Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study. Neurospine 2024; 21:273-285. [PMID: 38317559 PMCID: PMC10992651 DOI: 10.14245/ns.2347076.538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2023] [Revised: 11/22/2023] [Accepted: 12/05/2023] [Indexed: 02/07/2024] Open
Abstract
OBJECTIVE This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines. METHODS Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud. RESULTS In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4-5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model. CONCLUSION In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
Collapse
|
2
|
The effect of polymethylmethacrylate augmentation on the primary stability of stand-alone implant construct versus posterior stabilization in oblique lumbar interbody fusion with osteoporotic bone quality- a finite element study. Spine J 2024:S1529-9430(24)00039-1. [PMID: 38307174 DOI: 10.1016/j.spinee.2024.01.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 01/26/2024] [Accepted: 01/27/2024] [Indexed: 02/04/2024]
Abstract
BACKGROUND CONTEXT Oblique lumbar interbody fusion (OLIF) can provide an ideal minimally invasive solution for achieving spinal fusion in an older, more frail population where decreased bone quality can be a limiting factor. Stabilization can be achieved with bilateral pedicle screws (BPS), which require additional incisions and longer operative time. Alternatively, a novel self-anchoring stand-alone lateral plate system (SSA) can be used, where no additional incisions are required. Based on the relevant literature, BPS constructs provide greater primary biomechanical stability compared to lateral plate constructs, including SSA. This difference is further increased by osteoporosis. Screw augmentation in spinal fusion surgeries is commonly used; however, in the case of OLIF, it is a fairly new concept, lacking a consensus-based guideline. PURPOSE This comparative finite element (FE) study aimed to investigate the effect of PMMA screw augmentation on the primary stability of a stand-alone implant construct versus posterior stabilization in OLIF with osteoporotic bone quality. STUDY DESIGN The biomechanical effect of screw augmentation was studied inside an in-silico environment using computer-aided FE analysis. METHODS A previously validated and published L2-L4 FE model with normal and osteoporotic bone material properties was used. Geometries based on the OLIF implants (BPS, SSA) were created and placed inside the L3-L4 motion segment with increasing volumes (1-6 cm3) of PMMA augmentation. A follower load of 400 N and 10 Nm bending moment (in the three anatomical planes) were applied to the surgical FE models with different bone material properties. The operated L3-L4 segmental range of motion (ROM), the inserted cage's maximal caudal displacements, and L4 cranial bony endplate principal stress values were measured. RESULTS The non-augmented values for the BPS construct were generally lower compared to SSA, and the difference was increased by osteoporosis. In osteoporotic bone, PMMA augmentation gradually decreased the investigated parameters and the difference between the two constructs as well. Between 3 cm3 and 4 cm3 of injected PMMA volume per screw, the difference between augmented SSA and standard BPS became comparable. CONCLUSIONS Based on this study, augmentation can enhance the primary stability of the constructs and decrease the difference between them. Considering leakage as a possible complication, between 3 cm3 and 4 cm3 of injected PMMA per screw can be an adequate amount for SSA augmentation. However, further in silico, and possibly in vitro and clinical testing is required to thoroughly understand the investigated biomechanical aspects. CLINICAL SIGNIFICANCE This study sheds light on the possible biomechanical advantage offered by augmented OLIF implants and provides a theoretical augmentation amount for the SSA construct. Based on the findings, the concept of an SSA device with PMMA augmentation capability is desirable.
Collapse
|
3
|
Biomechanical evaluation of different oblique lumbar interbody fusion constructs: a finite element analysis. BMC Musculoskelet Disord 2024; 25:97. [PMID: 38279094 PMCID: PMC10821608 DOI: 10.1186/s12891-024-07204-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Accepted: 01/14/2024] [Indexed: 01/28/2024] Open
Abstract
BACKGROUND Finite element analysis (FEA) was performed to investigate the biomechanical differences between different adjunct fixation methods for oblique lumbar interbody fusion (OLIF) and to further analyze its effect on adjacent segmental degeneration. METHODS We built a single-segment (Si-segment) finite element model (FEM) for L4-5 and a double-segment (Do-segment) FEM for L3-5. Each complete FEM was supplemented and modified, and both developed two surgical models of OLIF with assisted internal fixation. They were OLIF with posterior bilateral percutaneous pedicle screw (TINA system) fixation (OLIF + BPS) and OLIF with lateral plate system (OLIF + LPS). The range of motion (ROM) and displacement of the vertebral body, cage stress, adjacent segment disc stress, and spinal ligament tension were recorded for the four models during flexion/extension, right/left bending, and right/left rotation by applying follower load. RESULTS For the BPS and LPS systems in the six postures of flexion, extension, right/left bending, and right/left rotation, the ROM of L4 in the Si-segment FEM were 0.32°/1.83°, 0.33°/1.34°, 0.23°/0.47°, 0.24°/0.45°, 0.33°/0.79°, and 0.34°/0.62°; the ROM of L4 in the Do-segment FEM were 0.39°/2.00°, 0.37°/1.38°, 0.23°/0.47°, 0.21°/0.44°, 0.33°/0.57°, and 0.31°/0.62°, and the ROM of L3 in the Do-segment FEM were 6.03°/7.31°, 2.52°/3.50°, 4.21°/4.38°, 4.21°/4.42°, 2.09°/2.32°, and 2.07°/2.43°. BPS system had less vertebral displacement, less cage maximum stress, and less spinal ligament tension in Si/Do-segment FEM relative to the LPS system. BPS system had a smaller upper adjacent vertebral ROM, greater intervertebral disc stress in terms of left and right bending as well as left and right rotation compared to the LPS system in the L3-4 of the Do-segment FEM. There was little biomechanical difference between the same fixation system in the Si/Do-segment FEM. CONCLUSIONS Our finite element analysis showed that compared to OLIF + LPS, OLIF + BPS (TINA) is more effective in reducing interbody stress and spinal ligament tension, and it better maintains the stability of the target segment and provides a better fusion environment to resist cage subsidence. However, OLIF + BPS (TINA) may be more likely to cause adjacent segment degeneration than OLIF + LPS.
