaging and Instrumentation (i3M)Spanish National Research Council (CSIC) and Universitat Politècnica de València (UPV)ValenciaSpain
| | | | - Yolanda Vives‐Gilabert
- Intelligent Data Analysis Laboratory, Department of Electronic EngineeringUniversitat de ValènciaValenciaSpain
| | | | | | - Benjamin Menküc
- University of Applied Sciences and Arts DortmundDortmundGermany
| | - Fernando Galve
- MRILab, Institute for Molecular Imaging and Instrumentation (i3M)Spanish National Research Council (CSIC) and Universitat Politècnica de València (UPV)ValenciaSpain
| | - Jason P. Stockmann
- Massachusetts General Hospital, A. A. Martinos Center for Biomedical ImagingCharlestownMAUSA
| | - Andrew Webb
- Department of RadiologyLeiden University Medical CenterLeidenThe Netherlands
| | - Joseba Alonso
- MRILab, Institute for Molecular Imaging and Instrumentation (i3M)Spanish National Research Council (CSIC) and Universitat Politècnica de València (UPV)ValenciaSpain
| |
Collapse
|
8
|
Sun C, Patel K, Wilcox M, Dimitrov IE, Cheshkov S, McDougall M, Wright SM. A retrofit to enable dynamic B 1 + steering for transmit arrays without multiple amplifiers. Magn Reson Med 2020; 85:3497-3509. [PMID: 33314274 DOI: 10.1002/mrm.28632] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Revised: 10/28/2020] [Accepted: 11/13/2020] [Indexed: 12/13/2022]
Abstract
PURPOSE B 1 + shimming is an important method for mitigating B1 inhomogeneity in high-field MRI. Using independent power amplifiers for each transmit (Tx) element is the preferred method for B1 shimming but comes with a high cost. Conversely, the simplest approach to control a Tx array is by using coaxial cables of varying length in the Tx chain, but this approach is cumbersome and impractical for dynamic shimming. In this article, a system is described that enables dynamic, phase-only, eight-channel B 1 + steering on a 7T MR scanner with only two power amplifiers. METHODS Power dividers were utilized to first split the existing two-channel Tx signal into eight channels. Digitally controlled phase shifters on each channel were designed to provide independent phase shifts with a resolution of 22.5° (from 0°, 22.5° … 337.5°). To validate the system, an eight-channel body dipole array was simulated and constructed for bench and 7T imaging and evaluation. RESULTS The phase conjugate B 1 + steering method was employed at three different spatial positions in simulation, bench measurements, and scanner measurements-all with matching results. At the desired points, regions with homogenous B 1 + were generated, indicating good Tx steering to the selected region. CONCLUSION The described system can be used as a simple retrofit to existing hardware to provide phase control while avoiding the need to manually switch cables and without requiring independent power amplifiers for each channel, thus demonstrating the ability to perform dynamic B 1 + shimming with increased degrees of freedom but without significantly increased hardware cost.
Collapse
Affiliation(s)
- Chenhao Sun
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas, USA
| | - Kevin Patel
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas, USA
| | - Matthew Wilcox
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
| | - Ivan E Dimitrov
- Philips Healthcare, Gainesville, Florida, USA.,Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Sergey Cheshkov
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA.,Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Mary McDougall
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas, USA.,Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
| | - Steven M Wright
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas, USA.,Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
| |
Collapse
|
9
|
Michal CA. Low-cost low-field NMR and MRI: Instrumentation and applications. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 319:106800. [PMID: 33036708 PMCID: PMC7538153 DOI: 10.1016/j.jmr.2020.106800] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 07/25/2020] [Accepted: 07/26/2020] [Indexed: 05/29/2023]
Abstract
While NMR and MRI are often thought of as expensive techniques requiring large institutional investment, opportunities for low-cost, low-field NMR and MRI abound. We discuss a number of approaches to performing magnetic resonance experiments with inexpensive, easy to find or build components, aimed at applications in industry, education, and research. Opportunities that aim to make NMR accessible to a broad community are highlighted. We describe and demonstrate some projects from our laboratory, including a new prototype instrument for measurements at frequencies up to ∼200 kHz and demonstrate its application to the study of the rapidly advancing technique known as inhomogeneous magnetization transfer imaging, a promising method for characterizing myelin in vivo.
Collapse
Affiliation(s)
- Carl A Michal
- Department of Physics and Astronomy, University of British Columbia, 6224 Agricultural Road, Vancouver, BC V6T 1Z1, Canada.
| |
Collapse
|
10
|
Wald LL, McDaniel PC, Witzel T, Stockmann JP, Cooley CZ. Low-cost and portable MRI. J Magn Reson Imaging 2020; 52:686-696. [PMID: 31605435 PMCID: PMC10644353 DOI: 10.1002/jmri.26942] [Citation(s) in RCA: 99] [Impact Index Per Article: 19.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2019] [Accepted: 09/04/2019] [Indexed: 11/16/2023] Open
Abstract
Research in MRI technology has traditionally expanded diagnostic benefit by developing acquisition techniques and instrumentation to enable MRI scanners to "see more." This typically focuses on improving MRI's sensitivity and spatiotemporal resolution, or expanding its range of biological contrasts and targets. In complement to the clear benefits achieved in this direction, extending the reach of MRI by reducing its cost, siting, and operational burdens also directly benefits healthcare by increasing the number of patients with access to MRI examinations and tilting its cost-benefit equation to allow more frequent and varied use. The introduction of low-cost, and/or truly portable scanners, could also enable new point-of-care and monitoring applications not feasible for today's scanners in centralized settings. While cost and accessibility have always been considered, we have seen tremendous advances in the speed and spatial-temporal capabilities of general-purpose MRI scanners and quantum leaps in patient comfort (such as magnet length and bore diameter), but only modest success in the reduction of cost and siting constraints. The introduction of specialty scanners (eg, extremity, brain-only, or breast-only scanners) have not been commercially successful enough to tilt the balance away from the prevailing model: a general-purpose scanner in a centralized healthcare location. Portable MRI scanners equivalent to their counterparts in ultrasound or even computed tomography have not emerged and MR monitoring devices exist only in research laboratories. Nonetheless, recent advances in hardware and computational technology as well as burgeoning markets for MRI in the developing world has created a resurgence of interest in the topic of low-cost and accessible MRI. This review examines the technical forces and trade-offs that might facilitate a large step forward in the push to "jail-break" MRI from its centralized location in healthcare and allow it to reach larger patient populations and achieve new uses. Level of Evidence: 5 Technical Efficacy Stage: 6 J. Magn. Reson. Imaging 2019. J. Magn. Reson. Imaging 2020;52:686-696.
