1
|
Rose V, Haram NH, Gallala S. A new portable negative pressure wound therapy device: a prospective study investigating clinical outcomes. J Wound Care 2024; 33:833-840. [PMID: 39480726 DOI: 10.12968/jowc.2024.0033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2024]
Abstract
OBJECTIVE Closed surgical incision sites at high risk of complications, and with exudate or leakage, are increasingly being managed with closed incision negative pressure wound therapy (ciNPWT) to reduce tissue stress and increase the force necessary to disrupt the incision. This study was undertaken to investigate the performance and safety of a canister-based, single-use NPWT (suNPWT) system when used on closed surgical incision sites. METHOD The investigation was designed as a prospective, open, non-comparative, multicentre study aimed at confirming the safety and performance attributes of the suNPWT system when applied to low-to-moderately exuding closed surgical incisions. The primary performance measure was the wound remaining closed from baseline to the last follow-up visit on day 14. Secondary performance measures included: wound and periwound condition; wear time of the system; product consumption; adherence to therapy; and patients' pain progress. Details of adverse events were also collected. RESULTS Some 35 patients were recruited. The closed surgical incisions responded well to treatment with the tested suNPWT system. All wounds remained closed throughout the investigation. Consistent with other studies of ciNPWT reporting low infection rates, the current study observed either no or low exudation in 90.4% of wounds at the final visit, together with absence of surgical site infection. Pain severity levels were low, both at dressing change and during delivery of negative pressure. No serious adverse device events were reported. CONCLUSION In this study, the suNPWT system supported the healing of closed surgical incisions with no safety concerns relating to its use.
Collapse
Affiliation(s)
- Victoria Rose
- Guy's and St Thomas' Hospitals NHS Trust, London, UK
| | | | - Sarah Gallala
- Wondkliniek TAV Valerie Hanssens, UZ Brussel, Jette, Belgium
| |
Collapse
|
2
|
Haik J, Ullmann Y, Gur E, Biros E, Kornhaber R, Cleary M, Kruchevsky D, Zissman S, Namir Y, Harats M. Spincare System Demonstrates Safety and Efficacy in Treating Partial-Thickness Burns. J Burn Care Res 2024; 45:969-977. [PMID: 38381556 PMCID: PMC11303125 DOI: 10.1093/jbcr/irae024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Indexed: 02/23/2024]
Abstract
Partial-thickness burns are the most common form of burns, affecting the dermis and possibly resulting in scarring and infection. The Spincare System is a new device that uses electrospinning technology to create a temporary skin-like matrix that can be applied to wounds. This study evaluated the performance, safety, and efficacy of Spincare in treating superficial to partial-thickness burns not considered for surgery. A prospective single-arm, open-label, multicenter study was conducted in 3 adult burn units across Israel. Forty-four patients with superficial to intermediate burns of up to 10% of TBSA were enrolled. Spincare was applied to the wounds, and follow-up visits were performed on days 7, 14, and 21 and months 3 and 6 posttreatment. Thirty-one patients with 36 wounds completed the day 21 visit. The mean wound healing area on day 21 was 97.26 ± 9.41%, and the mean healing time was 12.8 ± 4.3 days. Only one moderate adverse event was observed concerning the treatment, and it is important to acknowledge the potential progression of this hypertrophic scar into a keloid. This study demonstrated that Spincare is a safe and effective device for treating superficial to intermediate partial-thickness burns. Spincare achieved rapid and complete wound healing with a low incidence of adverse events.
