1
|
Schuerger AC. Microbial Protocols for Spacecraft: 1. Effects of Surface Texture, Low Pressure, and UV Irradiation on Recovery of Microorganisms from Surfaces. ASTROBIOLOGY 2022; 22:1061-1071. [PMID: 35675686 DOI: 10.1089/ast.2021.0141] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Modeling risks for the forward contamination of planetary surfaces from endemic bioburdens on landed spacecraft requires precise data on the biocidal effects of space factors on microbial survival. Numerous studies have been published over the preceding 60 years on the survival of diverse microorganisms exposed to solar heating, solar ultraviolet (UV) irradiation, vacuum, ionizing radiation, desiccation, and many other planetary surface conditions. These data were generated with diverse protocols that can impair the interpretations of the results due to dynamic experimental errors inherent in all lab protocols. The current study (1) presents data on how metal surfaces can affect spore adhesion, (2) proposes doping and extraction protocols that can achieve very high recovery rates (close to 100%) from aluminum coupons with four Bacillus spp., (3) establishes a timeline in which dried spores on aluminum coupons should be used to minimize aging effects of spore monolayers, (4) confirms that vacuum alone does not dislodge spores dried on aluminum coupons, and (5) establishes that multiple UV irradiation sources yield similar results if properly cross-calibrated. The protocols are given to advance discussions in the planetary protection community on how to standardize lab protocols to align results from diverse labs into a coherent interpretation of how space conditions will degrade microbial survival over time.
Collapse
Affiliation(s)
- Andrew C Schuerger
- Department of Plant Pathology, University of Florida, Space Life Sciences Lab, Exploration Park, Merritt Island, Florida, USA
| |
Collapse
|
2
|
Jansson L, Akel Y, Eriksson R, Lavander M, Hedman J. Impact of swab material on microbial surface sampling. J Microbiol Methods 2020; 176:106006. [DOI: 10.1016/j.mimet.2020.106006] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 07/16/2020] [Accepted: 07/16/2020] [Indexed: 12/13/2022]
|
3
|
Cicciarella Modica D, Maurici M, D’Alò GL, Mozzetti C, Messina A, Distefano A, Pica F, De Filippis P. Taking Screenshots of the Invisible: A Study on Bacterial Contamination of Mobile Phones from University Students of Healthcare Professions in Rome, Italy. Microorganisms 2020; 8:microorganisms8071075. [PMID: 32707676 PMCID: PMC7409191 DOI: 10.3390/microorganisms8071075] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2020] [Revised: 07/15/2020] [Accepted: 07/16/2020] [Indexed: 01/07/2023] Open
Abstract
Mobile phones (MPs) are commonly used both in the personal and professional life. We assessed microbiological contamination of MPs from 108 students in healthcare professions (HPs), in relation to their demographic characteristics and MPs handling habits, collected by means of a questionnaire. Cultural and biochemical tests were performed, and statistical analyses were carried out. Staphylococci were present in 85% of MPs, Enterococci in 37%, Coliforms in 6.5%; E. coli was never detected. Staphylococcus epidermidis was the most frequently isolated staphylococcal species (72% of MPs), followed by S. capitis (14%), S. saprophyticus, S. warneri, S. xylosus (6%), and by S. aureus (4%). Heterotrophic Plate Counts (HPC) at 37 °C, ranged from 0 to 1.2 × 104 CFU/dm2 (mean = 362 CFU/dm2). In univariate analysis, the male gender only was significantly associated with higher HPCs and enterococcal contamination. Multiple linear regression models explained only 17% and 16% of the HPC 37 °C and staphylococcal load variability, respectively. Developing specific guidelines for a hygienic use of MPs in clinical settings, for preventing cross-infection risks, is advisable, as well as introducing specific training programs to HP students. MPs decontamination procedures could also be implemented in the community.
Collapse
Affiliation(s)
| | - Massimo Maurici
- Department of Biomedicine and Prevention, University of Rome Tor Vergata, 00133 Rome, Italy; (C.M.); (A.M.); (A.D.); (P.D.F.)
- Correspondence: (M.M.); (G.L.D.); Tel.: +39-327-8218-514 (G.L.D.)
| | - Gian Loreto D’Alò
- Department of Biomedicine and Prevention, University of Rome Tor Vergata, 00133 Rome, Italy; (C.M.); (A.M.); (A.D.); (P.D.F.)
- Department of Epidemiology, Lazio Regional Health Service, 00154 Rome, Italy
- Correspondence: (M.M.); (G.L.D.); Tel.: +39-327-8218-514 (G.L.D.)
| | - Cinzia Mozzetti
- Department of Biomedicine and Prevention, University of Rome Tor Vergata, 00133 Rome, Italy; (C.M.); (A.M.); (A.D.); (P.D.F.)
| | - Alessandra Messina
- Department of Biomedicine and Prevention, University of Rome Tor Vergata, 00133 Rome, Italy; (C.M.); (A.M.); (A.D.); (P.D.F.)
| | - Alessandra Distefano
- Department of Biomedicine and Prevention, University of Rome Tor Vergata, 00133 Rome, Italy; (C.M.); (A.M.); (A.D.); (P.D.F.)
| | - Francesca Pica
- Department of Experimental Medicine, University of Rome Tor Vergata, 00133 Rome, Italy;
| | - Patrizia De Filippis
- Department of Biomedicine and Prevention, University of Rome Tor Vergata, 00133 Rome, Italy; (C.M.); (A.M.); (A.D.); (P.D.F.)
| |
Collapse
|
4
|
Abdel-Hady A, Worth Calfee M, Aslett D, Lee SD, Wyrzykowska-Ceradini B, Robbins Delafield F, May K, Touati A. Alternative fast analysis method for cellulose sponge surface sampling wipes with low concentrations of Bacillus Spores. J Microbiol Methods 2018; 156:5-8. [PMID: 30452937 DOI: 10.1016/j.mimet.2018.11.013] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2018] [Revised: 11/15/2018] [Accepted: 11/15/2018] [Indexed: 11/18/2022]
Abstract
Environmental sampling is a critical component of the post decontamination verification process following a bioterrorism event. The current work was performed to produce a less labor-intensive method for processing cellulose sponge-wipes used for sampling areas potentially contaminated with low concentrations (i.e., post-decontamination) of Bacillus anthracis spores. An alternative fast-analysis processing method was compared to the processing protocol validated by the Centers for Disease Control and Prevention (CDC) for the Laboratory Response Network (LRN). Glazed tile coupons (1102 cm2) were inoculated with 50, 500, or 5000 spores of Bacillus thuringiensis subsp. kurstaki (Btk), then sampled with cellulose sponges. Sampling was limited to a 25- by 25-cm area and performed in the same manner as the CDC sampling method. Samples were then processed using either the alternative "Fast Analysis" method or the "CDC method". Three different analysts repeated the tests at each concentration utilizing each method. Mean recoveries, labor time, and potentially hazardous waste produced were compared for the two methods. The mean percent recoveries and standard errors for the samples processed using the "CDC method" were 39.9 ± 6.7, 43 ± 7.6, and 36.8 ± 10.1 for the 5000, 500, and 50 spore loading levels, respectively; compared to 54.2 ± 12.9, 64.2 ± 21.7, and 45.2 ± 8.6 for the "Fast Analysis" method. At each titer tested the "Fast Analysis" method resulted in a statistically significant higher percent recovery. Furthermore, analysts processed samples utilizing the "Fast Analysis" method in less than half the time and generated half as much potentially hazardous waste compared to the "CDC method".
