Short-wave infrared fluorescence imaging of near-infrared dyes with robust end-tail emission using a small-animal imaging device. PNAS NEXUS 2023; 2:pgad250. [PMID: 37575672 PMCID: PMC10422693 DOI: 10.1093/pnasnexus/pgad250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 06/07/2023] [Accepted: 07/25/2023] [Indexed: 08/15/2023]
Abstract
Commercially available near-infrared (NIR) dyes, including indocyanine green (ICG), display an end-tail of the fluorescence emission spectrum detectable in the short-wave infrared (SWIR) window. Imaging methods based on the second NIR spectral region (1,000-1,700 nm) are gaining interest within the biomedical imaging community due to minimal autofluorescence and scattering, allowing higher spatial resolution and depth sensitivity. Using a SWIR fluorescence imaging device, the properties of ICG vs. heptamethine cyanine dyes with emission >800 nm were evaluated using tissue-simulating phantoms and animal experiments. In this study, we tested the hypothesis that an increased rigidity of the heptamethine chain may increase the SWIR imaging performance due to the bathochromic shift of the emission spectrum. Fluorescence SWIR imaging of capillary plastic tubes filled with dyes was followed by experiments on healthy animals in which a time series of fluorescence hindlimb images were analyzed. Our findings suggest that higher spatial resolution can be achieved even at greater depths (>5 mm) or longer wavelengths (>1,100 nm), in both tissue phantoms and animals, opening the possibility to translate the SWIR prototype toward clinical application.
Collapse
|
2
|
Impact of Surgical Lights on the Performance of Fluorescence-Guided Surgery Systems: A Pilot Study. Animals (Basel) 2023; 13:2363. [PMID: 37508142 PMCID: PMC10376740 DOI: 10.3390/ani13142363] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 07/16/2023] [Accepted: 07/18/2023] [Indexed: 07/30/2023] Open
Abstract
Fluorescence-guided surgery can aid in the intraoperative visualization of target tissues, with promising applications in human and veterinary surgical oncology. The aim of this study was to evaluate the performances of two fluoresce camera systems, IC-FlowTM and VisionsenseTM VS3 Iridum, for the detection of two non-targeted (ICG and IRDye-800) and two targeted fluorophores (AngiostampTM and FAP-Cyan) under different room light conditions, including ambient light, new generation LED, and halogen artificial light sources, which are commonly used in operating theaters. Six dilutions of the fluorophores were imaged in phantom kits using the two camera systems. The limit of detection (LOD) and mean signal-to-background ratio (mSBR) were determined. The highest values of mSBR and a lower LOD were obtained in dark conditions for both systems. Under room lights, the capabilities decreased, but the mSBR remained greater than 3 (=clearly detectable signal). LOD and mSBR worsened under surgical lights for both camera systems, with a greater impact from halogen bulbs on VisionsenseTM VS3 Iridium and of the LED lights on IC-Flow due to a contribution of these lights in the near-infrared spectrum. When considering implementing FGS into the clinical routine, surgeons should cautiously evaluate the spectral contribution of the lights in the operating theater.
Collapse
|
3
|
Fluorescence guidance improves the accuracy of radiological imaging-guided surgical navigation. J Surg Oncol 2023; 127:490-500. [PMID: 36285723 PMCID: PMC10176708 DOI: 10.1002/jso.27128] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 09/08/2022] [Accepted: 09/24/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND Imaging-based navigation technologies require static referencing between the target anatomy and the optical sensors. Imaging-based navigation is therefore well suited to operations involving bony anatomy; however, these technologies have not translated to soft-tissue surgery. We sought to determine if fluorescence imaging complement conventional, radiological imaging-based navigation to guide the dissection of soft-tissue phantom tumors. METHODS Using a human tissue-simulating model, we created tumor phantoms with physiologically accurate optical density and contrast concentrations. Phantoms were dissected using all possible combinations of computed tomography (CT), magnetic resonance, and fluorescence imaging; controls were included. The data were margin accuracy, margin status, tumor spatial alignment, and dissection duration. RESULTS Margin accuracy was higher for combined navigation modalities compared to individual navigation modalities, and accuracy was highest with combined CT and fluorescence navigation (p = 0.045). Margin status improved with combined CT and fluorescence imaging. CONCLUSIONS At present, imaging-based navigation has limited application in guiding soft-tissue tumor operations due to its inability to compensate for positional changes during surgery. This study indicates that fluorescence guidance enhances the accuracy of imaging-based navigation and may be best viewed as a synergistic technology, rather than a competing one.
