1
|
Wang N, Zhang M, Chang Y, Niu N, Guan Y, Ye M, Li C, Tang J. Directly observing alterations of morphology and mechanical properties of living cancer cells with atomic force microscopy. Talanta 2018; 191:461-468. [PMID: 30262086 DOI: 10.1016/j.talanta.2018.09.008] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Revised: 08/29/2018] [Accepted: 09/03/2018] [Indexed: 12/18/2022]
Abstract
Epithelial-mesenchymal transition (EMT) is a biological process during which cells lose their characteristic structure and biochemical properties then adopt typical features of a mesenchymal phenotype. Alterations in the morphology, structure, and mechanical properties of cells during EMT are associated with a series of pathological processes. In this work, atomic force microscopy (AFM) is used for investigating effects of TGF-β1 on morphology and mechanical properties of living bladder cancer cells (T24) during EMT for the first time. High-resolution topography and Young's modulus images of T24 living cell are obtained simultaneously. The results show that TGF-β1 is able to induce EMT, leading to the increased F-actin stress fibers and much higher Young's modulus values of T24 living cells. It reveals that the cytoskeletal-associated cell architecture is closely related to the mechanical dynamics of T24 cells during EMT. This work provides new insights into the changes of cell morphology and mechanical properties during EMT. It enables us to gain a deeper understanding of the growth, development and metastasis of the bladder cancer cell therefore it is of great significance for studying the pathological mechanism of cells at single-cell level.
Collapse
Affiliation(s)
- Nan Wang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, PR China; School of Pharmacy, Hebei Medical University, Shijiazhuang 050017, PR China; University of Chinese Academy of Sciences, Beijing 100049, PR China
| | - Miaomiao Zhang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, PR China; University of Science and Technology of China, Hefei 230026, PR China
| | - Yaqing Chang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, PR China; University of Chinese Academy of Sciences, Beijing 100049, PR China
| | - Niu Niu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, PR China; University of Science and Technology of China, Hefei 230026, PR China
| | - Yanxue Guan
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, PR China; University of Chinese Academy of Sciences, Beijing 100049, PR China
| | - Ming Ye
- Bruker (Beijing) Scientific Technology Co., Ltd, Shanghai 200233, PR China
| | - Chen Li
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, PR China; University of Science and Technology of China, Hefei 230026, PR China
| | - Jilin Tang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, PR China; University of Chinese Academy of Sciences, Beijing 100049, PR China; University of Science and Technology of China, Hefei 230026, PR China.
| |
Collapse
|
2
|
Boccaccio A, Uva AE, Papi M, Fiorentino M, De Spirito M, Monno G. Nanoindentation characterisation of human colorectal cancer cells considering cell geometry, surface roughness and hyperelastic constitutive behaviour. NANOTECHNOLOGY 2017; 28:045703. [PMID: 27981954 DOI: 10.1088/1361-6528/28/4/045703] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Characterisation of the mechanical behaviour of cancer cells is an issue of crucial importance as specific cell mechanical properties have been measured and utilized as possible biomarkers of cancer progression. Atomic force microscopy certainly occupies a prominent place in the field of the mechanical characterisation devices. We developed a hybrid approach to characterise different cell lines (SW620 and SW480) of the human colon carcinoma submitted to nanoindentation measurements. An ad hoc algorithm was written that compares the force-indentation curves experimentally retrieved with those predicted by a finite element model that simulates the nanoindentation process and reproduces the cell geometry and the surface roughness. The algorithm perturbs iteratively the values of the cell mechanical properties implemented in the finite element model until the difference between the experimental and numerical force-indentation curves reaches the minimum value. The occurrence of this indicates that the implemented material properties are very close to the real ones. Different hyperelastic constitutive models, such as Arruda-Boyce, Mooney-Rivlin and Neo-Hookean were utilized to describe the structural behaviour of indented cells. The algorithm was capable of separating, for all the cell lines investigated, the mechanical properties of cell cortex and cytoskeleton. Material properties determined via the algorithm were different with respect to those obtained with the Hertzian contact theory. This demonstrates that factors such as: the cell geometry/anatomy and the hyperelastic constitutive behaviour, which are not contemplated in the Hertz's theory hypotheses, do affect the nanoindentation measurements. The proposed approach represents a powerful tool that, only on the basis of nanoindentation measurements, is capable of characterising material at the subcellular level.
