Ambekar PA, Wang YN, Khokhlova TD, Thomas GPL, Rosnitskiy PB, Contreras K, Leotta DF, Maxwell AD, Bruce M, Pierson S, Totten S, Kumar YN, Thiel J, Chan K, Liles WC, Dellinger EP, Adedipe A, Monsky WL, Matula TJ. Histotripsy-Induced Bactericidal Activity Correlates to Size of Cavitation Cloud In Vitro. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2024; 71:1868-1878. [PMID: 39383065 PMCID: PMC11875908 DOI: 10.1109/tuffc.2024.3476438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/11/2024]
Abstract
Large abscesses are walled-off collections of pus and bacteria that often do not respond to antibiotic therapy. Standard of care involves percutaneous placement of indwelling catheter(s) for drainage, a long and uncomfortable process with high rehospitalization rates. The long-term goal of this work is to develop therapeutic ultrasound approaches to eradicate bacteria within abscesses as a noninvasive therapeutic alternative. Inertial cavitation induced by short pulses of focused ultrasound (histotripsy) is known to generate lethal mechanical damage in bacteria. Prior studies with Escherichia coli (E. coli) in suspension demonstrated that bactericidal effects increase with increasing peak negative amplitude, treatment time, and duty cycle. The current study investigated correlates of bactericidal activity with histotripsy cavitation cloud size. Histotripsy was applied to E. coli suspensions in 10-mL sample vials at 810 kHz, 1.2 MHz, or 3.25 MHz for 40 min. The cavitation activity in the sample vials was separately observed with high-speed photography. The cavitation cloud area was quantified from those images. A linear relationship was observed between bacterial inactivation and cavitation cloud size ( ), regardless of the acoustic parameters (specifically frequency, pulse duration, and power) used to produce the cloud.Index Terms- Abscess, bacterial inactivation, bactericidal activity, cavitation, high intensity focused ultrasound (HIFU), histotripsy, therapeutic ultrasound.
Collapse
|
2
|
Iqbal MF, Shafique MA, Abdur Raqib M, Fadlalla Ahmad TK, Haseeb A, M. A. Mhjoob A, Raja A. Histotripsy: an innovative approach for minimally invasive tumour and disease treatment. Ann Med Surg (Lond) 2024; 86:2081-2087. [PMID: 38576932 PMCID: PMC10990312 DOI: 10.1097/ms9.0000000000001897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Accepted: 02/26/2024] [Indexed: 04/06/2024] Open
Abstract
Histotripsy is a noninvasive medical technique that uses high-intensity focused ultrasound (HIFU) to treat liver tumours. The two main histotripsy methods are boiling histotripsy and cavitation cloud histotripsy. Boiling histotripsy uses prolonged ultrasound pulses to create small boiling bubbles in the tissue, which leads to the breakdown of the tissue into smaller subcellular fragments. Cavitation cloud histotripsy uses the ultrasonic cavitation effect to disintegrate target tissue into precisely defined liquefied lesions. Both methods show similar treatment effectiveness; however, boiling histotripsy ensures treatment stability by producing a stable boiling bubble with each pulse. The therapeutic effect is ascribed to mechanical damage at the subcellular level rather than thermal damage. This article discusses the mechanisms, treatment parameters, and potential of histotripsy as a minimally invasive procedure that provides precise and controlled subcellular damage.
Collapse
Affiliation(s)
| | | | | | | | - Abdul Haseeb
- Department of Medicine, Jinnah Sindh Medical University
| | | | - Adarsh Raja
- Department of Medicine, Shaheed Mohtarma Benazir Bhutto Medical College, Karachi, Pakistan
| |
Collapse
|
3
|
Ambekar PA, Wang YN, Khokhlova T, Bruce M, Leotta DF, Totten S, Maxwell AD, Chan K, Liles WC, Dellinger EP, Monsky W, Adedipe AA, Matula TJ. Comparative Study of Histotripsy Pulse Parameters Used to Inactivate Escherichia coli in Suspension. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:2451-2458. [PMID: 37718123 PMCID: PMC10591824 DOI: 10.1016/j.ultrasmedbio.2023.08.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 06/07/2023] [Accepted: 08/05/2023] [Indexed: 09/19/2023]
Abstract
OBJECTIVE Bacterial loads can be effectively reduced using cavitation-mediated focused ultrasound, or histotripsy. In this study, gram-negative bacteria (Escherichia coli) in suspension were used as model bacteria to evaluate the effectiveness of two regimens of histotripsy treatments: cavitation histotripsy (CH) and boiling histotripsy (BH). METHODS Ten-milliliter volumes of Escherichia coli were treated at different negative focal pressure amplitudes and over time periods up to 40 min. Cavitation activity was characterized with coaxial passive cavitation detection (PCD) and synchronized plane wave B-mode imaging. RESULTS CH treatments exhibited a threshold behavior that was consistent with PCD metrics of cavitation. Above the threshold, bacterial inactivation followed a monotonically increasing log-linear relationship that indicated an exponential inactivation rate. BH exhibited no threshold, but instead followed a different monotonically increasing inactivation rate. Inactivation rates were larger for BH at or below the CH threshold, and larger for CH substantially above the threshold. CH studies performed at different pulse lengths at the same duty cycle had similar inactivation rates, suggesting that at any given pressure amplitude, the "on time" was the most important variable for inactivating E. coli. The maximum inactivation was produced by CH at the highest pressure amplitudes used, leading to a log reduction >4.2 for a 40 min treatment. CONCLUSION The results of this study suggest that both CH and BH can be used to inactivate E. coli in suspension, with the optimal regimen depending on the attainable peak negative focal pressure at the target.
