1
|
Kolseth SM, Saeed S, Salminen PR, Ellensen VS, Kvalheim VL, Ali AM, Haaverstad R. A rapid deployment valve option for failing Medtronic Freestyle full root: a single centre experience. J Cardiothorac Surg 2024; 19:667. [PMID: 39707448 DOI: 10.1186/s13019-024-03178-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2024] [Accepted: 12/01/2024] [Indexed: 12/23/2024] Open
Abstract
BACKGROUND There are several high-risk treatment options for valve failure of a biological full root replacement. When tailoring the best treatment option for the patient, implantation of a rapid deployment valve (RDV) should be considered. CASE PRESENTATION Six patients presented with aortic regurgitation in a full root Freestyle bioprosthesis. Three had a history of valve endocarditis, while the remaining had non-infectious structural valve deterioration with leaflet and commissural tears. All patients were treated with a rapid deployment EDWARDS INTUITY Elite valve. Follow-up was complete for all patients. Postoperative echocardiography showed well-functioning valve prostheses with no paravalvular leaks and acceptable pressure gradients. Echocardiographic follow-up demonstrated excellent pressure gradients and a considerable decrease in the left ventricular mass index and left ventricular end-diastolic dimensions. Follow-up cardiac CT showed no signs of coronary obstruction or other pathology. During a median follow-up of 30 months neither biological valve failure, nor any events within the composite endpoint of major adverse cardiac and cerebrovascular events occurred. CONCLUSIONS This case series presents the EDWARDS INTUITY valve as a good treatment option in patients with failing Freestyle roots.
Collapse
Affiliation(s)
- Solveig Moss Kolseth
- Department of Heart Disease, Haukeland University Hospital, Jonas Lies vei 65, Bergen, 5021, Norway.
| | - Sahrai Saeed
- Department of Heart Disease, Haukeland University Hospital, Jonas Lies vei 65, Bergen, 5021, Norway
| | - Pirjo-Riitta Salminen
- Department of Heart Disease, Haukeland University Hospital, Jonas Lies vei 65, Bergen, 5021, Norway
| | - Vegard Skalstad Ellensen
- Department of Heart Disease, Haukeland University Hospital, Jonas Lies vei 65, Bergen, 5021, Norway
| | - Venny Lise Kvalheim
- Department of Heart Disease, Haukeland University Hospital, Jonas Lies vei 65, Bergen, 5021, Norway
- Department of Clinical Sciences, The Medical Faculty, University of Bergen, Bergen, Norway
| | - Abukar Mohamed Ali
- Department of Heart Disease, Haukeland University Hospital, Jonas Lies vei 65, Bergen, 5021, Norway
| | - Rune Haaverstad
- Department of Heart Disease, Haukeland University Hospital, Jonas Lies vei 65, Bergen, 5021, Norway
- Department of Clinical Sciences, The Medical Faculty, University of Bergen, Bergen, Norway
| |
Collapse
|
2
|
Spadaccio C, Nenna A, Pisani A, Laskawski G, Nappi F, Moon MR, Biancari F, Jassar AS, Greason KL, Shrestha ML, Bonaros N, Rose D. Sutureless Valves, a "Wireless" Option for Patients With Aortic Valve Disease: JACC State-of-the-Art Review. J Am Coll Cardiol 2024; 84:382-407. [PMID: 39019533 DOI: 10.1016/j.jacc.2024.05.031] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 03/21/2024] [Accepted: 05/03/2024] [Indexed: 07/19/2024]
Abstract
Transcatheter technologies triggered the recent revision of the guidelines that progressively widened the indications for the treatment of aortic stenosis. On the surgical realm, a technology avoiding the need for sutures to anchor the prosthesis to the aortic annulus has been developed with the aim to reduce the duration of cardiopulmonary bypass and simplify the process of valve implantation. In addition to a transcatheter aortic valve replacement (TAVR)-like stent that exerts a radial force, these so-called "rapid deployment valves" or "sutureless valves" for aortic valve replacement also have cuffs to improve sealing and reduce the risk of paravalvular leak. Despite promising, the actual advantage of sutureless valves over traditional surgical procedures (surgical aortic valve replacement) or TAVR is still debated. This review summarizes the current comparative evidence reporting outcomes of "sutureless valves" for aortic valve replacement to TAVR and surgical aortic valve replacement in the treatment of aortic valve stenosis.
