1
|
Dencks S, Lisson T, Oblisz N, Kiessling F, Schmitz G. Ultrasound Localization Microscopy Precision of Clinical 3-D Ultrasound Systems. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2024; 71:1677-1689. [PMID: 39321018 DOI: 10.1109/tuffc.2024.3467391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/27/2024]
Abstract
Ultrasound localization microscopy (ULM) is becoming well established in preclinical applications. For its translation into clinical practice, the localization precision achievable with commercial ultrasound (US) scanners is crucial-especially with volume imaging, which is essential for dealing with out-of-plane motion. Here, we propose an easy-to-perform method to estimate the localization precision of 3-D US scanners. With this method, we evaluated imaging sequences of the Philips Epiq 7 US device using the X5-1 and the XL14-3 matrix transducers and also tested different localization methods. For the X5-1 transducer, the best lateral, elevational, and axial precision was 109, 95, and m for one contrast mode, and 29, 22, and m for the other. The higher frequency XL14-3 transducer yielded precisions of 17, 38, and m using the harmonic imaging mode. Although the center of mass was the most robust localization method also often providing the best precision, the localization method has only a minor influence on the localization precision compared to the impact by the imaging sequence and transducer. The results show that with one of the imaging modes of the X5-1 transducer, precisions comparable to the XL14-3 transducer can be achieved. However, due to localization precisions worse than m, reconstruction of the microvasculature at the capillary level will not be possible. These results show the importance of evaluating the localization precision of imaging sequences from different US transducers or scanners in all directions before using them for in vivo measurements.
Collapse
|
2
|
Coudert A, Denis L, Chavignon A, Bodard S, Naveau M, Sistiaga PP, Saulnier R, Orset C, Vivien D, Chappard C, Couture O. 3-D Transcranial Ultrasound Localization Microscopy Reveals Major Arteries in the Sheep Brain. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2024; 71:1666-1676. [PMID: 39052461 DOI: 10.1109/tuffc.2024.3432998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/27/2024]
Abstract
Cerebral circulation ensures the proper functioning of the entire human body, and its interruption, i.e., stroke, leads to irreversible damage. However, tools for observing cerebral circulation are still lacking. Although MRI and computed tomography (CT) scans serve as conventional methods, their accessibility remains a challenge, prompting exploration into alternative, portable, and nonionizing imaging solutions like ultrasound with reduced costs. While ultrasound localization microscopy (ULM) displays potential in high-resolution vessel imaging, its 2-D constraints limit its emergency utility. This study delves into the feasibility of 3-D ULM with multiplexed probe for transcranial vessel imaging in sheep brains, emulating human skull characteristics. Three sheep underwent 3-D ULM imaging, compared with angiographic MRI, while skull characterization was conducted in vivo using ultrashort bone MRI sequences and ex vivo via micro-CT. The study showcased 3-D ULM's ability to highlight vessels, down to the circle of Willis, yet within a confined 3-D field of view. Future enhancements in signal, aberration correction, and human trials hold promise for a portable, volumetric, transcranial ultrasound angiography system.
Collapse
|
3
|
Chabouh G, Denis L, Bodard S, Lager F, Renault G, Chavignon A, Couture O. Whole Organ Volumetric Sensing Ultrasound Localization Microscopy for Characterization of Kidney Structure. IEEE TRANSACTIONS ON MEDICAL IMAGING 2024; 43:4055-4063. [PMID: 38857150 DOI: 10.1109/tmi.2024.3411669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2024]
Abstract
Glomeruli are the filtration units of the kidney and their function relies heavily on their microcirculation. Despite its obvious diagnostic importance, an accurate estimation of blood flow in the capillary bundle within glomeruli defies the resolution of conventional imaging modalities. Ultrasound Localization Microscopy (ULM) has demonstrated its ability to image in-vivo deep organs in the body. Recently, the concept of sensing ULM or sULM was introduced to classify individual microbubble behavior based on the expected physiological conditions at the micrometric scale. In the kidney of both rats and humans, it revealed glomerular structures in 2D but was severely limited by planar projection. In this work, we aim to extend sULM in 3D to image the whole organ and in order to perform an accurate characterization of the entire kidney structure. The extension of sULM into the 3D domain allows better localization and more robust tracking. The 3D metrics of velocity and pathway angular shift made glomerular mask possible. This approach facilitated the quantification of glomerular physiological parameter such as an interior traveled distance of approximately 7.5 ±0.6 microns within the glomerulus. This study introduces a technique that characterize the kidney physiology which can serve as a method to facilite pathology assessment. Furthermore, its potential for clinical relevance could serve as a bridge between research and practical application, leading to innovative diagnostics and improved patient care.
Collapse
|
4
|
Saini M, Fatemi M, Alizad A. Fast inter-frame motion correction in contrast-free ultrasound quantitative microvasculature imaging using deep learning. Sci Rep 2024; 14:26161. [PMID: 39478021 PMCID: PMC11525680 DOI: 10.1038/s41598-024-77610-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2024] [Accepted: 10/23/2024] [Indexed: 11/02/2024] Open
Abstract
Contrast-free ultrasound quantitative microvasculature imaging shows promise in several applications, including the assessment of benign and malignant lesions. However, motion represents one of the major challenges in imaging tumor microvessels in organs that are prone to physiological motions. This study aims at addressing potential microvessel image degradation in in vivo human thyroid due to its proximity to carotid artery. The pulsation of the carotid artery induces inter-frame motion that significantly degrades microvasculature images, resulting in diagnostic errors. The main objective of this study is to reduce inter-frame motion artifacts in high-frame-rate ultrasound imaging to achieve a more accurate visualization of tumor microvessel features. We propose a low-complex deep learning network comprising depth-wise separable convolutional layers and hybrid adaptive and squeeze-and-excite attention mechanisms to correct inter-frame motion in high-frame-rate images. Rigorous validation using phantom and in-vivo data with simulated inter-frame motion indicates average improvements of 35% in Pearson correlation coefficients (PCCs) between motion corrected and reference data with respect to that of motion corrupted data. Further, reconstruction of microvasculature images using motion-corrected frames demonstrates PCC improvement from 31 to 35%. Another thorough validation using in-vivo thyroid data with physiological inter-frame motion demonstrates average improvement of 20% in PCC and 40% in mean inter-frame correlation. Finally, comparison with the conventional image registration method indicates the suitability of proposed network for real-time inter-frame motion correction with 5000 times reduction in motion corrected frame prediction latency.