Collapse
Affiliation(s)
- Josef Haik
- Department of Plastic and Reconstructive Surgery, Sheba Medical Center, Ramat-Gan, affiliated with the School of Medicine, Tel-Aviv University, Tel-Aviv, 52621, Israel
- Talpiot Leadership Program, Sheba Medical Center, Tel-Hashomer, Israel
- Institute for Health Research, University of Notre Dame, Fremantle, 6160, WA, Australia
| | - Yehuda Ullmann
- Department of Plastic and Reconstructive Surgery, Rambam Health Care Campus, affiliated with the Rappaport Faculty of Medicine, Technion, Haifa, 3109601, Israel
| | - Eyal Gur
- Department of Plastic and Reconstructive Surgery, Sourasky Medical Center, affiliated with the School of Medicine, Tel-Aviv University, Tel-Aviv, 6423906, Israel
| | - Erik Biros
- College of Medicine and Dentistry, James Cook University, Townsville, 4810, Australia
- Townville University Hospital, Townsville,4810, Australia
| | - Rachel Kornhaber
- Department of Plastic and Reconstructive Surgery, Sheba Medical Center, Ramat-Gan, affiliated with the School of Medicine, Tel-Aviv University, Tel-Aviv, 52621, Israel
- School of Nursing, Paramedicine and Healthcare Sciences, Charles Sturt University, Bathurst, NSW, 2795, Australia
| | - Michelle Cleary
- School of Nursing, Midwifery and Social Sciences, CQUniversity, Sydeney, NSW, 2000, Australia
| | - Dani Kruchevsky
- Department of Plastic and Reconstructive Surgery, Rambam Health Care Campus, affiliated with the Rappaport Faculty of Medicine, Technion, Haifa, 3109601, Israel
| | - Sivan Zissman
- Department of Plastic and Reconstructive Surgery, Sourasky Medical Center, affiliated with the School of Medicine, Tel-Aviv University, Tel-Aviv, 6423906, Israel
| | - Yossi Namir
- Department of Plastic and Reconstructive Surgery, Sourasky Medical Center, affiliated with the School of Medicine, Tel-Aviv University, Tel-Aviv, 6423906, Israel
| | - Moti Harats
- Department of Plastic and Reconstructive Surgery, Sheba Medical Center, Ramat-Gan, affiliated with the School of Medicine, Tel-Aviv University, Tel-Aviv, 52621, Israel
- Talpiot Leadership Program, Sheba Medical Center, Tel-Hashomer, Israel
- Institute for Health Research, University of Notre Dame, Fremantle, 6160, WA, Australia
| |
Collapse
|
3
|
Poelchow F, Codde J, Kendell R, Edgar DW, Wood FM. A randomised investigation of film-forming silicone gel in superficial partial thickness face and neck burn patients: Indication of improved early scar pigmentation outcomes. Burns 2024; 50:1605-1613. [PMID: 38614897 DOI: 10.1016/j.burns.2024.03.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 03/18/2024] [Accepted: 03/18/2024] [Indexed: 04/15/2024]
Abstract
INTRODUCTION Burns to the face and neck are a source of considerable distress and a challenge to manage with dressings. Further, these often superficial injuries pose a risk of scarring and altered pigmentation. Silicone gels have emerged as a potential solution to the challenges of conservative management for face and neck burn injuries. The aims of this study were to explore the effect of topical silicone compared to routine treatment of conservatively managed burns to the face and neck. METHODS This single-blind, randomised, controlled trial compared topical silicone film-forming dressing to standard of care for superficial partial thickness burns to the face and neck. Time to healing was the primary outcome and secondary outcomes included: 1) scar assessments (modified Vancouver Scar Scale, Dermalab Combo and Patient and Observer Scar Assessment Scale) at six weeks and three months; and 2) pain intensity scale at wound review appointments. RESULTS Of the 55 participants in the face/neck study, 34 were male and 21 were female. Median age was 36 years (range from 25 to 47 years). The median time to healing for the silicone group was 9 days (CI 7.6 -10.4) and the control group was 7 days (CI 5.3- 8.7), p = 0.056. Analysis demonstrated significantly reduced pigmentation at six weeks in mVSS scores for the silicone group (Md = 0, IQR = 0) compared to the control group (Md = 0, IQR = 0 - 3), p = 0.043. We found no evidence of differences in reported pain between the groups (Silicone - Md = 1.15, IQR 0.3 - 4.5 vs control group - Md = 1.5, IQR 0.6 - 3.8, z = -0.63, p = 0.53). No other differences were observed, and no adverse events were associated with the topical silicone in the study whereas an infection and a reaction were experienced in the control group. CONCLUSION Film-forming silicone gel had comparable effects to standard of care emollient on wound healing of superficial partial thickness burns of the face and neck. Silicone treated wounds were associated with a significant improvement in scar pigmentation outcome at six weeks post-burn.