Collapse
|
4
|
Identification of a Suitable Untargeted Agent for the Clinical Translation of ABY-029 Paired-Agent Imaging in Fluorescence-Guided Surgery. Mol Imaging Biol 2023; 25:97-109. [PMID: 34642897 PMCID: PMC9413473 DOI: 10.1007/s11307-021-01642-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Revised: 08/05/2021] [Accepted: 08/12/2021] [Indexed: 11/24/2022]
Abstract
PURPOSE Non-specific uptake and retention of molecular targeted agents and heterogeneous tissue optical properties diminish the ability to differentiate between tumor and normal tissues using molecular targeted fluorescent agents. Paired-agent imaging (PAI) can increase the diagnostic ability to detect tumor tissue by mitigating these non-specific effects and providing true molecular contrast by co-administration of an untargeted control imaging agent with a targeted agent. This study evaluates the suitability of available clinically translatable untargeted agents for the translation of PAI in fluorescence-guided surgery using an affibody-based targeted imaging agent (ABY-029). EXPERIMENTAL DESIGN: Three untargeted agents that fluoresce near 700 nm and exhibit good clinical safety profiles (methylene blue, IRDye 700DX, and IRDye 680LT) were tested in combination with the clinically tested IRDye 800CW-labeled anti-epidermal growth factor receptor (EGFR) affibody molecule, ABY-029 (eIND 122,681). Properties of the untargeted agent important for human use and integrity of PAI were tested: (1) plasma protein binding; (2) fluorescence signal linearity in in vitro whole blood dilution; (3) in vivo pharmacokinetic matching to targeted agent in negative control tissue; and (4) in vivo diagnostic accuracy of PAI vs single agent imaging (SAI) of ABY-029 alone in orthotopic oral head and neck squamous cell carcinomas. RESULTS IRDye 680LT outperformed IRDye 700DX and methylene blue with the highest signal linearity (R2 = 0.9998 ± 0.0002, 0.9995 ± 0.0004, 0.91 ± 0.02, respectively), the highest fluorescence yield in whole blood at 1 μM (104.42 ± 0.05, 103.68 ± 0.09, 101.9 ± 0.2, respectively), and the most closely matched ABY-029 pharmacokinetics in EGFR-negative tissues (binding potential error percentage = 0.31% ± 0.37%, 10.25% ± 1.30%, and 8.10% ± 5.37%, respectively). The diagnostic ability of PAI with ABY-029 and IRDye 680LT outperformed conventional SAI with an area-under-the-receiver-operating-characteristic curve (AUC) value of 0.964 vs. 0.854, and 0.978 vs. 0.925 in the Odyssey scanning system and Pearl wide field imaging system, respectively. CONCLUSION PAI is a highly promising methodology for increasing detection of tumors in fluorescence-guided surgery. Although not yet clinically approved, IRDye 680LT demonstrates promise as an untargeted agent when paired with ABY-029. The clinical translation of PAI to maximize tumor excision, while minimizing normal tissue removal, could improve both patient survival and life quality.
Collapse
|
5
|
Current and Future Applications of Fluorescence Guidance in Orthopaedic Surgery. Mol Imaging Biol 2023; 25:46-57. [PMID: 36447084 PMCID: PMC10106269 DOI: 10.1007/s11307-022-01789-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 11/01/2022] [Accepted: 11/16/2022] [Indexed: 12/03/2022]
Abstract
Fluorescence-guided surgery (FGS) is an evolving field that seeks to identify important anatomic structures or physiologic phenomena with helpful relevance to the execution of surgical procedures. Fluorescence labeling occurs generally via the administration of fluorescent reporters that may be molecularly targeted, enzyme-activated, or untargeted, vascular probes. Fluorescence guidance has substantially changed care strategies in numerous surgical fields; however, investigation and adoption in orthopaedic surgery have lagged. FGS shows the potential for improving patient care in orthopaedics via several applications including disease diagnosis, perfusion-based tissue healing capacity assessment, infection/tumor eradication, and anatomic structure identification. This review highlights current and future applications of fluorescence guidance in orthopaedics and identifies key challenges to translation and potential solutions.