Collapse
Affiliation(s)
- Manali Saini
- Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN, 55905, USA
| | - Mostafa Fatemi
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN, 55905, USA
| | - Azra Alizad
- Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN, 55905, USA.
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN, 55905, USA.
| |
Collapse
|
5
|
Arendt Jensen J, Amin Naji M, Kazmarek PraeSius S, Taghavi I, Schou M, Naur Hansen L, Bech Andersen S, Byrholdt Sogaard S, Sarup Panduro N, Mehlin Sorensen C, Bachmann Nielsen M, Gundlach C, Martin Kjer H, Bjorholm Dahl A, Gueorguiev Tomov B, Lind Ommen M, Bent Larsen N, Vilain Thomsen E. Super-Resolution Ultrasound Imaging Using the Erythrocytes-Part I: Density Images. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2024; 71:925-944. [PMID: 38857145 DOI: 10.1109/tuffc.2024.3411711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2024]
Abstract
A new approach for vascular super-resolution (SR) imaging using the erythrocytes as targets (SUper-Resolution ultrasound imaging of Erythrocytes (SURE) imaging) is described and investigated. SURE imaging does not require fragile contrast agent bubbles, making it possible to use the maximum allowable mechanical index (MI) for ultrasound scanning for an increased penetration depth. A synthetic aperture (SA) ultrasound sequence was employed with 12 virtual sources (VSs) using a 10-MHz GE L8-18i-D linear array hockey stick probe. The axial resolution was [Formula: see text]m) and the lateral resolution was [Formula: see text]m). Field IIpro simulations were conducted on 12.5- μ m radius vessel pairs with varying separations. A vessel pair with a separation of 70 μ m could be resolved, indicating a SURE image resolution below half a wavelength. A Verasonics research scanner was used for the in vivo experiments to scan the kidneys of Sprague-Dawley rats for up to 46 s to visualize their microvasculature by processing from 0.1 up to 45 s of data for SURE imaging and for 46.8 s for SR imaging with a SonoVue contrast agent. Afterward, the renal vasculature was filled with the ex vivo micro-computed tomography (CT) contrast agent Microfil, excised, and scanned in a micro-CT scanner at both a 22.6- μ m voxel size for 11 h and for 20 h in a 5- μ m voxel size for validating the SURE images. Comparing the SURE and micro-CT images revealed that vessels with a diameter of 28 μ m, five times smaller than the ultrasound wavelength, could be detected, and the dense grid of microvessels in the full kidney was shown for scan times between 1 and 10 s. The vessel structure in the cortex was also similar to the SURE and SR images. Fourier ring correlation (FRC) indicated a resolution capability of 29 μ m. SURE images are acquired in seconds rather than minutes without any patient preparation or contrast injection, making the method translatable to clinical use.
Collapse
|
6
|
Naji MA, Taghavi I, Schou M, Praesius SK, Hansen LN, Panduro NS, Andersen SB, Sogaard SB, Gundlach C, Kjer HM, Tomov BG, Thomsen EV, Nielsen MB, Larsen NB, Dahl AB, Sorensen CM, Jensen JA. Super-Resolution Ultrasound Imaging Using the Erythrocytes-Part II: Velocity Images. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2024; 71:945-959. [PMID: 38857146 DOI: 10.1109/tuffc.2024.3411795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2024]
Abstract
Super-resolution ultrasound imaging using the erythrocytes (SURE) has recently been introduced. The method uses erythrocytes as targets instead of fragile microbubbles (MBs). The abundance of erythrocyte scatterers makes it possible to acquire SURE data in just a few seconds compared with several minutes in ultrasound localization microscopy (ULM) using MBs. A high number of scatterers can reduce the acquisition time; however, the tracking of uncorrelated and high-density scatterers is quite challenging. This article hypothesizes that it is possible to detect and track erythrocytes as targets to obtain vascular flow images. A SURE tracking pipeline is used with modules for beamforming, recursive synthetic aperture (SA) imaging, motion estimation, echo canceling, peak detection, and recursive nearest-neighbor (NN) tracker. The SURE tracking pipeline is capable of distinguishing the flow direction and separating tubes of a simulated Field II phantom with 125-25- [Formula: see text] wall-to-wall tube distances, as well as a 3-D printed hydrogel micr-flow phantom with 100-60- [Formula: see text] wall-to-wall channel distances. The comparison of an in vivo SURE scan of a Sprague-Dawley rat kidney with ULM and micro-computed tomography (CT) scans with voxel sizes of 26.5 and [Formula: see text] demonstrated consistent findings. A microvascular structure composed of 16 vessels exhibited similarities across all imaging modalities. The flow direction and velocity profiles in the SURE scan were found to be concordant with those from ULM.