Collapse
Affiliation(s)
- Fiona Poelchow
- State Adult Burn Unit, Fiona Stanley Hospital, Murdoch, Western Australia, Australia; The Institute for Health Research, The University of Notre Dame Australia, Fremantle, Western Australia, Australia; School of Physiotherapy, The University of Notre Dame Australia, Fremantle, Western Australia, Australia
| | - Jim Codde
- The Institute for Health Research, The University of Notre Dame Australia, Fremantle, Western Australia, Australia
| | - Rosemary Kendell
- State Adult Burn Unit, Fiona Stanley Hospital, Murdoch, Western Australia, Australia
| | - Dale W Edgar
- State Adult Burn Unit, Fiona Stanley Hospital, Murdoch, Western Australia, Australia; The Institute for Health Research, The University of Notre Dame Australia, Fremantle, Western Australia, Australia; Fiona Wood Foundation, Perth, Western Australia, Australia; Armadale Kalamunda Group Health Service, Safety and Quality Unit, East Metropolitan Health Service, Mt Nasura, Western Australia, Australia; Burn Injury Research Unit, Faculty of Health and Medical Sciences, University of Western Australia, Crawley, Western Australia, Australia
| | - Fiona M Wood
- State Adult Burn Unit, Fiona Stanley Hospital, Murdoch, Western Australia, Australia; Fiona Wood Foundation, Perth, Western Australia, Australia; Burn Injury Research Unit, Faculty of Health and Medical Sciences, University of Western Australia, Crawley, Western Australia, Australia.
| |
Collapse
|
4
|
Barrett S, Rippon MG, Rogers AA. Effectiveness of wound contact layers in enabling undisturbed wound management: a case series. J Wound Care 2023; 32:134-144. [PMID: 36930187 DOI: 10.12968/jowc.2023.32.3.134] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/18/2023]
Abstract
OBJECTIVE Wound contact layers (WCLs) are intended to protect and support wounds during the healing process. An open, non comparative, case series clinical evaluation was undertaken to assess the impact of these dressings on establishing an undisturbed wound environment that supports effective wound management, and to allow the establishment of limits of duration of the wear time for the experimental WCLs. METHOD The primary objectives of this clinical evaluation were to assess the ability of the WCLs to prevent tissue disturbance to the wound and surrounding skin and for the clinicians to have confidence to extend the wear time of the WCL dressings. For them to have confidence in leaving the dressings in place for extended periods, the assessment of the wound and periwound skin condition and an assessment of patient comfort was performed: assessment of wound and periwound condition in relation to tissue adherence of the dressing to the wound resulting in tissue damage/bleeding (to wound and/or periwound skin) and cellular infiltration into the WCL; assessment of patient wearing comfort and satisfaction; assessment of WCL wear time, relating to times between dressing changes as judged by the clinician. RESULTS Based upon five parameters used to assess the extent to which the WCLs Atrauman, Atrauman Silicone and Atrauman Ag (HARTMANN, Germany) disturbed the underlying tissues-bleeding, wound tissue damage, periwound skin damage, tissue ingrowth and dressing adherence-the majority (>95%) of assessments indicated low or no disturbance of tissue. Over the 14 days of study assessment, the mean (±standard deviation) wear time was 7.3±1.2 days for the Atrauman group, 9.9±2.8 days for the Atrauman Silicone group, and 5.8±1.0 days for the Atrauman Ag group. All dressings were well tolerated by patients and rated highly in terms of in-use dressing performance. CONCLUSION The results indicate that Atrauman WCLs are suitable for the management of a variety of wounds as they promote an undisturbed wound environment, including extended wear time.
