1
|
Bader KB, Padilla F, Haworth KJ, Ellens N, Dalecki D, Miller DL, Wear KA. Overview of Therapeutic Ultrasound Applications and Safety Considerations: 2024 Update. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2025; 44:381-433. [PMID: 39526313 PMCID: PMC11796337 DOI: 10.1002/jum.16611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2024] [Revised: 10/11/2024] [Accepted: 10/19/2024] [Indexed: 11/16/2024]
Abstract
A 2012 review of therapeutic ultrasound was published to educate researchers and physicians on potential applications and concerns for unintended bioeffects (doi: 10.7863/jum.2012.31.4.623). This review serves as an update to the parent article, highlighting advances in therapeutic ultrasound over the past 12 years. In addition to general mechanisms for bioeffects produced by therapeutic ultrasound, current applications, and the pre-clinical and clinical stages are outlined. An overview is provided for image guidance methods to monitor and assess treatment progress. Finally, other topics relevant for the translation of therapeutic ultrasound are discussed, including computational modeling, tissue-mimicking phantoms, and quality assurance protocols.
Collapse
Affiliation(s)
| | - Frederic Padilla
- Gene Therapy ProgramFocused Ultrasound FoundationCharlottesvilleVirginiaUSA
- Department of RadiologyUniversity of Virginia Health SystemCharlottesvilleVirginiaUSA
| | - Kevin J. Haworth
- Department of PediatricsUniversity of CincinnatiCincinnatiOhioUnited States
- Department of Internal MedicineUniversity of CincinnatiCincinnatiOhioUSA
- Department of Biomedical EngineeringUniversity of CincinnatiCincinnatiOhioUSA
| | | | - Diane Dalecki
- Department of Biomedical EngineeringUniversity of RochesterRochesterNew YorkUSA
| | - Douglas L. Miller
- Department of RadiologyUniversity of Michigan Health SystemAnn ArborMichiganUSA
| | - Keith A. Wear
- Center for Devices and Radiological HealthU.S. Food and Drug AdministrationSilver SpringMarylandUSA
| |
Collapse
|
2
|
Gachouch O, Giammarinaro B, Kangot T, Monini C, Souchon R. A Novel Ultrasound Thermometry Method Based on Thermal Strain and Short and Constant Acoustic Bursts: Preliminary Study in Phantoms. SENSORS (BASEL, SWITZERLAND) 2025; 25:385. [PMID: 39860753 PMCID: PMC11769532 DOI: 10.3390/s25020385] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2024] [Revised: 12/17/2024] [Accepted: 12/21/2024] [Indexed: 01/27/2025]
Abstract
In the field of ultrasound therapy, the estimation of temperature to monitor treatments is becoming essential. We hypothesize that it is possible to measure temperature directly using a constant acoustic power burst. Under the assumption that the acoustic attenuation does not change significantly with temperature, the thermal strain induced by such bursts presents a linear relation with temperature. A mathematical demonstration is given in the introduction. Then, simulations of ultrasound waves in a canine liver model were conducted at different temperatures (from 20 °C to 90 °C). Finally, experimental measurements on phantom samples were performed over the same temperature range. The simulation and experimental results both showed a linear relation between thermal strain and temperature. This relation may suggest the foundation of a new ultrasound-based thermometry method. The potential and limitations of the method are discussed.