Collapse
Affiliation(s)
- Antonio Boccaccio
- Dipartimento di Meccanica, Matematica e Management, Politecnico di Bari, Bari, I-70126, Italy
| | | | | | | | | | | |
Collapse
|
3
|
Buckley ST, Medina C, Davies AM, Ehrhardt C. Cytoskeletal re-arrangement in TGF-β1-induced alveolar epithelial-mesenchymal transition studied by atomic force microscopy and high-content analysis. NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE 2012; 8:355-64. [DOI: 10.1016/j.nano.2011.06.021] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2010] [Revised: 06/23/2011] [Accepted: 06/28/2011] [Indexed: 12/19/2022]
|
4
|
Crowder SW, Gupta MK, Hofmeister LH, Zachman AL, Sung HJ. Modular polymer design to regulate phenotype and oxidative response of human coronary artery cells for potential stent coating applications. Acta Biomater 2012; 8:559-69. [PMID: 22019760 DOI: 10.1016/j.actbio.2011.10.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2011] [Revised: 09/28/2011] [Accepted: 10/03/2011] [Indexed: 02/05/2023]
Abstract
Polymer properties can be tailored by copolymerizing subunits with specific physico-chemical characteristics. Vascular stent materials require biocompatibility, mechanical strength, and prevention of restenosis. Here we copolymerized poly(ε-caprolactone) (PCL), poly(ethylene glycol) (PEG), and carboxyl-PCL (cPCL) at varying molar ratios and characterized the resulting material properties. We then performed a short-term evaluation of these polymers for their applicability as potential coronary stent coating materials with two primary human coronary artery cell types: smooth muscle cells (HCASMC) and endothelial cells (HCAEC). Changes in proliferation and phenotype were dependent upon intracellular reactive oxygen species (ROS) levels, and 4%PEG-96%PCL-0%cPCL was identified as the most appropriate coating material for this application. After 3days on this substrate HCASMC maintained a healthy contractile phenotype and HCAEC exhibited a physiologically relevant proliferation rate and a balanced redox state. Other test substrates promoted a pathological, synthetic phenotype of HCASMC and/or hyperproliferation of HCAEC. Phenotypic changes of HCASMC appeared to be modulated by the Young's modulus and surface charge of the test substrates, indicating a structure-function relationship that can be exploited for intricate control over vascular cell functions. These data indicate that tailored copolymer properties can direct vascular cell behavior and provide insights for further development of biologically instructive stent coating materials.
Collapse
Affiliation(s)
- Spencer W Crowder
- Department of Biomedical Engineering, Vanderbilt University, VU Station B 351631, 5824 Stevenson Center, Nashville, TN 37235, USA
| | | | | | | | | |
Collapse
|
5
|
Yu SS, Ortega RA, Reagan BW, McPherson JA, Sung HJ, Giorgio TD. Emerging applications of nanotechnology for the diagnosis and management of vulnerable atherosclerotic plaques. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY 2011; 3:620-46. [PMID: 21834059 DOI: 10.1002/wnan.158] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
An estimated 16 million people in the United States have coronary artery disease (CAD), and approximately 325,000 people die annually from cardiac arrest. About two-thirds of unexpected cardiac deaths occur without prior recognition of cardiac disease. A vast majority of these deaths are attributable to the rupture of 'vulnerable atherosclerotic plaques'. Clinically, plaque vulnerability is typically assessed through imaging techniques, and ruptured plaques leading to acute myocardial infarction are treated through angioplasty or stenting. Despite significant advances, it is clear that current imaging methods are insufficiently capable for elucidating plaque composition--which is a key determinant of vulnerability. Further, the exciting improvement in the treatment of CAD afforded by stenting procedures has been buffered by significant undesirable host-implant effects, including restenosis and late thrombosis. Nanotechnology has led to some potential solutions to these problems by yielding constructs that interface with plaque cellular components at an unprecedented size scale. By leveraging the innate ability of macrophages to phagocytose nanoparticles, contrast agents can now be targeted to plaque inflammatory activity. Improvements in nano-patterning procedures have now led to increased ability to regenerate tissue isotropy directly on stents, enabling gradual regeneration of normal, physiologic vascular structures. Advancements in immunoassay technologies promise lower costs for biomarker measurements, and in the near future, may enable the addition of routine blood testing to the clinician's toolbox--decreasing the costs of atherosclerosis-related medical care. These are merely three examples among many stories of how nanotechnology continues to promise advances in the diagnosis and treatment of vulnerable atherosclerotic plaques.
