1
|
Calixto ET, Kelmer VF, Komegae GH, Pacheco RR, Pini N, Sundfeld D. Influence of Varied Silane Commercial Brands and Adhesive Application on Bond Strength and Stability to Lithium Disilicate Glass Ceramic. Oper Dent 2024; 49:325-335. [PMID: 38632867 DOI: 10.2341/23-124-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/05/2023] [Indexed: 04/19/2024]
Abstract
OBJECTIVES This study aimed to evaluate the impact of various commercial silane brands with varied chemical compositions with or without the application of an adhesive layer on the microshear bond strength and durability of a resin luting agent to lithium disilicate glass ceramic. METHODS AND MATERIALS Lithium disilicate glass ceramic discs (EMX, IPS e.max Press, Ivoclar Vivadent) measuring 10 mm in diameter and 3 mm in thickness were fabricated (n=240). Surfaces were etched using 5% hydrofluoric acid and randomly assigned to 10 groups based on the commercial brand of silane used (n=24): [RP] RelyX Ceramic Primer (3M ESPE); [PS] Prosil (FGM); [SA] Silano (Angelus); [SM] Silano (Maquira); [SU] Silane (Ultradent); [GL] GLUMA Ceramic Primer (Kulzer); [CB] Ceramic Bond (VOCO); [MB] Monobond N (Ivoclar Vivadent); [CP] Clearfil Ceramic Primer (Kuraray); and [DE] 2-step silane (Dentsply Sirona). Half of the EMXs (n=12) received a thin adhesive layer (+) after the silane and prior to resin luting agent, while the other half (n=12) did not receive an adhesive layer (-). For the microshear bond strength test (μSBS), four light-cured resin luting agent cylinders (1 mm in diameter) were created on each EMX surface. Half of these specimens were tested after 24 hours, while the other half were stored in deionized water for 6 months. The μSBS test was conducted using a universal testing machine (DL 500, EMIC) at a crosshead speed of 1 mm/min until failure. The obtained data underwent statistical analysis using analysis of variance (ANOVA) and the Tukey test (α=0.05). RESULTS There was significant influence of the silane commercial brand on bond strength. Notably, "universal primers" yielded lower bond strength results compared to "pure" silane solutions. Water storage had a detrimental effect on microshear bond strength for certain silane commercial brands. Additionally, the application of an adhesive layer negatively impacted bond strength results for all silanes. CONCLUSIONS This study confirms the importance of both silane commercial brand and chemical composition in relation to bond strength of resin luting agents to lithium disilicate glass ceramic. Furthermore, the application of an adhesive layer may have an adverse effect on bond stability over time.
Collapse
Affiliation(s)
- E T Calixto
- Emerson Tavares Calixto, DDS, MSc student, Ingá University Center, Uningá, Maningá, PR, Brazil
| | - V F Kelmer
- Vinicius Fernandez Kelmer, DDS student, Ingá University Center, Uningá, Maningá, PR, Brazil
| | - G H Komegae
- Gabriely Hikari Komegae, DDS, MSc student, Ingá University Center, Uningá, Maningá, PR, Brazil
| | - R R Pacheco
- Rafael Rocha Pacheco, DDS, MSc, PhD, associate professor and section director of Dental Materials, Department of Restorative Sciences, The Dental College of Georgia at Augusta University, Augusta, GA, USA
| | - Nip Pini
- Nubia Inocencya Pavesi Pini, DDS, MSc, PhD, adjunct professor, School of Dentistry, Department of Restorative Dentistry and Prosthodontics, Ingá University Center, Uningá, Maningá, PR, Brazil
| | - D Sundfeld
- *Daniel Sundfeld, DDS, MSc, PhD, adjunct professor, Department of Restorative Dentistry and Prosthodontics, Ingá University Center, Uningá, Maningá, PR, Brazil
| |
Collapse
|
2
|
Alves LMM, Campos TMB, Bergamo ETP, Benalcazar Jalkh EB, Gierthmuehlen PC, Sailer I, Thim GP, Strazzi-Sahyon HB, Celestrino M, Guimarães CCL, Bonfante EA. Hydrofluoric acid concentration and etching time affect differently the microstructure and surface properties of pressed lithium disilicate glass ceramics. J ESTHET RESTOR DENT 2024; 36:47-55. [PMID: 37772362 DOI: 10.1111/jerd.13140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 09/07/2023] [Accepted: 09/11/2023] [Indexed: 09/30/2023]
Abstract
OBJECTIVE To evaluate the effect of different hydrofluoric acid concentrations and etching times on the surface, chemical composition and microstructure of lithium disilicate. MATERIAL AND METHODS Ninety specimens of pressed lithium disilicate (LDS) were obtained (IPS e.max Press, Rosetta SP and LiSi Press). The specimens of each material were divided in two groups according to the hydrofluoric acid concentration: 5% and 10% (n = 15/group), and subdivided according to the etching time: 20, 40 and 60 s (n = 5/group). Crystalline evaluations and chemical composition were performed through x-ray diffraction (XRD) and energy-dispersive x-ray spectroscopy (EDS), respectively. Microstructural analyses were performed by scanning electron microscope (SEM), surface roughness (Ra), and material thickness removal evaluation. Thickness removal and Ra data were analyzed by ANOVA and Tukey test (p < 0.05). RESULTS XRD demonstrated characteristic peaks of lithium disilicate crystals, lithium phosphate and of a vitreous phase for all materials. EDS identified different compositions and SEM confirmed different surface responses to acid etching protocols. Material and etching time influenced Ra and material thickness removal (p < 0.05). CONCLUSION Hydrofluoric acid concentration and etching time affect the surface characteristics of LDS differently. LiSi Press presented higher resistance to hydrofluoric acid etching compared to e.max Press and Rosetta SP. CLINICAL SIGNIFICANCE Applying the appropriate etching protocol is pivotal to avoid excessive material removal and to prevent jeopardize the mechanical and optical properties of the material.