Collapse
Affiliation(s)
- Simon Barrett
- Humber NHS Foundation Trust, The Grange Hessle, Hull, UK
| | - Mark G Rippon
- Huddersfield University, Huddersfield, UK
- Daneriver Consultancy Ltd, Holmes Chapel, Cheshire, UK
| | | |
Collapse
|
5
|
Tang B, Ling Q, Yang Q, Li M, Shi W, Wu Q. How to survive a periviable birth baby with birth weight of 450g: A case report. Medicine (Baltimore) 2022; 101:e31356. [PMID: 36281089 PMCID: PMC9592289 DOI: 10.1097/md.0000000000031356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
RATIONALE An increasing number of periviable birth newborns (PVBs) have emerged with concurrent growing high-risk pregnancy. To date, postnatal management of PVBs remains one of the most challenging issues and limited studies have been reported. PATIENT CONCERNS A female baby born at 230/7 weeks of gestation with birth weight of 450g. DIAGNOSIS PVB baby, respiratory distress syndrome (RDS), ventilator associated pneumonia (VAP), intraventricular hemorrhage (IVH), metabolic bone disease of prematurity (MBDP), transient hypothyroxinemia of prematurity (THOP), bronchopulmonary dysplasia (BPD) and retinopathy of prematurity (ROP). INTERVENTIONS Individualized treatment and intensive care, including neonatal resuscitation, effective respiratory and circulatory support, venous access and nutrition, prevention and treatment of infection, management of endocrine and metabolic problems, individualized nursing such as developmental supportive care, integrated oral motor interventions, skin care, family-integrated-care, etc were performed according to existing literature. OUTCOMES The baby was discharged home after 138 days of hospitalization with body weight of 2700 g, a full oral feed achieved, and without any requirement of respiratory support or oxygen supply. Now she is 38-month-old, with no significant long-term adverse sequelae. LESSONS Our case expands the experience and knowledges of individualized and intensive management of PVB babies in their early life days, which increase PVBs' survival and improves their prognosis.
Collapse
Affiliation(s)
- Binzhi Tang
- Department of Pediatrics, Sichuan Academy of Medical Sciences & Sichuan Provincial People’s Hospital, Chengdu, China
- Department of Pediatrics, Clinical College of University of Electronic Science and Technology of China, Chengdu, Sichuan Province, China
| | - Qiying Ling
- Department of Pediatrics, Sichuan Academy of Medical Sciences & Sichuan Provincial People’s Hospital, Chengdu, China
- Department of Pediatrics, Clinical College of University of Electronic Science and Technology of China, Chengdu, Sichuan Province, China
| | - Qian Yang
- Department of Pediatrics, Sichuan Academy of Medical Sciences & Sichuan Provincial People’s Hospital, Chengdu, China
- Department of Pediatrics, Clinical College of University of Electronic Science and Technology of China, Chengdu, Sichuan Province, China
| | - Maojun Li
- Department of Pediatrics, Sichuan Academy of Medical Sciences & Sichuan Provincial People’s Hospital, Chengdu, China
- Department of Pediatrics, Clinical College of University of Electronic Science and Technology of China, Chengdu, Sichuan Province, China
| | - Wei Shi
- Department of Pediatrics, Sichuan Academy of Medical Sciences & Sichuan Provincial People’s Hospital, Chengdu, China
- Department of Pediatrics, Clinical College of University of Electronic Science and Technology of China, Chengdu, Sichuan Province, China
| | - Qing Wu
- Department of Pediatrics, Sichuan Academy of Medical Sciences & Sichuan Provincial People’s Hospital, Chengdu, China
- Department of Pediatrics, Clinical College of University of Electronic Science and Technology of China, Chengdu, Sichuan Province, China
- *Correspondence: Qing Wu, Department of Pediatrics, Sichuan Academy of Medical Sciences & Sichuan Provincial People’s Hospital, No. 32 West Second Section First Ring Road, Chengdu 610072, Sichuan Province, China (e-mail: )
| |
Collapse
|
6
|
Abstract
Wound dressing adherence is an important problem that is frequently encountered in wound care, and is associated with both clinical and economic burdens. However, only a few review articles have focused on this issue. The objective of this review was to present a comprehensive discussion of wound dressing adherence, including the mechanism of dressing adherence, adverse consequences (clinical burdens and economic burdens), factors affecting adherence (dressing-, patient- and wound-related factors, and factors related to the wound care procedure), tests to assess dressing adherence (in vitro assay, in vivo assay and clinical trials), and reduction of wound adherence (modification of dressing adherence and special care in particular patients). Accordingly, this review article emphasises an awareness of dressing adherence, and is intended to be an informative source for the development of new dressings and for wound management.
