1
|
Dehnen C, Galindo A, Hoff P, Palme O, Maurer L, Raum K, Wiebe E. Quantitative ultrasound imaging reveals distinct fracture-associated differences in tibial intracortical pore morphology and viscoelastic properties in aged individuals with and without diabetes mellitus - an exploratory study. Front Endocrinol (Lausanne) 2024; 15:1474546. [PMID: 39736865 PMCID: PMC11683365 DOI: 10.3389/fendo.2024.1474546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2024] [Accepted: 11/21/2024] [Indexed: 01/01/2025] Open
Abstract
Introduction Diabetes mellitus (DM) is a chronic metabolic disorder that increases fragility fracture risk. Conventional DXA-based areal bone mineral density (aBMD) assessments often underestimate this risk. Cortical Backscatter (CortBS) ultrasound, a radiation-free technique, non-invasively analyzes cortical bone's viscoelastic and microstructural properties. This study aimed to evaluate CortBS's discriminative performance in DM patients compared to DXA and characterize changes in cortical bone microstructure in Type 1 and Type 2 DM (T1DM, T2DM) patients. Methods This in-vivo study included 89 DM patients (T1DM = 39, T2DM = 48) and 76 age- and sex-matched controls. DXA measured aBMD, while CortBS measurements were taken at the anteromedial tibia using a medical ultrasound scanner with custom software. Multivariate analysis of variance assessed the impact of DM type on CortBS and DXA measurement results. Partial least squares discriminant analyses with cross-validation were used to compare the discrimination performance for vertebral, non-vertebral, and any fragility fractures, adjusting for gender, age, and anthropometric parameters (weight, height, BMI). Results Fractures occurred in 8/23 T1DM, 17/18 T2DM, and 16/55 controls. DXA parameters were reduced in fracture patients, with significant diabetes impact. T2DM was associated with altered CortBS parameters, reduced scatterer density, and larger pores. CortBS outperformed DXA in discriminating fracture risk (0.61 ≤ AUC(DXA) ≤ 0.63, 0.68 ≤ AUC(CortBS) ≤ 0.69). Conclusions Both T1DM and T2DM showed altered bone metabolism, with T2DM linked to impaired tissue formation. CortBS provides insights into pathophysiological changes in diabetic bone and provided superior fracture risk assessment in DM patients compared to DXA.
Collapse
Affiliation(s)
- Carolin Dehnen
- Department of Rheumatology and Clinical Immunology, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Berlin, Germany
| | - Angela Galindo
- Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Berlin, Germany
| | - Paula Hoff
- Department of Rheumatology and Clinical Immunology, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Berlin, Germany
- Endokrinologikum Berlin, Medizinisches Versorgungszentrum (MVZ) am Gendarmenmarkt, Berlin, Germany
| | - Oliver Palme
- Endokrinologikum Berlin, Medizinisches Versorgungszentrum (MVZ) am Gendarmenmarkt, Berlin, Germany
| | - Lukas Maurer
- Department of Endocrinology and Metabolic Diseases, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Berlin, Germany
| | - Kay Raum
- Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Berlin, Germany
| | - Edgar Wiebe
- Department of Rheumatology and Clinical Immunology, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Berlin, Germany
| |
Collapse
|
2
|
Wearing SC, Hooper SL, Langton CM, Keiner M, Horstmann T, Crevier-Denoix N, Pourcelot P. The Biomechanics of Musculoskeletal Tissues during Activities of Daily Living: Dynamic Assessment Using Quantitative Transmission-Mode Ultrasound Techniques. Healthcare (Basel) 2024; 12:1254. [PMID: 38998789 PMCID: PMC11241410 DOI: 10.3390/healthcare12131254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2024] [Revised: 06/18/2024] [Accepted: 06/19/2024] [Indexed: 07/14/2024] Open
Abstract
The measurement of musculoskeletal tissue properties and loading patterns during physical activity is important for understanding the adaptation mechanisms of tissues such as bone, tendon, and muscle tissues, particularly with injury and repair. Although the properties and loading of these connective tissues have been quantified using direct measurement techniques, these methods are highly invasive and often prevent or interfere with normal activity patterns. Indirect biomechanical methods, such as estimates based on electromyography, ultrasound, and inverse dynamics, are used more widely but are known to yield different parameter values than direct measurements. Through a series of literature searches of electronic databases, including Pubmed, Embase, Web of Science, and IEEE Explore, this paper reviews current methods used for the in vivo measurement of human musculoskeletal tissue and describes the operating principals, application, and emerging research findings gained from the use of quantitative transmission-mode ultrasound measurement techniques to non-invasively characterize human bone, tendon, and muscle properties at rest and during activities of daily living. In contrast to standard ultrasound imaging approaches, these techniques assess the interaction between ultrasound compression waves and connective tissues to provide quantifiable parameters associated with the structure, instantaneous elastic modulus, and density of tissues. By taking advantage of the physical relationship between the axial velocity of ultrasound compression waves and the instantaneous modulus of the propagation material, these techniques can also be used to estimate the in vivo loading environment of relatively superficial soft connective tissues during sports and activities of daily living. This paper highlights key findings from clinical studies in which quantitative transmission-mode ultrasound has been used to measure the properties and loading of bone, tendon, and muscle tissue during common physical activities in healthy and pathological populations.