Collapse
|
4
|
Biomechanical differences between two different shapes of oblique lumbar interbody fusion cages on whether to add posterior internal fixation system: a finite element analysis. J Orthop Surg Res 2023; 18:962. [PMID: 38093357 PMCID: PMC10720077 DOI: 10.1186/s13018-023-04461-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Accepted: 12/10/2023] [Indexed: 12/17/2023] Open
Abstract
BACKGROUND Oblique lateral lumbar fusion (OLIF) is widely used in spinal degeneration, deformity and other diseases. The purpose of this study was to investigate the biomechanical differences between two different shapes of OLIF cages on whether to add posterior internal fixation system, using finite element analysis. METHODS A complete three-dimensional finite element model is established and verified for L3-L5. Surgical simulation was performed on the verified model, and the L4-L5 was the surgical segment. A total of the stand-alone group (Model A1, Model B1) and the BPSF group (Model A2, Model B2) were constructed. The four OLIF surgical models were: A1. Stand-alone OLIF with a kidney-shaped Cage; B1. Stand-alone OLIF with a straight cage; A2. OLIF with a kidney-shaped cage + BPSF; B2. Stand-alone OLIF with a straight cage + BPSF, respectively. The differences in the range of motion of the surgical segment (ROM), equivalent stress peak of the cage (ESPC), the maximum equivalent stress of the endplate (MESE) and the maximum stress of the internal fixation (MSIF) were compared between different models. RESULTS All OLIF surgical models showed that ROM declines between 74.87 and 96.77% at L4-L5 operative levels. The decreasing order of ROM was Model A2 > Model B2 > Model A1 > Model A2. In addition, the ESPC and MESE of Model A2 are smaller than those of other OLIF models. Except for the left-bending position, the MSIF of Model B2 increased by 1.51-16.69% compared with Model A2 in each position. The maximum value of MESE was 124.4 Mpa for Model B1 in the backward extension position, and the minimum value was 7.91 Mpa for Model A2 in the right rotation. Stand-alone group showed significantly higher ROMs and ESPCs than the BPSF group, with maximum values of 66.66% and 70.59%. For MESE, the BPSF group model can be reduced by 89.88% compared to the stand-alone group model. CONCLUSIONS Compared with the traditional straight OLIF cage, the kidney-shaped OLIF cage can further improve the stability of the surgical segment, reduce ESPC, MESE and MSIF, and help to reduce the risk of cage subsidence.
Collapse
|
5
|
Oblique lateral interbody fusion with internal fixations in the treatment for cross-segment degenerative lumbar spine disease (L2-3 and L4-5) finite element analysis. Sci Rep 2023; 13:17116. [PMID: 37816744 PMCID: PMC10564781 DOI: 10.1038/s41598-023-43399-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2022] [Accepted: 09/22/2023] [Indexed: 10/12/2023] Open
Abstract
Multi-segmental lumbar degenerative disease, including intersegmental disc degeneration, is found in clinical practice. Controversy still exists regarding the treatment for cross-segment degeneration. Oblique Lateral Interbody Fusion (OLIF) with several internal fixations was used to treat cross-segment lumbar degenerative disease. A whole lumbar spine model was extracted from CT images of the whole lumbar spine of patients with lumbar degeneration. The L2-3 and L4-5 intervertebral spaces were fused with OLIF using modeling software, the Pedicle screws were performed on L2-3 and L4-5, and different internal fixations were performed on L3-4 in Finite Element (FE) software. Among the six 10 Nm moments of different directions, the L3-4 no surgery (NS) group had the relatively largest Range of Motion (ROM) in the whole lumbar spine, while the L2-5 Long segmental fixation (LSF)group had the smallest ROM and the other groups had similar ROM. The ROM in the L1-2 and L5-S1 was relatively close in the six group models, and the articular cartilage stress and disc stress on the L1-2 and L5-S1 were relatively close. In contrast, the L3-4 ROM differed relatively greatly, with the LSF ROM the smallest and the NS ROM the largest, and the L3-4 Coflex (Coflex) group more active than the L3-4 Bacfuse (Bacfuse) group and the L3-4 translaminar facet screw fixation (TFSF) group. The stress on the articular cartilage and disc at L3-4 was relatively greater in the NS disc and articular cartilage, and greater in the Coflex group than in the Bacfuse and TFSF groups, with the greatest stress on the internal fixation in the TFSF group, followed by the Coflex group, and relatively similar stress in the Bacfuse, LSF, and NS groups. In the TFSF group, the stress on the internal fixation was greater than the yield strength among different directional moments of 10 Nm, which means it is unsuitable to be an internal fixation. The LSF group had the greatest overall ROM, which may lead to postoperative low back discomfort. The NS group has the greatest overall ROM, but its increased stress on the L3-4 disc and articular cartilage may lead to accelerated degeneration of the L3-4 disc and articular cartilage. The Coflex and Bacfuse groups had a reduced L3-4 ROM but a greater stress on disc compared to the LSF group, which may lead to disc degeneration in the long term. However, their stress on the articular cartilage was relatively low. Coflex and Bacfuse can still be considered better surgical options.
Collapse
|
6
|
Antepsoas Approaches to the Lumbar Spine. Neurosurg Clin N Am 2023; 34:619-632. [PMID: 37718108 DOI: 10.1016/j.nec.2023.06.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/19/2023]
Abstract
Lumbar interbody fusion (LIF) is a well-established approach in treating spinal deformity and degenerative conditions of the spine. Since its inception in the 20th century, LIF has continued to evolve, allowing for minimally invasive approaches, high fusion rates, and improving disability scores with favorable complication rates. The anterior to the psoas (ATP) approach utilizes a retroperitoneal pathway medial to the psoas muscle to access the L1-S1intervertebral disc spaces. In contrast to the transpsoas arppoach, its primary advantage is avoiding transgressing the psoas muscle and the contained lumbar plexus, which potentially decreases the risk of injury to the lumbar plexus. Avoiding transgression of the psoas may minimize the risk of transient or permanent neurological deficits secondary to lumbar plexus injury. Indications for ATP approaches may expand as it is shown to be a safe and effective method of achieving spinal arthrodesis.