Collapse
Affiliation(s)
- Ahmed Abdel-Hady
- Jacobs Technology, Inc., 600 William Northern Blvd, Tullahoma, TN 37388, USA
| | - M Worth Calfee
- U.S. EPA, Office of Research and Development, National Homeland Security Research Center, Research Triangle Park, NC, USA.
| | - Denise Aslett
- Jacobs Technology, Inc., 600 William Northern Blvd, Tullahoma, TN 37388, USA
| | - Sang Don Lee
- U.S. EPA, Office of Research and Development, National Homeland Security Research Center, Research Triangle Park, NC, USA
| | | | - F Robbins Delafield
- Jacobs Technology, Inc., 600 William Northern Blvd, Tullahoma, TN 37388, USA
| | - Kathleen May
- Jacobs Technology, Inc., 600 William Northern Blvd, Tullahoma, TN 37388, USA
| | - Abderrahmane Touati
- Jacobs Technology, Inc., 600 William Northern Blvd, Tullahoma, TN 37388, USA
| |
Collapse
|
5
|
Ditommaso S, Giacomuzzi M, Ricciardi E, Zotti C. Experimental Study to Develop a Method for Improving Sample Collection to Monitor Laryngoscopes after Reprocessing. Clin Endosc 2018; 51:463-469. [PMID: 30130841 PMCID: PMC6182295 DOI: 10.5946/ce.2018.012] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2017] [Accepted: 04/10/2018] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND/AIMS The microbiological surveillance of endoscopes and automated flexible endoscope reprocessing have been proven to be two of the most difficult and controversial areas of infection control in endoscopy. The purpose of this study was to standardize a sampling method for assessing the effectiveness of standard reprocessing operating procedures for flexible fiberoptic laryngoscopes (FFLs). METHODS First, the sampling devices were directly inoculated with Bacillus atrophaeus spores; second, tissue non tissue (TNT) wipes were tested on artificially contaminated surfaces and on FFLs. RESULTS Comparison of the sponges, cellulose, and TNT wipes indicated that the TNT wipes were more effective in releasing spores (93%) than the sponges (49%) and cellulose wipes (52%). The developed protocol provides a high efficiency for both collection and extraction from the stainless steel surface (87% of the spores were removed and released) and from the FFL (85% of the spores were removed and released), with relatively low standard deviations for recovery efficiency, particularly for the analysis of the FFL. CONCLUSION TNT wipes are more efficient for sampling surface areas, thereby aiding in the accuracy and reproducibility of environmental surveillance.
Collapse
Affiliation(s)
- Savina Ditommaso
- Department of Public Health and Pediatrics, University of Turin, Turin, Italy
| | - Monica Giacomuzzi
- Department of Public Health and Pediatrics, University of Turin, Turin, Italy
| | - Elisa Ricciardi
- Department of Public Health and Pediatrics, University of Turin, Turin, Italy
| | - Carla Zotti
- Department of Public Health and Pediatrics, University of Turin, Turin, Italy
| |
Collapse
|
6
|
Bruijns BB, Tiggelaar RM, Gardeniers H. The Extraction and Recovery Efficiency of Pure
DNA
for Different Types of Swabs. J Forensic Sci 2018; 63:1492-1499. [DOI: 10.1111/1556-4029.13837] [Citation(s) in RCA: 54] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Revised: 05/01/2018] [Accepted: 05/18/2018] [Indexed: 11/28/2022]
Affiliation(s)
- Brigitte B. Bruijns
- Mesoscale Chemical Systems MESA+ Institute for Nanotechnology University of Twente Drienerlolaan 5 7522 NB Enschede The Netherlands
- Life Science, Engineering & Design Saxion University of Applied Sciences M. H. Tromplaan 28 7513 AB Enschede The Netherlands
| | - Roald M. Tiggelaar
- Mesoscale Chemical Systems MESA+ Institute for Nanotechnology University of Twente Drienerlolaan 5 7522 NB Enschede The Netherlands
- NanoLab Cleanroom MESA+ Institute for Nanotechnology University of Twente Drienerlolaan 5 7522 NB Enschede The Netherlands
| | - Han Gardeniers
- Mesoscale Chemical Systems MESA+ Institute for Nanotechnology University of Twente Drienerlolaan 5 7522 NB Enschede The Netherlands
| |
Collapse
|
7
|
Hutchison JR, Piepel GF, Amidan BG, Hess BM, Sydor MA, Deatherage Kaiser BL. Comparison of false-negative rates and limits of detection following macrofoam-swab sampling of Bacillus anthracis surrogates via Rapid Viability PCR and plate culture. J Appl Microbiol 2018; 124:1092-1106. [PMID: 29356220 DOI: 10.1111/jam.13706] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2017] [Revised: 12/07/2017] [Accepted: 12/18/2017] [Indexed: 12/22/2022]
Abstract
AIMS We evaluated the effects of Bacillus anthracis surrogates, low surface concentrations, surface materials and assay methods on false-negative rate (FNR) and limit of detection (LOD95 ) for recovering Bacillus spores using a macrofoam-swab sampling procedure. METHODS AND RESULTS Bacillus anthracis Sterne or Bacillus atrophaeus Nakamura spores were deposited over a range of low target concentrations (2-500 per coupon) onto glass, stainless steel, vinyl tile and plastic. Samples were assayed using a modified Rapid Viability-PCR (mRV-PCR) method and the traditional plate culture method to obtain FNR and LOD95 results. CONCLUSIONS Mean FNRs tended to be lower for mRV-PCR compared to culturing, and increased as spore concentration decreased for all surface materials. Surface material, but not B. anthracis surrogate, influenced FNRs with the mRV-PCR method. The mRV-PCR LOD95 was lowest for glass and highest for vinyl tile. LOD95 values overall were lower for mRV-PCR than for the culture method. SIGNIFICANCE AND IMPACT OF STUDY This study adds to the limited data on FNR and LOD95 for mRV-PCR and culturing methods with low concentrations of B. anthracis sampled from various surface materials by the CDC macrofoam-swab method. These are key inputs for planning characterization and clearance studies for low contamination levels of B. anthracis.