Collapse
Affiliation(s)
- Scott C. Wearing
- School of Medicine and Health, Technical University of Munich, 80992 Munich, Bavaria, Germany
| | - Sue L. Hooper
- School of Health, University of the Sunshine Coast, Sippy Downs, QLD 4556, Australia
| | - Christian M. Langton
- Griffith Centre of Rehabilitation Engineering, Griffith University, Southport, QLD 4222, Australia
| | - Michael Keiner
- Department of Exercise and Training Science, German University of Health and Sport, 85737 Ismaning, Bavaria, Germany
| | - Thomas Horstmann
- School of Medicine and Health, Technical University of Munich, 80992 Munich, Bavaria, Germany
| | | | - Philippe Pourcelot
- INRAE, BPLC Unit, Ecole Nationale Vétérinaire d’Alfort, 94700 Maisons-Alfort, France
| |
Collapse
|
3
|
McCandless BA, Raum K, Muller M. The respective and dependent effects of scattering and bone matrix absorption on ultrasound attenuation in cortical bone. Phys Med Biol 2024; 69:115018. [PMID: 38631364 DOI: 10.1088/1361-6560/ad3fff] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Accepted: 04/17/2024] [Indexed: 04/19/2024]
Abstract
Cortical bone is characterized by a dense solid matrix permeated by fluid-filled pores. Ultrasound scattering has potential for the non-invasive evaluation of changes in bone porosity. However, there is an incomplete understanding of the impact of ultrasonic absorption in the solid matrix on ultrasound scattering. In this study, maps were derived from scanning acoustic microscopy images of human femur cross-sections. Finite-difference time domain ultrasound scatter simulations were conducted on these maps. Pore density, diameter distribution of the pores, and nominal absorption values in the solid and fluid matrices were controlled. Ultrasound pulses with a central frequency of 8.2 MHz were propagated, both in through-transmission and backscattering configurations. From these data, the scattering, bone matrix absorption, and attenuation extinction lengths were calculated. The results demonstrated that as absorption in the solid matrix was varied, the scattering, absorption, and attenuation extinction lengths were significantly impacted. It was shown that for lower values of absorption in the solid matrix (less than 2 dB mm-1), attenuation due to scattering dominates, whereas at higher values of absorption (more than 2 dB mm-1), attenuation due to absorption dominates. This will impact how ultrasound attenuation and scattering parameters can be used to extract quantitative information on bone microstructure.