Collapse
Affiliation(s)
- Cristiano Spadaccio
- Cardiothoracic Surgery, Lancashire Cardiac Centre/Blackpool Teaching Hospital, Blackpool, United Kingdom; Cardiovascular Surgery, Mayo Clinic, Rochester, Minnesota, USA.
| | - Antonio Nenna
- Cardiovascular Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Rome, Italy
| | - Angelo Pisani
- Cardiac Surgery, Hôpital Bichat - Claude-Bernard, Paris, France
| | - Grzegorz Laskawski
- Cardiothoracic Surgery, Lancashire Cardiac Centre/Blackpool Teaching Hospital, Blackpool, United Kingdom
| | - Francesco Nappi
- Cardiac Surgery, Centre Cardiologique du Nord de Saint-Denis, Paris, France
| | - Marc R Moon
- Cardiothoracic Surgery, Baylor College of Medicine/Texas Heart Institute, Houston, Texas, USA
| | - Fausto Biancari
- Heart and Lung Center, Helsinki University Hospital/University of Helsinki, Helsinki, Finland
| | - Arminder S Jassar
- Cardiac Surgery, Massachusetts General Hospital (MGH), Boston, Massachusetts, USA
| | - Kevin L Greason
- Cardiovascular Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | - Malakh L Shrestha
- Cardiovascular Surgery, Mayo Clinic, Rochester, Minnesota, USA; Cardiothoracic Surgery, Hannover Medical School, Hannover, Germany
| | - Nikolaos Bonaros
- Cardiac Surgery, Medical University of Innsbruck, Innsbruck, Austria
| | - David Rose
- Cardiothoracic Surgery, Lancashire Cardiac Centre/Blackpool Teaching Hospital, Blackpool, United Kingdom
| |
Collapse
|
3
|
Fatehi Hassanabad M, Fatehi Hassanabad A, Ahsan MR. The Novel Use of a Rapid Deployment Valve in Type A Aortic Dissection. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2024; 19:213-214. [PMID: 38504088 PMCID: PMC11059079 DOI: 10.1177/15569845241237732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/21/2024]
Affiliation(s)
- Mortaza Fatehi Hassanabad
- Section of Cardiac Surgery, Department of Cardiac Sciences, Libin Cardiovascular Institute, University of Calgary, AB, Canada
| | - Ali Fatehi Hassanabad
- Section of Cardiac Surgery, Department of Cardiac Sciences, Libin Cardiovascular Institute, University of Calgary, AB, Canada
| | - Muhammad Rauf Ahsan
- Section of Cardiac Surgery, Department of Cardiac Sciences, Libin Cardiovascular Institute, University of Calgary, AB, Canada
| |
Collapse
|
4
|
Kapadia SJ, Salmasi MY, Zientara A, Roussin I, Quarto C, Asimakopoulos G. Perceval sutureless bioprosthesis versus Perimount sutured bioprosthesis for aortic valve replacement in patients with aortic stenosis: a retrospective, propensity-matched study. J Cardiothorac Surg 2024; 19:95. [PMID: 38355617 PMCID: PMC10865583 DOI: 10.1186/s13019-024-02575-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Accepted: 01/30/2024] [Indexed: 02/16/2024] Open
Abstract
BACKGROUND Rapid-deployment aortic valve replacement (RDAVR) is an alternative to conventional AVR (cAVR) for aortic stenosis. Benefits include a reduction in operative times, facilitation of minimal access surgery and superior haemodynamics compared to conventional valves. However, further evidence is required to inform guidelines, preferably in the form of propensity-matched studies that include mid-term follow-up data. METHODS This was a single-centre, retrospective, propensity-matched cohort study comparing the Perceval and conventional Perimount Magna Ease valve for short- and mid-term clinical parameters and size-matched mid-term echocardiographic parameters (n = 102 in both groups) from 2014 to 2020. Data were extracted from a nationally managed dataset. RESULTS There were no demographic differences between the matched groups. The Perceval group had shorter cross-clamp time (Perceval 62 [49-81] minutes; Perimount 79 [63-102] minutes, P < 0.001), shorter bypass time (Perceval 89 [74-114] minutes; Perimount 104 [84-137] minutes, P < 0.001), and more frequent minimally-invasive approaches (Perceval 28%; Perimount 5%, P < 0.001). Size-matched haemodynamics showed initially higher gradients in the Perceval group, but haemodynamics equalised at 12 + months. The Perceval group had a more favourable % change in the left ventricular posterior wall dimension at 2 + years (Perceval - 4.8 ± 18; Perimount 17 ± 2). CONCLUSIONS The Perceval facilitated shorter operations, which may benefit intermediate-high-risk, elderly patients with comorbidities requiring concomitant procedures. It also facilitated minimally invasive surgery. Size-matched haemodynamic performance was similar at mid-term follow-up, with the Perceval possibly better facilitating regression of left ventricular hypertrophy.
