Leach CL, Davidson PJ, Hasselquist BE, Boudreau RJ. Lung deposition of hydrofluoroalkane-134a beclomethasone is greater than that of chlorofluorocarbon fluticasone and chlorofluorocarbon beclomethasone : a cross-over study in healthy volunteers.
Chest 2002;
122:510-6. [PMID:
12171824 DOI:
10.1378/chest.122.2.510]
[Citation(s) in RCA: 161] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
Abstract
STUDY OBJECTIVES
To compare the lung deposition of radiolabeled hydrofluoroalkane-134a beclomethasone dipropionate (HFA-BDP) with chlorofluorocarbon fluticasone propionate (CFC-FP) and chlorofluorocarbon beclomethasone (CFC-BDP).
DESIGN
Six-day, open-label, nonrandomized, crossover study.
SETTING
Clinical research laboratory.
PARTICIPANTS
Nine healthy, nonsmoking, adult volunteers.
INTERVENTIONS
On each study day, participants inhaled one or two puffs of 99mTc-labeled HFA-BDP, CFC-FP, or CFC-BDP. All products delivered 50 micro g per puff ex-valve. Subjects used a respiratory training and monitoring device to meet predefined, standardized inhalation patterns. Immediately after inhalation of radiolabeled study drug, planar gamma camera images were obtained.
MEASUREMENTS AND RESULTS
Radiolabeled HFA-BDP had a higher deposition in the lungs (53% ex-actuator) compared with CFC-FP (12 to 13%) and CFC-BDP (4%). Conversely, CFC-FP and CFC-BDP had a much higher distribution to the oropharynx (72 to 78%, and 82%, respectively) than HFA-BDP (29%). HFA-BDP was deposited evenly throughout the lungs, while CFC-FP and CFC-BDP deposition was primarily in the large central and intermediate airways. Andersen particle size sampling gave mass median aerodynamic diameters for HFA-BDP, CFC-FP, and CFC-BDP of 0.9 micro m, 2.0 micro m, and 3.5 micro m, respectively.
CONCLUSIONS
Lung deposition was greater with HFA-BDP compared with CFC-FP and CFC-BDP. Deposition values appeared to be related to the particle size distribution of each inhaler, with the smaller particles of HFA-BDP providing the greatest lung deposition and least oropharyngeal deposition.
Collapse