Collapse
Affiliation(s)
- Larissa M M Alves
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Bauru, SP, Brazil
| | - Tiago M B Campos
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Bauru, SP, Brazil
| | - Edmara T P Bergamo
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Bauru, SP, Brazil
- Biomaterials Division, New York University College of Dentistry, New York, New York, USA
| | - Ernesto B Benalcazar Jalkh
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Bauru, SP, Brazil
| | - Petra C Gierthmuehlen
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany
| | - Irena Sailer
- Division of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Gilmar P Thim
- Department of Physics, Aeronautics Technological Institute, São José dos Campos, SP, Brazil
| | - Henrico B Strazzi-Sahyon
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Bauru, SP, Brazil
| | | | - Carolina C L Guimarães
- Department of Physics, Aeronautics Technological Institute, São José dos Campos, SP, Brazil
| | - Estevam A Bonfante
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Bauru, SP, Brazil
| |
Collapse
|
3
|
Manziuc M, Khechen AA, Negucioiu M, Poiană I, Kui A, Mesaroș A, Buduru S. Survival Rates of Glass versus Hybrid Ceramics in Partial Prosthetic Restorations: A Scoping Review with Emphasis on Adhesive Protocols. J Clin Med 2023; 12:6744. [PMID: 37959209 PMCID: PMC10647428 DOI: 10.3390/jcm12216744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 10/22/2023] [Accepted: 10/23/2023] [Indexed: 11/15/2023] Open
Abstract
As dental practices and methodologies evolve, the emergence of novel materials adds complexity to clinical choices. While glass ceramics, particularly those based on lithium disilicate and leucite-reinforced variants, have been extensively researched and are well regarded for their attributes, hybrid ceramics remain relatively recent area of research that is less investigated. This review aims to evaluate the durability of glass and hybrid ceramics while assessing the role of various adhesive techniques on restoration longevity. Using a comprehensive search of PubMed and EMBASE, 84 articles from the past decade were found. Only eleven met the set criteria for analysis. The results underscore the urgent need for the extended monitoring of partial prosthetic restorations. The existing literature has significant gaps, hindering the attainment of dependable insights about these materials' long-term performance. For a clearer understanding of how different ceramic systems affect restoration survival rates, rigorous research involving more participants and uniform outcome documentation is vital.
Collapse
Affiliation(s)
- Manuela Manziuc
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (M.M.); (S.B.)
| | - Alex Abbas Khechen
- Faculty of Dental Medicine, Iuliu Hatieganu University of Medicine and Pharmacy, 8 Victor Babeș Street, 400008 Cluj-Napoca, Romania
| | - Marius Negucioiu
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (M.M.); (S.B.)
| | - Irina Poiană
- Cluj County Emergency Clinical Hospital, 3-5 Clinicilor Street, 400006 Cluj-Napoca, Romania
| | - Andreea Kui
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (M.M.); (S.B.)
| | - Anca Mesaroș
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (M.M.); (S.B.)
| | - Smaranda Buduru
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (M.M.); (S.B.)
