1
|
Isenberg BC, Vedula EM, Santos J, Lewis DJ, Roberts TR, Harea G, Sutherland D, Landis B, Blumenstiel S, Urban J, Lang D, Teece B, Lai W, Keating R, Chiang D, Batchinsky AI, Borenstein JT. A Clinical-Scale Microfluidic Respiratory Assist Device with 3D Branching Vascular Networks. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2207455. [PMID: 37092588 PMCID: PMC10288269 DOI: 10.1002/advs.202207455] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 03/10/2023] [Indexed: 05/03/2023]
Abstract
Recent global events such as COVID-19 pandemic amid rising rates of chronic lung diseases highlight the need for safer, simpler, and more available treatments for respiratory failure, with increasing interest in extracorporeal membrane oxygenation (ECMO). A key factor limiting use of this technology is the complexity of the blood circuit, resulting in clotting and bleeding and necessitating treatment in specialized care centers. Microfluidic oxygenators represent a promising potential solution, but have not reached the scale or performance required for comparison with conventional hollow fiber membrane oxygenators (HFMOs). Here the development and demonstration of the first microfluidic respiratory assist device at a clinical scale is reported, demonstrating efficient oxygen transfer at blood flow rates of 750 mL min⁻1 , the highest ever reported for a microfluidic device. The central innovation of this technology is a fully 3D branching network of blood channels mimicking key features of the physiological microcirculation by avoiding anomalous blood flows that lead to thrombus formation and blood damage in conventional oxygenators. Low, stable blood pressure drop, low hemolysis, and consistent oxygen transfer, in 24-hour pilot large animal experiments are demonstrated - a key step toward translation of this technology to the clinic for treatment of a range of lung diseases.
Collapse
Affiliation(s)
| | | | - Jose Santos
- Bioengineering DivisionDraperCambridgeMA02139USA
| | | | - Teryn R. Roberts
- Autonomous Reanimation and Evacuation (AREVA) Research ProgramThe Geneva FoundationSan AntonioTX78234USA
| | - George Harea
- Autonomous Reanimation and Evacuation (AREVA) Research ProgramThe Geneva FoundationSan AntonioTX78234USA
| | | | - Beau Landis
- Bioengineering DivisionDraperCambridgeMA02139USA
| | | | - Joseph Urban
- Bioengineering DivisionDraperCambridgeMA02139USA
| | - Daniel Lang
- Bioengineering DivisionDraperCambridgeMA02139USA
| | - Bryan Teece
- Bioengineering DivisionDraperCambridgeMA02139USA
| | - WeiXuan Lai
- Bioengineering DivisionDraperCambridgeMA02139USA
| | - Rose Keating
- Bioengineering DivisionDraperCambridgeMA02139USA
| | - Diana Chiang
- Bioengineering DivisionDraperCambridgeMA02139USA
| | - Andriy I. Batchinsky
- Autonomous Reanimation and Evacuation (AREVA) Research ProgramThe Geneva FoundationSan AntonioTX78234USA
| | | |
Collapse
|
2
|
Astor TL, Borenstein JT. The microfluidic artificial lung: Mimicking nature's blood path design to solve the biocompatibility paradox. Artif Organs 2022; 46:1227-1239. [PMID: 35514275 DOI: 10.1111/aor.14266] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2022] [Revised: 04/03/2022] [Accepted: 04/04/2022] [Indexed: 11/28/2022]
Abstract
The increasing prevalence of chronic lung disease worldwide, combined with the emergence of multiple pandemics arising from respiratory viruses over the past century, highlights the need for safer and efficacious means for providing artificial lung support. Mechanical ventilation is currently used for the vast majority of patients suffering from acute and chronic lung failure, but risks further injury or infection to the patient's already compromised lung function. Extracorporeal membrane oxygenation (ECMO) has emerged as a means of providing direct gas exchange with the blood, but limited access to the technology and the complexity of the blood circuit have prevented the broader expansion of its use. A promising avenue toward simplifying and minimizing complications arising from the blood circuit, microfluidics-based artificial organ support, has emerged over the past decade as an opportunity to overcome many of the fundamental limitations of the current standard for ECMO cartridges, hollow fiber membrane oxygenators. The power of microfluidics technology for this application stems from its ability to recapitulate key aspects of physiological microcirculation, including the small dimensions of blood vessel structures and gas transfer membranes. An even greater advantage of microfluidics, the ability to configure blood flow patterns that mimic the smooth, branching nature of vascular networks, holds the potential to reduce the incidence of clotting and bleeding and to minimize reliance on anticoagulants. Here, we summarize recent progress and address future directions and goals for this potentially transformative approach to artificial lung support.