Collapse
Affiliation(s)
- Brett Austin McCandless
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC, United States of America
| | - Kay Raum
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Center for Biomedicine, Center for Regenerative Therapies, D-12203 Berlin, Germany
| | - Marie Muller
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC, United States of America
| |
Collapse
|
4
|
Jia Y, Han S, Li B, Liu C, Ta D. Backscatter measurement of cancellous bone using the ultrasound transit time spectroscopy. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 155:2670-2686. [PMID: 38639562 DOI: 10.1121/10.0025689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Accepted: 03/26/2024] [Indexed: 04/20/2024]
Abstract
Recently, ultrasound transit time spectroscopy (UTTS) was proposed as a promising method for bone quantitative ultrasound measurement. Studies have showed that UTTS could estimate the bone volume fraction and other trabecular bone structure in ultrasonic through-transmission measurements. The goal of this study was to explore the feasibility of UTTS to be adapted in ultrasonic backscatter measurement and further evaluate the performance of backscattered ultrasound transit time spectrum (BS-UTTS) in the measurement of cancellous bone density and structure. First, taking ultrasonic attenuation into account, the concept of BS-UTTS was verified on ultrasonic backscatter signals simulated from a set of scatterers with different positions and intensities. Then, in vitro backscatter measurements were performed on 26 bovine cancellous bone specimens. After a logarithmic compression of the BS-UTTS, a linear fitting of the log-compressed BS-UTTS versus ultrasonic propagated distance was performed and the slope and intercept of the fitted line for BS-UTTS were determined. The associations between BS-UTTS parameters and cancellous bone features were analyzed using simple linear regression. The results showed that the BS-UTTS could make an accurate deconvolution of the backscatter signal and predict the position and intensity of the simulated scatterers eliminating phase interference, even the simulated backscatter signal was with a relatively low signal-to-noise ratio. With varied positions and intensities of the scatterers, the slope of the fitted line for the log-compressed BS-UTTS versus ultrasonic propagated distance (i.e., slope of BS-UTTS for short) yield a high agreement (r2 = 99.84%-99.96%) with ultrasonic attenuation in simulated backscatter signal. Compared with the high-density cancellous bone, the low-density specimen showed more abundant backscatter impulse response in the BS-UTTS. The slope of BS-UTTS yield a significant correlation with bone mineral density (r = 0.87; p < 0.001), BV/TV (r = 0.87; p < 0.001), and cancellous bone microstructures (r up to 0.87; p < 0.05). The intercept of BS-UTTS was also significantly correlated with bone densities (r = -0.87; p < 0.001) and trabecular structures (|r|=0.43-0.80; p < 0.05). However, the slope of the BS-UTTS underestimated attenuation when measurements were performed experimentally. In addition, a significant non-linear relationship was observed between the measured attenuation and the attenuation estimated by the slope of the BS-UTTS. This study demonstrated that the UTTS method could be adapted to ultrasonic backscatter measurement of cancellous bone. The derived slope and intercept of BS-UTTS could be used in the measurement of bone density and microstructure. The backscattered ultrasound transit time spectroscopy might have potential in the diagnosis of osteoporosis in the clinic.
Collapse
Affiliation(s)
- Yan Jia
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
| | - Shuai Han
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
| | - Boyi Li
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
| | - Chengcheng Liu
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
- State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, 201203, China
| | - Dean Ta
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
- State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, 201203, China
- Department of Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, 200438, China
| |
Collapse
|
5
|
Surowiec RK, Does MD, Nyman JS. In Vivo Assessment of Bone Quality Without X-rays. Curr Osteoporos Rep 2024; 22:56-68. [PMID: 38227178 PMCID: PMC11050740 DOI: 10.1007/s11914-023-00856-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 12/22/2023] [Indexed: 01/17/2024]
Abstract
PURPOSE OF REVIEW This review summarizes recent advances in the assessment of bone quality using non-X-ray techniques. RECENT FINDINGS Quantitative ultrasound (QUS) provides multiple measurements of bone characteristics based on the propagation of sound through bone, the attenuation of that sound, and different processing techniques. QUS parameters and model predictions based on backscattered signals can discriminate non-fracture from fracture cases with accuracy comparable to standard bone mineral density (BMD). With advances in magnetic resonance imaging (MRI), bound water and pore water, or a porosity index, can be quantified in several long bones in vivo. Since such imaging-derived measurements correlate with the fracture resistance of bone, they potentially provide new BMD-independent predictors of fracture risk. While numerous measurements of mineral, organic matrix, and bound water by Raman spectroscopy correlate with the strength and toughness of cortical bone, the clinical assessment of person's bone quality using spatially offset Raman spectroscopy (SORS) requires advanced spectral processing techniques that minimize contaminating signals from fat, skin, and blood. Limiting exposure of patients to ionizing radiation, QUS, MRI, and SORS has the potential to improve the assessment of fracture risk and track changes of new therapies that target bone matrix and micro-structure.