Collapse
Affiliation(s)
- Apirujee Punjataewakupt
- Department of Pharmacy Practice, Faculty of Pharmaceutical Sciences and Center of Excellence in Bioactive Resources for Innovative Clinical Applications, Chulalongkorn University, Bangkok, Thailand
| | - Pornanong Aramwit
- Department of Pharmacy Practice, Faculty of Pharmaceutical Sciences and Center of Excellence in Bioactive Resources for Innovative Clinical Applications, Chulalongkorn University, Bangkok, Thailand.,The Academy of Science, The Royal Society of Thailand, Dusit, Bangkok, Thailand
| |
Collapse
|
7
|
DAĞCI M, ÖZTEKİN D. Yara Bakımında Kullanılan Yara Örtüsü Teknolojileri: Randomize Kontrollü Çalışmaların İncelenmesi. İSTANBUL GELIŞIM ÜNIVERSITESI SAĞLIK BILIMLERI DERGISI 2022. [DOI: 10.38079/igusabder.996192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
|
8
|
LeBlanc K, Woo K. A pragmatic randomised controlled clinical study to evaluate the use of silicone dressings for the treatment of skin tears. Int Wound J 2021; 19:125-134. [PMID: 33960667 PMCID: PMC8684852 DOI: 10.1111/iwj.13604] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Revised: 04/06/2021] [Accepted: 04/08/2021] [Indexed: 12/31/2022] Open
Abstract
One of the most common types of skin breakdown in ageing populations is skin tears. The International Skin Tear Advisory Panel advocates for special attention to be paid to dressing selection related to skin tear management. The panel recommends choosing dressings that will promote the maintenance of moisture balance, suit the local wound environment, protect peri‐wound skin, control or manage exudate and infection, and optimise caregiver time. It is paramount that dressings protect the fragile nature of the skin associated with those who at heightened risk for skin tear development. To compare the effectiveness of soft silicone dressings (a contact layer and/or foam) for the healing of skin tears with local practices that do not include soft silicone dressings. The study was a pragmatic randomised controlled prospective study. One hundred and twenty‐six individuals from two long‐term care facilities in Ontario Canada who presented with skin tears were randomised into the treatment group using either soft silicone dressings (a contact layer and/or foam) or the control group using non‐adhesive dressings. The current study demonstrated that 96.9% (n = 63) of skin tears in the treatment group healed over a 3‐week period compared with 34.4% (n = 21) in the control group. The proportion of wound healing experienced at week 2 was 89.2% (n = 58) in the treatment group compared with 27.9% (n = 17) in the control group. There was a significantly greater reduction in wound surface area relative to baseline in the treatment group (2.9 cm2) compared with the control group (0.6 cm2) (χ2 = 21.792 P < .0001) at week 1. Survival analysis data supported that skin tears healed 50% faster in the treatment group (11 days) compared with the control group (22 days) (χ2 = 59.677 P < .0001). The expected healing trajectory of acute wounds, including skin tears, if proper wound bed preparation is realised and infection is controlled, is 7 to 21 days. Results of this study suggest the use of silicone dressings support wound healing and aid in wound closure within the expected healing trajectory, with faster complete wound closure and mean healing times compared with non‐silicone dressing for the treatment of STs.