Collapse
|
7
|
Hansen-Shearer J, Yan J, Lerendegui M, Huang B, Toulemonde M, Riemer K, Tan Q, Tonko J, Weinberg PD, Dunsby C, Tang MX. Ultrafast 3-D Transcutaneous Super Resolution Ultrasound Using Row-Column Array Specific Coherence-Based Beamforming and Rolling Acoustic Sub-aperture Processing: In Vitro, in Rabbit and in Human Study. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:1045-1057. [PMID: 38702285 DOI: 10.1016/j.ultrasmedbio.2024.03.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Revised: 03/27/2024] [Accepted: 03/31/2024] [Indexed: 05/06/2024]
Abstract
OBJECTIVE This study aimed to realise 3-D super-resolution ultrasound imaging transcutaneously with a row-column array which has far fewer independent electronic channels and a wider field of view than typical fully addressed 2-D matrix arrays. The in vivo image quality of the row-column array is generally poor, particularly when imaging non-invasively. This study aimed to develop a suite of image formation and post-processing methods to improve image quality and demonstrate the feasibility of ultrasound localisation microscopy using a row-column array, transcutaneously on a rabbit model and in a human. METHODS To achieve this, a processing pipeline was developed which included a new type of rolling window image reconstruction, which integrated a row-column array specific coherence-based beamforming technique with acoustic sub-aperture processing. This and other processing steps reduced the 'secondary' lobe artefacts, and noise and increased the effective frame rate, thereby enabling ultrasound localisation images to be produced. RESULTS Using an in vitro cross tube, it was found that the procedure reduced the percentage of 'false' locations from ∼26% to ∼15% compared to orthogonal plane wave compounding. Additionally, it was found that the noise could be reduced by ∼7 dB and the effective frame rate was increased to over 4000 fps. In vivo, ultrasound localisation microscopy was used to produce images non-invasively of a rabbit kidney and a human thyroid. CONCLUSION It has been demonstrated that the proposed methods using a row-column array can produce large field of view super-resolution microvascular images in vivo and in a human non-invasively.
Collapse
|
8
|
Yan J, Huang B, Tonko J, Toulemonde M, Hansen-Shearer J, Tan Q, Riemer K, Ntagiantas K, Chowdhury RA, Lambiase PD, Senior R, Tang MX. Transthoracic ultrasound localization microscopy of myocardial vasculature in patients. Nat Biomed Eng 2024; 8:689-700. [PMID: 38710839 PMCID: PMC11250254 DOI: 10.1038/s41551-024-01206-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Accepted: 03/30/2024] [Indexed: 05/08/2024]
Abstract
Myocardial microvasculature and haemodynamics are indicative of potential microvascular diseases for patients with symptoms of coronary heart disease in the absence of obstructive coronary arteries. However, imaging microvascular structure and flow within the myocardium is challenging owing to the small size of the vessels and the constant movement of the patient's heart. Here we show the feasibility of transthoracic ultrasound localization microscopy for imaging myocardial microvasculature and haemodynamics in explanted pig hearts and in patients in vivo. Through a customized data-acquisition and processing pipeline with a cardiac phased-array probe, we leveraged motion correction and tracking to reconstruct the dynamics of microcirculation. For four patients, two of whom had impaired myocardial function, we obtained super-resolution images of myocardial vascular structure and flow using data acquired within a breath hold. Myocardial ultrasound localization microscopy may facilitate the understanding of myocardial microcirculation and the management of patients with cardiac microvascular diseases.
Collapse
Affiliation(s)
- Jipeng Yan
- Ultrasound Lab for Imaging and Sensing, Department of Bioengineering, Imperial College London, London, UK
| | - Biao Huang
- Ultrasound Lab for Imaging and Sensing, Department of Bioengineering, Imperial College London, London, UK
| | - Johanna Tonko
- Institute of Cardiovascular Science, University College London, London, UK
| | - Matthieu Toulemonde
- Ultrasound Lab for Imaging and Sensing, Department of Bioengineering, Imperial College London, London, UK
| | - Joseph Hansen-Shearer
- Ultrasound Lab for Imaging and Sensing, Department of Bioengineering, Imperial College London, London, UK
| | - Qingyuan Tan
- Ultrasound Lab for Imaging and Sensing, Department of Bioengineering, Imperial College London, London, UK
| | - Kai Riemer
- Ultrasound Lab for Imaging and Sensing, Department of Bioengineering, Imperial College London, London, UK
| | | | - Rasheda A Chowdhury
- Faculty of Medicine, National Heart and Lung Institute, Imperial College London, London, UK
| | - Pier D Lambiase
- Institute of Cardiovascular Science, University College London, London, UK
| | - Roxy Senior
- Faculty of Medicine, National Heart and Lung Institute, Imperial College London, London, UK
- Royal Brompton Hospital, London, UK
- Northwick Park Hospital, Harrow, UK
| | - Meng-Xing Tang
- Ultrasound Lab for Imaging and Sensing, Department of Bioengineering, Imperial College London, London, UK.
