Hughes-Jones NC, Hunt VA, Maycock WD, Wesley ED, Vallet L. Anti-D immunoglobulin preparations: the stability of anti-D concentrations and the error of the assay of anti-D.
Vox Sang 1978;
35:100-4. [PMID:
96601 DOI:
10.1111/j.1423-0410.1978.tb02906.x]
[Citation(s) in RCA: 6] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
An analysis of the assay of 28 preparations of anti-D immunoglobulin using a radioisotope method carried out at 6-montly intervals for 2--4.5 years showed an average fall in anti-D concentration of 10.6% each year, with 99% confidence limits of 6.8--14.7%. The fall in anti-D concentration after storage at 37 degrees C for 1 month was less than 8%, the minimum change that could be detected. No significant change in physical characteristics of the immunoglobulin were detected. The error of a single estimate of anti-D by the radioisotope method (125I-labelled anti-IgG) used here was calculated to be such that the true value probably (p = 0.95) lay between 66 and 150% of the estimated value.
Collapse