Collapse
Affiliation(s)
- Rachel K Surowiec
- Weldon School of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Dr., West Lafayette, IN, 47907, USA
- Department of Radiology and Imaging Sciences, Indiana University School of Medicine, 550 N. University Blvd., Indianapolis, IN, 46202, USA
| | - Mark D Does
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN, 37232, USA
- Institute of Imaging Science, Vanderbilt University Medical Center, 1161 21st Ave. S., Nashville, TN, 37232, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, 1161 21st Ave. S., Nashville, TN, 37232, USA
- Department of Electrical Engineering and Computer Science, Vanderbilt University, 400 24th Ave. S., Nashville, TN, 37212, USA
| | - Jeffry S Nyman
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN, 37232, USA.
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, 1215 21st Ave. S., Suite 4200, Nashville, TN, 37232, USA.
- Vanderbilt Center for Bone Biology, Vanderbilt University Medical Center, 1211 Medical Center Dr., Nashville, TN, 37212, USA.
- Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN, 37212, USA.
| |
Collapse
|
6
|
Requist MR, Mills MK, Carroll KL, Lenz AL. Quantitative Skeletal Imaging and Image-Based Modeling in Pediatric Orthopaedics. Curr Osteoporos Rep 2024; 22:44-55. [PMID: 38243151 DOI: 10.1007/s11914-023-00845-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 12/19/2023] [Indexed: 01/21/2024]
Abstract
PURPOSE OF REVIEW Musculoskeletal imaging serves a critical role in clinical care and orthopaedic research. Image-based modeling is also gaining traction as a useful tool in understanding skeletal morphology and mechanics. However, there are fewer studies on advanced imaging and modeling in pediatric populations. The purpose of this review is to provide an overview of recent literature on skeletal imaging modalities and modeling techniques with a special emphasis on current and future uses in pediatric research and clinical care. RECENT FINDINGS While many principles of imaging and 3D modeling are relevant across the lifespan, there are special considerations for pediatric musculoskeletal imaging and fewer studies of 3D skeletal modeling in pediatric populations. Improved understanding of bone morphology and growth during childhood in healthy and pathologic patients may provide new insight into the pathophysiology of pediatric-onset skeletal diseases and the biomechanics of bone development. Clinical translation of 3D modeling tools developed in orthopaedic research is limited by the requirement for manual image segmentation and the resources needed for segmentation, modeling, and analysis. This paper highlights the current and future uses of common musculoskeletal imaging modalities and 3D modeling techniques in pediatric orthopaedic clinical care and research.
Collapse
Affiliation(s)
- Melissa R Requist
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT, 84108, USA
- Department of Biomedical Engineering, University of Utah, 36 S Wasatch Dr., Salt Lake City, UT, 84112, USA
| | - Megan K Mills
- Department of Radiology and Imaging Sciences, University of Utah, 30 N Mario Capecchi Dr. 2 South, Salt Lake City, UT, 84112, USA
| | - Kristen L Carroll
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT, 84108, USA
- Shriners Hospital for Children, 1275 E Fairfax Rd, Salt Lake City, UT, 84103, USA
| | - Amy L Lenz
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT, 84108, USA.
- Department of Biomedical Engineering, University of Utah, 36 S Wasatch Dr., Salt Lake City, UT, 84112, USA.
| |
Collapse
|
7
|
Karbalaeisadegh Y, Yao S, Zhu Y, Grimal Q, Muller M. Ultrasound Characterization of Cortical Bone Using Shannon Entropy. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:1824-1829. [PMID: 37244812 DOI: 10.1016/j.ultrasmedbio.2023.04.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 04/13/2023] [Accepted: 04/19/2023] [Indexed: 05/29/2023]
Abstract
OBJECTIVE Ultrasound backscattered signals encompass information on the microstructure of heterogeneous media such as cortical bone, in which pores act as scatterers and result in the scattering and multiple scattering of ultrasound waves. The objective of this study was to investigate whether Shannon entropy can be exploited to characterize cortical porosity. METHODS In the study described here, to demonstrate proof of concept, Shannon entropy was used as a quantitative ultrasound parameter to experimentally evaluate microstructural changes in samples with controlled scatterer concentrations made of a highly absorbing polydimethylsiloxane matrix (PDMS). Similar assessment was then performed using numerical simulations on cortical bone structures with varying average pore diameter (Ct.Po.Dm.), density (Ct.Po.Dn.) and porosity (Ct.Po.). RESULTS The results suggest that an increase in pore diameter and porosity lead to an increase in entropy, indicating increased levels of randomness in the signals as a result of increased scattering. The entropy-versus-scatterer volume fraction in PDMS samples indicates an initial increasing trend that slows down as the scatterer concentration increases. High levels of attenuation cause the signal amplitudes and corresponding entropy values to decrease drastically. The same trend is observed when porosity of the bone samples is increased above 15%. CONCLUSION Sensitivity of entropy to microstructural changes in highly scattering and absorbing media can potentially be exploited to diagnose and monitor osteoporosis.