Collapse
Affiliation(s)
- Pratik A Ambekar
- Applied Physics Laboratory, University of Washington, Seattle, WA, USA
| | - Yak-Nam Wang
- Applied Physics Laboratory, University of Washington, Seattle, WA, USA
| | - Tatiana Khokhlova
- Division of Gastroenterology, Department of Medicine, University of Washington, Seattle, WA, USA
| | - Matthew Bruce
- Applied Physics Laboratory, University of Washington, Seattle, WA, USA
| | - Daniel F Leotta
- Applied Physics Laboratory, University of Washington, Seattle, WA, USA
| | - Stephanie Totten
- Applied Physics Laboratory, University of Washington, Seattle, WA, USA
| | - Adam D Maxwell
- Applied Physics Laboratory, University of Washington, Seattle, WA, USA
| | - Keith Chan
- Vantage Radiology and Diagnostic Services, Renton, WA, USA
| | - W Conrad Liles
- Department of Medicine, University of Washington, Seattle, WA, USA; Sepsis Center of Research Excellence-UW (SCORE-UW), University of Washington, Seattle, WA, USA
| | | | - Wayne Monsky
- Department of Radiology, University of Washington, Seattle, WA, USA
| | - Adeyinka A Adedipe
- Department of Emergency Medicine, University of Washington, Seattle, WA, USA
| | - Thomas J Matula
- Applied Physics Laboratory, University of Washington, Seattle, WA, USA.
| |
Collapse
|
4
|
Morse R, Childers C, Nowak E, Rao J, Vlaisavljevich E. Catheter-Based Medical Device Biofilm Ablation Using Histotripsy: A Parameter Study. ULTRASOUND IN MEDICINE & BIOLOGY 2023:S0301-5629(23)00203-X. [PMID: 37394375 DOI: 10.1016/j.ultrasmedbio.2023.06.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 06/07/2023] [Accepted: 06/13/2023] [Indexed: 07/04/2023]
Abstract
OBJECTIVE Biofilm formation in medical catheters is a major source of hospital-acquired infections which can produce increased morbidity and mortality for patients. Histotripsy is a non-invasive, non-thermal focused ultrasound therapy and recently has been found to be effective at removal of biofilm from medical catheters. Previously established histotripsy methods for biofilm removal, however, would require several hours of use to effectively treat a full-length medical catheter. Here, we investigate the potential to increase the speed and efficiency with which biofilms can be ablated from catheters using histotripsy. METHODS Pseudomonas aeruginosa (PA14) biofilms were cultured in in vitro Tygon catheter mimics and treated with histotripsy using a 1 MHz histotripsy transducer and a variety of histotripsy pulsing rates and scanning methods. The improved parameters identified in these studies were then used to explore the bactericidal effect of histotripsy on planktonic PA14 suspended in a catheter mimic. RESULTS Histotripsy can be used to remove biofilm and kill bacteria at substantially increased speeds compared with previously established methods. Near-complete biofilm removal was achieved at treatment speeds up to 1 cm/s, while a 4.241 log reduction in planktonic bacteria was achieved with 2.4 cm/min treatment. CONCLUSION These results represent a 500-fold increase in biofilm removal speeds and a 6.2-fold increase in bacterial killing speeds compared with previously published methods. These findings indicate that histotripsy shows promise for the treatment of catheter-associated biofilms and planktonic bacteria in a clinically relevant time frame.