| |
Collapse
|
9
|
Porte C, Lisson T, Kohlen M, von Maltzahn F, Dencks S, von Stillfried S, Piepenbrock M, Rix A, Dasgupta A, Koczera P, Boor P, Stickeler E, Schmitz G, Kiessling F. Ultrasound Localization Microscopy for Breast Cancer Imaging in Patients: Protocol Optimization and Comparison with Shear Wave Elastography. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:57-66. [PMID: 37805359 DOI: 10.1016/j.ultrasmedbio.2023.09.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2023] [Revised: 07/25/2023] [Accepted: 09/02/2023] [Indexed: 10/09/2023]
Abstract
OBJECTIVE Ultrasound localization microscopy (ULM) has gained increasing attention in recent years because of its ability to visualize blood vessels at super-resolution. The field of oncology, in particular, could benefit from detailed vascular characterization, for example, for diagnosis and therapy monitoring. This study was aimed at refining ULM for breast cancer patients by optimizing the measurement protocol, identifying translational challenges and combining ULM and shear wave elastography. METHODS We computed ULM images of 11 patients with breast cancer by recording contrast-enhanced ultrasound (CEUS) sequences and post-processing them in an offline pipeline. For CEUS, two different doses and injection speeds of SonoVue were applied. The best injection protocol was determined based on quantitative parameters derived from so-called occurrence maps. In addition, a suitable measurement time window was determined, also considering the occurrence of motion. ULM results were compared with shear wave elastography and histological vessel density. RESULTS At the higher dose and injection speed, the highest number of microbubbles, number of tracks and vessel coverage were achieved, leading to the most detailed representation of tumor vasculature. Even at the highest concentration, no significant overlay of microbubble signals occurred. Motion significantly reduced the number of usable frames, thus limiting the measurement window to 3.5 min. ULM vessel coverage was comparable to the histological vessel fraction and correlated significantly with mean tumor elasticity. CONCLUSION The settings for microbubble injection strongly influence ULM images, thus requiring optimized protocols for different indications. Patient and examiner motion was identified as the main translational challenge for ULM.
Collapse
Affiliation(s)
- Céline Porte
- Institute for Experimental Molecular Imaging, University Clinic Aachen, RWTH Aachen University, Aachen, Germany
| | - Thomas Lisson
- Department of Electrical Engineering and Information Technology, Ruhr University Bochum, Bochum, Germany
| | - Matthias Kohlen
- Department of Gynecology and Obstetrics, University Clinic Aachen, RWTH Aachen University, Aachen, Germany
| | - Finn von Maltzahn
- Institute for Experimental Molecular Imaging, University Clinic Aachen, RWTH Aachen University, Aachen, Germany
| | - Stefanie Dencks
- Department of Electrical Engineering and Information Technology, Ruhr University Bochum, Bochum, Germany
| | - Saskia von Stillfried
- Institute of Pathology, University Clinic Aachen, RWTH Aachen University, Aachen, Germany
| | - Marion Piepenbrock
- Department of Electrical Engineering and Information Technology, Ruhr University Bochum, Bochum, Germany
| | - Anne Rix
- Institute for Experimental Molecular Imaging, University Clinic Aachen, RWTH Aachen University, Aachen, Germany
| | - Anshuman Dasgupta
- Institute for Experimental Molecular Imaging, University Clinic Aachen, RWTH Aachen University, Aachen, Germany
| | - Patrick Koczera
- Institute for Experimental Molecular Imaging, University Clinic Aachen, RWTH Aachen University, Aachen, Germany
| | - Peter Boor
- Institute of Pathology, University Clinic Aachen, RWTH Aachen University, Aachen, Germany
| | - Elmar Stickeler
- Department of Gynecology and Obstetrics, University Clinic Aachen, RWTH Aachen University, Aachen, Germany
| | - Georg Schmitz
- Department of Electrical Engineering and Information Technology, Ruhr University Bochum, Bochum, Germany
| | - Fabian Kiessling
- Institute for Experimental Molecular Imaging, University Clinic Aachen, RWTH Aachen University, Aachen, Germany; Fraunhofer Institute for Digital Medicine MEVIS, Aachen, Germany.
| |
Collapse
|
10
|
Søgaard SB, Andersen SB, Taghavi I, Schou M, Christoffersen C, Jacobsen JCB, Kjer HM, Gundlach C, McDermott A, Jensen JA, Nielsen MB, Sørensen CM. Super-Resolution Ultrasound Imaging of Renal Vascular Alterations in Zucker Diabetic Fatty Rats during the Development of Diabetic Kidney Disease. Diagnostics (Basel) 2023; 13:3197. [PMID: 37892017 PMCID: PMC10605617 DOI: 10.3390/diagnostics13203197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2023] [Revised: 10/08/2023] [Accepted: 10/11/2023] [Indexed: 10/29/2023] Open
Abstract
Individuals with diabetes at risk of developing diabetic kidney disease (DKD) are challenging to identify using currently available clinical methods. Prognostic accuracy and initiation of treatment could be improved by a quantification of the renal microvascular rarefaction and the increased vascular tortuosity during the development of DKD. Super-resolution ultrasound (SRUS) imaging is an in vivo technique capable of visualizing blood vessels at sizes below 75 µm. This preclinical study aimed to investigate the alterations in renal blood vessels' density and tortuosity in a type 2 diabetes rat model, Zucker diabetic fatty (ZDF) rats, as a prediction of DKD. Lean age-matched Zucker rats were used as controls. A total of 36 rats were studied, subdivided into ages of 12, 22, and 40 weeks. Measured albuminuria indicated the early stage of DKD, and the SRUS was compared with the ex vivo micro-computed tomography (µCT) of the same kidneys. Assessed using the SRUS imaging, a significantly decreased cortical vascular density was detected in the ZDF rats from 22 weeks of age compared to the healthy controls, concomitant with a significantly increased albuminuria. Already by week 12, a trend towards a decreased cortical vascular density was found prior to the increased albuminuria. The quantified vascular density in µCT corresponded with the in vivo SRUS imaging, presenting a consistently lower vascular density in the ZDF rats. Regarding vessel tortuosity, an overall trend towards an increased tortuosity was present in the ZDF rats. SRUS shows promise for becoming an additional tool for monitoring and prognosing DKD. In the future, large-scale animal studies and human trials are needed for confirmation.
Collapse
Affiliation(s)
- Stinne Byrholdt Søgaard
- Department of Biomedical Sciences, University of Copenhagen, 2200 Copenhagen, Denmark; (S.B.S.); (S.B.A.); (C.C.); (J.C.B.J.); (A.M.)