Collapse
Affiliation(s)
- J R Hutchison
- National Security Directorate, Pacific Northwest National Laboratory, Richland, WA, USA
| | - G F Piepel
- National Security Directorate, Pacific Northwest National Laboratory, Richland, WA, USA
| | - B G Amidan
- National Security Directorate, Pacific Northwest National Laboratory, Richland, WA, USA
| | - B M Hess
- National Security Directorate, Pacific Northwest National Laboratory, Richland, WA, USA
| | - M A Sydor
- National Security Directorate, Pacific Northwest National Laboratory, Richland, WA, USA
| | - B L Deatherage Kaiser
- National Security Directorate, Pacific Northwest National Laboratory, Richland, WA, USA
| |
Collapse
|
8
|
Mott T, Shoe J, Hunter M, Woodson A, Fritts K, Klimko C, Quirk A, Welkos S, Cote C. Comparison of sampling methods to recover germinatedBacillus anthracisandBacillus thuringiensisendospores from surface coupons. J Appl Microbiol 2017; 122:1219-1232. [DOI: 10.1111/jam.13418] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2017] [Revised: 02/03/2017] [Accepted: 02/04/2017] [Indexed: 11/26/2022]
Affiliation(s)
- T.M. Mott
- Bacteriology Division; United States Army Medical Research Institute of Infectious Disease (USAMRIID); Frederick MD USA
| | - J.L. Shoe
- Bacteriology Division; United States Army Medical Research Institute of Infectious Disease (USAMRIID); Frederick MD USA
| | - M. Hunter
- Bacteriology Division; United States Army Medical Research Institute of Infectious Disease (USAMRIID); Frederick MD USA
| | - A.M. Woodson
- Bacteriology Division; United States Army Medical Research Institute of Infectious Disease (USAMRIID); Frederick MD USA
| | - K.A. Fritts
- Bacteriology Division; United States Army Medical Research Institute of Infectious Disease (USAMRIID); Frederick MD USA
| | - C.P. Klimko
- Bacteriology Division; United States Army Medical Research Institute of Infectious Disease (USAMRIID); Frederick MD USA
| | - A.V. Quirk
- Bacteriology Division; United States Army Medical Research Institute of Infectious Disease (USAMRIID); Frederick MD USA
| | - S.L. Welkos
- Bacteriology Division; United States Army Medical Research Institute of Infectious Disease (USAMRIID); Frederick MD USA
| | - C.K. Cote
- Bacteriology Division; United States Army Medical Research Institute of Infectious Disease (USAMRIID); Frederick MD USA
| |
Collapse
|
9
|
Silvestri EE, Yund C, Taft S, Bowling CY, Chappie D, Garrahan K, Brady-Roberts E, Stone H, Nichols TL. Considerations for estimating microbial environmental data concentrations collected from a field setting. JOURNAL OF EXPOSURE SCIENCE & ENVIRONMENTAL EPIDEMIOLOGY 2017; 27:141-151. [PMID: 26883476 PMCID: PMC5318663 DOI: 10.1038/jes.2016.3] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Accepted: 12/07/2015] [Indexed: 06/05/2023]
Abstract
In the event of an indoor release of an environmentally persistent microbial pathogen such as Bacillus anthracis, the potential for human exposure will be considered when remedial decisions are made. Microbial site characterization and clearance sampling data collected in the field might be used to estimate exposure. However, there are many challenges associated with estimating environmental concentrations of B. anthracis or other spore-forming organisms after such an event before being able to estimate exposure. These challenges include: (1) collecting environmental field samples that are adequate for the intended purpose, (2) conducting laboratory analyses and selecting the reporting format needed for the laboratory data, and (3) analyzing and interpreting the data using appropriate statistical techniques. This paper summarizes some key challenges faced in collecting, analyzing, and interpreting microbial field data from a contaminated site. Although the paper was written with considerations for B. anthracis contamination, it may also be applicable to other bacterial agents. It explores the implications and limitations of using field data for determining environmental concentrations both before and after decontamination. Several findings were of interest. First, to date, the only validated surface/sampling device combinations are swabs and sponge-sticks on stainless steel surfaces, thus limiting availability of quantitative analytical results which could be used for statistical analysis. Second, agreement needs to be reached with the analytical laboratory on the definition of the countable range and on reporting of data below the limit of quantitation. Finally, the distribution of the microbial field data and statistical methods needed for a particular data set could vary depending on these data that were collected, and guidance is needed on appropriate statistical software for handling microbial data. Further, research is needed to develop better methods to estimate human exposure from pathogens using environmental data collected from a field setting.
Collapse
Affiliation(s)
- Erin E Silvestri
- United States Environmental Protection Agency, National Homeland Security Research Center, Threat Consequence Assessment Division, Cincinnati, Ohio, USA
| | - Cynthia Yund
- United States Environmental Protection Agency, National Homeland Security Research Center, Threat Consequence Assessment Division, Cincinnati, Ohio, USA
| | - Sarah Taft
- United States Environmental Protection Agency, National Homeland Security Research Center, Threat Consequence Assessment Division, Cincinnati, Ohio, USA
| | - Charlena Yoder Bowling
- United States Environmental Protection Agency, National Homeland Security Research Center, Threat Consequence Assessment Division, Cincinnati, Ohio, USA
| | | | | | - Eletha Brady-Roberts
- United States Environmental Protection Agency, National Homeland Security Research Center, Threat Consequence Assessment Division, Cincinnati, Ohio, USA
| | - Harry Stone
- Battelle Memorial Institute, Columbus, Ohio, USA
| | - Tonya L Nichols
- United States Environmental Protection Agency, National Homeland Security Research Center, Threat Consequence Assessment Division, Washington DC, USA
| |
Collapse
|
10
|
Piepel GF, Deatherage Kaiser BL, Amidan BG, Sydor MA, Barrett CA, Hutchison JR. False-negative rate, limit of detection and recovery efficiency performance of a validated macrofoam-swab sampling method for low surface concentrations of Bacillus anthracis Sterne and Bacillus atrophaeus spores. J Appl Microbiol 2016; 121:149-62. [PMID: 26972788 DOI: 10.1111/jam.13128] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2016] [Revised: 03/04/2016] [Accepted: 03/07/2016] [Indexed: 11/27/2022]
Abstract
AIMS We sought to evaluate the effects of Bacillus species, low surface concentrations, and surface material on recovery efficiency (RE), false-negative rate (FNR) and limit of detection for recovering Bacillus spores using a validated macrofoam-swab sampling procedure. METHODS AND RESULTS The performance of a macrofoam-swab sampling method was evaluated using Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus Nakamura (BG) spores applied at nine low target surface concentrations (2 to 500 CFU per plate or coupon) to positive-control plates and test coupons (25·8064 cm(2) ) of four surface materials (glass, stainless steel, vinyl tile and plastic). The Bacillus species and surface material had statistically significant effects on RE, but surface concentration did not. Mean REs were the lowest for vinyl tile (50·8% with BAS and 40·2% with BG) and the highest for glass (92·8% with BAS and 71·4% with BG). FNR values (which ranged from 0 to 0·833 for BAS and from 0 to 0·806 for BG) increased as surface concentration decreased in the range tested. Surface material also had a statistically significant effect on FNR, with FNR the lowest for glass and highest for vinyl tile. Finally, FNR tended to be higher for BG than for BAS at lower surface concentrations, especially for glass. CONCLUSIONS Concentration and surface material had significant effects on FNR, with Bacillus species having a small effect. Species and surface material had significant effects on RE, with surface concentration having a nonsignificant effect. SIGNIFICANCE AND IMPACT OF THE STUDY The results provide valuable information on the performance of the macrofoam-swab method for low surface concentrations of Bacillus spores, which can be adapted to assess the likelihood that there is no contamination when all macrofoam-swab samples fail to detect B. anthracis.
Collapse
Affiliation(s)
- G F Piepel
- Applied Statistics and Computational Sciences, Pacific Northwest National Laboratory, Richland, WA, USA
| | - B L Deatherage Kaiser
- Chemical and Biological Signature Science Group, Pacific Northwest National Laboratory, Richland, WA, USA
| | - B G Amidan
- Applied Statistics and Computational Sciences, Pacific Northwest National Laboratory, Richland, WA, USA
| | - M A Sydor
- Chemical and Biological Signature Science Group, Pacific Northwest National Laboratory, Richland, WA, USA
| | - C A Barrett
- Analytical Chemistry of Nuclear Materials, Pacific Northwest National Laboratory, Richland, WA, USA
| | - J R Hutchison
- Chemical and Biological Signature Science Group, Pacific Northwest National Laboratory, Richland, WA, USA
| |
Collapse
|
11
|
Hedman J, Knutsson R, Ansell R, Rådström P, Rasmusson B. Pre-PCR processing in bioterrorism preparedness: improved diagnostic capabilities for laboratory response networks. Biosecur Bioterror 2014; 11 Suppl 1:S87-101. [PMID: 23971826 DOI: 10.1089/bsp.2012.0090] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Diagnostic DNA analysis using polymerase chain reaction (PCR) has become a valuable tool for rapid detection of biothreat agents. However, analysis is often challenging because of the limited size, quality, and purity of the biological target. Pre-PCR processing is an integrated concept in which the issues of analytical limit of detection and simplicity for automation are addressed in all steps leading up to PCR amplification--that is, sampling, sample treatment, and the chemical composition of PCR. The sampling method should maximize target uptake and minimize uptake of extraneous substances that could impair the analysis--so-called PCR inhibitors. In sample treatment, there is a trade-off between yield and purity, as extensive purification leads to DNA loss. A cornerstone of pre-PCR processing is to apply DNA polymerase-buffer systems that are tolerant to specific sample impurities, thereby lowering the need for expensive purification steps and maximizing DNA recovery. Improved awareness among Laboratory Response Networks (LRNs) regarding pre-PCR processing is important, as ineffective sample processing leads to increased cost and possibly false-negative or ambiguous results, hindering the decision-making process in a bioterrorism crisis. This article covers the nature and mechanisms of PCR-inhibitory substances relevant for agroterrorism and bioterrorism preparedness, methods for quality control of PCR reactions, and applications of pre-PCR processing to optimize and simplify the analysis of various biothreat agents. Knowledge about pre-PCR processing will improve diagnostic capabilities of LRNs involved in the response to bioterrorism incidents.