Collapse
Affiliation(s)
- Ryan Morse
- Virginia Tech Carilion School of Medicine, Virginia Tech, Roanoke, VA, USA.
| | | | - Elizabeth Nowak
- Internal Medicine, Division of Infectious Disease, Carilion Medical Center, Roanoke, VA, USA
| | - Jayasimha Rao
- Virginia Tech Carilion School of Medicine, Virginia Tech, Roanoke, VA, USA; Internal Medicine, Division of Infectious Disease, Carilion Medical Center, Roanoke, VA, USA
| | - Eli Vlaisavljevich
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Roanoke, VA, USA
| |
Collapse
|
5
|
Zhao Y, Bhavya ML, Patange A, Sun DW, Tiwari BK. Plasma-activated liquids for mitigating biofilms on food and food contact surfaces. Compr Rev Food Sci Food Saf 2023; 22:1654-1685. [PMID: 36861750 DOI: 10.1111/1541-4337.13126] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Revised: 01/26/2023] [Accepted: 01/30/2023] [Indexed: 03/03/2023]
Abstract
Plasma-activated liquids (PALs) are emerging and promising alternatives to traditional decontamination technologies and have evolved as a new technology for applications in food, agriculture, and medicine. Contamination caused by foodborne pathogens and their biofilms has posed challenges and concerns to the food industry in terms of safety and quality. The nature of the food and the food processing environment are major factors that contribute to the growth of various microorganisms, followed by the biofilm characteristics that ensure their survival in severe environmental conditions and against traditional chemical disinfectants. PALs show an efficient impact against microorganisms and their biofilms, with various reactive species (short- and long-lived ones), physiochemical properties, and plasma processing factors playing a crucial role in mitigating biofilms. Moreover, there is potential to improve and optimize disinfection strategies using a combination of PALs with other technologies for the inactivation of biofilms. The overarching aim of this study is to build a better understanding of the parameters that govern the liquid chemistry generated in a liquid exposed to plasma and how these translate into biological effects on biofilms. This review provides a current understanding of PALs-mediated mechanisms of action on biofilms; however, the precise inactivation mechanism is still not clear and is an important part of the research. Implementation of PALs in the food industry could help overcome the disinfection hurdles and can enhance biofilm inactivation efficacy. Future perspectives in this field to expand existing state of the art to seek breakthroughs for scale-up and implementation of PALs technology in the food industry are also discussed.
Collapse
Affiliation(s)
- Yunlu Zhao
- Teagasc Food Research Centre, Dublin, Ireland.,Food Refrigeration and Computerised Food Technology (FRCFT), School of Biosystems and Food Engineering, University College Dublin, National University of Ireland, Dublin, Ireland
| | | | | | - Da-Wen Sun
- Food Refrigeration and Computerised Food Technology (FRCFT), School of Biosystems and Food Engineering, University College Dublin, National University of Ireland, Dublin, Ireland
| | | |
Collapse
|
6
|
Childers C, Edsall C, Mehochko I, Mustafa W, Durmaz YY, Klibanov AL, Rao J, Vlaisavljevich E. Particle-Mediated Histotripsy for the Targeted Treatment of Intraluminal Biofilms in Catheter-Based Medical Devices. BME FRONTIERS 2022; 2022:9826279. [PMID: 37850182 PMCID: PMC10521694 DOI: 10.34133/2022/9826279] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Accepted: 05/25/2022] [Indexed: 10/19/2023] Open
Abstract
Objective. This paper is an initial work towards developing particle-mediated histotripsy (PMH) as a novel method of treating catheter-based medical device (CBMD) intraluminal biofilms. Impact Statement. CBMDs commonly become infected with bacterial biofilms leading to medical device failure, infection, and adverse patient outcomes. Introduction. Histotripsy is a noninvasive focused ultrasound ablation method that was recently proposed as a novel method to remove intraluminal biofilms. Here, we explore the potential of combining histotripsy with acoustically active particles to develop a PMH approach that can noninvasively remove biofilms without the need for high acoustic pressures or real-time image guidance for targeting. Methods. Histotripsy cavitation thresholds in catheters containing either gas-filled microbubbles (MBs) or fluid-filled nanocones (NCs) were determined. The ability of these particles to sustain cavitation over multiple ultrasound pulses was tested after a series of histotripsy exposures. Next, the ability of PMH to generate selective intraluminal cavitation without generating extraluminal cavitation was tested. Finally, the biofilm ablation and bactericidal capabilities of PMH were tested using both MBs and NCs. Results. PMH significantly reduced the histotripsy cavitation threshold, allowing for selective luminal cavitation for both MBs and NCs. Results further showed PMH successfully removed intraluminal biofilms in Tygon catheters. Finally, results from bactericidal experiments showed minimal reduction in bacteria viability. Conclusion. The results of this study demonstrate the potential for PMH to provide a new modality for removing bacterial biofilms from CBMDs and suggest that additional work is warranted to develop histotripsy and PMH for treatment of CBMD intraluminal biofilms.
