1
|
Niyazmand H, Alam K, Charng J, Woodman-Pieterse EC, Read SA, Vincent SJ, Hughes RPJ. The effect of near work on the anterior eye and associations with myopia: a narrative review. Clin Exp Optom 2025:1-14. [PMID: 40037611 DOI: 10.1080/08164622.2025.2468900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Revised: 02/12/2025] [Accepted: 02/13/2025] [Indexed: 03/06/2025] Open
Abstract
The global prevalence of myopia has increased significantly in recent decades, and it is anticipated that half the population of the world will be myopic by 2050. The dramatic increase in myopia cannot be explained solely by genetic factors; hence, environmental factors such as near work may play an important role in myopia development. Near work activities involve accommodation, convergence, and pupil constriction, which lead to various mechanical changes that alter the structural and optical properties of the anterior eye. Mechanical changes associated with near work activities include ciliary body contraction, medial rectus contraction, lateral rectus relaxation, changes in the eyelid-cornea interaction, pupil size, and crystalline lens shape and position. These structural variations lead to optical changes including a change in spherical refractive power, astigmatism, accommodative convergence, higher order aberrations, and retinal image quality. Several differences in near work-related optical and structural changes have been observed between myopes and non-myopes. These differences elucidate mechanisms that potentially underpin near work-associated axial elongation and myopia development. This narrative review explores anterior segment structural and optical changes during near work and their potential mechanistic contribution to myopia development, while highlighting literature gaps that require further research.
Collapse
Affiliation(s)
- Hamed Niyazmand
- Department of Optometry and Vision Sciences, The University of Western Australia, Perth, Australia
| | - Khyber Alam
- Department of Optometry and Vision Sciences, The University of Western Australia, Perth, Australia
| | - Jason Charng
- Department of Optometry and Vision Sciences, The University of Western Australia, Perth, Australia
- Centre of Ophthalmology and Visual Science (incorporating Lions Eye Institute), The University of Western Australia, Western Australia, Australia
| | | | - Scott A Read
- Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Australia
| | - Stephen J Vincent
- Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Australia
| | - Rohan P J Hughes
- Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Australia
| |
Collapse
|
2
|
Zhuang CC, Zhang L, Pan SS, Wang YN, Guo JX. Accommodation and Binocular Vision in Children with Myopic Anisometropia. J Ophthalmol 2024; 2024:6525136. [PMID: 38264273 PMCID: PMC10805551 DOI: 10.1155/2024/6525136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Revised: 01/02/2024] [Accepted: 01/04/2024] [Indexed: 01/25/2024] Open
Abstract
Purpose To assess the differences in accommodation and binocular vision in children with myopic anisometropia and determine the correlation with anisometropia. Method A total of 110 patients with myopia aged 8-15 years were recruited from June 2021 to February 2022 from the Affiliated Hospital of Xuzhou Medical University. Based on the interocular differences of spherical equivalent refraction, patients were divided into the isometropia (35 children), low anisometropia (LA group, 42 children), and high anisometropia (HA group, 33 children). The variables assessed were refraction, heterophoria, amplitude of accommodation (AMP), accommodative response (AR), gradient AC/A, positive and negative relative accommodation (PRA/NRA), and near stereopsis in the three groups. Pearson's correlation coefficient tests were used to investigate the possible association between each parameter and interocular differences (IODs). Results Among 110 subjects, there were 49 males and 61 females with a mean age of 11.39 ± 2.28 years. Compared with those in the isometropia group, AMP was lower and near stereopsis was higher in the LA group, and the distance and near heterophoria, PRA, AR, and near stereopsis were higher, and PRA, AMP, and gradient AC/A were lower in the HA group (all P < 0.05). Compared with those in the LA group, the near stereopsis, AR, and the near stereopsis were higher in the HA group, and the gradient AC/A was lower (all P < 0.05). However, no significant differences existed in the negative relative accommodation (P > 0.05). The distance and near heterophoria, AR, AMP, and near stereopsis were observed to be correlated with IODs, respectively (r = -0.259, p = 0.006; r = -0.201, p = 0.036; r = 0.306, p = 0.001; r = -0.315, p = 0.001; r = 0.535, p < 0.001). Conclusion Our results suggested that with the increase of anisometropia, distance and near heterophoria, AR, AMP, and near stereopsis had a tendency to get worse in children with myopic anisometropia.