- Department of Diagnostic Radiology, Rigshospitalet, 2100 Copenhagen, Denmark;
| | - Sofie Bech Andersen
- Department of Biomedical Sciences, University of Copenhagen, 2200 Copenhagen, Denmark; (S.B.S.); (S.B.A.); (C.C.); (J.C.B.J.); (A.M.)
- Department of Diagnostic Radiology, Rigshospitalet, 2100 Copenhagen, Denmark;
| | - Iman Taghavi
- Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, 2800 Lyngby, Denmark; (I.T.); (J.A.J.)
| | | | - Christina Christoffersen
- Department of Biomedical Sciences, University of Copenhagen, 2200 Copenhagen, Denmark; (S.B.S.); (S.B.A.); (C.C.); (J.C.B.J.); (A.M.)
- Department of Clinical Biochemistry, Rigshospitalet, 2100 Copenhagen, Denmark
| | - Jens Christian Brings Jacobsen
- Department of Biomedical Sciences, University of Copenhagen, 2200 Copenhagen, Denmark; (S.B.S.); (S.B.A.); (C.C.); (J.C.B.J.); (A.M.)
| | - Hans Martin Kjer
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, 2800 Lyngby, Denmark;
| | - Carsten Gundlach
- Department of Physics, Technical University of Denmark, 2800 Lyngby, Denmark;
| | - Amy McDermott
- Department of Biomedical Sciences, University of Copenhagen, 2200 Copenhagen, Denmark; (S.B.S.); (S.B.A.); (C.C.); (J.C.B.J.); (A.M.)
| | - Jørgen Arendt Jensen
- Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, 2800 Lyngby, Denmark; (I.T.); (J.A.J.)
| | - Michael Bachmann Nielsen
- Department of Diagnostic Radiology, Rigshospitalet, 2100 Copenhagen, Denmark;
- Department of Clinical Medicine, University of Copenhagen, 2200 Copenhagen, Denmark
| | - Charlotte Mehlin Sørensen
- Department of Biomedical Sciences, University of Copenhagen, 2200 Copenhagen, Denmark; (S.B.S.); (S.B.A.); (C.C.); (J.C.B.J.); (A.M.)
| |
Collapse
|
11
|
Jensen JA, Tomov BG, Haslund LE, Panduro NS, Sorensen CM. Universal Synthetic Aperture Sequence for Anatomic, Functional, and Super Resolution Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2023; 70:708-720. [PMID: 37247313 DOI: 10.1109/tuffc.2023.3280803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Synthetic aperture (SA) can be used for both anatomic and functional imaging, where tissue motion and blood velocity are revealed. Often, sequences optimized for anatomic B-mode imaging are different from functional sequences, as the best distribution and number of emissions are different. B-mode sequences demand many emissions for a high contrast, whereas flow sequences demand short sequences for high correlations yielding accurate velocity estimates. This article hypothesizes that a single, universal sequence can be developed for linear array SA imaging. This sequence yields high-quality linear and nonlinear B-mode images as well as accurate motion and flow estimates for high and low blood velocities and super-resolution images. Interleaved sequences with positive and negative pulse emissions for the same spherical virtual source were used to enable flow estimation for high velocities and make continuous long acquisitions for low-velocity estimation. An optimized pulse inversion (PI) sequence with 2 ×12 virtual sources was implemented for four different linear array probes connected to either a Verasonics Vantage 256 scanner or the SARUS experimental scanner. The virtual sources were evenly distributed over the whole aperture and permuted in emission order for making flow estimation possible using 4, 8, or 12 virtual sources. The frame rate was 208 Hz for fully independent images for a pulse repetition frequency of 5 kHz, and recursive imaging yielded 5000 images per second. Data were acquired from a phantom mimicking the carotid artery with pulsating flow and the kidney of a Sprague-Dawley rat. Examples include anatomic high contrast B-mode, non-linear B-mode, tissue motion, power Doppler, color flow mapping (CFM), vector velocity imaging, and super-resolution imaging (SRI) derived from the same dataset and demonstrate that all imaging modes can be shown retrospectively and quantitative data derived from it.
Collapse
|
12
|
Andersen SB, Sørensen CM, Jensen JA, Nielsen MB. Microvascular Imaging with Super-Resolution Ultrasound. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2022; 43:543-547. [PMID: 36470255 DOI: 10.1055/a-1937-6868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
|
13
|
Jensen JA, Schou M, Jorgensen LT, Tomov BG, Stuart MB, Traberg MS, Taghavi I, Oygaard SH, Ommen ML, Steenberg K, Thomsen EV, Panduro NS, Nielsen MB, Sorensen CM. Anatomic and Functional Imaging Using Row-Column Arrays. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:2722-2738. [PMID: 35839193 DOI: 10.1109/tuffc.2022.3191391] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Row-column (RC) arrays have the potential to yield full 3-D ultrasound imaging with a greatly reduced number of elements compared to fully populated arrays. They, however, have several challenges due to their special geometry. This review article summarizes the current literature for RC imaging and demonstrates that full anatomic and functional imaging can attain a high quality using synthetic aperture (SA) sequences and modified delay-and-sum beamforming. Resolution can approach the diffraction limit with an isotropic resolution of half a wavelength with low sidelobe levels, and the field of view can be expanded by using convex or lensed RC probes. GPU beamforming allows for three orthogonal planes to be beamformed at 30 Hz, providing near real-time imaging ideal for positioning the probe and improving the operator's workflow. Functional imaging is also attainable using transverse oscillation and dedicated SA sequence for tensor velocity imaging for revealing the full 3-D velocity vector as a function of spatial position and time for both blood velocity and tissue motion estimation. Using RC arrays with commercial contrast agents can reveal super-resolution imaging (SRI) with isotropic resolution below [Formula: see text]. RC arrays can, thus, yield full 3-D imaging at high resolution, contrast, and volumetric rates for both anatomic and functional imaging with the same number of receive channels as current commercial 1-D arrays.