Collapse
Affiliation(s)
| | - Connor Edsall
- Department of Biomedical Engineering and Mechanics, Virginia Tech, USA
| | - Isabelle Mehochko
- Department of Biomedical Engineering and Mechanics, Virginia Tech, USA
| | - Waleed Mustafa
- Department of Biomedical Engineering, Istanbul Medipol University, Turkey
| | | | - Alexander L. Klibanov
- Division of Cardiovascular Medicine (Department of Medicine) and Robert M. Berne Cardiovascular Research Center at University of Virginia School of Medicine, University of Virginia, USA
| | - Jayasimha Rao
- Department of Medicine, Division of Infectious Diseases, Virginia Tech Carilion School of Medicine, USA
| | - Eli Vlaisavljevich
- Department of Biomedical Engineering and Mechanics, Virginia Tech, USA
- ICTAS Center for Engineered Health, Virginia Polytechnic Institute and State University, USA
| |
Collapse
|
7
|
Direct-Contact Low-Frequency Ultrasound and Pulse Lavage Eradicates Biofilms on Implant Materials In Vitro. EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE 2021; 2021:1562605. [PMID: 34504531 PMCID: PMC8423559 DOI: 10.1155/2021/1562605] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 07/25/2021] [Accepted: 08/12/2021] [Indexed: 02/02/2023]
Abstract
Pulse lavage (PL) debridement and ultrasound are both known to be the treatment of biofilm-related periprosthetic joint infection (PJI). However, the efficacy of these in combination is unknown in eradicating biofilm from the orthopaedic metal implant surface. This study was conducted to understand the efficacy of PL and ultrasound in combination in eradicating bacterial biofilms on titanium alloy in vitro. Biofilms of Staphylococcus aureus strains were grown on titanium alloy coupons for 24 h. Then, the coupons were taken to each treatment group: (i) debrided with PL, (ii) exposed to ultrasound, or (iii) exposed to both. An untreated biofilm was set as a control group. Viable plate count and confocal microscopy using live/dead staining was used to measure the amount of biofilm. Viable plate count showed an approximate two-log reduction in CFU/cm2 in PL alone, from an initial cell count on the mental surface of approximately 109 CFU/cm2. The ultrasound caused an approximate seven-log reduction, and the combination group eradicated viable biofilm bacteria completely. Confocal imaging corroborated the CFU data. Our results indicate that PL and ultrasound both are remarkably in eradicating biofilm, and the combination of PL and ultrasound is more effective than alone in reducing biofilm.
Collapse
|
8
|
Childers C, Edsall C, Gannon J, Whittington AR, Muelenaer AA, Rao J, Vlaisavljevich E. Focused Ultrasound Biofilm Ablation: Investigation of Histotripsy for the Treatment of Catheter-Associated Urinary Tract Infections (CAUTIs). IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2965-2980. [PMID: 33950839 DOI: 10.1109/tuffc.2021.3077704] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Urinary catheters often become contaminated with biofilms, resulting in catheter-associated urinary tract infections (CAUTIs) that adversely affect patient outcomes. Histotripsy is a noninvasive focused ultrasound therapy previously developed for the noninvasive ablation of cancerous tumors and soft tissues. Histotripsy has also previously shown the ability to treat biofilms on glass slides and surgical meshes. Here, we investigate the potential of histotripsy for the treatment of CAUTIs for the first time in vitro. Clinically relevant catheter materials (Tygon, Silicone, and latex catheter mimics) and commonly used clinical catheters were tested to determine the feasibility of producing luminal histotripsy bubble clouds. A Pseudomonas aeruginosa (strain PA14) biofilm model was developed and tested to produce luminal biofilms in an in vitro Tygon catheter mimic. This model was treated with histotripsy to determine the ability to remove a luminal biofilm. Finally, the bactericidal effects of histotripsy were tested by treating PA14 suspended inside the Tygon catheter mimic. Results showed that histotripsy produced precise luminal cavitation within all tested catheter mimics and clinical catheters. Histotripsy treatment of a PA14 biofilm with histotripsy reduced luminal biofilm OD590 signal down to background levels. Further, the treatment of suspended PA14 in Luria-Bertani (LB) showed a 3.45 ± 0.11 log10 reduction in CFU/mL after six histotripsy scans across the catheter mimics. Overall, the results of this study demonstrate the potential of histotripsy to provide a new modality for removing bacterial biofilms from catheter-based medical devices and suggest that additional work is warranted to investigate histotripsy for the treatment of CAUTIs and other biomaterial-associated infections.