Collapse
|
7
|
Biomechanical study of two-level oblique lumbar interbody fusion with different types of lateral instrumentation: a finite element analysis. Front Med (Lausanne) 2023; 10:1183683. [PMID: 37457575 PMCID: PMC10345158 DOI: 10.3389/fmed.2023.1183683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Accepted: 06/09/2023] [Indexed: 07/18/2023] Open
Abstract
Objective The aim of this study was to verify the biomechanical properties of a newly designed angulated lateral plate (mini-LP) suited for two-level oblique lumbar interbody fusion (OLIF). The mini-LP is placed through the lateral ante-psoas surgical corridor, which reduces the operative time and complications associated with prolonged anesthesia and placement in the prone position. Methods A three-dimensional nonlinear finite element (FE) model of an intact L1-L5 lumbar spine was constructed and validated. The intact model was modified to generate a two-level OLIF surgery model augmented with three types of lateral fixation (stand-alone, SA; lateral rod screw, LRS; miniature lateral plate, mini-LP); the operative segments were L2-L3 and L3-L4. By applying a 500 N follower load and 7.5 Nm directional moment (flexion-extension, lateral bending, and axial rotation), all models were used to simulate human spine movement. Then, we extracted the range of motion (ROM), peak contact force of the bony endplate (PCFBE), peak equivalent stress of the cage (PESC), peak equivalent stress of fixation (PESF), and stress contour plots. Results When compared with the intact model, the SA model achieved the least reduction in ROM to surgical segments in all motions. The ROM of the mini-LP model was slightly smaller than that of the LRS model. There were no significant differences in surgical segments (L1-L2, L4-L5) between all surgical models and the intact model. The PCFBE and PESC of the LRS and the mini-LP fixation models were lower than those of the SA model. However, the differences in PCFBE or PESC between the LRS- and mini-LP-based models were not significant. The fixation stress of the LRS- and mini-LP-based models was significantly lower than the yield strength under all loading conditions. In addition, the variances in the PESF in the LRS- and mini-LP-based models were not obvious. Conclusion Our biomechanical FE analysis indicated that LRS or mini-LP fixation can both provide adequate biomechanical stability for two-level OLIF through a single incision. The newly designed mini-LP model seemed to be superior in installation convenience, and equally good outcomes were achieved with both LRS and mini-LP for two-level OLIF.
Collapse
|
8
|
Oblique lumbar interbody fusion combined with stress end plate augmentation and anterolateral screw fixation for degenerative lumbar spinal stenosis with osteoporosis: a matched-pair case-controlled study. Spine J 2023; 23:523-532. [PMID: 36539041 DOI: 10.1016/j.spinee.2022.12.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Revised: 11/18/2022] [Accepted: 12/07/2022] [Indexed: 12/23/2022]
Abstract
BACKGROUND CONTEXT Oblique lumbar interbody fusion (OLIF) has been proven to be effective in treating degenerative lumbar spinal stenosis (DLSS). Whether OLIF is suitable for treating patients with DLSS with osteoporosis (OP) is still controversial. Bone cement augmentation is widely used to enhance the internal fixation strength of osteoporotic spines. However, the effectiveness of OLIF combined with bone cement stress end plate augmentation (SEA) and anterolateral screw fixation (AF) for DLSS with OP have not confirmed yet. PURPOSE To evaluate the clinical, radiological, and functional outcomes of OLIF-AF versus OLIF-AF-SEA in the treatment of DLSS with OP. STUDY DESIGN Retrospective case-control study. PATIENT SAMPLE A total of 60 patients with OP managed for DLSS at L4-L5. OUTCOME MEASURES Visual analog scale (VAS) score of the lower back and leg, Oswestry Disability Index (ODI), disk height (DH), lumbar lordosis (LL), segmental lordosis (SL), cage subsidence and fusion rate. METHODS The study was performed as a retrospective matched-pair case‒controlled study. Patients with OP managed for DLSS at L4-L5 between October 2017 and June 2020 and completed at least 2 years of follow-up were included, which were 30 patients treated by OLIF-AF and 30 patients undergoing OLIF-AF-SEA. The demographics and radiographic data, fusion status and functional outcomes were therefore compared to evaluate the efficacy of the two approaches. RESULTS Pain and disability improved similarly in both groups at the 24-month follow-up. However, the SEA group had lower pain and functional disability at 3 months postoperatively (p<.05). The mean postoperative disc height decrease (△DH) was significantly lower in the SEA group than in the control group (1.17±0.81 mm vs 2.89±2.03 mm; p<.001). There was no significant difference in lumbar lordosis (LL) or segmental lordosis (SL) between the groups preoperatively and 1 day postoperatively. However, a statistically significant difference was observed in SL and LL between the groups at 24 months postoperatively (p<.05). CS was observed in 4 cases (13.33%) in the SEA group and 17 cases (56.67%) in the control group (p<.001). A nonsignificant difference was observed in the fusion rate between the SEA and control groups (p=.347) at 24 months postoperatively. CONCLUSIONS This study revealed that OLIF-AF-SEA was safe and effective in the treatment of DLSS with OP. Compared with OLIF-AF, OLIF-AF-SEA results in a minor postoperative disc height decrease, a lower rate of CS, better sagittal balance, and no adverse effect on interbody fusion.
Collapse
|
9
|
Biomechanical Evaluation of Lateral Lumbar Interbody Fusion with Various Fixation Options for Adjacent Segment Degeneration: A Finite Element Analysis. World Neurosurg 2023; 173:e156-e167. [PMID: 36775239 DOI: 10.1016/j.wneu.2023.02.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2023] [Accepted: 02/04/2023] [Indexed: 02/12/2023]
Abstract
OBJECTIVE Adjacent segment degeneration (ASD) is a common phenomenon after lumbar fusion. Lateral lumbar interbody fusion (LLIF) may provide an alternative treatment method for ASD. This study used finite element analysis to evaluate the biomechanical effects of LLIF with various fixation options and identify an optimal surgical strategy for ASD. METHODS A validated L1-S1 finite element model was modified for simulation. Six finite element models of the lumbar spine were created and were divided into group 1 (L4-5 posterior lumbar interbody fusion [PLIF] + L3-4 LLIF) and group 2 (L5-S1 PLIF + L4-5 LLIF). Each group consisted of 1) cage-alone, 2) cage + lateral screw fixation (LSF), and 3) cage + bilateral pedicle screw fixation (BPSF) models. The range of motion, intradiscal pressure, and facet loads of adjacent segments as well as interbody cage stress were analyzed. RESULTS The stress on the LLIF cage-superior endplate interface was highest in the cage-alone model followed by the cage + LSF model and cage + BPSF model. The increase in range of motion, intradiscal pressure, and facet loads at the adjacent segment was highest in the cage + BPSF model followed by the cage + LSF model and cage-alone model. However, the biomechanical effect on the adjacent segment seemed similar in the cage-alone and cage + LSF models. CONCLUSIONS LLIF with BPSF is recommended when performing LLIF surgery for ASD after L4-5 and L5-S1 PLIF. Considering cage subsidence and biomechanical effects on the adjacent segment, LLIF with LSF may be a suboptimal option for ASD surgery.
