1
|
Papenfuß GS, König IR, Hagen C, Frydrychowicz A, Zell F, Ibbeken AJ, Buzug TM, Kirstein U, Kreft L, Grünberg D, Hakim S, Steffen A. Mandibular device treatment in obstructive sleep apnea -A structured therapy adjustment considering night-to-night variability night-to-night variability in mandibular devices. Sleep Breath 2024:10.1007/s11325-024-03134-w. [PMID: 39240485 DOI: 10.1007/s11325-024-03134-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Revised: 07/22/2024] [Accepted: 08/05/2024] [Indexed: 09/07/2024]
Abstract
BACKGROUND Mandibular advancement devices (MAD) are a well-established treatment option for obstructive sleep apnea (OSA). MAD are considered preferably for patients with mild to moderate OSA presenting with a elevated night-to-night variability (NNV). This study aimed to determine the treatment effect of MAD on NNV considering different protrusion distances and patient related outcome (PRO). METHODS We conducted a prospective cohort analysis of patients before MAD with 60% and 80% of the maximum protrusion. OSA severity was assessed using a home-sleep test for two consecutive nights. PRO contained the Epworth Sleepiness Scale (ESS) and sleep related quality of life (FOSQ). RESULTS Twenty patients with a median overweight body-mass-index of 27.1 (interquartile range (IQR) 16.3 kg/m²), with a mainly mild to moderate OSA with an apnea -hypopnea index (AHI) of 18.3 / h (IQR 17.7) and elevated ESS of 12.5 (IQR 8.0) were included. As opposed to 80%, 60% protrusion significantly but not 80% relevantly reduced AHI (60%%: 11.2 (IQR 5.5)/h, p = 0.01; 80%: 12.9 (IQR18,0)/h, p = 0.32) and improved the ESS (60%: 8.0 (IQR 10,0); 80%: 10 (IQR 9.0)), with therapy settings. No correlation could be detected between NNV and ESS, and FOSQ changes. Higher baseline NNV was associated with severe OSA (p = 0.02) but not with gender, overweight, or status post-tonsillectomy. CONCLUSIONS OSA improvement is associated with lower NNV; both OSA and NNV are connected to the degree of protrusion. Therefore, higher NNV does not justify the exclusion of candidates for MAD treatment. PRO changes are not visibly affected by NNV but by general OSA changes. These findings may help to define and optimize future study designs for the primary outcome decision between objective OSA parameters and PRO.
Collapse
Affiliation(s)
- Greta Sophie Papenfuß
- Department of Otorhinolaryngology, University of Lübeck, Campus Lübeck, Ratzeburger Allee 160, 23538, Lübeck, Germany
| | - Inke R König
- Institute of Medical Biometry and Statistics, University of Lübeck, Lübeck, Germany
| | - Christina Hagen
- Fraunhofer Research Institution for Individualized and Cell-Based Medical Engineering IMTE, Lübeck, Germany
| | - Alex Frydrychowicz
- Department of Radiology, University of Schleswig-Holstein, Campus Lübeck, Germany
| | - Fenja Zell
- Institute of Medical Engineering, University of Lübeck, Lübeck, Germany
| | | | - Thorsten M Buzug
- Fraunhofer Research Institution for Individualized and Cell-Based Medical Engineering IMTE, Lübeck, Germany
- Institute of Medical Engineering, University of Lübeck, Lübeck, Germany
| | - Ulrike Kirstein
- Department of Radiology, University of Schleswig-Holstein, Campus Lübeck, Germany
| | - Lina Kreft
- HICAT GmbH, SICAT GmbH & Co. KG, Bonn, Germany
| | | | - Samer Hakim
- Department of Oral and Maxillofacial Surgery, University of Lübeck, Lübeck, Germany
- Department of Oral and Maxillofacial Surgery, Helios Medical Centre, Schwerin, Germany
| | - Armin Steffen
- Department of Otorhinolaryngology, University of Lübeck, Campus Lübeck, Ratzeburger Allee 160, 23538, Lübeck, Germany.
| |
Collapse
|
2
|
Ng ET, Perez-Garcia A, Lagravère-Vich MO. Development and initial validation of a questionnaire to measure patient experience with oral appliance therapy. J Clin Sleep Med 2023; 19:1437-1445. [PMID: 37082817 PMCID: PMC10394373 DOI: 10.5664/jcsm.10562] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 03/22/2023] [Accepted: 03/23/2023] [Indexed: 04/22/2023]
Abstract
STUDY OBJECTIVES To develop and validate a questionnaire to measure patient experience with oral appliance therapy. METHODS The AMEE Guide No. 87 was followed in the development and validation of a patient questionnaire to assess patient experience with oral appliance therapy. RESULTS Our search identified 522 articles; 5 of these articles described the use and/or validation of questionnaires to measure changes in symptoms and patient-reported outcomes in the treatment of obstructive sleep apnea. A total of 27 questions were developed. Five patients participated in pilot testing. A final review of the questionnaire was conducted by an expert panel. CONCLUSIONS The creation and validation of a questionnaire to assess patient experience with oral appliance therapy may provide new methods for advancing research in the field of dental sleep medicine. CITATION Ng ET, Perez-Garcia A, Lagravère-Vich MO. Development and initial validation of a questionnaire to measure patient experience with oral appliance therapy. J Clin Sleep Med. 2023;19(8):1437-1445.