Collapse
Affiliation(s)
- Todd L Astor
- Biomembretics, Inc., Boston, Massachusetts, USA.,Department of Medicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | | |
Collapse
|
3
|
Hesselmann F, Halwes M, Bongartz P, Wessling M, Cornelissen C, Schmitz-Rode T, Steinseifer U, Jansen SV, Arens J. TPMS-based membrane lung with locally-modified permeabilities for optimal flow distribution. Sci Rep 2022; 12:7160. [PMID: 35504939 PMCID: PMC9065140 DOI: 10.1038/s41598-022-11175-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Accepted: 04/11/2022] [Indexed: 11/09/2022] Open
Abstract
Membrane lungs consist of thousands of hollow fiber membranes packed together as a bundle. The devices often suffer from complications because of non-uniform flow through the membrane bundle, including regions of both excessively high flow and stagnant flow. Here, we present a proof-of-concept design for a membrane lung containing a membrane module based on triply periodic minimal surfaces (TPMS). By warping the original TPMS geometries, the local permeability within any region of the module could be raised or lowered, allowing for the tailoring of the blood flow distribution through the device. By creating an iterative optimization scheme for determining the distribution of streamwise permeability inside a computational porous domain, the desired form of a lattice of TPMS elements was determined via simulation. This desired form was translated into a computer-aided design (CAD) model for a prototype device. The device was then produced via additive manufacturing in order to test the novel design against an industry-standard predicate device. Flow distribution was verifiably homogenized and residence time reduced, promising a more efficient performance and increased resistance to thrombosis. This work shows the promising extent to which TPMS can serve as a new building block for exchange processes in medical devices.
Collapse
Affiliation(s)
- Felix Hesselmann
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany.
| | - Michael Halwes
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany
| | - Patrick Bongartz
- Chair of Chemical Process Engineering, RWTH Aachen University, Forckenbeckstr. 51, 52074, Aachen, Germany
| | - Matthias Wessling
- Chair of Chemical Process Engineering, RWTH Aachen University, Forckenbeckstr. 51, 52074, Aachen, Germany.,DWI-Leibniz Institute for Interactive Materials, RWTH Aachen University, Forckenbeckstr. 50, 52074, Aachen, Germany
| | - Christian Cornelissen
- Department of Pneumology and Internal Intensive Care Medicine, Medical Clinic V, RWTH Aachen University Hospital, Pauwelsstr. 30, 52074, Aachen, Germany
| | - Thomas Schmitz-Rode
- Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany
| | - Sebastian Victor Jansen
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany.,Chair of Engineering Organ Support Technologies, Department of Biomechanical Engineering, Faculty of Engineering, Technology University of Twente, Enschede, The Netherlands
| |
Collapse
|
4
|
Gerritse M, van Hoeven M, Overdevest E. Comparison of venous pCO 2 and exhaust pCO 2 for calculating CO 2 production during cardiopulmonary bypass. Perfusion 2022; 38:801-806. [PMID: 35393901 DOI: 10.1177/02676591221083790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
INTRODUCTION Carbon dioxide production (VCO2i), oxygen consumption and oxygen delivery can be monitored during cardiopulmonary bypass (CPB) as markers for tissue perfusion. This study examines if inline venous pCO2 (PvCO2) monitoring can be used as an alternative to exhaust gas pCO2 (ExCO2) to calculate VCO2i. METHODS PvCO2 and ExCO2 were monitored continuously during 40 elective coronary artery bypass grafting (CABG) procedures. VCO2i was calculated with ExCO2 as well as PvCO2. RESULTS Mean PvCO2 was 0.27 mmHg higher than mean ExCO2 (p < .001). The 95% limits of agreement of PvCO2 and ExCO2 were [-2.99, 3.53] mmHg which is within the limits proposed by the Clinical Laboratory Improvement Amendments of 2019. VCO2i was calculated using both PvCO2 and ExCO2 (PvVCO2i; ExVCO2i). A strong linear correlation was found for ExVCO2i and PvVCO2i (R2= .94, p < .001). CONCLUSION In conclusion, the differences in VCO2i calculation between the two methods are unlikely to be clinically relevant during normothermic CABG procedures. VCO2i can be calculated with either a capnograph or inline venous pCO2 monitoring.