Collapse
Affiliation(s)
- Kimberly LeBlanc
- Wound, Ostomy and Continence Institute, Association of Nurses Specialized in Wound Ostomy Continence, Ottawa, Ontario, Canada.,Faculty of Health Sciences, Western University, London, Ontario, Canada
| | - Kevin Woo
- Faculty of Health Sciences, Western University, London, Ontario, Canada.,Faculty of Nursing, Queen's University, Kingston, Ontario, Canada
| |
Collapse
|
9
|
Swift T, Westgate G, Van Onselen J, Lee S. Developments in silicone technology for use in stoma care. BRITISH JOURNAL OF NURSING (MARK ALLEN PUBLISHING) 2021; 30:7-18. [PMID: 34106775 DOI: 10.12968/bjon.2021.30.sup8.7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Soft silicone's flexibility, adhesive capacity and non-toxic, non-odourous and hypoallergenic nature have made it an established material for adhesive and protective therapeutic devices. In wound care, silicone is a component of contact layer dressings for superficial wounds and silicone gel sheeting for reducing the risk of scarring, as well as of barriers for incontinence-associated dermatitis. Regarding stoma accessories, silicone is established in barrier films to prevent contact dermatitis, adhesive removers to prevent skin stripping and filler gels to prevent appliance leaks. Until recently, silicone has not been used in stoma appliances flanges, as its hydrophobic nature has not allowed for moisture management to permit transepidermal water loss and prevent maceration. Traditional hydrocolloid appliances manage moisture by absorbing water, but this can lead to saturation and moisture-associated skin damage (MASD), as well as increased adhesion and resultant skin tears on removal, known as medical adhesive-related skin injury (MARSI). However, novel silicone compounds have been developed with a distinct evaporation-based mechanism of moisture management. This uses colloidal separation to allow the passage of water vapour at a rate equivalent to normal transepidermal water loss. It has been shown to minimise MASD, increase wear time and permit atraumatic removal without the use of adhesive solvents. Trio Healthcare has introduced this technology with a range of silicone-based flange extenders and is working with the University of Bradford Centre for Skin Sciences on prototype silicone-based stoma appliance flanges designed to significantly reduce the incidence of peristomal skin complications, such as MARSI and MASD. It is hoped that this will also increase appliance wear time, reduce costs and improve patient quality of life.
Collapse
Affiliation(s)
- Thomas Swift
- Lecturer in Polymer Chemistry, University of Bradford
| | - Gillian Westgate
- Business Manager, Faculty of Life Sciences, University of Bradford
| | | | | |
Collapse
|
10
|
Swift T, Westgate G, Van Onselen J, Lee S. Developments in silicone technology for use in stoma care. BRITISH JOURNAL OF NURSING (MARK ALLEN PUBLISHING) 2021; 30:S7-S18. [PMID: 37733647 DOI: 10.12968/bjon.2021.30.sup6a.s7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/23/2023]
Abstract
Soft silicone's flexibility, adhesive capacity and non-toxic, non-odourous and hypoallergenic nature have made it an established material for adhesive and protective therapeutic devices. In wound care, silicone is a component of contact layer dressings for superficial wounds and silicone gel sheeting for reducing the risk of scarring, as well as of barriers for incontinence-associated dermatitis. Regarding stoma accessories, silicone is established in barrier films to prevent contact dermatitis, adhesive removers to prevent skin stripping and filler gels to prevent appliance leaks. Until recently, silicone has not been used in stoma appliances flanges, as its hydrophobic nature has not allowed for moisture management to permit transepidermal water loss and prevent maceration. Traditional hydrocolloid appliances manage moisture by absorbing water, but this can lead to saturation and moisture-associated skin damage (MASD), as well as increased adhesion and resultant skin tears on removal, known as medical adhesive-related skin injury (MARSI). However, novel silicone compounds have been developed with a distinct evaporation-based mechanism of moisture management. This uses colloidal separation to allow the passage of water vapour at a rate equivalent to normal transepidermal water loss. It has been shown to minimise MASD, increase wear time and permit atraumatic removal without the use of adhesive solvents. Trio Healthcare has introduced this technology with a range of silicone-based flange extenders and is working with the University of Bradford Centre for Skin Sciences on prototype silicone-based stoma appliance flanges designed to significantly reduce the incidence of peristomal skin complications, such as MARSI and MASD. It is hoped that this will also increase appliance wear time, reduce costs and improve patient quality of life.