Collapse
Affiliation(s)
- Johannes Hedman
- Johannes Hedman, PhD, is employed as a specialist at the Swedish National Laboratory of Forensic Science (SKL) and holds a research position at Applied Microbiology, Lund University. Rickard Knutsson, PhD, is Director of Security Department, National Veterinary Institute (SVA), Uppsala, Sweden . Ricky Ansell, PhD, is employed as forensic advisor and senior reporting officer at the Swedish National Laboratory of Forensic Science (SKL). Birgitta Rasmusson, PhD, is employed as research director at the Swedish National Laboratory of Forensic Science (SKL) and holds a position as adjunct professor at Applied Microbiology, Lund University. Peter Rådström, PhD, is employed as professor Applied Microbiology, Lund University
| | | | | | | | | |
Collapse
|
12
|
Biological Threat Detection in the Air and on the Surface: How to Define the Risk. Arch Immunol Ther Exp (Warsz) 2014; 62:253-61. [DOI: 10.1007/s00005-014-0296-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2014] [Accepted: 05/22/2014] [Indexed: 10/25/2022]
|
13
|
Harnish D, Heimbuch B, McDonald M, Kinney K, Dion M, Stote R, Rastogi V, Smith L, Wallace L, Lumley A, Schreuder-Gibson H, Wander J. Standard method for deposition of dry, aerosolized, silica-coated Bacillus
spores onto inanimate surfaces. J Appl Microbiol 2014; 117:40-9. [DOI: 10.1111/jam.12509] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2013] [Revised: 03/18/2014] [Accepted: 03/19/2014] [Indexed: 11/29/2022]
Affiliation(s)
- D. Harnish
- Engineering Science Division; Applied Research Associates; Panama City FL USA
| | - B.K. Heimbuch
- Engineering Science Division; Applied Research Associates; Panama City FL USA
| | - M. McDonald
- Engineering Science Division; Applied Research Associates; Panama City FL USA
| | - K. Kinney
- Engineering Science Division; Applied Research Associates; Panama City FL USA
| | - M. Dion
- U.S. Army Natick Soldier Research, Development, and Engineering Center; Natick MA USA
| | - R. Stote
- U.S. Army Natick Soldier Research, Development, and Engineering Center; Natick MA USA
| | - V. Rastogi
- Biodefense Branch; Edgewood Chemical Biological Center; Aberdeen Proving Grounds MD USA
| | - L. Smith
- Biodefense Branch; Edgewood Chemical Biological Center; Aberdeen Proving Grounds MD USA
| | - L. Wallace
- Biodefense Branch; Edgewood Chemical Biological Center; Aberdeen Proving Grounds MD USA
| | - A. Lumley
- Engineering Science Division; Applied Research Associates; Panama City FL USA
| | - H. Schreuder-Gibson
- U.S. Army Natick Soldier Research, Development, and Engineering Center; Natick MA USA
| | - J.D. Wander
- Air Force Research Laboratory; Tyndall Air Force Base FL USA
| |
Collapse
|
14
|
High-density, homogeneous endospore monolayer deposition on test surfaces. J Microbiol Methods 2013; 94:245-8. [PMID: 23719028 DOI: 10.1016/j.mimet.2013.05.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2013] [Revised: 04/22/2013] [Accepted: 05/03/2013] [Indexed: 11/21/2022]
Abstract
Bacillus subtilis spores were deposited in high-density single layers on metal, glass, and polymer substrates using vacuum filtration followed by a wetted filter transfer step. Quantitative analysis of spore transfer was performed using culture-based and germinability assays, and spore distributions were observed with electron microscopy.
Collapse
|
15
|
Abstract
PCR is an important and powerful tool in several fields, including clinical diagnostics, food analysis, and forensic analysis. In theory, PCR enables the detection of one single cell or DNA molecule. However, the presence of PCR inhibitors in the sample affects the amplification efficiency of PCR, thus lowering the detection limit, as well as the precision of sequence-specific nucleic acid quantification in real-time PCR. In order to overcome the problems caused by PCR inhibitors, all the steps leading up to DNA amplification must be optimized for the sample type in question. Sampling and sample treatment are key steps, but most of the methods currently in use were developed for conventional diagnostic methods and not for PCR. Therefore, there is a need for fast, simple, and robust sample preparation methods that take advantage of the accuracy of PCR. In addition, the thermostable DNA polymerases and buffer systems used in PCR are affected differently by inhibitors. During recent years, real-time PCR has developed considerably and is now widely used as a diagnostic tool. This technique has greatly improved the degree of automation and reduced the analysis time, but has also introduced a new set of PCR inhibitors, namely those affecting the fluorescence signal. The purpose of this chapter is to view the complexity of PCR inhibition from different angles, presenting both molecular explanations and practical ways of dealing with the problem. Although diagnostic PCR brings together scientists from different diagnostic fields, end-users have not fully exploited the potential of learning from each other. Here, we have collected knowledge from archeological analysis, clinical diagnostics, environmental analysis, food analysis, and forensic analysis. The concept of integrating sampling, sample treatment, and the chemistry of PCR, i.e., pre-PCR processing, will be addressed as a general approach to overcoming real-time PCR inhibition and producing samples optimal for PCR analysis.
Collapse
Affiliation(s)
- Johannes Hedman
- Swedish National Laboratory of Forensic Science, Linköping, Sweden.
| | | |
Collapse
|
16
|
Lee SD, Calfee MW, Mickelsen L, Wolfe S, Griffin J, Clayton M, Griffin-Gatchalian N, Touati A. Evaluation of surface sampling for Bacillus spores using commercially available cleaning robots. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2013; 47:2595-2601. [PMID: 23431954 DOI: 10.1021/es4000356] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Five commercially available domestic cleaning robots were evaluated on their effectiveness for sampling aerosol-deposited Bacillus atrophaeus spores on different indoor material surfaces. The five robots tested include three vacuum types (R1, R2, and R3), one wet wipe (R4), and one wet vacuum (R5). Tests were conducted on two different surface types (carpet and laminate) with 10(6) colony forming units of B. atrophaeus spores deposited per coupon (35.5 cm × 35.5 cm). Spores were deposited on the center surface (30.5 × 30.5 cm) of the coupon's total surface area (71.5 × 71.5 cm), and the surfaces were sampled with an individual robot in an isolation chamber. Chamber air was sampled using a biofilter sampler to determine the potential for resuspension of spores during sampling. Robot test results were compared to currently used surface sampling methods (vacuum sock for carpet and sponge wipe for laminate). The test results showed that the average sampling efficacies for R1, R2, and R3 on carpet were 26, 162, and 92% of vacuum sock sampling efficacy, respectively. On laminate, R1, R2, R3, R4, and R5 average sampling efficacies were 8, 11, 2, 62, and 32% of sponge wipe sampling efficacy, respectively. We conclude that some robotic cleaners were as efficacious as the currently used surface sampling methods for B. atrophaeus spores on these surfaces.