Collapse
|
14
|
Søgaard SB, Andersen SB, Taghavi I, Hoyos CAV, Christoffersen C, Hansen KL, Jensen JA, Nielsen MB, Sørensen CM. Super-Resolution Ultrasound Imaging Provides Quantification of the Renal Cortical and Medullary Vasculature in Obese Zucker Rats: A Pilot Study. Diagnostics (Basel) 2022; 12:diagnostics12071626. [PMID: 35885531 PMCID: PMC9318608 DOI: 10.3390/diagnostics12071626] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 06/17/2022] [Accepted: 07/01/2022] [Indexed: 11/16/2022] Open
Abstract
Obesity is a risk factor of chronic kidney disease (CKD), leading to alterations in the renal vascular structure. This study tested if renal vascular density and tortuosity was quantifiable in vivo in obese rats using microbubble-based super-resolution ultrasound imaging. The kidneys of two 11-week-old and two 20-week-old male obese Zucker rats were compared with age-matched male lean Zucker rats. The super-resolution ultrasound images were manually divided into inner medulla, outer medulla, and cortex, and each area was subdivided into arteries and veins. We quantified vascular density and tortuosity, number of detected microbubbles, and generated tracks. For comparison, we assessed glomerular filtration rate, albumin/creatinine ratio, and renal histology to evaluate CKD. The number of detected microbubbles and generated tracks varied between animals and significantly affected quantification of vessel density. In areas with a comparable number of tracks, density increased in the obese animals, concomitant with a decrease in glomerular filtration rate and an increase in albumin/creatinine ratio, but without any pathology in the histological staining. The results indicate that super-resolution ultrasound imaging can be used to quantify structural alterations in the renal vasculature. Techniques to generate more comparable number of microbubble tracks and confirmation of the findings in larger-scale studies are needed.
Collapse
Affiliation(s)
- Stinne Byrholdt Søgaard
- Department of Diagnostic Radiology, Rigshospitalet, 2100 Copenhagen, Denmark; (S.B.A.); (K.L.H.); (M.B.N.)
- Department of Biomedical Sciences, University of Copenhagen, 2200 Copenhagen, Denmark; (C.C.); (C.M.S.)
- Department of Clinical Medicine, University of Copenhagen, 2200 Copenhagen, Denmark
- Correspondence:
| | - Sofie Bech Andersen
- Department of Diagnostic Radiology, Rigshospitalet, 2100 Copenhagen, Denmark; (S.B.A.); (K.L.H.); (M.B.N.)
- Department of Biomedical Sciences, University of Copenhagen, 2200 Copenhagen, Denmark; (C.C.); (C.M.S.)
| | - Iman Taghavi
- Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, 2800 Lyngby, Denmark; (I.T.); (J.A.J.)
| | | | - Christina Christoffersen
- Department of Biomedical Sciences, University of Copenhagen, 2200 Copenhagen, Denmark; (C.C.); (C.M.S.)
- Department of Clinical Biochemistry, Rigshospitalet, 2100 Copenhagen, Denmark
| | - Kristoffer Lindskov Hansen
- Department of Diagnostic Radiology, Rigshospitalet, 2100 Copenhagen, Denmark; (S.B.A.); (K.L.H.); (M.B.N.)
- Department of Clinical Medicine, University of Copenhagen, 2200 Copenhagen, Denmark
| | - Jørgen Arendt Jensen
- Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, 2800 Lyngby, Denmark; (I.T.); (J.A.J.)
| | - Michael Bachmann Nielsen
- Department of Diagnostic Radiology, Rigshospitalet, 2100 Copenhagen, Denmark; (S.B.A.); (K.L.H.); (M.B.N.)
- Department of Clinical Medicine, University of Copenhagen, 2200 Copenhagen, Denmark
| | - Charlotte Mehlin Sørensen
- Department of Biomedical Sciences, University of Copenhagen, 2200 Copenhagen, Denmark; (C.C.); (C.M.S.)
| |
Collapse
|
15
|
Taghavi I, Andersen SB, Hoyos CAV, Schou M, Gran F, Hansen KL, Nielsen MB, Sørensen CM, Stuart MB, Jensen JA. Ultrasound super-resolution imaging with a hierarchical Kalman tracker. ULTRASONICS 2022; 122:106695. [PMID: 35149256 DOI: 10.1016/j.ultras.2022.106695] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 11/18/2021] [Accepted: 01/19/2022] [Indexed: 06/14/2023]
Abstract
Microbubble (MB) tracking plays an important role in ultrasound super-resolution imaging (SRI) by enabling velocity estimation and improving image quality. This work presents a new hierarchical Kalman (HK) tracker to achieve better performance at scenarios with high concentrations of MBs and high localization uncertainty. The method attempts to follow MBs with different velocity ranges using different Kalman filters. An extended simulation framework for evaluating trackers is also presented and used for comparison of the proposed HK tracker with the nearest-neighbor (NN) and Kalman (K) trackers. The HK tracks were most similar to the ground truth with the highest Jaccard similarity coefficient in 79% of the scenarios and the lowest root-mean-square error in 72% of the scenarios. The HK tracker reconstructed vessels with a more accurate diameter. In a scenario with an uncertainty of 51.2μm in MB localization, a vessel diameter of 250μm was estimated as 257μm by HK tracker, compared with 329μm and 389μm for the K and NN trackers. In the same scenario, the HK tracker estimated MB velocities with a relative bias down to 1.7% and a relative standard deviation down to 8.3%. Finally, the different tracking techniques were applied to in vivo data from rat kidneys, and trends similar to the simulations were observed. Conclusively, the results showed an improvement in tracking performance, when the HK tracker was employed in comparison with the NN and K trackers.