Collapse
|
9
|
Matula TJ, Wang YN, Khokhlova T, Leotta DF, Kucewicz J, Brayman AA, Bruce M, Maxwell AD, MacConaghy BE, Thomas G, Chernikov VP, Buravkov SV, Khokhlova VA, Richmond K, Chan K, Monsky W. Treating Porcine Abscesses with Histotripsy: A Pilot Study. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:603-619. [PMID: 33250219 PMCID: PMC7855811 DOI: 10.1016/j.ultrasmedbio.2020.10.011] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 09/18/2020] [Accepted: 10/19/2020] [Indexed: 06/12/2023]
Abstract
Infected abscesses are walled-off collections of pus and bacteria. They are a common sequela of complications in the setting of surgery, trauma, systemic infections and other disease states. Current treatment is typically limited to antibiotics with long-term catheter drainage, or surgical washout when inaccessible to percutaneous drainage or unresponsive to initial care efforts. Antibiotic resistance is also a growing concern. Although bacteria can develop drug resistance, they remain susceptible to thermal and mechanical damage. In particular, short pulses of focused ultrasound (i.e., histotripsy) generate mechanical damage through localized cavitation, representing a potential new paradigm for treating abscesses non-invasively, without the need for long-term catheterization and antibiotics. In this pilot study, boiling and cavitation histotripsy treatments were applied to subcutaneous and intramuscular abscesses developed in a novel porcine model. Ultrasound imaging was used to evaluate abscess maturity for treatment monitoring and assessment of post-treatment outcomes. Disinfection was quantified by counting bacteria colonies from samples aspirated before and after treatment. Histopathological evaluation of the abscesses was performed to identify changes resulting from histotripsy treatment and potential collateral damage. Cavitation histotripsy was more successful in reducing the bacterial load while having a smaller treatment volume compared with boiling histotripsy. The results of this pilot study suggest focused ultrasound may lead to a technology for in situ treatment of acoustically accessible abscesses.
Collapse
Affiliation(s)
- Thomas J Matula
- Applied Physics Laboratory, University of Washington, Seattle, Washington, USA.
| | - Yak-Nam Wang
- Applied Physics Laboratory, University of Washington, Seattle, Washington, USA
| | - Tatiana Khokhlova
- Department of Gastroenterology, University of Washington, Seattle, Washington, USA
| | - Daniel F Leotta
- Applied Physics Laboratory, University of Washington, Seattle, Washington, USA
| | - John Kucewicz
- Applied Physics Laboratory, University of Washington, Seattle, Washington, USA
| | - Andrew A Brayman
- Applied Physics Laboratory, University of Washington, Seattle, Washington, USA
| | - Matthew Bruce
- Applied Physics Laboratory, University of Washington, Seattle, Washington, USA
| | - Adam D Maxwell
- Department of Urology, University of Washington, Seattle, Washington, USA
| | - Brian E MacConaghy
- Applied Physics Laboratory, University of Washington, Seattle, Washington, USA
| | - Gilles Thomas
- Applied Physics Laboratory, University of Washington, Seattle, Washington, USA
| | - Valery P Chernikov
- Research Institute of Human Morphology, Laboratory of Cell Pathology, Moscow, Russia
| | - Sergey V Buravkov
- Faculty of Fundamental Medicine, M. V. Lomonosov Moscow State University, Moscow, Russia
| | - Vera A Khokhlova
- Applied Physics Laboratory, University of Washington, Seattle, Washington, USA; Department of Acoustics, Physics Faculty, M. V. Lomonosov Moscow State University, Moscow, Russia
| | | | - Keith Chan
- Department of Radiology, University of Washington, Seattle, Washington, USA
| | - Wayne Monsky
- Department of Radiology, University of Washington, Seattle, Washington, USA
| |
Collapse
|
10
|
Xu Z, Hall TL, Vlaisavljevich E, Lee FT. Histotripsy: the first noninvasive, non-ionizing, non-thermal ablation technique based on ultrasound. Int J Hyperthermia 2021; 38:561-575. [PMID: 33827375 PMCID: PMC9404673 DOI: 10.1080/02656736.2021.1905189] [Citation(s) in RCA: 160] [Impact Index Per Article: 40.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 02/23/2021] [Accepted: 03/12/2021] [Indexed: 01/09/2023] Open
Abstract
Histotripsy is the first noninvasive, non-ionizing, and non-thermal ablation technology guided by real-time imaging. Using focused ultrasound delivered from outside the body, histotripsy mechanically destroys tissue through cavitation, rendering the target into acellular debris. The material in the histotripsy ablation zone is absorbed by the body within 1-2 months, leaving a minimal remnant scar. Histotripsy has also been shown to stimulate an immune response and induce abscopal effects in animal models, which may have positive implications for future cancer treatment. Histotripsy has been investigated for a wide range of applications in preclinical studies, including the treatment of cancer, neurological diseases, and cardiovascular diseases. Three human clinical trials have been undertaken using histotripsy for the treatment of benign prostatic hyperplasia, liver cancer, and calcified valve stenosis. This review provides a comprehensive overview of histotripsy covering the origin, mechanism, bioeffects, parameters, instruments, and the latest results on preclinical and human studies.