Collapse
Affiliation(s)
- Sang Don Lee
- National Homeland Security Research Center, United States Environmental Protection Agency , Research Triangle Park, North Carolina, USA.
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Calfee MW, Lee SD, Ryan SP. A rapid and repeatable method to deposit bioaerosols on material surfaces. J Microbiol Methods 2013; 92:375-80. [PMID: 23384827 DOI: 10.1016/j.mimet.2013.01.015] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2012] [Revised: 01/14/2013] [Accepted: 01/14/2013] [Indexed: 11/28/2022]
Abstract
A simple method for repeatably inoculating surfaces with a precise quantity of aerosolized spores was developed. Laboratory studies were conducted to evaluate the variability of the method within and between experiments, the spatial distribution of spore deposition, the applicability of the method to complex surface types, and the relationship between material surface roughness and spore recoveries. Surface concentrations, as estimated by recoveries from wetted-wipe sampling, were between 5×10(3) and 1.5×10(4)CFUcm(-2) across the entire area (930cm(2)) inoculated. Between-test variability (Cv) in spore recoveries was 40%, 81%, 66%, and 20% for stainless steel, concrete, wood, and drywall, respectively. Within-test variability was lower, and did not exceed 33%, 47%, 52%, and 20% for these materials. The data demonstrate that this method is repeatable, is effective at depositing spores across a target surface area, and can be used to dose complex materials such as concrete, wood, and drywall. In addition, the data demonstrate that surface sampling recoveries vary by material type, and this variability can partially be explained by the material surface roughness index. This deposition method was developed for use in biological agent detection, sampling, and decontamination studies, however, is potentially beneficial to any scientific discipline that investigates surfaces containing aerosol-borne particles.
Collapse
Affiliation(s)
- M Worth Calfee
- US EPA, Office of Research and Development, National Homeland Security Research Center, Research Triangle Park, NC, USA.
| | | | | |
Collapse
|
18
|
Perry KA, O'Connell HA, Rose LJ, Noble-Wang JA, Arduino MJ. Storage Effects on Sample Integrity of Environmental Surface Sampling Specimens with Bacillus anthracis Spores. ACTA ACUST UNITED AC 2013; 2013:002. [PMID: 27213119 PMCID: PMC4870600 DOI: 10.4172/2167-0331.s1-002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The effect of packaging, shipping temperatures and storage times on recovery of Bacillus anthracis. Sterne spores from swabs was investigated. Macrofoam swabs were pre-moistened, inoculated with Bacillus anthracis spores, and packaged in primary containment or secondary containment before storage at -15°C, 5°C, 21°C, or 35°C for 0-7 days. Swabs were processed according to validated Centers for Disease Control/Laboratory Response Network culture protocols, and the percent recovery relative to a reference sample (T0) was determined for each variable. No differences were observed in recovery between swabs held at -15° and 5°C, (p ≥ 0.23). These two temperatures provided significantly better recovery than swabs held at 21°C or 35°C (all 7 days pooled, p ≤ 0.04). The percent recovery at 5°C was not significantly different if processed on days 1, 2 or 4, but was significantly lower on day 7 (day 2 vs. 7, 5°C, 102, p=0.03). Secondary containment provided significantly better percent recovery than primary containment, regardless of storage time (5°C data, p ≤ 0.008). The integrity of environmental swab samples containing Bacillus anthracis spores shipped in secondary containment was maintained when stored at -15°C or 5°C and processed within 4 days to yield the optimum percent recovery of spores.
Collapse
Affiliation(s)
- K Allison Perry
- Division of Healthcare Quality Promotion, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, GA, USA
| | - Heather A O'Connell
- Division of Healthcare Quality Promotion, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, GA, USA
| | - Laura J Rose
- Division of Healthcare Quality Promotion, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, GA, USA
| | - Judith A Noble-Wang
- Division of Healthcare Quality Promotion, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, GA, USA
| | - Matthew J Arduino
- Division of Healthcare Quality Promotion, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, GA, USA
| |
Collapse
|
19
|
Piepel GF, Amidan BG, Hu R. Laboratory studies on surface sampling of Bacillus anthracis contamination: summary, gaps and recommendations. J Appl Microbiol 2012; 113:1287-304. [PMID: 22747878 DOI: 10.1111/j.1365-2672.2012.05381.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2011] [Revised: 06/11/2012] [Accepted: 06/23/2012] [Indexed: 11/28/2022]
Abstract
This article summarizes previous laboratory studies to characterize the performance of methods for collecting, storing/transporting, processing and analysing samples from surfaces contaminated by Bacillus anthracis or related surrogates. The focus is on plate culture and count estimates of surface contamination for swab, wipe and vacuum samples of porous and nonporous surfaces. Summaries of the previous studies and their results were assessed to identify gaps in information needed as inputs to calculate key parameters critical to risk management in biothreat incidents. One key parameter is the number of samples needed to make characterization or clearance decisions with specified statistical confidence. Other key parameters include the ability to calculate, following contamination incidents, the (i) estimates of B. anthracis contamination, as well as the bias and uncertainties in the estimates and (ii) confidence in characterization and clearance decisions for contaminated or decontaminated buildings. Gaps in knowledge and understanding identified during the summary of the studies are discussed. Additional work is needed to quantify (i) the false-negative rates of surface-sampling methods with lower concentrations on various surfaces and (ii) the effects on performance characteristics of: aerosol vs liquid deposition of spores, using surrogates instead of B. anthracis, real-world vs laboratory conditions and storage and transportation conditions. Recommendations are given for future evaluations of data from existing studies and possible new studies.
Collapse
Affiliation(s)
- G F Piepel
- Pacific Northwest National Laboratory, Richland, WA 99352, USA.
| | | | | |
Collapse
|
20
|
Impact of processing method on recovery of bacteria from wipes used in biological surface sampling. Appl Environ Microbiol 2012; 78:5872-81. [PMID: 22706055 DOI: 10.1128/aem.00873-12] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Environmental sampling for microbiological contaminants is a key component of hygiene monitoring and risk characterization practices utilized across diverse fields of application. However, confidence in surface sampling results, both in the field and in controlled laboratory studies, has been undermined by large variation in sampling performance results. Sources of variation include controlled parameters, such as sampling materials and processing methods, which often differ among studies, as well as random and systematic errors; however, the relative contributions of these factors remain unclear. The objective of this study was to determine the relative impacts of sample processing methods, including extraction solution and physical dissociation method (vortexing and sonication), on recovery of Gram-positive (Bacillus cereus) and Gram-negative (Burkholderia thailandensis and Escherichia coli) bacteria from directly inoculated wipes. This work showed that target organism had the largest impact on extraction efficiency and recovery precision, as measured by traditional colony counts. The physical dissociation method (PDM) had negligible impact, while the effect of the extraction solution was organism dependent. Overall, however, extraction of organisms from wipes using phosphate-buffered saline with 0.04% Tween 80 (PBST) resulted in the highest mean recovery across all three organisms. The results from this study contribute to a better understanding of the factors that influence sampling performance, which is critical to the development of efficient and reliable sampling methodologies relevant to public health and biodefense.
Collapse
|
21
|
Comparison of swab and sponge methodologies for identification of Acinetobacter baumannii from the hospital environment. J Clin Microbiol 2012; 50:2140-1. [PMID: 22461673 DOI: 10.1128/jcm.00448-12] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The ideal sampling method for identification of Acinetobacter baumannii from the health care environment is unknown. In this study, we sampled 145 surfaces in the rooms of patients with known A. baumannii colonization/infection, comparing two methods: swab and sponge. The sensitivity of the swab method was 87%, while the sensitivity of the sponge method was 75%. Given the comparable results, use of the cheaper and less laborious swab technique is acceptable and may be preferable.