Collapse
|
10
|
Comparison of the biomechanical effects of lumbar disc degeneration on normal patients and osteoporotic patients: A finite element analysis. Med Eng Phys 2023; 112:103952. [PMID: 36842775 DOI: 10.1016/j.medengphy.2023.103952] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2022] [Revised: 12/17/2022] [Accepted: 01/07/2023] [Indexed: 01/10/2023]
Abstract
BACKGROUND Some older patients who suffered from both conditions (disc degeneration and osteoporosis) have higher surgical risks and longer postoperative recovery times. Understanding the relation between disc degeneration and osteoporosis is fundamental to know the mechanisms of orthopedic disorders and improve clinical treatment. However, there is a lack of finite element (FE) studies to predict the combined effects of disc degeneration and osteoporosis. So the aim of the present study is to explore the differences of biomechanical effects of lumbar disc degeneration on normal patients and osteoporotic patients. METHODS A normal lumbar spine finite element model (FEM) was developed based on the geometric information of a healthy male subject (age 35 years; height 178 cm; weight 65 kg). This normal lumbar spine FEM was modified to build three lumbar spine degeneration models simulating mild, moderate and severe grades of disc degeneration at the L4-L5 segment. Then the degenerative lumbar spine models for osteoporotic patients were constructed on the basis of the above-mentioned degeneration models. Firstly, the normal model (flexion: 8 Nm; extension: 6 Nm; lateral bending: 6 Nm; torsion: 4 Nm) and degenerative models (10 Nm) were calibrated under pure moment load, respectively. Secondly, under a 400 N follower load, the 7.5 Nm moments of different directions were applied on all models to simulate different motion postures. Finally, under the above loading conditions, we calculated and analyzed the range of motion (ROM), Mises stress in cortical (MSC1), Mises stress in endplate (MSE), Mises stress in cancellous (MSC2), and Mises stress in post (MSP). RESULTS Compared with disc degeneration patients without osteoporosis, the ROM, MSC1, and MSE of osteoporosis patients with various disc degeneration decreased in all postures, while the MSC2 and MSP increased. With increase in the degree of disc degeneration, the reduction proportions of ROM and MSE in osteoporotic patients gradually increased, while the reduction percentages in MSC1 of osteoporotic patients gradually decreased. The increase percentages of MSC2 in osteoporotic patients gradually increased. Given the progressive changes of disc degeneration, the changes in MSP in osteoporosis patients were uneven. CONCLUSION In summary, the effect of disc degeneration on flexibility in the two kinds of patients (osteoporosis and non-osteoporosis patients) was nearly same. By comparing the remaining biomechanical parameters (MSC1, MSE, MSC2, and MSP), we found that degenerated intervertebral discs caused changes in loading patterns of osteoporosis patients. Disc degeneration reduced the Mises stress in the cortical and endplate, which increased the Mises stress in the cancellous and post. That is to say, in order to cope with the changes in bone stresses caused by disc degeneration and osteoporosis, clinicians should be more careful in choosing the surgical option for osteoporotic patients with disc degeneration.
Collapse
|
11
|
Biomechanical evaluation of two-level oblique lumbar interbody fusion combined with posterior four-screw fixation:A finite element analysis. Clin Neurol Neurosurg 2023; 225:107597. [PMID: 36696847 DOI: 10.1016/j.clineuro.2023.107597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2022] [Accepted: 01/15/2023] [Indexed: 01/18/2023]
Abstract
OBJECTIVE By constructing the three-dimensional finite element model of two-level OLIF lumbar spine, the aim of this study was to demonstrate the feasibility and effectiveness of posterior four-screw fixation for treatment of two-level lumbar degenerative diseases from the perspective of biomechanics. METHODS An intact L3-S1 segment nonlinear lumbar finite element model (M0) was constructed from the CT scanning data of a healthy adult. After verification, two-level OLIF procedure were simulated, and three patterns of finite element analysis models were constructed: two-level stand-alone OLIF group (M1), two-level OLIF + four-screw fixation group (M2) and two-level OLIF + six-screw fixation group (M3). Range of motion, stress of the cage, and stress of fixation were evaluated in the different models. RESULTS Under various motion modes,the ROM of M2 and M3 were significantly lower than those of M1. The ROM reduction of M2 relative to M1 was much greater than that of M3 relative to M2. Moreover, the peak von Mises stresses of endplates in M2 were almost the same as those in M3. In terms of the maximum stresses of cages, M2 and M3 were essentially identical. Besides, the maximum stresses of posterior instrumentation in M2 and M3 were similar, which were mainly concentrated at the root of pedicle screws. CONCLUSION There were no significant differences between M2 and M3 from the biomechanical analysis. In two-level OLIF, posterior four-screw fixation can replace six-screw fixation, which reduces surgical trauma and decreases economic burden of patients, and will be a cost-effective alternative.
Collapse
|
12
|
Biomechanical Performances of an Oblique Lateral Interbody Fusion Cage in Models with Different Bone Densities: A Finite Element Analysis. Indian J Orthop 2023; 57:86-95. [PMID: 36660489 PMCID: PMC9789258 DOI: 10.1007/s43465-022-00775-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2022] [Accepted: 11/07/2022] [Indexed: 11/18/2022]
Abstract
Study Design Finite element models of the L3-S1 vertebrae were reconstructed using computed tomography scans. Objective We compared the biomechanical performances of an oblique lateral interbody fusion (OLIF) cage in different bone density mode. Summary of Background Data Low bone density is an els.key factor limiting the use of stand-alone OLIF cage. Methods Four models-intact (M0), normal bone density with OLIF (M1), bone mass loss with OLIF (M2), and osteoporotic with OLIF (M3)-were created based on 3-dimensional scans. Flexion, extension, and lateral bending movements (each lasting 10 N·m) were performed on the superior surface of the L3 vertebra with a compressive preload of 500 N. Range of motion (ROM), peak stresses in the L4-5 cortical endplates, cage stress, and adjacent intervertebral disk stress were evaluated. Results ROMs during different physiological movements were similar to those reported by previous researchers. Compared with that in M0, L4-5 ROMs of all movements decreased in M1, M2 and M3, most evidently in M3. Stress distribution in the cortical endplates rose to 7.8% in M1 and M2, even 16.2% in M3. Cage stress increased by less than 8.1% in M1 and M2, but by 25.3% in M3, especially in the movements of extension and right rotation. Compared with that in M0, L3-4 and L5-S1 intervertebral disk stress increased with bone density in all the other models, by up to 69.8% and 98.3%, respectively. As osteoporosis worsened, stress in the adjacent intervertebral disk also increased. Conclusion Stand-alone OLIF in M3 is not recommended because of the risk of cage subsidence. OLIF in M1 and M2 achieved similar results in various lumbar spine movements. In M1 and M2 model (T > - 2.5), the L4-L5 showed reduced mobility in all directions, increased rigidity, limited cage displacement, lessened deformation, and better stability.