Collapse
|
6
|
Performance of two clinical fluorescence imaging systems with different targeted and non-targeted near-infrared fluorophores: a cadaveric explorative study. Front Vet Sci 2023; 10:1091842. [PMID: 37138917 PMCID: PMC10149874 DOI: 10.3389/fvets.2023.1091842] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Accepted: 03/27/2023] [Indexed: 05/05/2023] Open
Abstract
Introduction Near-infrared (NIR) fluorescence-guided surgery is increasingly utilized in humans and pets. As clinical imaging systems are optimized for Indocyanine green (ICG) detection, the usage of targeted dyes necessitates the validation of these systems for each dye. We investigated the impact of skin pigmentation and tissue overlay on the sensitivity of two NIR cameras (IC-FlowTM, VisionsenseTM VS3 Iridum) for the detection of non-targeted (ICG, IRDye800) and targeted (AngiostampTM, FAP-Cyan) NIR fluorophores in an ex vivo big animal model. Methods We quantitatively measured the limit of detection (LOD) and signal-to-background ratio (SBR) and implemented a semi-quantitative visual score to account for subjective interpretation of images by the surgeon. Results VisionsenseTM VS3 Iridum outperformed IC-FlowTM in terms of LOD and SBR for the detection of all dyes except FAP-Cyan. Median SBR was negatively affected by skin pigmentation and tissue overlay with both camera systems. Level of agreement between quantitative and semi-quantitative visual score and interobserver agreement were better with VisionsenseTM VS3 Iridum. Conclusion The overlay of different tissue types and skin pigmentation may negatively affect the ability of the two tested camera systems to identify nanomolar concentrations of targeted-fluorescent dyes and should be considered when planning surgical applications.
Collapse
|
7
|
Validation of a surgical training model containing indocyanine green for near‐infrared fluorescence imaging. Laryngoscope Investig Otolaryngol 2022; 7:1011-1017. [PMID: 36000046 PMCID: PMC9392384 DOI: 10.1002/lio2.858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 05/29/2022] [Accepted: 06/20/2022] [Indexed: 11/26/2022] Open
Abstract
Objective To determine the efficacy of a surgical training model for fluorescence‐guided cancer surgery and validate its utility to detect any residual tumors after tumor resection using electrocautery. Methods We developed surgical training models containing indocyanine green (ICG) for near‐infrared (NIR) fluorescence imaging using a root vegetable organic material (konjac). After the fluorescence assessment for the models, the surgical simulation for fluorescence‐guided cancer surgery using electrocautery was performed. ICG‐containing tumors were divided into two surgical groups: “Enucleation” (removal of the entire visible tumor) and “Complete resection” (removal of the tumor with an appropriate 5‐mm surgical margin). Results All 12 ICG‐containing tumors were clearly visible from the normal view but not from the flipped view. The tumor resection time was significantly longer in the “Complete resection” group than in the “Enucleation” group (p < .001). The ICG‐containing tumors showed a high tumor‐to background ratio from the normal (average = 45.8) and flipped (average = 19.2) views, indicating that the models including ICG‐containing tumors were useful for a surgical simulation in fluorescence‐guided surgery. The average mean fluorescence intensity of the wound bed was significantly higher in the “Enucleation” group than in the “Complete resection” group (p < .01). No decrease in fluorescence signal was found in the wound bed even at 2 days postresection. Conclusion Our surgical training model containing a fluorescent agent is safe, inexpensive, not harmful for humans, and easy to dispose after use. Our model would be beneficial for surgeons to learn NIR fluorescence imaging and to accelerate fluorescence‐guided cancer surgery into clinical application.
