1
|
Einbinder T, Machtei A, Birk E, Schamroth Pravda N, Frenkel G, Amir G, Fogelman R. Low Risk of Inappropriate Shock Among Pediatric Patients With an Implantable Cardioverter Defibrillator: A Single Center Experience. Pediatr Cardiol 2024; 45:1776-1783. [PMID: 37668692 DOI: 10.1007/s00246-023-03280-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Accepted: 08/17/2023] [Indexed: 09/06/2023]
Abstract
Implantable cardioverter-defibrillators (ICD) are increasingly being used among the pediatric population for indications of both primary and secondary prevention. There is limited long-term data on the outcomes of pediatric patients following ICD implantation. The aim of this study was to investigate the characteristics of this population, burden of appropriate and inappropriate shock and complication rate in a large tertiary pediatric medical center. Included were children under the age of 18 years who underwent ICD implantation and had clinical follow up at our center. Data were retrospectively collected between study period 2005-2020. Primary outcome was the incidence of ICD shock appropriate and inappropriate. Secondary outcome was defining our patient population characteristics. Our cohort included 51 patients who underwent ICD implantation. Mean age at implantation was 10.9 ± 4.7 years and average follow-up time was 67 months. Diagnoses of implanted patients were: 28 (55%) patients with syndromes with risk for sudden death, cardiomyopathy in 14 patients (27%) and congenital heart disease (CHD) in 9 patients (18%). Forty-two (82%) patients had an ICD implanted for secondary prevention after experiencing a life-threatening arrhythmia and 9 (18%) for primary prevention. An endocardial system was implanted in 39 (76%) patients and an epicardial systems in 12 (24%) patients. A total of 20 (39%) patients received appropriate shocks for ventricular fibrillation(VF). 5 patients received inappropriate shocks, 4 due to sinus tachycardia and 1 due to rapidly conducted atrial fibrillation. Those who received an inappropriate shock had a significantly shorter ICD-programmed VF detection cycle length compared to those who did not receive an inappropriate shock (320 ms versus 270 ms, p = 0.062). This single center study demonstrates a high rate of appropriate ICD shocks (39%) and a low rate of inappropriate ICD shocks. Accurate programming of ICD devices in the pediatric population is paramount to avoid inappropriate ICD shocks.
Collapse
Affiliation(s)
- Tom Einbinder
- Department of Pediatric Cardiology, Schneider's Children Medical Center, Petach-Tikva, Israel.
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
| | - Ayelet Machtei
- Department of Pediatric Cardiology, Schneider's Children Medical Center, Petach-Tikva, Israel
| | - Einat Birk
- Department of Pediatric Cardiology, Schneider's Children Medical Center, Petach-Tikva, Israel
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | | | - George Frenkel
- Department of Pediatric Cardiology, Schneider's Children Medical Center, Petach-Tikva, Israel
| | - Gabriel Amir
- Department of Pediatric Cardiology, Schneider's Children Medical Center, Petach-Tikva, Israel
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Rami Fogelman
- Department of Pediatric Cardiology, Schneider's Children Medical Center, Petach-Tikva, Israel
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
2
|
Silvetti MS, Bruyndonckx L, Maltret A, Gebauer R, Kwiatkowska J, Környei L, Albanese S, Raimondo C, Paech C, Kempa M, Fésüs G, Knops RE, Blom NA, Drago F. The SIDECAR project: S-IcD registry in European paediatriC and young Adult patients with congenital heaRt defects. Europace 2022; 25:460-468. [PMID: 36107451 PMCID: PMC9935000 DOI: 10.1093/europace/euac162] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Accepted: 08/04/2022] [Indexed: 11/13/2022] Open