Collapse
Affiliation(s)
- Zhen Xu
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Timothy L. Hall
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Eli Vlaisavljevich
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA
| | - Fred T. Lee
- Departments of Radiology, Biomedical Engineering, and Urology, University of Wisconsin, Madison, WI, USA
| |
Collapse
|
11
|
Bigelow TA, Thomas CL, Wu H. Scan Parameter Optimization for Histotripsy Treatment of S. Aureus Biofilms on Surgical Mesh. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:341-349. [PMID: 31634828 PMCID: PMC7039400 DOI: 10.1109/tuffc.2019.2948305] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
There is a critical need to develop new noninvasive therapies to treat bacteria biofilms. Previous studies have demonstrated the effectiveness of cavitation-based ultrasound histotripsy to destroy these biofilms. In this study, the dependence of biofilm destruction on multiple scan parameters was assessed by conducting exposures at different scan speeds (0.3-1.4 beamwidths/s), step sizes (0.25-0.5 beamwidths), and the number of passes of the focus across the mesh (2-6). For each of the exposure conditions, the number of colony-forming units (CFUs) remaining on the mesh was quantified. A regression analysis was then conducted, revealing that the scan speed was the most critical parameter for biofilm destruction. Reducing the number of passes and the scan speed should allow for more efficient biofilm destruction in the future, reducing the treatment time.
Collapse
|
12
|
Lattwein KR, Shekhar H, Kouijzer JJP, van Wamel WJB, Holland CK, Kooiman K. Sonobactericide: An Emerging Treatment Strategy for Bacterial Infections. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:193-215. [PMID: 31699550 PMCID: PMC9278652 DOI: 10.1016/j.ultrasmedbio.2019.09.011] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2019] [Revised: 09/03/2019] [Accepted: 09/16/2019] [Indexed: 05/04/2023]
Abstract
Ultrasound has been developed as both a diagnostic tool and a potent promoter of beneficial bio-effects for the treatment of chronic bacterial infections. Bacterial infections, especially those involving biofilm on implants, indwelling catheters and heart valves, affect millions of people each year, and many deaths occur as a consequence. Exposure of microbubbles or droplets to ultrasound can directly affect bacteria and enhance the efficacy of antibiotics or other therapeutics, which we have termed sonobactericide. This review summarizes investigations that have provided evidence for ultrasound-activated microbubble or droplet treatment of bacteria and biofilm. In particular, we review the types of bacteria and therapeutics used for treatment and the in vitro and pre-clinical experimental setups employed in sonobactericide research. Mechanisms for ultrasound enhancement of sonobactericide, with a special emphasis on acoustic cavitation and radiation force, are reviewed, and the potential for clinical translation is discussed.
Collapse
Affiliation(s)
- Kirby R Lattwein
- Department of Biomedical Engineering, Thoraxcenter, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands.