Collapse
Affiliation(s)
- Shann S Yu
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | | | | | | | | | | |
Collapse
|
6
|
Freeman JW, Snowhill PB, Nosher JL. A link between stent radial forces and vascular wall remodeling: the discovery of an optimal stent radial force for minimal vessel restenosis. Connect Tissue Res 2010; 51:314-26. [PMID: 20388019 DOI: 10.3109/03008200903329771] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Coronary and peripheral artery disease (PAD) continue to be primary causes of morbidity and mortality in western nations; percutaneous transluminal angioplasty (PTA) with stenting has become a popular treatment. Unfortunately, restenosis is a significant problem following intravascular stent placement. This study considers the contribution of stent forces in vascular stenosis and remodeling to develop an equation for identifying the optimal stent force. z-Type stents of three radial forces [low (3.4 N), high (16.4 N), and ultrahigh (19.4 N)] were deployed into the iliac arteries of a juvenile porcine model. Vessel diameters were measured before, after deployment, and again at 30 days. At 30 days animals were killed and the vessels fixed in situ. After implantation, there was a significant increase in total thickness and neointimal hyperplasia with increasing stent force. The model for vessel radius and experimental data was in agreement. The model shows that maximum late-term radius is achieved with a stent deployment stress of 480 kPa, which occurs at the end of the stress-strain curve nonlinear domain and beginning of the high-strain collagen domain. The results and calculations suggest that an optimal stent force exists that is subject to the geometry, structure, and mechanics of the target vessel. To achieve maximum late-term dilatation, stents should not produce stress in the vessel wall greater than the end of the transitional domain of the vessel's stress-strain curve. This finding is extremely important for vascular stent development and will be expanded to preliminary vessel wall injury and atherosclerotic models.
Collapse
Affiliation(s)
- Joseph W Freeman
- Virginia Tech-Wake Forest School of Biomedical Engineering and Sciences, Blacksburg, Virginia, USA.
| | | | | |
Collapse
|
7
|
Shi H, Varghese T, Dempsey RJ, Salamat MS, Zagzebski JA. Relationship between ultrasonic attenuation, size and axial strain parameters for ex vivo atherosclerotic carotid plaque. ULTRASOUND IN MEDICINE & BIOLOGY 2008; 34:1666-77. [PMID: 18490099 PMCID: PMC2679642 DOI: 10.1016/j.ultrasmedbio.2008.02.014] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2007] [Revised: 02/19/2008] [Accepted: 02/19/2008] [Indexed: 05/05/2023]
Abstract
Many ultrasonic parameters, primarily related to attenuation and scatterer size, have been used to characterize the composition of atherosclerotic plaque tissue. In this study, we combine elastographic (axial strain ratio) and ultrasonic tissue characterization parameters, namely the attenuation coefficient and a scattering parameter associated with an "equivalent" scatterer size to delineate between fibrous, calcified, and lipidic plaque tissue. We present results obtained from 44 ex vivo atherosclerotic plaque specimens obtained after carotid endarterectomy on human patients. Our results in the frequency range 2.5 - 7.5 MHz indicate that softer plaques (with higher values of the strain ratio) are usually associated with larger equivalent scatterer size estimates (200 - 500 microm) and lower values of the attenuation coefficient slope (<1 dB/cm/MHz). On the other hand, stiffer plaques (with lower strain ratio values) are associated with smaller equivalent scatterer size estimates (100 - 200 microm) and higher values of the attenuation coefficient slope (1 - 3 dB/cm/MHz). These results indicate that ultrasonic tissue characterization and strain parameters have the potential to differentiate between different plaque types. These parameters can be estimated from radio-frequency data acquired under in vivo conditions and may help the clinician decide on appropriate interventional techniques.