Collapse
|
22
|
False-negative rate and recovery efficiency performance of a validated sponge wipe sampling method. Appl Environ Microbiol 2011; 78:846-54. [PMID: 22138998 DOI: 10.1128/aem.07403-11] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Recovery of spores from environmental surfaces varies due to sampling and analysis methods, spore size and characteristics, surface materials, and environmental conditions. Tests were performed to evaluate a new, validated sponge wipe method using Bacillus atrophaeus spores. Testing evaluated the effects of spore concentration and surface material on recovery efficiency (RE), false-negative rate (FNR), limit of detection (LOD), and their uncertainties. Ceramic tile and stainless steel had the highest mean RE values (48.9 and 48.1%, respectively). Faux leather, vinyl tile, and painted wood had mean RE values of 30.3, 25.6, and 25.5, respectively, while plastic had the lowest mean RE (9.8%). Results show roughly linear dependences of RE and FNR on surface roughness, with smoother surfaces resulting in higher mean REs and lower FNRs. REs were not influenced by the low spore concentrations tested (3.10 × 10(-3) to 1.86 CFU/cm(2)). Stainless steel had the lowest mean FNR (0.123), and plastic had the highest mean FNR (0.479). The LOD(90) (≥1 CFU detected 90% of the time) varied with surface material, from 0.015 CFU/cm(2) on stainless steel up to 0.039 on plastic. It may be possible to improve sampling results by considering surface roughness in selecting sampling locations and interpreting spore recovery data. Further, FNR values (calculated as a function of concentration and surface material) can be used presampling to calculate the numbers of samples for statistical sampling plans with desired performance and postsampling to calculate the confidence in characterization and clearance decisions.
Collapse
|
23
|
National validation study of a cellulose sponge wipe-processing method for use after sampling Bacillus anthracis spores from surfaces. Appl Environ Microbiol 2011; 77:8355-9. [PMID: 21965403 DOI: 10.1128/aem.05377-11] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
This work was initiated to address the gaps identified by Congress regarding validated biothreat environmental sampling and processing methods. Nine Laboratory Response Network-affiliated laboratories participated in a validation study of a cellulose sponge wipe-processing protocol for the recovery, detection, and quantification of viable Bacillus anthracis Sterne spores from steel surfaces. Steel coupons (645.16 cm(2)) were inoculated with 1 to 4 log(10) spores and then sampled with cellulose sponges (Sponge-Stick; 3M, St. Paul, MN). Surrogate dust and background organisms were added to the sponges to mimic environmental conditions. Labs processed the sponges according to the provided protocol. Sensitivity, specificity, and mean percent recovery (%R), between-lab variability, within-lab variability, and total percent coefficient of variation were calculated. The mean %R (standard error) of spores from the surface was 32.4 (4.4), 24.4 (2.8), and 30.1 (2.3) for the 1-, 2-, and 4-log(10) inoculum levels, respectively. Sensitivities for colony counts were 84.1%, 100%, and 100% for the 1-, 2-, and 4-log(10) inocula, respectively. These data help to characterize the variability of the processing method and thereby enhance confidence in the interpretation of the results of environmental sampling conducted during a B. anthracis contamination investigation.
Collapse
|
24
|
Da Silva SM, Filliben JJ, Morrow JB. Parameters affecting spore recovery from wipes used in biological surface sampling. Appl Environ Microbiol 2011; 77:2374-80. [PMID: 21296945 PMCID: PMC3067451 DOI: 10.1128/aem.01932-10] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2010] [Accepted: 01/24/2011] [Indexed: 11/20/2022] Open
Abstract
The need for the precise and reliable collection of potential biothreat contaminants has motivated research in developing a better understanding of the variability in biological surface sampling methods. In this context, the objective of this work was to determine parameters affecting the efficiency of extracting Bacillus anthracis Sterne spores from commonly used wipe sampling materials and to describe performance using the interfacial energy concept. In addition, surface thermodynamics was applied to understand and predict surface sampling performance. Wipe materials were directly inoculated with known concentrations of B. anthracis spores and placed into extraction solutions, followed by sonication or vortexing. Experimental factors investigated included wipe material (polyester, cotton, and polyester-rayon), extraction solution (sterile deionized water [H(2)O], deionized water with 0.04% Tween 80 [H(2)O-T], phosphate-buffered saline [PBS], and PBS with 0.04% Tween 80 [PBST]), and physical dissociation method (vortexing or sonication). The most efficient extraction from wipes was observed for solutions containing the nonionic surfactant Tween 80. The increase in extraction efficiency due to surfactant addition was attributed to an attractive interfacial energy between Tween 80 and the centrifuge tube wall, which prevented spore adhesion. Extraction solution significantly impacted the extraction efficiency, as determined by statistical analysis (P < 0.05). Moreover, the extraction solution was the most important factor in extraction performance, followed by the wipe material. Polyester-rayon was the most efficient wipe material for releasing spores into solution by rank; however, no statistically significant difference between polyester-rayon and cotton was observed (P > 0.05). Vortexing provided higher spore recovery in H(2)O and H(2)O-T than sonication, when all three wipe materials and the reference control were considered (P < 0.05).
Collapse
Affiliation(s)
- Sandra M Da Silva
- Biochemical Science Division, Chemical Science Technology Laboratory, National Institute of Standards and Technology, 100 Bureau Dr., Mail Stop 8312, Gaithersburg, MD 20899-8312, USA.
| | | | | |
Collapse
|
25
|
Knutsson R, van Rotterdam B, Fach P, De Medici D, Fricker M, Löfström C, Ågren J, Segerman B, Andersson G, Wielinga P, Fenicia L, Skiby J, Schultz AC, Ehling-Schulz M. Accidental and deliberate microbiological contamination in the feed and food chains — How biotraceability may improve the response to bioterrorism. Int J Food Microbiol 2011; 145 Suppl 1:S123-8. [DOI: 10.1016/j.ijfoodmicro.2010.10.011] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2010] [Revised: 09/27/2010] [Accepted: 10/17/2010] [Indexed: 12/01/2022]
|
26
|
Estill CF, Baron PA, Beard JK, Hein MJ, Larsen LD, Deye GJ, Rose L, Hodges L. Comparison of air sampling methods for aerosolized spores of B. anthracis Sterne. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2011; 8:179-186. [PMID: 21347959 DOI: 10.1080/15459624.2011.556981] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Bacillus anthracis Sterne spores were aerosolized within a chamber at concentrations ranging from 1 x 10³ to 1.7 x 10⁴ spores per cubic meter of air (particles (p)/m³) to compare three different sampling methods: Andersen samplers, gelatin filters, and polytetrafluoroethylene (PTFE) membrane filters. Three samples of each type were collected during each of 19 chamber runs. Chamber concentration was determined by an aerodynamic particle sizer (APS) for the size range of 1.114-1.596 μm. Runs were categorized (low, medium, and high) based on tertiles of the APS estimated air concentrations. Measured air concentrations and recovery efficiency [ratio of the measured (colony forming units (CFU)/m³) to the APS estimated (particles/m³) air concentrations] for the sampling methods were compared using mixed-effects regression models. Limits of detection for each method were estimated based on estimated recovery efficiencies. Mean APS estimated air concentrations were 1600 particles/m³, 4100 particles/m³, and 9100 particles/m³ at the low, medium, and high tertiles, respectively; coefficient of variation (CV) ranged from 25 to 40%. Statistically significant differences were not observed among the three sampling methods. At the high and medium tertiles, estimated correlations of measured air concentration (CFU/m³) among samples collected from the same run of the same type were high (0.73 to 0.93). Among samples collected from the same run but of different types, correlations were moderate to high (0.45 to 0.85); however, correlations were somewhat lower at the low tertile (-0.31 to 0.75). Estimated mean recovery efficiencies ranged from 0.22 to 0.25 CFU/particle with total CVs of approximately 84 to 97%. Estimated detection limits ranged from 35 to 39 particles/m³. These results will enable investigators to conduct environmental sampling, quantify contamination levels, and conduct risk assessments of B. anthracis.