Collapse
Affiliation(s)
- Yasamin Karbalaeisadegh
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC, USA
| | - Shanshan Yao
- Department of Mechanical Engineering, Stony Brook University, Stony Brook, NY, USA
| | - Yong Zhu
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC, USA
| | - Quentin Grimal
- Laboratory of Biomedical Imaging, Sorbonne University, Paris, France
| | - Marie Muller
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC, USA.
| |
Collapse
|
8
|
Webb TD, Fu F, Leung SA, Ghanouni P, Dahl JJ, Does MD, Pauly KB. Improving Transcranial Acoustic Targeting: The Limits of CT-Based Velocity Estimates and the Role of MR. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:2630-2637. [PMID: 35853046 PMCID: PMC9519088 DOI: 10.1109/tuffc.2022.3192224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Transcranial magnetic resonance-guided focused ultrasound (tcMRgFUS) enables the noninvasive treatment of the deep brain. This capacity relies on the ability to focus acoustic energy through the in-tact skull, a feat that requires accurate estimates of the acoustic velocity in individual patient skulls. In current practice, these estimates are generated using a pretreatment computed tomography (CT) scan and then registered to a magnetic resonance (MR) dataset on the day of the treatment. Treatment safety and efficacy can be improved by eliminating the need to register the CT data to the MR images and by improving the accuracy of acoustic velocity measurements. In this study, we examine the capacity of MR to supplement or replace CT as a means of estimating velocity in the skull. We find that MR can predict velocity with less but comparable accuracy to CT. We then use micro-CT imaging to better understand the limitations of Hounsfield unit (HU)-based estimates of velocity, demonstrating that the macrostructure of pores in the skull contributes to the acoustic velocity of the bone. We find evidence that detailed T2 measurements provide information about pore macrostructure similar to the information obtained with micro-CT, offering a potential clinical mechanism for improving patient-specific estimates of acoustic velocity in the human skull.
Collapse
|
9
|
Lye TH, Gachouch O, Renner L, Elezkurtaj S, Cash H, Messroghli D, Raum K, Mamou J. Quantitative Ultrasound Assessment of Early Osteoarthritis in Human Articular Cartilage Using a High-Frequency Linear Array Transducer. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:1429-1440. [PMID: 35537895 PMCID: PMC9246887 DOI: 10.1016/j.ultrasmedbio.2022.03.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Revised: 03/08/2022] [Accepted: 03/10/2022] [Indexed: 06/01/2023]
Abstract
Quantitative ultrasound (QUS) assessment of osteoarthritis (OA) using high-frequency, research-grade single-element ultrasound systems has been reported. The objective of this ex vivo study was to assess the performance of QUS in detecting early OA using a high-frequency linear array transducer. Osteochondral plugs (n = 26) of human articular cartilage were scanned with ExactVu Micro-Ultrasound using an EV29L side-fire transducer. For comparison, the samples were also imaged with SAM200Ex, a custom 40-MHz scanning acoustic microscope with a single-element, focused transducer. Thirteen QUS parameters were derived from the ultrasound data. Magnetic resonance imaging (MRI) data, with T1 and T2 extracted as the quantitative parameters, were also acquired for comparison. Cartilage degeneration was graded from histology and correlated to all quantitative parameters. A maximum Spearman rank correlation coefficient (ρ) of 0.75 was achieved using a combination of ExactVu QUS parameters, while a maximum ρ of 0.62 was achieved using a combination of parameters from SAM200Ex. A maximum ρ of 0.75 was achieved using the T1 and T2 MRI parameters. This study illustrates the potential of a high-frequency linear array transducer to provide a convenient method for early OA screening with results comparable to those of research-grade single-element ultrasound and MRI.