Collapse
Affiliation(s)
- Omar Gachouch
- LabTAU, INSERM, F-69003 Lyon, France
- Centre Léon Bérard, F-69003 Lyon, France
- Université Lyon 1, F-69003 Lyon, France
| | - Bruno Giammarinaro
- LabTAU, INSERM, F-69003 Lyon, France
- Centre Léon Bérard, F-69003 Lyon, France
- Université Lyon 1, F-69003 Lyon, France
| | - Teymour Kangot
- LabTAU, INSERM, F-69003 Lyon, France
- Centre Léon Bérard, F-69003 Lyon, France
- Université Lyon 1, F-69003 Lyon, France
| | - Caterina Monini
- LabTAU, INSERM, F-69003 Lyon, France
- Centre Léon Bérard, F-69003 Lyon, France
- Université Lyon 1, F-69003 Lyon, France
| | - Rémi Souchon
- LabTAU, INSERM, F-69003 Lyon, France
- Centre Léon Bérard, F-69003 Lyon, France
- Université Lyon 1, F-69003 Lyon, France
| |
Collapse
|
3
|
Zeng X, Zhang Y, Li Z, Yang J, Gao L, Zhang J. Scatterer spacing based on Gabor atoms matched from harmonic ultrasound echoes to improve assessment of microwave-induced thermal lesions. Med Phys 2024; 51:8943-8961. [PMID: 39298737 DOI: 10.1002/mp.17384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 08/06/2024] [Accepted: 08/10/2024] [Indexed: 09/22/2024] Open
Abstract
BACKGROUND Microwave ablation (MWA) is a minimally invasive alternative for the treatment of unresectable liver tumors. To verify the effectiveness and safety of MWA, it is critical to measure the temperature variation and assess the regions of the microwave-induced thermal lesions. PURPOSE Recent studies have indicated that the locations of optimally matched Gabor atoms (LOMGA) from ultrasound radiofrequency (RF) echo signals allow accurate and stable scatterer spacing estimation. Herein, a harmonic-based LOMGA method is proposed to estimate the scatterer spacing for improving the assessment of microwave-induced thermal lesions. METHODS The mean scatterer spacing (MSS) is estimated via the LOMGA method incorporating the selection of concise atoms from separated second-harmonic RF echo signals with the pulse-inversion algorithm for thermal lesion evaluation. In vitro experiments, 10 fresh porcine liver samples were ablated at different time nodes during the ablation period, and 200 sets of second-harmonic and fundamental RF echo signals were randomly selected from the regions of interest in the coagulated liver samples for MSS estimation. The means and standard deviations of the MSSs, as well as the linear regression for the mean MSSs, were calculated from fundamental and second-harmonic signals for comparison and evaluation, the receiver operating characteristic (ROC) curves for the 200 sets of fundamental-based and harmonic-based MSS estimates from the 10 liver samples at five pairs of adjacent time nodes were calculated, and one-way analysis of variance (ANOVA) tests were performed for the five pairs of adjacent time nodes. The fundamental and harmonic-based p-values in the ANOVA tests and the areas under the ROC curves (AUCs) were calculated to statistically analyze the differences in the MSSs between adjacent time nodes. RESULTS The harmonic-based increments in the intensity variation and coherent components were larger than the fundamental-based increments with the increasing ablation time. The harmonic-based MSSs from the 10 liver samples at five pairs of adjacent time nodes were found to be highly statistically significant (p < 0.01). Thus, the harmonic-based MSSs had greater variations. Compared with the fundamental-based results, for the five preset ST values, the average increment in the harmonic-based mean slopes was 69.22% and the average decrement in the mean standard deviations was 11.67% for the linear-fitting MSS results, and the results were statistically significant (p < 0.05). CONCLUSION Harmonic-based MSSs are more sensitive and robust to variations in coagulated tissues, which is advantageous for the assessment of microwave-induced thermal lesions.
Collapse
Affiliation(s)
- Xiuhua Zeng
- Engineering Research Center of Intelligent System and Advance Materials of Yunnan Province Universities, College of Physics & Electronic Engineering, Qujing Normal University, Qujing, Yunnan, China
| | - Yufeng Zhang
- Department of Electronic Engineering, Information School, Yunnan University, Kunming, Yunnan, China
| | - Zhiyao Li
- The Third Affiliated Hospital of Kunming Medical University, Kunming, Yunnan, China
| | - Jian Yang
- Department of Electronic Engineering, Information School, Yunnan University, Kunming, Yunnan, China
| | - Lian Gao
- Department of Electronic Engineering, Information School, Yunnan University, Kunming, Yunnan, China
| | - Junhua Zhang
- Department of Electronic Engineering, Information School, Yunnan University, Kunming, Yunnan, China
| |
Collapse
|
4
|