| |
Collapse
|
4
|
Al-Johani H, Haider J, Silikas N, Satterthwaite J. Effect of surface treatments on optical, topographical and mechanical properties of CAD/CAM reinforced lithium silicate glass ceramics. Dent Mater 2023; 39:779-789. [PMID: 37438204 DOI: 10.1016/j.dental.2023.07.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 06/21/2023] [Accepted: 07/04/2023] [Indexed: 07/14/2023]
Abstract
OBJECTIVES To investigate the effect of different surface treatments on optical, topographical and mechanical properties of CAD/CAM lithium silicate-based glass ceramics (LSC's) and their combined effect on the output of a light curing unit (LCU). METHODS Four CAD/CAM LSC's were investigated: Lithium Disilicate (Emax CAD; EC), Zirconia-reinforced silicates (Vita Suprinity; VS and Celtra Duo;CD) and Lithium Aluminum Disilicate (CEREC Tessera; CT). Ceramic specimens (n = 240) were divided into six subgroups according to their surface treatment: (a) Control, (b) Hydrofluoric acid (HF) 5%, (c) HF 5% + Neutralizing agent (N), (d) HF 9%, (e) HF 9% +N and (f) Self-etching ceramic primer (SEP). Irradiance, power and radiant exposure of a LCU were measured with MARC-LC following ceramic specimen interposition. Direct light transmission (T%) and absorbance (Abs%) of the specimens were measured with UV-Vis spectrophotometry. Roughness (Sa, Sq) and wettability (θ°) were measured with optical profilometry and sessile drop profile analysis, respectively. Biaxial flexural strength (σ) of the ceramic specimens was measured by the ball-on-three-balls method and ceramic specimens were examined microscopically. Statistical analyses was performed by two-way ANOVA followed by post hoc multiple comparisons (α = 0.05). RESULTS Acid neutralization decreased T% and increased Abs% in all LSC's and highest T% was exhibited with VS. Neutralized EC, VS and CD displayed higher Sa in HF9, while neutralized CT displayed higher Sa in HF5. Self-etch primer significantly reduced θ° (p < 0.001). σ was observed in the followed ascending order: HF9 +N < HF9 < HF5 +N < HF5 < SEP < Control for all LSC's. SIGNIFICANCE Optical, topographical and mechanical properties of the CAD/CAM ceramic blocks were strongly dependent on the type of surface treatment. Results of neutralization post-etching indicate promising potential for future investigations.
Collapse
Affiliation(s)
- Hanan Al-Johani
- Division of Dentistry, School of Medical Sciences, University of Manchester, UK; Department of Restorative Dentistry, Division of Biomaterials, Faculty of Dentistry, King Abdulaziz University, Saudi Arabia
| | - Julfikar Haider
- Division of Dentistry, School of Medical Sciences, University of Manchester, UK; Department of Engineering, Manchester Metropolitan University, Manchester, United Kingdom
| | - Nick Silikas
- Division of Dentistry, School of Medical Sciences, University of Manchester, UK.
| | | |
Collapse
|
5
|
Nogueira IDO, Pereira CNDB, Abreu LG, Diniz IMA, Magalhães CSD, Silveira RRD. Do different protocols affect the success rate or bond strength of glass-ceramics repaired with composite resin? A systematic review and meta-analysis. J Prosthet Dent 2023:S0022-3913(23)00432-8. [PMID: 37635007 DOI: 10.1016/j.prosdent.2023.06.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 06/25/2023] [Accepted: 06/26/2023] [Indexed: 08/29/2023]
Abstract
STATEMENT OF PROBLEM Intraoral repair techniques prevent unnecessary replacement of ceramic restorations, thereby increasing the survival rate. However, adhesion between ceramics and the composite resin is challenging and how different protocols influence adhesion is unclear. PURPOSE The purpose of this systematic review and meta-analysis was to analyze the influence of different protocols on repairing glass-ceramic surfaces with composite resins. MATERIAL AND METHODS PubMed, Scopus, ISI Web of Science, and Embase electronic databases were searched to select studies comparing bond strength values or survival rates of glass-ceramic repaired with composite resins using different surface treatment protocols. No publication year or language restriction was applied. Data sets were extracted from all included studies, and the mean differences calculated. A 95% confidence interval was calculated by using the random effect model (Rev Man 5.4). RESULTS The search identified 5037 studies, and 165 were assessed for eligibility. Finally, 123 in vitro studies were included in the systematic review and 48 in the meta-analysis. Considering different glass-ceramics, bond strength tests, and aged or not aged specimens, 37 meta-analyses found the effect of repair protocols: only adhesive, silane plus adhesive alone or preceded by hydrofluoric (HF) acid, airborne-particle abrasion (APA) with Al2O3 particles, silica-coated APA (SCAPA), diamond rotary instrument (DRI), and laser irradiation (LI). CONCLUSIONS For feldspathic porcelain, HF acid, APA, SCAPA, or DRI improved the repair micromechanical retention; applying silane is essential to HF-conditioned surfaces but the use of adhesive is optional when silane is applied. Results for leucite and lithium disilicate were inconclusive in terms of suggesting a treatment other than HF acid plus silane and adhesive applications.