Collapse
|
8
|
Criteria for the design of tissue-mimicking phantoms for the standardization of biophotonic instrumentation. Nat Biomed Eng 2022; 6:541-558. [PMID: 35624150 DOI: 10.1038/s41551-022-00890-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2020] [Accepted: 02/07/2022] [Indexed: 01/08/2023]
Abstract
A lack of accepted standards and standardized phantoms suitable for the technical validation of biophotonic instrumentation hinders the reliability and reproducibility of its experimental outputs. In this Perspective, we discuss general criteria for the design of tissue-mimicking biophotonic phantoms, and use these criteria and state-of-the-art developments to critically review the literature on phantom materials and on the fabrication of phantoms. By focusing on representative examples of standardization in diffuse optical imaging and spectroscopy, fluorescence-guided surgery and photoacoustic imaging, we identify unmet needs in the development of phantoms and a set of criteria (leveraging characterization, collaboration, communication and commitment) for the standardization of biophotonic instrumentation.
Collapse
|
9
|
Receptor-Targeted Fluorescence-Guided Surgery With Low Molecular Weight Agents. Front Oncol 2021; 11:674083. [PMID: 34277418 PMCID: PMC8279813 DOI: 10.3389/fonc.2021.674083] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Accepted: 05/10/2021] [Indexed: 12/16/2022] Open
Abstract
Cancer surgery remains the primary treatment option for most solid tumors and can be curative if all malignant cells are removed. Surgeons have historically relied on visual and tactile cues to maximize tumor resection, but clinical data suggest that relapse occurs partially due to incomplete cancer removal. As a result, the introduction of technologies that enhance the ability to visualize tumors in the operating room represents a pressing need. Such technologies have the potential to revolutionize the surgical standard-of-care by enabling real-time detection of surgical margins, subclinical residual disease, lymph node metastases and synchronous/metachronous tumors. Fluorescence-guided surgery (FGS) in the near-infrared (NIRF) spectrum has shown tremendous promise as an intraoperative imaging modality. An increasing number of clinical studies have demonstrated that tumor-selective FGS agents can improve the predictive value of fluorescence over non-targeted dyes. Whereas NIRF-labeled macromolecules (i.e., antibodies) spearheaded the widespread clinical translation of tumor-selective FGS drugs, peptides and small-molecules are emerging as valuable alternatives. Here, we first review the state-of-the-art of promising low molecular weight agents that are in clinical development for FGS; we then discuss the significance, application and constraints of emerging tumor-selective FGS technologies.
Collapse
|
10
|
EGFR-targeted intraoperative fluorescence imaging detects high-grade glioma with panitumumab-IRDye800 in a phase 1 clinical trial. Theranostics 2021; 11:7130-7143. [PMID: 34158840 PMCID: PMC8210618 DOI: 10.7150/thno.60582] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 04/24/2021] [Indexed: 12/12/2022] Open
Abstract
Rationale: First-line therapy for high-grade gliomas (HGGs) includes maximal safe surgical resection. The extent of resection predicts overall survival, but current neuroimaging approaches lack tumor specificity. The epidermal growth factor receptor (EGFR) is a highly expressed HGG biomarker. We evaluated the safety and feasibility of an anti-EGFR antibody, panitumuab-IRDye800, at subtherapeutic doses as an imaging agent for HGG. Methods: Eleven patients with contrast-enhancing HGGs were systemically infused with panitumumab-IRDye800 at a low (50 mg) or high (100 mg) dose 1-5 days before surgery. Near-infrared fluorescence imaging was performed intraoperatively and ex vivo, to identify the optimal tumor-to-background ratio by comparing mean fluorescence intensities of tumor and histologically uninvolved tissue. Fluorescence was correlated with preoperative T1 contrast, tumor size, EGFR expression and other biomarkers. Results: No adverse events were attributed to panitumumab-IRDye800. Tumor fragments as small as 5 mg could be detected ex vivo and detection threshold was dose dependent. In tissue sections, panitumumab-IRDye800 was highly sensitive (95%) and specific (96%) for pathology confirmed tumor containing tissue. Cellular delivery of panitumumab-IRDye800 was correlated to EGFR overexpression and compromised blood-brain barrier in HGG, while normal brain tissue showed minimal fluorescence. Intraoperative fluorescence improved optical contrast in tumor tissue within and beyond the T1 contrast-enhancing margin, with contrast-to-noise ratios of 9.5 ± 2.1 and 3.6 ± 1.1, respectively. Conclusions: Panitumumab-IRDye800 provided excellent tumor contrast and was safe at both doses. Smaller fragments of tumor could be detected at the 100 mg dose and thus more suitable for intraoperative imaging.