Collapse
|
13
|
Recent advancement in finite element analysis of spinal interbody cages: A review. Front Bioeng Biotechnol 2023; 11:1041973. [PMID: 37034256 PMCID: PMC10076720 DOI: 10.3389/fbioe.2023.1041973] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Accepted: 03/13/2023] [Indexed: 04/11/2023] Open
Abstract
Finite element analysis (FEA) is a widely used tool in a variety of industries and research endeavors. With its application to spine biomechanics, FEA has contributed to a better understanding of the spine, its components, and its behavior in physiological and pathological conditions, as well as assisting in the design and application of spinal instrumentation, particularly spinal interbody cages (ICs). IC is a highly effective instrumentation for achieving spinal fusion that has been used to treat a variety of spinal disorders, including degenerative disc disease, trauma, tumor reconstruction, and scoliosis. The application of FEA lets new designs be thoroughly "tested" before a cage is even manufactured, allowing bio-mechanical responses and spinal fusion processes that cannot easily be experimented upon in vivo to be examined and "diagnosis" to be performed, which is an important addition to clinical and in vitro experimental studies. This paper reviews the recent progress of FEA in spinal ICs over the last six years. It demonstrates how modeling can aid in evaluating the biomechanical response of cage materials, cage design, and fixation devices, understanding bone formation mechanisms, comparing the benefits of various fusion techniques, and investigating the impact of pathological structures. It also summarizes the various limitations brought about by modeling simplification and looks forward to the significant advancement of spine FEA research as computing efficiency and software capabilities increase. In conclusion, in such a fast-paced field, the FEA is critical for spinal IC studies. It helps in quantitatively and visually demonstrating the cage characteristics after implanting, lowering surgeons' learning costs for new cage products, and probably assisting them in determining the best IC for patients.
Collapse
|
14
|
Biomechanical evaluation of lumbar spondylolysis repair with various fixation options: A finite element analysis. Front Bioeng Biotechnol 2022; 10:1024159. [DOI: 10.3389/fbioe.2022.1024159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2022] [Accepted: 10/05/2022] [Indexed: 11/13/2022] Open
Abstract
Objective: This study was designed to compare the biomechanical properties of lumbar spondylolysis repairs using different fixation methods by using three-dimensional finite element analysis.Methods: Five finite element models (A, B, C, D, and E) of L4-S1 vertebral body were reconstructed by CT images of a male patient (A: intact model; B: spondylolysis model; C: spondylolysis model with intrasegmental direct fixation by Buck screw; D: spondylolysis model with intersegmental indirect fixation by pedicle screw system; E: spondylolysis model with hybrid internal fixation). L5-S1 level was defined as the operative level. After the intact model was verified, six physiological motion states were simulated by applying 500 N concentrated force and 10 Nm torque on the upper surface of L4. The biomechanical properties of the three different internal fixation methods were evaluated by comparing the range of motion (ROM), maximum stress, and maximum displacement.Results: Compared with Model B, the ROM and maximum displacement of Model C, D, and E decreased. The maximum stress on L5/S1 disc in models A, B, and C was much higher than that in Model D and E under extension and lateral bending conditions. Under axial rotation and lateral bending conditions, the maximum stress of interarticular muscle and internal fixation system in Model B and Model C was significantly higher than that in Model D and Model E. In contrast to Model D, the stress in Model E was distributed in two internal fixation systems.Conclusion: In several mechanical comparisons, hybrid fixation had better biomechanical properties than other fixation methods. The experimental results show that hybrid fixation can stabilize the isthmus and reduce intervertebral disc stress, which making it the preferred treatment for lumbar spondylolysis.
Collapse
|
15
|
Cervical Lift-up Basket Laminoplasty after Resection of Spinal Intramedullary Tumors: A Finite Element Analysis and Clinical Image Evaluation. Neurol Med Chir (Tokyo) 2022; 62:559-565. [PMID: 36184479 PMCID: PMC9831624 DOI: 10.2176/jns-nmc.2022-0172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023] Open
Abstract
Although reconstructive laminoplasty is commonly performed after resection of spinal intramedullary tumors of the cervical spine, its biomechanical rigidity of laminoplasty framework remains unclear. The objective of this study was to examine the structural reliability of our unique method of cervical lift-up basket laminoplasty by using computed tomography (CT)-based finite element analysis (FEA) and clinical radiological evaluation. A finite element model of cervical laminoplasty was created based on CT images using FEA software. Cervical lift-up basket laminoplasty (Basket) was compared with the standard style of open-door basket laminoplasty (Open-door). Clinical subjects for radiological evaluation comprised 33 patients who underwent cervical lift-up basket laminoplasty after resection of spinal intramedullary tumors. An FEA-equivalent stress histogram showed that stress was moderately dispersed around the basket. Virtual displacement of the spinous process of the Basket model was equivalent to that of the Open-door model in any direction of posterior-to-anterior, right-to-left, or top-to-bottom force. In the clinical analysis, radiological data with a minimum postoperative period of 6 months were obtained in a total of 28 out of 33 patients. No patients underwent revision surgery because of implant-related complications. No significant differences in C2-C7 angle or cervical tilt angle were observed between pre- and postoperatively. The structural rigidity of cervical lift-up basket laminoplasty was equivalent to the open-door style on the FEA. Clinical radiological evaluation suggested that there were no serious adverse events associated with cervical laminoplasty, although the longer postoperative follow-up is mandatory.