Collapse
Affiliation(s)
- Iara de O Nogueira
- Department of Restorative Dentistry, Federal University of Minas Gerais (UFMG), Belo Horizonte, Minas Gerais, Brazil
| | - Carolina N de B Pereira
- Department of Restorative Dentistry, Federal University of Minas Gerais (UFMG), Belo Horizonte, Minas Gerais, Brazil
| | - Lucas G Abreu
- Department of Child and Adolescent Oral Health, Federal University of Minas Gerais (UFMG), Belo Horizonte, Minas Gerais, Brazil..
| | - Ivana M A Diniz
- Department of Restorative Dentistry, Federal University of Minas Gerais (UFMG), Belo Horizonte, Minas Gerais, Brazil
| | - Cláudia S de Magalhães
- Department of Restorative Dentistry, Federal University of Minas Gerais (UFMG), Belo Horizonte, Minas Gerais, Brazil
| | - Rodrigo R da Silveira
- Department of Restorative Dentistry, Federal University of Minas Gerais (UFMG), Belo Horizonte, Minas Gerais, Brazil
| |
Collapse
|
6
|
Effects of Two Different Acid Etching and Surface Washing Methods on Bond Strength on Different CAD-CAM Blocks under Aging Protocols. BIOMED RESEARCH INTERNATIONAL 2023. [DOI: 10.1155/2023/7982813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Aim. The purpose of this study is to investigate the effects of hydrofluoric acid and one-component ceramic primer and silane (Monobond Etch and Prime (MEP)) applications on lithium disilicate glass ceramics and zirconium-infiltrated lithium silicate glass ceramics, as well as the effect of ultrasonic and phosphoric acid surface washing methods on bond strength. Materials and Method. A total of 240 ceramic samples were prepared using two different CAD-CAM material blocks with a thickness of 2 mm made of lithium disilicate glass-ceramic (IPS e.max CAD) and zirconium-infiltrated lithium silicate glass ceramic blocks (Celtra Duo). The samples were cemented to the composite discs (Tetric N-Ceram) after two different acid treatments, and surface washing processes were applied to them. As such, 24 groups were formed, each with two different acid applications, three different washing processes, two different CAD-CAM blocks, and two different aging procedures (
). Following the application of the acid, different washing processes are used. These were HF acid and washing only (HF + W), HF acid and ultrasonic washing (HF + US), HF acid and phosphoric acid (HF + PA), MEP with washing only (MEP + W), MEP and ultrasonic washing (MEP + US), and MEP and phosphoric acid (MEP + PA). The composite discs were cemented with dual cure adhesive cement (Multilink Automix) after the determined surface treatments were applied to the blocks. After surface applications, SEM analysis was conducted. Following exposure to two different thermal procedures, long-term (TL) and short-term (TS), bond strengths were measured using an Instron universal test device. SPSS version 23.0 software was used to perform the statistical analyses. Histogram graphs and the Kolmogorov-Smirnov/Shapiro-Wilk test were used to assess the variables’ conformity to the normal distribution. Results. The bond strength values of TS and TL in the Celtra Duo block were significantly higher than those in the e.max CAD block (
). The TS-TL bonding strength value difference in the e.max CAD block was significantly higher than the surface measurements in the Celtra Duo block. While the highest bond strength value HF + US for TS in e.max CAD was
, the values of HF + US in Celtra Duo were significantly higher in terms of TL values when compared to other groups. Conclusion. Celtra Duo material demonstrated higher bond strength values after a short and long thermal cycle than e.max CAD material. In general, groups bonded with HF were less affected by the thermal cycle than groups treated with MEP.
Collapse
|
7
|
Approaches to Preceramic Polymer Fiber Fabrication and On-Demand Applications. MATERIALS 2022; 15:ma15134546. [PMID: 35806670 PMCID: PMC9267150 DOI: 10.3390/ma15134546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 06/21/2022] [Accepted: 06/24/2022] [Indexed: 12/04/2022]
Abstract
The demand for lightweight, high-modulus, and temperature-resistant materials for aerospace and other high-temperature applications has contributed to the development of ceramic fibers that exhibit most of the favorable properties of monolithic ceramics. This review demonstrates preceramic-based polymer fiber spinning and fiber classifications. We discuss different types of fiber spinning and the advantages of each. Tuning the preceramic polymer chemical properties, molar mass, functional chemistry influences, and incorporation with fillers are thoroughly investigated. Further, we present the applications of preceramic-based polymer fibers in different fields including aerospace, biomedical, and sensor applications. This concise review summarizes recent developments in preceramic fiber chemistry and essential applications.