Collapse
Affiliation(s)
- Matthijs Gerritse
- Department of Extracorporeal Circulation, 3168Catharina Hospital, Eindhoven, The Netherlands
| | - Marloes van Hoeven
- Department of Extracorporeal Circulation, 3168Catharina Hospital, Eindhoven, The Netherlands
| | - Eddy Overdevest
- Department of Extracorporeal Circulation, 3168Catharina Hospital, Eindhoven, The Netherlands
| |
Collapse
|
5
|
Hendrix RHJ, Debeuckelaere G, Degezelle K, Lenaerts L, Verbelen T, Weerwind PW. Clinical evaluation of the novel Capiox NX19 adult oxygenator-a multicenter study. Perfusion 2022; 38:734-739. [PMID: 35348392 PMCID: PMC10102914 DOI: 10.1177/02676591221078942] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
INTRODUCTION The novel Capiox NX19 adult oxygenator is, compared to its predecessors, improved with enhanced air removal technology, a polymer heat exchanger and smaller, innovative hollow fibers resulting in a surface area reduction and a lower priming volume. The aim of this study was to evaluate the NX19 oxygenator performance in a clinical setting. METHODS A prospective multicenter study was performed involving three large European university hospitals. The Capiox NX19 (n = 150) performance was assessed during adult cardiopulmonary bypass and involved gaseous microemboli handling and gas transfer efficiency. The heat exchanger performance was evaluated separately in vitro. RESULTS The heat exchanger performance factors were 0.80 ± 0.03 and 0.58 ± 0.04 at pump flow rates of 3 L/min and 6 L/min, respectively. After priming, residual post-oxygenator gaseous microemboli count and volume were decreased by 91% and 93.7%, respectively. The gas compartment pressure was 6.0 ± 2.5 mmHg, while the O2 transfer was 69 ± 30 mL/min/m2 and the CO2 transfer 73 ± 34 mL/min/m2. The O2 gradient was 44 ± 19 mmHg/LPM and the O2 diffusing capacity 0.38 ± 0.14 mL/min/mmHg. The shunt fraction was 0.19 ± 0.13, whereas oxygenator resistance and shear stress were 10.5 ± 3.7 mmHg/LPM and 5.1 ± 3.1 dyn/cm2, respectively. CONCLUSION This multicenter study displayed good clinical safety and performance of the NX19 oxygenator.
Collapse
Affiliation(s)
- Rik H J Hendrix
- Department of Cardiothoraxic Surgery, 199236Maastricht University Medical Centre, Maastricht, Netherlands
| | - Gerdy Debeuckelaere
- Department of Extra-corporeal Circulation, 60202University Hospital Antwerp, Edegem, Belgium
| | - Karlien Degezelle
- Department of Perfusion Technology, 60182University Hospitals Leuven, Leuven, Belgium
| | - Lieven Lenaerts
- Department of Perfusion Technology, 60182University Hospitals Leuven, Leuven, Belgium
| | - Tom Verbelen
- Department of Cardiac Surgery, 60182University Hospitals Leuven, Leuven, Belgium
| | - Patrick W Weerwind
- Department of Cardiothoraxic Surgery, 199236Maastricht University Medical Centre, Maastricht, Netherlands
| |
Collapse
|
6
|
Santos JA, Gimbel AA, Peppas A, Truslow JG, Lang DA, Sukavaneshvar S, Solt D, Mulhern TJ, Markoski A, Kim ES, Hsiao JCM, Lewis DJ, Harjes DI, DiBiasio C, Charest JL, Borenstein JT. Design and construction of three-dimensional physiologically-based vascular branching networks for respiratory assist devices. LAB ON A CHIP 2021; 21:4637-4651. [PMID: 34730597 DOI: 10.1039/d1lc00287b] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Microfluidic lab-on-a-chip devices are changing the way that in vitro diagnostics and drug development are conducted, based on the increased precision, miniaturization and efficiency of these systems relative to prior methods. However, the full potential of microfluidics as a platform for therapeutic medical devices such as extracorporeal organ support has not been realized, in part due to limitations in the ability to scale current designs and fabrication techniques toward clinically relevant rates of blood flow. Here we report on a method for designing and fabricating microfluidic devices supporting blood flow rates per layer greater than 10 mL min-1 for respiratory support applications, leveraging advances in precision machining to generate fully three-dimensional physiologically-based branching microchannel networks. The ability of precision