Collapse
|
11
|
Rapid (FLASH-FLIM) imaging of protoporphyrin IX in a lipid mixture using a CMOS based widefield fluorescence lifetime imaging camera in real time for margin demarcation applications. Methods Appl Fluoresc 2020; 9. [PMID: 32992309 DOI: 10.1088/2050-6120/abbcc6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Accepted: 09/29/2020] [Indexed: 01/23/2023]
Abstract
The fluorescence from protoporphyrin IX (PpIX) has been employed to characterise cellular activity and assist in the visualisation of tumour cells. Its formation can be induced by 5-aminolevulonic acid (5-ALA) which is metabolised by tumour cells to form PpIX. The PpIX is localised within the cells, rather than spreading into the vascular system. This, plus its photophysics, exhibits potential in photodynamic therapy. Hence its study and the ability to rapidly image its localisation is of importance, especially in the field of fluorescence guided surgery. This has led to investigations using tissue phantoms and widefield intensity imaging. Aggregation or the presence of photoproducts can alter PpIX emission, which has implications using widefield imaging and a broad wavelength range detection. The use of the fluorescence lifetime imaging (FLIM) is therefore advantageous as it can distinguish between the emissive species as they exhibit different fluorescence lifetimes. Here we use PpIX in a construct consisting of lipid mixture (Intralipid), employed to simulate fat content and optical scattering, in a gellan gum matrix. PpIX in intralipid in aqueous solution was injected into the gellan host to form inclusions. The samples are imaged using commercial widefield TCSPC camera based on a sensor chip with 192 x 128 pixels. Each pixel contains both detection and photon timing enabling the Fluorescence Lifetime Acquisition by Simultaneous Histogramming (FLASH). This "FLASH-FLIM" approach enables widefield fluorescence lifetime images, displayed in real time to be acquired, which has potential for use in visualising tumour boundaries.
Collapse
|
12
|
Dual-agent fluorescent labeling of soft-tissue sarcomas improves the contrast based upon targeting both interstitial and cellular components of the tumor milieu. J Surg Oncol 2020; 122:1711-1720. [PMID: 32885452 DOI: 10.1002/jso.26190] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Accepted: 08/14/2020] [Indexed: 12/20/2022]
Abstract
BACKGROUND Current practices for fluorescence-guided cancer surgery utilize a single fluorescent agent, but homogeneous distribution throughout the tumor is difficult to achieve. We hypothesize that administering a perfusion and a molecular-targeted agent at their optimal administration-to-imaging time will improve whole-tumor contrast. EXPERIMENTAL DESIGN Mice bearing subcutaneous xenograft human synovial sarcomas were administered indocyanine green (ICG) (3 mg/kg) or ABY-029 (48.7 μg/kg)-an epidermal growth factor receptor-targeted Affibody molecule-alone or in combination. Fluorescence contrast and signal distribution were compared between treatment groups. Two commercial fluorescence imaging systems were tested for simultaneous imaging of ICG and ABY-029. RESULTS ABY-029 has a moderate positive correlation with viable tumor (ρ = 0.2 ± 0.4), while ICG demonstrated a strong negative correlation (ρ = -0.6 ± 0.1). The contrast-to-variance ratio was highest in the ABY-029 +ICG (2.5 ± 0.8), compared to animals that received ABY-029 (2.3 ± 0.8) or ICG (2.0 ± 0.5) alone. Moreover, the combination of ABY-029 + ICG minimizes the correlation between viable tumor and fluorescence intensity (ρ = -0.1 ± 0.2) indicating the fluorescence signal distribution is more homogeneous throughout the tumor milieu. CONCLUSION Dual-agent imaging utilizing a single channel in a commercial fluorescence-guided imaging system tailored for IRDye 800CW is a promising method to increase tumor contrast in a clinical setting.