| | - Himanshu Shekhar
- Division of Cardiovascular Health and Disease, Department of Internal Medicine, University of Cincinnati, Cincinnati, Ohio, USA
| | - Joop J P Kouijzer
- Department of Biomedical Engineering, Thoraxcenter, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Willem J B van Wamel
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Christy K Holland
- Division of Cardiovascular Health and Disease, Department of Internal Medicine, University of Cincinnati, Cincinnati, Ohio, USA
| | - Klazina Kooiman
- Department of Biomedical Engineering, Thoraxcenter, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| |
Collapse
|
13
|
Xie S, Cao H, Li J, Prasad Adhikari V, Yang M, Dong Y, Li D, Du Y. Bactericidal effects of high intensity focused ultrasound on Bacillus Calmette-Guerin in vivo and in vitro. Int J Hyperthermia 2020; 36:886-896. [PMID: 31464154 DOI: 10.1080/02656736.2019.1649474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
Abstract
Purpose: The objective of this study was to investigate the bactericidal effects of high intensity focused ultrasound (HIFU) on Bacillus Calmette-Guerin (BCG, a substitute for Mycobacterium tuberculosis) in vitro and in vivo, and to explore the underlying mechanisms. Materials and methods: HIFU, at a fixed frequency of 1 MHz, was applied to both BCG culture suspensions and subcutaneous BCG abscesses in rats. Results: HIFU irradiation significantly reduced the bacterial survival rate and caused temperature elevations both in vitro and in vivo. Furthermore, BCG suspensions irradiated for 15 s at 3185 and 6369 W/cm2 had increased cell wall damage, which resulted in morphological changes compared to the untreated control group. Additionally, we observed histological changes in the rat subcutaneous abscesses after HIFU ablation at 6369 W/cm2. H&E staining of infected lesions showed coagulative necrosis with central nucleus dissolution and increased infiltration of inflammatory cells, as well as nuclear pyknosis and nuclear fragmentation in the periphery. The volumes of the subcutaneous abscesses in the HIFU-treated group were significantly lower than those in the sham-treated group. Conclusion: HIFU has the therapeutic potential to treat BCG-infected tissues in rats. We theorize that a combination of mechanical, cavitation, and thermal effects most efficiently inactivate BCG bacteria via HIFU. This study is expected to provide a bio-plausible basis for a noninvasive and effective treatment for tuberculosis.
Collapse
Affiliation(s)
- Shuang Xie
- State Key Laboratory of Ultrasound Engineering in Medicine Co-Founded by Chongqing and the Ministry of Science and Technology, Chongqing Collaborative Innovation Center for Minimally-Invasive and Noninvasive Medicine, College of Biomedical Engineering, Chongqing Medical University , Chongqing , China
| | - Hua Cao
- State Key Laboratory of Ultrasound Engineering in Medicine Co-Founded by Chongqing and the Ministry of Science and Technology, Chongqing Collaborative Innovation Center for Minimally-Invasive and Noninvasive Medicine, College of Biomedical Engineering, Chongqing Medical University , Chongqing , China
| | - Jianhu Li
- State Key Laboratory of Ultrasound Engineering in Medicine Co-Founded by Chongqing and the Ministry of Science and Technology, Chongqing Collaborative Innovation Center for Minimally-Invasive and Noninvasive Medicine, College of Biomedical Engineering, Chongqing Medical University , Chongqing , China
| | - Vishnu Prasad Adhikari
- State Key Laboratory of Ultrasound Engineering in Medicine Co-Founded by Chongqing and the Ministry of Science and Technology, Chongqing Collaborative Innovation Center for Minimally-Invasive and Noninvasive Medicine, College of Biomedical Engineering, Chongqing Medical University , Chongqing , China
| | - Min Yang
- State Key Laboratory of Ultrasound Engineering in Medicine Co-Founded by Chongqing and the Ministry of Science and Technology, Chongqing Collaborative Innovation Center for Minimally-Invasive and Noninvasive Medicine, College of Biomedical Engineering, Chongqing Medical University , Chongqing , China
| | - Yu Dong
- State Key Laboratory of Ultrasound Engineering in Medicine Co-Founded by Chongqing and the Ministry of Science and Technology, Chongqing Collaborative Innovation Center for Minimally-Invasive and Noninvasive Medicine, College of Biomedical Engineering, Chongqing Medical University , Chongqing , China
| | - Dairong Li
- Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Chongqing Medical University , Chongqing , China
| | - Yonghong Du
- State Key Laboratory of Ultrasound Engineering in Medicine Co-Founded by Chongqing and the Ministry of Science and Technology, Chongqing Collaborative Innovation Center for Minimally-Invasive and Noninvasive Medicine, College of Biomedical Engineering, Chongqing Medical University , Chongqing , China
| |
Collapse
|
14
|
Bigelow TA, Thomas CL, Wu H, Itani KMF. Impact of High-Intensity Ultrasound on Strength of Surgical Mesh When Treating Biofilm Infections. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:38-44. [PMID: 30442604 PMCID: PMC6378954 DOI: 10.1109/tuffc.2018.2881358] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
The use of cavitation-based ultrasound histotripsy to treat infections on surgical mesh has shown great potential. However, any impact of the therapy on the mesh must be assessed before the therapy can be applied in the clinic. The goal of this study was to determine if the cavitation-based therapy would reduce the strength of the mesh thus compromising the functionality of the mesh. First, Staphylococcus aureus biofilms were grown on the surgical mesh samples and exposed to high-intensity ultrasound pulses. For each exposure, the effectiveness of the therapy was confirmed by counting the number of colony forming units (CFUs) on the mesh. Most of the exposed meshes had no CFUs with an average reduction of 5.4-log10 relative to the sham exposures. To quantify the impact of the exposure on mesh strength, the force required to tear the mesh and the maximum mesh expansion before damage were quantified for control, sham, and exposed mesh samples. There was no statistical difference between the exposed and sham/control mesh samples in terms of ultimate tensile strength and corresponding mesh expansion. The only statistical difference was with respect to mesh orientation relative to the applied load. The tensile strength increased by 1.36 N while the expansion was reduced by 1.33 mm between different mesh orientations.