Collapse
Affiliation(s)
- Lawrence L. Wald
- Athinoula A Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
- Division of Health Sciences and Technology, Harvard – Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Patrick C. McDaniel
- Athinoula A Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Thomas Witzel
- Athinoula A Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Jason P. Stockmann
- Athinoula A Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Clarissa Zimmerman Cooley
- Athinoula A Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
11
|
Ogier SE, Wilcox M, Cheshkov S, Dimitrov IE, Malloy CR, McDougall MP, Wright SM. A Frequency Translation System for Multi-Channel, Multi-Nuclear MR Spectroscopy. IEEE Trans Biomed Eng 2020; 68:109-118. [PMID: 32746012 DOI: 10.1109/tbme.2020.2997770] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
OBJECTIVE Most MRI scanners are equipped to receive signals from 1H array coils but few support multi-channel reception for other nuclei. Using receive arrays can provide significant SNR benefits, usually exploited to enable accelerated imaging, but the extension of these arrays to non-1H nuclei has received less attention because of the relative lack of broadband array receivers. Non-1H nuclei often have low sensitivity and stand to benefit greatly from the increase in SNR that arrays can provide. This paper presents a cost-effective approach for adapting standard 1H multi-channel array receivers for use with other nuclei - in this case, 13C. METHODS A frequency translation system has been developed that uses active mixers residing at the magnet bore to convert the received signal from a non-1H array to the 1H frequency for reception by the host system receiver. RESULTS This system has been demonstrated at 4.7T and 7T while preserving SNR and isolation. 1H decoupling, particularly important for 13C detection, can be straightforwardly accommodated. CONCLUSION Frequency translation can convert 1H-only multi-channel receivers for use with other nuclei while maintaining SNR and channel isolation while still enabling 1H decoupling. SIGNIFICANCE This work allows existing multi-channel MRI receivers to be adapted to receive signals from nuclei other than 1H, allowing for the use of receive arrays for in vivo multi-nuclear NMR.
Collapse
|
12
|
Reber J, Marjanovic J, Brunner DO, Port A, Schmid T, Dietrich BE, Moser U, Barmet C, Pruessmann KP. An In-Bore Receiver for Magnetic Resonance Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:997-1007. [PMID: 31484112 DOI: 10.1109/tmi.2019.2939090] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
In magnetic resonance imaging, the use of array detection and the number of detector elements have seen a steady increase over the past two decades. As a result, per-channel analog connection via long coaxial cable, as commonly used, poses an increasing challenge in terms of handling, safety, and coupling among cables. This situation is exacerbated when complementary recording of radiofrequency transmission or NMR-based magnetic field sensing further add to channel counts. A generic way of addressing this trend is the transition to digital signal transmission, enabled by digitization and first-level digital processing close to detector coils and sensors in the magnet bore. The foremost challenge that comes with this approach is to achieve high dynamic range, linearity, and phase stability despite interference by strong static, audiofrequency, and radiofrequency fields. The present work reports implementation of a 16-channel in-bore receiver, performing signal digitization and processing with subsequent optical transmission over fiber. Along with descriptions of the system design and construction, performance evaluation is reported. The resulting device is fully MRI compatible providing practically equal performance and signal quality compared to state-of-the-art RF digitizers operating outside the magnet. Its use is demonstrated by examples of head imaging and magnetic field recording.
Collapse
|
13
|
Eder M, Horneff A, Paul J, Storm A, Wunderlich A, Hell E, Ulrici J, Anders J, Rasche V. A Signal Acquisition Setup for Ultrashort Echo Time Imaging Operating in Parallel on Unmodified Clinical MRI Scanners Achieving an Acquisition Delay of
3
μ
s
. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:218-225. [PMID: 31226070 DOI: 10.1109/tmi.2019.2924057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Ultrashort echo time imaging on clinical systems is still limited by the rather long radio frequency switching times achievable with standard front end concepts. In this contribution, an independent parallel receive-only system is interfaced to an unmodified clinical MRI system, enabling imaging of species with ultrashort relaxation times, such as bone, tendon, teeth, or lung tissue. Synchronization of the system is achieved by an electronically decoupled one-way trigger line, a clock reference signal, and RF pulse tracking, thus ensuring minimal interference with the host system. With the proposed system, an acquisition delay of3 μ s is experimentally demonstrated.