Collapse
|
8
|
Fagan J, Vesselovcz J, Puppin-Rontani J, Correr-Sobrinho L, Freitas KMS, Robertson TC, Pacheco RR, Pini NIP, Sundfeld D. Evaluation of Cleaning Methods on Lithium Disilicate Glass Ceramic Surfaces After Organic Contamination. Oper Dent 2022; 47:E81-E90. [DOI: 10.2341/20-176-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/24/2021] [Indexed: 11/23/2022]
Abstract
SUMMARY
The purposes of this study were to 1) evaluate the effectiveness of different cleaning methods from a previously etched and silanized lithium disilicate glass ceramic (EMX) surface after contact with organic fluids (saliva or human blood) and 2) assess the effect of applying a new silane layer after the cleaning methods on the microshear bond strength (mSBS) of resin cement to EMX. EMX discs were etched with 5% hydrofluoric acid (HF) and properly silanized. Three control groups were created (n=10): control (without contamination), saliva positive, and human blood positive. Later, after new contaminations, the samples were distributed into four groups according to the cleaning method (n=20): air–water spray (AWS), 35% phosphoric acid, 70% alcohol, or Ivoclean cleaning paste. After the cleaning methods, subgroups were submitted to a new silane layer application, or not (n=10). All samples received a thin layer of a bonding agent and, subsequently, three light-cured resin cement cylinders were prepared on each EMX surface for the mSBS test. This test was performed on a universal testing machine at a vertical speed of 1 mm/minute until rupture. Contaminated and cleaned silanized EMX surfaces were assessed by scanning electron microscopy (SEM) (n=1). The noncontaminated control group showed an average mSBS of 18.7 MPa, and the positive saliva and human blood control groups yielded a 34% and 42% reduction in bond strength, respectively, compared to the uncontaminated control (p<0.05). For saliva-contaminated surfaces, all cleaning methods were effective and not different from one another or the control group (p>0.05). However, for human blood contamination, only Ivoclean cleaning paste was effective in restoring μSBS to uncontaminated control group levels (p>0.05). SEM images showed a clean surface (ie, with no contaminant residues) after the cleaning methods, regardless of the organic contaminant type. All the assessed cleaning methods were effective in removing saliva from the silanized EMX surface; however, only Ivoclean was able to restore the adhesion quality when the silanized EMX surface was contaminated with human blood.
Collapse
Affiliation(s)
- J Fagan
- João Fagan Junior, DDS, MSc student, Department of Restorative Dentistry and Prosthodontics, Ingá University Center – UNINGÁ, Maringá, PR, Brazil
| | - J Vesselovcz
- João Vesselovcz Junior, DDS, MSc student, Department of Restorative Dentistry and Prosthodontics, Ingá University Center – UNINGÁ, Maringá, PR, Brazil
| | - J Puppin-Rontani
- Júlia Puppin Rontani, DDS, MSc, PhD, Dental Materials Division, Piracicaba School of Dentistry – UNICAMP, Piracicaba, SP, Brazil
| | - L Correr-Sobrinho
- Lourenço Correr Sobrinho, DDS, MSc, PhD, professor, Dental Materials Division, Piracicaba School of Dentistry – UNICAMP, Piracicaba, SP, Brazil
| | - KMS Freitas
- Karina Maria Salvatore de Freitas, DDS, MSc, PhD, professor, Department of Orthodontics and Pediatric Dentistry, Ingá University Center – UNINGÁ, Maringá, PR, Brazil
| | - TC Robertson
- Taylor Cliffe Robertson, DDS candidate, University of Detroit Mercy, School of Dentistry, Detroit, MI, USA
| | - RR Pacheco
- Rafael Rocha Pacheco, DDS, MSc, PhD, assistant professor, Restorative Dentistry, University of Detroit Mercy, School of Dentistry, Detroit, MI, USA
| | - NIP Pini
- Nubia Inocêncya Pavesi Pini, DDS, MSc, PhD, adjunct professor, Department of Restorative Dentistry and Prosthodontics, Ingá University Center – UNINGÁ, Maringá, PR, Brazil
| | - D Sundfeld
- *Daniel Sundfeld, DDS, MSc, PhD, adjunct professor, Department of Restorative Dentistry and Prosthodontics, Ingá University Center – UNINGÁ, Maringá, PR, Brazil
| |
Collapse
|
9
|
Hashemikamangar S, Kiomarsi N, Jarrah A, Chiniforoush N, Kharazifard M. Effect of surface treatment with laser on repair bond strength of composite resin to ceramic. Dent Res J (Isfahan) 2022. [DOI: 10.4103/1735-3327.340115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
10
|
Using Geopolymer Technology on Synthesizing Leucite Ceramics. Polymers (Basel) 2021; 13:polym13213621. [PMID: 34771177 PMCID: PMC8587864 DOI: 10.3390/polym13213621] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Revised: 10/18/2021] [Accepted: 10/18/2021] [Indexed: 11/17/2022] Open