Collapse
Affiliation(s)
- Thomas Swift
- Lecturer in Polymer Chemistry, University of Bradford
| | - Gillian Westgate
- Business Manager, Faculty of Life Sciences, University of Bradford
| | | | | |
Collapse
|
11
|
Swift T, Westgate G, Van Onselen J, Lee S. Developments in silicone technology for use in stoma care. ACTA ACUST UNITED AC 2020; 29:S6-S15. [DOI: 10.12968/bjon.2020.29.6.s6] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Soft silicone's flexibility, adhesive capacity and non-toxic, non-odourous and hypoallergenic nature have made it an established material for adhesive and protective therapeutic devices. In wound care, silicone is a component of contact layer dressings for superficial wounds and silicone gel sheeting for reducing the risk of scarring, as well as of barriers for incontinence-associated dermatitis. Regarding stoma accessories, silicone is established in barrier films to prevent contact dermatitis, adhesive removers to prevent skin stripping and filler gels to prevent appliance leaks. Until recently, silicone has not been used in stoma appliances flanges, as its hydrophobic nature has not allowed for moisture management to permit trans-epidermal water loss and prevent maceration. Traditional hydrocolloid appliances manage moisture by absorbing water, but this can lead to saturation and moisture-associated skin damage (MASD), as well as increased adhesion and resultant skin tears on removal, known as medical adhesive-related skin injury (MARSI). However, novel silicone compounds have been developed with a distinct evaporation-based mechanism of moisture management. This uses colloidal separation to allow the passage of water vapour at a rate equivalent to normal trans-epidermal water loss. It has been shown to minimise MASD, increase wear time and permit atraumatic removal without the use of adhesive solvents. Trio Healthcare has introduced this technology with a range of silicone-based flange extenders and is working with the University of Bradford Centre for Skin Sciences on prototype silicone-based stoma appliance flanges designed to significantly reduce the incidence of peristomal skin complications, such as MARSI and MASD. It is hoped that this will also increase appliance wear time, reduce costs and improve patient quality of life.
Collapse
Affiliation(s)
- Thomas Swift
- Lecturer in Polymer Chemistry, University of Bradford
| | - Gillian Westgate
- Business Manager, Faculty of Life Sciences, University of Bradford
| | | | | |
Collapse
|
12
|
Chou PR, Wu SH, Hsieh MC, Huang SH. Retrospective Study on the Clinical Superiority of the Vacuum-Assisted Closure System with a Silicon-based Dressing over the Conventional Tie-over Bolster Technique in Skin Graft Fixation. ACTA ACUST UNITED AC 2019; 55:medicina55120781. [PMID: 31842472 PMCID: PMC6956263 DOI: 10.3390/medicina55120781] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2019] [Revised: 12/10/2019] [Accepted: 12/11/2019] [Indexed: 01/25/2023]
Abstract
Background and Objectives: The tie-over bolster technique has been conventionally used for skin graft fixation; however, long operative times and postoperative pain are the main disadvantages of this method. In this study, we introduce a new method using vacuum-assisted closure (VAC) with a silicon-based dressing as an alternative for skin graft fixation. This retrospective study aimed to evaluate the clinical effect of the VAC plus silicon-based dressing method and the conventional tie-over bolster technique for skin graft fixation in terms of pain, operative time, and skin graft take rate. Materials and Methods: Sixty patients who underwent skin graft surgery performed by a single surgeon from January 2017 to October 2018 were included in this clinical study. They were divided into two groups based on the type of treatment: tie-over bolster technique and vacuum-assisted closure (VAC), or silicon-based dressing groups. The operative times were recorded twice (during suturing or stapling of the graft and during removal of the dressing) in the two groups; similarly, pain was assessed using a numeric rating scale (NRS) after surgery and during dressing removal. Skin graft take rate was evaluated two weeks after dressing removal. Results: Twenty-six patients who met the eligibility criteria were enrolled into the study and assigned to one of the two groups (n = 13 each). No significant differences in age, gender, and graft area were noted between the two groups of patients. The VAC plus silicon-based dressing group demonstrated higher skin graft take rates (p < 0.05), shorter operation times (p < 0.05), and lower levels of pain (postoperative pain and pain during dressing removal) compared with the tie-over bolster technique group (p < 0.05). Conclusions: These findings indicate that VAC with silicon-based dressing can be used for skin graft fixation due to its superior properties when compared with the conventional method, and can improve the quality of life of patients undergoing skin graft fixation.