Collapse
|
14
|
Cooley CZ, Stockmann JP, Witzel T, LaPierre C, Mareyam A, Jia F, Zaitsev M, Wenhui Y, Zheng W, Stang P, Scott G, Adalsteinsson E, White JK, Wald LL. Design and implementation of a low-cost, tabletop MRI scanner for education and research prototyping. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 310:106625. [PMID: 31765969 DOI: 10.1016/j.jmr.2019.106625] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 10/19/2019] [Accepted: 10/20/2019] [Indexed: 06/10/2023]
Abstract
While access to a laboratory MRI system is ideal for teaching MR physics as well as many aspects of signal processing, providing multiple MRI scanners can be prohibitively expensive for educational settings. To address this need, we developed a small, low-cost, open-interface tabletop MRI scanner for academic use. We constructed and tested 20 of these scanners for parallel use by teams of 2-3 students in a teaching laboratory. With simplification and down-scaling to a 1 cm FOV, fully-functional scanners were achieved within a budget of $10,000 USD each. The design was successful for teaching MR principles and basic signal processing skills and serves as an accessible testbed for more advanced MR research projects. Customizable GUIs, pulse sequences, and reconstruction code accessible to the students facilitated tailoring the scanner to the needs of laboratory exercise. The scanners have been used by >800 students in 6 different courses and all designs, schematics, sequences, GUIs, and reconstruction code is open-source.
Collapse
Affiliation(s)
- Clarissa Zimmerman Cooley
- A. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA; Harvard Medical School, Boston, MA, USA.
| | - Jason P Stockmann
- A. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA; Harvard Medical School, Boston, MA, USA
| | - Thomas Witzel
- A. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA; Harvard Medical School, Boston, MA, USA
| | - Cris LaPierre
- A. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA
| | - Azma Mareyam
- A. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA
| | - Feng Jia
- Dept. of Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Maxim Zaitsev
- Dept. of Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Yang Wenhui
- Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing, China
| | - Wang Zheng
- Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing, China
| | - Pascal Stang
- Procyon Engineering, San Jose, CA, USA; Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Greig Scott
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Elfar Adalsteinsson
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA; Harvard-MIT Division of Health Sciences Technology, Cambridge, MA, USA
| | - Jacob K White
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Lawrence L Wald
- A. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA; Harvard Medical School, Boston, MA, USA; Harvard-MIT Division of Health Sciences Technology, Cambridge, MA, USA
| |
Collapse
|
15
|
Orzada S, Solbach K, Gratz M, Brunheim S, Fiedler TM, Johst S, Bitz AK, Shooshtary S, Abuelhaija A, Voelker MN, Rietsch SHG, Kraff O, Maderwald S, Flöser M, Oehmigen M, Quick HH, Ladd ME. A 32-channel parallel transmit system add-on for 7T MRI. PLoS One 2019; 14:e0222452. [PMID: 31513637 PMCID: PMC6742215 DOI: 10.1371/journal.pone.0222452] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2019] [Accepted: 08/29/2019] [Indexed: 02/07/2023] Open
Abstract
PURPOSE A 32-channel parallel transmit (pTx) add-on for 7 Tesla whole-body imaging is presented. First results are shown for phantom and in-vivo imaging. METHODS The add-on system consists of a large number of hardware components, including modulators, amplifiers, SAR supervision, peripheral devices, a control computer, and an integrated 32-channel transmit/receive body array. B1+ maps in a phantom as well as B1+ maps and structural images in large volunteers are acquired to demonstrate the functionality of the system. EM simulations are used to ensure safe operation. RESULTS Good agreement between simulation and experiment is shown. Phantom and in-vivo acquisitions show a field of view of up to 50 cm in z-direction. Selective excitation with 100 kHz sampling rate is possible. The add-on system does not affect the quality of the original single-channel system. CONCLUSION The presented 32-channel parallel transmit system shows promising performance for ultra-high field whole-body imaging.
Collapse
Affiliation(s)
- Stephan Orzada
- Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany
- * E-mail:
| | - Klaus Solbach
- RF & Microwave Technology, University of Duisburg-Essen, Duisburg, Germany
| | - Marcel Gratz
- Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany
- High-Field and Hybrid MR Imaging, University Hospital Essen, Essen, Germany
| | - Sascha Brunheim
- Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany
- High-Field and Hybrid MR Imaging, University Hospital Essen, Essen, Germany
| | - Thomas M. Fiedler
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Sören Johst
- Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany
| | - Andreas K. Bitz
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Electromagnetic Theory and Applied Mathematics, Faculty of Electrical Engineering and Information Technology, FH Aachen – University of Applied Sciences, Aachen, Germany
| | - Samaneh Shooshtary
- RF & Microwave Technology, University of Duisburg-Essen, Duisburg, Germany
| | - Ashraf Abuelhaija
- RF & Microwave Technology, University of Duisburg-Essen, Duisburg, Germany
| | - Maximilian N. Voelker
- Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany
- High-Field and Hybrid MR Imaging, University Hospital Essen, Essen, Germany
| | - Stefan H. G. Rietsch
- Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany
- High-Field and Hybrid MR Imaging, University Hospital Essen, Essen, Germany
| | - Oliver Kraff
- Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany
| | - Stefan Maderwald
- Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany
| | - Martina Flöser
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Mark Oehmigen
- High-Field and Hybrid MR Imaging, University Hospital Essen, Essen, Germany
| | - Harald H. Quick
- Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany
- High-Field and Hybrid MR Imaging, University Hospital Essen, Essen, Germany
| | - Mark E. Ladd
- Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Faculty of Physics and Astronomy and Faculty of Medicine, University of Heidelberg, Heidelberg, Germany
| |
Collapse
|
16
|
Huber S, Min C, Staat C, Oh J, Castro CM, Haase A, Weissleder R, Gleich B, Lee H. Multichannel digital heteronuclear magnetic resonance biosensor. Biosens Bioelectron 2019; 126:240-248. [PMID: 30445298 PMCID: PMC6483068 DOI: 10.1016/j.bios.2018.10.052] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2018] [Revised: 10/20/2018] [Accepted: 10/23/2018] [Indexed: 01/05/2023]
Abstract
Low-field, mobile NMR systems are increasingly used across diverse fields, including medical diagnostics, food quality control, and forensics. The throughput and functionality of these systems, however, are limited due to their conventional single-channel detection: one NMR probe exclusively uses an NMR console at any given time. Under this design, multi-channel detection could only be accomplished by either serially accessing individual probes or stacking up multiple copies of NMR electronics; this approach still retains limitations such as long assay times and increased system complexity. Here we present a new scalable architecture, HERMES (hetero-nuclear resonance multichannel electronic system), for versatile, high-throughput NMR analyses. HERMES exploits the concept of software-defined radio by virtualizing NMR electronics in the digital domain. This strategy i) creates multiple NMR consoles without adding extra hardware; ii) acquires signals from multiple NMR channels in parallel; and iii) operates in wide frequency ranges. All of these functions could be realized on-demand in a single compact device. We interfaced HERMES with an array of NMR probes; the combined system simultaneously measured NMR relaxation from multiple samples and resolved spectra of hetero-nuclear spins (1H, 19F, 13C). For potential diagnostic uses, we applied the system to detect dengue fever and molecularly profile cancer cells through multi-channel protein assays. HERMES holds promise as a powerful analytical tool that enables rapid, reconfigurable, and parallel detection.