Collapse
Affiliation(s)
- Sharan J Kapadia
- Imperial College School of Medicine, Exhibition Rd, South Kensington, London, SW7 2BX, UK.
| | - Mohammed Yousuf Salmasi
- Imperial College School of Medicine, Exhibition Rd, South Kensington, London, SW7 2BX, UK
- Department of Cardiothoracic Surgery, Royal Brompton and Harefield NHS Foundation Trust, Sydney Street, London, SW3 6NP, UK
| | - Alicja Zientara
- Department for Cardiac and Vascular Surgery, University of Freiburg, Hugstetter Strasse 55, 79106, Freiburg, Germany
| | - Isabelle Roussin
- Department of Cardiology, Lister Hospital East and North Hertfordshire NHS Trust, Coreys Mill Ln, Stevenage, SG1 4AB, UK
| | - Cesare Quarto
- Department of Cardiothoracic Surgery, Royal Brompton and Harefield NHS Foundation Trust, Sydney Street, London, SW3 6NP, UK
| | - George Asimakopoulos
- Department of Cardiothoracic Surgery, Royal Brompton and Harefield NHS Foundation Trust, Sydney Street, London, SW3 6NP, UK
| |
Collapse
|
5
|
Alaklabi AM, Abdul Rab S, Sabbah BN, Maklad AE, Dokollari A, Van den Eynde J, Pompeu Sa M, Arjomandi Rad A, Ahsan MR, Fatehi Hassanabad A. Innovations in Aortic Valve Replacement: A Comprehensive Overview of the Intuity Rapid Deployment Valve. Cardiol Rev 2024:00045415-990000000-00210. [PMID: 38334371 DOI: 10.1097/crd.0000000000000657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/10/2024]
Abstract
Rapid deployment/sutureless (RDS) valves have recently emerged as an innovative surgical solution, providing an alternative to traditional methods of surgical aortic valve replacement (SAVR) by eliminating the need for suture placement and tying. This innovation leads to a reduction in aortic crossclamp and cardiopulmonary bypass times, enhancing the efficiency of the procedure. Among the 2 available RDS valves, the Edwards Intuity valve in particular has been demonstrated to be a particularly promising substitute in the field of SAVR. The Intuity valve distinguishes itself from other RDS and conventional valves by yielding superior outcomes, such as a significant reduction in mortality, increase in the longevity of the valve, and a marked decrease in both mean and peak transvalvular pressure gradients. These benefits collectively contribute to its appeal as a favorable new solution. However, further investigation is needed to conclusively determine the long-term outcomes and safety of RDS valves. Nevertheless, the utilization of the Intuity valve presents an exciting solution to the existing limitations of conventional and minimally invasive SAVR, especially for patients afflicted with severe aortic stenosis.
Collapse
Affiliation(s)
| | - Saleha Abdul Rab
- From the College of Medicine, Alfaisal University, Riyadh, Saudi Arabia
| | - Belal N Sabbah
- From the College of Medicine, Alfaisal University, Riyadh, Saudi Arabia
| | | | - Aleksander Dokollari
- Section of Cardiac Surgery, St. Boniface Hospital, University of Manitoba, Winnipeg, Manitoba, Canada
| | | | - Michel Pompeu Sa
- Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, PA
- UPMC Heart and Vascular Institute, Pittsburgh, PA
| | | | - Muhammad Rauf Ahsan
- Section of Cardiac Surgery, Department of Cardiac Sciences, Libin Cardiovascular Institute, University of Calgary, Calgary, Canada
| | - Ali Fatehi Hassanabad
- Section of Cardiac Surgery, Department of Cardiac Sciences, Libin Cardiovascular Institute, University of Calgary, Calgary, Canada
| |
Collapse
|
6
|
Cummings I, Salmasi MY, Bulut HI, Zientara A, AlShiekh M, Asimakopoulos G. Sutureless Biological Aortic Valve Replacement (Su-AVR) in Redo operations: a retrospective real-world experience report of clinical and echocardiographic outcomes. BMC Cardiovasc Disord 2024; 24:28. [PMID: 38172707 PMCID: PMC10765636 DOI: 10.1186/s12872-023-03652-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2023] [Accepted: 12/03/2023] [Indexed: 01/05/2024] Open
Abstract
OBJECTIVE This retrospective study aimed to compare the outcomes of sutureless aortic valve replacement (su-AVR) and conventional bioprosthetic sutured AVR (cAVR) in high-risk patients undergoing redo surgery. METHODS A total of 79 patients who underwent redo AVR between 2014 and 2021 were included in the study. Of these, 27 patients underwent su-AVR and 52 underwent cAVR. Patient characteristics and clinical outcomes were analysed using multivariate regression and Kaplan Meier survival test. RESULTS The groups were similar in terms of age, gender, left ventricular function, and number of previous sternotomies. In cases of isolated AVR, su-AVR had significantly lower cross clamp times than cAVR (71 vs. 86 min, p = 0.03). Postoperatively, 4 cAVR patients required pacemaker compared to zero patients in the su-AVR group. There were no significant differences between the two groups in terms of postoperative complications, intrahospital stay (median 9 days, IQR 7-20), or in-hospital mortality (1 su-AVR; 2 cAVR). The long-term survival rate was similar between the su-AVR (90%) and cAVR (92%) groups (log rank p = 0.8). The transvalvular gradients at follow-up were not affected by the type of valve used, regardless of the valve size (coef 2.68, 95%CI -3.14-8.50, p = 0.36). CONCLUSION The study suggests that su-AVR is a feasible and safe alternative to cAVR in high-risk patients undergoing redo surgery. The use of su-AVR offers comparable outcomes to cAVR, with reduced cross clamp times and a lower incidence of postoperative pacemaker requirement in isolated AVR cases. The results of this study contribute to the growing body of evidence supporting the use of su-AVR in high-risk patients, highlighting its feasibility and safety in redo surgeries.