Abstract
AIMS Subcutaneous-implantable cardiac defibrillators (S-ICDs) are used increasingly to prevent sudden cardiac death in young patients. This study was set up to gain insight in the indications for S-ICD, possible complications, and their predictors and follow-up results. METHODS AND RESULTS A multicentre, observational, retrospective, non-randomized, standard-of-care registry on S-ICD outcome in young patients with congenital heart diseases (CHDs), inherited arrhythmias (IAs), idiopathic ventricular fibrillation (IVF), and cardiomyopathies (CMPs). Anthropometry was registered as well as implantation technique, mid-term device-related complications, and incidence of appropriate/inappropriate shocks (IASs). Data are reported as median (interquartile range) or mean ± standard deviation. Eighty-one patients (47% CMPs, 20% CHD, 21% IVF, and 12% IA), aged 15 (14-17) years, with body mass index (BMI) 21.8 ± 3.8 kg/m2, underwent S-ICD implantation (primary prevention in 59%). This was performed with two-incision technique in 81% and with a subcutaneous pocket in 59%. Shock and conditional zones were programmed at 250 (200-250) and 210 (180-240) b.p.m., respectively. No intraoperative complications occurred. Follow up was 19 (6-35) months: no defibrillation failure occurred, 17% of patients received appropriate shocks, 13% of patients received IAS (supraventricular tachycardias 40%, T-wave oversensing 40%, and non-cardiac oversensing 20%). Reprogramming, proper drug therapy, and surgical revision avoided further IAS. Complications requiring surgical revision occurred in 9% of patients, with higher risks in patients with three-incision procedures [hazard ratio (HR) 4.3, 95% confidence interval (95% CI) 0.5-34, P = 0.038] and BMI < 20 (HR 5.1, 95% CI 1-24, P = 0.031). CONCLUSION This multicentre European paediatric registry showed good S-ICD efficacy and safety in young patients. Newer implantation techniques and BMI > 20 showed better outcome.
Collapse
Affiliation(s)
| | - Luc Bruyndonckx
- Department of Paediatric Cardiology, Amsterdam University Medical Centers, Amsterdam, The Netherlands,Laboratory of Experimental Medicine and Paediatrics, University of Antwerp, Antwerp, Belgium
| | - Alice Maltret
- Department of Paediatric Cardiology Hopital Necker-Enfants Malades, Paris, France,Hopital Marie Lannelongue-M3C, GHPSJ, Université Paris Descartes, Paris, France
| | - Roman Gebauer
- Department of Paediatric Cardiology, Heart Centre Leipzig, University of Leipzig, Leipzig, Germany
| | - Joanna Kwiatkowska
- Department of Paediatric Cardiology and Congenital Heart Defects, Medical University of Gdansk, Gdansk, Poland
| | - László Környei
- Gottsegen National Cardiovascular Center, Budapest, Hungary
| | - Sonia Albanese
- Heart Surgery Team, Department of Paediatric Cardiology and Cardiac Surgery, Bambino Gesù Children’s Hospital IRCCS, Rome, Italy
| | - Cristina Raimondo
- Paediatric Cardiology and Cardiac Arrhythmia/Syncope Unit, Department of Paediatric Cardiology and Cardiac Surgery, Bambino Gesù Children’s Hospital IRCCS, Rome, Italy,Department of Paediatric Cardiology Hopital Necker-Enfants Malades, Paris, France
| | - Christian Paech
- Department of Paediatric Cardiology, Heart Centre Leipzig, University of Leipzig, Leipzig, Germany
| | - Maciej Kempa
- Department of Cardiology and Electrotherapy, Medical University of Gdansk, Gdansk, Poland
| | - Gábor Fésüs
- Gottsegen National Cardiovascular Center, Budapest, Hungary
| | - Reinoud E Knops
- Department of Paediatric Cardiology, Amsterdam University Medical Centers, Amsterdam, The Netherlands,Department of Paediatrics, Antwerp University Hospital, Edegem, Belgium
| | - Nico Andreas Blom