machining to create molds with rounded features and smoothly varying channel widths and depths distinguishes the geometry of the microchannel networks described here from all previous reports of microfluidic respiratory assist devices, regarding the ability to mimic vascular blood flow patterns. These devices have been assembled and tested in the laboratory using whole bovine or porcine blood, and in a porcine model to demonstrate efficient gas transfer, blood flow and pressure stability over periods of several hours. This new approach to fabricating and scaling microfluidic devices has the potential to address wide applications in critical care for end-stage organ failure and acute illnesses stemming from respiratory viral infections, traumatic injuries and sepsis.
Collapse
Affiliation(s)
- Jose A Santos
- Bioengineering Division, Draper, Cambridge, MA, USA.
| | - Alla A Gimbel
- Bioengineering Division, Draper, Cambridge, MA, USA.
| | | | | | - Daniel A Lang
- Bioengineering Division, Draper, Cambridge, MA, USA.
| | | | | | | | - Alex Markoski
- Bioengineering Division, Draper, Cambridge, MA, USA.
| | - Ernest S Kim
- Bioengineering Division, Draper, Cambridge, MA, USA.
| | | | - Diana J Lewis
- Bioengineering Division, Draper, Cambridge, MA, USA.
| | | | | | | | | |
Collapse
|
7
|
Gimbel AA, Hsiao JC, Kim ES, Lewis DJ, Risoleo TF, Urban JN, Borenstein JT. A high gas transfer efficiency microfluidic oxygenator for extracorporeal respiratory assist applications in critical care medicine. Artif Organs 2021; 45:E247-E264. [PMID: 33561881 DOI: 10.1111/aor.13935] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 01/10/2021] [Accepted: 02/05/2021] [Indexed: 12/15/2022]
Abstract
Advances in microfluidics technologies have spurred the development of a new generation of microfluidic respiratory assist devices, constructed using microfabrication techniques capable of producing microchannel dimensions similar to those found in human capillaries and gas transfer films in the same thickness range as the alveolar membrane. These devices have been tested in laboratory settings and in some cases in extracorporeal animal experiments, yet none have been advanced to human clinical studies. A major challenge in the development of microfluidic oxygenators is the difficulty in scaling the technology toward high blood flows necessary to support adult humans; such scaling efforts are often limited by the complexity of the fabrication process and the manner in which blood is distributed in a three-dimensional network of microchannels. Conceptually, a central advantage of microfluidic oxygenators over existing hollow-fiber membrane-based configurations is the potential for shallower channels and thinner gas transfer membranes, features that reduce oxygen diffusion distances, to result in a higher gas transfer efficiency defined as the ratio of the volume of oxygen transferred to the blood per unit time to the active surface area of the gas transfer membrane. If this ratio is not significantly higher than values reported for hollow fiber membrane oxygenators (HFMO), then the expected advantage of the microfluidic approach would not be realized in practice, potentially due to challenges encountered in blood distribution strategies when scaling microfluidic designs to higher flow rates. Here, we report on scaling of a microfluidic oxygenator design from 4 to 92 mL/min blood flow, within an order of magnitude of the flow rate required for neonatal applications. This scaled device is shown to have a gas transfer efficiency higher than any other reported system in the literature, including other microfluidic prototypes and commercial HFMO cartridges. While the high oxygen transfer efficiency is a promising advance toward clinical scaling of a microfluidic architecture, it is accompanied by an excessive blood pressure drop in the circuit, arising from a combination of shallow gas transfer channels and equally shallow distribution manifolds. Therefore, next-generation microfluidic oxygenators will require novel design and fabrication strategies to minimize pressure drops while maintaining very high oxygen transfer efficiencies.