Collapse
|
13
|
Probe-based fluorescence dosimetry of an antibody-dye conjugate to identify head and neck cancer as a first step to fluorescence-guided tissue preselection for pathological assessment. Head Neck 2020; 42:59-66. [PMID: 31571335 DOI: 10.1002/hed.25964] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Revised: 08/24/2019] [Accepted: 09/06/2019] [Indexed: 01/28/2023] Open
Abstract
BACKGROUND Despite the rapid growth of fluorescence imaging, accurate sampling of tissue sections remains challenging. Development of novel technologies to improve intraoperative assessment of tissue is needed. METHODS A novel contact probe-based fluorescence dosimeter device, optimized for IRDye800CW quantification, was developed. After evaluation of the device in a phantom setup, its clinical value was defined ex vivo in patients with head and neck squamous cell carcinoma who received panitumumab-IRDye800CW. RESULTS Ten patients were enrolled with a total of 216 data points obtained. Final histopathology showed tumor in 119 spots and normal tissue in 97 spots. Fluorescence-to-excitation ratios in tumor tissue were more than three times higher than those in normal tissue. The area under the curve was 0.86 (95% CI: 0.81-0.91) for tumor detection. CONCLUSIONS Fluorescence-guided tissue preselection using a fluorescence dosimeter could have substantial impact on tissue sampling for frozen section analysis and potentially reduce sampling errors.
Collapse
|
14
|
Intraoperative Tumor Assessment Using Real-Time Molecular Imaging in Head and Neck Cancer Patients. J Am Coll Surg 2019; 229:560-567.e1. [PMID: 31568855 DOI: 10.1016/j.jamcollsurg.2019.09.007] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Revised: 08/14/2019] [Accepted: 09/03/2019] [Indexed: 10/25/2022]
Abstract
BACKGROUND In head and neck cancer, surgical resection using primarily visual and tactile feedback is considered the gold standard for solid tumors. Due to high numbers of tumor-involved surgical margins, which are directly correlated to poor clinical outcomes, intraoperative optical imaging trials have rapidly proliferated over the past 5 years. However, few studies report on intraoperative in situ imaging data that could support surgical resection. To demonstrate the clinical application of in situ surgical imaging, we report on the imaging data that are directly (ie in real-time) available to the surgeon. STUDY DESIGN Fluorescence intensities and tumor-to-background ratios (TBRs) were determined from the intraoperative imaging data-the view as seen by the surgeon during tumor resection-of 20 patients, and correlated to patient and tumor characteristics including age, sex, tumor site, tumor size, histologic differentiation, and epidermal growth factor receptor (EGFR) expression. Furthermore, different lighting conditions in regard to surgical workflow were evaluated. RESULTS Under these circumstances, intraoperative TBRs of the primary tumors averaged 2.2 ± 0.4 (range 1.5 to 2.9). Age, sex, tumor site, and tumor size did not have a significant effect on open-field intraoperative molecular imaging of the primary tumors (p > 0.05). In addition, variation in EGFR expression levels or the presence of ambient light did not seem to alter TBRs. CONCLUSIONS We present the results of successful in situ intraoperative imaging of primary tumors alongside the optimal conditions with respect to both molecular image acquisition and surgical workflow. This study illuminates the potentials of open-field molecular imaging to assist the surgeon in achieving successful cancer removal.
Collapse
|
15
|
Measuring microdose ABY-029 fluorescence signal in a primary human soft-tissue sarcoma resection. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2019; 10862. [PMID: 31595101 DOI: 10.1117/12.2510935] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Microdose administration of ABY-029, an anti-epidermal growth factor receptor Affibody molecule conjugated to IRDye 800CW, is being studied in a Phase 0 trial for resection of soft-tissue sarcomas. The excised tissue of a single patient in the microdose administration group was imaged with both a wide-field fluorescence surgical system and a flat-bed scanning fluorescence imaging system. Here the resultant fluorescence from a breadloaf section of the primary tumor specimen and six region-specific tissue samples collected from that breadloaf are compared using these two imaging systems - a flatbed, black-box, fluorescence scanning system, the Odyssey CLx, and a open-air, wide-field, pre-clinical surgical imaging system, the Solaris. Florescence signal is compared using a variety of methods including: mean, standard deviation, variance, tumor-to-background ratio, biological-variance ratio, and contrast-to-noise ratio. The images produced from the Odyssey scanner have higher signal variance but more accurately represent the EGFR expression in small tissue sections. The Solaris system has higher depth sensitivity and volume averaging, and as such has lower signal variation and higher contrast-to-noise ratio.