Collapse
Affiliation(s)
- Stephan Huber
- Center for Systems Biology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA; Munich School of BioEngineering (MSB), Technical University Munich, 85748 Garching, Germany
| | - Changwook Min
- Center for Systems Biology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA; Harvard-MIT Health Sciences and Technology, MIT, Cambridge, MA 02139, USA
| | - Christoph Staat
- Munich School of BioEngineering (MSB), Technical University Munich, 85748 Garching, Germany
| | - Juhyun Oh
- Center for Systems Biology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Cesar M Castro
- Center for Systems Biology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Axel Haase
- Munich School of BioEngineering (MSB), Technical University Munich, 85748 Garching, Germany
| | - Ralph Weissleder
- Center for Systems Biology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA; Department of Systems Biology, Harvard Medical School, Boston, MA 02114, USA
| | - Bernhard Gleich
- Munich School of BioEngineering (MSB), Technical University Munich, 85748 Garching, Germany
| | - Hakho Lee
- Center for Systems Biology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA; Center for NanoMedicine, Institute for Basic Science (IBS), Seoul 03722, Republic of Korea.
| |
Collapse
|
17
|
Hibino Y, Sugahara K, Muro Y, Tanaka H, Sato T, Kondo Y. Simple and low-cost tabletop NMR system for chemical-shift-resolution spectra measurements. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2018; 294:128-132. [PMID: 30036813 DOI: 10.1016/j.jmr.2018.07.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Revised: 06/08/2018] [Accepted: 07/06/2018] [Indexed: 05/03/2023]
Abstract
We have been working on developing a low-cost tabletop NMR system. We reported that a field homogeneity as high as 50 ppm was achieved with a simple NMR magnet by employing two facing ferrite magnets with iron disks in between (Chonlathep et al., 2017). In this paper, we report two improvements added to our previous system: (1) an FPGA based signal processing unit to improve the S/N ratio and (2) a simple shimming mechanism to improve the field homogeneity. We obtained as high as 1 ppm field homogeneity in the best case. The signals from hydrogen nuclear spins in a methyl and carboxy group in acetic acid were resolved in NMR spectra.
Collapse
Affiliation(s)
- Y Hibino
- Graduate School of Science and Engineering Research, Kindai University, 577-8502 Higashi-Osaka, Japan.
| | - K Sugahara
- Graduate School of Science and Engineering Research, Kindai University, 577-8502 Higashi-Osaka, Japan; Department of Electronics and Engineering, Kindai University, 577-8502 Higashi-Osaka, Japan.
| | - Y Muro
- THAMWAY Co., Ltd, 417-0001 Fuji, Japan
| | - H Tanaka
- THAMWAY Co., Ltd, 417-0001 Fuji, Japan
| | - T Sato
- THAMWAY Co., Ltd, 417-0001 Fuji, Japan
| | - Y Kondo
- Graduate School of Science and Engineering Research, Kindai University, 577-8502 Higashi-Osaka, Japan; Department of Physics, Kindai University, 577-8502 Higashi-Osaka, Japan.
| |
Collapse
|
18
|
Dixit N, Stang PP, Pauly JM, Scott GC. Thermo-Acoustic Ultrasound for Detection of RF-Induced Device Lead Heating in MRI. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:536-546. [PMID: 29053449 PMCID: PMC5942199 DOI: 10.1109/tmi.2017.2764425] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Patients who have implanted medical devices with long conductive leads are often restricted from receiving MRI scans due to the danger of RF-induced heating near the lead tips. Phantom studies have shown that this heating varies significantly on a case-by-case basis, indicating that many patients with implanted devices can receive clinically useful MRI scans without harm. However, the difficulty of predicting RF-induced lead tip heating prior to scanning prevents numerous implant recipients from being scanned. Here, we demonstrate that thermo-acoustic ultrasound (TAUS) has the potential to be utilized for a pre-scan procedure assessing the risk of RF-induced lead tip heating in MRI. A system was developed to detect TAUS signals by four different TAUS acquisition methods. We then integrated this system with an MRI scanner and detected a peak in RF power absorption near the tip of a model lead when transmitting from the scanner's body coil. We also developed and experimentally validated simulations to characterize the thermo-acoustic signal generated near lead tips. These results indicate that TAUS is a promising method for assessing RF implant safety, and with further development, a TAUS pre-scan could allow many more patients to have access to MRI scans of significant clinical value.