Abstract
The aim of this study is to assess the process of synthesizing potassium-based geopolymers (KGL) into leucite ceramics with regard to five variables, namely, alkaline solution ratio (R), sintering time (S), calcining temperature (T), mixing time (M), and curing time (C). Under these conditions, the specimens were tested by the viscosity test, the mechanical properties test, X-ray diffraction (XRD), Fourier-transform infrared (FTIR) spectroscopy, and scanning electron microscopy (SEM) to understand the geopolymerization reactions and the characteristics of the KGL network. The results indicate that a KOH to K2O/SiO2 ratio of 1:1 promotes the reaction within metakaolin. XRD analysis of the KGL shows that, when the temperature is 1100 °C, the phase transforms into the leucite phase. Moreover, XRD analysis, mechanical properties, and FTIR all indicate improved characteristics when the curing time increases from 1 to 8 h. This might be attributed to the enhancement of the strong interaction between the matrix and the alkaline solution upon achieving adequate time to complete the geopolymerization process and forming a more stable three-dimensional structure. The formulation which formed the purest leucite phase consisted of: a 1:1 alkaline solution ratio, 10 min mixing time, 8 h curing time, 1200 °C calcining temperature, and 2 h sintering time.
Collapse
|
11
|
Simple Approach to Medical Grade Alumina and Zirconia Ceramics Surface Alteration via Acid Etching Treatment. CRYSTALS 2021. [DOI: 10.3390/cryst11101232] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
In order for bioceramics to be further used in composites and their applications, it is important to change the surface so that the inert material is ready to interact with another material. Medical grade alumina and zirconia ceramic powders have been chemically etched with three selected acidic mixtures. Powder samples were taken for characterization, which was the key to evaluating a successful surface change. Changes in morphology, together with chemical composition, were studied using scanning electron microscopy, phase composition using X-ray diffraction methods, and nitrogen adsorption/desorption isotherms are used to evaluate specific surface area and porosity. The application of HF negatively affected the morphology of the material and caused agglomeration. The most effective modification of ceramic powders was the application of a piranha solution to obtain a new surface and a satisfactory degree of agglomeration. The prepared micro-roughness of the etched ceramic would provide an improved surface of the material either for its next step of incorporation into the selected matrix or to directly aid in the attachment and proliferation of osteoblast cells.
Collapse
|
12
|
Effects of the ratio of silane to 10-methacryloyloxydecyl dihydrogenphosphate (MDP) in primer on bonding performance of silica-based and zirconia ceramics. J Mech Behav Biomed Mater 2020; 112:104026. [DOI: 10.1016/j.jmbbm.2020.104026] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 07/31/2020] [Accepted: 08/02/2020] [Indexed: 11/17/2022]
|
13
|
AL‐Turki L, Merdad Y, Abuhaimed TA, Sabbahi D, Almarshadi M, Aldabbagh R. Repair bond strength of dental computer‐aided design/computer‐aided manufactured ceramics after different surface treatments. J ESTHET RESTOR DENT 2020; 32:726-733. [DOI: 10.1111/jerd.12635] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Revised: 06/22/2020] [Accepted: 07/18/2020] [Indexed: 11/29/2022]
Affiliation(s)
- Lulwa AL‐Turki
- Department of Oral and Maxillofacial Prosthodontics, Faculty of Dentistry King Abdulaziz University Jeddah Saudi Arabia
| | - Yasser Merdad
- Department of Operative Dentistry, Faculty of Dentistry King Abdulaziz University Jeddah Saudi Arabia
| | - Tariq A. Abuhaimed
- Department of Operative Dentistry, Faculty of Dentistry King Abdulaziz University Jeddah Saudi Arabia
| | - Dania Sabbahi
- Department of Dental Public Health, Faculty of Dentistry King Abdulaziz University Jeddah Saudi Arabia
| | | | - Raghad Aldabbagh
- Department of Oral and Maxillofacial Prosthodontics, Faculty of Dentistry King Abdulaziz University Jeddah Saudi Arabia
| |
Collapse
|
14
|
Veríssimo AH, Duarte Moura DM, de Oliveira Dal Piva AM, Bottino MA, de Fátima Dantas de Almeida L, da Fonte Porto Carreiro A, de Assunção e Souza RO. Effect of different repair methods on the bond strength of resin composite to CAD/CAM materials and microorganisms adhesion: An in situ study. J Dent 2020; 93:103266. [DOI: 10.1016/j.jdent.2019.103266] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Revised: 12/06/2019] [Accepted: 12/17/2019] [Indexed: 10/25/2022] Open