Collapse
Affiliation(s)
| | | | - Ernest S Kim
- Bioengineering Division, Draper, Cambridge, MA, USA
| | | | | | | | | |
Collapse
|
8
|
Wang S, Griffith BP, Wu ZJ. Device-Induced Hemostatic Disorders in Mechanically Assisted Circulation. Clin Appl Thromb Hemost 2021; 27:1076029620982374. [PMID: 33571008 PMCID: PMC7883139 DOI: 10.1177/1076029620982374] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Mechanically assisted circulation (MAC) sustains the blood circulation in the body of a patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) or on ventricular assistance with a ventricular assist device (VAD) or on extracorporeal membrane oxygenation (ECMO) with a pump-oxygenator system. While MAC provides short-term (days to weeks) support and long-term (months to years) for the heart and/or lungs, the blood is inevitably exposed to non-physiological shear stress (NPSS) due to mechanical pumping action and in contact with artificial surfaces. NPSS is well known to cause blood damage and functional alterations of blood cells. In this review, we discussed shear-induced platelet adhesion, platelet aggregation, platelet receptor shedding, and platelet apoptosis, shear-induced acquired von Willebrand syndrome (AVWS), shear-induced hemolysis and microparticle formation during MAC. These alterations are associated with perioperative bleeding and thrombotic events, morbidity and mortality, and quality of life in MCS patients. Understanding the mechanism of shear-induce hemostatic disorders will help us develop low-shear-stress devices and select more effective treatments for better clinical outcomes.
Collapse
Affiliation(s)
- Shigang Wang
- Department of Surgery, 12264University of Maryland School of Medicine, Baltimore, MD, USA
| | - Bartley P Griffith
- Department of Surgery, 12264University of Maryland School of Medicine, Baltimore, MD, USA
| | - Zhongjun J Wu
- Department of Surgery, 12264University of Maryland School of Medicine, Baltimore, MD, USA.,Fischell Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, MD, USA
| |
Collapse
|
9
|
Swol J, Shigemura N, Ichiba S, Steinseifer U, Anraku M, Lorusso R. Artificial lungs--Where are we going with the lung replacement therapy? Artif Organs 2020; 44:1135-1149. [PMID: 33098217 DOI: 10.1111/aor.13801] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2020] [Revised: 08/03/2020] [Accepted: 08/04/2020] [Indexed: 12/12/2022]
Abstract
Lung transplantation may be a final destination therapy in lung failure, but limited donor organ availability creates a need for alternative management, including artificial lung technology. This invited review discusses ongoing developments and future research pathways for respiratory assist devices and tissue engineering to treat advanced and refractory lung disease. An overview is also given on the aftermath of the coronavirus disease 2019 pandemic and lessons learned as the world comes out of this situation. The first order of business in the future of lung support is solving the problems with existing mechanical devices. Interestingly, challenges identified during the early days of development persist today. These challenges include device-related infection, bleeding, thrombosis, cost, and patient quality of life. The main approaches of the future directions are to repair, restore, replace, or regenerate the lungs. Engineering improvements to hollow fiber membrane gas exchangers are enabling longer term wearable systems and can be used to bridge lung failure patients to transplantation. Progress in the development of microchannel-based devices has provided the concept of biomimetic devices that may even enable intracorporeal implantation. Tissue engineering and cell-based technologies have provided the concept of bioartificial lungs with properties similar to the native organ. Recent progress in artificial lung technologies includes continued advances in both engineering and biology. The final goal is to achieve a truly implantable and durable artificial lung that is applicable to destination therapy.