Collapse
Affiliation(s)
- Timothy A. Bigelow
- Center for Nondestructive Evaluation, Iowa State University, Ames, IA 50011
()
| | - Clayton L. Thomas
- Center for Nondestructive Evaluation, Iowa State University, Ames, IA 50011
()
| | - Huaiqing Wu
- Department of Statistics, Iowa State University, Ames, IA 50011 ()
| | - Kamal MF. Itani
- VA Boston Healthcare System, Boston University and Harvard Medical School, West Roxbury, MA 02132
()
| |
Collapse
|
15
|
Lundt J, Hall T, Rao A, Fowlkes JB, Cain C, Lee F, Xu Z. Coalescence of residual histotripsy cavitation nuclei using low-gain regions of the therapy beam during electronic focal steering. Phys Med Biol 2018; 63:225010. [PMID: 30418936 DOI: 10.1088/1361-6560/aaeaf3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Following collapse of a histotripsy cloud, residual microbubbles may persist for seconds, distributed throughout the focus. Their presence can attenuate and scatter subsequent pulses, hindering treatment speed and homogeneity. Previous studies have demonstrated use of separate low-amplitude (~1 MPa) pulses interleaved with histotripsy pulses to drive bubble coalescence (BC), significantly improving treatment speed without sacrificing homogeneity. We propose that by using electronic focal steering (EFS) to direct the therapy focus throughout specially-designed EFS sequences, it is possible to use low-gain regions of the therapy beam to accomplish BC during EFS without any additional acoustic sequence. First, to establish proof of principle for an isolated focus, a 50-foci EFS sequence was constructed with the first position isolated near the geometric focus and remaining positions distributed post-focally. EFS sequences were evaluated in tissue-mimicking phantoms with gas concentrations of 20% and 100% with respect to saturation. Results using an isolated focus demonstrated that at 20% gas concentration, 49 EFS pulses were sufficient to achieve BC in all samples for pulse repetition frequency (PRF) ⩽ 800 Hz and 84.1% ± 3.0% of samples at 5 kHz PRF. For phantoms prepared with 100% gas concentration, BC was achieved by 49 EFS pulses in 39.2% ± 4.7% of samples at 50 Hz PRF and 63.4% ± 15.3% of samples at 5 kHz. To show feasibility of using the EFS-BC method to ablate a large volume quickly, a 1000-foci EFS sequence covering a volume of approximately 27 ml was tested. Results indicate that the BC effect was similarly present. A treatment rate of 27 ± 6 ml min-1 was achieved, which is signficantly faster than standard histotripsy and ultrasound thermal ablation. This study demonstrates that histotripsy with EFS can achieve BC without employing a separate acoustic sequence which has the potential to accelerate large-volume ablation while minimizing energy deposition.
Collapse
Affiliation(s)
- Jonathan Lundt
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, United States of America
| | | | | | | | | | | | | |
Collapse
|
16
|
Bigelow TA, Thomas CL, Wu H, Itani KMF. Histotripsy Treatment of S. Aureus Biofilms on Surgical Mesh Samples Under Varying Scan Parameters. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:1017-1024. [PMID: 29856719 PMCID: PMC6602080 DOI: 10.1109/tuffc.2018.2819363] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Cavitation-based ultrasound histotripsy has shown potential for treating infections on surgical mesh. The goal of this paper was to explore a new scan strategy while assessing the impact of scan speed, scan step size, and the number of cycles in the tone burst on the destruction of S. aureus biofilms grown on surgical mesh samples using ultrasound histotripsy pulses (150 MPa/-17 MPa). For each exposure, the number of colony forming units (CFUs) on the mesh and released onto the surrounding gel was quantified. Most of the exposed mesh samples had no CFUs, and there was a statistically significant reduction in CFUs on the mesh for each of the exposures, with an average reduction of 3.8 log10 relative to the sham. Compared with the sham, there was also a statistically significant reduction in CFUs on the gel with the highest exposures.
Collapse
|