|
15
|
Tribst JPM, Dal Piva AMDO, Madruga CFL, Valera MC, Bresciani E, Bottino MA, de Melo RM. The impact of restorative material and ceramic thickness on CAD\CAM endocrowns. J Clin Exp Dent 2019; 11:e969-e977. [PMID: 31700569 PMCID: PMC6825739 DOI: 10.4317/jced.56002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Accepted: 09/09/2019] [Indexed: 12/01/2022] Open
Abstract
Background Endocrown restorations as a conservative approach to restore endodontically treated teeth still need in vitro investigation under fatigue and made in different materials. This study evaluated the effect of restorative material and restoration thickness on the maximum fracture load of endocrowns subjected to cyclic loading. Material and Methods Sixty (60) third molar teeth received an endocrown preparation with three different heights of remaining dental tissue (1.5, 3.0 or 4.5 mm). A leucite-based ceramic (LEU) and a lithium disilicate (LD) based ceramic were selected to manufacture the CAD/CAM endocrown restorations, totaling 6 groups (n=10). The specimens were subjected to fatigue loading (200N, 2 x 106 cycles, water) and then to the single load to failure test (1 mm/min crosshead speed). Data were analyzed by using two-way ANOVA and Tukey tests (p< 0.05). Results All endocrowns survived the fatigue test. The thickness did not influence the restoration’s fracture load (p=0.548) instead the restorative material (p=0.003). LD showed higher mean values (1714.43 N)A than LEU (1313.47 N)B. Conclusions Endocrowns manufactured with CAD/CAM lithium disilicate blocks showed superior fracture load than the leucite-based blocks after mechanical fatigue. Nevertheless, both materials presented acceptable survival and fracture load as long as the material’s minimum thickness and the enamel adhesion are respected. Key words:Endocrown, CAD/CAM, Endodontically treated teeth, Failure load, Minimal intervention dentistry.
Collapse
Affiliation(s)
- João-Paulo-Mendes Tribst
- DDs, MSc, PhD Student in Prosthodontics, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil
| | - Amanda-Maria-de Oliveira Dal Piva
- DDs, MSc, PhD Student in Prosthodontics, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil
| | - Camila-Ferreira-Leite Madruga
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, n° 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil
| | - Marcia-Carneiro Valera
- Department of Restorative Dentistry, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, n° 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil
| | - Eduardo Bresciani
- Department of Restorative Dentistry, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, n° 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil
| | - Marco-Antonio Bottino
- DDs, MSc, PhD, Professor, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil
| | - Renata-Marques de Melo
- DDs, MSc, PhD, Researcher III, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil
| |
Collapse
|
16
|
Masri DM, Alghamdi NS, Alhawiti NS, Alawi RM, Alhothari SK, Yousief SA, Mekky MA. Effect of Surface Treatments on the Shear Bond Strength of Indirect Esthetic Restorative Materials to Dentin. Open Access Maced J Med Sci 2019; 7:2528-2532. [PMID: 31666859 PMCID: PMC6814474 DOI: 10.3889/oamjms.2019.724] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2019] [Revised: 07/23/2019] [Accepted: 07/24/2019] [Indexed: 11/05/2022] Open
Abstract
AIM The purpose of this research was to evaluate the influence of air abrasion, hydrofluoric acid, and combination of air abrasion and hydrofluoric acid on the shear bond strength between dentin and CEREC, VITA VM7, and E-max. MATERIAL AND METHODS Ninety extracted human lower molars were used. The teeth were divided into three groups (n = 30) according to the surface treatment (air abrasion, hydrofluoric acid, and air abrasion + hydrofluoric acid). Each group was then subdivided into three subgroups (n = 10) according to the ceramic material (CEREC, E-max, and VITA VM7). Shear bond strength was determined by the compressive mode of force applied at the ceramic-tooth interface. The collected data were analysed using two-way analysis of variance (ANOVA), and Tukey's post-hoc test statistical significance was set at P < 0.05. RESULTS The highest mean shear bond strength value was recorded with the CEREC group treated by hydrofluoric acid (8.01MPa). While the least mean shear bond strength was recorded with the Cerec group but when treated by air abrasion alone, it was 4.33MPa. CONCLUSION Hydrofluoric acid etching for various types of ceramic restoration improved the bond strength to dentin.