- Department of Paediatric Cardiology, Amsterdam University Medical Centers, Amsterdam, The Netherlands,Department of Paediatric Cardiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Fabrizio Drago
- Paediatric Cardiology and Cardiac Arrhythmia/Syncope Unit, Department of Paediatric Cardiology and Cardiac Surgery, Bambino Gesù Children’s Hospital IRCCS, Rome, Italy
| |
Collapse
|
3
|
Silvetti MS, Tamburri I, Campisi M, Saputo FA, Cazzoli I, Cantarutti N, Cicenia M, Adorisio R, Baban A, Ravà L, Drago F. ICD Outcome in Pediatric Cardiomyopathies. J Cardiovasc Dev Dis 2022; 9:jcdd9020033. [PMID: 35200687 PMCID: PMC8875861 DOI: 10.3390/jcdd9020033] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 01/10/2022] [Accepted: 01/17/2022] [Indexed: 02/01/2023] Open
Abstract
Background: Pediatric patients with cardiomyopathies are at risk of malignant arrhythmias and sudden cardiac death (SCD). An ICD may prevent SCD. The aim of this study was to evaluate ICD implantation outcomes, and to compare transvenous and subcutaneous ICDs (S-ICDs) implanted in pediatric patients with cardiomyopathies. Methods: The study is single center and retrospective, and includes pediatric patients with cardiomyopathies who required ICD implantation (2010–2021). Outcomes were recorded for appropriate/inappropriate ICD therapy and surgical complications. Transvenous ICD and S-ICD were compared. Data are presented as median values (25th–75th centiles). Results: Forty-four patients with cardiomyopathies (hypertrophic 39%, arrhythmogenic 32%, dilated 27%, and restrictive 2%) underwent transvenous (52%) and S-ICD (48%) implantation at 14 (12–17) years of age, mostly for primary prevention (73%). The follow-up period was 29 (14–60) months. Appropriate ICD therapies were delivered in 25% of patients, without defibrillation failures. Lower age at implantation and secondary prevention were significant risk factors for malignant ventricular arrhythmias that required appropriate ICD therapies. ICD-related complications were surgical complications (18%) and inappropriate shocks (7%). No significant differences in outcomes were recorded, either when comparing transvenous and S-ICD or comparing the different cardiomyopathies. Conclusions: In pediatric patients with cardiomyopathy, ICD therapy is effective, with a low rate of inappropriate shocks. Neither ICD type (transvenous and S-ICDs) nor the cardiomyopathies subgroup revealed divergent outcomes.
Collapse
Affiliation(s)
- Massimo Stefano Silvetti
- Pediatric Cardiology and Cardiac Arrhythmia/Syncope Unit, Bambino Gesù Children’s Hospital IRCCS, 00165 Rome, Italy; (I.T.); (M.C.); (F.A.S.); (I.C.); (N.C.); (M.C.); (R.A.); (A.B.); (F.D.)
- Correspondence: ; Tel.: +39-06-6859-1
| | - Ilaria Tamburri
- Pediatric Cardiology and Cardiac Arrhythmia/Syncope Unit, Bambino Gesù Children’s Hospital IRCCS, 00165 Rome, Italy; (I.T.); (M.C.); (F.A.S.); (I.C.); (N.C.); (M.C.); (R.A.); (A.B.); (F.D.)
| | - Marta Campisi
- Pediatric Cardiology and Cardiac Arrhythmia/Syncope Unit, Bambino Gesù Children’s Hospital IRCCS, 00165 Rome, Italy; (I.T.); (M.C.); (F.A.S.); (I.C.); (N.C.); (M.C.); (R.A.); (A.B.); (F.D.)
| | - Fabio Anselmo Saputo
- Pediatric Cardiology and Cardiac Arrhythmia/Syncope Unit, Bambino Gesù Children’s Hospital IRCCS, 00165 Rome, Italy; (I.T.); (M.C.); (F.A.S.); (I.C.); (N.C.); (M.C.); (R.A.); (A.B.); (F.D.)
| | - Ilaria Cazzoli
- Pediatric Cardiology and Cardiac Arrhythmia/Syncope Unit, Bambino Gesù Children’s Hospital IRCCS, 00165 Rome, Italy; (I.T.); (M.C.); (F.A.S.); (I.C.); (N.C.); (M.C.); (R.A.); (A.B.); (F.D.)
| | - Nicoletta Cantarutti
- Pediatric Cardiology and Cardiac Arrhythmia/Syncope Unit, Bambino Gesù Children’s Hospital IRCCS, 00165 Rome, Italy; (I.T.); (M.C.); (F.A.S.); (I.C.); (N.C.); (M.C.); (R.A.); (A.B.); (F.D.)