Collapse
Affiliation(s)
- Chu-chu Zhuang
- The First Medicine College, Xuzhou Medical University, Xuzhou 221004, China
| | - Ling Zhang
- The First Medicine College, Xuzhou Medical University, Xuzhou 221004, China
| | - Shan-shan Pan
- Department of Ophthalmology, Affiliated Hospital of Xuzhou Medical University, Xuzhou 221004, China
| | - Yi-ning Wang
- The First Medicine College, Xuzhou Medical University, Xuzhou 221004, China
| | - Jian-xin Guo
- Department of Ophthalmology, Affiliated Hospital of Xuzhou Medical University, Xuzhou 221004, China
| |
Collapse
|
3
|
Cabeza-Gil I, Fabrice M, Begoña C, Marco R. Quantification of scleral changes during dynamic accommodation. Exp Eye Res 2023; 230:109441. [PMID: 36958428 DOI: 10.1016/j.exer.2023.109441] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Revised: 01/11/2023] [Accepted: 03/16/2023] [Indexed: 03/25/2023]
Abstract
The mechanics of accommodation is a complex process that involves multiple intraocular ocular structures. Recent studies suggest that there is deformation of the sclera during accommodation that may also play a role in accommodation, influencing ciliary muscle contraction and contributing to the accommodative response. However, the type and magnitude of the deformations measured varies significantly across studies. We present high-resolution synchronous OCT measurements of the anterior sclera contour and thickness and lens thickness acquired in real-time during accommodative responses to 4D step stimuli. The lens thickness was used as an assessment of objective accommodation. No changes in nasal and temporal anterior scleral contour and scleral thickness were found during accommodation within the precision of our measurements. Our results demonstrate that there are no significant scleral deformations during accommodation.
Collapse
Affiliation(s)
- Iulen Cabeza-Gil
- Aragón Institute of Engineering Research (i3A), University of Zaragoza, Spain.
| | - Manns Fabrice
- Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA; Department of Biomedical Engineering, University of Miami College of Engineering, Coral Gables, FL, USA
| | - Calvo Begoña
- Aragón Institute of Engineering Research (i3A), University of Zaragoza, Spain; Bioengineering, Biomaterials and Nanomedicine Networking Biomedical Research Centre (CIBER-BBN), Zaragoza, Spain
| | - Ruggeri Marco
- Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA; Department of Biomedical Engineering, University of Miami College of Engineering, Coral Gables, FL, USA.
| |
Collapse
|
4
|
Niyazmand H, Read SA, Atchison DA. Repeatability of Anterior Eye Surface Topography Parameters from an Anterior Eye Surface Profilometer. Optom Vis Sci 2021; 98:1203-1209. [PMID: 34620781 DOI: 10.1097/opx.0000000000001789] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
SIGNIFICANCE Anterior eye shape measurements are important for clinical contact lens fitting. The detailed assessment of measurement repeatability using the Eye Surface Profiler (ESP; Eaglet Eye B.V., AP Houten, the Netherlands) allows for more reliable interpretation of eye surface topography measurements. PURPOSE This study aimed to determine the repeatability of the ESP for anterior central corneal power and anterior eye surface height measurements. METHODS A Badal optometer was mounted on the ESP to provide an external fixation target with appropriate accommodation control and refractive correction. Forty-five healthy young adults underwent two sessions of anterior eye measurements, separated by 20 minutes, using the ESP. In each session, three consecutive scans were captured. Sagittal height data were obtained from 8-mm central cornea and from 8- to 14-mm diameter (encompassing the corneal periphery and anterior sclera). Anterior corneal powers were determined from the central cornea. Intersessional and intrasessional repeatability values were determined as coefficients of repeatability and root mean square error differences. RESULTS Sagittal height intersessional coefficients of repeatability for central nasal (5 μm) and central temporal (7 μm) were better than peripheral nasal (24 μm) and peripheral temporal (21 μm) regions. Sagittal height intrasessional coefficients of repeatability were 9, 8, 28, and 31 μm for central nasal, central temporal, peripheral nasal, and peripheral temporal regions, respectively. Intersessional coefficients of repeatability of mean sphere, 90/180° (J0) astigmatism, and oblique (J45) astigmatism were 0.67, 0.22, and 0.13 D, respectively, with corresponding intrasessional coefficients of repeatability of 1.27, 0.21, and 0.27 D. CONCLUSIONS The modified measuring procedure for the ESP used in this study provides highly repeatable sagittal height measurements in the central cornea but is less repeatable in the corneal periphery and scleral region. Results of the current study can be considered when using ESP in the interpretation of anterior eye surface shape measurements and in contact lens fitting and design.