Rohfritsch A, Barrere V, Estienne L, Melodelima D. 2D ultrasound thermometry during thermal ablation with high-intensity focused ultrasound. ULTRASONICS 2024; 142:107372. [PMID: 38850600 DOI: 10.1016/j.ultras.2024.107372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 06/02/2024] [Accepted: 06/03/2024] [Indexed: 06/10/2024]
Abstract
The clinical use of high intensity focused ultrasound (HIFU) therapy for noninvasive tissue ablation has recently gained momentum. Guidance is provided by either magnetic resonance imaging (MRI) or conventional B-mode ultrasound imaging, each with its own advantages and disadvantages. The main limitation of ultrasound imaging is its inability to provide temperature measurements over the ranges corresponding to the target temperatures during ablative thermal therapies (between 55 °C and 70 °C). Here, variations in ultrasound backscattered energy (ΔBSE) were used to monitor temperature increases in liver tissue up to an absolute value of 90 °C during and after HIFU treatment. In vitro experimental measurements were performed in 47 bovine liver samples using a toroidal HIFU transducer operating at 2.5 MHz to increase the temperature of tissues. An ultrasound imaging probe working at 7.5 MHz was placed in the center of the HIFU transducer to monitor the backscattered signals. The free-field acoustic power was set to 9 W, 12 W or 16 W in the different experiments. HIFU sonications were performed for 240 s using a duty cycle of 83 % to allow ultrasound imaging and raw radiofrequency data acquisition during exposures. Measurements showed a linear relationship between ΔBSE (in dB) and temperature (r = 0.94, p < 0.001) over a temperature range from 37 °C to 90 °C, with a high reliability of temperature measurements below 75 °C. Monitoring can be performed at the frame rate of ultrasound imaging scanners with an accuracy within an acceptable threshold of 5 °C, given the temperatures targeted during thermal ablations. If the maximum temperature reached is below 70 °C, ΔBSE is also a reliable approach for estimating the temperature during cooling. Histological analysis shown the impact of the treatment on the spatial arrangement of cells that can explain the observed variation of ΔBSE. These results demonstrate the ability of ΔBSE measurements to estimate temperature in ultrasound images within an effective therapeutic range. This method can be implemented clinically and potentially applied to other thermal-based therapies.
Collapse
Affiliation(s)
- Adrien Rohfritsch
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| | - Victor Barrere
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| | - Laura Estienne
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| | - David Melodelima
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France.
| |
Collapse
|
5
|
Delattre V, Cambronero S, Chen Y, Haar GT, Rivens I, Polton G, Lafon C, Melodelima D. In vivo exposure of the bladder using a non-invasive high intensity focused ultrasound toroidal transducer. ULTRASONICS 2024; 138:107239. [PMID: 38211366 DOI: 10.1016/j.ultras.2024.107239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 11/15/2023] [Accepted: 01/01/2024] [Indexed: 01/13/2024]
Abstract
A toroidal high-intensity focused ultrasound (HIFU) transducer was used to expose normal bladder wall tissues non-invasively in vivo in a porcine model in order to investigate the potential to treat bladder tumors. The transducer was divided into 32 concentric rings with equal surface areas, operating at 2.5 MHz. Eight animals were split into two groups of 4. In the first group, post-mortem evaluation was performed immediately after ultrasound exposure. In the second group, animals survived for up to seven days before post-mortem evaluation. The ultrasound imaging guided HIFU device was hand-held during the procedure using optical tracking to ensure correct targeting. One thermal lesion in each animal was created using a 40 s exposure at 80 acoustic Watts (free-field) in the trigone region of the bladder wall. The average (±Standard Deviation) abdominal wall and bladder wall thicknesses were 10.3 ± 1.4 mm and 1.1 ± 0.4 mm respectively. The longest and shortest axes of the HIFU ablations were 7.7 ± 2.9 mm and 6.0 ± 1.8 mm, respectively, resulting in an ablation of the whole thickness of the bladder wall in most cases. Ablation were performed at an average depth (distance from the skin surface to the centre of the HIFU lesion) of 42.5 ± 3.8 mm and extended throughout the thickness of the bladder. There were two cases of injury to tissues immediately adjacent to the bladder wall but without signs of perforation, as confirmed by histological analysis. Non-invasive HIFU ablation using a hand-held toroidal transducer was successfully performed to destroy regions of the bladder wall in vivo.
Collapse
Affiliation(s)
- Victor Delattre
- LabTAU, INSERM, Centre Léon Bérard, Université Claude Bernard Lyon 1, F-69003, Lyon, France.