Collapse
|
16
|
Preclinical imaging of epidermal growth factor receptor with ABY-029 in soft-tissue sarcoma for fluorescence-guided surgery and tumor detection. J Surg Oncol 2019; 119:1077-1086. [PMID: 30950072 DOI: 10.1002/jso.25468] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Revised: 02/26/2019] [Accepted: 03/14/2019] [Indexed: 12/11/2022]
Abstract
BACKGROUND AND OBJECTIVES Fluorescence-guided surgery using epidermal growth factor receptor (EGFR) targeting has been performed successfully in clinical trials using a variety of fluorescent agents. We investigate ABY-029 (anti-EGFR Affibody® molecule labeled with IRDye 800CW) compared with a small-molecule perfusion agent, IRDye 700DX carboxylate, in a panel of soft-tissue sarcomas with varying levels of EGFR expression and vascularization. METHODS Five xenograft soft-tissue sarcoma cell lines were implanted into immunosuppressed mice. ABY-029 and IRDye 700DX were each administered at 4.98 μM. Fluorescence from in vivo and ex vivo (fresh and formalin-fixed) fixed tissues were compared. The performance of three fluorescence imaging systems was assessed for ex vivo tissues. RESULTS ABY-029 is retained longer within tumor tissue and achieves higher tumor-to-background ratios both in vivo and ex vivo than IRDye 700DX. ABY-029 fluorescence is less susceptible to formalin fixation than IRDye 700DX, but both agents have disproportional signal loss in a variety of tissues. The Pearl Impulse provides the highest contrast-to-noise ratio, but all systems have individual advantages. CONCLUSIONS ABY-029 demonstrates promise to assist in wide local excision of soft-tissue sarcomas. Further clinical evaluation of in situ or freshly excised ex vivo tissues using fluorescence imaging systems is warranted.
Collapse
|
17
|
Comparison of detection sensitivity of near infrared (NIR) surgical imaging systems using a connective tissue phantom model. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2019; 10862. [PMID: 32296255 DOI: 10.1117/12.2510650] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Many tumors for which fluorescence guided surgery (FGS) has been developed are surface tumors, where direct visualization by the surgeon is straightforward. On the other hand, cancers such as soft-tissue sarcomas, are present at a subsurface level. Resection of these sub-surface tumors is performed using 'wide local excision' where a single, complete mass is removed with an intact zone of normal tissue (~ 1 cm 'margin'). We used a phantom model for sarcoma with near infrared fluorophore IRDye800 CW that defined different tissue properties. We compare the detection sensitivity of two commercially available near infrared (NIR) surgical imaging systems, Solaris (Perkin Elmer) and SPY PHI (Novadaq) using the phantom models of sarcoma. We also determine targeted fluorescence signal on both systems for blinded surgical phantom dissection by a surgeon. The fluorescence intensities are higher for Solaris than for SPY-PHI. On average, the fluorescence increased with an increase in intralipid concentration and decreased with an increase in blood concentration. The depth of imaging was higher for Solaris than for SPY PHI. Using the target values, the surgeon successfully dissected all phantoms using Solaris. Using fat phantoms for SPY PHI, the surgeon cut through four out of the total. Further improvement in FGS will improve cancer recurrence and morbidity.