Collapse
Affiliation(s)
| | - Scott A Read
- Contact Lens and Visual Optics Laboratory, Centre for Vision and Eye Research, School of Optometry and Vision Science, Kelvin Grove, Queensland University of Technology, Queensland, Australia
| | - David A Atchison
- Visual and Ophthalmic Optics Laboratory, Centre for Vision and Eye Research, School of Optometry and Vision Science, Kelvin Grove, Queensland University of Technology, Queensland, Australia
| |
Collapse
|
5
|
Logan NS, Radhakrishnan H, Cruickshank FE, Allen PM, Bandela PK, Davies LN, Hasebe S, Khanal S, Schmid KL, Vera-Diaz FA, Wolffsohn JS. IMI Accommodation and Binocular Vision in Myopia Development and Progression. Invest Ophthalmol Vis Sci 2021; 62:4. [PMID: 33909034 PMCID: PMC8083074 DOI: 10.1167/iovs.62.5.4] [Citation(s) in RCA: 67] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
The role of accommodation in myopia development and progression has been debated for decades. More recently, the understanding of the mechanisms involved in accommodation and the consequent alterations in ocular parameters has expanded. This International Myopia Institute white paper reviews the variations in ocular parameters that occur with accommodation and the mechanisms involved in accommodation and myopia development and progression. Convergence is synergistically linked with accommodation and the impact of this on myopia has also been critiqued. Specific topics reviewed included accommodation and myopia, role of spatial frequency, and contrast of the task of objects in the near environment, color cues to accommodation, lag of accommodation, accommodative-convergence ratio, and near phoria status. Aspects of retinal blur from the lag of accommodation, the impact of spatial frequency at near and a short working distance may all be implicated in myopia development and progression. The response of the ciliary body and its links with changes in the choroid remain to be explored. Further research is critical to understanding the factors underlying accommodative and binocular mechanisms for myopia development and its progression and to guide recommendations for targeted interventions to slow myopia progression.
Collapse
Affiliation(s)
- Nicola S Logan
- School of Optometry, Aston University, Birmingham, United Kingdom
| | - Hema Radhakrishnan
- Division of Pharmacy and Optometry, School of Health Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom
| | - Fiona E Cruickshank
- Division of Pharmacy and Optometry, School of Health Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom
| | - Peter M Allen
- Vision and Hearing Sciences Research Centre, School of Psychology and Sports Sciences, Anglia Ruskin University, Cambridge, United Kingdom
| | - Praveen K Bandela
- Brien Holden Vision Institute, Sydney, New South Wales, Australia.,School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | - Leon N Davies
- School of Optometry, Aston University, Birmingham, United Kingdom
| | - Satoshi Hasebe
- Department of Ophthalmology, Kawasaki Medical School, Kurashiki, Okayama, Japan
| | - Safal Khanal
- School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama, United States
| | - Katrina L Schmid
- School of Optometry and Vision Science, Queensland University of Technology, Brisbane, Australia
| | | | | |
Collapse
|
6
|
Barnett M, Courey C, Fadel D, Lee K, Michaud L, Montani G, van der Worp E, Vincent SJ, Walker M, Bilkhu P, Morgan PB. CLEAR - Scleral lenses. Cont Lens Anterior Eye 2021; 44:270-288. [PMID: 33775380 DOI: 10.1016/j.clae.2021.02.001] [Citation(s) in RCA: 56] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Accepted: 02/01/2021] [Indexed: 12/25/2022]
Abstract
Scleral lenses were the first type of contact lens, developed in the late nineteenth century to restore vision and protect the ocular surface. With the advent of rigid corneal lenses in the middle of the twentieth century and soft lenses in the 1970's, the use of scleral lenses diminished; in recent times there has been a resurgence in their use driven by advances in manufacturing and ocular imaging technology. Scleral lenses are often the only viable form of contact lens wear across a range of clinical indications and can potentially delay the need for corneal surgery. This report provides a brief historical review of scleral lenses and a detailed account of contemporary scleral lens practice including common indications and recommended terminology. Recent research on ocular surface shape is presented, in addition to a comprehensive account of modern scleral lens fitting and on-eye evaluation. A range of optical and physiological challenges associated with scleral lenses are presented, including options for the clinical management of a range of ocular conditions. Future applications which take advantage of the stability of scleral lenses are also discussed. In summary, this report presents evidence-based recommendations to optimise patient outcomes in modern scleral lens practice.