| | - Sophie Cambronero
- LabTAU, INSERM, Centre Léon Bérard, Université Claude Bernard Lyon 1, F-69003, Lyon, France
| | - Yao Chen
- LabTAU, INSERM, Centre Léon Bérard, Université Claude Bernard Lyon 1, F-69003, Lyon, France
| | - Gail Ter Haar
- Joint Department of Physics, Institute of Cancer Research and Royal Marsden Hospital NHS Trust, Sutton, Surrey, UK
| | - Ian Rivens
- Joint Department of Physics, Institute of Cancer Research and Royal Marsden Hospital NHS Trust, Sutton, Surrey, UK
| | - Gerry Polton
- North Downs Specialist Referrals, Bletchingley, Surrey, UK
| | - Cyril Lafon
- LabTAU, INSERM, Centre Léon Bérard, Université Claude Bernard Lyon 1, F-69003, Lyon, France; Joint Department of Physics, Institute of Cancer Research and Royal Marsden Hospital NHS Trust, Sutton, Surrey, UK
| | - David Melodelima
- LabTAU, INSERM, Centre Léon Bérard, Université Claude Bernard Lyon 1, F-69003, Lyon, France
| |
Collapse
|
6
|
Zhou Z, Gao R, Wu S, Ding Q, Bin G, Tsui PH. Scatterer size estimation for ultrasound tissue characterization: A survey. MEASUREMENT 2024; 225:114046. [DOI: 10.1016/j.measurement.2023.114046] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2025]
|
7
|
Rohfritsch A, Franceschini E, Dupré A, Melodelima D. Quantitative ultrasound techniques for assessing thermal ablation: Measurement of the backscatter coefficient from ex vivo human liver. Med Phys 2023; 50:6908-6919. [PMID: 37769022 DOI: 10.1002/mp.16762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 09/07/2023] [Accepted: 09/12/2023] [Indexed: 09/30/2023] Open
Abstract
BACKGROUND Understanding the changes occurring in biological tissue during thermal ablation is at the heart of many current challenges in both therapy and medical imaging research. PURPOSE The objective of this work is to quantitatively interpret the scattering response of human liver samples, before and after thermal ablation. We report acoustic measurements performed involving n = 21 human liver samples. Thermal ablation is achieved at temperatures between 45 and 80°C and quantification of the irreversible changes in acoustic attenuation and Backscattering Coefficient (BSC) is reported, with a particular attention to the latter. METHODS Both attenuation coefficient and BSCs were measured in the frequency range from 10 to 52 MHz. Scans were performed before heating and after cooling down. Attenuation coefficients were calculated using spectral difference method and BSC estimated using the reference phantom method. RESULTS Strong increases of attenuation coefficients and BSCs with heating temperature were observed. Quantitative ultrasonic parameters obtained with the polydisperse structure factor model (poly-SFM)are compared to histological observations and seen to be close to hepatocyte mean diameter (HMD). CONCLUSIONS The results presented in this study provide a description of the impact of thermal ablation in human liver tissue on acoustic attenuation and the BSC. For the first time, quantitative agreement between the Effective Scatterer Diameter (ESD) estimated from BSC and HMD was shown, highlighting the important role of cellular network in the scattering response of the medium. This core result is an important step toward the determination of the nature of scattering sources in biological tissues.
Collapse
Affiliation(s)
- Adrien Rohfritsch
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, Lyon, France
| | | | - Aurélien Dupré
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, Lyon, France
| | - David Melodelima
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, Lyon, France
| |
Collapse
|
8
|
Li S, Zhou Z, Wu S, Wu W. Ultrasound Homodyned-K Contrast-Weighted Summation Parametric Imaging Based on H-scan for Detecting Microwave Ablation Zones. ULTRASONIC IMAGING 2023; 45:119-135. [PMID: 36995065 DOI: 10.1177/01617346231162928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Abstract
The homodyned-K (HK) distribution is a generalized model of envelope statistics whose parameters α (the clustering parameter) and k (the coherent-to-diffuse signal ratio) can be used to monitor the thermal lesions. In this study, we proposed an ultrasound HK contrast-weighted summation (CWS) parametric imaging algorithm based on the H-scan technique and investigated the optimal window side length (WSL) of the HK parameters estimated by the XU estimator (an estimation method based on the first moment of the intensity and two log-moments, which was used in the proposed algorithm) through phantom simulations. H-scan diversified ultrasonic backscattered signals into low- and high-frequency passbands. After envelope detection and HK parameter estimation for each frequency band, the α and k parametric maps were obtained, respectively. According to the contrast between the target region and background, the (α or k) parametric maps of the dual-frequency band were weighted and summed, and then the CWS images were yielded by pseudo-color imaging. The proposed HK CWS parametric imaging algorithm was used to detect the microwave ablation coagulation zones of porcine liver ex vivo under different powers and treatment durations. The performance of the proposed algorithm was compared with that of the conventional HK parametric imaging and frequency diversity and compounding Nakagami imaging algorithms. For two-dimensional HK parametric imaging, it was found that a WSL equal to 4 pulse lengths of the transducer was sufficient for estimating the α and k parameters in terms of both parameter estimation stability and parametric imaging resolution. The HK CWS parametric imaging provided an improved contrast-to-noise ratio over conventional HK parametric imaging, and the HK αcws parametric imaging achieved the best accuracy and Dice score of coagulation zone detection.