Collapse
Affiliation(s)
- Cheryl Fairfield Estill
- National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinnati, Ohio 45226, USA.
| | | | | | | | | | | | | | | |
Collapse
|
27
|
Recovery of bacillus spore contaminants from rough surfaces: a challenge to space mission cleanliness control. Appl Environ Microbiol 2011; 77:1628-37. [PMID: 21216908 DOI: 10.1128/aem.02037-10] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Microbial contaminants on spacecraft can threaten the scientific integrity of space missions due to probable interference with life detection experiments. Therefore, space agencies measure the cultivable spore load ("bioburden") of a spacecraft. A recent study has reported an insufficient recovery of Bacillus atrophaeus spores from Vectran fabric, a typical spacecraft airbag material (A. Probst, R. Facius, R. Wirth, and C. Moissl-Eichinger, Appl. Environ. Microbiol. 76:5148-5158, 2010). Here, 10 different sampling methods were compared for B. atrophaeus spore recovery from this rough textile, revealing significantly different efficiencies (0.5 to 15.4%). The most efficient method, based on the wipe-rinse technique (foam-spatula protocol; 13.2% efficiency), was then compared to the current European Space Agency (ESA) standard wipe assay in sampling four different kinds of spacecraft-related surfaces. Results indicate that the novel protocol out-performed the standard method with an average efficiency of 41.1% compared to 13.9% for the standard method. Additional experiments were performed by sampling Vectran fabric seeded with seven different spore concentrations and five different Bacillus species (B. atrophaeus, B. anthracis Sterne, B. megaterium, B. thuringiensis, and B. safensis). Among these, B. atrophaeus spores were recovered with the highest (13.2%) efficiency and B. anthracis Sterne spores were recovered with the lowest (0.3%) efficiency. Different inoculation methods of seeding spores on test surfaces (spotting and aerosolization) resulted in different spore recovery efficiencies. The results of this study provide a step forward in understanding the spore distribution on and recovery from rough surfaces. The results presented will contribute relevant knowledge to the fields of astrobiology and B. anthracis research.
Collapse
|
28
|
Development of an aerosol surface inoculation method for bacillus spores. Appl Environ Microbiol 2010; 77:1638-45. [PMID: 21193670 DOI: 10.1128/aem.02237-10] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
A method was developed to deposit Bacillus subtilis spores via aerosolization onto various surface materials for biological agent decontamination and detection studies. This new method uses an apparatus coupled with a metered dose inhaler to reproducibly deposit spores onto various surfaces. A metered dose inhaler was loaded with Bacillus subtilis spores, a surrogate for Bacillus anthracis. Five different material surfaces (aluminum, galvanized steel, wood, carpet, and painted wallboard paper) were tested using this spore deposition method. This aerosolization method deposited spores at a concentration of more than 10(7) CFU per coupon (18-mm diameter) with less than a 50% coefficient of variation, showing that the aerosolization method developed in this study can deposit reproducible numbers of spores onto various surface coupons. Scanning electron microscopy was used to probe the spore deposition patterns on test coupons. The deposition patterns observed following aerosol impaction were compared to those of liquid inoculation. A physical difference in the spore deposition patterns was observed to result from the two different methods. The spore deposition method developed in this study will help prepare spore coupons via aerosolization fast and reproducibly for bench top decontamination and detection studies.
Collapse
|
29
|
Johnson L, Smith ML, Begin M, Fraser B, Miller JD. Remediating office environments of spore-forming bacteria. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2010; 7:585-592. [PMID: 20737349 DOI: 10.1080/15459624.2010.508951] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
This study examines decontamination processes that were developed on an emergency basis to eliminate Bacillus anthracis spores from deliberately contaminated buildings. The recommended steps include a survey with sampling, the removal of sensitive items, and HEPA vacuuming of all readily available surfaces, followed by biocide treatment and subsequent analyses for viable cells. There are several analytical challenges posed by this approach. These include the ability to discriminate the added strain from naturally occurring resident microbes, determining detection limits for anthrax spores in settled dusts, and detecting viable but nonculturable spores. There are also logistical issues relating to the various skill sets required from investigation to reconstruction. In the present study, a model office was constructed, and a strain of Bacillus pumilus was isolated from the carpet and reintroduced to the office in excess. The abundance of the B. pumilus strain was monitored in settled dust using a strain-specific, quantitative polymerase chain reaction (QPCR)-based detection method following repeated HEPA vacuum cleanings. The QPCR method had a limit of detection corresponding to < or = 10(2) colony forming units per gram of settled dust. QPCR results were compared with measures of dust recoveries and fungal glucan and endotoxin levels in the dust samples. The largest fraction (ca. 81%) of added spores was recovered during the first HEPA cleaning. Subsequent cleanings resulted in incrementally lower recoveries, with removal of 93% of the initial inoculum by the third HEPA vacuuming. HEPA vacuuming prior to removal of items such as office contents and furnishings would result in much less resuspension of dust and limiting the extent of contamination. This approach also ensures that residual contaminants are as low as can be reasonably achieved.
Collapse
Affiliation(s)
- Luke Johnson
- Department of Chemistry, Carleton University, Ottawa, Ontario, Canada
| | | | | | | | | |
Collapse
|
30
|
Optimal swab processing recovery method for detection of bioterrorism-related Francisella tularensis by real-time PCR. J Microbiol Methods 2010; 83:42-7. [DOI: 10.1016/j.mimet.2010.07.015] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2010] [Revised: 07/13/2010] [Accepted: 07/13/2010] [Indexed: 01/29/2023]
|
31
|
Validation of a nylon-flocked-swab protocol for efficient recovery of bacterial spores from smooth and rough surfaces. Appl Environ Microbiol 2010; 76:5148-58. [PMID: 20543054 DOI: 10.1128/aem.00399-10] [Citation(s) in RCA: 66] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
In order to meet planetary-protection requirements, culturable bacterial spore loads are measured representatively for the total microbial contamination of spacecraft. However, the National Aeronautics and Space Administration's (NASA's) cotton swab protocols for spore load determination have not changed for decades. To determine whether a more efficient alternative was available, a novel swab was evaluated for recovery of different Bacillus atrophaeus spore concentrations on stainless steel and other surfaces. Two protocols for the nylon-flocked swab (NFS) were validated and compared to the present NASA standard protocol. The results indicate that the novel swab protocols recover 3- to 4-fold more (45.4% and 49.0% recovery efficiency) B. atrophaeus spores than the NASA standard method (13.2%). Moreover, the nylon-flocked-swab protocols were superior in recovery efficiency for spores of seven different Bacillus species, including Bacillus anthracis Sterne (recovery efficiency, 20%). The recovery efficiencies for B. atrophaeus spores from different surfaces showed a variation from 5.9 to 62.0%, depending on the roughness of the surface analyzed. Direct inoculation of the swab resulted in a recovery rate of about 80%, consistent with the results of scanning electron micrographs that allowed detailed comparisons of the two swab types. The results of this investigation will significantly contribute to the cleanliness control of future life detection missions and will provide significant improvement in detection of B. anthracis contamination for law enforcement and security efforts.