Collapse
Affiliation(s)
- Ian Cummings
- Department of Cardiac Surgery, St Thomas Hospital, London, UK
| | - M Yousuf Salmasi
- Department of Surgery, Imperial College London, QEQM Building, South Wharf Road, London, UK.
| | - Halil Ibrahim Bulut
- Department of Cardiothoracic Surgery, Royal Brompton and Harefield NHS Foundation Trust, London, UK
| | - Alicja Zientara
- Department of Cardiothoracic Surgery, Royal Brompton and Harefield NHS Foundation Trust, London, UK
| | - Mahmoud AlShiekh
- Department of Cardiothoracic Surgery, Royal Brompton and Harefield NHS Foundation Trust, London, UK
| | - George Asimakopoulos
- Department of Cardiothoracic Surgery, Royal Brompton and Harefield NHS Foundation Trust, London, UK
| |
Collapse
|
7
|
Sakata T, De La Pena C, Ohira S. Rapid-Deployment Aortic Valve Replacement: Patient Selection and Special Considerations. Vasc Health Risk Manag 2023; 19:169-180. [PMID: 37016696 PMCID: PMC10066891 DOI: 10.2147/vhrm.s374410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Accepted: 03/07/2023] [Indexed: 03/30/2023] Open
Abstract
Sutureless or rapid deployment valves in the setting of aortic valve replacement (AVR) is an emerging surgical technique using the transcatheter valve technology, which may lead to reduction in cross-clamp time and potentially better hemodynamics compared to a stented bioprosthetic valve. The absence of subannular pledgets results to excellent hemodynamic performance with reduced turbulent flow and larger effective orifice area. However, complications from both surgical and transcatheter AVR may still occur and impact survival. The incidence of paravalvular leakage and permanent pacemaker implantation are not low. Although technical modifications can improve these outcomes, there is a learning curve effect. Therefore, technical and anatomical considerations as well as better patient selection are paramount for better outcomes. In this review, we discuss the use of sutureless or rapid deployment valves in setting of (1) complex procedures, (2) minimally invasive AVR, and (3) small aortic annulus. The advantage of sutureless or rapid deployment valves in terms of mortality remains to be clarified; therefore, it is necessary to accumulate long-term outcomes in an appropriate patient cohort.
Collapse
Affiliation(s)
- Tomoki Sakata
- Cardiovascular Research Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Corazon De La Pena
- Department of Surgery, Division of Cardiothoracic Surgery, Westchester Medical Center, New York Medical College, Valhalla, NY, USA
| | - Suguru Ohira
- Department of Surgery, Division of Cardiothoracic Surgery, Westchester Medical Center, New York Medical College, Valhalla, NY, USA
- Correspondence: Suguru Ohira, Department of Surgery, Division of Cardiothoracic Surgery, Westchester Medical Center, New York Medical College, 100 Woods Road, Macy Pavilion, Valhalla, NY, 10595, USA, Tel +1 404 234 5433, Email
| |
Collapse
|
8
|
Ohira S, Pena CDL. The role of sutureless or rapid-deployment aortic valve prosthesis in bicuspid aortic valve: Standard AVR, TAVR, or somewhere in between? J Card Surg 2022; 37:3363-3364. [PMID: 35904124 DOI: 10.1111/jocs.16802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Accepted: 07/09/2022] [Indexed: 11/29/2022]
Affiliation(s)
- Suguru Ohira
- Department of Surgery, Division of Cardiothoracic Surgery, Westchester Medical Center, New York Medical College, Valhalla, New York, USA
| | - Corazon De La Pena
- Department of Surgery, Division of Cardiothoracic Surgery, Westchester Medical Center, New York Medical College, Valhalla, New York, USA
| |
Collapse
|