Collapse
Affiliation(s)
- Sinan Li
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, China
| | - Zhuhuang Zhou
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, China
| | - Shuicai Wu
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, China
| | - Weiwei Wu
- College of Biomedical Engineering, Capital Medical University, Beijing, China
| |
Collapse
|
9
|
Implementation of Non-Invasive Quantitative Ultrasound in Clinical Cancer Imaging. Cancers (Basel) 2022; 14:cancers14246217. [PMID: 36551702 PMCID: PMC9776858 DOI: 10.3390/cancers14246217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Accepted: 12/02/2022] [Indexed: 12/23/2022] Open
Abstract
Quantitative ultrasound (QUS) is a non-invasive novel technique that allows treatment response monitoring. Studies have shown that QUS backscatter variables strongly correlate with changes observed microscopically. Increases in cell death result in significant alterations in ultrasound backscatter parameters. In particular, the parameters related to scatterer size and scatterer concentration tend to increase in relation to cell death. The use of QUS in monitoring tumor response has been discussed in several preclinical and clinical studies. Most of the preclinical studies have utilized QUS for evaluating cell death response by differentiating between viable cells and dead cells. In addition, clinical studies have incorporated QUS mostly for tissue characterization, including classifying benign versus malignant breast lesions, as well as responder versus non-responder patients. In this review, we highlight some of the important findings of previous preclinical and clinical studies and expand the applicability and therapeutic benefits of QUS in clinical settings. We summarized some recent clinical research advances in ultrasound-based radiomics analysis for monitoring and predicting treatment response and characterizing benign and malignant breast lesions. We also discuss current challenges, limitations, and future prospects of QUS-radiomics.
Collapse
|
10
|
Li S, Zhou Z, Wu S, Wu W. A Review of Quantitative Ultrasound-Based Approaches to Thermometry and Ablation Zone Identification Over the Past Decade. ULTRASONIC IMAGING 2022; 44:213-228. [PMID: 35993226 DOI: 10.1177/01617346221120069] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Percutaneous thermal therapy is an important clinical treatment method for some solid tumors. It is critical to use effective image visualization techniques to monitor the therapy process in real time because precise control of the therapeutic zone directly affects the prognosis of tumor treatment. Ultrasound is used in thermal therapy monitoring because of its real-time, non-invasive, non-ionizing radiation, and low-cost characteristics. This paper presents a review of nine quantitative ultrasound-based methods for thermal therapy monitoring and their advances over the last decade since 2011. These methods were analyzed and compared with respect to two applications: ultrasonic thermometry and ablation zone identification. The advantages and limitations of these methods were compared and discussed, and future developments were suggested.
Collapse
Affiliation(s)
- Sinan Li
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, China
| | - Zhuhuang Zhou
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, China
| | - Shuicai Wu
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, China
| | - Weiwei Wu
- College of Biomedical Engineering, Capital Medical University, Beijing, China
| |
Collapse
|
11
|
Li X, Jia X, Shen T, Wang M, Yang G, Wang H, Sun Q, Wan M, Zhang S. Ultrasound Entropy Imaging for Detection and Monitoring of Thermal Lesion During Microwave Ablation of Liver. IEEE J Biomed Health Inform 2022; 26:4056-4066. [PMID: 35417359 DOI: 10.1109/jbhi.2022.3167252] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Ultrasonic B-mode imaging offers non-invasive and real-time monitoring of thermal ablation treatment in clinical use, however it faces challenges of moderate lesion-normal contrast and detection accuracy. Quantitative ultrasound imaging techniques have been proposed as promising tools to evaluate the microstructure of ablated tissue. In this study, we introduced Shannon entropy, a non-model based statistical measurement of disorder, to quantitatively detect and monitor microwave-induced ablation in porcine livers. Performance of typical Shannon entropy (TSE), weighted Shannon entropy (WSE), and horizontally normalized Shannon entropy (hNSE) were explored and compared with conventional B-mode imaging. TSE estimated from non-normalized probability distribution histograms was found to have insufficient discernibility of different disorder of data. WSE that improves from TSE by adding signal amplitudes as weights obtained area under receiver operating characteristic (AUROC) curve of 0.895, whereas it underestimated the periphery of lesion region. hNSE provided superior ablated area prediction with the correlation coefficient of 0.90 against ground truth, AUROC of 0.868, and remarkable lesion-normal contrast with contrast-to-noise ratio of 5.86 which was significantly higher than other imaging methods. Data distributions shown in horizontally normalized probability distribution histograms indicated that the disorder of backscattered envelope signal from ablated region increased as treatment went on. These findings suggest that hNSE imaging could be a promising technique to assist ultrasound guided percutaneous thermal ablation.