Collapse
Affiliation(s)
- Iman Taghavi
- Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, DK 2800, Kgs. Lyngby Denmark.
| | - Sofie Bech Andersen
- Department of Biomedical Sciences, University of Copenhagen, DK 2200, Copenhagen, Denmark; Department of Diagnostic Radiology, Rigshospitalet, DK 2100, Copenhagen, Denmark; Department of Clinical Medicine, University of Copenhagen, DK 2200, Copenhagen, Denmark.
| | | | - Mikkel Schou
- Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, DK 2800, Kgs. Lyngby Denmark.
| | | | - Kristoffer Lindskov Hansen
- Department of Diagnostic Radiology, Rigshospitalet, DK 2100, Copenhagen, Denmark; Department of Clinical Medicine, University of Copenhagen, DK 2200, Copenhagen, Denmark.
| | - Michael Bachmann Nielsen
- Department of Diagnostic Radiology, Rigshospitalet, DK 2100, Copenhagen, Denmark; Department of Clinical Medicine, University of Copenhagen, DK 2200, Copenhagen, Denmark.
| | | | - Matthias Bo Stuart
- Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, DK 2800, Kgs. Lyngby Denmark.
| | - Jørgen Arendt Jensen
- Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, DK 2800, Kgs. Lyngby Denmark.
| |
Collapse
|
16
|
Andersen SB, Taghavi I, Søgaard SB, Hoyos CAV, Nielsen MB, Jensen JA, Sørensen CM. Super-Resolution Ultrasound Imaging Can Quantify Alterations in Microbubble Velocities in the Renal Vasculature of Rats. Diagnostics (Basel) 2022; 12:1111. [PMID: 35626267 PMCID: PMC9140053 DOI: 10.3390/diagnostics12051111] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Revised: 04/04/2022] [Accepted: 04/27/2022] [Indexed: 11/17/2022] Open
Abstract
Super-resolution ultrasound imaging, based on the localization and tracking of single intravascular microbubbles, makes it possible to map vessels below 100 µm. Microbubble velocities can be estimated as a surrogate for blood velocity, but their clinical potential is unclear. We investigated if a decrease in microbubble velocity in the arterial and venous beds of the renal cortex, outer medulla, and inner medulla was detectable after intravenous administration of the α1-adrenoceptor antagonist prazosin. The left kidneys of seven rats were scanned with super-resolution ultrasound for 10 min before, during, and after prazosin administration using a bk5000 ultrasound scanner and hockey-stick probe. The super-resolution images were manually segmented, separating cortex, outer medulla, and inner medulla. Microbubble tracks from arteries/arterioles were separated from vein/venule tracks using the arterial blood flow direction. The mean microbubble velocities from each scan were compared. This showed a significant prazosin-induced velocity decrease only in the cortical arteries/arterioles (from 1.59 ± 0.38 to 1.14 ± 0.31 to 1.18 ± 0.33 mm/s, p = 0.013) and outer medulla descending vasa recta (from 0.70 ± 0.05 to 0.66 ± 0.04 to 0.69 ± 0.06 mm/s, p = 0.026). Conclusively, super-resolution ultrasound imaging makes it possible to detect and differentiate microbubble velocity responses to prazosin simultaneously in the renal cortical and medullary vascular beds.
Collapse
Affiliation(s)
- Sofie Bech Andersen
- Department of Biomedical Sciences, University of Copenhagen, 2200 Copenhagen, Denmark; (S.B.S.); (C.M.S.)
- Department of Diagnostic Radiology, University Hospital Rigshospitalet, 2100 Copenhagen, Denmark;
| | - Iman Taghavi
- Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, 2800 Lyngby, Denmark; (I.T.); (J.A.J.)
| | - Stinne Byrholdt Søgaard
- Department of Biomedical Sciences, University of Copenhagen, 2200 Copenhagen, Denmark; (S.B.S.); (C.M.S.)
- Department of Diagnostic Radiology, University Hospital Rigshospitalet, 2100 Copenhagen, Denmark;
| | | | - Michael Bachmann Nielsen
- Department of Diagnostic Radiology, University Hospital Rigshospitalet, 2100 Copenhagen, Denmark;
- Department of Clinical Medicine, University of Copenhagen, 2200 Copenhagen, Denmark
| | - Jørgen Arendt Jensen
- Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, 2800 Lyngby, Denmark; (I.T.); (J.A.J.)
| | - Charlotte Mehlin Sørensen
- Department of Biomedical Sciences, University of Copenhagen, 2200 Copenhagen, Denmark; (S.B.S.); (C.M.S.)