| | - Marianna Cicenia
- Pediatric Cardiology and Cardiac Arrhythmia/Syncope Unit, Bambino Gesù Children’s Hospital IRCCS, 00165 Rome, Italy; (I.T.); (M.C.); (F.A.S.); (I.C.); (N.C.); (M.C.); (R.A.); (A.B.); (F.D.)
| | - Rachele Adorisio
- Pediatric Cardiology and Cardiac Arrhythmia/Syncope Unit, Bambino Gesù Children’s Hospital IRCCS, 00165 Rome, Italy; (I.T.); (M.C.); (F.A.S.); (I.C.); (N.C.); (M.C.); (R.A.); (A.B.); (F.D.)
| | - Anwar Baban
- Pediatric Cardiology and Cardiac Arrhythmia/Syncope Unit, Bambino Gesù Children’s Hospital IRCCS, 00165 Rome, Italy; (I.T.); (M.C.); (F.A.S.); (I.C.); (N.C.); (M.C.); (R.A.); (A.B.); (F.D.)
| | - Lucilla Ravà
- Epidemiology Institute, Bambino Gesù Children’s Hospital IRCCS, 00165 Rome, Italy;
| | - Fabrizio Drago
- Pediatric Cardiology and Cardiac Arrhythmia/Syncope Unit, Bambino Gesù Children’s Hospital IRCCS, 00165 Rome, Italy; (I.T.); (M.C.); (F.A.S.); (I.C.); (N.C.); (M.C.); (R.A.); (A.B.); (F.D.)
| |
Collapse
|
4
|
Frommeyer G, Feder S, Bettin M, Debus V, Köbe J, Reinke F, Uebing A, Eckardt L, Kehl HG. Long-term single-center experience of defibrillator therapy in children and adolescents. Int J Cardiol 2018; 271:105-108. [PMID: 29885825 DOI: 10.1016/j.ijcard.2018.05.130] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Revised: 04/14/2018] [Accepted: 05/31/2018] [Indexed: 11/18/2022]
Abstract
BACKGROUND Implantable cardioverter-defibrillator (ICD) systems are established therapy for prevention of sudden cardiac death. Long-term data on ICD systems in children and adolescents is rare. The present study displays a long-term single-center follow-up of children and adolescents with ICD systems. METHODS AND RESULTS The present study represents a single-center experience of patients younger than 18 years who received an ICD (n = 58). Follow-up data included in-house follow-up as well as examinations of collaborating specialists. Mean age at implantation was 14.0 ± 3.3 years and 33 patients (56.9%) were male. A transvenous ICD system was implanted in 54 patients (93.1%). In 33 patients (56.9%) electrical heart disease or idiopathic ventricular fibrillation represented the underlying condition of ICD implantation. Median follow-up duration was 70 months (45; 94). 3 patients (5.2%) died during the observation period. None of these deaths was associated with ICD failure. Appropriate shocks occurred in 32 patients (55.2%). Inappropriate shock delivery was recorded in 17 patients (29.3%). Supraventricular tachycardia represented the most frequent cause of inappropriate shock delivery (9 patients, 52.9%). T-wave oversensing led to inappropriate shock delivery in 3 patients (17.6%). In 5 patients (29.4%), lead failure caused inappropriate shock delivery. Of note, during follow-up lead failure was reported in 15 patients (25.9%) leading to surgical revision. CONCLUSION ICD therapy in children and adolescents is effective for prevention of sudden cardiac death. The rate of appropriate shock deliveries was significantly higher as compared with large ICD trials. Inappropriate therapies occurred frequently. In particular supraventricular tachycardia, T-wave oversensing and lead failures were responsible for these episodes.