Collapse
Affiliation(s)
- Justyna Swol
- Department of Respiratory Medicine, Allergology and Sleep Medicine, Intensive Care Medicine, Paracelsus Medical University Nuremberg, General Hospital Nuremberg, Nuremberg, Germany
| | - Norihisa Shigemura
- Division of Cardiovascular Surgery, Temple University Health System Inc., Philadelphia, PA, USA
| | - Shingo Ichiba
- Department of Surgical Intensive Care Medicine, Nippon Medical School Hospital, Bunkyo-ku, Japan
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Aachen, Germany
| | - Masaki Anraku
- Department of Thoracic Surgery, The University of Tokyo Graduate School of Medicine Faculty of Medicine, Bunkyo-ku, Japan
| | - Roberto Lorusso
- Cardio-Thoracic Surgery Department - Heart & Vascular Centre, Maastricht University Medical Hospital, Maastricht, The Netherlands
| |
Collapse
|
10
|
Ki KK, Passmore MR, Chan CHH, Malfertheiner MV, Bouquet M, Cho HJ, Suen JY, Fraser JF. Effect of ex vivo extracorporeal membrane oxygenation flow dynamics on immune response. Perfusion 2020; 34:5-14. [PMID: 30966901 DOI: 10.1177/0267659119830012] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Extracorporeal membrane oxygenation is a life-saving support for heart and/or lung failure patients. Despite technological advancement, abnormal physiology persists and has been associated with subsequent adverse events. These include thrombosis, bleeding, systemic inflammatory response syndrome and infection. However, the underlying mechanisms are yet to be elucidated. We aimed to investigate whether the different flow dynamics of extracorporeal membrane oxygenation would alter immune responses, specifically the overall inflammatory response, leukocyte numbers and activation/adhesion surface antigen expression. METHODS An ex vivo model was used with human whole blood circulating at 37°C for 6 hours at high (4 L/minute) or low (1.5 L/minute) flow dynamics, with serial blood samples taken for analysis. RESULTS During high flow, production of interleukin-1β (p < 0.0001), interleukin-6 (p = 0.0075), tumour necrosis factor-α (p = 0.0013), myeloperoxidase (p < 0.0001) and neutrophil elastase (p < 0.0001) were significantly elevated over time compared to low flow, in particular at 6 hours. While the remaining assessments exhibited minute changes between flow dynamics, a consistent trend of modulation in leukocyte subset numbers and phenotype was observed at 6 hours. CONCLUSION We conclude that prolonged circulation at high flow triggers a prominent pro-inflammatory cytokine response and activates neutrophil granule release, but further research is needed to better characterize the effect of flow during extracorporeal membrane oxygenation.
Collapse
Affiliation(s)
- Katrina K Ki
- 1 Critical Care Research Group, Faculty of Medicine, University of Queensland and The Prince Charles Hospital, Brisbane, QLD, Australia
| | - Margaret R Passmore
- 1 Critical Care Research Group, Faculty of Medicine, University of Queensland and The Prince Charles Hospital, Brisbane, QLD, Australia
| | - Chris Hoi Houng Chan
- 2 Critical Care Research Group, Innovative Cardiovascular Engineering and Technology Laboratory, The Prince Charles Hospital, Brisbane, QLD, Australia.,3 School of Engineering and Built Environment, Griffith University, Brisbane, QLD, Australia
| | - Maximillian V Malfertheiner
- 4 Department of Internal Medicine II, Cardiology and Pneumology, University Medical Center Regensburg, Regensburg, Germany
| | - Mahe Bouquet
- 1 Critical Care Research Group, Faculty of Medicine, University of Queensland and The Prince Charles Hospital, Brisbane, QLD, Australia
| | - Hwa Jin Cho
- 5 Department of Pediatrics, Chonnam National University Children's Hospital and Medical School, Gwangju, South Korea
| | - Jacky Y Suen
- 1 Critical Care Research Group, Faculty of Medicine, University of Queensland and The Prince Charles Hospital, Brisbane, QLD, Australia
| | - John F Fraser
- 1 Critical Care Research Group, Faculty of Medicine, University of Queensland and The Prince Charles Hospital, Brisbane, QLD, Australia.,2 Critical Care Research Group, Innovative Cardiovascular Engineering and Technology Laboratory, The Prince Charles Hospital, Brisbane, QLD, Australia
| |
Collapse
|
11
|
Hendrix RH, Yeung AK, Ganushchak YM, Weerwind PW. The effect of flow and pressure on the intraoxygenator flow path of different contemporary oxygenators: an in vitro trial. Perfusion 2020; 35:658-663. [PMID: 32056504 PMCID: PMC7536508 DOI: 10.1177/0267659119899883] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022]