| |
Collapse
|
17
|
Qiu L, Zhang J, Yang Y, Zhang H, Lee FF, He Q, Huang C, Huang L, Qian L, Luo J. In Vivo assessment of hypertensive nephrosclerosis using ultrasound localization microscopy. Med Phys 2022; 49:2295-2308. [PMID: 35218672 DOI: 10.1002/mp.15583] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Revised: 01/27/2022] [Accepted: 02/21/2022] [Indexed: 11/07/2022] Open
Abstract
PURPOSE As a typical chronic kidney disease (CKD), hypertensive nephrosclerosis (HN) is a common syndrome of hypertension, characterized by chronic kidney microvascular damage. Early diagnosis of microvascular damage using conventional ultrasound imaging encounters challenges in sensitivity and specificity owing to the inherent diffraction limit. Ultrasound localization microscopy (ULM) has been developed to obtain microvasculature and microvascular hemodynamics within the kidney, and would be a promising tool for early diagnosis of CKD. METHODS In this study, the advantage of quantitative indexes obtained by using ULM (mean arterial blood flow speeds of different segments of interlobular arteries) over indexes obtained using conventional clinical serum (β2-microglobulin, serum urea nitrogen and creatinine) and urine (24-hour urine volume and urine protein) tests and ultrasound Doppler imaging [peak systolic velocity (PSV), end-diastolic velocity (EDV) and resistance index (RI)] and contrast-enhanced ultrasound imaging [CEUS; rise time (RT), peak intensity (IMAX), mean transit time (mTT) and area under the time-intensity curve (AUC)] for early diagnosis of HN was investigated. Examinations were carried out on 6 spontaneously hypertensive rats (SHR) and 5 normal Wistar-Kyoto (WKY) rats at the age of 10 weeks. RESULTS The experimental results showed that the indicators derived from conventional clinical inspections (serum and urine tests) and ultrasound imaging (PSV, EDV, RI, RT, IMAX, mTT and AUC) did not show significant difference between hypertensive and healthy rats (p > 0.05), while the TTP of the SHR group (28.52 ± 5.52 s) derived from CEUS is significantly higher than that of the WKY group (18.68 ± 7.32 s; p < 0.05). The mean blood flow speed in interlobular artery of SHR (12.47 ± 1.06 mm/s) derived from ULM is significantly higher than that of WKY rats (10.13 ± 1.17 mm/s; p < 0.01). CONCLUSION The advantages of ULM over conventional clinical inspections and ultrasound imaging methods for early diagnosis of HN were validated. The quantitative results showed that ULM can effectively diagnose HN at the early stage by detecting the blood flow speed changes of interlobular arteries. ULM may promise a reliable technique for early diagnosis of HN in the future. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Lanyan Qiu
- Department of Ultrasound, Beijing Friendship Hospital, Capital Medical University, Beijing, 100050, China
| | - Jingke Zhang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China
| | - Yi Yang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China
| | - Hong Zhang
- Department of Ultrasound, Beijing Friendship Hospital, Capital Medical University, Beijing, 100050, China
| | - Fu-Feng Lee
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China
| | - Qiong He
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China.,Tsinghua-Peking Joint Center for Life Sciences, Tsinghua University, Beijing, 100084, China
| | - Chengwu Huang
- Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN, 55905, USA
| | - Lijie Huang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China
| | - Linxue Qian
- Department of Ultrasound, Beijing Friendship Hospital, Capital Medical University, Beijing, 100050, China
| | - Jianwen Luo
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China
| |
Collapse
|
18
|
Andersen SB, Taghavi I, Kjer HM, Søgaard SB, Gundlach C, Dahl VA, Nielsen MB, Dahl AB, Jensen JA, Sørensen CM. Evaluation of 2D super-resolution ultrasound imaging of the rat renal vasculature using ex vivo micro-computed tomography. Sci Rep 2021; 11:24335. [PMID: 34934089 PMCID: PMC8692475 DOI: 10.1038/s41598-021-03726-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Accepted: 12/08/2021] [Indexed: 11/29/2022] Open
Abstract
Super-resolution ultrasound imaging (SRUS) enables in vivo microvascular imaging of deeper-lying tissues and organs, such as the kidneys or liver. The technique allows new insights into microvascular anatomy and physiology and the development of disease-related microvascular abnormalities. However, the microvascular anatomy is intricate and challenging to depict with the currently available imaging techniques, and validation of the microvascular structures of deeper-lying organs obtained with SRUS remains difficult. Our study aimed to directly compare the vascular anatomy in two in vivo 2D SRUS images of a Sprague-Dawley rat kidney with ex vivo μCT of the same kidney. Co-registering the SRUS images to the μCT volume revealed visually very similar vascular features of vessels ranging from ~ 100 to 1300 μm in diameter and illustrated a high level of vessel branching complexity captured in the 2D SRUS images. Additionally, it was shown that it is difficult to use μCT data of a whole rat kidney specimen to validate the super-resolution capability of our ultrasound scans, i.e., validating the actual microvasculature of the rat kidney. Lastly, by comparing the two imaging modalities, fundamental challenges for 2D SRUS were demonstrated, including the complexity of projecting a 3D vessel network into 2D. These challenges should be considered when interpreting clinical or preclinical SRUS data in future studies.
Collapse
Affiliation(s)
- Sofie Bech Andersen
- Department of Biomedical Sciences, University of Copenhagen, 2200, Copenhagen, Denmark.
- Department of Radiology, Rigshospitalet, 2100, Copenhagen, Denmark.
| | - Iman Taghavi
- Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, 2800, Lyngby, Denmark
| | - Hans Martin Kjer
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, 2800, Lyngby, Denmark
| | - Stinne Byrholdt Søgaard
- Department of Biomedical Sciences, University of Copenhagen, 2200, Copenhagen, Denmark
- Department of Radiology, Rigshospitalet, 2100, Copenhagen, Denmark
| | - Carsten Gundlach
- Department of Physics, Technical University of Denmark, 2800, Lyngby, Denmark
| | - Vedrana Andersen Dahl
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, 2800, Lyngby, Denmark
| | - Michael Bachmann Nielsen
- Department of Radiology, Rigshospitalet, 2100, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, 2200, Copenhagen, Denmark
| | - Anders Bjorholm Dahl
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, 2800, Lyngby, Denmark
| | - Jørgen Arendt Jensen
- Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, 2800, Lyngby, Denmark
| | | |
Collapse
|