Collapse
|
16
|
Biomechanical characteristics of 2 different posterior fixation methods of bilateral pedicle screws: A finite element analysis. Medicine (Baltimore) 2022; 101:e30419. [PMID: 36086784 PMCID: PMC10980486 DOI: 10.1097/md.0000000000030419] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2022] [Accepted: 07/27/2022] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND To explore the biomechanical characteristics of 2 posterior bilateral pedicle screw fixation methods using finite element analysis. METHODS A normal L3-5 finite element model was established. Based on the verification of its effectiveness, 2 different posterior internal fixation methods were simulated: bilateral pedicle screws (model A) were placed in the L3 and L5 vertebral bodies, and bilateral pedicle screws (model B) were placed in the L3, L4, and L5 vertebral bodies. The stability and stress differences of intervertebral discs, endplates, screws, and rods between models were compared. RESULTS Compared with the normal model, the maximum stress of the range of motion, intervertebral disc, and endplate of the 2 models decreased significantly. Under the 6 working conditions, the 2 internal fixation methods have similar effects on the stress of the endplate and intervertebral disc, but the maximum stress of the screws and rods of model B is smaller than that of model A. CONCLUSIONS Based on these results, it was found that bilateral pedicle screw fixation in 2 vertebrae L3 and L5 can achieve similar stability as bilateral pedicle screw fixation in 3 vertebrae L3, L4, and L5. However, the maximum stress of the screw and rod in model B is less than that in model A, so this internal fixation method can effectively reduce the risk of fracture. The 3-dimensional finite element model established in this study is in line with the biomechanical characteristics of the spine and can be used for further studies on spinal column biomechanics. This information can serve as a reference for clinicians for surgical selection.
Collapse
|
17
|
Successful Criteria for Indirect Decompression With Lateral Lumbar Interbody Fusion. Neurospine 2022; 19:805-815. [PMID: 35945700 PMCID: PMC9537858 DOI: 10.14245/ns.2244058.029] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Accepted: 05/25/2022] [Indexed: 12/14/2022] Open
Abstract
OBJECTIVE No consensus criteria have been established regarding ideal candidates for indirect decompression with lateral lumbar interbody fusion (LLIF), and contributing factors of indirect decompression failure were rarely reported. We aim to investigate the success rate of indirect decompression by LLIF with proposed selection criteria and identify risk factors associated with indirect decompression failure, defined as persistent pain requiring revision with direct decompression. METHODS Data from 191 patients undergoing LLIF were retrospectively reviewed. All the following criteria must be fulfilled: (1) dynamic clinical symptoms (pain relief in supine position), (2) presence of reducible disc height (recovered disc height in supine position), (3) no profound weakness, and (4) no static stenosis. The success rate of indirect decompression with LLIF and results after at least 1 year of follow-up were collected. Preoperative, procedure-related, and postoperative factors were assessed for their relationship with failure. RESULTS Of 191 patients,13 patients (6.8%) required additional direct decompression due to persistent pain, giving a criteria success rate of 93.2%. Factors associated with indirect decompression failure included low bone mineral density (T-score < 2.1), low reducible disc height (<13%), low postoperative disc height (< 10 mm), high-grade cage subsidence, and use of plate fixation. CONCLUSION We proposed patient selection criteria for indirect decompression with LLIF which had a satisfactory success rate and identified factors associated with the need for additional direct decompression. Our proposed criteria may assist selection of patients likely to achieve good results following indirect decompression with LLIF, and optimize selection based on risk factors of failure.
Collapse
|
18
|
Analysis of the drainage effect of different incisions for high complex anal fistula based on FLUENT hydrodynamic simulation. Front Surg 2022; 9:974341. [PMID: 36034382 PMCID: PMC9412015 DOI: 10.3389/fsurg.2022.974341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Accepted: 07/28/2022] [Indexed: 11/13/2022] Open
Abstract
Purpose The biomechanical characteristics of the trauma size and postoperative drainage of different incisions for high complex anal fistula surgery were compared by numerical simulation analysis to provide a theoretical basis for the clinical selection of minimally invasive incisions for surgery. Methods Using FLUENT finite element software, a typical incision finite element model was established to obtain incision areas, and the total mass outlet flow within 200 s was calculated to evaluate the drainage effect of each incision. Results The incisions with the largest to smallest areas were the curved, spindle, and curved plus extended groove incision, indicating that the curved plus extended groove incision caused the least damage to the perianal skin muscles. Conversely, the incisions with the largest to smallest total outlet flow were as follows: curved plus extended groove, spindle, curved, and straight incision, suggesting that the curved plus extended groove model had the best diversion effect, and the curved incision had better diversion effect than that of the straight incision. Conclusion The curved plus extended groove surgical incision had the smallest incision area, minimized damage to the perianal skin and muscle tissue, conformed to the concept of minimally invasive surgery, ensured adequate drainage of exudate, maintained the normal growth of granulation tissue on the wound surface, preserved the original form of the anus, and thus better protected the function of the anus. This improved the quality of life of patients requiring high complex anal fistulas.
Collapse
|
19
|
Effect of the In Situ Screw Implantation Region and Angle on the Stability of Lateral Lumbar Interbody Fusion: A Finite Element Study. Orthop Surg 2022; 14:1506-1517. [PMID: 35656700 PMCID: PMC9251290 DOI: 10.1111/os.13312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Revised: 04/13/2022] [Accepted: 04/19/2022] [Indexed: 11/27/2022] Open
Abstract
Objective To investigate the effect of the in situ screw implantation region and angle on the stability of lateral lumbar interbody fusion (LLIF) from a biomechanical perspective. Methods A validated L2‐4 finite element (FE) model was modified for simulation. The L3‐4 fused segment undergoing LLIF surgery was modeled. The area between the superior and inferior edges and the anterior and posterior edges of the vertebral body (VB) is divided into four zones by three parallel lines in coronal and horizontal planes. In situ screw implantation methods with different angles based on the three parallel lines in coronal plane were applied in Models A, B, and C (A: parallel to inferior line; B: from inferior line to midline; C: from inferior line to superior line). In addition, four implantation methods with different regions based on the three parallel lines in horizontal plane were simulated as types 1–2, 1–3, 2–2, and 2–3 (1–2: from anterior line to midline; 1–3: from anterior line to posterior line; 2–2: parallel to midline; 2–3: from midline to posterior line). L3‐4 ROM, interbody cage stress, screw‐bone interface stress, and L4 superior endplate stress were tracked and calculated for comparisons among these models. Results The L3‐4 ROM of Models A, B, and C decreased with the extent ranging from 47.9% (flexion‐extension) to 62.4% (lateral bending) with no significant differences under any loading condition. Types 2–2 and 2–3 had 45% restriction, while types 1–2 and 1–3 had 51% restriction in ROM under flexion‐extension conditions. Under lateral bending, types 2–2 and 2–3 had 70.6% restriction, while types 1–2 and 1–3 had 61.2% restriction in ROM. Under axial rotation, types 2–2 and 2–3 had 65.2% restriction, while types 1–2 and 1–3 had 59.3% restriction in ROM. The stress of the cage in types 2–2 and 2–3 was approximately 20% lower than that in types 1–2 and 1–3 under all loading conditions in all models. The peak stresses at the screw‐bone interface in types 2–2 and 2–3 were much lower (approximately 35%) than those in types 1–2 and 1–3 under lateral bending, while no significant differences were observed under flexion‐extension and axial rotation. The peak stress on the L4 superior endplate was approximately 30 MPa and was not significantly different in all models under any loading condition. Conclusions Different regions of entry‐exit screws induced multiple screw trajectories and influenced the stability and mechanical responses. However, different implantation angles did not. Considering the difficulty of implantation, the ipsilateral‐contralateral trajectory in the lateral middle region of the VB can be optimal for in situ screw implantation in LLIF surgery.