Collapse
|
32
|
Multigeneration cross contamination of mail with Bacillus species spores by tumbling. Appl Environ Microbiol 2010; 76:4797-804. [PMID: 20511424 DOI: 10.1128/aem.02978-09] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
In 2001, envelopes loaded with Bacillus anthracis spores were mailed to Senators Daschle and Leahy as well as to the New York Post and NBC News buildings. Additional letters may have been mailed to other news agencies because there was confirmed anthrax infection of employees at these locations. These events heightened the awareness of the lack of understanding of the mechanism(s) by which objects contaminated with a biological agent might spread disease. This understanding is crucial for the estimation of the potential for exposure to ensure the appropriate response in the event of future attacks. In this study, equipment to simulate interactions between envelopes and procedures to analyze the spread of spores from a "payload" envelope (i.e., loaded internally with a powdered spore preparation) onto neighboring envelopes were developed. Another process to determine whether an aerosol could be generated by opening contaminated envelopes was developed. Subsequent generations of contaminated envelopes originating from a single payload envelope showed a consistent two-log decrease in the number of spores transferred from one generation to the next. Opening a tertiary contaminated envelope resulted in an aerosol containing 10(3) B. anthracis spores. We developed a procedure for sampling contaminated letters by a nondestructive method aimed at providing information useful for consequence management while preserving the integrity of objects contaminated during the incident and preserving evidence for law enforcement agencies.
Collapse
|
33
|
Hong-Geller E, Valdez Y, Shou Y, Yoshida T, Marrone B, Dunbar J. Evaluation ofBacillus anthracisandYersinia pestissample collection from nonporous surfaces by quantitative real-time PCR. Lett Appl Microbiol 2010; 50:431-7. [DOI: 10.1111/j.1472-765x.2010.02821.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
34
|
National validation study of a swab protocol for the recovery of Bacillus anthracis spores from surfaces. J Microbiol Methods 2010; 81:141-6. [PMID: 20193714 DOI: 10.1016/j.mimet.2010.02.010] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2010] [Revised: 02/19/2010] [Accepted: 02/20/2010] [Indexed: 11/22/2022]
Abstract
Twelve Laboratory Response Network (LRN) affiliated laboratories participated in a validation study of a macrofoam swab protocol for the recovery, detection, and quantification of viable B. anthracis (BA) Sterne spores from steel surfaces. CDC personnel inoculated steel coupons (26cm(2)) with 1-4 log(10) BA spores and recovered them by sampling with pre-moistened macrofoam swabs. Phase 1 (P1) of the study evaluated swabs containing BA only, while dust and background organisms were added to swabs in Phase 2 (P2) to mimic environmental conditions. Laboratories processed swabs and enumerated spores by culturing eluted swab suspensions and counting colonies with morphology consistent with BA. Processed swabs were placed in enrichment broth, incubated 24h, and cultured by streaking for isolation. Real-time PCR was performed on selected colonies from P2 samples to confirm the identity of BA. Mean percent recovery (%R) of spores from the surface ranged from 15.8 to 31.0% (P1) and from 27.9 to 55.0% (P2). The highest mean percent recovery was 31.0% (sd 10.9%) for P1 (4 log(10) inoculum) and 55.0% (sd 27.6%) for P2 (1 log(10) inoculum). The overall %R was higher for P2 (44.6%) than P1 (24.1%), but the overall reproducibility (between-lab variability) was lower in P2 than in P1 (25.0 vs 16.5%CV, respectively). The overall precision (within-lab variability) was close to identical for P1 and P2 (44.0 and 44.1, respectively), but varied greatly between inoculum levels. The protocol demonstrated linearity in %R over the three inoculum levels and is able to detect between 26 and 5x10(6)spores/26cm(2). Sensitivity as determined by culture was >98.3% for both phases and all inocula, suggesting that the culture method maintains sensitivity in the presence of contaminants. The enrichment broth method alone was less sensitive for sampled swabs (66.4%) during P2, suggesting that the presence of background organisms inhibited growth or isolation of BA from the broth. The addition of real-time PCR testing to the assay increased specificity from >85.4% to >95.0% in P2. Although the precision was low at the 1 log(10) inoculum level in both phases (59.0 and 50.2%), this swab processing protocol, was sensitive, specific, precise, and reproducible at 2-4 log(10)/26cm(2) spore concentrations.
Collapse
|
35
|
Implications of limits of detection of various methods for Bacillus anthracis in computing risks to human health. Appl Environ Microbiol 2009; 75:6331-9. [PMID: 19648357 DOI: 10.1128/aem.00288-09] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
Used for decades for biological warfare, Bacillus anthracis (category A agent) has proven to be highly stable and lethal. Quantitative risk assessment modeling requires descriptive statistics of the limit of detection to assist in defining the exposure. Furthermore, the sensitivities of various detection methods in environmental matrices are vital information for first responders. A literature review of peer-reviewed journal articles related to methods for detection of B. anthracis was undertaken. Articles focused on the development or evaluation of various detection approaches, such as PCR, real-time PCR, immunoassay, etc. Real-time PCR and PCR were the most sensitive methods for the detection of B. anthracis, with median instrument limits of detection of 430 and 440 cells/ml, respectively. There were very few peer-reviewed articles on the detection methods for B. anthracis in the environment. The most sensitive limits of detection for the environmental samples were 0.1 CFU/g for soil using PCR-enzyme-linked immunosorbent assay (ELISA), 17 CFU/liter for air using an ELISA-biochip system, 1 CFU/liter for water using cultivation, and 1 CFU/cm(2) for stainless steel fomites using cultivation. An exponential dose-response model for the inhalation of B. anthracis estimates of risk at concentrations equal to the environmental limit of detection determined the probability of death if untreated to be as high as 0.520. Though more data on the environmental limit of detection would improve the assumptions made for the risk assessment, this study's quantification of the risk posed by current limitations in the knowledge of detection methods should be considered when employing those methods in environmental monitoring and cleanup strategies.
Collapse
|
36
|
Recovery efficiency and limit of detection of aerosolized Bacillus anthracis Sterne from environmental surface samples. Appl Environ Microbiol 2009; 75:4297-306. [PMID: 19429546 DOI: 10.1128/aem.02549-08] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
After the 2001 anthrax incidents, surface sampling techniques for biological agents were found to be inadequately validated, especially at low surface loadings. We aerosolized Bacillus anthracis Sterne spores within a chamber to achieve very low surface loading (ca. 3, 30, and 200 CFU per 100 cm(2)). Steel and carpet coupons seeded in the chamber were sampled with swab (103 cm(2)) or wipe or vacuum (929 cm(2)) surface sampling methods and analyzed at three laboratories. Agar settle plates (60 cm(2)) were the reference for determining recovery efficiency (RE). The minimum estimated surface concentrations to achieve a 95% response rate based on probit regression were 190, 15, and 44 CFU/100 cm(2) for sampling steel surfaces and 40, 9.2, and 28 CFU/100 cm(2) for sampling carpet surfaces with swab, wipe, and vacuum methods, respectively; however, these results should be cautiously interpreted because of high observed variability. Mean REs at the highest surface loading were 5.0%, 18%, and 3.7% on steel and 12%, 23%, and 4.7% on carpet for the swab, wipe, and vacuum methods, respectively. Precision (coefficient of variation) was poor at the lower surface concentrations but improved with increasing surface concentration. The best precision was obtained with wipe samples on carpet, achieving 38% at the highest surface concentration. The wipe sampling method detected B. anthracis at lower estimated surface concentrations and had higher RE and better precision than the other methods. These results may guide investigators to more meaningfully conduct environmental sampling, quantify contamination levels, and conduct risk assessment for humans.
Collapse
|