Collapse
Affiliation(s)
- Hairong Shi
- Department of Medical Physics, The University of Wisconsin-Madison, Madison, WI 53706, USA
| | | | | | | | | |
Collapse
|
8
|
Kang I, Panneerselvam D, Panoskaltsis VP, Eppell SJ, Marchant RE, Doerschuk CM. Changes in the hyperelastic properties of endothelial cells induced by tumor necrosis factor-alpha. Biophys J 2008; 94:3273-85. [PMID: 18199670 PMCID: PMC2275697 DOI: 10.1529/biophysj.106.099333] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2006] [Accepted: 09/17/2007] [Indexed: 11/18/2022] Open
Abstract
Mechanical properties of living cells can be determined using atomic force microscopy (AFM). In this study, a novel analysis was developed to determine the mechanical properties of adherent monolayers of pulmonary microvascular endothelial cells (ECs) using AFM and finite element modeling, which considers both the finite thickness of ECs and their nonlinear elastic properties, as well as the large strain induced by AFM. Comparison of this model with the more traditional Hertzian model, which assumes linear elastic behavior, small strains, and infinite cell thickness, suggests that the new analysis can predict the mechanical response of ECs during AFM indentation better than Hertz's model, especially when using force-displacement data obtained from large indentations (>100 nm). The shear moduli and distensibility of ECs were greater when using small indentations (<100 nm) compared to large indentations (>100 nm). Tumor necrosis factor-alpha induced changes in the mechanical properties of ECs, which included a decrease in the average shear moduli that occurred in all regions of the ECs and an increase in distensibility in the central regions when measured using small indentations. These changes can be modeled as changes in a chain network structure within the ECs.
Collapse
Affiliation(s)
- Inkyung Kang
- Division of Integrative Biology, Department of Pediatrics, Rainbow Babies and Children's Hospital and Case Western Reserve University, Cleveland, Ohio, USA
| | | | | | | | | | | |
Collapse
|
9
|
O'Loughlin AJC, Byth K. The Stretch–Compression Type of Coronary Artery Movement Predicts the Location of Culprit Lesions Responsible for ST-Segment Elevation Myocardial Infarctions. Heart Lung Circ 2007; 16:265-8. [PMID: 17581785 DOI: 10.1016/j.hlc.2007.02.085] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2006] [Revised: 12/19/2006] [Accepted: 02/05/2007] [Indexed: 10/23/2022]
Abstract
BACKGROUND Prediction of the location of culprit lesions responsible for ST-segment elevation myocardial infarctions may allow for prevention of these events by safe and easily deliverable local therapies. METHODS A retrospective analysis of coronary movement was performed on coronary angiograms of patients who subsequently represented with ST-segment elevation myocardial infarction treated by primary or rescue angioplasty at a single institution. RESULTS Twenty patients were identified. The stretch-compression type of coronary artery movement (CAM) was a statistically significant independent predictor of the segment containing the culprit lesion (odds ratio 6.10, p-value 0.005). CONCLUSIONS The stretch-compression type of coronary artery movement is an independent predictor of the location of culprit lesions responsible for ST-segment elevation myocardial infarctions.