Collapse
Affiliation(s)
- Melissa Barnett
- University of California, Davis Eye Center, Sacramento, CA, United States.
| | | | | | - Karen Lee
- University of Houston, College of Optometry, Houston, TX, United States
| | | | - Giancarlo Montani
- Università del Salento, Dipartimento di Matematica e Fisica CERCA, Lecce, Italy
| | - Eef van der Worp
- Eye-Contact-Lens Research & Education, Amsterdam, NL, Netherlands
| | - Stephen J Vincent
- Queensland University of Technology (QUT), Centre for Vision and Eye Research, School of Optometry and Vision Science, Contact Lens and Visual Optics Laboratory, Brisbane, Australia
| | - Maria Walker
- University of Houston, College of Optometry, Houston, TX, United States
| | - Paramdeep Bilkhu
- School of Optometry & Vision Science, Aston University, Birmingham, United Kingdom
| | - Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, Manchester, United Kingdom
| |
Collapse
|
7
|
Relationship between Axial Length and Corneo-Scleral Topography: A Preliminary Study. Diagnostics (Basel) 2021; 11:diagnostics11030542. [PMID: 33803709 PMCID: PMC8002979 DOI: 10.3390/diagnostics11030542] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 03/12/2021] [Accepted: 03/16/2021] [Indexed: 11/17/2022] Open
Abstract
The main objective of the current study was to investigate further the relationship of the overall length of the eye with a great variety of anterior segment parameters, including scleral geometry. A total of 64 eyes of 32 participants with ages from 12 to 52 years were included in this prospective non-randomized single-center study. All participants underwent a complete eye examination, including an analysis of corneo-scleral shape with a Fourier-domain profilometer. A strong negative correlation was found between axial length and temporal-nasal ocular sagittal height difference for different chord lengths. For the right eye, a consistent and stable linear model was obtained to predict the axial length from the spherical equivalent, the corneal diameter, the high-order aberrations root mean square, and the minimum sagittal height for 13- and 14-mm chord. For the left eye, a model was obtained to predict the axial length from the spherical equivalent and the mean corneal curvature, including other parameters such as corneal diameter or high-order aberrations, depending on the chord length, considered for estimating the sagittal height values. More studies with larger samples are needed to confirm these preliminary outcomes.
Collapse
|
8
|
Niyazmand H, Read SA, Atchison DA, Alonso-Caneiro D, Collins MJ. Anterior scleral thickness and shape changes with different levels of simulated convergence. Exp Eye Res 2021; 203:108435. [PMID: 33421425 DOI: 10.1016/j.exer.2020.108435] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 11/29/2020] [Accepted: 12/30/2020] [Indexed: 12/14/2022]
Abstract
PURPOSE Convergence plays a fundamental role in the performance of near visual tasks. We measured the effect of two levels of convergence on anterior scleral thickness and shape in emmetropes, low to moderate myopes and high myopes. METHODS Forty-five healthy young adults aged between 18 and 35 years including 15 emmetropes, 15 low/moderate myopes, and 15 high myopes were recruited. Anterior segment optical coherence tomography and eye surface profilometry were used to evaluate the anterior scleral thickness (nasal only, n = 42) and shape (n = 40), before and during two visual tasks involving 9° and 18° convergence, in those participants with complete and reliable data. RESULTS Convergence led to a thickening of the total anterior eye wall (5.9 ± 1.4 μm) and forward movement (10 ± 2 μm) of the nasal anterior scleral surface (both p < 0.001). Larger changes were found at 18° than at 9° convergence and in more peripheral nasal scleral regions. There was a significant association between total wall thickening and forward movement of the scleral surface. Refractive group was not a significant main effect, but there were significant interactions between refractive group and the thickness changes with convergence in different scleral regions. CONCLUSION During convergence, the biomechanical forces acting on the eye lead to nasal anterior scleral thickening and forward movement of the nasal scleral surface.
Collapse
Affiliation(s)
- Hamed Niyazmand
- Contact Lens and Visual Optics Laboratory, Centre for Vision and Eye Research, School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, QLD, 4059, Australia.
| | - Scott A Read
- Contact Lens and Visual Optics Laboratory, Centre for Vision and Eye Research, School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, QLD, 4059, Australia.
| | - David A Atchison
- Visual and Ophthalmic Optics Laboratory, Centre for Vision and Eye Research, School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, QLD, 4059, Australia.
| | - David Alonso-Caneiro
- Contact Lens and Visual Optics Laboratory, Centre for Vision and Eye Research, School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, QLD, 4059, Australia.
| | - Michael J Collins
- Contact Lens and Visual Optics Laboratory, Centre for Vision and Eye Research, School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, QLD, 4059, Australia.
| |
Collapse
|