Collapse
Affiliation(s)
- Dhuha M Masri
- Alfarabi Private Dental College for Dentistry and Nursing, Jeddah, Saudi Arabia
| | - Nisreen S Alghamdi
- Alfarabi Private Dental College for Dentistry and Nursing, Jeddah, Saudi Arabia
| | - Najoud S Alhawiti
- Alfarabi Private Dental College for Dentistry and Nursing, Jeddah, Saudi Arabia
| | - Renad M Alawi
- Alfarabi Private Dental College for Dentistry and Nursing, Jeddah, Saudi Arabia
| | - Shroug K Alhothari
- Alfarabi Private Dental College for Dentistry and Nursing, Jeddah, Saudi Arabia
| | - Salah A Yousief
- Restorative Dental Science, Alfarabi Private Dental College, Jeddah, Saudi Arabia.,Faculty of Dental Medicine, Al Azhar University, Assuit Branch, Cairo, Egypt
| | - Mahmoud A Mekky
- Faculty of Dental Medicine, South Valley University, Qena, Egypt
| |
Collapse
|
17
|
Ferreira da Silva DF, Lopes RDO, Caetano de Souza N, Marcondes ML, Danesi P, Spohr AM. Bond to Zirconia Ceramic: Evaluation of Different Primers and a Universal Adhesive. Open Dent J 2018. [DOI: 10.2174/1874210601812010929] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Objective:
The aim of the study was to evaluate the effect of a universal adhesive and different primers on the bond strength to zirconia ceramic.
Materials and Methods:
Seventy-five zirconia ceramic samples were obtained and divided into five groups (n=15): G1–Scothbond Universal (SBU); G2 – silane + SBU; G3 - Signum Zirconia Bond; G4 - Z-Prime Plus; G5 - MZ Primer. A cone of composite resin was built. The specimens were stored in 100% relative humidity with distilled water at 37°C for 48 h and then submitted to a tensile bond strength test in a universal testing machine at a crosshead speed of 0.5 mm/min. The type of failure that occurred during the de-bonding procedure was analyzed.
Results:
The mean results of the bond strength test (MPa) followed by the same letter represent no statistical difference by ANOVA and Tukey’s post-hoc test (p<0.05): G2=27.55a (±6.99), G4=23.71a (±5.65), G1=22.64a (±5.67), G5=13.64b (±5.49), G3=7.54c (±4.75). G2 and G4 exhibited predominantly cohesive failure in the composite resin cone. G1 and G5 had predominantly mixed failures, and G3 exhibited only adhesive failures.
Conclusion:
The SBU and Z-Prime Plus provided higher bond strength to zirconia ceramic.
Collapse
|
18
|
Tribst J, Anami LC, Özcan M, Bottino MA, Melo RM, Saavedra G. Self-etching Primers vs Acid Conditioning: Impact on Bond Strength Between Ceramics and Resin Cement. Oper Dent 2018. [PMID: 29513637 DOI: 10.2341/16-348-l] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study tested whether a self-etching surface agent and the conventional hydrofluoric acid (HF) would provide the same bonding capacity between resin cement and feldspathic (Fd) and lithium disilicate (Ld) ceramics. Ceramic blocks were cut with a low-speed diamond saw with water cooling (Isomet 1000, Buehler, Lake Bluff, IL, USA) into 20 blocks of 5 × 7 × 4 mm, which were ground flat in a polishing machine (EcoMet/AutoMet 250, Buehler) under water cooling. The blocks were randomly divided into eight groups (n=5), according to ceramic type (Ld or Fd), surface conditioning (HF + Monobond Plus or Etch and Prime), and aging by thermocycling (TC or absence-baseline). After 24 hours in 37°C distilled water, blocks were embedded into acrylic resin and 1-mm2 cross-section beams composed of ceramic/cement/composite were obtained. The microtensile test was performed in a universal testing machine (DL-1000, EMIC, São José dos Campos, Brazil; 0.5 mm.min-1, 50 kgf load cell). Bond strength (MPa) was calculated by dividing the load at failure (in N) by the bonded area (mm2). The fractured specimens were examined under stereomicroscopy, and one representative sample of each group was randomly selected before the cementation and was further used for analysis using scanning electron microscopy (SEM) and energy-dispersive x-ray spectroscopy (EDS). The self-etching agent showed the highest bond strength for Fd (24.66±4.5) and Ld (24.73±6.9) ceramics and a decrease in surface wettability. SEM and EDS showed the presence of similar components in the tested materials with different topographies for both. Therefore, the self-etching primer was able to deliver even higher bonding than HF+silane to a resin cement.
Collapse
|