Collapse
Affiliation(s)
- Theresa H Lye
- Frederic L. Lizzi Center for Biomedical Engineering, Riverside Research, New York, New York, USA
| | - Omar Gachouch
- Berlin Institute of Health, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Lisa Renner
- Centrum für Muskuloskeletale Chirurgie (CMSC), Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Sefer Elezkurtaj
- Institut für Pathologie, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Hannes Cash
- Department of Urology, Otto-von-Guericke-University Magdeburg, Germany and PROURO, Berlin, Germany
| | - Daniel Messroghli
- Department of Internal Medicine and Cardiology, Deutsches Herzzentrum Berlin and Charite-Universitätsmedizin Berlin, Berlin, Germany
| | - Kay Raum
- Berlin Institute of Health, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Jonathan Mamou
- Frederic L. Lizzi Center for Biomedical Engineering, Riverside Research, New York, New York, USA.
| |
Collapse
|
10
|
Estimation of Thickness and Speed of Sound for Transverse Cortical Bone Imaging Using Phase Aberration Correction Methods: An In Silico and Ex Vivo Validation Study. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12105283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Delay-and-sum (DAS) beamforming of backscattered echoes is used for conventional ultrasound imaging. Although DAS beamforming is well suited for imaging in soft tissues, refraction, scattering, and absorption, porous mineralized tissues cause phase aberrations of reflected echoes and subsequent image degradation. The recently developed refraction corrected multi-focus technique uses subsequent focusing of waves at variable depths, the tracking of travel times of waves reflected from outer and inner cortical bone interfaces, the estimation of the shift needed to focus from one interface to another to determine cortical thickness (Ct.Th), and the speed of sound propagating in a radial bone direction (Ct.ν11). The method was validated previously in silico and ex vivo on plate shaped samples. The aim of this study was to correct phase aberration caused by bone geometry (i.e., curvature and tilt with respect to the transducer array) and intracortical pores for the multi-focus approach. The phase aberration correction methods are based on time delay estimation via bone geometry differences to flat bone plates and via the autocorrelation and cross correlation of the reflected ultrasound waves from the endosteal bone interface. We evaluate the multi-focus approach by incorporating the phase aberration correction methods by numerical simulation and one experiment on a human tibia bone, and analyze the precision and accuracy of measuring Ct.Th and Ct.ν11. Site-matched reference values of the cortical thickness of the human tibia bone were obtained from high-resolution peripheral computed tomography. The phase aberration correction methods resulted in a more precise (coefficient of variation of 5.7%) and accurate (root mean square error of 6.3%) estimation of Ct.Th, and a more precise (9.8%) and accurate (3.4%) Ct.ν11 estimation, than without any phase aberration correction. The developed multi-focus method including phase aberration corrections provides local estimations of both cortical thickness and sound velocity and is proposed as a biomarker of cortical bone quality with high clinical potential for the prevention of osteoporotic fractures.
Collapse
|
11
|
Karbalaeisadegh Y, Muller M. Ultrasound Scattering in Cortical Bone. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1364:177-196. [PMID: 35508876 PMCID: PMC10823499 DOI: 10.1007/978-3-030-91979-5_9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Recent advances in imaging of bone microstructure have led to a growing recognition of the role of cortical microstructure in osteoporosis. It is now accepted that the assessment of the microstructure of cortical porosity is essential to assess bone mechanical competence and predict fracture risk. Cortical porosity affects the propagation of ultrasound waves because pores act as ultrasound scatterers. Scattering by the porosity is an opportunity that should be leveraged to extract quantitative information about cortical microstructure. Scattering by the pores affects a number of ultrasound parameters that should be quantified, including attenuation, backscatter coefficient, ultrasound diffusivity, and their frequency dependence. Measuring these ultrasound parameters and developing models that describe their dependence upon parameters of cortical microstructure is the key to solve inverse problems that will allow the quantitative assessment of cortical porosity and ultimately will improve the non-invasive ultrasound-based evaluation of bone mechanical competence and fracture risk. In this chapter, we present recent advances in measuring and modeling those parameters in cortical bone.