Collapse
Affiliation(s)
- Enoch T. Ng
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | - Arnaldo Perez-Garcia
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | - Manuel O. Lagravère-Vich
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
3
|
Fagundes NCF, Minervini G, Furio Alonso B, Nucci L, Grassia V, d'Apuzzo F, Puigdollers A, Perillo L, Flores-Mir C. PATIENT-REPORTED OUTCOMES WHILE MANAGING OBSTRUCTIVE SLEEP APNEA WITH ORAL APPLIANCES: A SCOPING REVIEW. J Evid Based Dent Pract 2023; 23:101786. [PMID: 36707161 DOI: 10.1016/j.jebdp.2022.101786] [Citation(s) in RCA: 29] [Impact Index Per Article: 29.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2022] [Revised: 08/21/2022] [Accepted: 09/14/2022] [Indexed: 11/05/2022]
Abstract
OBJECTIVE This scoping review aims to describe dental treatment-related patient-reported outcomes (dPROs) while using oral appliances (OAs) to manage obstructive sleep apnea (OSA) in children and adults. METHODS Available literature that assessed dPROs in children and adults with OSA managed through OAs. Any clinical studies were included without restrictions of year or country. The results were analyzed and reported using narrative text and tables accompanying a descriptive summary. RESULTS The searches identified 1718 citations, and of these, forty-five studies were finally included. A total of 3498 adults were included in all 42 primary studies included in this review, in which all the studies presented adults as participants. The dPROs assessed were quality of life (QoL), reported side effects after OA usage, patient satisfaction, and experience with treatment, and subjective perception of occlusal changes after treatment. CONCLUSION This scoping review suggests that dPROs are mostly investigated as a secondary outcome from major studies exploring the effects of OAs on OSA severity, and often, dPROs are not well discussed or displayed on their report. As no risk of bias or certainty level assessment was completed, findings need to be carefully considered. Although in general terms management with OAs among adults with OSA does not seem to be uncomfortable or causing major problems to their lives, some mild discomfort and endured occlusal disturbances was reported in some studies. QoL seems to improve but consistent agreement was elusive. Data does not include experiences among those that dropped OA use. No data seems to exist about dPROs in children.
Collapse
Affiliation(s)
| | - Giuseppe Minervini
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, Orthodontic Program, University of Campania Luigi Vanvitelli, Naples, Italy
| | - Berta Furio Alonso
- Department of Orthodontics and Craniofacial Orthopedics, Universitat Internacional de Catalunya, Barcelona, Spain
| | - Ludovica Nucci
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, Orthodontic Program, University of Campania Luigi Vanvitelli, Naples, Italy
| | - Vincenzo Grassia
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, Orthodontic Program, University of Campania Luigi Vanvitelli, Naples, Italy
| | - Fabrizia d'Apuzzo
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, Orthodontic Program, University of Campania Luigi Vanvitelli, Naples, Italy
| | - Andreu Puigdollers
- Department of Orthodontics and Craniofacial Orthopedics, Universitat Internacional de Catalunya, Barcelona, Spain
| | - Letizia Perillo
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, Orthodontic Program, University of Campania Luigi Vanvitelli, Naples, Italy
| | - Carlos Flores-Mir
- School of Dentistry, Faculty of Medicine and Dentistry, College of Health Sciences, University of Alberta, Edmonton, Alberta, Canada.