Abstract
Introduction: This study analyzed the effect of different flows and pressures on the
intraoxygenator flow path in three contemporary oxygenators and its
consequences for oxygen transfer efficiency. Methods: In an experimental setup, intraoxygenator flow path parameters were analyzed
at post-oxygenator pressures of 150, 200, and 250 mm Hg and at flows ranging
from 2 L/min to the oxygenators’ maximum permitted flow, with and without
pulsatility. The oxygen gradient and the oxygen transfer per minute and per
100 mL blood were calculated using previously collected clinical data and
compared with the flow path parameters. Results: Increasing pressure did not affect the flow path parameters, whereas
pulsatile flow led to significantly increased dynamic oxygenator blood
volumes. Increased flow resulted in decreased values of the flow path
parameters in all oxygenators, indicating increased flow through short
pathways in the oxygenator. In parallel, oxygen transfer/100 mL blood
decreased in all oxygenators (average 2.5 ± 0.4 to 2.4 ± 0.3 mL/dL,
p > 0.001) and the oxygen gradient increased from 229 ± 45 to
287 ± 29 mm Hg, p > 0.001, indicating decreased oxygen transfer
efficiency. Oxygen transfer/min increased (101 ± 15 to
143 ± 20 mL/min/m2, p > 0.001), however, due to the
increased flow through the oxygenator. Conclusion: Varying trans-membrane oxygenator pressures did not lead to changes in the
intraoxygenator flow path, while an increased flow exhibited lower flow path
parameters resulting in less efficient use of the gas exchange compartment.
The latter was confirmed by a decrease in O2 transfer efficiency
during higher blood flows.
Collapse
Affiliation(s)
- Rik Hj Hendrix
- Department of Extra-Corporeal Circulation, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Alexander Ks Yeung
- Department of Extra-Corporeal Circulation, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Yuri M Ganushchak
- Department of Extra-Corporeal Circulation, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Patrick W Weerwind
- Department of Extra-Corporeal Circulation, Maastricht University Medical Centre, Maastricht, The Netherlands
| |
Collapse
|
12
|
Malchesky PS. Artificial Organs 2018: A Year in Review. Artif Organs 2019; 43:288-317. [PMID: 30680758 DOI: 10.1111/aor.13428] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2019] [Accepted: 01/22/2019] [Indexed: 12/24/2022]
Abstract
In this Editor's Review, articles published in 2018 are organized by category and summarized. We provide a brief reflection of the research and progress in artificial organs intended to advance and better human life while providing insight for continued application of these technologies and methods. Artificial Organs continues in the original mission of its founders "to foster communications in the field of artificial organs on an international level." Artificial Organs continues to publish developments and clinical applications of artificial organ technologies in this broad and expanding field of organ Replacement, Recovery, and Regeneration from all over the world. Peer-reviewed special issues this year included contributions from the 13th International Conference on Pediatric Mechanical Circulatory Support Systems and Pediatric Cardiopulmonary Perfusion edited by Dr. Akif Undar, and the 25th Congress of the International Society for Mechanical Circulatory Support edited by Dr. Marvin Slepian. Additionally, many editorials highlighted the worldwide survival differences in hemodialysis and perspectives on mechanical circulatory support and stem cell therapies for cardiac support. We take this time also to express our gratitude to our authors for offering their work to this journal. We offer our very special thanks to our reviewers who give so generously of time and expertise to review, critique, and especially provide meaningful suggestions to the author's work whether eventually accepted or rejected. Without these excellent and dedicated reviewers the quality expected from such a journal could not be possible. We also express our special thanks to our Publisher, John Wiley & Sons for their expert attention and support in the production and marketing of Artificial Organs. We look forward to reporting further advances in the coming years.
Collapse
|
13
|
Artificial Lungs for Lung Failure. J Am Coll Cardiol 2018; 72:1640-1652. [DOI: 10.1016/j.jacc.2018.07.049] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/18/2018] [Revised: 06/13/2018] [Accepted: 07/03/2018] [Indexed: 12/20/2022]
|