Collapse
|
20
|
Comparison of the susceptibility to implant failure in the lateral, posterior, and transforaminal lumbar interbody fusion: A finite element analysis. World Neurosurg 2022; 164:e835-e843. [PMID: 35605942 DOI: 10.1016/j.wneu.2022.05.056] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Accepted: 05/13/2022] [Indexed: 11/19/2022]
Abstract
OBJECTIVE There are several techniques for lumbar interbody fusion, and implant failure following lumbar interbody fusion can be troublesome. This study aimed to compare the stress in posterior implant and peri-screw vertebral bodies among lateral lumbar interbody fusion (LLIF), posterior lumbar interbody fusion (PLIF), and transforaminal lumbar interbody fusion (TLIF) and to select the technique that is least likely to cause implant failure. METHODS We created an intact L3-L5 model and simulated the LLIF, PLIF, and TLIF techniques at L4-L5 using finite element methods. All models at the lower portion of L5 were fixed and imposed a preload of 400 N and a moment of 7.5 Nm on the upper portion of L3 to simulate flexion, extension, lateral bending, and axial rotation. We investigated the peak stresses and stress concentration in the posterior implant and peri-screw vertebral bodies for the LLIF, PLIF, and TLIF techniques. RESULTS The extension, flexion, bending, and rotation peak stresses and stress concentration in the posterior implant, and the peri-screw vertebral bodies, were the lowest in LLIF, followed by PLIF and TLIF, respectively. CONCLUSIONS It was found that implant failure was least likely to occur in LLIF, followed by PLIF and TLIF, respectively. Hence, surgeons should be aware of these factors when selecting an appropriate surgical technique and be careful for implant failure during postoperative follow-up.
Collapse
|
21
|
Biomechanical Evaluation of an Oblique Lateral Locking Plate System for Oblique Lumbar Interbody Fusion: A Finite Element Analysis. World Neurosurg 2022; 160:e126-e141. [PMID: 35031519 DOI: 10.1016/j.wneu.2021.12.105] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2021] [Revised: 12/26/2021] [Accepted: 12/27/2021] [Indexed: 01/24/2023]
Abstract
OBJECTIVE The oblique lateral locking plate system (OLLPS) is a novel internal fixation with a locking and reverse pedicle track screw configuration designed for oblique lumbar interbody fusion (OLIF). The OLLPS is placed in a single position through the oblique lateral surgical corridor to reduce operative time and complications associated with prolonged anesthesia and prone positioning. The purpose of this study was to verify the biomechanical effect of the OLLPS. METHODS An intact finite element model of L1-S1 (intact) was established based on computed tomography images of a healthy male volunteer. The L4-L5 intervertebral space was selected as the surgical segment. The surgical models were established separately based on OLIF surgical procedures and different internal fixations: 1) stand-alone OLIF (SA); 2) OLIF with a 2-screw lateral plate; 3) OLIF with a 4-screw lateral plate; 4) OLIF with OLLPS; and 5) OLIF with bilateral pedicle screw fixation (BPS). After validation of the intact model, physiologic loads were applied to the superior surface of L1 to simulate motions such as flexion, extension, left bending, right bending, left rotation, and right rotation. The evaluation indices included the L4/5 range of motion, the L4 maximum displacement, and the maximum stresses of the superior and inferior end plates, the cage, and the supplemental fixation. RESULTS During OLIF surgery, the OLLPS provided multiplanar stability similar to that provided by BPS. Compared with 2-screw lateral plate and 4-screw lateral plate, OLLPS had better biomechanical properties in terms of enhancing the instant stability of the surgical segment, reducing the stress on the superior and inferior end plates of the surgical segment, and decreasing the risk of cage subsidence. CONCLUSIONS With a minimally invasive background, the OLLPS can be used as an alternative to BPS in OLIF and it has better prospects for clinical promotions and applications.
Collapse
|
22
|
Pearls and Pitfalls of Oblique Lateral Interbody Fusion: A Comprehensive Narrative Review. Neurospine 2022; 19:163-176. [PMID: 35378589 PMCID: PMC8987540 DOI: 10.14245/ns.2143236.618] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2021] [Accepted: 01/13/2022] [Indexed: 12/12/2022] Open
Abstract
Lumbar degenerative disease is a common problem in an aging society. Oblique lateral interbody fusion (OLIF) is a minimally invasive surgical (MIS) technique that utilizes a retroperitoneal antepsoas corridor to treat lumbar degenerative disease. OLIF has theoretical advantages over other lumbar fusion techniques, such as a lower risk of lumbar plexus injury than direct lateral interbody fusion (DLIF). Previous studies have reported favorable clinical and radiological outcomes of OLIF in various lumbar degenerative diseases. The use of OLIF is increasing, and evidence on OLIF is growing in the literature. The indications for OLIF are also expanding with the help of recent technical developments, including stereotactic navigation systems and robotics. In this review, we present current evidence on OLIF for the treatment of lumbar degenerative disease, focusing on the expansion of surgical indications and recent advancements in the OLIF procedure.