Collapse
|
19
|
Byron K, Robb F, Stang P, Vasanawala S, Pauly J, Scott G. An RF-gated wireless power transfer system for wireless MRI receive arrays. CONCEPTS IN MAGNETIC RESONANCE. PART B, MAGNETIC RESONANCE ENGINEERING 2017; 47B:e21360. [PMID: 31057343 PMCID: PMC6498852 DOI: 10.1002/cmr.b.21360] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
In MRI systems, cable-free receive arrays would simplify setup while reducing the bulk and weight of coil arrays and improve patient comfort and throughput. Since battery power would limit scan time, wireless power transfer (WPT) is a viable option to continuously supply several watts of power to on-coil electronics. To minimize added noise and decouple the wireless power system from MRI coils, restrictions are placed on the coil geometry of the wireless power system, which are shown to limit its efficiency. Continuous power harvesting can also cause a large increase in the background noise of the image due to diode rectifier up-conversion of noise around the frequency of the transmitted power. However, by RF gating the transmitted power off during the MRI receive time while continuing to supply power from a storage capacitor, WPT is demonstrated to have minimal impact on image quality at received power levels up to 11 W. The integration of WPT with a 1.5T scanner is demonstrated.
Collapse
Affiliation(s)
- Kelly Byron
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | | | | | | | - John Pauly
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Greig Scott
- Department of Electrical Engineering, Stanford University, Stanford, CA USA
| |
Collapse
|
20
|
Hasselwander CJ, Cao Z, Grissom WA. gr-MRI: A software package for magnetic resonance imaging using software defined radios. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2016; 270:47-55. [PMID: 27394165 PMCID: PMC4996692 DOI: 10.1016/j.jmr.2016.06.023] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2016] [Revised: 06/03/2016] [Accepted: 06/30/2016] [Indexed: 05/25/2023]
Abstract
The goal of this work is to develop software that enables the rapid implementation of custom MRI spectrometers using commercially-available software defined radios (SDRs). The developed gr-MRI software package comprises a set of Python scripts, flowgraphs, and signal generation and recording blocks for GNU Radio, an open-source SDR software package that is widely used in communications research. gr-MRI implements basic event sequencing functionality, and tools for system calibrations, multi-radio synchronization, and MR signal processing and image reconstruction. It includes four pulse sequences: a single-pulse sequence to record free induction signals, a gradient-recalled echo imaging sequence, a spin echo imaging sequence, and an inversion recovery spin echo imaging sequence. The sequences were used to perform phantom imaging scans with a 0.5Tesla tabletop MRI scanner and two commercially-available SDRs. One SDR was used for RF excitation and reception, and the other for gradient pulse generation. The total SDR hardware cost was approximately $2000. The frequency of radio desynchronization events and the frequency with which the software recovered from those events was also measured, and the SDR's ability to generate frequency-swept RF waveforms was validated and compared to the scanner's commercial spectrometer. The spin echo images geometrically matched those acquired using the commercial spectrometer, with no unexpected distortions. Desynchronization events were more likely to occur at the very beginning of an imaging scan, but were nearly eliminated if the user invoked the sequence for a short period before beginning data recording. The SDR produced a 500kHz bandwidth frequency-swept pulse with high fidelity, while the commercial spectrometer produced a waveform with large frequency spike errors. In conclusion, the developed gr-MRI software can be used to develop high-fidelity, low-cost custom MRI spectrometers using commercially-available SDRs.
Collapse
Affiliation(s)
- Christopher J Hasselwander
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA; Vanderbilt University Institute of Imaging Science, Nashville, TN, USA.
| | - Zhipeng Cao
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA; Vanderbilt University Institute of Imaging Science, Nashville, TN, USA.
| | - William A Grissom
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA; Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN, USA; Vanderbilt University Institute of Imaging Science, Nashville, TN, USA.
| |
Collapse
|
21
|
Padormo F, Beqiri A, Hajnal JV, Malik SJ. Parallel transmission for ultrahigh-field imaging. NMR IN BIOMEDICINE 2016; 29:1145-61. [PMID: 25989904 PMCID: PMC4995736 DOI: 10.1002/nbm.3313] [Citation(s) in RCA: 143] [Impact Index Per Article: 15.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2014] [Revised: 03/27/2015] [Accepted: 03/29/2015] [Indexed: 05/24/2023]
Abstract
The development of MRI systems operating at or above 7 T has provided researchers with a new window into the human body, yielding improved imaging speed, resolution and signal-to-noise ratio. In order to fully realise the potential of ultrahigh-field MRI, a range of technical hurdles must be overcome. The non-uniformity of the transmit field is one of such issues, as it leads to non-uniform images with spatially varying contrast. Parallel transmission (i.e. the use of multiple independent transmission channels) provides previously unavailable degrees of freedom that allow full spatial and temporal control of the radiofrequency (RF) fields. This review discusses the many ways in which these degrees of freedom can be used, ranging from making more uniform transmit fields to the design of subject-tailored RF pulses for both uniform excitation and spatial selection, and also the control of the specific absorption rate. © 2015 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- Francesco Padormo
- Department of Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King's College London, King's Health Partners, St Thomas' Hospital, London, UK
| | - Arian Beqiri
- Department of Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King's College London, King's Health Partners, St Thomas' Hospital, London, UK
| | - Joseph V Hajnal
- Department of Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King's College London, King's Health Partners, St Thomas' Hospital, London, UK