Collapse
Affiliation(s)
- Aiden J C O'Loughlin
- Department of Interventional Cardiology, 300 Pasteur Drive, Room H2103, Stanford University Medical Center, Stanford, CA 94305, USA.
| | | |
Collapse
|
10
|
Schoenhagen P, Nissen SE. Coronary atherosclerosis in diabetic subjects: clinical significance, anatomic characteristics, and identification with in vivo imaging. Cardiol Clin 2004; 22:527-40, vi. [PMID: 15501621 DOI: 10.1016/j.ccl.2004.06.010] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Diabetes mellitus is an endocrine disorder that promotes the development and progression of atherosclerotic coronary disease. As a consequence, cardiovascular disease is the most important cause of morbidity and mortality in diabetics. Early identification and treatment of asymptomatic stages provides the opportunity to prevent cardiovascular end organ complications. Modem clinical imaging modalities allow the assessment of early atherosclerotic changes in coronary arteries; however, prospective evidence that atherosclerosis imaging impacts on clinical outcome is not yet available and future studies are necessary.
Collapse
Affiliation(s)
- Paul Schoenhagen
- The Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| | | |
Collapse
|
11
|
Tajaddini A, Kilpatrick DL, Schoenhagen P, Tuzcu EM, Lieber M, Vince DG. Impact of age and hyperglycemia on the mechanical behavior of intact human coronary arteries: an ex vivo intravascular ultrasound study. Am J Physiol Heart Circ Physiol 2004; 288:H250-5. [PMID: 15331362 DOI: 10.1152/ajpheart.00646.2004] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Despite their advantages, percutaneous coronary interventional procedures are less effective in diabetic patients. Changes in the mechanical properties of vascular walls secondary to long-term hyperglycemia as well as other factors such as age may influence coronary distensibility. This investigation is aimed at deciphering the extent of these effects on distensibility of postmortem human coronary arteries in a controlled manner. Excised human left anterior descending (LAD) coronary arteries were obtained within 24 h postmortem. With the use of intravascular ultrasound, vascular deformation was analyzed at midregions of 51 moderate lesions. Intraluminal pressure was systematically altered using a computerized pressure pump system and monitored by a pressure-sensing guidewire. Distensibility, a normalized compliance term, was defined as the change in lumen area normalized by the initial reference area over a given pressure interval. With the use of multivariate analysis and repeated-measures ANOVA, coronary distensibility was independently influenced by hyperglycemia and age (P < 0.05) through the entire pressure range. Within physiological pressure range, distensibility was significantly reduced with age in nonhyperglycemic coronary specimens (10.55 +/- 4.41 vs. 6.99 +/- 2.45, x10(3) kPa(-1), P = 0.01), whereas the hyperglycemic vessels were stiff even in the younger group (7.90 +/- 5.82 vs. 7.20 +/- 3.36, x10(3) kPa(-1), P = 0.79). Similar results were observed with stiffness index and elastic modulus of the arteries. Hyperglycemia and age independently influenced the distensibility of moderately atherosclerotic LAD coronary arteries. The stiffening with age was overshadowed in the hyperglycemic group by as-yet-undetermined factors.
Collapse
Affiliation(s)
- Azita Tajaddini
- Department of Biomedical Engineering/ND20, The Cleveland Clinic Foundation, 9500 Euclid Ave., Cleveland, OH 44195, USA.
| | | | | | | | | | | |
Collapse
|
12
|
Abstract
Knowledge of blood vessel mechanical properties is fundamental to the understanding of vascular function in health and disease. Analytic results can help physicians in the clinic, both in designing and in choosing appropriate therapies. Understanding the mechanical response of blood vessels to physiologic loads is necessary before ideal therapeutic solutions can be realized. For this reason, blood vessel constitutive models are needed. This article provides a critical review of recent blood vessel constitutive models, starting with a brief overview of the structure and function of arteries and veins, followed by a discussion of experimental techniques used in the characterization of material properties. Current models are classified by type, including pseudoelastic, randomly elastic, poroelastic, and viscoelastic. Comparisons are presented between the various models and existing experimental data. Applications of blood vessel constitutive models are also briefly presented, followed by the identification of future directions in research.
Collapse
Affiliation(s)
- Raymond P Vito
- Woodruff School of Mechanical Engineering, Atlanta, Georgia 30332-0405, USA.
| | | |
Collapse
|