Collapse
Affiliation(s)
- Yasamin Karbalaeisadegh
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC, USA
| | - Marie Muller
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC, USA.
| |
Collapse
|
12
|
Clinical Devices for Bone Assessment. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1364:35-53. [DOI: 10.1007/978-3-030-91979-5_3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
13
|
Bochud N, Laugier P. Axial Transmission: Techniques, Devices and Clinical Results. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1364:55-94. [DOI: 10.1007/978-3-030-91979-5_4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
14
|
Abstract
PURPOSE OF REVIEW We re-evaluated clinical applications of image-to-FE models to understand if clinical advantages are already evident, which proposals are promising, and which questions are still open. RECENT FINDINGS CT-to-FE is useful in longitudinal treatment evaluation and groups discrimination. In metastatic lesions, CT-to-FE strength alone accurately predicts impending femoral fractures. In osteoporosis, strength from CT-to-FE or DXA-to-FE predicts incident fractures similarly to DXA-aBMD. Coupling loads and strength (possibly in dynamic models) may improve prediction. One promising MRI-to-FE workflow may now be tested on clinical data. Evidence of artificial intelligence usefulness is appearing. CT-to-FE is already clinical in opportunistic CT screening for osteoporosis, and risk of metastasis-related impending fractures. Short-term keys to improve image-to-FE in osteoporosis may be coupling FE with fall risk estimates, pool FE results with other parameters through robust artificial intelligence approaches, and increase reproducibility and cross-validation of models. Modeling bone modifications over time and bone fracture mechanics are still open issues.
Collapse
Affiliation(s)
- Enrico Schileo
- Bioengineering and Computing Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.
| | - Fulvia Taddei
- Bioengineering and Computing Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| |
Collapse
|
15
|
Armbrecht G, Nguyen Minh H, Massmann J, Raum K. Pore-Size Distribution and Frequency-Dependent Attenuation in Human Cortical Tibia Bone Discriminate Fragility Fractures in Postmenopausal Women With Low Bone Mineral Density. JBMR Plus 2021; 5:e10536. [PMID: 34761144 PMCID: PMC8567489 DOI: 10.1002/jbm4.10536] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Accepted: 08/03/2021] [Indexed: 11/21/2022] Open
Abstract
Osteoporosis is a disorder of bone remodeling leading to reduced bone mass, structural deterioration, and increased bone fragility. The established diagnosis is based on the measurement of areal bone mineral density by dual‐energy X‐ray absorptiometry (DXA), which poorly captures individual bone loss and structural decay. Enlarged cortical pores in the tibia have been proposed to indicate structural deterioration and reduced bone strength in the hip. Here, we report for the first time the in vivo assessment of the cortical pore‐size distribution together with frequency‐dependent attenuation at the anteromedial tibia midshaft by means of a novel ultrasonic cortical backscatter (CortBS) technology. We hypothesized that the CortBS parameters are associated with the occurrence of fragility fractures in postmenopausal women (n = 55). The discrimination performance was compared with those of DXA and high‐resolution peripheral computed tomography (HR‐pQCT). The results suggest a superior discrimination performance of CortBS (area under the receiver operating characteristic curve [AUC]: 0.69 ≤ AUC ≤ 0.75) compared with DXA (0.54 ≤ AUC ≤ 0.55) and a similar performance compared with HR‐pQCT (0.66 ≤ AUC ≤ 0.73). CortBS is the first quantitative bone imaging modality that can quantify microstructural tissue deteriorations in cortical bone, which occur during normal aging and the development of osteoporosis. © 2021 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- Gabriele Armbrecht
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Radiology, Center for Muscle and Bone Research Berlin Germany
| | - Huong Nguyen Minh
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Center for Regenerative Therapies Berlin Germany
| | - Jonas Massmann
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Center for Regenerative Therapies Berlin Germany
| | - Kay Raum
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Center for Regenerative Therapies Berlin Germany
| |
Collapse
|
16
|
Minonzio JG, Han C, Cassereau D, Grimal Q. In vivopulse-echo measurement of apparent broadband attenuation and Qfactor in cortical bone: a preliminary study. Phys Med Biol 2021; 66. [PMID: 34192679 DOI: 10.1088/1361-6560/ac1022] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2021] [Accepted: 06/30/2021] [Indexed: 11/11/2022]
Abstract