- Centre for the Developing Brain, Division of Imaging Sciences and Biomedical Engineering, King's College London, King's Health Partners, St Thomas' Hospital, London, UK
| | - Shaihan J Malik
- Department of Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King's College London, King's Health Partners, St Thomas' Hospital, London, UK
| |
Collapse
|
22
|
Layton KJ, Kroboth S, Jia F, Littin S, Yu H, Leupold J, Nielsen JF, Stöcker T, Zaitsev M. Pulseq: A rapid and hardware-independent pulse sequence prototyping framework. Magn Reson Med 2016; 77:1544-1552. [DOI: 10.1002/mrm.26235] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2015] [Revised: 02/12/2016] [Accepted: 03/11/2016] [Indexed: 11/12/2022]
Affiliation(s)
- Kelvin J. Layton
- Department of Radiology; Medical Physics, University Medical Center Freiburg; Freiburg BW Germany
| | - Stefan Kroboth
- Department of Radiology; Medical Physics, University Medical Center Freiburg; Freiburg BW Germany
| | - Feng Jia
- Department of Radiology; Medical Physics, University Medical Center Freiburg; Freiburg BW Germany
| | - Sebastian Littin
- Department of Radiology; Medical Physics, University Medical Center Freiburg; Freiburg BW Germany
| | - Huijun Yu
- Department of Radiology; Medical Physics, University Medical Center Freiburg; Freiburg BW Germany
| | - Jochen Leupold
- Department of Radiology; Medical Physics, University Medical Center Freiburg; Freiburg BW Germany
| | - Jon-Fredrik Nielsen
- Department of Biomedical Engineering; University of Michigan; Ann Arbor Michigan USA
| | - Tony Stöcker
- German Center for Neurodegenerative Diseases; Bonn NRW Germany
| | - Maxim Zaitsev
- Department of Radiology; Medical Physics, University Medical Center Freiburg; Freiburg BW Germany
| |
Collapse
|
23
|
Etezadi-Amoli M, Stang P, Kerr A, Pauly J, Scott G. Controlling radiofrequency-induced currents in guidewires using parallel transmit. Magn Reson Med 2015; 74:1790-802. [PMID: 25521751 PMCID: PMC4470871 DOI: 10.1002/mrm.25543] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2014] [Revised: 10/31/2014] [Accepted: 11/02/2014] [Indexed: 11/09/2022]
Abstract
PURPOSE Elongated conductors, such as pacemaker leads, neurostimulator leads, and conductive guidewires used for interventional procedures can couple to the MRI radiofrequency (RF) transmit field, potentially causing dangerous tissue heating. The purpose of this study was to demonstrate the feasibility of using parallel transmit to control induced RF currents in elongated conductors, thereby reducing the RF heating hazard. METHODS Phantom experiments were performed on a four-channel parallel transmit system at 1.5T. Parallel transmit "null mode" excitations that induce minimal wire current were designed using coupling measurements derived from axial B1 (+) maps. The resulting current reduction performance was evaluated with B1 (+) maps, current sensor measurements, and fluoroptic temperature probe measurements. RESULTS Null mode excitations reduced the maximum coupling mode current by factors ranging from 2 to 80. For the straight wire experiment, a current null imposed at a single wire location was sufficient to reduce tip heating below detectable levels. For longer insertion lengths and a curved geometry, imposing current nulls at two wire locations resulted in more distributed current reduction along the wire length. CONCLUSION Parallel transmit can be used to create excitations that induce minimal RF current in elongated conductors, thereby decreasing the RF heating risk, while still allowing visualization of the surrounding volume.
Collapse
Affiliation(s)
- Maryam Etezadi-Amoli
- Magnetic Resonance Systems Research Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | - Pascal Stang
- Magnetic Resonance Systems Research Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | - Adam Kerr
- Magnetic Resonance Systems Research Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | - John Pauly
- Magnetic Resonance Systems Research Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | - Greig Scott
- Magnetic Resonance Systems Research Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA
| |
Collapse
|
24
|
Active decoupling of RF coils using a transmit array system. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2015; 28:565-76. [DOI: 10.1007/s10334-015-0497-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2015] [Revised: 07/16/2015] [Accepted: 07/17/2015] [Indexed: 10/23/2022]
|
25
|
He Y, Feng J, Zhang Z, Wang C, Wang D, Chen F, Liu M, Liu C. A peripheral component interconnect express-based scalable and highly integrated pulsed spectrometer for solution state dynamic nuclear polarization. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2015; 86:083101. [PMID: 26329168 DOI: 10.1063/1.4927453] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
High sensitivity, high data rates, fast pulses, and accurate synchronization all represent challenges for modern nuclear magnetic resonance spectrometers, which make any expansion or adaptation of these devices to new techniques and experiments difficult. Here, we present a Peripheral Component Interconnect Express (PCIe)-based highly integrated distributed digital architecture pulsed spectrometer that is implemented with electron and nucleus double resonances and is scalable specifically for broad dynamic nuclear polarization (DNP) enhancement applications, including DNP-magnetic resonance spectroscopy/imaging (DNP-MRS/MRI). The distributed modularized architecture can implement more transceiver channels flexibly to meet a variety of MRS/MRI instrumentation needs. The proposed PCIe bus with high data rates can significantly improve data transmission efficiency and communication reliability and allow precise control of pulse sequences. An external high speed double data rate memory chip is used to store acquired data and pulse sequence elements, which greatly accelerates the execution of the pulse sequence, reduces the TR (time of repetition) interval, and improves the accuracy of TR in imaging sequences. Using clock phase-shift technology, we can produce digital pulses accurately with high timing resolution of 1 ns and narrow widths of 4 ns to control the microwave pulses required by pulsed DNP and ensure overall system synchronization. The proposed spectrometer is proved to be both feasible and reliable by observation of a maximum signal enhancement factor of approximately -170 for (1)H, and a high quality water image was successfully obtained by DNP-enhanced spin-echo (1)H MRI at 0.35 T.