Collapse
Affiliation(s)
- Gerrit Frommeyer
- Department of Cardiology II - Electrophysiology, University of Münster, Münster, Germany.
| | - Sebastian Feder
- Department of Pedriatric Cardiology, University of Münster, Münster, Germany
| | - Markus Bettin
- Department of Cardiology II - Electrophysiology, University of Münster, Münster, Germany
| | - Volker Debus
- Department of Pedriatric Cardiology, University of Münster, Münster, Germany
| | - Julia Köbe
- Department of Cardiology II - Electrophysiology, University of Münster, Münster, Germany
| | - Florian Reinke
- Department of Cardiology II - Electrophysiology, University of Münster, Münster, Germany
| | - Anselm Uebing
- Department of Pedriatric Cardiology, University of Münster, Münster, Germany
| | - Lars Eckardt
- Department of Cardiology II - Electrophysiology, University of Münster, Münster, Germany
| | - Hans Gerd Kehl
- Department of Pedriatric Cardiology, University of Münster, Münster, Germany
| |
Collapse
|
5
|
Müller MJ, Dieks JK, Backhoff D, Schneider HE, Ruschewski W, Tirilomis T, Paul T, Krause U. Efficacy and safety of non-transvenous cardioverter defibrillators in infants and young children. J Interv Card Electrophysiol 2018; 54:151-159. [PMID: 30255451 DOI: 10.1007/s10840-018-0451-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2018] [Accepted: 09/07/2018] [Indexed: 10/28/2022]
Abstract
BACKGROUND Implantable cardioverter defibrillators (ICD) protect from sudden cardiac death (SCD). In infants and young children, ICD implantation and programming is challenging due to small body size, elevated heart rates, and high physical activity. PURPOSE We report our experience applying a non-transvenous ICD (NT-ICD) system to infants and children < 12 years of age and < 45-kg body weight. METHODS Between 07/2004 and 07/2016, NT-ICD had been implanted in 36 patients. Nine out of 36 patients (25%) had NT-ICD implantation for primary and 27/36 (75%) for secondary prevention. Underlying diseases included inherited primary electrical arrhythmogenic diseases (n = 26; 72%), cardiomyopathies (n = 8; 22%), and congenital heart defects (n = 2; 6%). The median (interquartile range) age at implantation was 6 (1.9-8.4) years, and the median body weight was 21.7 (11.2-26.8) kg. Three different NT-ICD implantation techniques had been applied over time: (1) abdominal device/subcutaneous shock coil, (2) abdominal device/pleural shock coil, and (3) subcardiac device/pleural shock coil. RESULTS During median follow-up of 5.2 (2.7-7.2) years, appropriate ICD discharges were documented in 12 (33.3%) and inappropriate shocks in 4 patients (11.1%). In 12/36 individuals (33.3%), a total of 25 surgical revisions were required due to NT-ICD malfunction. Eighteen out of 25 (72%) surgical revisions were necessary in patients with subcutaneous shock coil/abdominal device position. Surgical revisions (3/25, 12%) were significantly reduced (p < 0.001) after modifying the implantation technique to subcardiac device/pleural shock coil. CONCLUSIONS NT-ICD was safe and effective in infants and young children. Appropriate ICD discharges occurred in a considerable number of patients. After modifying the implantation technique, the need for surgical revision could significantly be decreased.
Collapse
Affiliation(s)
- Matthias J Müller
- Department of Pediatric Cardiology and Intensive Care, University Medical Center, Georg August University Goettingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany.