Collapse
|
23
|
Oblique lateral interbody fusion combined with different internal fixations for the treatment of degenerative lumbar spine disease: a finite element analysis. BMC Musculoskelet Disord 2022; 23:206. [PMID: 35246101 PMCID: PMC8897936 DOI: 10.1186/s12891-022-05150-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Accepted: 02/24/2022] [Indexed: 11/15/2022] Open
Abstract
Background Little is known about the biomechanical performance of different internal fixations in oblique lumbar interbody fusion (OLIF). Here, finite element (FE) analysis was used to describe the biomechanics of various internal fixations and compare and explore the stability of each fixation. Methods CT scans of a patient with lumbar degenerative disease were performed, and the l3-S1 model was constructed using relevant software. The other five FE models were constructed by simulating the model operation and adding different related implants, including (1) an intact model, (2) a stand-alone (SA) model with no instrument, (3) a unilateral pedicle screw model (UPS), (4) a unilateral pedicle screw contralateral translaminar facet screw model (UPS-CTFS), (5) a bilateral pedicle screw (BPS) model, and (6) a cortical bone trajectory screw model (CBT). Various motion loads were set by FE software to simulate lumbar vertebral activity. The software was also used to extract the range of motion (ROM) of the surgical segment, CAGE and fixation stress in the different models. Results The SA group had the greatest ROM and CAGE stress. The ROM of the BPS and UPS-CTFS was not significantly different among motion loadings. Compared with the other three models, the BPS model had lower internal fixation stress among loading conditions, and the CBT screw internal fixation had the highest stress among loads. Conclusions The BPS model provided the best biomechanical stability for OLIF. The SA model was relatively less stable. The UPS-CTFS group had reduced ROM in the fusion segments, but the stresses on the internal fixation and CAGE were relatively higher in the than in the BPS group; the CBT group had a lower flexion and extension ROM and higher rotation and lateral flexion ROM than the BPS group. The stability of the CBT group was poorer than that of the BPS and LPS-CTFS groups. The CAGE and internal fixation stress was greater in the CBT group.
Collapse
|
24
|
Stability Evaluation of Different Oblique Lumbar Interbody Fusion Constructs in Normal and Osteoporotic Condition - A Finite Element Based Study. Front Bioeng Biotechnol 2021; 9:749914. [PMID: 34805108 PMCID: PMC8602101 DOI: 10.3389/fbioe.2021.749914] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Accepted: 10/11/2021] [Indexed: 12/20/2022] Open
Abstract
Introduction: In developed countries, the age structure of the population is currently undergoing an upward shift, resulting a decrease in general bone quality and surgical durability. Over the past decade, oblique lumbar interbody fusion (OLIF) has been globally accepted as a minimally invasive surgical technique. There are several stabilization options available for OLIF cage fixation such as self-anchored stand-alone (SSA), lateral plate-screw (LPS), and bilateral pedicle screw (BPS) systems. The constructs’ stability are crucial for the immediate and long-term success of the surgery. The aim of this study is to investigate the biomechanical effect of the aforementioned constructs, using finite element analysis with different bone qualities (osteoporotic and normal). Method: A bi-segmental (L2–L4) finite element (FE) model was created, using a CT scan of a 24-year-old healthy male. After the FE model validation, CAD geometries of the implants were inserted into the L3–L4 motion segment during a virtual surgery. For the simulations, a 150 N follower load was applied on the models, then 10 Nm of torque was used in six general directions (flexion, extension, right/left bending, and right/left rotation), with different bone material properties. Results: The smallest segmental (L3–L4) ROM (range of motion) was observed in the BPS system, except for right bending. Osteoporosis increased ROMs in all constructs, especially in the LPS system (right bending increase: 140.26%). Osteoporosis also increased the caudal displacement of the implanted cage in all models (healthy bone: 0.06 ± 0.03 mm, osteoporosis: 0.106 ± 0.07 mm), particularly with right bending, where the displacement doubled in SSA and LPS constructs. The displacement of the screws inside the L4 vertebra increased by 59% on average (59.33 ± 21.53%) due to osteoporosis (100% in LPS, rotation). BPS-L4 screw displacements were the least affected by osteoporosis. Conclusions: The investigated constructs provide different levels of stability to the spine depending on the quality of the bone, which can affect the outcome of the surgery. In our model, the BPS system was found to be the most stable construct in osteoporosis. The presented model, after further development, has the potential to help the surgeon in planning a particular spinal surgery by adjusting the stabilization type to the patient’s bone quality.
Collapse
|
25
|
Biomechanical Evaluation of Stand-Alone Oblique Lateral Lumbar Interbody Fusion Under 3 Different Bone Mineral Density Conditions: A Finite Element Analysis. World Neurosurg 2021; 155:e285-e293. [PMID: 34418606 DOI: 10.1016/j.wneu.2021.08.049] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 08/10/2021] [Accepted: 08/11/2021] [Indexed: 12/20/2022]
Abstract
OBJECTIVE To evaluate the biomechanical stability of stand-alone (SA) oblique lateral interbody fusion (OLIF) under different bone mineral density conditions. METHODS The finite element model of L2-L5 was reconstructed and verified via computed tomography scan images (M0). The L4-L5 segment of SA OLIF was created based on the validation model. By changing bone mineral density, SA OLIF was established in the normal bone mineral density group (M1), osteopenia group (M2), and osteoporosis group (M3). A 500 N vertical axial preload was imposed on the superior surface of L2, and a 10 N-m moment was applied on the L2 superior surface along the radial direction to simulate 6 different physiological motions: flexion, extension, left and right lateral bending, left and right rotation. RESULTS Compared with M0, the range of motion of the fusion segment was significantly reduced, and the maximum stress of the upper and lower end plates was significantly increased in all motion modes. Compared with M1, the maximum relative increases of range of motion, cephalic end-plate stress and tail end-plate stress of M2 in the L4-L5 segment were 39.1%, 9.9%, and 10.7%, and the maximum increases of the above parameters in M3 were 100%, 28.9%, and 31.6%. The maximum stress of the tail end plate of the M3 model during flexion was 54.617 MPa, which was very close to the yield stress of the lamellar bone (60 MPa). CONCLUSIONS With the increase of the degree of osteoporosis, the maximum stress on the upper and lower end plates of the fusion segment increased significantly, thus increasing the potential risk of implant subsidence. SA OLIF could not provide sufficient stability for patients with osteoporosis.
Collapse
|