Collapse
Affiliation(s)
- Yugui He
- Wuhan National Laboratory for Optoelectronics, School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Jiwen Feng
- State Key Laboratory of Magnet Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan 430071, China
| | - Zhi Zhang
- State Key Laboratory of Magnet Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan 430071, China
| | - Chao Wang
- State Key Laboratory of Magnet Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan 430071, China
| | - Dong Wang
- State Key Laboratory of Magnet Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan 430071, China
| | - Fang Chen
- State Key Laboratory of Magnet Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan 430071, China
| | - Maili Liu
- State Key Laboratory of Magnet Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan 430071, China
| | - Chaoyang Liu
- Wuhan National Laboratory for Optoelectronics, School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China
| |
Collapse
|
26
|
Ellenor CW, Stang PP, Etezadi-Amoli M, Pauly JM, Scott GC. Offline impedance measurements for detection and mitigation of dangerous implant interactions: an RF safety prescreen. Magn Reson Med 2015; 73:1328-39. [PMID: 24623586 PMCID: PMC4162873 DOI: 10.1002/mrm.25202] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2013] [Revised: 02/10/2014] [Accepted: 02/11/2014] [Indexed: 11/18/2022]
Abstract
PURPOSE The concept of a "radiofrequency safety prescreen" is investigated, wherein dangerous interactions between radiofrequency fields used in MRI, and conductive implants in patients are detected through impedance changes in the radiofrequency coil. THEORY The behavior of coupled oscillators is reviewed, and the resulting, observable impedance changes are discussed. METHODS A birdcage coil is loaded with a static head phantom and a wire phantom with a wire close to its resonant length, the shape, position, and orientation of which can be changed. Interactions are probed with a current sensor and network analyzer. RESULTS Impedance spectra show dramatic, unmistakable splitting in cases of strong coupling, and strong correlation is observed between induced current and scattering parameters. CONCLUSIONS The feasibility of a new, low-power prescreening technique has been demonstrated in a simple phantom experiment, which can unambiguously detect resonant interactions between an implanted wire and an imaging coil. A new technique has also been presented which can detect parallel transmit null modes for the wire.
Collapse
Affiliation(s)
| | - Pascal P Stang
- Department of Electrical Engineering, Stanford UniversityStanford, California, USA
- Procyon Engineering, San JoseCalifornia, USA
| | - Maryam Etezadi-Amoli
- Department of Electrical Engineering, Stanford UniversityStanford, California, USA
| | - John M Pauly
- Department of Electrical Engineering, Stanford UniversityStanford, California, USA
| | - Greig C Scott
- Department of Electrical Engineering, Stanford UniversityStanford, California, USA
| |
Collapse
|
27
|
Tang W, Wang W, Liu W, Ma Y, Tang X, Xiao L, Gao JH. A home-built digital optical MRI console using high-speed serial links. Magn Reson Med 2014; 74:578-88. [DOI: 10.1002/mrm.25403] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2014] [Revised: 07/14/2014] [Accepted: 07/21/2014] [Indexed: 11/11/2022]
Affiliation(s)
- Weinan Tang
- Center for MRI Research, Academy for Advanced Interdisciplinary Studies, Peking University; Beijing People's Republic of China
- Beijing City Key Lab for Medical Physics and Engineering, Institute of Heavy Ion Physics, School of Physics, Peking University; Beijing People's Republic of China
- McGovern Institute for Brain Research, Peking University; Beijing People's Republic of China
| | - Weimin Wang
- Center for MRI Research, Academy for Advanced Interdisciplinary Studies, Peking University; Beijing People's Republic of China
- Beijing City Key Lab for Medical Physics and Engineering, Institute of Heavy Ion Physics, School of Physics, Peking University; Beijing People's Republic of China
- Institute of Quantum Electronics, School of Electronic Engineering and Computer Science, Peking University; Beijing People's Republic of China
| | - Wentao Liu
- Center for MRI Research, Academy for Advanced Interdisciplinary Studies, Peking University; Beijing People's Republic of China
- Beijing City Key Lab for Medical Physics and Engineering, Institute of Heavy Ion Physics, School of Physics, Peking University; Beijing People's Republic of China
| | - Yajun Ma
- Center for MRI Research, Academy for Advanced Interdisciplinary Studies, Peking University; Beijing People's Republic of China
- Beijing City Key Lab for Medical Physics and Engineering, Institute of Heavy Ion Physics, School of Physics, Peking University; Beijing People's Republic of China
| | - Xin Tang
- Center for MRI Research, Academy for Advanced Interdisciplinary Studies, Peking University; Beijing People's Republic of China
- Beijing City Key Lab for Medical Physics and Engineering, Institute of Heavy Ion Physics, School of Physics, Peking University; Beijing People's Republic of China
| | - Liang Xiao
- Department of Information Engineering; College of Information Science and Technology, Beijing University of Chemical Technology; Beijing People's Republic of China
| | - Jia-Hong Gao
- Center for MRI Research, Academy for Advanced Interdisciplinary Studies, Peking University; Beijing People's Republic of China
- Beijing City Key Lab for Medical Physics and Engineering, Institute of Heavy Ion Physics, School of Physics, Peking University; Beijing People's Republic of China
- McGovern Institute for Brain Research, Peking University; Beijing People's Republic of China
| |
Collapse
|
28
|
Etezadi-Amoli M, Stang P, Kerr A, Pauly J, Scott G. Interventional device visualization with toroidal transceiver and optically coupled current sensor for radiofrequency safety monitoring. Magn Reson Med 2014; 73:1315-27. [PMID: 24691876 DOI: 10.1002/mrm.25187] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2013] [Revised: 01/25/2014] [Accepted: 01/28/2014] [Indexed: 11/09/2022]
Abstract
PURPOSE The development of catheters and guidewires that are safe from radiofrequency (RF) -induced heating and clearly visible against background tissue is a major challenge in interventional MRI. An interventional imaging approach using a toroidal transmit-receive (transceive) coil is presented. This toroidal transceiver allows controlled, low levels of RF current to flow in the catheter/guidewire for visualization, and can be used with conductive interventional devices that have a localized low-impedance tip contact. METHODS Toroidal transceivers were built, and phantom experiments were performed to quantify transmit power levels required for device visibility and to detect heating hazards. Imaging experiments in a pig cadaver tested the extendibility to higher field strength and nonphantom settings. A photonically powered optically coupled toroidal current sensor for monitoring induced RF currents was built, calibrated, and tested using an independent image-based current estimation method. RESULTS Results indicate that high signal-to-noise ratio visualization is achievable using milliwatts of transmit power-power levels orders of magnitude lower than levels that induce measurable heating in phantom tests. Agreement between image-based current estimates and RF current sensor measurements validates sensor accuracy. CONCLUSION The toroidal transceiver, integrated with power and current sensing, could offer a promising platform for safe and effective interventional device visualization.