| | - Jana K Dieks
- Department of Pediatric Cardiology and Intensive Care, University Medical Center, Georg August University Goettingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - David Backhoff
- Department of Pediatric Cardiology and Intensive Care, University Medical Center, Georg August University Goettingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - Heike E Schneider
- Department of Pediatric Cardiology and Intensive Care, University Medical Center, Georg August University Goettingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - Wolfgang Ruschewski
- Department of Thoracic, Heart, and Cardiovascular Surgery, University Medical Center, Georg August University Goettingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - Theodor Tirilomis
- Department of Thoracic, Heart, and Cardiovascular Surgery, University Medical Center, Georg August University Goettingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - Thomas Paul
- Department of Pediatric Cardiology and Intensive Care, University Medical Center, Georg August University Goettingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - Ulrich Krause
- Department of Pediatric Cardiology and Intensive Care, University Medical Center, Georg August University Goettingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| |
Collapse
|
6
|
Winkler F, Dave H, Weber R, Gass M, Balmer C. Long-term outcome of epicardial implantable cardioverter-defibrillator systems in children: results justify its preference in paediatric patients. Europace 2017; 20:1484-1490. [DOI: 10.1093/europace/eux284] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2017] [Accepted: 08/14/2017] [Indexed: 11/14/2022] Open
Affiliation(s)
- Florian Winkler
- Departments of Cardiology, Pediatric Heart Centre, University Children‘s Hospital Zurich, Steinwiesstr. 75, Zurich, Switzerland
| | - Hitendu Dave
- Cardiothoracic Surgery, Pediatric Heart Centre, University Children’s Hospital Zurich, Steinwiesstr. 75, Zurich, Switzerland
| | - Roland Weber
- Departments of Cardiology, Pediatric Heart Centre, University Children‘s Hospital Zurich, Steinwiesstr. 75, Zurich, Switzerland
| | - Matthias Gass
- Departments of Cardiology, Pediatric Heart Centre, University Children‘s Hospital Zurich, Steinwiesstr. 75, Zurich, Switzerland
| | - Christian Balmer
- Departments of Cardiology, Pediatric Heart Centre, University Children‘s Hospital Zurich, Steinwiesstr. 75, Zurich, Switzerland
| |
Collapse
|
7
|
Benítez Ramos DB, Cabrera Ortega M, Castro Hevia J, Dorantes Sánchez M, Alemán Fernández AA, Castañeda Chirino O, Cruz Cardentey M, Martínez López F, Falcón Rodríguez R. Electrocardiographic Markers of Appropriate Implantable Cardioverter-Defibrillator Therapy in Young People with Congenital Heart Diseases. Pediatr Cardiol 2017; 38:1663-1671. [PMID: 28871362 DOI: 10.1007/s00246-017-1711-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/22/2017] [Accepted: 08/09/2017] [Indexed: 11/24/2022]
Abstract
Implantable cardioverter-defibrillators (ICDs) are increasingly utilized in patients with congenital heart disease (CHD). Prediction of the occurrence of shocks is important if improved patient selection is desired. The electrocardiogram (ECG) has been the first-line tool predicting the risk of sudden death, but data in CHD patients are lacking. We aim to evaluate the predictive value of electrocardiographic markers of appropriate therapy of ICD in young people with CHD. We conducted a prospective, longitudinal study, in twenty-six CHD patients (mean age 24.7 ± 5.3 years) who underwent first ICD implantation. Forty-two age- and diagnosis-matched controls were recruited. Twelve-lead ECG and 24 h Holter analysis were performed during a mean follow-up of 38.9 months. Data included heart rate, heart rate variability, QRS duration (QRSd), QTc interval and its dispersion, Tpeak-Tend (Tp-Te) interval and its dispersion, presence of fragmented QRS (fQRS), T wave alternans, atrial arrhythmias, and non-sustained ventricular tachycardia. Implant indication was primary prevention in ten cases (38.5%) and secondary prevention in 16 (61.5%). Overall, 17 subjects (65.3%) received at least one appropriate and effective ICD discharge. fQRS was present in 64.7% of cases with ICD therapy compared with patients without events or controls (p < 0.0001). Tp-e and Tp-e dispersion were significantly prolonged in patients with recurrences (113.5 and 37.2 ms) versus patients without ICD discharge (89.6 and 24.1 ms) or controls (72.4 and 19.3 ms) (p < 0.0001 and p < 0.0001, respectively). On univariate Cox regression analysis QRSd (hazard ratio: 1.19 per ms, p = 0.003), QTc dispersion (hazard ratio: 1.57 per ms, p = 0.002), fQRS (hazard ratio: 3.58 p < 0.0001), Tp-e (hazard ratio: 2.27 per ms, p < 0.0001), and Tp-e dispersion (hazard ratio: 4.15 per ms, p < 0.0001), emerged as strong predictors of outcome. On multivariate Cox analysis fQRS, Tp-e and Tp-e dispersion remained in the model. The presence of fQRS, and both Tp-e and Tp-e dispersion are useful ECG tools in daily clinical practice to identify CHD patients at risk for appropriate ICD therapy.