| |
Collapse
|
4
|
Berggren K, Broström A, Firestone A, Wright B, Josefsson E, Lindmark U. Oral health problems linked to obstructive sleep apnea are not always recognized within dental care-As described by dental professionals. Clin Exp Dent Res 2021; 8:84-95. [PMID: 34791818 PMCID: PMC8874038 DOI: 10.1002/cre2.517] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 10/18/2021] [Accepted: 10/27/2021] [Indexed: 11/27/2022] Open
Abstract
Objectives Obstructive sleep apnea (OSA) has an impact on an individual's quality of life and general health, and can also affect their oral health. The patient's experiences, together with intraoral signs and symptoms could indicate the presence of OSA. Knowledge that the patient has, or is at high risk for having OSA can help the dental healthcare provider maintain the oral health and general health for these patients. The purpose was to explore dentists and dental hygienists' experiences when encountering adult patients with potential, untreated and treated OSA. Methods A qualitative inductive approach was used. Experienced dentists and dental hygienists working within Swedish Public Dental Service were strategically selected. Semi‐structured face‐to‐face interviews were performed followed by qualitative content analysis. Results Interviews from 13 participants, seven dental hygienist and six dentists, led to three areas describing varied experience: Importance of the patient encounter and identifying intraoral signs both of which describe experiences related to the importance of the initial unstructured conversation and focused clinical assessments, and strategies for nurturing care which point to interest about care, treatment, and collaborations with medical health care providers. Conclusions Dental professionals are not able to consistently recognize patients who have, or are at high risk for OSA. During the patient encounter, is it important to determine if a patient is at risk for, or has oral signs of OSA.
Collapse
Affiliation(s)
- Kristina Berggren
- Center of Oral Health, School of Health and Welfare, Jönköping University, Jönköping, Sweden
| | - Anders Broström
- Department of Nursing, School of Health and Welfare, Jönköping University, Jönköping, Sweden.,Department of Clinical Neurophysiology, Linköping University Hospital, Linköping, Sweden
| | - Allen Firestone
- Division of Orthodontics, Ohio State University, Columbus, Ohio, USA
| | - Bridget Wright
- Division of Dental Hygiene, Ohio State University, Columbus, Ohio, USA
| | - Eva Josefsson
- Odontologiska Institutionen, Department of Orthodontics, Jönköping, Sweden
| | - Ulrika Lindmark
- Center of Oral Health, School of Health and Welfare, Jönköping University, Jönköping, Sweden.,Division of Dental Hygiene, Ohio State University, Columbus, Ohio, USA.,Department of Health Sciences, Karlstad University, Karlstad, Sweden
| |
Collapse
|
5
|
Gjerde K, Lehmann S, Bjorvatn B, Berge M, Thuen F, Berge T, Johansson A. Partner perceptions are associated with objective sensor-measured adherence to oral appliance therapy in obstructive sleep apnea. J Sleep Res 2021; 31:e13462. [PMID: 34490690 DOI: 10.1111/jsr.13462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 07/19/2021] [Accepted: 07/27/2021] [Indexed: 11/28/2022]
Abstract
The aims of the present prospective clinical study were to determine objective, sensor-measured adherence to a mandibular advancement device (MAD) in patients with obstructive sleep apnea (OSA) and to identify partner-specific adherence-related factors. A total of 77 eligible participants with mild, moderate, or severe OSA and who were non-adherent to continuous positive airway pressure (mean age 56.2 years) participated in the study (32.5% women). The mean (range) observation time between MAD delivery and final follow-up was 8.3 (3.4-16.5) months. The mean apnea-hypopnea index (AHI) was 26.6 events/hr at baseline and 12.5 events/hr at the 8-month follow-up (both p < 0.001). The mean sensor-measured adherence at the 8-month follow-up was 60.1% for ≥4 hr/night of appliance use for ≥5 days/week. Average usage was 6.4 hr/night, when worn. The mean reduction in the AHI was significantly greater in the "good adherence" (Δ 17.4) than the "poor adherence" group (Δ11.0; p < 0.05). From the partner's perspective, the appliance had a positive effect on sharing a bedroom in the good- (55%) compared to the poor-adherence group (25%; p < 0.05) and on their relationship (51.7% versus 17.9%, respectively; p < 0.05). Regression analyses identified the partner's snoring and apneas to be the most significant factor predicting good adherence to MAD (odds ratio 4.4, 95% confidence interval 1.4-14.0). In conclusion, social factors, like partner perceptions, were positively associated with adherence, which indicate that partner's attitudes and support may be a resource that can be utilised to improve adherence in oral appliance treatment of OSA.