Collapse
Affiliation(s)
- Maryam Etezadi-Amoli
- Magnetic Resonance Systems Research Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | | | | | | | | |
Collapse
|
29
|
HASHIMOTO S, KOSE K, HAISHI T. Comparison of Analog and Digital Transceiver Systems for MR Imaging. Magn Reson Med Sci 2014; 13:285-91. [DOI: 10.2463/mrms.2013-0114] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Affiliation(s)
| | - Katsumi KOSE
- Institute of Applied Physics, University of Tsukuba
| | | |
Collapse
|
30
|
Ramirez MS, Lai SY, Bankson JA. A throughput-optimized array system for multiple-mouse MRI. NMR IN BIOMEDICINE 2013; 26:237-47. [PMID: 22887122 PMCID: PMC3543508 DOI: 10.1002/nbm.2841] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2011] [Revised: 05/21/2012] [Accepted: 07/11/2012] [Indexed: 05/15/2023]
Abstract
MRI is a versatile tool for the systematic assessment of anatomical and functional changes in small-animal models of human disease. Its noninvasive nature makes it an ideal candidate for longitudinal evaluations of disease progression, but relatively long scan times limit the number of observations that can be made in a given interval of time, imposing restrictions on experimental design and potentially compromising statistical power. Methods that reduce the overall time required to scan multiple cohorts of animals in distinct experimental groups are therefore highly desirable. Multiple-mouse MRI, in which several animals are simultaneously scanned in a common MRI system, has been successfully used to improve study throughput. However, to best utilize the next generation of small-animal MRI systems that will be equipped with an increased number of receive channels, a paradigm shift from the simultaneous scanning of as many animals as possible to the scanning of a more manageable number, at a faster rate, must be considered. This work explores the tradeoffs between the number of animals to scan at once and the number of array elements dedicated to each animal, to maximize throughput in systems with 16 receive channels. An array system consisting of 15 receive and five transmit coils allows acceleration by a combination of multi-animal and parallel imaging techniques. The array system was designed and fabricated for use on a 7.0-T/30-cm Bruker Biospec MRI system, and tested for high-throughput imaging performance in phantoms and live mice. Results indicate that up to a nine-fold throughput improvement of a single sequence is possible compared with an unaccelerated single-animal acquisition. True data throughput of a contrast-enhanced anatomical study is estimated to be improved by just over six-fold.
Collapse
Affiliation(s)
- Marc S. Ramirez
- Department of Imaging Physics, The University of Texas M. D. Anderson Cancer Center, Houston, Texas
- Department of Biomedical Engineering, The University of Texas, Austin, Texas
| | - Stephen Y. Lai
- Department of Head and Neck Surgery, The University of Texas M. D. Anderson Cancer Center, Houston, Texas
| | - James A. Bankson
- Department of Imaging Physics, The University of Texas M. D. Anderson Cancer Center, Houston, Texas
- Department of Biomedical Engineering, The University of Texas, Austin, Texas
- Please address correspondence to: James A. Bankson, Department of Imaging Physics, Unit 56, The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, TX 77030-4009, Phone: (713) 792–4273, Fax: (713) 745–9236,
| |
Collapse
|
31
|
Tang W, Sun H, Wang W. A digital receiver module with direct data acquisition for magnetic resonance imaging systems. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:104701. [PMID: 23126784 DOI: 10.1063/1.4755089] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
A digital receiver module for magnetic resonance imaging (MRI) with detailed hardware implementations is presented. The module is based on a direct sampling scheme using the latest mixed-signal circuit design techniques. A single field-programmable gate array chip is employed to perform software-based digital down conversion for radio frequency signals. The modular architecture of the receiver allows multiple acquisition channels to be implemented on a highly integrated printed circuit board. To maintain the phase coherence of the receiver and the exciter in the context of direct sampling, an effective phase synchronization method was proposed to achieve a phase deviation as small as 0.09°. The performance of the described receiver module was verified in the experiments for both low- and high-field (0.5 T and 1.5 T) MRI scanners and was compared to a modern commercial MRI receiver system.
Collapse
Affiliation(s)
- Weinan Tang
- Institute of Quantum Electronics, School of Electronic Engineering and Computer Science, Peking University, Beijing, People's Republic of China
| | | | | |
Collapse
|