Quantitative ultrasound (QUS) methods have been introduced to assess cortical bone health at the radius and tibia through the assessment of cortical thickness (Ct.Th), cortical porosity and bulk wave velocities. Ultrasonic attenuation is another QUS parameter which is not currently used. We assessed the feasibility ofin vivomeasurement of ultrasonic attenuation in cortical bone with a broadband transducer with 3.5 MHz center frequency. Echoes from the periosteal and endosteal interfaces were fitted with Gaussian pulses using sparse signal processing. Then, the slope of the broadband ultrasonic attenuation (Ct.nBUA) in cortical bone and quality factorQ11-1were calculated with a parametric approach based on the center-frequency shift. Five human subjects were measured at the one-third distal radius with pulse-echo ultrasound, and reference data was obtained with high-resolution x-ray peripheral computed tomography (Ct.Th and cortical volumetric bone mineral density (Ct.vBMD)). Ct.Th was used in the calculation of Ct.nBUA whileQ11-1is obtained solely from ultrasound data. The values of Ct.nBUA (6.7 ± 2.2 dB MHz-1.cm-1) andQ11-1(8.6 ± 3.1%) were consistent with the literature data and were correlated to Ct.vBMD (R2=0.92,p<0.01, RMSE = 0.56 dB.MHz-1.cm-1, andR2=0.93,p<0.01, RMSE = 0.76%). This preliminary study suggests that the attenuation of an ultrasound signal propagating in cortical bone can be measuredin vivoat the one-third distal radius and that it provides an information on bone quality as attenuation values were correlated to Ct.vBMD. It remains to ascertain that Ct.nBUA andQ11-1measured here exactly reflect the true (intrinsic) ultrasonic attenuation in cortical bone. Measurement of attenuation may be considered useful for assessing bone health combined with the measurement of Ct.Th, porosity and bulk wave velocities in multimodal cortical bone QUS methods.
Collapse
Affiliation(s)
- Jean-Gabriel Minonzio
- Sorbonne Université, INSERM UMR S 1146, CNRS UMR 7371, Laboratoire d'Imagerie Biomédicale, F-75006 Paris, France.,Escuela de Ingeniería Informática, Universidad de Valparaíso, Valparaíso 2362735, Chile.,Centro de Investigación y Desarrollo en Ingeniería en Salud, Universidad de Valparaíso, Valparaíso, Chile
| | - Chao Han
- Sorbonne Université, INSERM UMR S 1146, CNRS UMR 7371, Laboratoire d'Imagerie Biomédicale, F-75006 Paris, France
| | - Didier Cassereau
- Sorbonne Université, INSERM UMR S 1146, CNRS UMR 7371, Laboratoire d'Imagerie Biomédicale, F-75006 Paris, France
| | - Quentin Grimal
- Sorbonne Université, INSERM UMR S 1146, CNRS UMR 7371, Laboratoire d'Imagerie Biomédicale, F-75006 Paris, France
| |
Collapse
|
17
|
Carlson CS, Postema M. Deep impact of superficial skin inking: acoustic analysis of underlying tissue. BIO INTEGRATION 2021; 2. [DOI: 10.15212/bioi-2021-0004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2025] Open
Abstract
Abstract
Background: Skin tattoos are a common decoration, but profound scientific study whether the presence of a skin tattoo alters the acoustic response from superficial tissue, and therefore from underlying tissue, was previously lacking. Any image aberrations caused by tattoo presence may have been thought negligible, yet empirically found artifacts in brightness-mode images of tattooed skin suggest otherwise. This study investigated the nature of these artifacts theoretically and experimentally in extremely simplified cases of perfectly flat and homogenous layered media and in tattooed pork.
Methods: Theory was derived for computing the acoustic response from horizontally and vertically layered media containing a thin inked layer. Experiments were performed in vitro. Artificial and pork skin were tattooed, attached to phantom material, and sonicated with a 13–6-MHz probe. The speed of sound of these materials was determined, and the perceived refraction angles was measured.
Results: The measured speeds of sound of tattooed materials were higher than those of their uninked counterparts. The presence of tattoo ink was found to have increased the linear acoustic attenuation by 1 dB/cm. This value is negligible for typical tattoos of only few millimeters. The perceived critical refraction angles of adjacent materials could be detected, and their corresponding speeds of sound were quantified. These coincided with values derived from theory.
Conclusion: The ratio of speeds of sound of adjacent materials was shown to create distinct highlights in brightness-mode images. The artifacts observed in in vitro and in vivo brightness-mode scans were explained from near-vertical transitions between areas of different sound speed. This is the first study correlating so-called critical refraction highlighting with speed-of-sound information. In addition, it was found that phantom material is a room-temperature acoustic alternative for experiments on live human skin. In summary, the presence of superficial tattoos has a small but quantifiable effect on the acoustic response from deeper tissues.
Collapse
|