Collapse
MESH Headings
- Adult
- Arrhythmias, Cardiac/diagnosis
- Arrhythmias, Cardiac/etiology
- Arrhythmias, Cardiac/mortality
- Biomarkers
- Cohort Studies
- Death, Sudden, Cardiac/etiology
- Death, Sudden, Cardiac/prevention & control
- Defibrillators, Implantable/adverse effects
- Electrocardiography/methods
- Female
- Follow-Up Studies
- Heart Defects, Congenital/complications
- Heart Defects, Congenital/mortality
- Heart Defects, Congenital/therapy
- Humans
- Longitudinal Studies
- Male
- Predictive Value of Tests
- Proportional Hazards Models
- Prospective Studies
- Risk Factors
- Survival Analysis
- Young Adult
Collapse
Affiliation(s)
- Dunia Bárbara Benítez Ramos
- Department of Pediatric Cardiology, Cardiocentro Pediátrico William Soler, San Francisco e/100 y Perla, Altahabana, Boyeros, Havana, 10800, Cuba.
| | - Michel Cabrera Ortega
- Section of Arrhythmia and Cardiac Pacing, Cardiocentro Pediátrico William Soler, 100 y Perla, Altahabana, Boyeros, Havana, Cuba
| | - Jesús Castro Hevia
- Service of Arrhythmia and Cardiac Pacing, Instituto de Cardiología y Cirugía Cardiovascular, 17 y Paseo, Plaza de la Revolución, Vedado, Havana, Cuba
| | - Margarita Dorantes Sánchez
- Service of Arrhythmia and Cardiac Pacing, Instituto de Cardiología y Cirugía Cardiovascular, 17 y Paseo, Plaza de la Revolución, Vedado, Havana, Cuba
| | - Ailema Amelia Alemán Fernández
- Service of Arrhythmia and Cardiac Pacing, Instituto de Cardiología y Cirugía Cardiovascular, 17 y Paseo, Plaza de la Revolución, Vedado, Havana, Cuba
| | - Osmin Castañeda Chirino
- Service of Arrhythmia and Cardiac Pacing, Instituto de Cardiología y Cirugía Cardiovascular, 17 y Paseo, Plaza de la Revolución, Vedado, Havana, Cuba
| | - Marlenis Cruz Cardentey
- Service of Arrhythmia and Cardiac Pacing, Instituto de Cardiología y Cirugía Cardiovascular, 17 y Paseo, Plaza de la Revolución, Vedado, Havana, Cuba
| | - Frank Martínez López
- Service of Arrhythmia and Cardiac Pacing, Instituto de Cardiología y Cirugía Cardiovascular, 17 y Paseo, Plaza de la Revolución, Vedado, Havana, Cuba
| | - Roylan Falcón Rodríguez
- Service of Arrhythmia and Cardiac Pacing, Instituto de Cardiología y Cirugía Cardiovascular, 17 y Paseo, Plaza de la Revolución, Vedado, Havana, Cuba
| |
Collapse
|
8
|
Garnreiter JM. Inappropriate ICD Shocks in Pediatric and Congenital Heart Disease Patients. J Innov Card Rhythm Manag 2017; 8:2898-2906. [PMID: 32494433 PMCID: PMC7252892 DOI: 10.19102/icrm.2017.081104] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2017] [Accepted: 07/18/2017] [Indexed: 11/06/2022] Open
Abstract
Although implantable cardioverter-defibrillators (ICDs) have proven to be life-saving devices, there are frequent complications associated with their use, especially in the pediatric and congenital heart disease populations. Inappropriate shocks are a particularly frequent complication in these groups. This review discusses the causes and implications of inappropriate ICD shocks, and presents potential interventions that may assist in safely reducing the rates of inappropriate shocks in pediatric and congenital heart disease patients with ICDs.
Collapse
Affiliation(s)
- Jason M Garnreiter
- Department of Pediatrics, Saint Louis University School of Medicine, St. Louis, MO, USA
| |
Collapse
|