Collapse
Affiliation(s)
- Ping-Ruey Chou
- School of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung 807, Taiwan;
| | - Sheng-Hua Wu
- Department of Anesthesiology, School of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung 807, Taiwan;
- Department of Anesthesiology, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan
- Department of Anesthesiology, Kaohsiung Municipal Ta-Tung Hospital, Kaohsiung 807, Taiwan
| | - Meng-Chien Hsieh
- Division of Plastic Surgery, Department of Surgery, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan;
| | - Shu-Hung Huang
- Division of Plastic Surgery, Department of Surgery, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan;
- Department of Surgery, School of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung 807, Taiwan
- Regeneration Medicine and Cell Therapy Research Center, Kaohsiung Medical University, Kaohsiung 807, Taiwan
- Correspondence: ; Tel.: +886-7-3121101 (ext. 7676)
| |
Collapse
|
13
|
Garcia-Orue I, Gainza G, Garcia-Garcia P, Gutierrez FB, Aguirre JJ, Hernandez RM, Delgado A, Igartua M. Composite nanofibrous membranes of PLGA/Aloe vera containing lipid nanoparticles for wound dressing applications. Int J Pharm 2019; 556:320-329. [DOI: 10.1016/j.ijpharm.2018.12.010] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Revised: 11/16/2018] [Accepted: 12/04/2018] [Indexed: 12/11/2022]
|
14
|
David F, Wurtz JL, Breton N, Bisch O, Gazeu P, Kerihuel JC, Guibon O. A randomised, controlled, non-inferiority trial comparing the performance of a soft silicone-coated wound contact layer (Mepitel One) with a lipidocolloid wound contact layer (UrgoTul) in the treatment of acute wounds. Int Wound J 2017; 15:159-169. [PMID: 29205809 DOI: 10.1111/iwj.12853] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2017] [Revised: 10/06/2017] [Accepted: 10/11/2017] [Indexed: 11/28/2022] Open
Abstract
Wound contact layer (WCL) dressings are intended to protect tissue during the healing process. A randomised controlled trial was undertaken to compare 2 such dressings. Outpatients with acute wounds were randomly allocated to treatment with either a soft silicone-coated WCL (intervention group, n = 59) or a lipidocolloid-impregnated WCL (control group, n = 62). At the first dressing removal (day 3), 89.8% of patients in the intervention group experienced non-painful dressing removal (defined as a pain rating <30 mm on a 100 mm visual analogue scale), compared with 73.6% of patients in the control group (P = .017) (per protocol population). At day 21, wounds were considered as healed in 66.1% of patients in the intervention group compared with 43.5% in the control group (P = .012) (intention-to-treat population). Both dressings were well tolerated and rated highly in terms of in-use characteristics, although the soft silicone-coated WCL was rated significantly higher than the lipidocolloid-impregnated WCL in terms of its ability to remain in place (P= .016). The results indicate that the soft silicone-coated WCL is suitable for the management of acute wounds as it can minimise dressing-associated pain and support healing.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Odile Guibon
- Medical Affairs Department, Mölnlycke Health Care, Wasquehal, France
| |
Collapse
|