Collapse
|
12
|
Wen H, Zheng W, Li M, Li Q, Liu Q, Zhou J, Liu Z, Chen X. Multiparametric Quantitative US Examination of Liver Fibrosis: A Feature-engineering and Machine-learning Based Analysis. IEEE J Biomed Health Inform 2021; 26:715-726. [PMID: 34329172 DOI: 10.1109/jbhi.2021.3100319] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Quantitative ultrasound (QUS), which is commonly used to extract quantitative features from the ultrasound radiofrequency (RF) data or the RF envelope signals for tissue characterization, is becoming a promising technique for noninvasive assessments of liver fibrosis. However, the number of feature variables examined and finally used in the existing QUS methods is typically small, to some extent limiting the diagnostic performance. Therefore, this paper devises a new multiparametric QUS (MP-QUS) method which enables the extraction of a large number of feature variables from US RF signals and allows for the use of feature-engineering and machinelearning based algorithms for liver fibrosis assessment. In the MP-QUS, eighty-four feature variables were extracted from multiple QUS parametric maps derived from the RF signals and the envelope data. Afterwards, feature reduction and selection were performed in turn to remove the feature redundancy and identify the best combination of features in the reduced feature set. Finally, a variety of machine-learning algorithms were tested for classifying liver fibrosis with the selected features, based on the results of which the optimal classifier was established and used for final classification. The performance of the proposed MPQUS method for staging liver fibrosis was evaluated on an animal model, with histologic examination as the reference standard. The mean accuracy, sensitivity, specificity and area under the receiver-operating-characteristic curve achieved by MP-QUS are respectively 83.38%, 86.04%, 80.82% and 0.891 for recognizing significant liver fibrosis, and 85.50%, 88.92%, 85.24% and 0.924 for diagnosing liver cirrhosis. The proposed MP-QUS method paves a way for its future extension to assess liver fibrosis in human subjects.
Collapse
|
13
|
Barrere V, Melodelima D, Catheline S, Giammarinaro B. Imaging of Thermal Effects during High-Intensity Ultrasound Treatment in Liver by Passive Elastography: A Preliminary Feasibility in Vitro Study. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:1968-1977. [PMID: 32493631 DOI: 10.1016/j.ultrasmedbio.2020.03.019] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Revised: 03/18/2020] [Accepted: 03/21/2020] [Indexed: 06/11/2023]
Abstract
High-intensity focused ultrasound is a non-invasive modality for thermal ablation of tissues through locally increased temperature. Thermal lesions can be monitored by elastography, following the changes in the elastic properties of the tissue as reflected by the shear-wave velocity. Most studies on ultrasound elastography use shear waves created by acoustic radiation force. However, in the human body, the natural noise resulting from cardiac activity or arterial pulsatility can be used to characterize elasticity through noise-correlation techniques, in the method known as passive elastography. The objective of this study was to investigate the feasibility of monitoring high-intensity ultrasound treatments of liver tissue using passive elastography. Bovine livers were heated to 80°C using a high-intensity planar transducer and imaged with a high-frame-rate ultrasound imaging device. The dynamics of lesion formation are captured through tissue stiffening and lesion expansion.
Collapse
Affiliation(s)
- Victor Barrere
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, Lyon, France
| | - David Melodelima
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, Lyon, France
| | - Stefan Catheline
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, Lyon, France.
| | - Bruno Giammarinaro
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, Lyon, France
| |
Collapse
|
14
|
Zhang S, Wu S, Shang S, Qin X, Jia X, Li D, Cui Z, Xu T, Niu G, Bouakaz A, Wan M. Detection and Monitoring of Thermal Lesions Induced by Microwave Ablation Using Ultrasound Imaging and Convolutional Neural Networks. IEEE J Biomed Health Inform 2020; 24:965-973. [DOI: 10.1109/jbhi.2019.2939810] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|