Collapse
Affiliation(s)
- Kjersti Gjerde
- Department of Clinical Dentistry - Prosthodontics, Faculty of Medicine, University of Bergen, Bergen, Norway.,Department of Thoracic Medicine, Centre for Sleep Medicine, Haukeland University Hospital, Bergen, Norway
| | - Sverre Lehmann
- Department of Thoracic Medicine, Centre for Sleep Medicine, Haukeland University Hospital, Bergen, Norway.,Section for Thoracic Medicine, Department of Clinical Science, Faculty of Medicine, University of Bergen, Bergen, Norway.,Norwegian Competence Center for Sleep Disorders, Haukeland University Hospital, Bergen, Norway
| | - Bjørn Bjorvatn
- Department of Thoracic Medicine, Centre for Sleep Medicine, Haukeland University Hospital, Bergen, Norway.,Norwegian Competence Center for Sleep Disorders, Haukeland University Hospital, Bergen, Norway.,Department of Global Public Health and Primary Care, Faculty of Medicine, University of Bergen, Berge, Norway
| | - Morten Berge
- Department of Clinical Dentistry - Prosthodontics, Faculty of Medicine, University of Bergen, Bergen, Norway.,Department of Thoracic Medicine, Centre for Sleep Medicine, Haukeland University Hospital, Bergen, Norway
| | - Frode Thuen
- Department of Welfare and Participation, Western Norway University of Applied Sciences, Bergen, Norway
| | - Thomas Berge
- Department of Thoracic Medicine, Centre for Sleep Medicine, Haukeland University Hospital, Bergen, Norway
| | - Anders Johansson
- Department of Clinical Dentistry - Prosthodontics, Faculty of Medicine, University of Bergen, Bergen, Norway.,Department of Thoracic Medicine, Centre for Sleep Medicine, Haukeland University Hospital, Bergen, Norway
| |
Collapse
|
6
|
[Oral appliances for obstructive sleep apnoea: What can we expect?]. Rev Mal Respir 2020; 37:526-549. [PMID: 32636050 DOI: 10.1016/j.rmr.2020.06.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Accepted: 04/28/2020] [Indexed: 01/01/2023]
Abstract
INTRODUCTION Mandibular appliances are a treatment option for obstructive sleep apnea. There are many designs, but in the literature they tend to be grouped into a single entity without considering that efficiency, tolerance, compliance, or side effects are inherent in the design of each of them. A more detailed literature review is therefore warranted for the reader who wants to understand the relative effectiveness of each appliance. STATE OF KNOWLEDGE We conducted a literature search using the "oral appliance" and "obstructive sleep apnea" criteria on Pubmed, Embase and Cochrane. This allowed us to compare outcome parameters by appliance class and to highlight the rare studies comparing different appliances. CONCLUSIONS Mandibular appliances are not a homogeneous entity. Common use includes only appliances designed for propulsion (with rods and jacks) and retention. However, the few comparative studies available do not identify which are the most effective types or the types with an optimal efficacy/tolerance ratio. PERSPECTIVES Further appliance comparison studies are needed to determine the most effective type or with an optimal efficacy/tolerance ratio.
Collapse
|
7
|
Saglam-Aydinatay B, Taner T. Oral appliance therapy in obstructive sleep apnea: Long-term adherence and patients experiences. Med Oral Patol Oral Cir Bucal 2018; 23:e72-e77. [PMID: 29274155 PMCID: PMC5822544 DOI: 10.4317/medoral.22158] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2017] [Accepted: 10/10/2017] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND Despite the advances in the treatment of obstructive sleep apnea (OSA) with mandibular advancement appliances (MAA), their effectiveness is dependent on the patients compliance. Our aims were to evaluate the long-term adherence to MAA therapy and patients experiences of the treatment in OSA. MATERIAL AND METHODS Sixty-nine patients (52 males, 17 females; Mean age: 54.4±10.8 years) were included in the study. The subjects were mild (56%) and moderate (44%) OSA patients who had been treated using MAA at least 4 years prior to the study. A phone survey was used to determine the demographic characteristics of the patients, as well as to assess self-reported adherence to therapy, subjective long-term effectiveness, and patient experiences with the appliance. Descriptive statistics, Pearson Chi-square test, and independent samples t-test were used for data analysis. RESULTS Only 22 (32%) patients reported using the appliance regularly. Most of the non-adherent patients had stopped using their appliances in the first year (55%). The mean duration of appliance use was 33.5 months (Median: 12 months). No significant differences in appliance type, OSA severity, educational level, gender, marital status, income status, employment status or place of residence existed between adherent and non-adherent subjects. Adherent subjects were significantly younger than non-adherent subjects (Age: 50.6 ± 11.9 versus 56.1 ± 9.9, p < 0.05). The most common reasons reported by patients were inability to adapt to the appliance (62%) and pain in the temporomandibular joint (38%). The most common factors associated with continued usage were effectiveness (100%) and ease of use (64%). CONCLUSIONS The overall long-term nonadherence to MAA therapy in mild-to moderate OSA patients was high suggesting that barriers to MAA therapy adherence should be prevented to increase the efficiency of oral appliance treatment in OSA and achieve better outcomes for this disease.
Collapse
Affiliation(s)
- B Saglam-Aydinatay
- Department of Orthodontics, Faculty of Dentistry, Hacettepe University, Sihhiye, Ankara 06100, Turkey,
| | | |
Collapse
|