Collapse
|
18
|
Rapid, non-invasive fluorescence margin assessment: Optical specimen mapping in oral squamous cell carcinoma. Oral Oncol 2018; 88:58-65. [PMID: 30616798 DOI: 10.1016/j.oraloncology.2018.11.012] [Citation(s) in RCA: 61] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2018] [Revised: 11/04/2018] [Accepted: 11/07/2018] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Surgical resection remains the primary treatment for the majority of solid tumors. Despite efforts to obtain wide margins, close or positive surgical margins (<5 mm) are found in 15-30% of head and neck cancer patients. Obtaining negative margins requires immediate, intraoperative feedback of margin status. To this end, we propose optical specimen mapping of resected tumor specimens immediately after removal. MATERIALS AND METHODS A first-in-human pilot study was performed in patients (n = 8) after infusion of fluorescently labeled antibody, panitumumab-IRDye800 to allow surgical mapping of the tumor specimen. Patients underwent standard of care surgical resection for head and neck squamous cell carcinoma (HNSCC). Optical specimen mapping was performed on the primary tumor specimen and correlated with pathological findings after tissue processing. RESULTS Optical mapping of the specimen had a 95% sensitivity and 89% specificity to detect cancer within 5 mm (n = 160) of the cut surface. To detect tumor within 2 mm of the specimen surface, the sensitivity of optical specimen mapping was 100%. The maximal observed penetration depth of panitumumab-IRDye800 through human tissue in our study was 6.3 mm. CONCLUSION Optical specimen mapping is a highly sensitive and specific method for evaluation of margins within <5 mm of the tumor mass in HNSCC specimens. This technology has potentially broad applications for ensuring adequate tumor resection and negative margins in head and neck cancers.
Collapse
|
19
|
Correcting Cherenkov light attenuation in tissue using spatial frequency domain imaging for quantitative surface dosimetry during whole breast radiation therapy. JOURNAL OF BIOMEDICAL OPTICS 2018; 24:1-10. [PMID: 30415511 PMCID: PMC6228320 DOI: 10.1117/1.jbo.24.7.071609] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2018] [Accepted: 10/24/2018] [Indexed: 05/08/2023]
Abstract
Imaging Cherenkov emission during radiotherapy permits real-time visualization of external beam delivery on superficial tissue. This signal is linear with absorbed dose in homogeneous media, indicating potential for quantitative dosimetry. In humans, the inherent heterogeneity of tissue optical properties (primarily from blood and skin pigment) distorts the linearity between detected Cherenkov signal and absorbed dose. We examine the potential to correct for superficial vasculature using spatial frequency domain imaging (SFDI) to map tissue optical properties for large fields of view. In phantoms, applying intensity corrections to simulate blood vessels improves Cherenkov image (CI) negative contrast by 24% for a vessel 1.9-mm-in diameter. In human trials, SFDI and CI are acquired for women undergoing whole breast radiotherapy. Applied corrections reduce heterogeneity due to vasculature within the sampling limits of the SFDI from a 22% difference as compared to the treatment plan, down to 6% in one region and from 14% down to 4% in another region. The optimal use for this combined imaging system approach is to correct for small heterogeneities such as superficial blood vessels or for interpatient variations in blood/melanin content such that the corrected CI more closely represents the surface dose delivered.
Collapse
|
20
|
Correcting for targeted and control agent signal differences in paired-agent molecular imaging of cancer cell-surface receptors. JOURNAL OF BIOMEDICAL OPTICS 2018; 23:1-11. [PMID: 29931837 PMCID: PMC6013418 DOI: 10.1117/1.jbo.23.6.066004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2018] [Accepted: 05/31/2018] [Indexed: 05/05/2023]
Abstract
Paired-agent kinetic modeling protocols provide one means of estimating cancer cell-surface receptors with in vivo molecular imaging. The protocols employ the coadministration of a control imaging agent with one or more targeted imaging agent to account for the nonspecific uptake and retention of the targeted agent. These methods require the targeted and control agent data be converted to equivalent units of concentration, typically requiring specialized equipment and calibration, and/or complex algorithms that raise the barrier to adoption. This work evaluates a kinetic model capable of correcting for targeted and control agent signal differences. This approach was compared with an existing simplified paired-agent model (SPAM), and modified SPAM that accounts for signal differences by early time point normalization of targeted and control signals (SPAMPN). The scaling factor model (SPAMSF) outperformed both SPAM and SPAMPN in terms of accuracy and precision when the scale differences between targeted and imaging agent signals (α) were not equal to 1, and it matched the performance of SPAM for α = 1. This model could have wide-reaching implications for quantitative cancer receptor imaging using any imaging modalities, or combinations of imaging modalities, capable of concurrent detection of at least two distinct imaging agents (e.g., SPECT, optical, and PET/MR).